This document is a table of contents for construction specifications for repair and renovation work at Dormitory 655 at Malmstrom Air Force Base in Montana. Key details include mechanical, electrical, plumbing and architectural work across three floors, with demolition, renovation and new construction plans. Divisions of work include selective demolition, structural steel, interior finishes, exterior insulation and finishes, doors and windows, HVAC, plumbing, fire alarm and mass notification systems. The project scope also involves concrete paving, with mechanical, electrical and plumbing demolition and renovation plans provided for each floor. Related drawings provide additional information on existing conditions, proposed renovations and details. The solicitation number listed is for an upcoming multiple award task order contract through the Department of the Air Force Global Strike Command for construction services at Malmstrom AFB.
Amended Table of Contents for Specifications.
View the file
Other files for this federal contract opportunity
Show all 41
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 01 FA4626-18-R-0030
Repair Dormitory 655
NZAS 04-1042
REPAIR DORMITORY 655
MALMSTROM AIR FORCE BASE, MONTANA
FA4626-12-D-0003
SMA PROJECT NO. 1707
TABLE OF CONTENTS
Enumeration of Drawings, Specifications and Addenda: The following are the Specifications and Drawings, and Addenda which form a part of this Contract:
See following Specifications for Bidding Requirements, Proposal, Special Conditions, etc.
SPECIFICATIONS
DIVISION 1
SECTION 01 00 00 – GENERAL REQUIREMENTS
SCHEDULE OF MATERIALS SUBMITTALS
QUALITY CONTROL REPORT TO INSPECTOR
SECTION 01 10 00 – SECURITY
SECURITY FORM (CEAL)
SECTION 01 36 00 – ENVIRONMENTAL PROTECTION
WASTE MANAGEMENT PLAN
RECOVERED MATERIALS WRITTEN DETERMINATION FORM
RECYCLED MATERIAL USE REPORT
MONTHLY REPORT OF SOLID WASTE DISPOSAL AND DIVERSION
SAMPLE OF HAZARDOUS MATERIAL LIST
SECTION 01 50 00 – TEMPORARY FACILITIES AND CONTROLS
DIVISION 2
SECTION 02 41 19 – SELECTIVE DEMOLITON
DIVISION 3 – NOT USED
DIVISION 4 – NOT USED
DIVISION 5
SECTION 05 12 00 – STRUCTURAL STEEL
DIVISION 6
SECTION 06 16 00 – SHEATING
SECTION 06 20 23 – INTERIOR FINISH CARPENTRY
SECTION 06 41 16 –LAMINATE FACED ARCHITECTURAL CABINETS
DIVISION 7
SECTION 07 24 13 –POLYMER-BASED EXTERIOR INSULATION & FINISH
SYSTEMS (EIFS)
SECTION 07 25 00 – WEATHER BARRIERS
SECTION 07 71 00 – ROOF SPECIALTIES
SECTION 07 92 00 – JOINT SEALANTS
DIVISION 8
SECTION 08 11 13 –STEEL DOOR AND FRAMES
SECTION 08 14 16 – FLUSH WOOD DOORS
SECTION 08 51 13 –ALUMINUM WINDOWS
SECTION 08 71 10 –DOOR HARDWARE
SECTION 08 80 00 – GLAZING
DIVISION 9
SECTION 09 29 00 – GYPSUM BOARD
SECTION 09 30 00 – TILING
SECTION 09 65 13 – RESILIENT BASE AND ACCESSORIES
SECTION 09 65 16 – RESILIENT SHEET FLOORING
SECTION 09 68 13 – TILE CARPETING
SECTION 09 72 00 – WALL COVERINGS
SECTION 09 77 20 – DECORATIVE FIBERGLASS REINFORCED PANELS
SECTION 09 91 13 – EXTERIOR PAINTING
SECTION 09 91 23 – INTERIOR PAINTING
SECTION 09 93 00 –STAINING AND TRANSPARENT FINISHING
DIVISION 10
SECTION 10 21 16 – PRECAST SHOWER BASINS AND WALLS PANELS
SECTION 10 28 00 – TOILET, BATH, AND LAUNDRY ACCESSORIES
DIVISION 11 – NOT USED
DIVISION 12
SECTION 12 36 61 – SIMULATED STONE COUTERTOPS
DIVISION 13 – NOT USED
DIVISION 14 – NOT USED
DIVISION 15 – NOT USED
DIVISION 16 – NOT USED
DIVISION 17 – NOT USED
DIVISION 18 – NOT USED
DIVISION 19 – NOT USED
DIVISION 20 – NOT USED
DIVISION 21 – NOT USED
DIVISION 22
SECTION 22 05 11 – COMMON WORK RESULTS FOR PLUMBING
SECTION 22 05 12 – GENERAL MOTOR REQUIREMENTS FOR PLUMBING
SECTION 22 05 23 – GENERAL DUTY VALVES FOR PLUMBING PIPING
SECTION 22 11 00 – FACILTY WATER DISTRIBUTION
SECTION 22 13 00 –FACILITY SANITARY SEWERAGE
SECTION 22 40 00 – PLUMBING FIXTURES
DIVISION 23
SECTION 23 05 11 – COMMON WORK RESULTS FOR HVAC AND STEAM GEN.
SECTION 23 05 12 – GENERAL MOTOR REQUIREMENTS FOR HVAC AND
NZAS 04-1042
STEAM GENERATION EQUIPMENT
SECTION 23 05 93 – TESTING ADJUSTING, AND BALANCING FOR HVAC
SECTION 23 07 11 – HVAC, PLUMBING, & BOILER PLANT INSULATION
SECTION 23 09 00 – CONTROL SYSTEMS FOR HVAC
SECTION 23 21 13 – HYDRONIC PIPING
SECTION 23 21 23 – HYDRONIC PUMPS
SECTION 23 31 00 – HVAC DUCTS AND CASING
SECTION 23 34 00 – HVAC FANS
SECTION 23 37 00 – AIR OUTLETS AND INLETS
SECTION 23 64 23 – AIR COOLED CHILLER
SECTION 23 82 00 – HEATING AND COOLING UNITS
DIVISION 24 – NOT USED
DIVISION 25 – NOT USED
DIVISION 26
SECTION 26 05 00 – GENERAL PROVISIONS FOR ELECTRICAL
SECTION 26 05 01 – ELECTRICAL DEMOLITION
SECTION 26 05 03 – EQUIPMENT WIRING CONNECTIONS
SECTION 26 05 19 – LOW VOLTAGE CONDUCTORS AND CABLES
SECTION 26 05 26 – GROUNDING AND BONDING
SECTION 26 05 29 – HANGERS AND SUPPORTS
SECTION 26 05 32 – CONDUIT
SECTION 26 05 33 – BOXES
SECTION 26 05 53 – IDENTIFICATION
SECTION 26 09 23 – LIGHTING CONTROL DEVICES
SECTION 26 27 26 – WIRING DEVICES
SECTION 26 28 19 – ENCLOSED SWITCHES
SECTION 26 43 00 – GUTTER DE-ICING SYSTEMS
SECTION 26 51 00 – INTERIOR LUMINAIRES
SECTION 26 52 00 – EMERGENCY LIGHTING
SECTION 26 56 00 -- EXTERIOR LIGHTING
DIVISION 27 – NOT USED
DIVISION 28
SECTION 28 31 74 – INTERIOR ADDRESSABLE FIRE ALARM
SECTION 28 31 76 – INTERIOR MASS NOTIFICATION
APPENDIX – PRODUCT DATA INFORMATION
DIVISION 29 – NOT USED
DIVISION 30 – NOT USED
DIVISION 31– NOT USED
DIVISION 32
SECTION 32 13 13 – CONCRETE PAVING
DIVISON 33 – NOT USED
DRAWINGS
COV COVER SHEET
PROJECT INFORMATION
SHEET INDEX
VICINITY MAP
LEGEND AND ABBREVIATIONS
GENERAL NOTES
ARCHITECTURAL
A0.00 ARCHITECTURAL SITE PLAN
A1.00 FIRST FLOOR EXISTING/DEMOLITION PLAN
A1.01 SECOND FLOOR EXISTING/DEMOLITION PLAN
A1.02 THIRD FLOOR EXISTING/DEMOLITION PLAN
A2.00 FIRST FLOOR RENOVATION PLAN
A2.01 SECOND FLOOR RENOVATION PLAN
A2.02 THIRD FLOOR RENOVATION PLAN
A2.03 FIRST FLOOR FINISH PLAN
A2.04 SECOND FLOOR FINISH PLAN
A2.05 THIRD FLOOR FINISH PLAN
A2.06 FIRST FLOOR REFLECTED CEILING PLAN
A2.07 SECOND FLOOR REFLECTED CEILING PLAN
A2.08 THIRD FLOOR REFLECTED CEILING PLAN
A3.00 DEMOLITION EXTERIOR ELEVATIONS
A3.01 DEMOLITION EXTERIOR ELEVATIONS
A3.02 RENOVATION EXTERIOR ELEVATIONS
A3.03 RENOVATION EXTERIOR ELEVATIONS
A4.00 INTERIOR ELEVATIONS & DETAILS
STRUCTURAL
S1.0 GENERAL STRUCTURAL NOTES
S2.0 TYPICAL DETAILS
MECHANICAL
M1.1 1st FLOOR PLUMBING & HV&AC DEMOLITION PLAN M1.2 2nd FLOOR PLUMBING & HV&AC DEMOLITION PLAN M1.3 3rd FLOOR PLUMBING & HV&AC DEMOLITION PLAN
M1.4 CORE HEATING WATER RISER DIAGRAMS
M1.5 WING-A HEATING WATER RISER DIAGRAMS
M1.6 WING-B HEATING WATER RISER DIAGRAMS
M2.1 1st FLOOR PLUMBING REVISIONS PLAN M2.2 2nd FLOOR PLUMBING REVISIONS PLAN M2.3 3rd FLOOR PLUMBING REVISIONS PLAN M3.1 1st FLOOR HV&AC REVISIONS PLAN M3.2 2nd FLOOR HV&AC REVISIONS PLAN M3.3 3rd FLOOR HV&AC REVISIONS PLAN
M4.1 DETAILS
M4.2 SCHEDULES & DETAILS
FIRE ALARM/MASS NOTIFICATION
FA0.00 NOTES AND LEGENDS
FA1.00 FIRST FLOOR DEMO PLAN
FA1.01 SECOND FLOOR DEMO PLAN
FA1.02 THIRD FLOOR DEMO PLAN
FA2.00 FIRST FLOOR NEW WORK PLAN
FA2.01 SECOND FLOOR NEW WORK PLAN
FA2.02 THIRD FLOOR NEW WORK PLAN
FA3.00 FIRST FLOOR NEW WORK PLAN
FA3.01 SECOND FLOOR NEW WORK PLAN
FA3.02 THIRD FLOOR NEW WORK PLAN
FA4.00 ELEVATION DETAILS
FA4.01 PANEL WIRING DETAILS
FA4.02 PANEL WIRING DETAILS
FA4.03 DEVICE WIRING DETAILS
FA5.00 NOTIFICATION RISER DIAGRAM
FA5.01 SLC RISER DIAGRAM
FA6.00 I/O MATRIX
FA7.00 NAC LOAD/LOSS CALCULATIONS
FA7.01 BATTERY CALCULATIONS
ELECTRICAL
E1.1 ELECTRICAL SITE PLAN
E2.1 1St FLOOR ELECTRICAL DEMO E2.2 2nd FLOOR ELECTRICAL DEMO E2.3 3rd FLOOR ELECTRICAL DEMO E3.1 1St FLOOR LIGHTING REMODEL E3.2 2nd FLOOR LIGHTING REMODEL E3.3 3rd FLOOR LIGHTING REMODEL E3.4 1St FLOOR POWER REMODEL E3.5 2nd FLOOR POWER REMODEL E3.6 3rd FLOOR POWER REMODEL
END OF TABLE OF CONTENTS