This is a Demolition Asbestos Survey Report prepared by GLE Associates, Inc. for Clay County Fire Rescue Station 24 located at 5105 Sweat Road in Green Cove Springs, Florida. The survey was conducted on February 18, 2026, by EPA/AHERA accredited inspector Zac Klarich to identify asbestos-containing materials (ACMs) in preparation for the facility's demolition. A total of twenty-one samples representing seven homogeneous material areas were collected and analyzed using Polarized Light Microscopy (PLM) coupled with dispersion staining. The survey encompassed both the Fire Station and Well House structures, evaluating accessible areas including cement slabs, vinyl floor tile, ceiling tiles, concrete masonry units, roofing shingles, and carpet adhesive. The report does not include demolition of building components, architectural evaluation, material quantification for abatement purposes, or removal cost estimates.
The survey identified asbestos-containing materials in one location: 12" x 12" pink vinyl floor tile with 7 percent chrysotile asbestos located in the laundry and storage room floors, classified as Category I non-friable ACM and designated as Regulated ACM (RACM) due to the high probability of becoming friable during demolition operations. All other tested materials, including cement slabs, ceiling tiles, concrete masonry units, roofing shingles, and adhesives, tested negative for asbestos content. The report recommends that the identified RACM be maintained under an Operations and Maintenance Program with periodic monitoring prior to demolition, and that a licensed asbestos abatement contractor properly remove and dispose of the material before conducting any demolition activities. The survey notes that hidden materials may exist within building cavities or beneath existing surfaces and should be assumed to be asbestos-containing until proven otherwise through sampling and analysis.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8651 Baypine Road, Suite 115 Jacksonville, Florida 32256
904-296-1880 • Fax 904-296-1860
DEMOLITION ASBESTOS SURVEY REPORT
Clay County Fire Rescue Station 24 5105 Sweat Road
Green Cove Springs, Florida
GLE Project No.: 26000-32638
Prepared for:
Mr. Chad Josi Clay County
1565 County Road 315 Green Cove Springs, Florida 32043
February 2026
Prepared by:
GLE Associates, Inc.
8651 Baypine Road, Suite 115 | Jacksonville, Florida 32256 | 904-296-1880 | Fax: 904-296-1860
Tampa | Orlando | Ft. Lauderdale | Miami | Gainesville | Atlanta | Nashville Architecture AR 0007729 Engineer RY 5483 Asbestos ZA 0000034 Geology PG 1737
February 26, 2026
Mr. Chad Josi Clay County 1565 County Road 315 Green Cove Springs, Florida 32043
RE: Demolition Asbestos Survey Report
Clay County Fire Rescue Station 24 – Fire House and Well House 5105 Sweat Road Green Cove Springs, Florida
GLE Project No.: 26000-32638
Dear Mr. Josi:
GLE Associates, Inc. (GLE) performed a Demolition survey for asbestos-containing materials (ACM) on February 18, 2026, at Clay County Fire Rescue Station 24, located in Green Cove Springs, Florida. The survey was performed by Mr. Zac Klarich with GLE. This report outlines the sampling and testing procedures, and presents the results along with our conclusions and recommendations.
GLE appreciates the opportunity to serve as your consultant on this project. If you should have any questions, or if we can be of further service, please do not hesitate to call.
Sincerely, GLE Associates, Inc.
Zac Klarich Robert B. Greene, PE, PG, CIH, LEED AP Project Manager President
Florida LAC# EA 0000009
ZK/PSZ/RBG/lr
M:\Work\Asb\2026\26000\32638.Clay County.Pre-Demo ACM Fire Rescue 24\Report\SurveyReport COJ.doc
TABLE OF CONTENTS
1.0 INTRODUCTION 1
1.1 Introduction 1
1.2 Facility Description 1
2.0 RESULTS 1
2.1 Asbestos Survey Procedures 1
2.2 Identified Suspect Asbestos-Containing Materials 2
Table 2.2-1 — Summary of Homogeneous Sampling Areas
3.0 CONCLUSIONS AND RECOMMENDATIONS 4
3.1 General 4
3.2 Specific 5
4.0 LIMITATIONS AND CONDITIONS 5
APPENDICES
Appendix A – Analytical Results and Chain of Custody Appendix B – Personnel and Laboratory Certifications
1.0 INTRODUCTION
1.1 INTRODUCTION
The purpose of this Demolition survey was to identify accessible asbestos-containing materials (ACMs) and their general locations within Clay County Fire Rescue Station 24, located at 5105 Sweat Road in Green Cove Springs, Florida. The survey was conducted pursuant to National Emission Standards for Hazardous Air Pollutants (NESHAP, 40 CFR 61) requirements, associated with the scheduled Demolition plans. The survey was performed on February 18, 2026, by Mr. Zac Klarich, an Environmental Protection Agency/Asbestos Hazard Emergency Response Act (EPA/AHERA) accredited inspector. The scope of this survey did not include demolition of any building components, evaluation of architectural plans, or the quantification of materials for abatement purposes, or removal cost estimating.
1.2 FACILITY DESCRIPTION
A summary of the facility investigated is outlined in the table below.
Facility Type: Fire Station Construction Date: Unknown Number of Floors: 1
Exterior Floor Support: Concrete Slab on Grade Wall Support: Metal Framing Exterior Finish: Paint Roof System Type: Metal Panel
Mechanical/Plumbing HVAC Type: Ground Package HVAC System Duct Type Not Observed Pipe Insulation: Not Observed
Interior Wall Substrate: Metal Panels, Wood Panels Wall Finishes: Paint, Texture Floor Finishes: Vinyl Floor Tile Ceiling System: Suspended Ceiling System Ceiling Finishes: Suspended Ceiling Tiles
2.0 RESULTS
2.1 ASBESTOS SURVEY PROCEDURES
The survey was performed by visually observing accessible areas within the scope of work. An EPA/AHERA accredited inspector performed the visual observations (refer to Appendix B for personnel qualifications).
After the overall visual survey was completed, representative sampling areas were determined.
The surveyor delineated homogeneous areas of suspect materials and samples of each material were obtained, in general accordance with regulations as established by the Occupational Safety and Health Administration (OSHA) and NESHAP. The field surveyor determined sample locations based on previous experience. Both friable and non-friable materials were sampled. A friable material is one that can be crushed when dry by normal hand pressure. This survey did not include the demolition of building components to access suspect material.
After completion of the fieldwork, the samples were delivered to GLE’s National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory for analysis. The samples were analyzed by Polarized Light Microscopy (PLM) coupled with dispersion staining, in general accordance with EPA-600/R-93/116. Utilizing this procedure, the various asbestos minerals (chrysotile, amosite, crocidolite, actinolite, tremolite, and anthophyllite) can be determined. The percentages of asbestos minerals in the samples were visually determined by the microscopist. Please note that the EPA designates all materials containing greater than one percent asbestos as an “asbestos-containing material” (ACM).
Regulated Asbestos-Containing Material (RACM) is defined as (a) Friable asbestos materials,
(b) Category I non-friable ACM that has become friable, (c) Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (d) Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by this subpart.
Category I and Category II non-friable ACM, as defined by the EPA:
Category I non-friable ACM means asbestos-containing packings, gaskets, resilient floor covering, asphalt roofing products, and pliable sealants and mastics that are in good condition and not friable, containing more than one percent asbestos, as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM.
Category II non-friable ACM means any material, excluding Category I non-friable ACM, containing more than 1 percent asbestos as determined using the methods specified in Appendix E, Subpart E, 40 CFR Part 763 Section 1, PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
2.2 IDENTIFIED SUSPECT ASBESTOS-CONTAINING MATERIALS
A total of twenty-one samples of suspect building materials were collected from the facility during the survey, representing seven different identified homogeneous areas. The results of the laboratory analyses are included in Appendix A.
ASBESTOS CONTENT
Expressed as percent
* = The facility owner has the option of point-counting by Polarized Light Microscopy (PLM) those RACM whose asbestos content is less than 10% in order to more accurately determine the asbestos content therein.
FRIABILITY F = Friable Material NF = Non-Friable Material
ACM CATEGORY RACM = Regulated ACM CAT I = Category I non-friable ACM CAT II = Category II non-friable ACM
ABBREVIATIONS:
PC = Results based on Point-Count analysis TEM NOB = Transmission Electron Microscopy of Non-Friable Organically Bound Material
NA = Not Applicable ND = None Detected NIS = Not in Scope C = Chrysotile A = Amosite
HA = Homogeneous Area SF = Square Feet LF = Linear Feet CF = Cubic Feet
TABLE 2.2-1: SUMMARY OF HOMOGENEOUS SAMPLING AREAS
CLAY COUNTY FIRE RESCUE STATION 24 – GREEN COVE SPRINGS, FLORIDA
HA # HOMOGENEOUS MATERIAL
DESCRIPTION
HOMOGENEOUS MATERIAL
LOCATION
FRIABILITY
(F/NF)
% ASBESTOS* # OF SAMPLES
COLLECTED
APPROXIMATE
QUANTITY
ACM
CATEGORY
M-01 Cement Slab Slab Throughout NF ND 3 NIS NA
FT-01
12" x 12" Pink Vinyl Floor Tile with Yellow Adhesive Laundry Room and Storage
Room Floor
NF
Floor Tile - 7% C Yellow Adhesive - ND
3 150 SF CAT I
CT-01 2' x 4' Ceiling Tile Laundry Room and Storage Room
Ceiling
F ND 3 NIS NA
M-02 CMU Wellhouse Walls NF ND 3 NIS NA
M-03 Cement Slab - Wellhouse Wellhouse Slab NF ND 3 NIS NA
RS-01 Black Roofing Shingles - Wellhouse Wellhouse Roofing NF ND 3 NIS NA
MAS-01 Yellow Carpet Adhesive Fire Station Gym Floor NF ND 3 NIS NA
Notes/Observations:
No suspect duct mastic was observed within the scope of the survey No suspect pipe insulation was observed within the scope of the survey
3.0 CONCLUSIONS AND RECOMMENDATIONS
3.1 GENERAL
Asbestos-containing materials (ACMs) were identified in the scope of this survey. General and specific conclusions and recommendations are provided below.
The EPA, OSHA and the State of Florida have promulgated regulations dealing with asbestos.
For commercial building owners, the EPA NESHAP (40 CFR 61) regulations require removal of RACM, prior to conducting activities which might disturb the material. They also deal with notification, handling and disposal of asbestos.
The EPA recommends that an Operations and Maintenance (O&M) Program be developed for any facilities with ACM, and this Program should address all ACM (known and/or assumed) present. The O&M Program establishes notification and training requirements along with special procedures for working around the ACM. The O&M Program would remain in effect until all asbestos is removed.
Category I and Category II non-friable materials, as defined by the EPA, may remain within a facility during demolition with no potential cessation of work, provided they remain non-friable and the appropriate engineering controls (i.e., wet methods) are utilized, with the resulting waste disposed of as asbestos-containing waste. However, there is no guarantee that these materials will remain non-friable. If the materials become friable, then they are classified as RACM.
Additionally, local jurisdictions may have more stringent interpretations regarding classification of these materials.
RACM, as defined by the EPA, must be removed prior to renovation or demolition activities that may disturb the materials.
The OSHA regulations deal with employee exposure to airborne asbestos fibers. The regulations restrict employee exposure, and require special monitoring, training and handling procedures when dealing with asbestos. Additionally, OSHA has regulations that may supersede the EPA regulations. In order to protect the worker, OSHA has established a permissible exposure limit (PEL), which limits employee exposure to airborne fiber concentrations. OSHA requires objective evidence that the PEL will not be exceeded, as justification that personal air monitoring and engineering controls will not be required. OSHA has also established rules requiring the containerization and labeling of asbestos waste.
The State regulations require that anyone involved in asbestos consulting activities be a licensed asbestos consultant and that anyone involved in asbestos abatement, with the exception of roofing materials, be a licensed asbestos abatement contractor.
3.2 SPECIFIC
FT-01 12" x 12" Pink Vinyl Floor Tile:
This material is defined by the EPA as a Category I non-friable material. This material has a high probability of becoming friable by the forces expected to act on the material in the course of demolition operations. Therefore, it will be classified as RACM. The identified RACM does not appear to present a significant issue, as observed, at the time of the survey. We recommend that the identified RACM be maintained as part of an O&M Program and periodically monitored for any changes in condition prior to demolition. Additionally, we recommend that a licensed asbestos abatement contractor properly remove and dispose of the RACM prior to conducting demolition activities that might disturb the ACM.
4.0 LIMITATIONS AND CONDITIONS
As a result of previous renovations, there may be hidden materials, such as floor tile, sheet vinyl flooring, insulation, etc. These materials may be found in various areas hidden under existing flooring materials or in wall cavities. Any materials found during construction activities, either not addressed in this survey report, or similar to the ACM identified in this survey report should be assumed to be ACM until sampling and analysis documents otherwise.
Because of the hidden nature of many building components (i.e. within mechanical chases), it may be impossible to determine if all of the suspect building materials have been located and subsequently tested. Destructive testing in some instances is not a viable option. We cannot, therefore, guarantee that all potential ACM has been located. For the same reasons, estimates of quantities and/or conditions are subject to readily apparent situations, and our findings reflect this condition. We do warrant, however, that the investigations and methodology reflect our best efforts based upon the prevailing standard of care in the environmental industry.
The information contained in this report was prepared based upon specific parameters and regulations in force at the time of this report. The information herein is only for the specific use of the client and GLE. GLE accepts no responsibility for the use, interpretation, or reliance by other parties on the information contained herein, unless prior written authorization has been obtained from GLE.
APPENDIX A
Analytical Results and Chain of Custody
SUMMARY OF BULK SAMPLE ANALYSIS
Clay County Board of County Commissioners(BOCC); Fire Apparatus Building-Fire
Station 24 & Wellhouse 26000-32638
Sample Sample Type Fiber Type
M-01A Cement Slab 100% Quartz, Calcite, Clay, Mica
M-01B Cement Slab 100% Quartz, Calcite, Clay, Mica
M-01C-QC Cement Slab 100% Quartz, Calcite, Clay, Mica
FT-01A 12" x 12" Pink Vinyl
Floor Tile
7% Chrysotile Asbestos
93% Polymer, Quartz, Calcite, Clay, Mica
Yellow Mastic 100% Polymer
FT-01B 12" x 12" Pink Vinyl
Floor Tile Positive Stop/Sample not analyzed
Yellow Mastic 100% Polymer
FT-01C 12" x 12" Pink Vinyl
Floor Tile Positive Stop/Sample not analyzed
Yellow Mastic 100% Polymer
CT-01A 2' x 4' Ceiling Tile 100% Mineral Wool
CT-01B 2' x 4' Ceiling Tile 100% Mineral Wool
CT-01C 2' x 4' Ceiling Tile 100% Mineral Wool
M-02A Concrete Masonry Unit 100% Quartz, Calcite, Clay, Mica
M-02B Concrete Masonry Unit 100% Quartz, Calcite, Clay, Mica
M-02C Concrete Masonry Unit 100% Quartz, Calcite, Clay, Mica
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020 as found in App. E to Sub.
E of 40 CFR Part 763, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 30987
Analyst / Approved
Signatory:
Feedback regarding laboratory performance should be addressed to lab@gleassociates.com.
Report Date: 2/20/2026
SUMMARY OF BULK SAMPLE ANALYSIS
Clay County Board of County Commissioners(BOCC); Fire Apparatus Building-Fire
Station 24 & Wellhouse 26000-32638
Sample Sample Type Fiber Type
M-03A-QC Wellhouse Slab 100% Quartz, Calcite, Clay, Mica
M-03B Wellhouse Slab 100% Quartz, Calcite, Clay, Mica
M-03C Wellhouse Slab 100% Quartz, Calcite, Clay, Mica
RS-01A Black Roofing Shingles 100% Bitumen, Quartz, Calcite, Mica
RS-01B Black Roofing Shingles 100% Bitumen, Quartz, Calcite, Mica
RS-01C Black Roofing Shingles 100% Bitumen, Quartz, Calcite, Mica
MAS-01A Yellow Carpet Adhesive 100% Polymer
MAS-01B Yellow Carpet Adhesive 100% Polymer
MAS-01C Yellow Carpet Adhesive 100% Polymer
Darryl Neldner
* Polarized Light Microscopy coupled with dispersion is the technique used for identification in accordance with EPA 600/M4-82-020 as found in App. E to Sub.
E of 40 CFR Part 763, EPA 600/R-93/116, and NIOSH Method 9002.
** The percentage of each component is visually estimated. The result of this analysis relate only to the material tested.
The report shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.
(>1% greater than one percent, <1% less than one percent) QC - Sample reanalyzed for QA/QC.
Analysis performed by GLE Associates, Inc. NVLAP Code 102003-0, CO AL-17485, TX 30-0337
*** This report shall not be reproduced except in full, without the written approval of the laboratory. GLE Report # 30987
Analyst / Approved
Signatory:
Feedback regarding laboratory performance should be addressed to lab@gleassociates.com.
Report Date: 2/20/2026
APPENDIX B
Personnel and Laboratory Certifications
Melanie S. Griffin, SecretaryRon DeSantis, Governor
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
ASBESTOS LICENSING UNIT
THE ASBESTOS BUSINESS ORGANIZATION HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 469, FLORIDA STATUTES
GLE ASSOCIATES INC
Do not alter this document in any form.
ROBERT BLAIR GREENE
LICENSE NUMBER: ZA0000034
EXPIRATION DATE: NOVEMBER 30, 2027
This is your license. It is unlawful for anyone other than the licensee to use this document.
5405 CYPRESS CENTER DRIVE
SUITE 110
TAMPA FL 33609
Always verify licenses online at MyFloridaLicense.com
ISSUED: 10/02/2025
https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=2c9db36082555fee1afe88b159c9ca06 https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=2c9db36082555fee1afe88b159c9ca06
Melanie S. Griffin, SecretaryRon DeSantis, Governor
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
ASBESTOS LICENSING UNIT
THE ASBESTOS CONSULTANT - ENGINEER HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 469, FLORIDA STATUTES
GREENE, ROBERT BLAIR
Do not alter this document in any form.
GLE ASSOCIATES INC
LICENSE NUMBER: EA0000009
EXPIRATION DATE: NOVEMBER 30, 2026
This is your license. It is unlawful for anyone other than the licensee to use this document.
5405 CYPRESS CENTER DR
SUITE 110
TAMPA FL 33609
Always verify licenses online at MyFloridaLicense.com
ISSUED: 09/24/2024
https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=10324f95ba50b55978623c96241000ac https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=10324f95ba50b55978623c96241000ac
GLE Associates, Inc. FL 49-0001218 5405 Cypress Center Drive, Suite 110, Tampa, Florida 33609 • (813) 241-8350 certifies that
Zachary Klarich has completed the requisite training for
ASBESTOS INSPECTOR REFRESHER
accreditation under TSCA Title II Course No.: FL 49-0002824 conducted on
April 3, 2025 At
TAMPA, FLORIDA
Certificate Number
Passed Exam on April 3, 2025 with score of 70% or better.
Last 4 SSN: 6593
EPA Accreditation Expires: April 3, 2026 Instructor Catherin Meilak
GLE Associates, Inc. Robert B. Greene
Instructorrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr
File details come from the government source that posted it. Updated .