Addendum_#1_-_Clay_Co_FS_24_-_Civil_(2026_02-17)_.pdf
PDF 4 MB Posted
- Attached to
- Construction of Clay County Fire Station No. 24
- Solicitation number
- 25/26-042
- Issued by
- Clay County, Harold CDP, Florida
About this file
This is Addendum #1 to the bid documents for the construction of Clay County Fire Station No. 24, issued by the Clay County Board of County Commissioners for a new approximately 16,633-square-foot, four-bay fire station facility located at 1075 County Road 226 in Green Cove Springs, Florida. The project encompasses complete construction including demolition of existing structures, site preparation, grading, drainage installation, pavement, utility infrastructure (potable water wells, fire protection systems, and septic wastewater management), and all associated trades including structural steel, carpentry, plumbing, HVAC systems, electrical systems with 1,000-ampere service and diesel generator backup, fire suppression and alarm systems, communications infrastructure, and landscape installation with irrigation. The construction is organized in two phases: Phase 1 covers site preparation, demolition, grading, drainage, pavement, and utilities installation, while Phase 2 includes stormwater management expansion and final site grading. The mandatory pre-bid meeting was scheduled for February 6, 2026, at 10:00 a.m. at the project site, with inquiries due by February 13, 2026, at 4:30 p.m. through the Question and Answer tab. Sealed bids were due electronically through the County's e-Procurement Portal by March 2, 2026, at 4:00 p.m., with bid opening on March 3, 2026, at 9:00 a.m. The project requires substantial completion by March 15, 2027, and final Certificate of Occupancy by March 20, 2027, to meet grant deadline requirements, with liquidated damages of $1,000 per day assessed for delays beyond the final completion date.
All bidders must be Florida-licensed General Contractors registered with the Florida Construction Industry Licensing Board in good standing with the State of Florida Department of State, Division of Corporations, and must have been in business for a minimum of five years performing similar work. Evaluation criteria include a five percent bid bond requirement, 100 percent Performance and Payment Bond per Florida Statute 255.05, and comprehensive insurance requirements including Commercial General Liability of $1,000,000 per occurrence and $2,000,000 aggregate, Workers' Compensation at statutory limits, and Builder's Risk coverage equal to 100 percent of project value with a maximum $25,000 deductible. The project is funded in whole or in part by Federal Emergency Management Agency (FEMA) Public Assistance Grant Program funding and therefore requires compliance with federal regulations including 2 CFR Part 200 (Uniform Guidance), the FEMA Field Manual for Public Assistance, and Davis-Bacon Act prevailing wage requirements. The site contains protected species including Eastern Indigo Snakes and Tri-Colored Bats, requiring implementation of specific protective measures in coordination with qualified environmental professionals and compliance with Florida Fish and Wildlife Conservation Commission and U.S. Fish and Wildlife Service guidelines, with violations carrying civil penalties up to $25,000 and criminal penalties up to $50,000 and/or imprisonment. The County reserves the right to approve all subcontractors and may utilize a Direct Purchase Program to procure major materials directly, with County purchases deducted from the contract price. A two-year warranty period applies to all improvements. No specific budget or award value is stated in the available solicitation documents.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ENGINEER:
GOODSON, BERGEN AND ASSOCIATES
Consulting Engineers
APPLICANT/
DEVELOPER:
VICINITY MAP
C0.01-800-432-4770
BEFORE YOU DIG !
CALL SUNSHINE STATE ONE CALL OF FLORIDA
AT LEAST TWO FULL BUSINESS DAYS BEFORE
DIGGING OR DISTURBING EARTH
Know what's below.
before you dig.Call
R
GENERAL PROJECT INFORMATION
GBA ENGINEERING BUSINESS 32987
JUNE 23, 2023
FL REG # 63060
GBA PROJECT NUMBER - 190161
CL
AY
CO
UN
TY
F
IRE
ST
AT
IO
N 2
C O
U N
T Y
R O
A D
G R
E E
N C
O V
E S
P R
IN
G
S , F
L
CLAY COUNTY FIRE RESCUE
FOR
LANDSCAPE
ARCHITECT:
MEG GAFFNEY-COOKE RLA, LEED AP
BLUE LEAF LANDSCAPE
904-517-1225 www.blueleaflandscape.com
SHEET NO. TITLE
TOPOGRAPHIC SURVEY
COVER SHEET
INDEX OF DRAWINGS
GENERAL NOTES
GEOMETRY AND PAVING PLAN PHASE 1
GRADING AND DRAINAGE PLAN PHASE 2
LANDSCAPE PLAN
EROSION AND SEDIMENT CONTROL DETAILS
C1.0
NPDES DETAIL SHEET #1
NPDES DETAIL SHEET #2
LANDSCAPE SPECIFICATIONS
LANDSCAPE DETAILS
C2.0
C4.0 C5.0 C6.0
C15.0
C7.0
C13.0 C14.0
L1.1
L2.1 L2.2
C3.0
CONSTRUCTION DETAILS
C8.0
CONSTRUCTION DETAILS
C9.0
C16.0
STORM WATER POLLUTION PREVENTION PLAN
GENERAL NOTES
C10.0 C11.0 C12.0
C17.0
PRE DEVELOPMENT DRAINAGE PLAN
POST DEVELOPMENT DRAINAGE PLAN
MAINTENANCE OF TRAFFIC PLAN
C0.0
DEMOLITION PLAN PHASE 1
5105 SWEAT RD
GREEN COVE SPRINGS,
FL 32043
GENERAL
Parcel ID # __________________
Zoning Designation __________________ PUD Ordinance Number __________________ FIRM – Community – Panel __________________ Flood Zones (Show in Plans) __________________ Base Flood Elev. (Show in Plans) __________________ Vertical Datum Used for Project __________________ UtilityAvailability Number __________________
NON-SUBDIVISION
New Impervious Area (bldg) __________________ Total Impervious Area __________________
NA
PO-1
12019C0295E
ZONE X
N.A.V.D.-1988
NA
16,837 SF
015781-001-00
NA
CLAY COUNTY BD OF
COUNTY COMM
ARCHITECT
DASHER HURST ARCHITECTS
1022 PARK STREET, SUITE 208
JACKSONVILLE, FLORIDA 32204
PHONE: 904.425.1190
WWW.DASHERHURST.COM
CONSTRUCTION DETAILS
GO
OD
SO
N B
ER
GE
N &
AS
SO
CIA
TE
S
C
E N
T R
A L
P A
R K
W A
Y
S U
IT
E
JA
C
K S
O N
V
IL
LE
, F
LO
R
ID
A
EDWARD GOODSON/ JEFFREY E. BERGEN, P.E.
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FLORIDA 32224
(OFFICE) (904) 519-7770
(FAX) (904) 519-7776
FL. PE #63060
JEFFREY E. BERGEN, PE
THIS ITEM HAS BEEN ELECTRONICALLY
SIGNED AND SEALED BY
JEFFREY E. BERGEN, PE ON
USING A SHA AUTHENTICATION CODE.
PRINTED COPIES OF THIS DOCUMENT
ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SHA
AUTHENTICATION CODE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
77,987 SF
SITE
LOCATION
DEMOLITION NOTES & LEGEND
CLAY COUNTY UTILITY AUTHORITY STANDARD SHEETS
WAT 02
WAT 03
STANDARD WATER CASING, CROSSING TYPE AND PIPE
RESTRAINT DETAILS
STANDARD WATER CASING. CROSSING TYPE AND PIPE
RESTRAINT DETAILS
C19.0 C18.0
C20.0 C21.0
UTILITY PLAN
GRADING AND DRAINAGE PLAN PHASE 1
DEMOLITION PLAN PHASE 2
GEOMETRY AND PAVING PLAN PHASE 2
C22.0
SEPTIC SYSTEM
LANDSCAPE INDEXL1.0
LANDSCAPE PLANL1.2
C23.0
WELL SYSTEMS 2 (SHEET REMOVED)
IRRIGATION PLANI1.1
IRRIGATION DETAILSI2.1
IRRIGATION SPECIFICATIONSI2.2
CONCRETE JOINT PLANC9.0A
VE Rev 13 07-19-2024
REVISIONS
# DATE DESCRIPTION
90% IRC REVIEW4 09-05-2025
S-SPA STANDARD WATER AND SEWER SYSTEM SPECIFICATIONS
C15.1 FENCE DETAILS
WAT 04 STANDARD FIRE HYDRANT AND D.D.C.V BACKFLOW
PREVENTER DETAILS
S-SEW STANDARD SEWER SYSTEM DETAILS
PERMIT SET
90% IRCV.2 REVS5 01-05-2026
ADD # 16 02-17-2026
WELL SYSTEMS 1 (SHEET REMOVED)
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M
22003
6/23/2023
C O
UN
TY
R O
A D
G
RE
EN
C
O V
E
SP
RI
N
G S, F L
BID DOCUMENTS
C
LA
Y C
O
UN
TY
C
LA
Y C
O F
IR
E
ST
A
TI
O
N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
REVISIONS
# DATE DESCRIPTION
JEFFREY E. BERGEN, PE
THIS ITEM HAS BEEN ELECTRONICALLY
SIGNED AND SEALED BY
JEFFREY E. BERGEN, PE ON
USING A SHA AUTHENTICATION CODE.
PRINTED COPIES OF THIS DOCUMENT
ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SHA
AUTHENTICATION CODE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
PERMIT SET
DEMOLITION
PLAN
PHASE 2
C7.0
SCALE IN FEET
20 10 20
1-800-432-4770
BEFORE YOU DIG !
CALL SUNSHINE STATE ONE CALL OF FLORIDA
AT LEAST TWO FULL BUSINESS DAYS BEFORE
DIGGING OR DISTURBING EARTH
Know what's below.
before you dig.Call
R
SF
LEGEND
SILT FENCE
NOTES:
1. CONFIRM ALL TREES IMPACT WITH LANDSCAPE PLANS PRIOR TO
DEMOLITION.
2. SEE ADDITIONAL DEMOLITION NOTES AND LEGEND ON SHEET C3.0.
3. EXISTING WELL SHALL NOT BE USED ONCE NEW SEPTIC SYSTEM
BECOMES OPERATIONAL.
TB SILT FENCE / TURBIDITY BARRIER
INLET SEDIMENT PROTECTION
GENERAL PAVEMENT, BUILDING, CURBING
AND VERTICAL/SURFACE IMPROVEMENT
DEMOLITION, SOIL DISTURBANCE
GENERAL PAVEMENT, BUILDING, CURBING
AND VERTICAL/SURFACE IMPROVEMENT
DEMOLITION, SOIL DISTURBANCE (SEE
SPECIAL DEMOLITION NOTE ON PLAN)
NOTE:
ALL SITE CLEARING AND GRUBBING ACTIVITIES
HAVE BEEN COMPLETED. ALL EXISTING
IMPROVEMENTS SHOWN TO BE REMOVED ARE STILL
REQUIRED TO BE REMOVED.
TREE PROTECTION BARRICADE
XXXX
X X
X X
X X
X X
X X X X X X X
X X
X X
X X
X X
X
XX
W
SF
W
W
W W
W W
W W
W
W W
PROPOSED
FIRE STATION
4 BAYS / 16,633 S.F.
(REFER TO ARCHITECTURAL PLANS FOR
EXACT BUILDING DIMENSIONS)
F.F.E. =65.50
D O
N O
T EN
TER
D O
N O
T EN
TER
0 4 9 5
57 58 59
8 5 0 5 1 5
SWMF-1
R A
M P
D O
W N
RAMP
DOWN
RAMP
DOWN
EXISTING LIVING
QUARTERS
SWEAT ROAD
CO
UNTY RO
AD No. 226
.0
.051
.0
.0 52
.0
50.0
52.0
54.0
.0
RAMP
DOWN
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SFSFSF
SFSFSFSFSFSFSF
W
CHK VLVE
T B
PROPERTY LINE
SPECIAL DEMOLITION NOTE:
EXISTING GARAGE AND CONCRETE APRONS TO BE
DEMOLISHED SOONER THAN OTHER PHASE 2 ELEMENTS
TO ALLOW FOR THE CONSTRUCTION OF THE NEW SEPTIC
SYSTEM DRAIN FIELD. THIS SHALL BE COORDINATED WITH
THE CLAY COUNTY FIRE DEPARTMENT
INSTALL AND MAINTAIN SILT FENCE DURING
CONSTRUCTION PERIOD.
DO NOT REMOVE UNTIL ALL IS STABILIZED AND
GROUND COVER IS WELL ESTABLISHED.
8" THICK CRUSH-CRETE PAVEMENT
ADDED IN PHASE1 TO BE
DEMOLISHED
CONCRETE BLOCK
PUMPHOUSE / WELL TO BE
DEMOLISHED (SEE NOTE 3)
DRAIN FILL AND SEPTIC TANK TO BE
DEMOLISHED/ ABANDONED BY A LICENSED
CONTRACTOR SEPTIC / WELL
BUILDING TO BE
DEMOLISHED
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE PAVEMENT
SILT FENCE / TURBIDITY BARRIER DURING
PHASE 2 POND EXPANSION
TREE PROTECTION
SYNTHETIC HAY BALES
INLET SEDIMENT
PROTECTION
(TYP.)
PROVIDE INLET SEDIMENTATION CONTROLS AT NEW
INLETS DURING CONSTRUCTION UNTIL SURROUNDING
AREAS ARE STABILIZED (TYP.)
SF SF
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M
22003
6/23/2023
C O
UN
TY
R O
A D
G
RE
EN
C
O V
E
SP
RI
N
G S, F L
BID DOCUMENTS
C
LA
Y C
O
UN
TY
C
LA
Y C
O F
IR
E
ST
A
TI
O
N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
REVISIONS
# DATE DESCRIPTION
JEFFREY E. BERGEN, PE
THIS ITEM HAS BEEN ELECTRONICALLY
SIGNED AND SEALED BY
JEFFREY E. BERGEN, PE ON
USING A SHA AUTHENTICATION CODE.
PRINTED COPIES OF THIS DOCUMENT
ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SHA
AUTHENTICATION CODE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
PERMIT SET
SCALE IN FEET
20 10 20
1-800-432-4770
BEFORE YOU DIG !
CALL SUNSHINE STATE ONE CALL OF FLORIDA
AT LEAST TWO FULL BUSINESS DAYS BEFORE
DIGGING OR DISTURBING EARTH
Know what's below.
before you dig.Call
R
RAMP
DOWN
GEOMETRY AND
PAVING PLAN
PHASE 1
C8.0
# OF PARKING STALLS
TRUNCATED DOMES DETECTABLE
WARNING SURFACE (ADA COMPLIANT)
CURB TRANSITION
CT
BENCHMARK LOCATION
CURVE DATA
NO.
C1 72.00 66.60 35.9053° 0' 0"
C2 63.00 30.42 15.5127° 39' 44"
RADIUS DELTA TANGENT LENGTH
LEGEND
R1-1 (36"x36")
TAG SIGN
2 (12"x18")
(12"x4")
SIGN LEGEND
GEOMETRY NOTES:
1. ALL CURB RADII ARE 4.5' UNLESS NOTED
OTHERWISE.
2. ALL SIDEWALK RADII ARE 5' UNLESS NOTED
OTHERWISE.
3. REFER TO ARCHITECTURAL PLAN FOR EXACT
BUILDING DIMENSIONS
SIDEWALK RAMP (SLIP RESISTANT)
(ADA COMPLIANT)
R5-1 (30")
INDICATES SIGNS TO BE
MOUNTED BACK TO BACK
A
PARKING SUMMARY
STANDARD (9X18) (PUBLIC)......... =20
HC PARKING (12X18)..................... = 2
STANDARD (9X18) (SECURED).... = 16
TOTAL VEHICLE PARKING........... =38
BICYCLE PARKING......................... =2
HD
SD
CONCRETE SIDEWALK
5 (18"x12")
LOW EMITTING,
FUEL EFFICIENT
VEHICLE
PARKING ONLY
HEAVY DUTY (HD) CONCRETE
PAVEMENT
SUPER DUTY (SD) CONCRETE
PAVEMENT (ON SITE)
STANDARD DUTY (STD) ASPHALT
PAVEMENT
HEAVY DUTY (HD) ASPHALT
PAVEMENT
CRUSH-CRETE
7 " EMERGENCY VEHICLE
EXIT" (24") LOCATED
BELOW " DO NOT ENTER
SIGN"
ELECTRIC VEHICLE
6 (18"x12")
ELECTRIC
VEHICLE
PARKING ONLY
XXXX
X X
X X
X X
X X
X X X X X X X
X X
X X
X X
X X
X
XX
DRAIN FIELD
TOP EL=64.0
PROPOSED
FIRE STATION
4 BAYS / 16,633 S.F.
(REFER TO ARCHITECTURAL PLANS FOR
EXACT BUILDING DIMENSIONS)
F.F.E. =65.50
3' CT
D O
N O
T EN
TER
D O
N O
T EN
TER
SWMF-1
6' CT
6' CT
3' CT
R A
M P
D O
W N
RAMP
DOWN
RAMP
DOWN
SWEAT ROAD
CO
UNTY RO
AD No. 226
SD
SD
3' CT
3' CT
3' CT
3'
CT
3' CT
3' CT
6' CT
RAMP
DOWN
HD
3' CT
3' CT
HD
HD
3' CT
CHK VLVE
PROPERTY LINE
3 A
A 7 1
1 1
DUMPSTER ENCLOSURE
SEE ARCHITECTURAL
DRAWINGS. SEE SHEET
C13.0 FOR CONCRETE PAD
M
ATCH EXISTING
PAVEM
ENT EDG
E
24" VALLEY G
UTTER
18" RIBBON
CURB
18" RIBBON CURB
18" CURB AND GUTTER
CONCRETE SIDEWALK
2' WIDE - RADIAL DETECTABLE
WARNING SURFACE
24" VALLEY G
UTTER
RIBBON
CURB
18" RIBBON CURB
(TYP.)
8 8
WHEEL STOP
(TYP-5)
SEE H.C. PARKING
DETAIL FOR
STRIPING
GENERTOR
CONCRETE PAD
24" THERMOPLASTIC STOP BAR
24" THERMOPLASTIC STOP BAR
EXISTING LIVING QUARTERS
18" CURB AND GUTTER (TYP.)
C1
SEE CURVE
DATA THIS
SHEET
C2
DRIVE ℄
80.16'
M
ATCH EXISTING
PAVEM
ENT EDG
E
DRIVE ℄
24" THERMOPLASTIC
STOP BAR
GATE LOOP DETECTOR
GATE ACCESS PANEL WITH BOLLARDS
24' SLIDING
CANTILEVER GATE
2' WIDE CONCRETE
TROUGH FOR
GATE SLIDE
BOLLARD POST
(TYP-16)
8" THICK REINFORCED
CONCRETEPAVEMENT
12" HIG
H LETTERING
(THERM
O
PLASTIC) (TYPICAL
FO
R 2 LO
CATIO
NS)
FIRE HOSE BIB
CONCRETE PAD FOR 1 DERO BIKE
RACK (2 SPACES)
SEE SHEET C14.0 FOR DETAILS
10.00'
5.00'
.6
7'
7.
7.
9.
T Y
P
FIRE HYDRANT
FIRE DEPARTMENT
CONNECTION (FDC)
PEDESTAL
44.57'
8" THICK CRUSH-CRETE
6" SOLID
YELLOW STRIPE
10'
4H:1V
4H :1
V
4H :1
V
4H:1V
SEPTIC FIELD (CONSTRUCT
FOLLOWING THE DEMOLITION
OF EXISTING APPARTUS
GARAGE
21.08'
R1-1 STO
P SIG
N EAST FACING
W
ITH R5-1 DO
NO
T ENTER SIG
N
AND " EM
ERG
ENCY VEHICLE
EXIT" SIG
N O
N W
EST CR226
RO
AD SIDE O
F PO
LE (TYP.)
R1-1 STO
P SIG
N EAST FACING
W
ITH R5-1 DO
NO
T ENTER SIG
N
AND " EM
ERG
ENCY VEHICLE
EXIT" SIG
N O
N W
EST CR226
RO
AD SIDE O
F PO
LE (TYP.)
UNDERGROUND LP
TANK LOCATION
EV
CHARGER
93°23'34"
9.80'
67°21'12"
6.
XFRMR
CONCRETE PAD
MAN GATE W/
CARD READER
FLAG POLE
10.00'
.0
0'
8.50'
R5.00'
SEE SHEET C15.1
FOR FENCE
DETAILS
.0
0'
9.
.0 0'
8.
18.00' 6.00'
4.
.5
0' 8.
.5
0'
.3 7'
.3
7'
R
.0 0'
R51.00'
R31.00'
72.00' (DROP CURB)
6.00'
7.
22.00'
18.00' 12.00' 12.00' 18.00'
24.00'
5.00'
266.03' 27.67'
.0
0'
S
P
.0
O .C
.2 2'
.0
0'
.0 0'
9.
T
Y P
12.00' 12.00' 18.00'
R15.00'
R14 .00
R14.00'
R30.00'
.0
0'
.0
0'
.0 0'
.3
7'
79.33'
97.34'
75.50'
FUTURE BUILDING EXPANSION
FUTURE
BLDG
EXPANSION
53°0'0"
27°39'44"
45.59'
31.58'
59.25'
R
.0 0'
297.03'
27.34'
.3
3'
.8
3'
R28.00'
106°18'0"
25.67' 144.67'
6.00' 16.00'
.0
0' 7.
AERATION AND
FILTERING TANKS
FIRE PUMP WELL
WELL HOUSE W/ FIRE PUMP AND ELECTRICAL
DOMESTIC & IRRIGATION
WATER WELL
R12.00'
.3
3'
R18.00'
9.
5.50'
DOMESTIC WELL & PUMP
R50.00'
3.
R4.00'
264.33'
8.00'
MONUMENT SIGN.
SEE ARCHITECTURAL
SHEETS
R31.00'
10.00'
SEE ARCHITECTURAL
PLANS FOR THIS AREA
4.00'
2.00'
2.00'
.0
0' 9.
.0
0' 9.
(T Y
P
.0
0'
.0 0'
.0
0' 5.
9.
9.
.5
0'
24.00'
R3.
R 3.50'
.3
7'
55.00'
18.00'
.2
2'
99.44'
R 20.00'
97°0'0"
78°14'9" 60.86'
R19.00'
R 8.
R19 .0
0'
R24.00'
53.26'
.0
0'
.0
0'
18.00'
R4.50'
02/17/2026
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M
22003
6/23/2023
C O
UN
TY
R O
A D
G
RE
EN
C
O V
E
SP
RI
N
G S, F L
BID DOCUMENTS
C
LA
Y C
O
UN
TY
C
LA
Y C
O F
IR
E
ST
A
TI
O
N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
REVISIONS
# DATE DESCRIPTION
JEFFREY E. BERGEN, PE
THIS ITEM HAS BEEN ELECTRONICALLY
SIGNED AND SEALED BY
JEFFREY E. BERGEN, PE ON
USING A SHA AUTHENTICATION CODE.
PRINTED COPIES OF THIS DOCUMENT
ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SHA
AUTHENTICATION CODE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
PERMIT SET
GRADING AND
DRAINAGE
PLAN PHASE 1
C10.0
SCALE IN FEET
20 10 20
DRAINAGE LEGEND
PAVEMENT SPOT ELEVATION
EXISTING SPOT ELEVATION
GROUND ELEVATION
65.35
65.20 64.70
65.0
51.00 (ME)
TOP OF CURB OR SIDEWALK/
EDGE OF PAVEMENT
APPROX. ELEVATION - MATCH EXISTING
NOTES:
1. UNLESS OTHERWISE NOTED, INSTALL
CONCRETE SPLASH BLOCKS AT ALL ROOF
DRAIN DOWNSPOUTS
2. COORDINATE ALL EARTHWORK ACTIVITIES
WITH GEOTHECNICAL AND
ENVIRONMENTAL REPORTS
3. ALL DISTURBED AREAS SHALL BE SODDED
WITH BAHIA SOD, UNLESS OTHERWISE
NOTED ON THE LANDSCAPE PLAN.
4. ALL SIDEWALKS HAVE A MINIMUM 2' WIDE
SHOULDER WITH SLOPE MATCHING
SIDEWALK CROSS SLOPE.
5. ALL CLEANOUTS IN VEHICLE USE AREAS
SHALL HAVE H20 RATED COVERS.
6. THE STORM DRAIN SYSTEM IS REQUIRED
TO BE TELEVISE INSPECTED.1-800-432-4770
BEFORE YOU DIG !
CALL SUNSHINE STATE ONE CALL OF FLORIDA
AT LEAST TWO FULL BUSINESS DAYS BEFORE
DIGGING OR DISTURBING EARTH
Know what's below.
before you dig.Call
R
65.40
65.3 TOP OF PAVEMENT OR SIDEWALK/
GROUND ELEVATION
XXXX
X X
X X
X X
X X
X X X X X X X
X X
X X
X X
X X
X
XX
W
DRAIN FIELD
TOP EL=64.0
W
W
W W
W W
W W
W
W W
PROPOSED
FIRE STATION
4 BAYS / 16,633 S.F.
(REFER TO ARCHITECTURAL PLANS FOR
EXACT BUILDING DIMENSIONS)
F.F.E. =65.50
3' CT
D O
N O
T EN
TER
D O
N O
T EN
TER
.23
.77
.60
.34
.66
.0351
.51
.56
.61
.70
.80
.46
.30
.23
.42
.77
.07
.99
.49
.23
.68
.75
.36
.81
.11
.38
.34
.42
.26
.94
.28
.37
.46
.58
.42
.62
.73
.04
.14
.93
.88
.50
.11
.3261 .15
.90
.54
.72
.61
.24
.06
.07
.64
.33
.92
.02
.41
.15
.08
.55
.19
.35
.39
.50
.98
.69
.75
.19
.13
.39
.90
.06
.79
.21
.57
.77
.76
.23
.78
.23
.77
.60
.34
.66
.03
.89
.72
.22
.27
.85
.48
.7149
.82 .78
.10
.07
.70
.56
.56
.85
.71
.57
.08
.78
.13
.91
.08
.00
.22
.05
.99
.85
.70
.55
.37
.93
.58
.81
.26
.76
.86
.23
.36
.59
.3458 .79
.04
.99 58
.65
.64
.17
.15
.79
.51
.14
.89
.74
.63
.90
.02
.17
.39
.37
.15
.48
.07
.72
.91
.59
.23
.43
.54
.36
.18
.72
.61
.08
.75
.99
.50
.48
.49
.94
.79
.64
.75
.80
.85
.17
.62
.88
.75
.24
.62
.58
.91
.47
.63 .69
.79
.91 .93
.27
.02 .04
.99
.91
.85
.16
.42
.45
.60
.27
.80
.17
.11
.45
.90
.91
.14
.70
.60
.15
.33
.29
.92
.85
.80
.87
.31
.48
.97
.24
.97
.96
.73
.08
.99
.81
.12
.13
.05
.94
.84
.61
.08
.49
.39
.49
.90
.19
.55
.67
.51
.56
.61
.70
.80
.46
.30
.23
.42
.77
.07
.99
.49
.23
.68
.75
.36
.81
.11
.38
.34
.42
.26
.94
.28
.37
.46
.58
.42
.62
.73
.04
.14
.93
.88
.50
.11
.3261 .15
.90
.54
.72
.61
.24
.06
.07
.64
.33
.92
.02
.41
.15
.08
.55
.22
.15
.22
.63
.02
.93
.56
.59
.36
.35
.57
.66
.79
.31
.84
.17
.64
.29
.19
.35
.39
.50
.98
.69
.75
.19
.13
.39
.90
.06
.79
.21
.57
.77
.76
.23
.78
.89
.72
.98
.05
.21
.63
.31
.3765 .37
.22
.27
.85
.48
.7149
.82 .78
.10
.07
.70
.56
.56
.85
.71
.57
.08
.78
.13
.91
.08
.00
.22
.05
.99
.85
.70
.55
.37
.93
.58
.81
.26
.76
.86
.23
.36
.59
.3458 .79
.04
.99 58
.65
.64
.17
.15
.79
.51
.14
.89
.74
.63
.90
.02
.17
.39
.37
.15
.48
.07
.72
.91
.59
.23
.43
.54
.36
.18
.72
.61
.08
.75
.99
.50
.48
.49
.94
.79
.64
.75
.80
.85
.17
.62
.88
.75
.24
.62
.58
.91
.47
.63 .69
.79
.91 .93
.27
.02 .04
.99
.91
.85
.16
.42
.45
.60
.27
.80
.17
.11
.45
.90
.91
.14
.70
.60
.15
.33
.29
.92
.85
.80
.87
.31
.48
.97
.24
.97
.96
.73
.08
.99
.81
.12
.13
.05
.94
.84
.61
.08
.49
.39
.49
.90
.19
.55
.67
.92 .29
.03
.30 .31
.46
.4965
.42
.55
.31
.20
.64
.51
.68
.72
.95
.94
.03
.26
.31
.48
.49
.22
.15
.22
.63
.02
.93
.60
.67
.93
.98
.82
.83
.60
.46
.96
.88
.19
.90 .65
.84
.34
.39
.08
.01
.95
.74
.69
.16
.87
.63
.43
.76
.35 56
.76
.00
.36
.62
.07
.32
.87 65
.06
.40
.24
.48 56
.71 65 .44
.26 60
.89
.64 57
.45 .77
.45
.89 59
.44
.38
.56
.59
.00
.36
.35
.57
.66
.79
.31
.84
.17
.64
.29
.98
.05
.21
.63
.31
.3765 .37
.92 .29
.03
.30 .31
.46
.4965
.42
.55
.31
.20
.64
.51
.68
.72
.95
.94
.03
.26
.31
.48
.49
.60
.67
.93
.98
.82
.83
.60
.46
.96
.88
.19
.90 .65
.84
.34
.39
.08
.01
.95
.74
.69
.16
.87
.63
.43
.76
.35 56
.76
.00
.36
.62
.07
.32
.87 65
.06
.40
.24
.48 56
.71 65 .44
.26 60
.89
.64 57
.45 .77
.45
.89 59
.44
.38
.00
0 4 9 5
57 58 59
8 5 0 5 1 5
SWMF-1
6' CT
6' CT
3' CT
R A
M P
D O
W N
RAMP
DOWN
RAMP
DOWN
SWEAT ROAD
CO
UNTY RO
AD No. 226
SD
SD
3' CT
3' CT
.0
.051
.0
.0 52
.0
50.0
52.0
54.0
.0
3' CT
3'
CT
3' CT
3' CT
6' CT
RAMP
DOWN
HD
3' CT
3' CT
61.0 62.0 63.0
63.0
HD
HD
3' CT
W
CHK VLVE
50.70 (ME)
51.00 (ME)
50.86 (ME)
S-20
TYPE "E" INLET
GRATE EL. 50.90
INV. 47.46
.1
51.25
51.60
.10
S-13
CURB INLET
GRATE EL. 51.50
INV49.12 (SE)
INV48.40 (N)
S-12
CURB INLET
GRATE EL. 54.56
INV.51.38 (SE)
INV. 50.40 (NW)
S-11
CURB INLET
GRATE EL. 59.66
INV. 56.89 (SE)
INV. 53.20 (NW)
S-10
CURB INLET
GRATE EL. 63.85
INV. 59.00
S-19
MES (FDOT INDEX 430 - 022)
(WITH BARS)
INV. 47.40
S-21
MES (FDOT INDEX 430-022)
(WITH BARS)
INV. 47.51
S-6 CONTROL STRUCTURE (CS-1)
MOD. TYPE "H" INLET
GRATE EL. 52.33
INV.48.56 (E)
INV.48.18 (S)
INV.48.20 (W)
(SEE C.S. DETAIL, SHEET C15.0)
S-4
TYPE "E" INLET
GRATE EL. 60.91
INV. 57.97 (E)
INV. 53.80 (W)
INV. 58.24 (SW)
S-5
TYPE "E" INLET
GRATE EL. 55.83
INV.52.91 (E)
INV. 49.40 (N)
S-3
TYPE "E" INLET
GRATE EL. 63.90
INV.59.60
S-2
TYPE "C" INLET
GRATE EL. 63.80
INV.61.27
S -1
TYPE "C" INLET
GRATE EL.64.37
INV.61.50
65.0 65.0
65.0
65.3
65.0
65.50
.37
64.37
143 LF OF 15" HP PIPE @ 1.14 %
4H:1V TO EXIST./
PROPOSED GRADE
(TYP. UNLESS
OTHERWISE NOTED)
SLOPE NOT TO
EXCEED 5 %
3' SHOULDER
@ S = 2%
2.00'
SHOULDER
PROPERTY LINE
51.00
50.60
50.30 (ME)
51.3050.80
.45
.50
.50
.50
65.50
65.50
65.50
65.20
64.70 65.2064.70
65.50
65.50
.50
65.50
65.46
65.50
65.0 65.0
63.05
62.95
62.4562.77
62.27
62.5062.00 62.35
61.85
61.861.
61.24
61.2460.74 61.03
60.91
61.53
61.03
52.03
51.53
56.45
55.95
55.83 56.4555.95
62.07
64.0
65.10 64.60
65.30
64.80
64.76 64.26
63.90
64.60
64.10
63.85
59.66
60.05
59.90
57.65
57.50
57.76
57.26
74.00' (DROP CURB)
.63
.13
63.6063.10
63.47
.57
63.2162.71
63.50
63.50
63.50
64.2763.77
62.85 62.35
65.7565.25
64.8
65.06
64.9764.47
65.25
65.46
65.37 64.87
65.22
64.72
65.2264.72
.37
.0
.5
65.0064.50
64.97
64.47
65.37 64.87
.57
64.79 64.29
64.17
65.02 64.5264.40
64.
64.
64.4263.92
63.80
.20
64.8564.35
150 LF OF 15" HP PIPE @ 1.14 %
105 LF OF18" HP PIPE @ 0.85%
73LF OF 18" HP PIPE @ 0.85%
22 LF OF18" HP PIPE @ 0.21%
44 LF OF 15" HP PIPE
118 LF OF 15" HP PIPE
@ 1.55%
136 LF OF 15" HP PIPE @ 1.55%
50 LF OF 12"X18" WRCP @ 2.57%
55LF OF 24" X 38"
ERCP PIPE
155 LF OF 15" HP PIPE
@ 0.29 %
19 LF OF 24" HP PIPE
@ 0.1 %
56 LF OF 24" X 38"
ERCP PIPE
47 LF OF 24" X 38"
ERCP PIPE
117 LF OF 15" HP
PIPE @ 0.2%
33 LF OF 15" HP PIPE
S-7
TYPE "E" INLET
GRATE EL.52.50
INV. 48.02
(SEE DETAIL SHEET 14)
S-8
MES (FDOT INDEX 430-021)
SLOPE 4H:1V
INV. 48.00
S-18
MES (FDOT INDEX 430-022)
(WITH BARS)
INV.47.26
S-17
MES (FDOT INDEX 430-022)
(WITH BARS)
INV.47.20
S-14
TYPE "E" INLET
GRATE EL. 61.85
INV.58.50
.70
.20
65.50 65.00
.50 65.40
65.3
65.9665.46
.50
.4
.364.0
63.35
62.85
51.50
65.40
65.3
STRAIGHT GRADE DITCH (TYP.)
3' BOTTOM WIDTH DITCH
W / 4H:1V SIDE SLOPE ON ROAD
SIDE, 3H:1V SIDE SLOPE ON BACK
SIDE
3H:1V TO EXIST./
PROPOSED GRADE
(TYP. UNLESS
OTHERWISE NOTED)
65.72 65.22
65.42
65.35 65.3
65.3 65.3
.3
65.0
65.0
65.065.0
64.0 65.3
10.00'
SHOULDER
5.00'
SHOULDER
.0
.9
65.
65.0
.35 65.46
65.4
64.84
64.34 64.09
64.21
64.
64.
64.7164.21
64.5264.02
64.60
65.40
65.3
65.50
65.38 65.45 65.4
.7
62.3
.77
63.1
.5
65.0
65.50
65.48
.43
65.36
65.41
65.21
65.1
65.0
64.0
65.50
65.0
65.50
.0
64.7
64.28 63.78
12" PVC @
S = 4.34%
C.O.
INV. 62.15
C.O.
INV. 63.5
C.O.
INV. 63.20
ROOF DRAIN COLLECTOR
8" PVC SDR26 (TYP.) @ S = 1.0% (MIN.)
C.O.
INV. 62.55
ROOF DRAIN COLLECTOR
8" PVC SDR26 (TYP.) @ S = 1.0% (MIN.)
S-9
TYPE "C" INLET
GRATE EL. 64.0
INV. 61.00 (NE, NW)
INV. 59.26 (SW)
73 LF OF 12" HP PIPE
@ S = 0.35%
ROOF DRAIN COLLECTOR
8" PVC SDR26 (TYP.) @ S =
1.0% (MIN.)
C.O. (H20 RATED COVER)
INV. 62.35
C.O.
PEDESTRIAN / ADA RATED
CLEAN OUT LID / COVER
INV. 63.10 C.O. (H2O RATED COVER)
INV. 63.50
.4
65.50
4H:1V TO
EXIST. GRADE
SHOULDER /GRADE
BREAK LINE
65.46
GRADE BREAK
LINE
65.30
65.35 65.2
65.25
65.42
65.27
64.1563.65
62.80
.71
2' SHOULDER, THEN 4H:1V TO
EXISTING GRADE WITHIN
PROPERTY LIMITS
63.77
58.29
58.14
MATCH EXIST.
CONC. EL.
2' SHOULDER, THEN
4H:1V TO EXISTING
GRADE
61.15
MAX
SLOPE 2.0%
(DRY POND)
51.00
51.0
51.08
5.00' SHOULDER
64.0
63.9
33 LF OF18" HP PIPE @ 0.21%
S-22
STORM MANHOLE (SM)
TOP= 52.10
INV=48.10
10.00'
SHOULDER
61.0
62.0
.1
(M
E)
50.7
.5
51.0
50.5
51.0
3'H : 1'V
TO EXIST
GRADE
5.00'
SHOULDER
STRAIGHT
GRADE
5.00'
SHOULDER
STRAIGHT
GRADE
63.87
.3
63.8
54.56
.30
.80
64.0
60.50
60.00
64.0
.09
62.09
62.71 62.21
62.82
63.07
63.8363.3363 .07
.57
4H:1V TO EXIST./
PROPOSED GRADE
(TYP. UNLESS
OTHERWISE NOTED)
1' WIDE CONCRETE FLUME
63.40
62.90
63.3
63.4262.92
63.07
62.57
63.2462.84
63.47
.57
64.00
63.50
63.2162.71
63.8163.31
63.9363.43
64.1063.60
63.2
63.5
14.00'
65.0
64.75 64.95
.85
64.97
.9
1'
65.31
64.81
65.25
.4
64.03 64.20
.7
64.95
LESS THAN 5 %
SLOPE
LESS
THAN 2 %
SLOPE
64.0
02/17/2026
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M
22003
6/23/2023
C O
UN
TY
R O
A D
G
RE
EN
C
O V
E
SP
RI
N
G S, F L
BID DOCUMENTS
C
LA
Y C
O
UN
TY
C
LA
Y C
O F
IR
E
ST
A
TI
O
N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
REVISIONS
# DATE DESCRIPTION
JEFFREY E. BERGEN, PE
THIS ITEM HAS BEEN ELECTRONICALLY
SIGNED AND SEALED BY
JEFFREY E. BERGEN, PE ON
USING A SHA AUTHENTICATION CODE.
PRINTED COPIES OF THIS DOCUMENT
ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SHA
AUTHENTICATION CODE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
PERMIT SET
UTILITY PLAN
C12.0
SCALE IN FEET
20 10 20
WATER CONNECTION DETAIL SCALE: 1"=10'
NOTE: FIRE LINE GATE VALVE COVERS
SHALL BE PAINTED RED
GENERAL NOTES REGARDING WELLS:
THE WELLS FOR FIRE STATION 24 PROVIDE FOR THE STATION'S NEEDS REGARDING POTABLE WATER, IRRIGATION WATER, FIRE PROTECTION SYSTEMS, AS WELL AS FILLING THE COUNTY'S FIRE APPARATUS. AS SUCH, THE PLANS HAVE BEEN DEVELOPED TO MEET MULTIPLE CRITERIA INCLUDING PRESSURE, FLOW, REDUNDANCY, ETC. IT IS NOT OUR GOAL TO MANDATE SPECIFIC MANUFACTURERS OR MODELS OF WELL/PUMP COMPONENTS BUT RATHER
TO PROVIDE MINIMUM PERFORMANCE CRITERIA FOR THE WELL SYSTEMS.
THE GC IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL SYSTEM MEETING THE CRITERIA ESTABLISHED ON THE CIVIL AND FP DRAWINGS. BIDS ARE TO BE BASED ON THE SIZE OF THE WELLS AS INDICATED. DEPTH OF WELL IS TO BE DETERMINED BY THE GEOLOGY/HYDROLOGY OF THE SITE. ELECTRICAL SERVICE SHALL BE AS INDICATED ON ELECTRICAL DRAWINGS; PUMPS ARE TO BE SELECTED TO OPERATE USING THE INDICATED SERVICE SIZE/TYPE. SUBMITTALS ARE REQUIRED INDICTING ALL NECESSARY COMPONENTS OF A COMPLETE SYSTEM, COMPLIANT WITH THE APPLICABLE BUILDING CODES AND JURISDICTIONAL REQUIREMENTS FOR EACH
SYSTEM, INCLUDING, BUT NOT LIMITED TO:
· WELL(S)
· PUMP(S)
· CONTROL SYSTEMS
· PRESSURE BALANCING TANKS (BLADDER TANKS) OR OTHER MEANS OF REGULATING PRESSURE
· AERATION TANKS AND ASSOCIATED PUMPS
· COORDINATE WITH GC REGARDING PROVISIONS FOR PIPING, VALVES, BACKFLOWS, ETC.
ALTERNATES: FOLLOWING THE AWARD OF THE BID, THE A/E TEAM AND THE COUNTY WOULD BE RECEPTIVE TO
POTENTIAL VALUE ENGINEERING ALTERNATIVES REGARDING THESE WELL SYSTEMS.
XXXX
X X
X X
X X
X X
X X X X X X X
X X
X X
X X
X X
X
XX
W
S S
S
S
S
S S
DRAIN FIELD
TOP EL=64.0
W
W
W W
W W
W W
W
W W
PROPOSED
FIRE STATION
4 BAYS / 16,633 S.F.
(REFER TO ARCHITECTURAL PLANS FOR
EXACT BUILDING DIMENSIONS)
F.F.E. =65.50
R A
M P
D O
W N
RAMP
DOWN
SWEAT ROAD
RAMP
DOWN
W
CHK VLVE
SEE PUMBING PLAN
FOR CONTINUATION
CLEAN OUT (C.O.)
(H20 TRAFFIC RATED)
INV. 62.65
6" PVC SDR26
@ S=0.7% MIN.
6" PVC SDR 26 @
S=0.7% MIN.
C.O.
INV. 60.40
C.O.
INV. 63.06
3" PVC SDR 26
@ S=2.0%
GREASE TRAP (GT)
SEE CCUA STANDARD DETAILS ON
SHEET S-SEW
COVER EL= 64.40
4" INLET INV. 62.90 (IN)
4" OUTLET INV. 62.69 (OUT)
4" PVC SDR26 @ 2.0%
6"X6"X4" WYE
C.O.
INV. 61.13 6" PVC SDR 26@
S=0.7% MIN.
C.O.
(H20 TRAFFIC RATED)
INV. 62.03
OIL / WATER SEPARATOR (OWS)
COVER EL. 64.50
INV. (IN) 61.90
INV. (OUT) 61.40
1" PVC (SCH.40)
DOMESTIC WATER LINE
6" PVC SDR 26@ S=0.7% MIN.
6" PVC SDR 26@
S=0.7% MIN.
SEE WATER CONNECTION
DETAIL
THIS SHEET
PROPERTY LINE
(NOTE: SEE SEPTIC
SYSTEM PLAN / DETAILS
ENTIRE FOR SYSTEM)
ALL WEATHER, AUDIO-VISUAL
ALARM PANEL; FINAL LOCATION MAY
VARY
13 LF OF 2"
FORCEMAIN
14 LF OF 2" FORCEMAIN
EACH HEADER
MANIFOLD TO BE 16.5 LF
OF 2" DIA. SCH 40 PVC
EACH OF TWO (2) DRAINFIELDS TO HAVE
6 ROWS OF 14 CHAMBERS EQ36 Q4
INFILTRATORS FOR A TOTAL OF 84
CHAMBERS PER DRAINFIELD AND 168
CHAMBERS TOTAL
PROPOSED MIN 1900 GAL DOSING
TANK WITH DUPLEX LIFT STATION; SINGLE
CHAMBER TANK. TWO (2) - 12 HP EFLLUENT
PUMPS, EACH ALTERNATIVELY DOSING TO
EACH DRAINFIELD. CATEGORY 4 TANK
REQUIRED WITH RISERS AND SECURE LIDS
PROPOSED MIN 2700 GAL SEPTIC
TANK; DUAL CHAMBER. CATEGORY
4 TANK REQUIRED. INSTALL RISERS
WITH SECURE LIDS AND OUTLET
FILTER CAPABLE OF MIN. 1340 GPD
TREATMENT FLOW. PL-525 OUTLET
FILTER RECOMMENDED
46.00'
54.00'
56.00'64 .0
0'
PROPOSED 4' SHOULDERS AND
SLOPES AT 3:1 SLOPE RATIO
PROPOSED TWO (2) DRAINFIELDS, EACH 840 SQ.FT
TRENCH; LOW PRESSURE DOSED. EACH DRAINFIELD
TO HAVE PRESSURE LATERALS PER DESIGN
SPECIFICATIONS ON SEPTIC
PERMITTING AND TO BE ALTERNATIVELY DOSED BY
EACH OF TWO (2) EFFLUENT PUMPS. DO NOT LOOP
END OF DRAINFIELD; THIS IS A LOW PRESSURE
DOSED SYS
EXISTING
WELL TO BE
ABANDONED
4" 45° BEND
C.O.
INV.60.15
6" 45°
BEND
INV.=62.35
INV.=60.35
(2) 45° VERTICAL
BENDS TO 2'
VERTICAL GRADE
CHANGE
14.0'
R223'(WELL / SEPTIC DRAIN FIELD SEPARATION) (M
IN. 150')
120 GALLON UNDERGROUND LP TANK
LOCATION (GAS SUPPLY TO BE
PROVIDED BY GAS COMPANY,
COORDINATE WITH PLUMBING
CONNECTION POINT)
CROSSING PIPES WATER MAIN
UNDER STORM WATER DRAIN
MINIMUM PIPE COVER
SEPARATION NO LESS THAN 12"
PROPOSED HOSE BIB W/ CHECK VALVE .
HOSE BIB CAN BE WALL MOUNTED ON
DUMPSTER ENCLOSURE WALL
101' (100 M
IN.)
.0
0' (M
IN
X X X X X X X X X X X X X X
W
W
W W
S
W W
W W
W W W W W
W
W
W
W W
CHK VLVE
(2) 5" X 2.5" FLORIDAN AQUIFER DOMESTIC
WELLS EACH W/ A 5HP VARIABLE FREQUENCY
DRIVE, 230V, SINGLE PHASE, SUBMERSIBLE
PUMP PROVIDING 70 GPM @ 50 PSI. PUMPS
TO ALTERNATE & OPERATE IN A LEAD-LAG
SETUP TO PROVIDE BACKUP. VFD PUMPS TO
REPORT FAULT CONDITIONS VIA VISUAL
ALARM. VISUAL ALARM SIMILAR OR SAME AS
BUILDING PUMPS ALARM.
1" PVC (SCH.40)
DOMESTIC WATER
LINE
PROPOSED FIRE PROTECTION
PUMP W/ BLADDER STORAGE
TANK. 12" DIAMETER FLORIDIAN
AQUIFER WELL (SEE FIRE
PROTECTION PLANS FOR DETAIL &
PERFORMANCE SPECIFICATIONS)
3" TEE
FIRE RISER
6" PVC (DR18)
FREESTANDING
(PEDESTAL) FIRE
DEPARTMENT
CONNECTION (FDC)
CHECK VALVE
FIRE HYDRANT ASSEMBLY
GATE VALVE
4"X6" TAP/ TEE (DR18)
FIRE TRUCK
"FILL UP"
PEDESTAL / BIB
6" GATE VALVE
& BOX
(COVERS
PAINTED RED)
6" 90° ELBOW
(2) 500 GAL AERATION AND FILTERING TANKS. EACH
AERATOR TANK CONTAINS A 3HP VARIABLE
FREQUENCY DRIVE, 230V, SINGLE PHASE,
SUBMERSIBLE PUMP, PROVIDING 60 GPM @ 50 PSI,
WITH CHLORINE INJECTION SYSTEM. CONNECT BOTH
PUMPS TO A CONTROL PANEL SET UP TO
ALTERNATE PUMP USE & CONTROL VISUAL ALARM.
RED LIGHT VISUAL ALARM LOCATED ON FRONT OF
WELLHOUSE TO SIGNAL MALFUNCTION. SIGNAL TO
INCLUDE SIGNAGE
4" 90° BEND
2.5" GATE VALVE &
BOX (COVER
PAINTED RED)
2.5" PVC (SCH.40)
DOMESTIC
WATER LINE
6" TEE
3" RPZ
BFP
(INSULATED)
6" RPDA BFP
(INSULATED)
3" GATE
VALVE &
BOX
(TYP-3)
4" BEND
4" PVC (DR18)
6" PVC (DR18)
3" X1" REDUCER
IRRIGATION RPZ -BFP
(INSULATED)
2" PVC (SCH 40)
(IRRIGATION)
2" GATE VALVE
& BOX (3)
2" TEE
3" X 2.5"
REDUCER
4" GATE VALVE
AND BOX
3.00'
55.00'
3" PVC
(SCH.40)
2" PVC
(SCH.40)
.0
0' (M
IN
2",90°BEND
3", 90° BEND
6" 90°
BEND
90°BEND2" TEE
119 GAL TOTAL
VOLUME BLADDER
STORAGE TANK
85 GAL TOTAL
VOLUME BLADDER
STORAGE TANK
2" PVC (SCH.40)
4" PVC (DR18)
3" 90° BEND
4" PVC (DR18)
| Sheets and Views |
| C0.0 Cover-Layout1 |
| C0.1 Survey to print-Layout1 |
| C1.0 General Notes-Notes 1 |
| C2.0 General Notes-- |
| C3.0 LEGEND-Layout1 |
| C4-C5 PRE-POST DP-Layout1 |
| C4-C5 PRE-POST DP-Layout1 (2) |
| C6.0-C7.0 Demolition Plan-PH1 |
| C6.0-C7.0 Demolition Plan-PH2 |
| C8.0-C9-0 Geometry Plan-PH1 |
| C8.0-C9-0 Geometry Plan-PH2 |
| C9.A CONCRETE JOINT PLAN-C8.0A |
| C10-C11.0 Grading-PH1 |
| C10-C11.0 Grading-PH2 |
| C12.0 UTILITY Plan-UT |
| C13.0 Construction Details-- |
| C14.0 Drainage Details-Layout1 |
| C15.0 Misc. Details-Layout1 |
| C15.1 Fence DETAILS-Layout1 |
| C16.0 SEPTIC SYSTEM-- |
| C17.0 Well SYSTEMS 1 -- |
| C18.0 Well SYSTEMS 2-- |
| C19.0 MOT -- |
| C20.0 Storm Water PPP-Layout1 |
| C21.0 Erosion Control-C15.0 |
| C22.0 NPDES #1-- |
| C23.0 NPDES#2-- |
File details come from the government source that posted it. Updated .