Addendum_#1_-_Clay_Co_FS24_-_Landscape_(2026_02-17).pdf

PDF 2 MB Posted

Attached to
Construction of Clay County Fire Station No. 24
Solicitation number
25/26-042
Issued by
Clay County, Harold CDP, Florida

About this file

This is Addendum #1 to the landscape and irrigation design documents for Clay County Fire Station No. 24, located at 1075 County Road 226 in Green Cove Springs, Florida. The addendum revises the landscape plan (L1.1) and irrigation details (I2.1) documents dated January 2, 2026, incorporating changes effective February 17, 2026. The project encompasses comprehensive landscape and irrigation installation for the approximately 16,633-square-foot fire station facility on a 6.95-acre site. The landscape work includes site grading, sodding of all disturbed areas with Bahia sod, tree protection measures with barricading, and planting of specified ornamental vegetation. The irrigation system design provides 100 percent coverage of landscaped areas through a combination of spray heads, bubblers, and drip line systems operating from a well and pump system supplied by others, requiring a minimum flow of 20 gallons per minute at 50 pounds per square inch. The irrigation schedule specifies watering zones with operation on scheduled days, ranging from 12 to 14 minutes per zone with weekly precipitation rates between 1.44 and 1.78 inches per hour.

The irrigation system installation requires 2,502 linear feet of PVC Class 200 SDR 21 lateral piping installed 12 inches below final grade and 669.2 linear feet of mainline piping installed 18 inches below grade, along with 291.7 linear feet of Schedule 40 PVC sleeves for roadway and hardscape crossings. The contractor must install a Hunter HCC-800-PL eight-station wireless controller with touchscreen, Hunter HC-100 flow meter, Rain Sensor device, and color-coded direct burial control wiring per specifications. The design specifies Rain Bird bubblers and drip control kits with detailed valve schedules, pressure requirements, and friction loss calculations for each irrigation zone. The contractor is responsible for system startup, two pressure tests (2-hour test at 1.5 times static pressure and 24-hour test at system static pressure), provision of as-built drawings in PDF format, a color-coded zone diagram laminated sheet with electronic file copy, and a one-year warranty period including spring startup and adjustment. All materials must comply with applicable codes and ordinances, with the contractor required to verify compliance and notify the irrigation consultant of any required changes no later than five days before bid submittal.

View the file

Other files

File Type Posted
Construction_of_Clay_County_Fire_Station_No._24_(Addendum_#2_Revision).pdf PDF
Demolition_Asbestos_Survey_Report_.pdf PDF
Tile_Image_.jpg JPG image
07410-STANDING_SEAM_MTL_ROOFING_(Per_Addendum_1).pdf PDF
01260-CONTRACT_MOD_(per_Addendum_1).pdf PDF
01100_Owner_Furnished_Items_(Per_Addendum_1).pdf PDF
@TOC_(Per_Addendum_1).pdf PDF
266612-ASCO_ATS_ELEC_(per_Addendum_1).pdf PDF
Addendum_#1_-_266301-ELEC_TANK_SPEC_(per_Addendum_1).pdf PDF
Addendum_#1_-_266120-ELEC_GENSET_.pdf PDF
Addendum_#1_-_230000-HVAC_.pdf PDF
Addendum_#1_-_12511-Window_Blinds_.pdf PDF
Addendum_#1_-_11452-Appliances_.pdf PDF
Addendum_#1_-_10500-Mobile_PPE_Lockers_.pdf PDF
Addendum_#1_-_10425-Signs.pdf PDF
Addendum_#1_-_Clay_Co_FS24_-_Arch_(2026_02-17)_.pdf PDF
Addendum_#1_-_Clay_Co_FS_24_-_Plum_(2026_02-17)_.pdf PDF
Addendum_#1_-_Clay_Co_FS_24_-_Mech_(2026_02-17).pdf PDF
Addendum_#1_-_Clay_Co_FS_24_-_FP_(2026_02-17).pdf PDF
Addendum_#1_-_Clay_Co_FS_24_-_Civil_(2026_02-17)_.pdf PDF
Addendum_#1_-_Clay_Co_FS24_-_Struct_(2026_02-17).pdf PDF
Addendum_#1_-_Clay_Co_FS24_-_Elec_(2026_02-17).pdf PDF
Construction_of_Clay_County_Fire_Station_No._24.pdf PDF
Standard_Protection_Measures-Eastern_Indigo_Snake.pdf PDF
Indigo_Snake_Poster.pdf PDF
Clay_Co_Fire_Station_24_(2026_01-02)_Specifications-Bid_Set.pdf PDF
Clay_Co_FS24_AV_Documents_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Purvis_Documents_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Plumb_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Mech_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_FP_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Elec_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Struct_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Arch_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Landscape_Arch_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Civil_(2026_01-02)_Bid_Set.pdf PDF
Owner_Direct_Purchase_Program.pdf PDF
Appendix_II_for_2_CFR_Part_200.pdf PDF
FEMA_Field_Manual.pdf PDF
Subgrant-Agreement-226-SR-DR-4283-Executed-Funding-Agreement-Clay-County-460634-53096.pdf PDF
W-9_(2024).pdf PDF
Certificate_of_final_payment.pdf PDF
Certificate_of_partial_payment.pdf PDF
Chapter_8_Section_I.pdf PDF
EFT_FORM.pdf PDF
Warranty_Letter_.pdf PDF
Performance_&_Paymt_Bond.doc DOC document
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

XXXX

X X

X X

X X

X X

X X X X X X X

X X

X X

X X

X X

X

XX

W

SF

W

W

W W

W W

W W

W

W W

BO

T.

8.

BO

T.

8.

BOT. 48.0

3' CT

D O

N O

T EN

TER

D O

N O

T EN

TER

SWMF-1

6' CT

6' CT

3' CT

R A M P

D O W N

RAMP

DOWN

RA

MP

DO

WN

SWEAT ROAD

CO

UNTY RO

AD No. 226

.0

.0

.0 52

.0

.0

50.0

52.0

54.0

.0

.0

3' CT

3' CT

3' CT

3'

CT

3' CT

3' CT

6' CT

RAMP

DOWN

3' CT

3' CT

61.0 62.0 63.0

63.0

TOB 52.5

.0

.0

.0

.0

.0

.0

3' CT

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SFSFSF

SFSFSFSFSFSFSF

W

CHK VLVE

M

AT

C H

LI

N

E L1

.2 M

AT

C

H

LI

N E

L1 .1

640' COMPLIMENTARY

4'

R .O

.W

M

IN

U S

D R

IV

ES

432' COMPLIMENTARY

(4) QS

ALL DISTURBED AREAS SHALL BE

SODDED WITH BAHIA SOD

(3) QV

(5) LM

(14) MCA

(25) RAP

(15) IVO

(8) IVO

(5) ZFL

(6) ZFL

(12) IVO

(51) VOB

(3) QV

(61) VOB

FIRE STATION #24

(1) QV

(5) QS

(9) JV

ALL DISTURBED AREAS SHALL BE

SODDED WITH BAHIA SOD

TREE BARRICADE

-SEE DETAIL L2.1

TREE BARRICADE

-SEE DETAIL L2.1

TREE BARRICADE

-SEE DETAIL L2.1

20 401002040 10 0

DATE:

PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M

22003

06.23.2023

C O

UN

TY

R O

A D

BID DOCUMENTS

C

LA

Y C

O

UN

TY

C

LA

Y C

O F

IR

E

ST

A

TIO

N

STRUCTURAL ENGINEER

G.M. HILL ENGINEERING,

INC.

9700 PHILIPS HWY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

CIVIL ENGINEER

GOODSON BERGEN &

ASSOC

11555 CENTRAL PARKWAY, SUITE 103

JACKSONVILLE, FL 32224

REVISIONS

# DATE DESCRIPTION

FL6666918

MARGARET E. GAFFNEY-COOKE, RLA

L1.1

LANDSCAPE

PLAN

1/02/20262 90% V2 IRC REV

2/17/20263 ADD #1

XXXX

X X

X X

X X

X X

X X X X X X X

X X

X X

X X

X X

X

XX

W

SF

W

W

W W

W W

W W

W

W W

BO

T.

8.

BO

T.

8.

BOT. 48.0

3' CT

D O

N O

T EN

TER

D O

N O

T EN

TER

SWMF-1

6' CT

6' CT

3' CT

R A M P

D O W N

RAMP

DOWN

RA

MP

DO

WN

SWEAT ROAD

CO

UNTY RO

AD No. 226

.0

.0

.0 52

.0

.0

50.0

52.0

54.0

.0

.0

3' CT

3' CT

3' CT

3'

CT

3' CT

3' CT

6' CT

RAMP

DOWN

3' CT

3' CT

61.0 62.0 63.0

63.0

TOB 52.5

.0

.0

.0

.0

.0

.0

3' CT

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SFSFSF

SFSFSFSFSFSFSF

W

CHK VLVE

1"

2D9

2"

2E 6 1"

4 8.58 1"

314.4

2"

4"

4"

1"

1"

2"2"

2"

4"

4"

2"

2"

2"

4"

2"

1"

CRS

FM

POC

4"

4"

POINT OF CONNECTION TO THE PUMP

STATION, PROVIDED BY OTHERS.

APPROXIMATE IRRIGATION CONTROLLER AND SENSOR

LOCATION. OWNERS REPRESENTATIVE SHALL PINPOINT EXACT

LOCATION AT SITE. IRRIGATION CONTRACTOR SHALL HARDWIRE

120 VAC POWER TO CONTROLLER. RAIN SENSOR DEVICE IS TO

BE MOUNTED WHERE IT WILL BE EXPOSED TO UNOBSTRUCTED

RAINFALL, BUT NOT IN THE PATH OF SPRINKLER SPRAY.

9-12 DRIPLINE, INSTALLED

IN 12" ROWS (TYP).

TREE PROTECTION AREA

IRRIGATION CONTRACTOR IS TO AVOID

DISTURBING THE CRITICAL ROOT ZONE OF

ALL EXISTING TREES TO REMAIN. EXERCISE

CARE AND HAND TRENCH ONLY WITHIN

THE DRIP LINE OF .

4"

4"

F

F

F

D

D

D

D

F

2"1"

4"

4"

1"

4"

4"

1"

4"

4"

4"

2"

2"

2"

4"

2"

4"

4"

DATE:

PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M

22003

06.23.2023

C O

UN

TY

R O

A D

BID DOCUMENTS

C

LA

Y C

O

UN

TY

C

LA

Y C

O F

IR

E

ST

A

TIO

N

STRUCTURAL ENGINEER

G.M. HILL ENGINEERING,

INC.

9700 PHILIPS HWY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

CIVIL ENGINEER

GOODSON BERGEN &

ASSOC

11555 CENTRAL PARKWAY, SUITE 103

JACKSONVILLE, FL 32224

REVISIONS

# DATE DESCRIPTION

FL6666918

MARGARET E. GAFFNEY-COOKE, RLA

I1.1

LANDSCAPE

PLAN

20 401002040 10 0

BEFORE YOU DIG !

CALL SUNSHINE STATE ONE CALL OF FLORIDA

AT LEAST TWO FULL BUSINESS DAYS BEFORE

DIGGING OR DISTURBING EARTH

Know what's below.

before you dig.Callwww.callsunshine.com

THESE PLANS ARE DIAGRAMMATIC OF THE WORK TO BE PERFORMED. ALL LANDSCAPED

AREAS ARE TO RECEIVED 100% COVERAGE. INSTALL THIS IRRIGATION SYSTEM PER THE SITE

CONDITIONS, AVAILABLE FLOW/PRESSURE AND MANUFACTURERS RECOMMENDATIONS.

ADJUST ZONE FLOWS TO ACCOMMODATE THE AVAILABLE MAINLINE FLOWS AND PRESSURES.

THE DESIGN PROFESSIONAL DOES NOT ACCEPT ANY/ALL RESPONSIBILITY AND/OR LIABILITY

FOR PROBLEMS WHICH ARISE FROM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS AND

DESIGN INTENT THEY CONVEY OR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO

OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONALS GUIDANCE WITH RESPECT TO ANY

ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED.

- CONTRACTOR SHALL LOCATE ALL PROPERTY AND RIGHT OF WAY LINES BEFORE CONSTRUCTION BEGINS.

- THESE IRRIGATION PLANS ARE SCHEMATIC AND MAY BE EXAGGERATED. CONTRACTOR SHALL KEEP WITHIN ALL PROPERTY

AND RIGHT OF WAY LINES DURING CONSTRUCTION.

- CONTRACTOR SHALL ADJUST ALL SPRAY HEADS SO AS NOT TO SPRAY ONTO IMPERVIOUS SURFACES.

- CONTRACTOR SHALL LOCATE AND VERIFY ALL EXISTING UTILITY DEPTHS AND COORDINATE IRRIGATION CONSTRUCTION

WITH ALL EXISTING AND PROPOSED UTILITIES.

- ALL UNDERGROUND SLEEVES SHALL BE SCHEDULE 40 PVC AND SHALL BE TWICE THE DIAMETER OF ANY LINE IT HOUSES.

- CONTRACTOR TO PROTECT ALL EXISTING LANDSCAPING AND IRRIGATION.

- ALL WIRE WILL BE COLOR-CODED DIRECT BURIAL UL/LF WIRE: COMMON (WHITE) #12-1, CONTROL WIRE (RED) #14-1.

- IRRIGATION INSTALLATION CONTRACTOR SHALL INSTALL (2) SPARE CONTROL WIRES, COLOR-CODED YELLOW AND COMMON

FROM CONTROLLER TO MIDPOINT OF MAINLINE, MOUNTED IN 10" ROUND VALVE BOX.

NOTES

1/02/20262 90% V2 IRC REV

DATE:

PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M

22003

06.23.2023

C O

UN

TY

R O

A D

BID DOCUMENTS

C

LA

Y C

O

UN

TY

C

LA

Y C

O F

IR

E

ST

A

TIO

N

STRUCTURAL ENGINEER

G.M. HILL ENGINEERING,

INC.

9700 PHILIPS HWY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

CIVIL ENGINEER

GOODSON BERGEN &

ASSOC

11555 CENTRAL PARKWAY, SUITE 103

JACKSONVILLE, FL 32224

REVISIONS

# DATE DESCRIPTION

FL6666918

MARGARET E. GAFFNEY-COOKE, RLA

I2.1

IRRIGATION

DETAILS

1. IRRIGATION SYSTEM IS DESIGNED TO OPERATE OFF A WELL & PUMP SYSTEM, BY OTHERS. THE IRRIGATION

SYSTEM REQUIRES A MINIMUM FLOW OF 20 GPM AND A MINIMUM PRESSURE OF 50 PSI.

CONTRACTOR MUST CONTACT THE LANDSCAPE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY

CONSTRUCTION IF THE AVAILABLE FLOW AND PRESSURE DEVIATES MORE THEN 5% OR WILL AFFECT THE

PERFORMANCE OF THE SYSTEM.

2. HEAD LAYOUT IS BASED ON BASE INFORMATION PROVIDED. HEADS SHALL BE ADJUSTED TO ACCOMMODATE FIELD VARIATIONS WHILE MAINTAINING 100% COVERAGE AND MINIMIZING OVER-SPRAY ONTO PAVED AREAS AND

BUILDINGS.

3. 1/2" PIPE SHALL NOT BE USED FOR LATERAL PIPING.

IRRIGATION SYSTEM PERFORMANCE NOTES

SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI

Rain Bird 1800-1400 Flood Fixed flow rate 0.25 GPM - 2.0 GPM, full circle bubbler, 1/2in.

FIPT.

58 30

SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY

Rain Bird XCZ-100-PRB-R Wide Flow Drip Control Kit for Commercial Applications. Purple Cap designates for Reclaimed Water, Non-Potable Use. 1in.

PESBR Valve and 1in. Pressure Regulating 40psi Basket Filter.

0.3-20 GPM.

Rain Bird XCZ-150-LCDR High Flow Control Zone Kit, for Large Commercial Drip Zones.

1-1/2n. PESB-R Scrubber Globe Valve with single 1-1/2n.

Pressure Regulating 40psi Quick-Check Basket Filters. Flow range: 15-62 GPM.

Rain Bird MDCFCAP Dripline Flush Valve cap in compression fitting coupler. 4

Rain Bird OPERIND Drip System Operation Indicator, stem rises 6in. for clear visibility when drip system is charged to a minimum of 20psi. Includes 16in. of 1/4in. distribution tubing with connection fitting pre-installed.

Area to Receive Dripline Rain Bird XFD-09-12 XFD On-Surface Pressure Compensating Landscape Dripline. 0.9 GPH emitters at 12" O.C. Dripline laterals spaced at 12" apart, with emitters offset for triangular pattern. UV Resistant. Specify XF insert fittings.

1,530 lf

SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY

Rain Bird PESB 1", 1-1/2", 2" Plastic Industrial Valves. Low Flow Operating Capability, Globe Configuration. With Scrubber Technology for Reliable Performance in Dirty Water Irrigation Applications.

Nibco T-113-K Class 125 bronze gate shut off valve with cross handle, same size as mainline pipe diameter at valve location. Size Range - 1/4in. - 3in.

Hunter HCC-800-PL 8 Station Outdoor Wi-Fi enabled, full-functioning controller with touchscreen, Commercial Use. Plastic Cabinet.

Hunter RAIN-CLIK Rain Sensor, with conduit installation, mount as noted. Normally closed switch.

Hunter HC-100-FLOW 1in. Flow meter for use with Hydrawise enabled controller to monitor flow and provide system alerts. Also functions as stand alone flow totalizer/sub meter on any residential or commercial irrigation system.

Point of Connection System requires 20 GPM at 50 PSI. The Contractor shall coordinate the location with the Owner or General Contractor.

Irrigation Lateral Line: PVC Class 200 SDR 21 Only lateral transition pipe sizes 1" and above are indicated on the plan, with all others being 3/4" in size. Fittings shall be SCH 40 and molded. Install 12" below final grade.

2,502 lf

Irrigation Mainline: PVC Class 200 SDR 21 Pipe sizes 3" inch or smaller shall have bell and socket joints.

Fittings shall be SCH 40 and molded. Install 18" below grade.

669.2 lf

Pipe Sleeve: PVC Schedule 40 Irrigation sleeves shall be Schedule 40 PVC pipe up to 4” pipe.

The depth of the sleeves shall be a minimum 30” cover from finished grade (top of asphalt) under roadway crossings and 24" under all sidewalks and hardscapes.

291.7 lf

1408140414021401

F

D

C

RS

FM

POC

Valve Number

Valve Size

Valve Flow

Valve Callout

IRRIGATION SCHEDULE

NUMBER MODEL SIZE TYPE GPM HEADS PIPE 3/4" PIPE 1" PIPE 1 1/4" WIRE DESIGN PSI FRICTION LOSS VALVE LOSS PSI PSI @ POC PRECIP

1 Rain Bird PESB 1" Bubbler 14 28 611.3 286.9 115.7 189.9 30 6.63 2.24 38.9 40.4 1.76 in/h 2a Rain Bird PESB 1-1/2" Bubbler 9 18 451.2 131.3 311.1 30 2.39 3.9 36.3 38.9 1.78 in/h 2b Rain Bird PESB 1" Bubbler 6 12 292.4 563.8 30 0.66 1.72 32.4 37.5 1.71 in/h 3 Rain Bird XCZ-150-LCDR 1-1/2" Area for Dripline 14.37 957.5 lf 359.6 54.4 58.0 317.3 30 2.19 6 38.2 40.9 1.45 in/h 4 Rain Bird XCZ-100-PRB-R 1" Area for Dripline 8.58 572.1 lf 141.4 568.7 30 1.84 11.6 43.4 48.6 1.44 in/h

Common Wire 680.2

VALVE SCHEDULE IRRIGATION USING A MICRO-SPRAY, MICRO-JET, DRIP OR

BUBBLER IRRIGATION SYSTEM IS ALLOWED ANYTIME.

1. ALL MAINLINES TO HAVE A MINIMUM OF 18" OF COVER. (CLASS 200 PVC PIPE).

2. ALL LATERAL AND SUB-MAIN PIPE TO HAVE A MINIMUM OF 12" OF COVER (CLASS 200 PVC PIPE).

3. NO ROCKS, BOULDER, OR OTHER EXTRANEOUS MATERIALS TO BE USED IN BACKFILLING OF TRENCH.

4. ALL PIPE TO BE INSTALLED AS PER MANUFACTURERS' SPECIFICATIONS.

5. ALL THREADED JOINTS TO BE COATED WITH TEFLON TAPE OR LIQUID TEFLON.

6. ALL LINES TO BE THOROUGHLY FLUSHED BEFORE INSTALLATION OF SPRINKLER HEADS.

7. SPRINKLER AND RELATED EQUIPMENT TO BE INSTALLED AS PER DETAILS.

8. ALL ELECTRICAL JOINTS TO BE MADE USING WATERPROOF CONNECTIONS AS SHOWN ON DETAILS.

9. ALL EQUIPMENT NOT SPECIFIED IN THE LEGEND SHALL BE DETERMINED AND FURNISHED BY THE CONTRACTOR.

10. NO ELECTRICAL CONNECTIONS SHALL BE MADE IN THE FIELD EXCEPT AT A VALVE CONTROL BOX OR ANOTHER

VALVE BOX SPECIFICALLY FOR CONNECTIONS.

11. ANY DISCREPANCY BETWEEN THIS SHEET AND OTHERS IN THIS SET MUST BE REFERRED TO THE IRRIGATION

CONSULTANT BY THE CONTRACTOR FOR CLARIFICATION BEFORE PRECEDING WITH THE WORK.

12. ALL 24 VOLT WIRE SHALL BE #12 UF/UL FOR COMMON WIRE, AND #14 UF/UL FOR CONTROL WIRES, DIRECT BURIAL, SOLID COPPER.

13. CONTRACTOR TO BE RESPONSIBLE FOR PROPER COVERAGE OF AREAS TO BE WATERED. i.e ADJUST HEADS WITH

INSUFFICIENT COVERAGE DUE TO BLOCKAGE BY EXISTING OR PROPOSED SITE FEATURES.

14. CONTRACTOR TO REFER TO LANDSCAPE PLAN TO KEEP SPRINKLER EQUIPMENT AND ACCESSORY MATERIAL

FROM INTERFERING WITH PROPER PLANTING, i.e VERIFY ROOT BALL SIZE FOR PLANTING.

15. CONTRACTOR SHALL PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN A VALVE BOX (WRAP AROUND

3/4" PIPE 12 TIMES.

16. SPRINKLERS IN LOW-LYING AREAS SHALL HAVE CHECK VALVES.

17. ALL SPRINKLERS TO BE MOUNTED ON FLEX PIPE - REFER TO DETAILS.

18. INSTALL DRIP LINE TUBING AND NON-PRESSURE LATERAL LEAD LINE PIPING IN LANDSCAPE AREAS AND

ADJACENT TO SELECTED PLANT MATERIAL AS SHOWN IN DETAILS.

19. CONTRACTOR SHALL UTILIZE VALVE I.D. TAGS ON ALL REMOTE CONTROL VALVES.

20. 24 VOLT WIRE SHALL BE COLOR CODE; COMMON-WHITE, CONTROL-RED.

21. CONTRACTOR SHALL INSTALL MANUFACTURERS' RECOMMENDED GROUNDING EQUIPMENT FOR POWER SUPPLY

AND VALVE OUTPUT WITH (2) 5/8" COPPER CLAD GROUND RODS.

22. CONTRACTOR SHALL INSTALL MANUFACTURERS' RECOMMENDATION ON FAULT GROUND AND LIGHTNING

PROTECTION.

23. CONTROLLER GROUNDING MUST BE PER ASIC REQUIREMENTS.

24. ALL MATERIAL TO BE SUPPLIED BY CONTRACTOR TO OWNER:

A. TWO WRENCHES FOR DISASSEMBLING AND ADJUSTING EACH TYPE OF SPRINKLER HEAD AND VALVE

SUPPLIED.

B. TWO KEYS FOR EACH OF THE AUTOMATIC CONTROLLERS.

C. TWO QUICK COUPLER KEYS WITH MATCHING HOSE SWIVELS.

26. SYSTEM IS DIAGRAMMATIC TO IMPROVE CLARITY. ALL MAINLINE PIPING, ELECTRIC VALVES AND WIRING ARE TO BE INSTALLED IN LANDSCAPED AREAS AND REFERENCE THE LANDSCAPE PLAN PRIOR TO THE INSTALLATION OF

PIPING TO AVOID CONTACT WITH PLANT MATERIALS EXISTING OR NEW.

27. CONTRACTOR TO ADD EXTENSION RISERS TO POP-UP HEADS WHEN NEEDED TO PROVIDE PROPER COVERAGE.

28. CONTRACTOR SHALL INSTALL SPRINKLER EQUIPMENT 18" FROM FOUNDATIONS, ALSO INSTALL SPRINKLERS 4"

FROM CURBS OR WALKS.

29. PRIOR TO BID IRRIGATION CONTRACTOR SHALL VERIFY RIGHT-OF-WAY AND BACKFLOW REQUIREMENTS NO

LATER THAN FIVE DAYS BEFORE BID SUBMITTALS. CONTRACTOR SHALL NOTIFY CONSULTANT OF ANY CHANGES

FROM PLANS OR SPECIFICATIONS.

30. IRRIGATION CONTRACTOR SHALL PROVIDE THE OWNER AND LANDSCAPE ARCHITECT WITH A REPRODUCIBLE AS-BUILT DRAWING OF THE INSTALLED IRRIGATION SYSTEM IN A PDF FILE FORMAT BEFORE FINAL ACCEPTANCE.

PROVIDE CROSS-MEASURED LOCATIONS OF ALL VALVE LOCATIONS, CONTROLLER, WATER SOURCE, WIRE

SPLICES, SLEEVE LOCATIONS, ETC.

31. A 1-YEAR WARRANTY PERIOD SHALL BE PROVIDED FOR SYSTEM AFTER SUBSTANTIAL COMPLETION IS ACCEPTED.

START UP AND ADJUSTING OF SYSTEM IN SPRING TIME SHALL BE INCLUDED IN WARRANTY.

32. PRIOR TO BID, CONTRACTOR SHALL VERIFY THAT ALL MATERIAL, INSTALLATION PARAMETERS AND OPERATIONS CONFORM TO ALL APPLICABLE CODES AND ORDINANCES NO LATER THAN FIVE DAYS BEFORE BID SUBMITTALS.

CONTRACTOR SHALL NOTIFY IRRIGATION CONSULTANT/DESIGNER OF ANY CHANGES REQUIRED DUE TO CURRENT CODE OR ORDINANCE DISCREPANCIES. IF CONTRACTOR DOES NOT COMPLY TO THIS NOTIFICATION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY INSTALLATION CHANGE AND REDESIGN COSTS

FOR NON-COMPLIANCE.

33. UNLESS OTHERWISE NOTED, THE CONTRACTOR MUST COMPLETE TWO PRESSURE TESTS OF THE IRRIGATION

SYSTEM MAINLINE(BOTH TO SHOW NO DROP IN PRESSURE DURING DURATION OF THE TEST).

A. 2-HOUR PRESSURE TEST AT 1.5 TIMES THE SYSTEM STATIC PRESSURE

B. 24-HOUR PRESSURE TEST AT THE SYSTEM STATIC PRESSURE

34. IRRIGATION INSTALLATION CONTRACTOR SHALL PROVIDE THE OWNER WITH A COLOR-CODED ZONE DIAGRAM PLAN, 8-1/2"X11" LAMINATED SHEET(S) WITH AN ELECTRONIC FILE COPY TO IDENTIFY CONTROLLER STATION TO THE CONTROL VALVE NUMBER FOR EACH CONTROLLER. THE LAMINATED CHART IS TO BE LOCATED IN AN

ADHESIVE POUCH ATTACHED TO THE INSIDE OF CONTROLLER(S).

35. THE CONTROLLER(S) SHALL SCHEDULE PROGRAM "A" TO A REGULAR RUN-TIME SETTINGS FOR AFTER THE ESTABLISHMENT PERIOD OF THE PLANT MATERIAL. PROGRAM "B" SHALL BE USED DURING THE ESTABLISHMENT

PERIOD AND TURNED OFF AFTER THE 30-60 DAYS OF PLANT INSTALLATION.

36. THE IRRIGATION CONTRACTOR WILL READ ALL SPECIFICATIONS AND REVIEW ALL DETAILS AND EXAMINE THESE PLANS CAREFULLY PRIOR TO BIDDING THIS PROJECT. FAILURE TO READ THIS INFORMATION IS NOT AN

ACCEPTABLE REASON IF THE JOB IS UNDERBID.

37. THE PLAN MAY NOT INCLUDE ALL MATERIALS. THIS DOESN'T RELIEVE THE CONTRACTOR FROM BEING

RESPONSIBLE TO PROVIDE A COMPLETE SYSTEM IN PERFECT WORKING ORDER.

GENERAL IRRIGATION NOTES10" ROUND VALVE BOX

8' COPPER CLAD GROUND ROD

50 OHMS OR LESS

CONNECTION

#6 to #10 BARE COPPER

GROUNDING CONDUCTOR

CONDUIT TO CONTROLLER5

GROUND PER N.E.C.

CONTROLLER GROUNDING

RAIN SENSOR ROOF BRACKET

MIN.

6"

SUPPLY &

MIN.

12"18"

6" 6"

EXHAUST

MIN.

DETAIL NOTES:

P.V.C. LATERAL

CONTROL WIRE

MAIN LINE AND

1. ALL P.V.C. PIPING SHALL BE SNAKED IN TRENCHES.

2. ALL WIRING TO BE BUNDLED AND TAPED AT 20' INTERVALS.

3. ALL MAIN SUPPLY LINES TO BE INSTALLED AS PER

MANUFACTURER'S SPECIFICATIONS.

4. PROVIDE PIPE AND WIRE SLEEVES UNDER ALL PAVED SURFACES.

WIRE SHALL BE WITHIN SEPARATE 2" ELECTRICAL CHASE.

5. CONTRACTOR TO COMPLY WITH ALL LOCAL CODES AND

ORDINANCES IN REFERENCE TO THE INSTALLATION OF PVC PIPING

6. TIE A LOOSE 20' LOOP IN WIRING AT ALL CHANGES OF DIRECTION

GREATER THAN 30° UNTIE ALL LOOPS AFTER ALL CONNECTIONS

HAVE BEEN COMPLETED

7. INSTALL #14-1 TRACKING WIRE NEXT TO MAINLINE

HEADERS

MIN.

12"

WIRE WITHIN

6"

CONDUIT

DRIP ZONE

TRENCHING DETAIL

5" WIDTH

(13 CM)

13.7"OPEN DOOR WIDTH

NOTES:

1. CONTROLLER ACCEPTS 120 VOLTS A.C. OR

230 VOLTS A.C. (INTERNATIONAL MODEL).

2. MOUNT CONTROLLER LCD SCREEN AT EYE

LEVEL, CONTROLLER SHALL BE HARD-WIRED

TO GROUNDED 110 VAC POWER SOURCE.

3. REFER TO THE HUNTER HCC INSTALLATION

GUIDE FOR FURTHER INSTRUCTIONS.

IRRIGATION CONTROLLER (HCC-800-PL)

IRRIGATION CONTROLLER (I2C-800-PL)

PER PLAN

IRRIGATION CONTROL WIRE IN CONDUIT

SIZE AND TYPE PER LOCAL CODES

ELECTRICAL SUPPLY CONDUIT

CONNECT TO POWER SOURCE, J-BOX

INSIDE CONTROLLER

ADJACENT SURFACE TO MOUNT

CONTROLLER PER PLAN

3FRONT ELEVATION

SIDE ELEVATION

FLOW

NOTE: INLET PIPE ENTERING METER: LENGTH MUST BE A MIN. OF 10 X PIPE DIA.

OUTLET PIPE LEAVING METER: LENGTH MUST BE MIN. OF 5 X PIPE DIA.

INLET AND OUTLET PIPE MUST BE STRAIGHT PIPE WITH NO FITTINGS OR TURNS

UNTIL AFTER THESE SPECIFIED LENGTHS. PIPE AND FITTINGS MAY BE SCH 80 PVC

SOLVENT WELD, THREADED SCH 80 PVC OR BRASS, AS REQUIRED FOR PROJECT.

HC-100 FLOW METER

6 2 9 8 2 10

7 5 74

1 6 4

7 5 7

HUNTER HC FLOW METER HC-100 WITH UNION

CONNECTIONS

SCH 80 PVC FEMALE ADAPTER (SXT)

RECTANGULAR VALVE BOX PER SPECIFICATIONS

SCH 80 PVC 45 DEGREE ELBOW (SXS) TO LOWER

MAINLINE TO PROPER DEPTH

SCH 80 PVC 45 DEGREE ELBOW (SXS) TO LOWER

MAINLINE TO PROPER DEPTH

1.5" DIA MAINLINE AT INLET AND OUTLET

MAIN LINE TO SYSTEM

TWO WIRES TO FLOW SENSOR TERMINALS AT

CONTROLLER. MIN. 18 AWG-UP SHIELDED WIRE

WEATHERPROOF WIRE CONNECTOR

FINISH GRADE

SPECIFIED SOIL COVER

COMMON BRICK

GRAVEL BASE, 6" DEEP

TOP VIEW

10X PIPE DIA. 5X PIPE DIA

NUMBER MODEL TYPE PRECIP SUN MON TUE WED THU FRI SAT IN./WEEK MIN./WEEK GAL./WEEK GAL./DAY

1 Rain Bird PESB Bubbler 1.76 in/h 12 min 12 min 12 min 1 35 490 163 2a Rain Bird PESB Bubbler 1.78 in/h 12 min 12 min 12 min 1 34 306 102 2b Rain Bird PESB Bubbler 1.71 in/h 12 min 12 min 12 min 1 36 216 72 3 Rain Bird XCZ-150-LCDR Area for Dripline 1.45 in/h 14 min 14 min 14 min 1 42 604 201 4 Rain Bird XCZ-100-PRB-R Area for Dripline 1.44 in/h 14 min 14 min 14 min 1 42 360 120

TOTALS: 64 64 64 189 1,976 658.6

WATERING SCHEDULE

Sheets and Views
I2.2

File details come from the government source that posted it. Updated .