Addendum_#1_-_Clay_Co_FS24_-_Arch_(2026_02-17)_.pdf
PDF 17 MB Posted
- Attached to
- Construction of Clay County Fire Station No. 24
- Solicitation number
- 25/26-042
- Issued by
- Clay County, Harold CDP, Florida
About this file
Addendum #1 to Clay County Fire Station No. 24 Architectural and Engineering Documents
This addendum document, dated February 17, 2026, supplements the bid documents prepared by Dasher Hurst Architects, P.A. for the Clay County Board of County Commissioners' construction of Fire Station No. 24 located at 1075 County Road 226 in Green Cove Springs, Florida. The project involves the construction of approximately 16,633 square feet of new fire station facilities on a 6.95-acre site, encompassing four apparatus bays, administrative offices, living quarters for firefighters, training and fitness areas, kitchen and dining facilities, multiple restrooms and shower rooms, and support spaces. The project requires coordination among multiple engineering disciplines: structural engineering by G.M. Hill Engineering, Inc.; mechanical, electrical, and plumbing (MEP) design by Powell & Hinkle Engineering, P.A.; and civil engineering by Goodson Bergen & Associates. The addendum includes architectural and engineering drawings demonstrating site plans, floor plans with dimensional and finish specifications, roof plans with details regarding standing seam metal roofing and TPO low-slope roofing systems, wall sections, and miscellaneous exterior and interior details. Key architectural features include concrete masonry unit (CMU) construction with both split-face and polished finishes, prefabricated aluminum canopies, aluminum storefront systems, ceramic and porcelain tile flooring and wall applications, custom millwork including kitchen cabinetry with quartz countertops, and specialized equipment installations such as SCBA compressor systems, vehicle exhaust systems, and ice machines. The mandatory pre-bid meeting was scheduled for February 6, 2026, at 10:00 a.m. on-site, with inquiries due by February 13, 2026, at 4:30 p.m. through the County's e-Procurement Portal, and sealed bids due electronically by March 2, 2026, at 4:00 p.m., with bid opening on March 3, 2026, at 9:00 a.m. Substantial completion is required by March 15, 2027, and final Certificate of Occupancy by March 20, 2027.
The project is subject to Davis-Bacon Act prevailing wage requirements and compliance with federal regulations including 2 CFR Part 200 due to funding support from the Federal Emergency Management Agency (FEMA) Public Assistance Grant Program. All bidders must be Florida-licensed General Contractors with a minimum of five years' experience performing similar work and must be in good standing with the Florida Construction Industry Licensing Board and the State of Florida Department of State, Division of Corporations. Bidding requirements include a five percent bid bond, 100 percent Performance and Payment Bond per Florida Statute 255.05, and comprehensive insurance including Commercial General Liability of $1,000,000 per occurrence and $2,000,000 aggregate, Workers' Compensation at statutory limits, and Builder's Risk coverage equal to 100 percent of project value with a maximum $25,000 deductible. Liquidated damages of $1,000 per day are assessed for delays beyond the final completion date. The project site contains protected species including Eastern Indigo Snakes and Tri-Colored Bats, requiring implementation of specific protective measures coordinated with qualified environmental professionals and compliance with Florida Fish and Wildlife Conservation Commission and U.S. Fish and Wildlife Service guidelines, with violations carrying civil penalties up to $25,000 and criminal penalties up to $50,000 and/or imprisonment. The County reserves the right to approve all subcontractors and may utilize a Direct Purchase Program to procure major materials directly, with County purchases deducted from the contract price. No specific project budget or award value is disclosed in available documentation; however, the comprehensive scope spanning structural, MEP, civil, landscape, fire protection, and specialized systems indicates a substantial public infrastructure investment. A strict no-contact rule prohibits communications with Board members, County employees, evaluation committee members, or County agents regarding the Request for Bid from publication through 72 hours after bid decision, with limited exceptions for inquiries submitted through the Purchasing Department, attendance at the pre-bid conference, and formal presentations to the Evaluation Committee.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DIMENSION LINE
DOOR TAG
WALL SECTION
REFERENCE
ELEVATION
REFERENCE
BUILDING SECTION
REFERENCE
WALL/DETAIL SECTION
REFERENCE
6' - 0"
ROOM TAG
GRID LABEL
CENTERLINE
CEILING
HEIGHT TAG
SYMBOLS DESCRIPTION
EARTH OR
COMPACTED FILL
CONCRETE
BRICK
CONCRETE
MASONRY UNIT
ALUMINUM
STEEL &
OTHER METALS
CONTINUOUS
WOOD FURRING
DISCONTINUOUS WOOD
BLOCKING OR SHIM
ORIENTED
STRAND BOARD
FINISH WOOD
BATT INSULATION
RIGID BOARD INSULATION
PORTLAND
CEMENT PLASTER
ON MTL LATH (STUCCO)
MATERIAL SYMBOLS DESCRIPTION
EXISTING UNRATED WALL
EXISTING 1-HOUR RATED WALL
EXISTING 2-HOUR RATED WALL
EXISTING 3-HOUR RATED WALL
EXISTING SMOKE RATED WALL
NEW UNRATED WALL
NEW 1-HOUR RATED WALL
NEW 2-HOUR RATED WALL
NEW 3-HOUR RATED WALL
NEW SMOKE RATED WALL
WALL DESIGNATIONS
Room name
HEIGHT
MATL
FINISH (IF APP'L)
E X
IS
T
N G
W A
L L S
A R
E S
H A
D E
D G
R A
Y
A
A301
A301
A301
A301
CL
A301
A401
CLEAR DIMENSION LINE
6' - 0"
101A
F
B
W
ROOM NAME
CPT-1
P-1
VB-1
ROOM TAG
W/ FINISHES
FLOOR FINISH
BASE FINISH
WALL FINISH
8'-0"
PT-1
ACT-1
PLYWOOD
ELEVATION LABEL
WALL TAG
SPOT ELEVATION -
SOLID DOT
DETERMINES POINT OF
MEASUREMENT
100'-0"
NORTH ARROW
GRAPHIC SCALE
REVISION CLOUD
AND TAG
DETAIL CALLOUT
SHEET SPECIFIC
KEYNOTE
0' 2' 4' 8'1'
S
N
EW
A6.01
S4A
CURTAIN WALL /
STOREFRONT TAG
FINISH FLOOR
0'-0"
MATERIAL TAG
08.3
MTL-1
SF
WINDOW TAGD
SHEET NUMBER WHERE
SECTION IS DRAWN
INDICATES TYPE
MULTI VIEW ELEVATION
REFERENCE
SF = STOREFRONT
ISF = INTERIOR STOREFRONT
AGE = ALL GLASS EXTERIOR
AGI = ALL GLASS INTERIOR
CW = CURTAIN WALL
SPRAY INSULATION
RIGID INSULATION
(TYP WALL HATCH - SMALL
SCALE PLANS)
BATT INSULATION
(TYP WALL HATCH - SMALL
SCALE PLANS)
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
PROJECT
INFO
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
G001
BID DOCUMENTS
C L A
Y C
O U
N
TY
C L A
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
DRAWING INDEX
PROJECT SITE
GENERAL NOTES
TYPICAL ABBREVIATIONSREFERENCE SYMBOLS
VICINITY MAP
GENERAL
G000 COVER SHEET
G001 PROJECT INFO
G002 ADA CLEARANCES
G003 PARTITION SCHEDULE
G100 CODE ANALYSIS
G101 LEVEL ONE - LIFE SAFETY PLAN
CIVIL
- CIVIL DRAWINGS
LANDSCAPE
-- LANDSCAPING DRAWINGS
IRRIGATION
--- IRRIGATION DRAWINGS
ARCHITECTURE
A100 ARCH SITE PLAN
A100a ARCH SITE PLAN W AERIAL
A100b ARCH SITE PLAN W/ TOPO
A101 FLOOR PLAN
A101a LEVEL ONE PLAN- COLOR
A102 FLOOR PLAN- DIMS
A103 FLOOR PLAN - FINISHES
A104 ROOF PLAN
A111 REFLECTED CLNG PLAN
A200 EXTERIOR PERSPECTIVE VIEWS
A201 ELEVATIONS
A202 ELEVATIONS
A203 ELEVATIONS
A301 BUILDING SECTIONS
A302 BUILDING SECTIONS
A311 WALL SECTIONS
A312 WALL SECTIONS
A313 WALL SECTIONS
A314 WALL SECTIONS
A401 ENLARGED PLANS
A402 SHEET REMOVED
A403 SHEET REMOVED
A501 MISC EXT DETAILS
A502 DETAILS - ROOFING
A503 DETAILS - ROOFING
A504 MISC EXT DETAILS
A601 FINISH SCHEDULE & LEGEND
A602 DOOR SCHEDULE
A603 GLAZING SCHEDULE
A604 DOOR & WINDOW DETAILS
A605 DOOR & WINDOW DETAILS
A700 INTERIOR PERSPECTIVES
A701 INTERIOR ELEVATIONS
A702 INTERIOR ELEVATIONS
A703 INTERIOR ELEVATIONS
A704 INTERIOR ELEVATONS
A801 MILLWORK DETAILS
A802 MILLWORK DETAILS
A803 MILLWORK DETAILS
A804 INTERIOR DETAILS
STRUCTURAL
S001 GENERAL NOTES
S002 GENERAL NOTES
S003 SCHEDULES
S004 WIND PRESSURE DIAGRAMS
S101 FOUNDATION & SLAB PLAN
S102 SHEET REMOVED
CSK: COUNTERSUNK
CT: CERAMIC TILE
DA: DOUBLE ACTING
DB: DECIBEL
DEPT: DEPARTMENT
DIAG: DIAGONAL
DIAM: DIAMETER
DIFF: DIFFUSER
DIM: DIMENSION
DISP: DISPENSER
DIV: DIVISION
DN: DOWN
DR: DOOR
DTL: DETAIL
DWG: DRAWING
DWGS: DRAWINGS
DX: DIRECT EXPANSION
E: EAST
EA: EACH
EJ: EXPANSION JOINT
ELECT: ELECTRICAL
E.M. ELEVATOR MACHINE
EQ: EQUAL
EW: EACH WAY
EXST: EXISTING
EXT: EXTERIOR
FAST: FASTENER, FASTEN
FD: FLOOR DRAIN
FE: FIRE EXTINGUISHER
FFE: FINISHED FLOOR ELEVATION
FIN: FINISH
FIXT: FIXTURE
FLR: FLOOR
FO: FINISHED OPENING
F.O. FACE OF
FTG: FOOTING
FURR: FURRING
FUT: FUTURE
FVC: FIRE VALVE CABINET
GA: GAUGE, GAGE
GAL: GALLON(S)
GALV: GALVANIZED
GC: GENERAL CONTRACTOR
GL: GLASS
GWB: GYPSUM WALL BOARD
HB: HOSE BIBB
HDR: HEADER
HDWR: HARDWARE
HEX: HEXAGONAL
HGR: HANGER
HM: HOLLOW METAL
HORZ: HORIZONTAL
HT: HEIGHT
HVAC: HEATING, VENTILATING & AIR COND'G
HW: HOT WATER
ID: INSIDE DIAMETER
INSUL: INSULATION
INT: INTERIOR
JT: JOINT
KPL: KICKPLATE
LAM: LAMINATE
LAV: LAVATORY
LGM: LIGHT GAUGE METAL
LVR: LOUVER
MACH: MACHINE
MATL: MATERIAL
MAX: MAXIMUM
MC: MEDICINE CABINET
MCP: METAL CEILING PANEL
MECH: MECHANICAL
MEP: MECHANICAL, ELECTRICAL, PLUMBING
MEZZ: MEZZANINE
MFD: MANUFACTURED
MFR: MANUFACTURE, MANUFACTURER
MH: MANHOLE
MIN: MINIMUM
MISC: MISCELLANEOUS
MM: MILLIMETER
MRL: MACHINE ROOMLESS ELEVATOR
MTD: MOUNTED
MTL: METAL
MULL: MULLION
N: NORTH
N/A: NOT APPLICABLE
NEC: NATIONAL ELECTRICAL CODE
NIC: NOT IN CONTRACT
NOM: NOMINAL
NR: NOISE REDUCTION
NRC: NOISE REDUCTION COEFFICIENT
NTS: NOT TO SCALE
OA: OUTSIDE AIR, OVERALL
OBS: OBSCURE
OC: ON CENTER
OD: OUTSIDE DIAMETER
OF: OUTSIDE FACE
OH: OVERHEAD
O.H.: OPPOSITE HAND
OHD: OVERHEAD DOOR
OPNG: OPENING
OPP: OPPOSITE
P: PAINT
PART: PARTITION
PERP: PERPENDICULAR
PFN: PREFINISHED
PL: PROPERTY LINE
PLAM: PLASTIC LAMINATE
PLBG: PLUMBING
PLYWD: PLYWOOD
PNL: PANEL
PR: PAIR
PREFAB: PREFABRICATED
PSF: POUNDS PER SQUARE FOOT
PSI: POUNDS PER SQUARE INCH
PT: PRESSURE TREATED
PTD: PAPER TOWEL DISPENSER
PVG: PAVING
PVMT: PAVEMENT
QT: QUARRY TILE
QTR: QUARTER
QTY: QUANTITY
@ AT
& AND
" INCH
# NUMBER OR POUND
ᴓ DIAMETER, ROUND, PHASE
A/C AIR CONDITIONING
ACI: AMERICAN CONCRETE INSTITUTE
ACST: ACOUSTIC
ACT: ACOUSTICAL CEILING TILE
AESS: ARCHITECTURALLY EXPOSED STRUCTURAL STEEL
AD: AREA DRAIN
ADA: AMERICANS WITH DISABILITIES ACT
ADAAG: AMERICANS WITH DISABILITIES ACT GUIDELINES
AFF: ABOVE FINISHED FLOOR
AIA: AMERICAN INSTITUTE OF ARCHITECTS
AISC: AMERICAN INSTITUTE OF STEEL CONSTR
ALUM: ALUMINUM
AMP: AMPERE
ANCH: ANCHOR
ANOD: ANODIZED
AP: ACCESS PANEL
APPD: APPROVED
APPROX: APPROXIMATE
ASCE: AMERICAN SOCIETY OF CIVIL ENGINEERS
ASME: AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASPH: ASPHALT
ASSY: ASSEMBLY
ASTM: AMERICAN SOCIETY FOR TESTING AND MATLS
BD: BOARD
BEL: BELOW
BLDG: BUILDING
BLK: BLOCK
BLKG: BLOCKING
BM: BEAM
B.O.: BOTTOM OF
BPL: BEARING PLATE
BRG: BEARING
BTU: BRITISH THERMAL UNITS
BTUH: BRITISH THERMAL UNITS PER HOUR
BVL: BEVELLED
CAB: CABINET
CCW: COUNTER CLOCKWISE
CF: CUBIC FEET
CFL: COUNTERFLASHING
CFM: CUBIC FEET PER MINUTE
CH: COAT HOOK
CHR: CHILLED WATER RETURN
CHAM: CHAMFER
CHS: CHILLED WATER SUPPLY
CI: CAST IRON
CIP: CAST-IN-PLACE
CIRC: CIRCUMFERENCE
CJ: CONTROL JOINT
CL: CENTERLINE
CLG: CEILING
CLR: CLEAR
CLR OPG: CLEAR OPENING
CMU: CONCRETE MASONRY UNIT
COL: COLUMN
CONC: CONCRETE
COND: CONDITION
CONST: CONSTRUCTION
CONT: CONTINUOUS
COMM: COMMUNICATION(S)
CORR: CORRIDOR
CPT: CARPET
R: RISER
RA: REGISTERED ARCHITECT
RAD: RADIUS
RBT: RABBET
RCP: REFLECTED CEILING PLAN
REBAR: REINFORCING BAR
REF: REFRIGERATOR
REINF: REINFORCEMENT, OR REINFORCE
REQD: REQUIRED
REV: REVISION
RM: ROOM
RO: ROUGH OPENING
S: SOUTH
S4S: SURFACED 4 SIDES
S&S: STAINED & SEALED
S&V: STAIN & VARNISH
SAN: SANITARY
SF: SQUARE FOOT
SHT: SHEET
SIM: SIMILAR
SPEC: SPECIFICATION(S)
SPK: SPEAKER
SQ: SQUARE
ST: STAINLESS
STC: SOUND TRANSMISSION CLASS
STD: STANDARD
STL: STEEL
STRUCT: STRUCTURAL
SUSP: SUSPENDED
SYS: SYSTEM
T: TREAD
TBD: TO BE DETERMINED
T&G: TONGUE & GROOVE
TEL: TELEPHONE
TD: TRENCH DRAIN
THK: THICK, THICKNESS
THRU: THROUGH
TLT: TOILET
T.O. TOP OF
TRAV: TRAVERTINE
TSL: TOP OF SLAB
TST: TOP OF STEEL
TV: TELEVISION
TYP: TYPICAL
UC: UNDER CABINET
UL: UNDERWRITERS LABORATORIES
UNO: UNLESS NOTED OTHERWISE
UR: URINAL
VB: VINYL BASE
VCT: VINYL COMPOSITION TILE
VERT: VERTICAL
VIF: VERIFY IN FIELD
VNR: VENEER
VTR: VENT THROUGH ROOF
W: WIDTH, WEST
W/: WITH
WC: WATERCLOSET
WD: WOOD
WH: WATER HEATER
WIN: WINDOW
W/O: WITHOUT
WP: WORK POINT
WT: WEIGHT
WWF: WELDED WIRE FABRIC
1. CORRELATION AND INTENT OF THE CONTRACT DOCUMENTS: THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK BY THE CONTRACTOR. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL; PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE EXTENT CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABLY INFERABLE FROM THEM AS BEING NECESSARY TO PRODUCE THE INDICATED RESULTS.
2. THE CONTRACTOR SHALL EXAMINE ALL DRAWINGS LISTED IN THE DRAWING INDEX BEFORE BEGINNING THE WORK. ANY DOUBT AS TO THE MEANING OR SCOPE OF THE DRAWINGS AND SPECIFICATIONS, OR ANY OTHER PORTION OF THE CONTRACT, MAY BE CLARIFIED BY SUBMITTING A REQUEST IN WRITING FOR INTERPRETATION TO THE ARCHITECT WHO WILL PROVIDE CLARIFICATION. ABSENCE OF SUCH REQUEST FOR CLARIFICATION WILL IMPLY A FULL
UNDERSTANDING OF THE INTENT OF THE DRAWINGS AND SPECIFICATIONS.
3. IN THE CASE OF CONFLICTING DATA CONTAINED WITHIN THE CONTRACT DOCUMENTS, CONTRACTOR MAY ISSUE AN RFI FOR CLARIFICATION. IN THE ABSENCE OF RFI OR OTHER CLARIFICATION, CONTRACTOR IS TO ASSUME THE
MOST STRINGENT (BEST QUALITY AND HIGHEST QUANTITY) APPROACH IS INTENDED.
4. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. LARGER SCALE DRAWINGS TO GOVERN OVER SMALLER SCALE DRAWINGS.
5. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR IS RESPONSIBLE TO GET CLARIFICATION AND DIRECTION FROM ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.
6. ALL WORK TO COMPLY WITH APPLICABLE CODES. THE CONTRACTOR MUST COMPLY WITH THE RULES AND REGULATIONS OF AGENCIES HAVING JURISDICTION AND TO CONFORM TO ALL CITY, COUNTY, STATE AND FEDERAL
CONSTRUCTION, SAFETY AND SANITARY LAWS, CODES, STATUTES AND ORDINANCES.
7. ALL FEES, TAXES, PERMITS, APPLICATIONS AND CERTIFICATES OF INSPECTION AND THE FILING OF ALL WORK WITH GOVERNMENTAL AGENCIES TO BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR TO OBTAIN ALL
PERMITS AND APPROVALS PRIOR TO COMMENCEMENT OF THE WORK.
8. THE CONTRACTOR TO COMPLY WITH THE RULES AND REGULATIONS OF THE BUILDING OWNER AND MANAGER CONCERNING HOURS OF AVAILABILITY OF ELEVATOR FOR MATERIAL TRANSPORT AND DELIVERY AS WELL AS THE
MANNER OF HANDLING MATERIALS, EQUIPMENT AND DEBRIS.
9. ALL WORK SHALL BE PERFORMED BY SKILLED AND QUALIFIED WORKMEN IN ACCORDANCE WITH THE BEST PRACTICES OF THE TRADES INVOLVED AND IN COMPLIANCE WITH BUILDING REGULATIONS AND/OR GOVERNMENT LAWS, STATUTES OR ORDINANCES CONCERNING THE USE OF UNION LABOR.
10. CONTRACTOR AND SUB-CONTRACTORS TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DOCUMENTS AND MUST NOTIFY ARCHITECT OF ANY DISCREPANCIES, OMISSIONS AND/OR CONFLICTS PRIOR TO
PROCEEDING WITH THE WORK.
11. EACH TRADE WILL BE EXPECTED TO PROCEED IN A FASHION THAT WILL NOT DELAY OTHER TRADES.
12. THE CONTRACTOR IS RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER THEIR JURISDICTION.
13. ALL MATERIALS TO BE NEW, UNUSED AND OF THE HIGHEST QUALITY IN EVERY RESPECT, UNLESS OTHERWISE NOTED. MANUFACTURED MATERIALS AND EQUIPMENT TO BE STORED AND INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN RECOMMENDATIONS AND INSTRUCTIONS.
14. THERE WILL BE NO SUBSTITUTIONS OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERMS "EQUIVALENT TO" OR "APPROVED EQUAL" ARE USED, THE ARCHITECT TO DETERMINE EQUIVALENCE BASED ON
INFORMATION SUBMITTED BY THE CONTRACTOR.
15. ALL WORK AND MATERIALS TO BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR AFTER APPROVAL OF FINAL PAYMENT.
16. THE CONTRACTOR IS RESPONSIBLE FOR CUTTING AND PATCHING REQUIRED FOR HIS WORK UNLESS OTHERWISE NOTED.
17. THE CONTRACTOR TO, AT ALL TIMES, KEEP THE PREMISES FREE OF ACCUMULATION OF WASTE MATERIALS OR RUBBISH; PREMISES TO BE SWEPT CLEAN DAILY.
18. THE CONTRACTOR TO PROVIDE FINAL CLEANING OF ALL AREAS OF WORK INCLUDING THE CONSTRUCTION ACCESS ROUTE. FINAL CLEANING TO INCLUDE WINDOWS AND CEILINGS.
19. ALL INSTALLED PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT TO OPERATE QUIETLY AND BE FREE OF VIBRATION.
20. ALL FINISHES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS FOR THE TYPE OF MATERIAL AND INSTALLATION SPECIFIED.
21. PATCH ALL AREAS WHERE THE FLOOR IS NOT LEVEL OR TRUE PRIOR TO THE INSTALLATION OF SPECIFIED FLOOR FINISH(ES).
22. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE BLOCKING FOR WALL SUPPORTED ELEMENTS INCLUDING MILLWORK, EQUIPMENT, FIXTURES AND FURNITURE. CONTRACTOR TO VERIFY EXTENT AND COORDINATE
WITH APPROPRIATE SUBCONTRACTORS.
23. DRYWALL CONTRACTOR TO CLOSELY COORDINATE HIS WORK WITH THAT OF OTHER TRADES. WHERE DRYWALL IS IN CONFLICT WITH DUCTWORK, PLUMBING LINES, ETC. THIS CONTRACTOR TO PROVIDE ALL NECESSARY BRIDGING AND BRACING REQUIRED TO SECURE DRYWALL AND TO MAINTAIN FIRE OR SOUND RATING WHERE REQUIRED.
24. EXTEND ALL FIRE RATED PARTITIONS TO STRUCTURE; FILL ALL VOIDS WITH FIRE SAFING MATERIAL OR FIRE-RATED CAULK, CONTINUOUS AS REQUIRED BY CODE.
25. CONTRACTOR IS RESPONSIBLE FOR FIRESTOPPING ALL NEW AND EXISTING FIRE RATED PARTITIONS AND ALL PENETRATION THROUGH RATED AREAS INCLUDING SLABS. SEAL TO MAINTAIN PROPER RATING.
26. PROVIDE ALL NECESSARY CUT-OUTS FOR THE INSTALLATION OF ELECTRICAL AND VOICE/DATA OUTLETS, THERMOSTATS, SWITCHES AND OTHER DEVICES.
27. WHERE DUCT OR PART OF DUCT IS RUNNING PARALLEL OVER FIRE RATED PARTITION, EXTEND RATED PARTITION AROUND DUCT TO EFFECT COMPLETE MAINTENANCE OF FIRE-RATING.
TO BE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND CHAPTER 633, FLORIDA STATUTES.
S103 WELL HOUSE FRAMING PLANS
S201 ROOF FRAMING PLAN
S401 FOUNDATION SECTIONS & DETAILS
S402 FOUNDATION SECTIONS & DETAILS
S403 FOUNDATION SECTIONS & DETAILS
S404 FOUNDATION SECTIONS & DETAILS
S501 SHEET REMOVED
S502 SHEET REMOVED
S601 FRAMING SECTIONS & DETAILS
S602 FRAMING SECTIONS & DETAILS
S603 FRAMING SECTIONS & DETAILS
MECHANICAL
M101 SHEET REMOVED
M101A HVAC FLOOR PLAN - AREA A
M101B HVAC FLOOR PLAN - AREA B
M101C HVAC FLOOR PLAN - AREA C
M102 HVAC ROOF PLAN
M201 HVAC SCHEDULE
M202 HVAC SCHEDULE
M203 HVAC DETAILS
M204 HVAC DETAILS
M206 REFRIGERANT CALCULATIONS
M301 HVAC - KITCHEN HOOD DRAWINGS
M302 HVAC - KITCHEN HOOD DRAWINGS
M303 HVAC - KITCHEN HOOD DRAWINGS
M304 HVAC - KITCHEN HOOD DRAWINGS
M305 HVAC - KITCHEN HOOD DRAWINGS
M306 HVAC - KITCHEN HOOD DRAWINGS
M307 HVAC - KITCHEN HOOD DRAWINGS
PLUMBING
P101 PLUMBING FLOOR PLAN
P102 PLUMBING ROOF PLAN
P201 ENLARGED PLUMBING PLANS
P301 PLUMBING RISER DIAGRAMS
P302 PLUMBING RISER DIAGRAMS
P303 PLUMBING RISER DIAGRAMS
P401 LEGEND, SCHEDULES & MISC. DETAILS
P402 MISC. DETAILS
FIRE PROTECTION
FP101 FIRE PROTECTION "A TO M" PLAN
ELECTRICAL
E001 PHOTOMETRIC SITE PLAN
E100 ELECTRICAL SITE PLAN
E101 LIGHTING PLAN
E102 POWER/COMM PLAN
E103 FIRE ALARM PLAN
E104 LIGHTINING PROTECTION SYSTEM
E105 POWER RISER & PANEL SCHEDULES
E106 PANEL SCHEDULES
E107 PANEL SCHEDULES
E108 FIRE ALARM RISER & A-O CRITERIA
E109 ELECTRICAL DETAILS
E110 ELECTRICAL DETAILS
TECHNOLOGY
T101 COMM SYSTEMS PLAN
T102 BDA SYSTEM PLAN
T201 COMM SYS DETAILS & NOTES
T202 COMM SYS DETAILS & NOTES
EXHIBIT
1 PURVIS SYSTEMS - FSAS SUMMARY PAGE
2 PURVIS SYSTEMS - FSAS CLAY COUNTY
STATION 24
3 MEETING ROOM - A/V SYSTEM
NOTES:
1) PURVIS SYSTEM AND AV SYSTEM TO BE INCLUDED IN BID IN ITS ENTIRETY (DEVICES, CABLING, CONDUIT, INSTALLATION, COMMISSIONING, ETC.). EXHIBIT DRAWINGS ARE FOR REFERENCE AND NOT PRODUCED BY DASHER HURST ARCHITECTS OR ASSOCIATED ENGINEERS. DASHER HURST ARCHITECTS AND ASSOCIATED
ENGINEERS ARE NOT RESPONSIBLE FOR EXHIBIT DRAWINGS.
2) PURVIS SYSTEM AND AV SYSTEM DRAWINGS ARE NOT INCLUDED IN PERMIT DOCUMENTS.
3) SEE CIVIL SET FOR CIVIL, LANDSCAPE & IRRIGATION DRAWINGS.
BID NOTES & ALTERNATIVES
A) NOTE REMOVED
B) NOTE REMOVED
C) NOTE REMOVED
REVISIONS
# DATE DESCRIPTION
1 11/03/2023 Permit Rev 1
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
5 01/02/2026 90% V2 IRC REVIEW
6 02/17/2026 Add #1
Dra in F ield
Conc. B lock
Pumphouse w /W ell
Garage
.3
48.0'
48.0'
.2
Septic T ank
Concrete
Flag Pole
Modular Building
.6
70.3'
70.3'
.6
Asp hal t D riv e p p p pp p p p p p p x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
Gravel Parking Area x x x x x x x x x x
Concrete
Concrete
Concrete
Concrete x x x x x x x x x x x x
6.95 acre s±
D ir t D ri v e
D ir t D ri v e
D ir t D ri v e p p p p p p p p p p p p p p p
E d g e o f P a v e m e n t x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
"X
E C
M P
S 43°18'11" E
355.75'
Concrete
Prescriptive Right-of-Way as per Road Map Book 1, page 66
A s p h a l t
N
°2
'0
E
.7
BENCH M
ARK
PK nail i n P ower P ole
Elev. = 61.43
1/2" I ro n R od, L
B 7055
4"x 4" C onc. M
on. C lary
S 57°33'42" E (FM)
H Y
D
. 0
. 0
. 0
63.0
. 0
.0
.0 5
.0
.0
50.0
52.0
54.0
.0
.0
.0
.0
.0
.0
.0
.0
B O
T
.0
B O
T .0
BOT. 48.0
TOB 52.5
EXISTING LIVING
QUARTERS
FUTURE
DEVELOPMENT
FUTURE
(3.06 ACRES)
R A
M P
D O
W N
RAMP
DOWN
RAMP
DOW
N
RAMP
DOWN
3' CT
6' CT
6' CT
3' CT
3' CT
3' CT
3' CT
' C
T
3' CT
3' CT
6' CT
3' CT
3' CT
3' CT
D O
N O
T E
N T
E R
D O
N O
T E
N T
E R
STORMWATER
DETENTION
DRIVEWAY TO FUTURE
DEVELOPMENT
EXISTING LIVING
QUARTERS
SITE EXIT
SWEAT ROAD
C O
U N
T Y
R O
A D
SITE
ENTRANCE
EXISTING WELL
LOCATION
EXISTING SEPTIC
LOCATION
EXISTING
POWER POLE
FUTURE BUNK
ROOM
EXPANSION
FUTURE
APPARATUS BAY
EXPANSION
DUMPSTER
GENERATOR
XFRMR
FENCE
F E
N C
E
F
IR
E F
IG
H
T E
R P
A R
K
IN
G s p a c e s
F E
N C
E
SLIDING
GATE
16633 SF +/-
FIRE STATION
(TOTAL)
V
IS
IT
O
R P
A R
K
IN
G s p a c e s
4 APPARATUS
BAYS X
(TWO DEEP)
SEPTIC FIELD
(CONSTRUCT
FOLLOWING THE
DEMOLITION OF
EXISTING APPARATUS
GARAGE)
CONCRETE
APRON - SEE CIVIL
WELL HOUSE
FILL STATION
(FIRE HOSE
BIBB) - SEE CIVIL
A504
A504
MONUMENT
SIGN A504
FLAG POLE
BIKE RACK
CONCRETE
APRON - SEE CIVIL
FIRE HYDRANT -
SEE CIVIL
AERATION TANKS
FOR POTABLE
WATER WELL
FIRE PUMP WELL
55' - 0"
144' - 8" 74' - 7 5/8"
MAN GATE W/ CARD
READER. PROVIDE
SECURITY SCREENING
AROUND DOOR HDWR
POTABLE WATER
WELLS
SEE CIVIL DWGS
FOR DETAILS
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
ARCH SITE
PLAN
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A100
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
S
N
EW
PROJECT NORTH
1" = 40'-0"
ARCHITECTURAL SITE PLAN-COLOR
REVISIONS
# DATE DESCRIPTION
1 11/03/2023 Permit Rev 1
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
6 02/17/2026 Add #1
A201
MEETING
W A
TC
H
LOBBY
CORR
CORR
ELEC
QUIET RM
112 OFFICE
IT
K
IT
C H
E N
DINING
SHOWER RM
V E S
TI
B U
LE
5 CAPT SUITE
MAINT
STOR
WOMEN
LA
U
N D
R Y
CORR
UTIL
UTIL
FITNESS
CORR
DECON
APP BAY
LO
C
K E R
S
UTIL
CAPT OFF
CAPT RR
BUNK1
BUNK3
BUNK4
BUNK5
BUNK6
BUNK8
BUNK9
BUNK10
W/C
BUNK 12
BUNK 13
CORR
LO
C
K E R
LO
C
K E R
LO
C
K E R
LO
C
K E R
LOCKER
HAND & BOOT
WASHING
STATION
SECTIONAL DOOR SECTIONAL DOOR SECTIONAL DOOR
SECTIONAL DOOR
HOSPITALITY
STATION
T R
E N
C H
D R
A
IN
T
Y P
C E
N T
E R
O N
D O
O R
T H
IS
C
O N
F
IG
U R
A T
IO
N
A L L O
W S
F O
R F
U T
U R
E G
R O
W T
H O
F A
P P
A R
A T
U S
B A
Y S
T O
T H
E E
A S
T
ICE
P
A N
T R
IE
S
36" GAS
RANGE
T V
T V
LAWN CARE, ETC
WALK OFF MAT
DRYEXTRACT
PORTABLE PPE LOCKERS
(37 SHOWN)
WALK OFF MAT
A/C
A/C A/C
A/C
DESK
TABLE
WALK OFF MAT
C O
F F
E E
12P
B U
IL
T
I N
C R
E D
E N
Z A
GAS
H2O
A/C
D O
U B
L E
T
IE
R -C
L O
T H
IN
G
L
O C
K E
R
SB
E N
C H
B E
N C
H
LOCKERS
LINENS
CORR
COVERED ENTRY
CLOSET
BUNK2
COVERED PATIO
LO
C
K E R
A301
A301
A302
A302
A301
A301
P P
E S
TO
R
24"
A302
A302
A301
A301
A302
A302
A302
A302
A301
A301
2 3 4
A312
MECH
BUNK7
LOCKER
BUNK11
LO
C
K E R
SHWR1
(ADA)
SHWR2
SHWR3
SHWR4
IS
L A
N D
R E
F R
E F
S
IN
K
A401
102A
103A 103B
A
130A
120 121
C
164B
113 112 111
105 106
170D170C170B
170K 170J170L
130B
170F
170G
170H
123B
B
161B
107B 164A
139 145
143141
170E
A401
A401
A401
A401
A401
A401
CLOS
123A
158B
A701 1
A701
A7014 9 A501
101B
CHARGING
STATION
WORKSTATION &
CHARGING SHELF
A704 12
A703 13
A703
A703
SA4A
S A
A
SA4
S A
A
S A
A
SA4A
SA4A
S A
A
SA4A
SA4A
SA4A
SA4A
F Z
A
SA4A
SA4A
SA4A
SA4A
SA4
S A
S A
SA4
SA4
S A
SA4
SA4A
SA4
SA4A
S A
A
SA4A
SA4A
SA4
S A
A
SA4A
S G
.5
A
SG4.5A
SG4.5A
SG4.5A
SA4A
SG4.5A
SG4.5A
SG4.5A
SG4.5A
SG4.5A
SG4.5A
SG4.5A
SG4.5A
SG4.5A
SG4.5A
SG4.5ASG4.5A
SG4.5A
SA4SA4
SA4ASG4.5A
SA4
M8
SA4
SA4
SA4A
SA4
SA6A
SA4
SA4A
102B
W
D
H2O
W A
S H
T
U B
SA4A
MM8
M8
M M
M
M A
M8FZ2A
F Z
A
M A
F Z
A
F Z
A
F2
F2
M M
M
M
FZ2A
F2
FZ2A
FZ2A
MM8
MA81
MM8
MM8
F Z
A
PAINTED STL
BOLLARD (TYP)
PAINTED STL
BOLLARD (TYP)
M M
M
SA4
S A
A
PAINTED STL
BOLLARD (TYP)
PAINTED STL
BOLLARD (TYP)
COLUMN
COLUMN
PRINTER
L
IN
E N
S
MEN
WOMEN
A6039
DAY ROOM
D D D D
F
F
D
D
D
A
D
D
D
E
D
D
B
C
E
E
E
E
E
E E
E
E
E
G
E
I
H
170P
A
A
A203
A203
A203
A203
A203
A203
SA4
SG4.5A SG4.5A
ADJUSTABLE SHELVES -
SEE TYP DTL
SF4
A804
CASCADE SYSTEM. BY OWNER
SCBA SYSTEM: BAUER COMPRESSOR.
BY OWNER. COOR W/ VENDER
SCBA SYSTEM: FILL STATION. BY
OWNER. COOR W/ VENDER
SS WASH SINK
GEAR DRYER
A/V EQUIP
NOOK
APP11
APP10
SECTIONAL DOOR
SECTIONAL DOORSECTIONAL DOORSECTIONAL DOOR
ROOF ACCESS
LADDER
A501
MEDICAL
A704
A7048 7
SA6A
SF4
BOTTLE FILL
DS DS
DS
DS DS
DS
DS
DS
DS
DSDS
DS
DS
DSDS
DS
DS
DS
DS
COLUMNS /
DOWNSPOUTS
FOR ALUM COVER
DS
FZ2AFZ2
T V
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
FLOOR PLAN
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A101
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
S
N
EW
PROJECT NORTH
1/8" = 1'-0"
FLOOR PLAN
REVISIONS
# DATE DESCRIPTION
1 11/03/2023 Permit Rev 1
2 12/11/2023 Permit Rev 2
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
6 02/17/2026 Add #1
6'
7'
/4
6'
/8
7'
/8
5'
5'
8'
2' - 0" 4' - 4" 4' - 0" 4' - 4" 2' - 0"
24"
3' - 4" 4' - 0" 6' - 0" 10' - 0"
3' - 4"
3' - 10 1/4" 14' - 9 3/4" 2' - 6 1/4" 14' - 9 3/4" 2' - 6 1/4" 14' - 9 3/4" 4' - 8"1' - 2 1/4" 14' - 9 3/4" 5' - 4"
10' - 8" 3' - 4" 2' - 8" 4' - 8" 14' - 0" 17' - 4" 17' - 4" 4' - 8" 16' - 0" 5' - 4"
1' - 4"
2' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8"
38' - 8" 10' - 0"
9' - 0" 20' - 8" 9' - 0"
6'
2'
5'
2'
5'
2'
4'
4'
2'
5'
2'
5'
2'
9'
2'
2'
1'
2'
3'
38' - 8" 26' - 8"
17' - 0" 4' - 8" 17' - 0" 10' - 0" 16' - 8"
4'
2'
1'
2'
8'
2'
1'
2'
8'
2'
1'
2'
4'
2'
4'
58' - 0" 21' - 4"
6'
3'
1' - 4"
6'
3'
16' - 8" 58' - 0" 21' - 4"
4'
/4
0"
8'
/8
8" 8"
4'
4'
8" 8"
4'
4'
8" 8"
1'
5' - 5 3/8" 5' - 6"
9' - 10 1/8" +/- 9' - 9 5/8" +/-
2'
4'
2'
4'
2'
1'
2'
2'
1'
2'
3'
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
A L
IG
N
A L
IG
N
A L
IG
N
O P
E N
IN
G
A L
IG
N
O P
E N
IN
G
ALIGN
2'
6'
4'
6'
3'
0"
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
2' - 1" 3 5/8"
8' - 6" 9' - 0 1/4" 8' - 9 5/8"
1/
2"
/4
3'
/8
ALIGN
ALIGN
A L
IG
N
2 1/2"
/8
ALIGN
1'
/2
2' - 3 3/8" 2' - 5 3/4"
A L
IG
N
2'
6'
1'
6'
2'
3'
8"
1'
3'
7'
ALIGN
1'
1'
3'
4"
2'
8'
3'
3'
4'
/4
7'
4"
3/ 8"
2'
3/ 4"
/2
/8
A L
IG
N
2' - 1"
3' - 4" 4' - 3 7/8"
2"
A L
IG
N
2 1/2"
8' - 1 3/4"
ALIGN
ALIGN
ALIGN
2' - 1 3/8"
ALIGN
ALIGN
ALIGN
8' - 6 3/4" 8' - 10" 9' - 9" 8' - 0 5/8"
8' - 7 5/8"
4'
3'
3'
3/
4"
3'
3'
3'
4"
1' - 4"
12' - 8"
2'
3' - 4" 6' - 5" 2' - 11"
2 1/2"
2 1/2"
1/
2"
ALIGN
7' - 0"
1/
2"
1/
2"
7' - 7 1/4" 7' - 9 5/8" 6' - 0 3/4" 5' - 8 1/8" 2"
10"
" 27
0'-0"
- 0'-1 1/2" - 0'-1 1/2" - 0'-1 1/2" - 0'-1 1/2"
- 0'-1 1/2" - 0'-1 1/2" - 0'-1 1/2" - 0'-1 1/2"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0" 0'-0" 0'-0" 0'-0"
- 0'-1 1/2"
SEE
DTL
SEE
DTL
SEE
DTL
SEE
DTL
S E
E D
T L
ADA
ADA
- 0'-1 1/2"
SEE
DTL
A102
5'
/4
3'
0"
5' - 6"
1' - 4"
1'
ALIGNALIGN
3' - 1"
4 1/4"
1/
8" 3'
3'
/8
3'
7/
8"
3'
7/
8"
3'
7/
8"
3'
3' - 1"
3' - 1"
3' - 1"
4 7/8"
3' - 1"
4 7/8"
3'
5/
8"
3' - 0 1/2" 8' - 3 1/4"
NOTE: CONTRACTOR
RESPONSIBLE FOR
VERIFYING LOCATIONS /
SIZES OF SHOWER
RECESSES
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
FLOOR
PLAN- DIMS
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A102
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
S
N
EW
PROJECT NORTH
1/8" = 1'-0"
FLOOR PLAN-DIMS
1/8" = 1'-0"
PARTIAL PLAN -DIMS SHOWER SLABS
REVISIONS
# DATE DESCRIPTION
2 12/11/2023 Permit Rev 2
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
6 02/17/2026 Add #1
F
B
W
MEETING
CPT-1
PT- 1/3
VB-2
F
B
W
WATCH
PC-1
PT- 1
VB-1
F
B
W
LOBBY
WM-1
PT-1
VB-1
F
B
W
CORR
PCT-1
PT-1/WT-1
PTB-1
F
B
W
CORR
PC-1/WM-1
PT-1
VB-1
F
B
W
ELEC
CONC-1
PT-1
VB-1
F
B
W
QUIET RM
CPT-1
PT-1
VB-1
F
B
W
OFFICE
CPT-1
PT-1
VB-1
F
B
W
IT
CONC-1
PT- 1
VB-1
F
B
W
KITCHEN
PC-1
PT-1/3
VB-1
F
B
W
DINING
PC-1
PT-1
VB-1
F
B
W
SHOWER RM
PCT-1
PT-5/WT-1
PTB-1
F
B
W
VESTIBULE
PC-1
PT- 1
VB-1
F
B
W
CAPT SUITE
PC-1
PT-1
VB-1
F
B
W
MAINT
CONC-1
PT- 1
VB-1
F
B
W
STOR
CONC-1
PT- 1
VB-1
F
B
W
MEDICAL
CONC-1
PT-5
VB-1
F
B
W
WOMEN
PCT-1
PT-5/WT-1
PTB-1
F
B
W
LAUNDRY
PC-1
PT-5/FRP
VB-1
F
B
W
CORR
PC-1/WM-1
PT-1
VB-1
F
B
W
UTIL
CONC-1
PT-1
VB-1
F
B
W
UTIL
CONC-1
PT-1
VB-1
F
B
W
FITNESS
RF-1
PT-1
VB-2
F
B
W
CORR
WM-1
PT-1
VB-1
F
B
W
DECON
EP-1
PT-5
EPB-1
F
B
W
APP BAY
EP-1
PT-5
EPB-1
F
B
W
LOCKERS
PCT-1
PT-1
PTB-1
F
B
W
UTIL
PC-1
PT-1/FRP
VB-1
F
B
W
CAPT OFF
PC-1
PT- 1
VB-1
F
B
W
CAPT RR
PCT-1
PT-5/WT-1
VB-1
F
B
W
BUNK1
PC-1
PT- 1
VB-1
F
B
W
BUNK3
PC-1
PT- 1
VB-1
F
B
W
BUNK4
PC-1
PT- 1
VB-1
F
B
W
BUNK5
PC-1
PT- 1
VB-1
F
B
W
BUNK6
PC-1
PT- 1
VB-1
F
B
W
BUNK8
PC-1
PT- 1
VB-1
F
B
W
BUNK9
PC-1
PT- 1
VB-1
F
B
W
BUNK10
PC-1
PT- 1
VB-1
F
B
W
W/C
PCT-1
PT-5/WT-2
PTB-1
F
B
W
BUNK 12
PC-1
PT- 1
VB-1
F
B
W
BUNK 13
PC-1
PT- 1
VB-1
F
B
W
CORR
PC-1
PT- 1
VB-1
F
B
W
LOCKER
PC-1
PT- 1
VB-1
F
B
W
LOCKER
PC-1
PT- 1
VB-1
F
B
W
LOCKER
PC-1
PT- 1
VB-1
F
B
W
LOCKER
PC-1
PT- 1
VB-1
F
B
W
LOCKER
PC-1
PT- 1
VB-1
F
B
W
CORR
PC-1
PT-1
VB-1
COVERED ENTRY
F
B
W
CLOSET
CPT-1
PT- 1
VB-2
F
B
W
BUNK2
PC-1
PT- 1
VB-1
COVERED PATIO
F
B
W
LOCKER
PC-1
PT- 1
VB-1
F
B
W
PPE STOR
EP-1
PT-5
EPB-1
F
B
W
BUNK11
PC-1
PT- 1
VB-1
F
B
W
LOCKER
PC-1
PT- 1
VB-1
F
B
W
BUNK7
PC-1
PT- 1
VB-1
F
B
W
LOCKER
PC-1
PT- 1
VB-1
WM-1
WM-1
F
B
W
MEN
PCT-1
PT-5/WT-2
PTB-1
F
B
W
WOMEN
PCT-1
PT-5/WT-2
PTB-1
TS-4
TS-5
TS-1
TS-5 THRESH
TS-1
TS-5
THRESH
TS-4
TS-4
TS-1TS-4
THRESH
D R
A
IN
(T Y
P
TS-4
STEEL COLUMN
PAINTED PT-2 -
TYP.
BOLLARD PAINTED
PT-10 - TYP.
BOLLARD PAINTED
PT-10 - TYP.
F
B
W
DAY ROOM
PC-1
PT-1/2/3
VB-1
THRESH
THRESH
THRESH
THRESH
THRESH
THRESH
THRESH
THRESH
THRESH
THRESH
THRESH
THRESH
C.J.
C.J.
C.J.
C.J.
C.J.
C.J.
C.J.
C .J
C .J
C.J.
C.J.
C.J.
C.J.
C .J
C .J
C .J
C .J
C .J
SEE INT ELEVS
PT-3
PT-3
P T-
P T-
P T2
TYP
5' - 0"
TYP
5' - 0"
TYP
EQ
TYP
EQ 6" STRIPING AT DOORS
(TYP). 5 FT FROM
CENTER OF DOOR. 50 FT
LONG. EP-1 SECONDARY
COLOR TO BE CHOSE BY
ARCH.
P T2
F
B
W
MECH
CONC-1
PT- 1
VB-1
THRESH
E Q
E Q
30" ARIAL BLACK LANE
MARKINGS. EP-1
SECONDARY COLOR TO
BE CHOSEN BY ARCH.
STEEL COLUMN
PAINTED PT-2 -
TYP.
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
FLOOR PLAN
- FINISHES
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A103
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
S
N
EW
PROJECT NORTH
1/8" = 1'-0"
FLOOR PLAN-FINISHES
REVISIONS
# DATE DESCRIPTION
2 12/11/2023 Permit Rev 2
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
5 01/02/2026 90% V2 IRC REVIEW
A201
STANDING SEAM
METAL ROOF (TYP)
RF-1
R
ID
E
R
ID
RIDGE
RIDGE
R
ID
VALLEY
VALLEY
A301
A301
A302
A302
A301
A301
A301
A301
A302
A302
A302
A302
A301
A301
A312
VALL
EY
VALLEY
R
ID
RF-2
TPO LOW SLOPE
ROOF
S L O
P E
/4
(T Y
P
L
W
L O
P E
R O
O F
SCUPPER
BELOW -
SEE ELEV
SCUPPER
BELOW -
SEE ELEV
DS
DS
DS
DS
DS
DS
DS
DS
DSDS
DS
4" / 1'-0" 2" / 1'-0"
4" / 1'-0"
4" / 1'-0"
DS
DS
DS
3" / 1'-0"10" / 1'-0"10" / 1'-0"
3" / 1'-0"10" / 1'-0"10" / 1'-0"
3" / 1'-0"
3" / 1'-0"
3" / 1'-0"
STANDING SEAM
METAL ROOF (TYP)
RF-1
PRE-ENGINEERED
ALUM COVER -
DRAINAGE OCCURS
WITHIN COLUMNS
FOR COVER
PRE-ENGINEERED
ALUM COVER
DS
DS
A314
A203
A203
A203
A203
A203
A203
ROOF ACCESS
HATCH & LADDER
DOWNSPOUT FROM
MAIN ROOF PENETRATES
THROUGH ALUM COVER -
SEE ELEV
RIDGE
GENERAL NOTES:
UNLESS OTHERWISE NOTED
• ALL GUTTERS TO BE 6" X 6" SQUARE
• ALL DOWNSPOUTS TO BE 5" X 5" SQUARE
• ALL FASCIA, GUTTERS, AND DS TO MATCH FINISH OF
STANDING SEAM ROOF
• DOWNSPOUTS AT PRE-ENGINEERED ALUM COVERS
TO BE PROVIDED BY PRE-ENGINEERED MNFR TO
MATCH FINISH OF ALUM COVER
• PROVIDE TAPERED INSULATION ON LOW SLOPE
ROOF TO SLOPE ROOFING @ 1/4" PER FOOT
G U
T T
E R
G U
T T
E R
G U
T T
E R
G U
T T
E R
G U
T T
E R
G U
T T
E R
G U
T T
E R
G U
T T
E R
G U
T T
E R
G U
T T
E R
G U
T T
E
R GUTTER
G U
T T
E R
GUTTERG
U
T T
E R
G U
T T
E R
DOWNSPOUT FROM
MAIN ROOF
PENETRATES
THROUGH ALUM
COVER - SEE ELEV
G U
T T
E R
PRE-ENGINEERED
ALUM COVER
DOWNSPOUT
PROVIDE TWO
DRAINAGE SCUPPERS IN
BTM OF GUTTER OF
PRE-ENGINEERED ALUM
COVER
PROVIDE TPO
WALKWAY
PROTECTION
ALONG ROOF &
AROUND
EQUPMENT
NOTES ADDED TO SHEET TO CLARIFY
ROOF DRAINAGE, GUTTER & DS SIZES, ETC
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
ROOF PLAN
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A104
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
S
N
EW
PROJECT NORTH
1/8" = 1'-0"
ROOF PLAN
REVISIONS
# DATE DESCRIPTION
2 12/11/2023 Permit Rev 2
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
M
E
TI
N G
W A
TC
H
LOBBY
CORR
CORR
ELEC
QUIET RM
OFFICE
IT
KITCHEN
DINING
SHOWER RM
V E S
TI
B U
LE
C A
P T
S U
IT
E
MAINT
CLOSET
CORR
STOR
W O
M E N
LA
U
N D
R Y
CORR
UTIL
UTIL
FITNESS
CORR
DECON
APP BAY
LO
C
K E R
S
UTIL
BUNK8
BUNK9
BUNK10
LOCKER
LOCKER
W/C
BUNK 13
BUNK 12
BUNK1
BUNK2
LOCKER
BUNK3
BUNK4
BUNK6
BUNK5
LOCKER
LOCKER
C A
P T
O
FF
C A
P T
R R
LOCKER
A301
A301
A302
A302
A301
A301
A302
A302
A301
A301
A302
A302
A302
A302
A301
A301
A312
PPE STOR
CORR
E Q
E Q
3' - 6"
10' - 0"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2 8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
PT-6
GWB
8' - 4"
ACT-2
8' - 4"
PT-6
GWB
8'
4" A
C T-
8' - 4"
PT-6
GWB
8' - 4"
ACT-2
8' - 4"
PT-4
GWB
8' - 4"
PT-4
GWB
8' - 4"
ACT-2
8' - 4"
ACT-2
8'
4" A
C T-
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
PT-6
GWB
8' - 4"
PT-6
GWB
8' - 4"
PT-6
GWB
8' - 4"
PT-6
GWB
8' - 4"
ACT-2
8' - 8"
ACT-2
8' - 4"
PT-4
GWB
8' - 4"
PT-4
GWB
8' - 4"
PT-4
GWB
9' - 0"
ACT-2
8' - 4"
ACT-2
8' - 8"
PT-4
GWB
10' - 0"
PT-4
GWB
8' - 8"
PT-1
GWB
8' - 8"
ACT-2
8'
4" A
C T-
7' - 2"
PT-1
GWB
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
GWB
8' - 4"
PT-1
GWB
8' - 4"
ACT-2
8'
4" A
C T-
8' - 4"
ACT-2
8'
4" A
C T-
8'
4"
A C
T-
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8' - 4"
ACT-2
8'
4" A
C T-
16' - 8"
ACT-1
8' - 4"
ACT-2
8' - 4"
PT-3
GWB
10' - 0"
ACT-2
9' - 0"
PT-4
GWB
8' - 4"
ACT-2
WOMEN
MEN
BUNK7
BUNK11
LOCKER
LOCKER
8' - 4"
ACT-2
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
GWB CEILING - SLOPE ON
SCISSOR TRUSSES
SLOPE UPSLOPE UP3 1/2"
1/
2"
PENDANT FIXTURES
1/
2"
PRE-ENG ALUM
COVER
PRE-ENG
ALUM COVER
3' - 8"
2'
7' - 0"
GWB
8' - 4"
PT-6
GWB
8' - 4"
PT-6
GWB
8' - 8"
PT-1
GWB
8' - 8"
PT-1
GWB
RECESSED MOTORIZED
PROJECTOR SCREEN
GWB FLAT
CEILING SOFFITS
8' - 4"
PT-1
GWB
8' - 8"
PT-1
GWB
10' - 8"
GWB
8'
4" A
C T-
CEILING MOUNTED
PROJECTOR
METAL
SOFFIT
SAME AS
EAVE
A314
12' - 0"
4' - 2"
CENTER ON
ISLAND
1'
E Q
E Q
3'
3'
3'
OUTSIDE OF
CEILING SOFFIT
ABOVE (SF4)
(T Y
P
(T Y
P
CEILING MOUNTED
ELECTRICAL REEL -
SEE DTL
CEILING MOUNTED
ELECTRICAL REEL -
SEE DTL
CEILING MOUNTED
ELECTRICAL REEL -
SEE DTL
CEILING MOUNTED
ELECTRICAL REEL -
SEE DTL
A804
A804
6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"EQ EQ
Q
5' -6
E
Q
5/8" GWB ON 3-5/8"
METAL STUD SOFFIT
AROUND OPENING
16' - 8"
ACT-1
30 MIN FIRE & SMOKE RATED GWB CEILING
@ BOTTOM OF TRUSSES OVER BUNK
ROOMS & CAPTAINS SUITE - LIFE SAFETY
PLAN & SECTION
MEDICAL
MECH
7' - 0"
GWB
8' - 8"
PT-1
ACT-2
8' - 4"
PT-4
GWB
8' - 8"
PT-4
GWB
8' - 4"
PT-4
GWB
8' - 8"
PT-4
GWB
8' - 4"
PT-4
GWB
7' - 2"
PT-4
GWB
TYP @
LOCKERS
NO CEILING IN FITNESS ROOM.
CONTRACTOR TO PAINT EXPOSED
TRUSSES, FRAMING & DECKING -
PT6. CONTRACTOR RESPONSIBLE
FOR SEALING SPACE FROM THE
REST OF THE BUILDING. EXPOSED
CONDUIT & PIPING TO BE PAINTED
AS WELL
LED LINEAR LIGHTING -
SUSPENDED IN SURFACE
MOUNTED IN - SEE PLAN FOR
LENGTH
RETURN AIR GRILLE / EXHAUST FAN - SEE
MECH
RCP LEGEND
CEILING TAG:
2X4 LIGHT FIXTURE - SEE ELEC
2x2 LIGHT FIXTURE - SEE ELEC
RECESSED DOWNLIGHT (ROUND)
8'-0"
PT-1
ACT-1
HEIGHT
MATERIAL
FINISH (IF NOT PREFINISHED)
SEE ELECTRICAL FOR ALL LIGHT FIXTURES
SEE MECHANICAL FOR DUCTWORK AND RELATED DIFFUSERS, ETC
SUPPLY AIR GRILLE / EXHAUST FAN - SEE
MECH
RECESSED DOWNLIGHT (SQUARE)
1x4 SURF MTD LIGHT FIXT - SEE ELEC
WALL PACK LIGHT
CYLINDRICAL DOWNLIGHT SURFACE
MOUNTED
ACOUSTICAL TILE CEILING W/ HOLD DOWN
CLIPS
ACOUSTICAL TILE CEILING - SEE SCHEDULE
FOR TYPE
PAINTED GYPSUM BOARD CEILING OR
SOFFIT
ALUMINUM SOFFIT PANELS: PETERSON PAC-
CLAD - PAC-850
RECESSED CEILING SPEAKER
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
REFLECTED
CLNG PLAN
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A111
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
S
N
EW
PROJECT NORTH
1/8" = 1'-0"
REFLECTED CEILING PLAN
DRAWING REMOVED
REVISIONS
# DATE DESCRIPTION
1 11/03/2023 Permit Rev 1
2 12/11/2023 Permit Rev 2
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
6 02/17/2026 Add #1
TOP OF SLAB
0' - 0"
T/ MAS APP BAY
19' - 4"
T/ MAS L.Q.
10' - 8"
PREFAB METAL CANOPY
A
A301
A301
A301
A301
A302
A302
A302
A302
A312
RF-1
RF-3
CMU-3
STU-1
CMU-1
CMU-1A
RF-1
CMU-1
CMU-1A
E
RF-3
STU-1
B
CMU-1
CMU-1A
PREFAB METAL CANOPY W/
DOWNSPOUTS IN COLUMNS
SCREEN WALL IN FRONT
8'
IDENTIFICATION
SIGN & PLAQUE
DOWNSPOUT (TYP) -
SEE ROOF PLAN
7'
DDD D D D D D
E E E E E E E
101A
ADDRESS NUMBERING ON GLASS
MALTESE CROSS SIGNAGE ON GLASS W/ STANDOFFS
CJ CJ CJDOWNSPOUT (TYP) -
SEE ROOF PLAN
TYP
CONC
TYP
CONC
BDA ANTENNA. VERIFY LOCATION
BEFORE INSTALLATION
TOP OF SLAB
0' - 0"
T/ MAS APP BAY
19' - 4"
T/ MAS L.Q.
10' - 8"
CMU-1 CMU-1
A301
A301
A301
A301
A302
A302
A302
A302
A312
CMU-1A CMU-1A
MTL-1
CMU-2
156 157
170F
CMU-2
CMU-2A
MTL-1
CMU-2
CMU-2A
MTL-1
CMU-1
CMU-1A
CMU-1
CMU-1A
170G
CMU-1
CMU-1A
RF-1RF-1
CMU-1
CMU-1A
PE-1PE-1
DOWNSPOU
T (TYP) - SEE
ROOF PLAN
8'
2'
7'
102B
4"
1'-0"
E E
A314
CJ CJ
VEHICLE EXHAUST - CENTER ON
RECESS IN MASONRY - HOLD AS
HIGH AS POSSIBLE
EXTERIOR PRODUCT LEGEND
MAT'L DESCRIPTION
MNFR (BASIS OF
DESIGN)
ITEM / STYLE COLOR / FINISH SIZE / TYPE LOCATION REMARKS
FLORIDA
PRODUCT
APPROVAL #
CONTACTS
CONCRETE
CONC-1 PRECAST CONCRETE COPING TO MATCH CMU-3 EXT GABLE ENDS
CMU
CMU-1 INTEGRAL COLOR CMU OLDCASTLE’S ECHELON
MASONRY, MFD BY ADAMS
PRODUCTS CO IN
MORRISVILLE, NC
SPLIT FACE CMU 4302 (WHITE) NOMINAL 8"x16" SEE ELEVATIONS SEE PLAN FOR CMU THICKNESS. 8" TYPCAL.
12" THICK AT APP BAY EAST & WEST.
DOUBLE 8" AT APP BAY NORTH & SOUTH.
BOND BEAMS TO MATCH
Lisa Pelham, CSI CDT Commercials Sales Specification Representative Oldcastle Coastal Cell: 813.255.4737 lisa.pelham@oldcastle.com
CMU-1A POLISHED FACE CMU 4302-HP (WHITE)
CMU-2 SPLIT FACE CMU 4207 (GREY)
CMU-2A POLISHED FACE CMU 4207-HP (GREY)
CMU-3 GLAZED FACE CMU SPECTRA GLAZE 4" HIGH BLOCK RED I NOMINAL 4"X8"X16"
(STACK BOND)
BLDG ENTRANCE PROVIDE FINISHED RETURN AT CORNERS
GROUT
GRT-1 CONSISTENT COLORED MORTAR SPEC MIX SM750 WHITE AT GREY CMU
GRT-2 SM750 SILVERSTONE AT WHITE & RED CMU
DOORS
DR-1 HOLLOW METAL DOOR & FRAME -- SEE DOOR SCHEDULE IMPACT RATED
DR-2 OVERHEAD SECTIONAL DOOR OVERHEAD DOOR CORP 521 SERIES FULLY
GLAZED
CLEAR ANOD ALUM APPARATUS BAYS IMPACT RATED SYSTEM
DR-3 FOUR-FOLD DOOR DOOR ENGINEERING &
MANUFACTURING,KASOTA,
MN
FF701 SERIES GLAZED RAL 3001 SIGNAL RED 400 Cherry Street, Kasota, MN 56050, (800)-959-1352.
EXTERIOR PAINT
EP-1 EXTERIOR PAINT SHERWIN WILLIAMS RED (SEE INT FIN LEGEND
PT-10)
BOLLARDS
METALWORK
MTL-1 PREFINISHED ALUMINUM SIDING ATAS SNAP-ON BATTEN
PANEL (.040" THK)
SLATE GRAY 16" O.C. SEE ELEV
MTL-2 PREFINISHED ALUMINUM SIDING BONE WHITE
MTL-3 PREFIN ALUM FLASHING PAC CLAD 0.040" THICK MUSKET GRAY
MTL-4 PREFIN ALUM GUTTER & DOWNSPOUT
MTL-5 PREFIN ALUM COPING GAF 0.050" THICK MUSKET GRAY
ROOFING
RF-1 STANDING SEAM METAL
ROOFING W/ KYNAR FINSH
PAC CLAD SNAP CLAD (22 GAUGE) MUSKET GRAY 16" O.C. SEE ROOF PLAN
RF-2 TPO ROOFING SEE SPECS WHITE 20 YEAR NDL WARRANTY
RF-3 PREFABRICATED ALUMINUM CANOPY MAPES SUPER LUMIDECK FLAT
SOFFIT
KYNAR - COLOR MATCH SW
7069 IRON ORE
8" C-CHANNEL FASCIA
STUCCO
STU-1 CEMENT STUCCO 3-COAT CEMENT STUCCO W/ ELASTOMERIC PAINTED
FINISH
SW 7018 DOVETAIL / FINE
SAND
INTERIOR GABLE ENDS
ALUMINUM STOREFRONT
SF-1 KAWNEER IR501 W/ 1-9/16" GLASS CLEAR ANOD ALUM 2" X 5" IMPACT RATED SYSTEM
SEE GLAZING SCHEDULE
WOOD
WD-1 SYNTHETIC WOOD SIDING FIBERON CLADDING CONCORDIA GRAPHITE 1" X 5.5" SQUARE EDGES
MISCELLANEOUS
GENERAL PRODUCT REMARKS
SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION ON EACH PRODUCT.
BASIS OF DESIGN MANUFACTURER IS NOT MEANT TO PRECLUDE COMPETITIVE BIDDING. EQUIVALENT PRODUCTS FROM COMPETITIVE MANUFACTURERS WILL BE CONSIDERED PER THE REQUIREMENTS OF THE SPECIFICATIONS. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS FOR EACH
PRODUCT.
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
ELEVATIONS
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A201
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
1/8" = 1'-0"
WEST ELEVATION
1/8" = 1'-0"
EAST ELEVATION
REVISIONS
# DATE DESCRIPTION
1 11/03/2023 Permit Rev 1
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
TOP OF SLAB
0' - 0"
T/ MAS APP BAY
19' - 4"
T/ MAS APP BAY
19' - 4"
T/ MAS L.Q.
10' - 8"
T/ MAS L.Q.
10' - 8"
WD-1CMU-1
RF-1 4"
1'-0"
3"
1'-0"
OVERHEAD SECTIONAL DOORS
MTL-1
MTL-2
A302
A302
A302
A302
A301
A301
A301
A301
170H 170J 170K 170L
164A D D D D
CMU-1A
CMU-1
CMU-1A
CMU-2
CMU-2A
RF-3
CMU-2 CMU-1
CMU-2A
MTL-1
CMU-1A
MTL-1
PE-1
PREFAB METAL
CANOPY
SCREEN WALL
10"
1'-0"
DOOR POSITION INDICATOR LIGHT
STRIPS BOTH JAMBS OF APP BAY
OVERHEAD DOORS (TYP)
2'
8'
CJ
TYP
CONC
OVERFLOW
SCUPPER
MTL-1MTL-2 MTL-2
M A
X B
U
IL
D
IN
G H
E
IG
H
/8
TOP OF SLAB
0' - 0"
T/ MAS APP BAY
19' - 4"
T/ MAS L.Q.
10' - 8"
4"
1'-0"
3"
1'-0"
CMU-1
CMU-1
MTL-2
WD-1
OH SECTIONAL DOOR
CMU-2
CMU-2
RF-1
A302
A302
A302
A302
A301
A301
A301
A301
CMU-1A
170B 170C 170D 170E
158B 130B
RF-3
MTL-1
CMU-1A
CMU-2A
MTL-1
CMU-1
CMU-1A
CMU-2
MTL-1
CMU-2A
PREFAB METAL
CANOPY
SCREEN WALL
DOWNSPOUT
(TYP) - SEE ROOF
PLAN
OVERFLOW
SCUPPER
10"
1'-0"
CJ
MTL-1MTL-2 MTL-2
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
ELEVATIONS
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A202
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
1/8" = 1'-0"
NORTH ELEVATION
1/8" = 1'-0"
SOUTH ELEVATION
DRAWINGS REMOVED
REVISIONS
# DATE DESCRIPTION
3 07/12/2024 VE Rev 1
4 09/05/2025 90% IRC REVIEW
T/ MAS APP BAY
19' - 4"
T/ MAS L.Q.
10' - 8"
CONC FOOTING - SEE
STRUCT
8" CMU-SMOOTH FACE
BELOW GRADE - GROUT
SOLID
8" CMU-SPLIT FACE
BELOW GRADE - GROUT
SOLID
8" CMU-SPLIT FACE -
GROUT PER STRUCT.
OTHERWISE FILL WITH
FOAM INSULATION
TYPICAL ROOFING ASSEMBLY UON =
STANDING SEAM METAL ROOFING OVER
UNDERLAYMENT ON ROOF SHEATHING
(SEE STRUCT)
TYP FASCIA = PREFIN ALUM
BRAKE MTL CLADDING OVER
P.T. WOOD 2X6 & 1X8
PREFIN ALUM
DRIP
TRUSS TIE-DOWN -
SEE STRUCT
2X4 BLOCKING
UN-VENTED
ALUMINUM SOFFIT
CONC SLAB ON GRADE ON
VAPOR BARRIER ON
COMPACTED SUBGRADE -
SEE STRUCT
CONSTRUCTION JOINT
5/8" GWB ON Z-FURRING @
24" O.C. WITH 2" RIGID
INSULATION (TYP @ EXT
WALLS OF CONDITIONED
SPACE)
WOOD ROOF TRUSSES @
24" O.C. - LAST TRUSS IS A
FULL TRUSS (NOT
SCISSOR)
SPRAY APPLIED OPEN
CELL INSULATION - R-30
AVE
WALL SHEATHING OVER
GABLE WALL FRAMING
THRU-WALL FLASHING -
MORTAR NET SYSTEM
@ BASE OF WALL (TYP)
S M
O O
T H
F A
C E
2'
S P
LI
T
F A
C E
9'
S M
O O
T H
C M
U
8"
2x6 EAVE OUTRIGGER - SEE
STRUCT
HOLD TOP CHORD OF
TRUSS DOWN TO
SUPPORT OUTRIGGER
FRAMING FOR
INTERIOR WALL
FINISH = 2 1/2" MTL
STUDS @ 16" O.C.
GWB CEILING
PREFIN ALUM BRAKE
METAL FLASHING OVER
WATERPROOFING ON
P.T. 2X BLOCKING
METAL WALL PANEL
OVER AIR & WATER
BARRIER ON WALL
SHEATHING
4 1/8"
EAVE
3' - 6"
FUR OUT WALL 1/2" AS
NECESSARY WHERE
CEILING IS ABOVE 9-4"
(TYP)
STEP
1/2"
3 1/2"
MEETING
TOP OF SLAB
0' - 0"
T/ MAS L.Q.
10' - 8"
4"
CONC FOOTING - SEE
STRUCT
8" CMU-SMOOTH FACE
BELOW GRADE - GROUT
SOLID
CONC SLAB ON GRADE ON
VAPOR BARRIER ON
COMPACTED SUBGRADE -
SEE STRUCT
ALUM STOREFRONT ENTRY
SYSTEM
MEETING
PRE-ENG ALUM COVER
PROVIDE FLASHING ABOVE
ALUM COVER - CUT INTO
MORTAR JOINT & SET IN
SEALANT
TYPICAL ROOFING ASSEMBLY UON = STANDING SEAM
METAL ROOFING OVER UNDERLAYMENT ON ROOF
SHEATHING (SEE STRUCT)
PREFIN ALUM
GUTTER
TYP FASCIA = PREFIN ALUM
BRAKE MTL CLADDING OVER
P.T. WOOD 2X6 & 1X8
PREFIN ALUM
DRIP
TRUSS TIE-DOWN -
SEE STRUCT
2X4 BLOCKING
UN-VENTED
ALUMINUM SOFFIT
WOOD SCISSOR ROOF
TRUSSES @ 24" O.C.@
MEETING ROOM ONLY
SPRAY APPLIED OPEN CELL
INSULATION - R-30 AVE
WALL SHEATHING
H E
E L
9"
S M
O O
T H
F A
C E
2'
8"
5 3/8"
STEP
1/2"
3"
1'-0"
1"
8'
1'
1"
EAVE
1' - 4"
GWB CEILING - SEE RCP
A604
TOP OF SLAB
0' - 0"
T/ MAS L.Q.
10' - 8"
CONC FOOTING - SEE
STRUCT
8" CMU-SMOOTH FACE
BELOW GRADE - GROUT
SOLID
8" CMU-SPLIT FACE
BELOW GRADE - GROUT
SOLID
GROUT PER STRUCT.
OTHERWISE FILL WITH
FOAM INSULATION
8" U-BLOCK AT
WINDOW SILL
8" CMU LINTEL - SEE
STRUCT
ALUM STOREFRONT
SYSTEM
ALUM SILL
CEILING - SEE RCP
8'
S M
O O
T H
F A
C E
2'
H E
E L
9"
TYPICAL ROOFING
ASSEMBLY UON =
STANDING SEAM METAL
ROOFING OVER
UNDERLAYMENT ON ROOF
SHEATHING (SEE STRUCT)
PREFIN ALUM
GUTTER
TYP FASCIA = PREFIN ALUM
BRAKE MTL CLADDING OVER
P.T. WOOD 2X6 & 1X8
PREFIN ALUM
DRIP
TRUSS TIE-DOWN -
SEE STRUCT
2X4 BLOCKING
UN-VENTED
ALUMINUM SOFFIT
CONC SLAB ON GRADE ON
VAPOR BARRIER ON
COMPACTED SUBGRADE -
SEE STRUCT
CONSTRUCTION JOINT
5/8" GWB ON Z-FURRING @
24" O.C. WITH 2" RIGID
INSULATION (TYP @ EXT
WALLS OF CONDITIONED
SPACE)
GWB STOOL (TYP UNO) 1"
WOOD ROOF TRUSSES @
24" O.C.
SPRAY APPLIED OPEN CELL
INSULATION - R-30 AVE
WALL SHEATHING
THRU-WALL FLASHING -
MORTAR NET SYSTEM
@ BASE OF WALL (TYP)
1'
PRE-ENG ALUM COVER
WHERE OCCURRINGSTEP
1/2"
EAVE
1' - 4"1"
TOP OF SLAB
0' - 0"
T/ MAS APP BAY
19' - 4"
T/ MAS L.Q.
10' - 8"
3' - 6" 4 1/8"
P O
LI
S
H E
D F
A C
E
2'
S P
LI
T
F A
C E
8'
1'
8'
CONC FOOTING - SEE
STRUCT
8" CMU-SMOOTH FACE
BELOW GRADE - GROUT
SOLID
8" CMU-SPLIT FACE
BELOW GRADE - GROUT
SOLID
GROUT PER STRUCT.
OTHERWISE FILL WITH
FOAM INSULATION
CONC SLAB ON GRADE ON
VAPOR BARRIER ON
COMPACTED SUBGRADE -
SEE STRUCT
CONSTRUCTION JOINT
5/8" GWB ON Z-FURRING @
24" O.C. WITH 2" RIGID
INSULATION (TYP @ EXT
WALLS OF CONDITIONED
SPACE)
THRU-WALL FLASHING -
MORTAR NET SYSTEM
@ BASE OF WALL (TYP)
TYPICAL ROOFING ASSEMBLY UON =
STANDING SEAM METAL ROOFING OVER
UNDERLAYMENT ON ROOF SHEATHING
(SEE STRUCT)
TYP FASCIA = PREFIN ALUM
BRAKE MTL CLADDING OVER
P.T. WOOD 2X6 & 1X8
PREFIN ALUM
DRIP
TRUSS STRAP - SEE
STRUCT
2X4 BLOCKING
UN-VENTED
ALUMINUM SOFFIT
WOOD ROOF TRUSSES @
24" O.C.
SPRAY APPLIED OPEN
CELL INSULATION - R-30
AVE
WALL SHEATHING OVER
GABLE WALL FRAMING
2x6 EAVE OUTRIGGER - SEE
STRUCT
HOLD TOP CHORD OF
TRUSS DOWN TO
SUPPORT OUTRIGGER
CEILING - SEE RCP
PREFIN ALUM BRAKE
METAL FLASHING OVER
WATERPROOFING ON
P.T. 2X BLOCKING
METAL WALL PANEL
OVER AIR & WATER
BARRIER ON WALL
SHEATHING
2' - 0"
WOOD BEAM - SEE
STRUCT
CMU WALL @ MIDDLE -
SEE PLAN
STEP
1/2"
LOCKER
A503
SIM
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
WALL
SECTIONS
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A311
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
KEYNOTE LEGEND
3/4" = 1'-0"
WALL SECTION @ GABLE END INSET
3/4" = 1'-0"
WALL SECTION @ EAVE W/ FH WIN
3/4" = 1'-0"
WALL SECTION @ EAVE W/ WINDOW
3/4" = 1'-0"
WALL SECTION @ GABLE END BUMP OUT
REVISIONS
# DATE DESCRIPTION
4 09/05/2025 90% IRC REVIEW
A7013
SA6A
S A
A
SA6A
9'
3/ 4"
T3B
T2
WOMEN
MEN
7' - 6 5/8"
4' - 5 3/8"
1'
/2
"105 106SA4A
S A
A
S A
A
T6C
T6C
T10T10
T1T1
T4
T17BT17B
FD FD
MILLWORK
VANITY
3'
MIN
18" CLR
QS-1 QS-1
KITCHEN
P A
N T
R Y
-C
O M
P S
IN
K
C
T R
N
W
D
O W
C O
F F
E E
M A
K
U P
P L
IE
S
P A
N T
R Y
P A
N T
R Y
DINING
A703
7 6
A703
A703
A703 A703
A703
1'
/8
5/ 8"
2'
9'
SA4
S A
2' - 2" 16' - 1 5/8" 2' - 5"
A P
P
APP4
APP5
A P
P
A P
P
8' - 5 3/8" 4' - 9" 5' - 0" 2' - 1"
3/ 4"
2'
1/ 2"
3/ 4"
2'
ALIGN
3'
/8
7'
2' - 0" 4' - 6"
1' - 2"
1' - 8 1/2"
4'
/4
2'
3' - 7 7/8"
2'
2'
2'
2'
/4
S A
A
42" HIGH BAR
TOP
34" HIGH
COUNTERTOP
36" HIGH
COUNTERTOP
Q S
-1
QS-1
SS-1
SS-1
QS-1
SA4A
SA4ASA4A
ALIGN
A702 13
A702
A702 10
A702
A702
A702 4
LAUNDRY
LOCKERS
CORR
SHOWER RM
IT
A703 13
SA4
SA4
SA4
SA4
SA4
SA4
S A
SA4A
S A
3'
1/ 2"
5'
/2
/2
C
14' - 4" 11' - 3 3/8" 4 1/4"
4' - 6"
A L
IG
N
4' - 3 3/8" 7' - 0"
3'
/8
3'
3'
3'
1'
ALIGN
10' - 3 5/8" 5' - 0" 11' - 0"
5' - 8"
5' - 6"
1'
/8
3'
3'
1'
/2
TYP
T3A
3'
/8
3'
3'
/8
LINEAR DRAIN AT BACK
OF SHOWER - SLOPE
ONE DIRECTION (TYP)
SHOWER HEAD (TYP)
ADA SHOWER HEAD
TYP
T9
TYP
T10
T15
T18
TYP
T11/T12
TYP
T7B
T6A
T6A
UTILITY
SINK
W
D
WATER
HEATER
JAN
SINK
DOUBLE-TIER
LOCKERS
(15"W x 24" DP)
ALIGN
2' - 0" 2' - 0"
5' - 6" 5' - 6"
3' - 3"
M
IN
123A
120 121
FD
FD
FD
FD
WOOD BENCH
9'
/2
SA4A
SA4A
S A
A
S A
A
SA4A
EQ EQ
1' - 3 3/4"
1' - 3 3/4"
4'
/2
SLOPE
SLOPE
SLOPE
SLOPE
APP8
QS-1
A703
TYP
T11/T12
7' - 3 1/4"
A704
A702
A702 1211
CAPT RR
CAPT SUITE
7'
/2
3'
3'
3'
1/ 8"
3' - 4"
A L
IG
N
WORK SURFACE(3) LOCKERS
21"x24"x84"
9' - 9"
2' - 0"
LINEAR DRAIN AT BACK
OF SHOWER - SLOPE
ONE DIRECTION (TYP)
Q S
-1
T3A
T6A
PROVIDE BLOCKING FOR FUTURE
GRAB BARS AT TOILET & SHOWER
T9
T10
T7B
2'
/2
PROVIDE FINISHED
END ON EXPOSED
LOCKERS (TYP) SG4.5A
F Z
A
M A
S A
A
SA4A
S G
.5
A
SA4A
FD
PL-2
T11/T12
EQ EQ
A702
A702
W/C
BUNK 12
BUNK 13
LO
C
K E R
MECH
LOCKER
SG4.5A
SG4.5A
S G
.5
A
FD
2'
1'
2'
3'
8" 8"
7'
7'
5' - 10 7/8" 9' - 9 5/8"
15' - 8 3/8"
3'
3'
5' - 6"
T6A
T3A
D E
S K
*ALL FURNITURE IS BY OWNER (NIC)
T2
T1
(3) LOCKERS
21"x24"x84"
3'
T Y
P
2'
TYP
2' - 0"
TWIN BED *
CHAIR *
A803
A702
A70216
A702
A702 21
WOMEN
SA4
M8M8
S A
SA4
S A
M M
F S
A
T17A
160B
5' - 0"
FS3A
4"
F2
6'
E Q
E Q
2' - 4" 1' - 4"
17' - 7 5/8"
3'
3'
5'
/8
1' - 4"
160A
5' - 3 1/8"
A L
IG
N5' - 8"
LI
N
N
C
LO
S E
T
2'
/2
F S
A
3 5/8"
T6A
T15
T18
T11/T12
T9
T10
T7B
LINEAR DRAIN AT BACK
OF SHOWER - SLOPE
ONE DIRECTION (TYP)
TYP
T3A
MILLWORK VANITYDOUBLE-TIER
LOCKERS
(15"W x 24" DP)
3'
/2
4"
3' - 0" A703 12
T11/T12
A L
IG
N
T20
24X36 SS
MOP SINK
3'
FD
A702
DECON
164A
164B
EXTRACTOR
EXTRACTOR SLAB - SEE
MNF REQUIREMENTS -
SEE STRUCT
CATCH BASIN - SEE
PLUMB
RECESSED LINT
INTERCEPTOR - SEE
PLUMB
STAINLESS STL WASH
TABLE BY GC. SIZE AS
INDICATED. SEE
PLUMBING FOR FIXTURE
SPECS
H20 HEATER WALL
MOUNTED ABOVE
DRYER - SEE PLUMB
FRONT LOAD DRYER
APP7
APP9
APP13
GEAR DRYER. BY
OWNER
5' - 0"
3'
DATE:
PROJECT NO.:
THIS DRAWING IS AN INSTRUMENT OF SERVICE
AND IS THE PROPERTY OF DASHER HURST
ARCHITECTS, PA. IT SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART WITHOUT
THE EXPRESS WRITTEN PERMISSION OF DASHER
HURST ARCHITECTS, PA.
DASHER HURST
1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8
A R C H I T E C T S
J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4
P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0
F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5
W. W. W. D A S H E R H U R S T . C O M
ENLARGED
PLANS
22003
6.23.2023
C
O U
N T Y
R O
A D
G R
E E N
C O
V E S
P R
IN
G
S F L
A401
BID DOCUMENTS
C
LA
Y C
O U
N
TY
C
LA
Y C
O F
IR
E S
TA
TI
O N
STRUCTURAL ENGINEER
G.M. HILL ENGINEERING,
INC.
9700 PHILIPS HWY, SUITE 101
JACKSONVILLE, FL 32256
MEP ENGINEER
POWELL & HINKLE
ENGINEERING, P.A.
1409 KINGSLEY AVENUE, BLDG 12A
ORANGE PARK, FL 32073
CIVIL ENGINEER
GOODSON BERGEN &
ASSOC
11555 CENTRAL PARKWAY, SUITE 103
JACKSONVILLE, FL 32224
1/4" = 1'-0"
ENLARGED RESTROOM- PUBLIC
1/4" = 1'-0"
ENLARGED KITCHEN PLAN
1/4" = 1'-0"
ENLARGED SHOWER ROOM
1/4" = 1'-0"
ENLARGED CAPTAIN'S SUITE1/4" = 1'-0"
ENLARGED TYPICAL BUNK ROOM
1/4" = 1'-0"
ENLARGED WOMEN'S BATHROOM
1/4" = 1'-0"
ENLARGED DECON.
3. ALL FINISHES LISTED AS "STAINLESS STEEL" SHALL BE SATIN FINISHED.
2. ALL EXPOSED PIPES UNDER COUNTER TO RECEIVE PIPE COVERS, REFERENCE PRODUCT CODE LEGEND
1. REFER TO DRAWINGS FOR ALL MOUNTING HEIGHTS AND ADA REQUIREMENTS, SPECIFICATIONS, PIPE CONNECTIONS AND PLUMBING EQUIPMENT SIZES, ETC.
GENERAL NOTES
T20 SHELF BRADLEY…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .