This is an Addendum #1 to Section 10425 (Signs) of the specifications for Clay County Fire Station No. 24 construction project in Green Cove Springs, Florida. The addendum specifies signage requirements including cast metal plaques, dimensional letters and numbers, and acrylic panel signs for the new fire station facility. Key products include a 36-inch diameter cast metal plaque with the Fire and Rescue Department seal to be installed on 1-inch standoffs at the front facade; cut metal letters reading "CLAY COUNTY FIRE STATION 24" in Arial font at various sizes and standoff distances; monument sign identifiers; self-adhesive white vinyl address numerals (6 inches high); and multiple interior and exterior acrylic panel signs including no-smoking signage, restroom identification signs with ADA compliance and international pictograms, exit signs per NFPA standards, recycling signs, and apparatus bay door identifiers. The addendum deletes one sign type (ID3 – cut metal letters on tower). All signage must comply with American with Disabilities Act requirements. Manufacturers listed include A.R.K. Ramos for cast metal plaques and dimensional letters and Mohawk Sign Systems, Inc. or Nelson-Harkins for panel signs, with other manufacturers subject to architect approval. Materials specifications require aluminum for cast letters and plaques, acrylic plastic for panel signs with minimum flexural strength of 16,000 p.s.i., and all fasteners must be non-corrosive or hot-dipped galvanized for exterior installations. Installation requires field measurements prior to fabrication, level and plumb mounting with concealed fasteners, proper standoff distances as indicated in the schedule, and cleaning per manufacturer instructions upon completion.

The contractor must obtain camera-ready artwork from the owner prior to fabrication of the cast metal plaque bearing the Fire and Rescue Department seal. All signage installation must comply with manufacturer recommendations and project specifications regarding letter spacing, fastening methods, and wall surface preparation. The sign schedule specifies exact locations for each sign type, including placement on specific doors and structural elements throughout the facility. No pricing information, set-asides, or funding sources are detailed in this signage addendum, as these are standard specifications amendments. The project timeline requires substantial completion by March 15, 2027, with final Certificate of Occupancy by March 20, 2027, to meet grant deadline requirements as noted in the overall construction solicitation.

View the file

Other files

File Type Posted
Construction_of_Clay_County_Fire_Station_No._24_(Addendum_#2_Revision).pdf PDF
Demolition_Asbestos_Survey_Report_.pdf PDF
Tile_Image_.jpg JPG image
07410-STANDING_SEAM_MTL_ROOFING_(Per_Addendum_1).pdf PDF
01260-CONTRACT_MOD_(per_Addendum_1).pdf PDF
01100_Owner_Furnished_Items_(Per_Addendum_1).pdf PDF
@TOC_(Per_Addendum_1).pdf PDF
266612-ASCO_ATS_ELEC_(per_Addendum_1).pdf PDF
Addendum_#1_-_266301-ELEC_TANK_SPEC_(per_Addendum_1).pdf PDF
Addendum_#1_-_266120-ELEC_GENSET_.pdf PDF
Addendum_#1_-_230000-HVAC_.pdf PDF
Addendum_#1_-_12511-Window_Blinds_.pdf PDF
Addendum_#1_-_11452-Appliances_.pdf PDF
Addendum_#1_-_10500-Mobile_PPE_Lockers_.pdf PDF
Addendum_#1_-_Clay_Co_FS24_-_Arch_(2026_02-17)_.pdf PDF
Addendum_#1_-_Clay_Co_FS_24_-_Plum_(2026_02-17)_.pdf PDF
Addendum_#1_-_Clay_Co_FS_24_-_Mech_(2026_02-17).pdf PDF
Addendum_#1_-_Clay_Co_FS_24_-_FP_(2026_02-17).pdf PDF
Addendum_#1_-_Clay_Co_FS_24_-_Civil_(2026_02-17)_.pdf PDF
Addendum_#1_-_Clay_Co_FS24_-_Struct_(2026_02-17).pdf PDF
Addendum_#1_-_Clay_Co_FS24_-_Landscape_(2026_02-17).pdf PDF
Addendum_#1_-_Clay_Co_FS24_-_Elec_(2026_02-17).pdf PDF
Construction_of_Clay_County_Fire_Station_No._24.pdf PDF
Standard_Protection_Measures-Eastern_Indigo_Snake.pdf PDF
Indigo_Snake_Poster.pdf PDF
Clay_Co_Fire_Station_24_(2026_01-02)_Specifications-Bid_Set.pdf PDF
Clay_Co_FS24_AV_Documents_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Purvis_Documents_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Plumb_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Mech_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_FP_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Elec_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Struct_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Arch_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Landscape_Arch_(2026_01-02)_Bid_Set.pdf PDF
Clay_Co_FS24_Civil_(2026_01-02)_Bid_Set.pdf PDF
Owner_Direct_Purchase_Program.pdf PDF
Appendix_II_for_2_CFR_Part_200.pdf PDF
FEMA_Field_Manual.pdf PDF
Subgrant-Agreement-226-SR-DR-4283-Executed-Funding-Agreement-Clay-County-460634-53096.pdf PDF
W-9_(2024).pdf PDF
Certificate_of_final_payment.pdf PDF
Certificate_of_partial_payment.pdf PDF
Chapter_8_Section_I.pdf PDF
EFT_FORM.pdf PDF
Warranty_Letter_.pdf PDF
Performance_&_Paymt_Bond.doc DOC document
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLAY CO FIRE STATION 24 10425-1 SIGNS

DHA COMM. NO. 22003

SECTION 10425

SIGNS

REVISED PER ADDENDUM #1

PART 1 - GENERAL

1.1 SUMMARY

A. This Section includes the following types of signs:

1. Cast Metal Plaque.

2. Dimensional Letters & Numbers.

3. Panel signs.

1.2 SUBMITTALS

A. Product data for each type of sign specified, including details of construction relative to materials, dimensions of individual components, profiles, anchoring and finishes.

B. Dimensional Letters: Provide full-size representative samples of each dimensional letter type required, showing letter style, color, and material finish and method of attachment.

1.3 QUALITY ASSURANCE

A. Sign Fabricator Qualifications: Firm experienced in producing signs similar to those indicated for this Project, with a record of successful in-service performance, and sufficient production capacity to produce sign units required without causing delay in the Work.

1.4 PROJECT CONDITIONS

A. Field Measurements: Take field measurements prior to preparation of shop drawings and fabrication to ensure proper fitting. Show recorded measurements on final shop drawings.

Coordinate fabrication schedule with construction progress to avoid delay.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated in the Work include the following:

1. Manufacturers of Cast Metal Plaques and Dimensional Letters:

a. A.R.K. Ramos

2. Manufacturers of Panel Signs:

a. Mohawk Sign Systems, Inc.

b. Nelson-Harkins.

c. Others as approved by Architect

2.2 DIMENSIONAL LETTERS

A. Cast Letters and Numbers: Form individual letters and numbers by casting. Produce characters with smooth, flat faces, sharp corners, and precisely formed lines and profiles, free from pits, CLAY CO FIRE STATION 24 10425-2 SIGNS scale, sand holes, or other defects. Cast lugs into the back of characters and tap to receive threaded mounting studs. Comply with requirements indicated for finish, style, and size.

1. Metal: Aluminum.

2. Font: Equal to “Helvetica Medium” as manufactured by A.R.K. Ramos; size 8" tall.

3. Finish: Painted, color equal to A.R.K. Ramos

B. Use concealed fasteners fabricated from metals that are not corrosive to the sign material and mounting surface.

C. Anchors and Inserts: Use nonferrous metal or hot-dipped galvanized anchors and inserts for exterior installations and elsewhere as required for corrosion resistance.

2.3 PANEL SIGNS

A. Panel Signs: Comply with requirements indicated for materials, thicknesses, finishes, colors, designs, shapes, sizes and details of construction.

B. Material: Provide cast (not extruded or continuous cast) methyl methacrylate monomer plastic sheet in sizes and thicknesses indicated, with a minimum flexural strength of 16,000 p.s.i when tested according to ASTM D790, with a minimum allowable continuous service temperature of 176 deg F, and of the following general types.

1. Opaque Sheet: Where sheet material is indicated as “opaque”, provide colored opaque acrylic sheet in colors and finishes as selected from the manufacturer’s standards.

C. Unframed Panel Signs: Fabricate signs with edges mechanically and smoothly finished to conform with the following requirements:

1. Edge Condition: Square cut, edge color same as face.

2. Corner Condition: Corners rounded to a 3/4" radius.

3. Material: Acrylic plastic.

4. Graphic Content and Style: Provide sign copy that complies with the requirements indicated for size, style, spacing, content, position, material, finishes and colors of letters, numbers, and other graphic devices. Provide signage in accordance with the American with Disabilities Act and the sign schedule at the end of this section.

5. Applied Copy: Die-cut characters from vinyl film with pressure-sensitive adhesive backing.

Apply copy to the exposed face of the sign panel.

6. Panel Material: Matte finished opaque acrylic sheet.

2.4 CAST METAL PLAQUES

A. Plaques: Castings shall be free from pits, scale, sand holes, or other defects. Comply with requirements specified for metal, border style, background texture, and finish and with requirements shown for thickness, size, shape, and copy. Hand-tool and buff borders and raised copy to produce the manufacturer's standard satin polished finish.

1. Material: Aluminum.

2. Border Style: Equal to A.R.K. Ramos #504 custom round.

3. Background Texture: Manufacturer's standard matte finish.

4. Background Finish: Provide the manufacturer's standard acrylic baked-enamel finish.

Color to be equal to A.R.K. Ramos “Gun Metal Grey”.

5. Finish: Raised areas to be satin.

6. Design: Clay County Fire and Rescue Department Seal (see attached copy at the end of this section. County shall provide artwork.

PART 3 - EXECUTION

CLAY CO FIRE STATION 24 10425-3 SIGNS

3.1 INSTALLATION

A. General: Locate sign units and accessories where indicated, using mounting methods of the type described and in compliance with the manufacturer's instructions.

1. Install signs level, plumb, and at the height indicated, with sign surfaces free from distortion or other defects in appearance.

B. Dimensional Letters and Numbers: Mount letters and numbers using standard fastening methods recommended by the manufacturer for letter form, type of mounting, wall construction, and condition of exposure indicated. Provide heavy paper template to establish letter spacing and to locate holes for fasteners.

1. See schedule for standoff distance.

D. Cast Metal Plaques: Mount plaques using the standard method recommended by the manufacturer for the type of wall surface indicated.

1. Concealed Mounting: Mount the plaques by inserting threaded studs into tapped lugs on the back of the plaque. Set in predrilled holes filled with quick-setting cement.

3.2 CLEANING AND PROTECTION

A. After installation, clean soiled sign surfaces according to the manufacturer's instructions. Protect units from damage until acceptance by the Owner.

3.3 SIGN SCHEDULE

TYPE QTY

SIGN SCHEDULE

GRAPHIC CONTENT BRAILLE

SEAL1 1 ea

CAST METAL PLAQUE

INSTALL ON 1” STANDOFFS

SIZE = 36” DIAMETER

(one at front facade) See exterior elevations

NO

SEAL2 1 ea

CUT METAL LETTERS – POWDER COATED

MOUNT UNDER THE ROUND SEAL

INSTALL ON 1” STANDOFFS

TEXT = CLAY COUNTY FIRE STATION 24

FONT = ARIAL

SIZE = 4” HIGH, 3/4” THICK

SEE MONUMENT SIGN ELEVATIONS FOR FONT AND SIZE

NO

ID1 2 ea

CUT METAL LETTERS ON MONUMENT SIGN – POWDER COATED

INSTALL DIRECTLY ON SUBSTRATE

TEXT = CLAY COUNTY FIRE STATION

FONT = ARIAL BLACK

SEE MONUMENT SIGN ELEVATIONS FOR FONT AND SIZE

NO

ID2 2 ea

CUT METAL LETTERS ON MONUMENT SIGN – POWDER COATED

INSTALL ON 1” STANDOFFS

TEXT = 24

FONT = ARIAL BLACK

SEE MONUMENT SIGN ELEVATIONS FOR FONT AND SIZE

NO

ID3 2 ea

THIS SIGN DELETED PER ADDENDUM #1

CUT METAL LETTERS ON TOP OF TOWER – POWDER COATED

INSTALL ON 4” STANDOFFS. PENETRATE THROUGH ACRYLIC

MATERIAL TO CONNECT DIRECTLY TO SUPPORTING

STRUCTURE.

NO

CLAY CO FIRE STATION 24 10425-4 SIGNS

SIZE = SEE TOWER ELEVATIONS

TEXT = 24

FONT = ARIAL BLACK

SEE ELEVATIONS FOR SIZE

PROVIDE QUANTITY OF ATTACHEMENTS AS REQ’D.

AD 1 ea

SELF-ADHESIVE WHITE VINYL ADDRESS NUMERALS

SIZE = 6” HIGH

FONT = ARIAL BLACK

(one at front entrance)

NO

NS 2

ACRYLIC PANEL SIGN

NO SMOKING SIGN WITH “NO SMOKING” PICTOGRAM

TEXT = “NO SMOKING WITHIN 25 FEET OF BUILDING”

SIZE = 9” X 9”

One ea at Doors 101A & 180A

YES

RRM 1 ea

ACRYLIC PANEL SIGN

INTERNATIONAL PICTOGRAM FOR MALE

TEXT = “RESTROOM”

SIZE = 9” X 9”

One at each of the following doors: 123A, 123B

YES

RRF 1 ea

ACRYLIC PANEL SIGN

INTERNATIONAL PICTOGRAM FOR FEMALE

TEXT = “RESTROOM”

SIZE = 9” X 9”

One at each of the following doors: 160A, 160B

YES

RRMH 1 ea

ACRYLIC PANEL SIGN

INTERNATIONAL PICTOGRAM FOR MALE WITH H.C. SYMBOL

TEXT = “RESTROOM”

SIZE = 9” X 9”

One at each of the following doors: 105

YES

RRFH 1 ea

ACRYLIC PANEL SIGN

INTERNATIONAL PICTOGRAM FOR FEMALE WITH H.C. SYMBOL

TEXT = “RESTROOM”

SIZE = 9” X 9”

One at each of the following doors: 106

YES

RRUH 1 ea

ACRYLIC PANEL SIGN

INTERNATIONAL PICTOGRAM FOR UNISEX RESTROOM WITH

H.C. SYMBOL

TEXT = “UNISEX RESTROOM”

SIZE = 9” X 9”

One at each of the following doors: 150

YES

EX 1 ea

ACRYLIC PANEL SIGN

EXIT SIGN PER NFPA

PICTOGRAM FOR EXIT DOOR

TEXT = “EXIT”

SIZE = 9” X 9”

Mount at interior of the following doors: 101A, 102B, 107B, 130, 164A,170F, 170G, 170P, 180A

YES

RC 1

ACRYLIC PANEL SIGN

RECYCLE SIGN

PICTOGRAM FOR RECYCLE

TEXT = “RECYCLE”

SIZE = 9” X 9”

Mount in apparatus bay near door 163.

YES

TR 1

ACRYLIC PANEL SIGN

MALTESE CROSS DENOTING ROOF TRUSSES

TEXT = “R”

SIZE = 9” X 9”

YES

CLAY CO FIRE STATION 24 10425-5 SIGNS

Mount near front door

F1 1 F1 (to be mounted on exterior of front apparatus bay door) SIZE = 8”w x 6” h Door 170B

NO

F2 1 F2 (to be mounted on exterior of front apparatus bay door) SIZE = 8”w x 6” h Door 170C

NO

F3 1 F3 (to be mounted on exterior of front apparatus bay door) SIZE = 8”w x 6” h Door 170D

NO

F4 1 F3 (to be mounted on exterior of front apparatus bay door) SIZE = 8”w x 6” h Door 170E

NO

R1 1 R1 (to be mounted on exterior of rear overhead sectional door) SIZE = 8”w x 6” h Door 170L

NO

R2 1 R2 (to be mounted on exterior of rear overhead sectional door) SIZE = 8”w x 6” h Door 170K

NO

R3 1 R3 (to be mounted on exterior of rear overhead sectional door) SIZE = 8”w x 6” h Door 170J

NO

R4 1 R3 (to be mounted on exterior of rear overhead sectional door) SIZE = 8”w x 6” h Door 170H

NO

3.4 FIRE AND RESCUE DEPARTMENT SEAL

A. Sample: The image indicated below is for reference purposes only. For fabrication of cast metal plaque, contractor shall obtain camera ready artwork from owner prior to fabrication.