This is an Addendum #1 to Section 10425 (Signs) of the specifications for Clay County Fire Station No. 24 construction project in Green Cove Springs, Florida. The addendum specifies signage requirements including cast metal plaques, dimensional letters and numbers, and acrylic panel signs for the new fire station facility. Key products include a 36-inch diameter cast metal plaque with the Fire and Rescue Department seal to be installed on 1-inch standoffs at the front facade; cut metal letters reading "CLAY COUNTY FIRE STATION 24" in Arial font at various sizes and standoff distances; monument sign identifiers; self-adhesive white vinyl address numerals (6 inches high); and multiple interior and exterior acrylic panel signs including no-smoking signage, restroom identification signs with ADA compliance and international pictograms, exit signs per NFPA standards, recycling signs, and apparatus bay door identifiers. The addendum deletes one sign type (ID3 – cut metal letters on tower). All signage must comply with American with Disabilities Act requirements. Manufacturers listed include A.R.K. Ramos for cast metal plaques and dimensional letters and Mohawk Sign Systems, Inc. or Nelson-Harkins for panel signs, with other manufacturers subject to architect approval. Materials specifications require aluminum for cast letters and plaques, acrylic plastic for panel signs with minimum flexural strength of 16,000 p.s.i., and all fasteners must be non-corrosive or hot-dipped galvanized for exterior installations. Installation requires field measurements prior to fabrication, level and plumb mounting with concealed fasteners, proper standoff distances as indicated in the schedule, and cleaning per manufacturer instructions upon completion.
The contractor must obtain camera-ready artwork from the owner prior to fabrication of the cast metal plaque bearing the Fire and Rescue Department seal. All signage installation must comply with manufacturer recommendations and project specifications regarding letter spacing, fastening methods, and wall surface preparation. The sign schedule specifies exact locations for each sign type, including placement on specific doors and structural elements throughout the facility. No pricing information, set-asides, or funding sources are detailed in this signage addendum, as these are standard specifications amendments. The project timeline requires substantial completion by March 15, 2027, with final Certificate of Occupancy by March 20, 2027, to meet grant deadline requirements as noted in the overall construction solicitation.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLAY CO FIRE STATION 24 10425-1 SIGNS
DHA COMM. NO. 22003
SECTION 10425
SIGNS
REVISED PER ADDENDUM #1
PART 1 - GENERAL
1.1 SUMMARY
A. This Section includes the following types of signs:
1. Cast Metal Plaque.
2. Dimensional Letters & Numbers.
3. Panel signs.
1.2 SUBMITTALS
A. Product data for each type of sign specified, including details of construction relative to materials, dimensions of individual components, profiles, anchoring and finishes.
B. Dimensional Letters: Provide full-size representative samples of each dimensional letter type required, showing letter style, color, and material finish and method of attachment.
1.3 QUALITY ASSURANCE
A. Sign Fabricator Qualifications: Firm experienced in producing signs similar to those indicated for this Project, with a record of successful in-service performance, and sufficient production capacity to produce sign units required without causing delay in the Work.
1.4 PROJECT CONDITIONS
A. Field Measurements: Take field measurements prior to preparation of shop drawings and fabrication to ensure proper fitting. Show recorded measurements on final shop drawings.
Coordinate fabrication schedule with construction progress to avoid delay.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated in the Work include the following:
1. Manufacturers of Cast Metal Plaques and Dimensional Letters:
a. A.R.K. Ramos
2. Manufacturers of Panel Signs:
a. Mohawk Sign Systems, Inc.
b. Nelson-Harkins.
c. Others as approved by Architect
2.2 DIMENSIONAL LETTERS
A. Cast Letters and Numbers: Form individual letters and numbers by casting. Produce characters with smooth, flat faces, sharp corners, and precisely formed lines and profiles, free from pits, CLAY CO FIRE STATION 24 10425-2 SIGNS scale, sand holes, or other defects. Cast lugs into the back of characters and tap to receive threaded mounting studs. Comply with requirements indicated for finish, style, and size.
1. Metal: Aluminum.
2. Font: Equal to “Helvetica Medium” as manufactured by A.R.K. Ramos; size 8" tall.
3. Finish: Painted, color equal to A.R.K. Ramos
B. Use concealed fasteners fabricated from metals that are not corrosive to the sign material and mounting surface.
C. Anchors and Inserts: Use nonferrous metal or hot-dipped galvanized anchors and inserts for exterior installations and elsewhere as required for corrosion resistance.
2.3 PANEL SIGNS
A. Panel Signs: Comply with requirements indicated for materials, thicknesses, finishes, colors, designs, shapes, sizes and details of construction.
B. Material: Provide cast (not extruded or continuous cast) methyl methacrylate monomer plastic sheet in sizes and thicknesses indicated, with a minimum flexural strength of 16,000 p.s.i when tested according to ASTM D790, with a minimum allowable continuous service temperature of 176 deg F, and of the following general types.
1. Opaque Sheet: Where sheet material is indicated as “opaque”, provide colored opaque acrylic sheet in colors and finishes as selected from the manufacturer’s standards.
C. Unframed Panel Signs: Fabricate signs with edges mechanically and smoothly finished to conform with the following requirements:
1. Edge Condition: Square cut, edge color same as face.
2. Corner Condition: Corners rounded to a 3/4" radius.
3. Material: Acrylic plastic.
4. Graphic Content and Style: Provide sign copy that complies with the requirements indicated for size, style, spacing, content, position, material, finishes and colors of letters, numbers, and other graphic devices. Provide signage in accordance with the American with Disabilities Act and the sign schedule at the end of this section.
5. Applied Copy: Die-cut characters from vinyl film with pressure-sensitive adhesive backing.
Apply copy to the exposed face of the sign panel.
6. Panel Material: Matte finished opaque acrylic sheet.
2.4 CAST METAL PLAQUES
A. Plaques: Castings shall be free from pits, scale, sand holes, or other defects. Comply with requirements specified for metal, border style, background texture, and finish and with requirements shown for thickness, size, shape, and copy. Hand-tool and buff borders and raised copy to produce the manufacturer's standard satin polished finish.
1. Material: Aluminum.
2. Border Style: Equal to A.R.K. Ramos #504 custom round.
3. Background Texture: Manufacturer's standard matte finish.
4. Background Finish: Provide the manufacturer's standard acrylic baked-enamel finish.
Color to be equal to A.R.K. Ramos “Gun Metal Grey”.
5. Finish: Raised areas to be satin.
6. Design: Clay County Fire and Rescue Department Seal (see attached copy at the end of this section. County shall provide artwork.
PART 3 - EXECUTION
CLAY CO FIRE STATION 24 10425-3 SIGNS
3.1 INSTALLATION
A. General: Locate sign units and accessories where indicated, using mounting methods of the type described and in compliance with the manufacturer's instructions.
1. Install signs level, plumb, and at the height indicated, with sign surfaces free from distortion or other defects in appearance.
B. Dimensional Letters and Numbers: Mount letters and numbers using standard fastening methods recommended by the manufacturer for letter form, type of mounting, wall construction, and condition of exposure indicated. Provide heavy paper template to establish letter spacing and to locate holes for fasteners.
1. See schedule for standoff distance.
D. Cast Metal Plaques: Mount plaques using the standard method recommended by the manufacturer for the type of wall surface indicated.
1. Concealed Mounting: Mount the plaques by inserting threaded studs into tapped lugs on the back of the plaque. Set in predrilled holes filled with quick-setting cement.
3.2 CLEANING AND PROTECTION
A. After installation, clean soiled sign surfaces according to the manufacturer's instructions. Protect units from damage until acceptance by the Owner.
3.3 SIGN SCHEDULE
TYPE QTY
SIGN SCHEDULE
GRAPHIC CONTENT BRAILLE
SEAL1 1 ea
CAST METAL PLAQUE
INSTALL ON 1” STANDOFFS
SIZE = 36” DIAMETER
(one at front facade) See exterior elevations
NO
SEAL2 1 ea
CUT METAL LETTERS – POWDER COATED
MOUNT UNDER THE ROUND SEAL
INSTALL ON 1” STANDOFFS
TEXT = CLAY COUNTY FIRE STATION 24
FONT = ARIAL
SIZE = 4” HIGH, 3/4” THICK
SEE MONUMENT SIGN ELEVATIONS FOR FONT AND SIZE
NO
ID1 2 ea
CUT METAL LETTERS ON MONUMENT SIGN – POWDER COATED
INSTALL DIRECTLY ON SUBSTRATE
TEXT = CLAY COUNTY FIRE STATION
FONT = ARIAL BLACK
SEE MONUMENT SIGN ELEVATIONS FOR FONT AND SIZE
NO
ID2 2 ea
CUT METAL LETTERS ON MONUMENT SIGN – POWDER COATED
INSTALL ON 1” STANDOFFS
TEXT = 24
FONT = ARIAL BLACK
SEE MONUMENT SIGN ELEVATIONS FOR FONT AND SIZE
NO
ID3 2 ea
THIS SIGN DELETED PER ADDENDUM #1
CUT METAL LETTERS ON TOP OF TOWER – POWDER COATED
INSTALL ON 4” STANDOFFS. PENETRATE THROUGH ACRYLIC
MATERIAL TO CONNECT DIRECTLY TO SUPPORTING
STRUCTURE.
NO
CLAY CO FIRE STATION 24 10425-4 SIGNS
SIZE = SEE TOWER ELEVATIONS
TEXT = 24
FONT = ARIAL BLACK
SEE ELEVATIONS FOR SIZE
PROVIDE QUANTITY OF ATTACHEMENTS AS REQ’D.
AD 1 ea
SELF-ADHESIVE WHITE VINYL ADDRESS NUMERALS
SIZE = 6” HIGH
FONT = ARIAL BLACK
(one at front entrance)
NO
NS 2
ACRYLIC PANEL SIGN
NO SMOKING SIGN WITH “NO SMOKING” PICTOGRAM
TEXT = “NO SMOKING WITHIN 25 FEET OF BUILDING”
SIZE = 9” X 9”
One ea at Doors 101A & 180A
YES
RRM 1 ea
ACRYLIC PANEL SIGN
INTERNATIONAL PICTOGRAM FOR MALE
TEXT = “RESTROOM”
SIZE = 9” X 9”
One at each of the following doors: 123A, 123B
YES
RRF 1 ea
ACRYLIC PANEL SIGN
INTERNATIONAL PICTOGRAM FOR FEMALE
TEXT = “RESTROOM”
SIZE = 9” X 9”
One at each of the following doors: 160A, 160B
YES
RRMH 1 ea
ACRYLIC PANEL SIGN
INTERNATIONAL PICTOGRAM FOR MALE WITH H.C. SYMBOL
TEXT = “RESTROOM”
SIZE = 9” X 9”
One at each of the following doors: 105
YES
RRFH 1 ea
ACRYLIC PANEL SIGN
INTERNATIONAL PICTOGRAM FOR FEMALE WITH H.C. SYMBOL
TEXT = “RESTROOM”
SIZE = 9” X 9”
One at each of the following doors: 106
YES
RRUH 1 ea
ACRYLIC PANEL SIGN
INTERNATIONAL PICTOGRAM FOR UNISEX RESTROOM WITH
H.C. SYMBOL
TEXT = “UNISEX RESTROOM”
SIZE = 9” X 9”
One at each of the following doors: 150
YES
EX 1 ea
ACRYLIC PANEL SIGN
EXIT SIGN PER NFPA
PICTOGRAM FOR EXIT DOOR
TEXT = “EXIT”
SIZE = 9” X 9”
Mount at interior of the following doors: 101A, 102B, 107B, 130, 164A,170F, 170G, 170P, 180A
YES
RC 1
ACRYLIC PANEL SIGN
RECYCLE SIGN
PICTOGRAM FOR RECYCLE
TEXT = “RECYCLE”
SIZE = 9” X 9”
Mount in apparatus bay near door 163.
YES
TR 1
ACRYLIC PANEL SIGN
MALTESE CROSS DENOTING ROOF TRUSSES
TEXT = “R”
SIZE = 9” X 9”
YES
CLAY CO FIRE STATION 24 10425-5 SIGNS
Mount near front door
F1 1 F1 (to be mounted on exterior of front apparatus bay door) SIZE = 8”w x 6” h Door 170B
NO
F2 1 F2 (to be mounted on exterior of front apparatus bay door) SIZE = 8”w x 6” h Door 170C
NO
F3 1 F3 (to be mounted on exterior of front apparatus bay door) SIZE = 8”w x 6” h Door 170D
NO
F4 1 F3 (to be mounted on exterior of front apparatus bay door) SIZE = 8”w x 6” h Door 170E
NO
R1 1 R1 (to be mounted on exterior of rear overhead sectional door) SIZE = 8”w x 6” h Door 170L
NO
R2 1 R2 (to be mounted on exterior of rear overhead sectional door) SIZE = 8”w x 6” h Door 170K
NO
R3 1 R3 (to be mounted on exterior of rear overhead sectional door) SIZE = 8”w x 6” h Door 170J
NO
R4 1 R3 (to be mounted on exterior of rear overhead sectional door) SIZE = 8”w x 6” h Door 170H
NO
3.4 FIRE AND RESCUE DEPARTMENT SEAL
A. Sample: The image indicated below is for reference purposes only. For fabrication of cast metal plaque, contractor shall obtain camera ready artwork from owner prior to fabrication.
END OF SECTION 10425