B02_Attatchment_2_26_0330_-_ROMO_KVC_326235_Final_CD_Drawing_Set_Part2.pdf
PDF 22 MB Posted
- Solicitation number
- 140P2026R0057
About this file
This is a comprehensive design and construction document package for the rehabilitation of Kawuneeche Visitor Center at Rocky Mountain National Park. The project encompasses architectural, structural, mechanical, plumbing, and electrical design drawings with specifications for a complete renovation of the existing facility.
The project scope includes demolition and rehabilitation of the admin wing, visitor center, auditorium, exhibit spaces, and comfort station. Key construction elements include removal and replacement of roofing systems, restoration of historic wood elements and trim, installation of new HVAC systems with economizers and demand-controlled ventilation, replacement of windows and doors, interior finishes including drywall and ceramic tile, new plumbing fixtures and drainage systems, electrical infrastructure upgrades, and technology systems integration. The design emphasizes compliance with Secretary of Interior Standards for historic rehabilitation, with careful attention to preserving existing historic materials including timber framing, wood board ceilings, and stone masonry. The HVAC design includes multiple furnaces with economizer mixing boxes and CO2 sensors for demand-controlled ventilation across six zones. Mechanical equipment schedules specify Trane furnaces, Mitsubishi split systems, Greenheck exhaust fans, and associated HVAC components. Structural work includes beam repairs using pressure-treated Dutchman repairs, foundation modifications, and reinforced concrete slab work. The project requires coordination across multiple trades with provisions for temporary protection of historic elements during construction, phased occupancy, and temporary utility relocation during renovation.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
165639
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
SITE DETAILS VII
C606
APPROXIMATE LOCATION OF 2 WATERLINES
PER PLANS PROVIDED BY CLIENT. PLANS
CALL FOR A 2" HDPE & 6" HDPE IN THE
ALIGNMENT. UTILITY LOCATOR CONFIRMED
THERE IS NO TRACER WIRE INSTALLED IN
ORDER TO MARK. MUST POTHOLE FOR
EXACT LOCATION.
ABANDONED WATER VAULT AND VALVES
J
L
K
2 3 4 5 76
M
8 9 10 11 12 13 14 15 16 17
H
G
F
E
D
C
B
A
AD02
AD03
AD04
BREAK
ROOM
SERVER
ROOM
MECH. /
ELEC.
115RR
RR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HALL
OFFICE
CONFERENCE
STOR
WILDERNESS
DESK
EXHIBIT
NO. 1
EXHIBIT
NO. 2
AUDITORIUM
STORAGE
STORAGE
MECH.
RM
JANITOR
MECH.
RM
WOMEN'S
RR
MEN'S
RR
JC
ADMIN
WING
VISITOR
CENTER
COMFORT
STATION
- 4
6'-
3/ 4"
- 1
7'-
5/ 8"
- 2
4'- 6 7
/8"
+/- 23'-8 1/4"
+/- 98'-9 7/8"
+/- 79'-4 7/8"
- 3
0'- 5 1
/8"
- 1
9'- 5 7
/8" 02.50
LEGEND
INSIDE FACE OF EXTERIOR WALL; REMOVE AND SALVAGE <E> WD TRIM AND
WD FURRING FOR REINSTALLATION. REMOVE <E> WALL ACCESSORIES.
REMOVE <E> ROLLER SHADES AND JAMB TRACKS AT EA. JAMB. REMOVE <E>
GYP. BD. FINISH / WD WALL PANELS FROM FLOOR TO STRUCTURE ABOVE.
REMOVE <E> WALL INSULATION FROM WALL CAVITY FROM FLOOR TO
STRUCTURE ABOVE.
<E> WINDOW TO BE REMOVED
<E> DOOR TO BE REMOVED, RE: DOOR SCHEDULE
<E> DOOR TO REMAIN, RE: DOOR SCHEDULE
<E> DOOR TO BE REMOVED AND REINSTALLED, RE: DOOR SCHEDULE
<E> ELEMENT TO REMAIN, PROTECT IN PLACE
<E> ELEMENT TO BE REMOVED
REMOVE <E> CONCRETE SLAB ON GRADE TO PROVIDE ACCESS FOR
PLUMBING WORK OR CONDUIT ROUTING. PRIOR TO DEMO LOCATE UNDER
SLAB <E> DUCTS, CONDUITS, RE: STRUCT, MECH, PLUMB AND ELEC
<E> OVERHEAD ELEMENT TO REMAIN
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
CONTRACTOR SHALL HOLD PRE-DEMOLITION SITE WALK WITH C.O.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION, AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR FULL SCOPE OF
THE DEMO WORK.
DRAWINGS SEEK TO REPRESENT THE SCOPE AND RANGE OF DEMOLITION REQUIRED BUT ARE NOT INTENDED TO BE INCLUSIVE OF ALL NECESSARY WORK. DIMENSIONS SHOWN FOR DEMOLITION ARE
APPROXIMATE. VERIFY IN FIELD EXTENT OF DEMOLITION REQUIRED TO ACHIEVE <N> WORK.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING
ELEMENTS MAY NOT BE PLUMB, LEVEL OR SQUARE.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
REFER TO AD05 FOR CEILING DEMO SCOPE.
REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR ADDITIONAL FINISH REMOVAL INFORMATION.
REFER TO A501 FOR ADDITIONAL INFORMATION ON DOOR DEMO, SALVAGE AND REUSE.
REMOVE ALL ABANDONED EXTERIOR SURFACE MOUNTED HOOKS, NAILS, CONDUIT, PIPING AND EQUIPMENT, RE: ELEC AND TECH.
GC TO REMOVE ALL FFE PRIOR TO CONSTRUCTION. COORDINATE RELOCATION TO TEMPORARY FACILITIES, STORAGE, OR DISPOSAL WITH C.O. REFER TO SPECS.
GC SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN. ALL REMOVAL/DEMO ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING AND/OR ADJACENT
HISTORIC MATERIALS.
FOR ALL ITEMS TO BE REMOVED AND SALVAGED FOR REINSTALLATION, PROVIDE TEMPORARY, SECURE, WEATHERPROOF STORAGE UNTIL REINSTALLATION.
COORDINATE ALL DEMO WORK WITH HAZARDOUS ABATEMENT, RE: SPECIFICATIONS AND HAZARDOUS MATERIALS REPORT FOR KNOWN HAZARDOUS MATERIALS AND REMOVAL REQUIREMENTS. STOP WORK AND
NOTIFY C.O. IF ANY ADDITIONAL SUSPECTED HAZARDOUS MATERIAL IS FOUND DURING DEMO.
REFER TO SHEET A511 FOR ADDITIONAL DEMO / SALVAGE INFORMATION AT WINDOW LOCATIONS.
REFER TO SHEET A502 FOR ADDITIONAL DEMO / SALVAGE INFORMATION AT VESTIBULE.
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:0
5 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
AD01
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 57 177
OVERALL DEMO
FLOOR PLANSCALEAD01
DEMO FLOOR PLAN1
A
80 168
SCALE OF FEET TRUE PLAN
KEYNOTES
02.50 REMOVE AND SALVAGE <E> LIGHT FIXTURE ON COLUMN. RETURN TO PARK
CALL FOR A 2" HDPE & 6" HDPE IN THE
ALIGNMENT. UTILITY LOCATOR CONFIRMED
THERE IS NO TRACER WIRE INSTALLED IN
ORDER TO MARK. MUST POTHOLE FOR
EXACT LOCATION.
ABANDONED WATER VAULT AND VALVES
J
L
K
2 3 4 5 76
M
8 9 10 11 12 13 14 15 16 17
A1 A1
121B
121A
A1
A1 A1A1A1
A1A1
114111
A1
A1 A1A1 A1
A1 A1
110A
A1 A1
108C
A1 A1
A1 A1
108A
107C
A2 A2
02.02
02.01
BREAK
ROOM
RR
RR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HALL
OFFICE
CONFERENCE
WILDERNESS
DESK
MECH. /
ELEC.
JC
STOR
02.13
+/- 3'-4" +/- 4'-4 7/8"
- 1
1'-
1/ 4"
+/- 100'
+/- 100'
+/- 100'
+/- 99'-6" +/
- 6
'-6
02.14
02.16 02.15
02.15
02.17
115A
02.27 02.27
02.32 02.31
02.31
02.32 02.32
02.32
02.35
02.14
02.38
02.39
108B 02.40
02.14
02.01 +/
- 9
'-6
- 1
7'- 2 1
/2"
- 2
9'- 6 5
/8"
+/- 32'-4 7/8"
+/- 9'-6 7/8"
+/- 50'-7 1/8"
+/- 48'-11 1/8" +/- 42'-7 1/2"
- 1
1'-
7/ 8"
+/- 5' - 9 1/2"
+/- 7'-9 1/8"
+/- 6'-9"
OFFICE
02.28
+/- 1' - 0"
0"
02.48
2'
- 0
+/- 1' - 6"
+/- 9' - 6"
6'
- 6
3 1 /4"
+/- 2' - 6"
1'
- 4
+/- 2' - 6"
+/- 3' - 2"
1'
- 6
+/- 6' - 0"
02.51
02.58
ALIGN DEMO FOR NEW OPENING WITH END
OF T1-11 VERTICAL BOARD WALL FINISH
02.60
122A
+/- 2'-1"
- 3
'-5
02.64
02.64
<E> ELEMENT TO REMAIN, PROTECT IN PLACE
<E> ELEMENT TO BE REMOVED
<E> DOOR TO BE REMOVED, RE: DOOR SCHEDULE
LEGEND
<E> DOOR TO REMAIN, RE: DOOR SCHEDULE
INSIDE FACE OF EXTERIOR WALL; REMOVE AND SALVAGE <E> WD TRIM FOR REINSTALLATION.
REMOVE <E> WALL ACCESSORIES AND WD OR TILE WALL BASE. REMOVE <E> ROLLER SHADES,
JAMB TRACKS, CURTAIN RODS, AND BLOCKING AT EA. WINDOW JAMB. REMOVE <E> GWB FINISH
/ WD WALL PANELS FROM FLOOR TO STRUCTURE ABOVE. REMOVE <E> WALL INSULATION
FROM WALL CAVITY FROM FLOOR TO STRUCTURE ABOVE.
<E> DOOR TO BE REMOVED AND REINSTALLED, RE: DOOR SCHEDULE
REMOVE <E> CONCRETE SLAB ON GRADE TO PROVIDE ACCESS FOR UTILITY WORK,
RE: PLUMB & ELEC
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
CONTRACTOR SHALL HOLD PRE-DEMOLITION SITE WALK WITH C.O.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION, AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR FULL SCOPE OF
THE DEMO WORK.
DRAWINGS SEEK TO REPRESENT THE SCOPE AND RANGE OF DEMOLITION REQUIRED BUT ARE NOT INTENDED TO BE INCLUSIVE OF ALL NECESSARY WORK. DIMENSIONS SHOWN FOR DEMOLITION ARE
APPROXIMATE. VERIFY IN FIELD EXTENT OF DEMOLITION REQUIRED TO ACHIEVE <N> WORK.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING
ELEMENTS MAY NOT BE PLUMB, LEVEL OR SQUARE.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
REFER TO AD05 FOR CEILING DEMO SCOPE.
REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR ADDITIONAL FINISH REMOVAL INFORMATION.
REFER TO A501 FOR ADDITIONAL INFORMATION ON DOOR DEMO, SALVAGE AND REUSE.
REMOVE ALL ABANDONED EXTERIOR SURFACE MOUNTED HOOKS, NAILS, CONDUIT, PIPING AND EQUIPMENT, RE: ELEC AND TECH.
GC TO REMOVE ALL FFE PRIOR TO CONSTRUCTION. COORDINATE RELOCATION TO TEMPORARY FACILITIES, STORAGE, OR DISPOSAL WITH C.O. REFER TO SPECS.
GC SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN. ALL REMOVAL/DEMO ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING AND/OR ADJACENT
HISTORIC MATERIALS.
FOR ALL ITEMS TO BE REMOVED AND SALVAGED FOR REINSTALLATION, PROVIDE TEMPORARY, SECURE, WEATHERPROOF STORAGE UNTIL REINSTALLATION.
COORDINATE ALL DEMO WORK WITH HAZARDOUS ABATEMENT, RE: SPECIFICATIONS AND HAZARDOUS MATERIALS REPORT FOR KNOWN HAZARDOUS MATERIALS AND REMOVAL REQUIREMENTS. STOP WORK AND
NOTIFY C.O. IF ANY ADDITIONAL SUSPECTED HAZARDOUS MATERIAL IS FOUND DURING DEMO.
REFER TO SHEET A511 FOR ADDITIONAL DEMO / SALVAGE INFORMATION AT WINDOW LOCATIONS.
REFER TO SHEET A502 FOR ADDITIONAL DEMO / SALVAGE INFORMATION AT VESTIBULE.
KEY PLAN
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:3 3:4
3 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
AD02
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 58 177
ENLARGED DEMO
PLAN - ADMIN
SCALEAD02 A
ENLARGED DEMO PLAN - ADMIN1 40 8 124
SCALE OF FEET
KEYNOTES
02.01 REMOVE ALL <E> FINISHES DOWN TO <E> FRAMING IN RESTROOMS. REMOVE <E> PLUMBING FIXTURES, ACCESSORIES, AND STALL PARTITIONS, RE: PLUMB.
02.02 REMOVE <E> WD CASEWORK, COUNTERTOP, AND STAINLESS STEEL SINK, RE: PLUMB
02.13 CAREFULLY REMOVE <E> PLYWOOD AND GWB ENCLOSURE AND WATER HEATER. PROTECT ADJACENT
FINISHES, RE: PLUMB.
02.14 CAREFULLY REMOVE <E> ADJUSTABLE WOOD SHELVES AND WALL MOUNTED METAL STANDARDS.
02.15 REMOVE <E> WALL FRAMING AND FINISHES IN PREPARATION FOR <N> DOOR. REMOVE WOOD WALL
BASE TRIM.
02.16 REMOVE <E> FLOOR-TO-CEILING PLYWOOD BUILT-IN SHELVING FOR REPLACEMENT.
02.17 REMOVE <E> WOOD FRAMED INTERIOR PARTITION, SHELVING, RAISED BOTTOM AND FRAMING, AND
TWO SLIDING WOOD DOORS.
02.27 REMOVE <E> WD FLOOR REGISTER (2) LOCATIONS IN EA. RR. LOCATION, RE: MECH.
02.28 REMOVE <E> DOOR AND INFILL, RE: STRUCT. PROTECT <E> FINISHES TO REMAIN.
02.31 <E> WD DOOR TRIM TO REMAIN. PROTECT IN PLACE. MODIFY AS REQUIRED FOR DOOR MODIFICATIONS.
02.32 CAREFULLY REMOVE AND SALVAGE HISTORIC WD TRIM FOR REINSTALLATION IN NEW LOCATION
02.35 <E> FIREHOSE CABINET TO REMAIN. PROTECT IN PLACE. REMOVE ANY WAYFINDING SIGNAGE RELATED
TO THIS HOSE CABINET.
02.38 REMOVE NON-HISTORIC WOOD CHAIR RAIL AROUND PERIMETER OF ROOM.
02.39 REMOVE NON-HISTORIC WOOD PICTURE RAIL
02.40 REMOVE NON-HISTORIC 3" BASE TRIM AROUND PERIMETER OF ROOM. RETAIN HISTORIC TYPE A TRIM
WHERE EXTANT.
02.48 REMOVE <E> FIRST AID AND DEFIBRILLATOR EQUIPMENT
02.51 <E> COLUMN TO REMAIN.
02.58 REMOVE ADDITIONAL LINOLEUM FLOORING AND METAL TRANSITION STRIPS
02.60 REMOVE <E> DOWNSPOUT
02.64 REMOVE SURFACE MOUNTED DOORBELL ON GLAZING
TRUE PLAN
CALL FOR A 2" HDPE & 6" HDPE IN THE
ALIGNMENT. UTILITY LOCATOR CONFIRMED
THERE IS NO TRACER WIRE INSTALLED IN
ORDER TO MARK. MUST POTHOLE FOR
EXACT LOCATION.
ABANDONED WATER VAULT AND VALVES
J
H
G
F
E
103B103A
6'
- 1
+/- 2' - 6"
02.04
02.03
02.03
+/- 27' - 6 1/2"
EXHIBIT
NO. 1
EXHIBIT
NO. 2
AUDITORIUM
STORAGE
STORAGE
MECH.
RM
VEST.
WILDERNESS
DESK
02.05
02.03
02.03
+/- 51'-2 5/8" +/- 27'-6 1/2" +/- 7 3/4"
- 4
6'-
3/ 4"
- 1
9'- 5 7
/8"
+/- 79'-4 7/8"
- 7 '-0
5/ 8"
+/- 10'-9"
02.03
+/- 7'-5 1/4"
'-6 1/
4"
+/- 6'-9 3/8"
02.25
02.25
02.19
02.1902.1902.1902.19
6'-0"
02.37
ABOVE
02.42
02.44
- 1
5'- 0 1
/8"
+/- 11'-3 7/8"
5'
-1 5/8
+/- 3'-8 3/4"
'-1 1/
4"
+/- 5' - 11"
+/- 6'-2 1/2"+/- 1'-10 1/4" +/- 1'-10 1/4"
+/- 9'-11"
02.52
02.53
02.5302.61
02.62
02.62
3'
- 0
+/- 1' - 0"
8 7 /8"
+/- 23'-5 1/2"
'-2 3/
8"
+/- 10'-6 3/8"
+/- 100'
+/- 100'
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
CONTRACTOR SHALL HOLD PRE-DEMOLITION SITE WALK WITH C.O.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION, AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR FULL SCOPE OF
THE DEMO WORK.
DRAWINGS SEEK TO REPRESENT THE SCOPE AND RANGE OF DEMOLITION REQUIRED BUT ARE NOT INTENDED TO BE INCLUSIVE OF ALL NECESSARY WORK. DIMENSIONS SHOWN FOR DEMOLITION ARE
APPROXIMATE. VERIFY IN FIELD EXTENT OF DEMOLITION REQUIRED TO ACHIEVE <N> WORK.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING
ELEMENTS MAY NOT BE PLUMB, LEVEL OR SQUARE.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
REFER TO AD05 FOR CEILING DEMO SCOPE.
REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR ADDITIONAL FINISH REMOVAL INFORMATION.
REFER TO A501 FOR ADDITIONAL INFORMATION ON DOOR DEMO, SALVAGE AND REUSE.
REMOVE ALL ABANDONED EXTERIOR SURFACE MOUNTED HOOKS, NAILS, CONDUIT, PIPING AND EQUIPMENT, RE: ELEC AND TECH.
GC TO REMOVE ALL FFE PRIOR TO CONSTRUCTION. COORDINATE RELOCATION TO TEMPORARY FACILITIES, STORAGE, OR DISPOSAL WITH C.O. REFER TO SPECS.
GC SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN. ALL REMOVAL/DEMO ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING AND/OR ADJACENT
HISTORIC MATERIALS.
FOR ALL ITEMS TO BE REMOVED AND SALVAGED FOR REINSTALLATION, PROVIDE TEMPORARY, SECURE, WEATHERPROOF STORAGE UNTIL REINSTALLATION.
COORDINATE ALL DEMO WORK WITH HAZARDOUS ABATEMENT, RE: SPECIFICATIONS AND HAZARDOUS MATERIALS REPORT FOR KNOWN HAZARDOUS MATERIALS AND REMOVAL REQUIREMENTS. STOP WORK AND
NOTIFY C.O. IF ANY ADDITIONAL SUSPECTED HAZARDOUS MATERIAL IS FOUND DURING DEMO.
REFER TO SHEET A511 FOR ADDITIONAL DEMO / SALVAGE INFORMATION AT WINDOW LOCATIONS.
REFER TO SHEET A502 FOR ADDITIONAL DEMO / SALVAGE INFORMATION AT VESTIBULE.
LEGEND
<E> WALL TO REMAIN, PROTECT IN PLACE
<E> ELEMENT TO BE REMOVED
<E> DOOR TO BE REMOVED, RE: DOOR SCHEDULE
<E> DOOR TO REMAIN, RE: DOOR SCHEDULE
<E> DOOR TO BE REMOVED AND REINSTALLED, RE: DOOR SCHEDULE
REMOVE <E> CONCRETE SLAB ON GRADE TO PROVIDE ACCESS FOR
PLUMBING WORK OR CONDUIT ROUTING. PRIOR TO DEMO LOCATE UNDER
SLAB <E> DUCTS, CONDUITS, RE: STRUCT, MECH, PLUMB AND ELEC
INSIDE FACE OF EXTERIOR WALL; REMOVE AND SALVAGE <E> WD TRIM
FOR REINSTALLATION. REMOVE <E> GWB FINISH AND CAVITY
INSULATION FROM FLOOR TO STRUCTURE ABOVE.
KEY PLAN
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:3 3:4
3 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
AD03
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 59 177
ENLARGED DEMO
PLAN - AUDITORIUM &
EXHIBIT
SCALEAD03 A
ENLARGED DEMO PLAN - AUDITORIUM & EXHIBIT1
40 8 124
SCALE OF FEET
KEYNOTES
02.03 REMOVE <E> WD CASEWORK
02.04 REMOVE <E> RAISED WD PLATFORM +/-8" TALL, PADDING, AND CARPET.
02.05 REMOVE <E> WD STAIRCASE, HANDRAIL, AND RAISED FLOOR.
02.19 <E> ACOUSTIC WALL PANELS TO BE REMOVED.
02.25 REMOVE <E> T1-11 INFILL AT <E> WINDOW LOCATION. PREP AREA FOR <N> WINDOW.
02.37 REMOVE <E> PROJECTOR ROOM WINDOW AND TRIM
02.42 <E> NOAA PANEL TO REMAIN OPERATIONAL AND ACCESSIBLE TO PARK STAFF AT ALL TIMES
DURING CONSTRUCTION, COORDINATE ACCESS WITH C.O. PROTECT IN PLACE. RE: TECH
02.44 REMOVE NON-HISTORIC SIGNAGE AND WOOD SUPPORT RAILS.
02.52 REMOVE NON-HISTORIC WD CHAIR RAIL
02.53 CAREFULLY REMOVE <E> NON-HISTORIC FRP WALL FINISH
02.61 CAREFULLY REMOVE +/-30" X 40" WALL FINISH TO CREATE OPENING FOR NEW ACCESS DOOR
02.62 REMOVE <E> SLAB AND THRESHOLD BETWEEN JAMBS FOR INSTALL OF CONDUIT AND CLOSER
UNITS, DO NOT CUT INTO FOUNDATION
D
C
B
JANITOR
MECH.
RM
WOMEN'S
RR
MEN'S
RR
- 3
4'- 2 3
/4"
+/- 23'-8 1/4"
02.06
02.22
02.22
AD04
02.29
02.29
+/- 99'-3 5/8"
+/- 99'-3 5/8"
LEGEND
<E> ELEMENT TO REMAIN, PROTECT IN PLACE
<E> ELEMENT TO BE REMOVED
<E> DOOR TO BE REMOVED, RE: DOOR SCHEDULE
<E> DOOR TO REMAIN, RE: DOOR SCHEDULE
<E> DOOR TO BE REMOVED AND REINSTALLED, RE: DOOR SCHEDULE
REMOVE <E> CONCRETE SLAB ON GRADE TO PROVIDE ACCESS
FOR PLUMBING WORK, RE: PLUMB
KEY PLAN
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
CONTRACTOR TO HOLD PRE-DEMOLITION SITE WALK WITH C.O.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION, AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR FULL SCOPE OF
THE DEMO WORK.
DRAWINGS SEEK TO REPRESENT THE SCOPE AND RANGE OF DEMOLITION REQUIRED BUT ARE NOT INTENDED TO BE INCLUSIVE OF ALL NECESSARY WORK. DIMENSIONS SHOWN FOR DEMOLITION ARE
APPROXIMATE. VERIFY IN FIELD EXTENT OF DEMOLITION REQUIRED TO ACHIEVE <N> WORK.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING
ELEMENTS MAY NOT BE PLUMB, LEVEL OR SQUARE.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
REFER TO AD05 FOR CEILING DEMO SCOPE.
REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR ADDITIONAL FINISH REMOVAL INFORMATION.
REFER TO A501 FOR ADDITIONAL INFORMATION ON DOOR DEMO, SALVAGE AND REUSE.
REMOVE ALL ABANDONED EXTERIOR SURFACE MOUNTED HOOKS, NAILS, CONDUIT, PIPING AND EQUIPMENT, RE: ELEC, MECH, AND PLUMB.
GC TO REMOVE ALL FFE PRIOR TO CONSTRUCTION.
GC SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN. ALL REMOVAL/DEMO ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING AND/OR ADJACENT
HISTORIC MATERIALS.
FOR ALL ITEMS TO BE REMOVED AND SALVAGED FOR REINSTALLATION, PROVIDE TEMPORARY, SECURE, WEATHERPROOF STORAGE UNTIL REINSTALLATION.
COORDINATE ALL DEMO WORK WITH HAZARDOUS ABATEMENT, RE: SPECIFICATIONS AND HAZARDOUS MATERIALS REPORT FOR KNOWN HAZARDOUS MATERIALS AND REMOVAL REQUIREMENTS. STOP WORK AND
NOTIFY C.O. IF ANY ADDITIONAL SUSPECTED HAZARDOUS MATERIAL IS FOUND DURING DEMO.
D
REMOVE <E> OVER BUILT
GABLE ROOF STRUCTURE
DOWN TO TOP OF <E>
HISTORIC FLAT ROOF
CONSTRUCTION BELOW
SHADED AREA INDICATES:
<E> HISTORIC FLAT ROOF
STRUCTURE TO REMAIN.
PROTECT IN PLACE.
REMOVE <E> SOFFIT ADDITION
BACK TO <E> HISTORIC SOFFIT
TO REMAIN. PROTECT IN PLACE
AT <E> HISTORIC FLAT ROOF:
REMOVE REMNANTS OF <E>
ROOFING AND <E> ROOF
SHEATHING TO TOP OF <E>
HISTORIC ROOF JOIST TO
REMAIN.
<E> EXTERIOR WALL BELOW
TO REMAIN. PROTECT IN
PLACE. <E> STONE WING WALL BELOW
TO REMAIN. PROTECT IN
PLACE.
<E> CONCRETE WALKWAY
TO REMAIN
<E> HISTORIC SOFFIT TO
REMAIN. PROTECT IN PLACE.
CS FIRST
FLOOR
99' - 5 5/8"
PROTECT EXPOSED <E>
HISTORIC FRAMING TO
REMAIN IN PLACE AND FROM
ELEMENTS DURING
CONSTRUCTION.
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: B
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:3 3:4
4 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
AD04
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 60 177
ENLARGED DEMO
PLANS - COMFORT
STATION
SCALEAD04 A
ENLARGED DEMO PLAN - COMFORT STATION1
80 168
SCALE OF FEET
KEYNOTES
02.06 <E> DRINKING FOUNTAIN TO BE REMOVED, RE: PLUMB
02.22 REMOVE ALL <E> WALL AND FLOOR FINISHES IN RESTROOMS. REMOVE <E> PLUMBING FIXTURES, ACCESSORIES, AND STALL PARTITIONS, RE: PLUMB.
02.29 REMOVE <E> WALL MOUNTED BULLETIN BOARD AND MTL CASE
TRUE PLAN
SCALEAD04
DEMO WALL SECTION AT COMFORT STATION2
B
20 42
SCALE OF FEET
J
L
K
2 3 4 5 76
M
8 9 10 11 12 13 14 15 16 17
H
G
F
E
D
C
B
A
BREAK
ROOM
SERVER
ROOM
MECH. /
ELEC.
RR
RR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HALL
OFFICE
CONFERENCE
STOR
WILDERNESS
DESK
EXHIBIT
NO. 1
EXHIBIT
NO. 2
AUDITORIUM
STORAGE
STORAGE
MECH.
RM
JANITOR
MECH.
RM
WOMEN'S
RR
MEN'S
RR
JC
- 3
4'-
3/ 8"
- 1
5'- 0 1
/2"
- 5 1'-
3 3 /4"
- 8
'-7
- 7
'-2 1/
4"
- 2 4'-
6 7 /8"
- 7
'-3
+/- 56'-2" +/- 33'-3 3/8"
+/- 2'-8 3/4"
- 2 '-1
5/ 8"
- 5
'-0 5/
8"
- 5 '-1
3/ 8"
- 2
'-1 5/
8"
02.63 02.11
+/- 15'-6 1/2"
+/- 20'-3 1/2"
- 3
'-9 1/
4" 02.26
02.30
02.30
02.10
02.10 02.1002.49
02.54
02.55
LEGEND
<E> WALL, CEILING, COLUMN TO REMAIN, PROTECT IN
PLACE
<E> GYPSUM BOARD CEILING TO BE REMOVED
CATALOG AND REMOVE <E> HISTORIC 1X6 BOARD CEILING, REMOVE FOR
REHABILITATION AND REINSTALLATION, PLYWOOD SUBSTRATE TO BE REMOVED
<E> ELEMENT TO BE REMOVED
REMOVE <E> CEILING TILES AND SUSPENDED TRACK SYSTEM
ELECTRICAL, LIGHTING, AND FIRE PROTECTION ELEMENTS SHOWN FOR REFERENCE.
SEE DISCIPLINE SHEETS FOR SPECIFIC INFORMATION.
<E> HISTORIC 1X6 BOARD CEILING TO REMAIN, PROTECT IN PLACE
<E> HISTORIC WOOD BOARD CEILING TO REMAIN, PROTECT IN PLACE
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
CONTRACTOR TO HOLD PRE-DEMOLITION SITE WALK WITH C.O.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION, AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY
ALL EXISTING CONSTRUCTION AND NOTIFY C.O. OF ANY DISCREPANCY BETWEEN CONTRACT
DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING
WITH CONSTRUCTION.
REFER TO STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR FULL SCOPE OF THE
DEMO WORK.
DRAWINGS SEEK TO REPRESENT THE SCOPE AND RANGE OF DEMOLITION REQUIRED BUT ARE NOT INTENDED TO BE INCLUSIVE OF ALL NECESSARY WORK. DIMENSIONS SHOWN FOR DEMOLITION ARE
APPROXIMATE. VERIFY IN FIELD EXTENT OF DEMOLITION REQUIRED TO ACHIEVE <N> WORK.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING
ELEMENTS MAY NOT BE PLUMB, LEVEL OR SQUARE.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
REMOVE ALL ABANDONED EXTERIOR SURFACE MOUNTED HOOKS, NAILS, CONDUIT, PIPING AND
EQUIPMENT, RE: ELEC, MECH, AND PLUMB.
GC SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN. ALL
REMOVAL/DEMO ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING
AND/OR ADJACENT HISTORIC MATERIALS.
FOR ALL ITEMS TO BE REMOVED AND SALVAGED FOR REINSTALLATION, PROVIDE TEMPORARY, SECURE, WEATHERPROOF STORAGE UNTIL REINSTALLATION.
COORDINATE ALL DEMO WORK WITH HAZARDOUS ABATEMENT, RE: SPECIFICATIONS AND HAZARDOUS MATERIALS REPORT FOR KNOWN HAZARDOUS MATERIALS AND REMOVAL REQUIREMENTS. STOP WORK AND NOTIFY C.O. IF ANY ADDITIONAL SUSPECTED HAZARDOUS MATERIAL IS FOUND DURING DEMO.
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:1
1 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
AD05
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 61 177
OVERALL DEMO
REFLECTED CEILING
PLAN
SCALEAD05 A
DEMO FIRST FLOOR RCP1
80 168
SCALE OF FEET
KEYNOTES
02.10 CAREFULLY REMOVE <E> +/- 2' TALL T1-11 WALL PANEL AND ASSOCIATED FASTENERS
02.11 CAREFULLY REMOVE <E> NON-HISTORIC PANEL WRAP AROUND CORNER MULLION
02.26 <E> CEILING ACCESS HATCH. CATALOG & REMOVE HISTORIC 1X6 BOARDS. SALVAGE FOR
REINSTALLATION.
02.30 REMOVE <E> STANDING SEAM METAL ROOFING, SHEATHING, TRUSSES, SOFFIT FRAMING, AND
FASCIA AND SOFFIT, RE: STRUCT.
02.49 PROTECT <E> +/- 2' TALL T1-11 WALL PANEL IN PLACE.
02.54 REMOVE NON-HISTORIC WD TRIM AT DOOR HEADER
02.55 CAREFULLY REMOVE <E> PANEL AT INTERIOR FACE OF CLERESTORY WINDOWS
02.63 CAREFULLY REMOVE <E> NON-HISTORIC PANEL WRAP AROUND CORNER MULLION ABOVE
HORIZONTAL BAND ONLY. RETAIN PANEL WRAP BELOW BAND.
TRUE PLAN
TYP <E> NON-HISTORIC PANEL WRAP AROUND
CORNER MULLION IN EXHIBIT NO.1. TO BE
REMOVED. REFER TO KEYNOTE 02.11
TYP <E> T1-11 WALL PANEL TO REMOVE.
REFER TO KEYNOTE 02.10
NON-HISTORIC WD TRIM TO BE REMOVED AT DR 107B. REFER
TO KEYNOTE 02.54
RETAIN <E> NON-HISTORIC PANEL WRAP
AROUND CORNER MULLION (THIS CORNER AND
BELOW BAND ONLY). REMOVE UPPER PANEL
WRAP. REFER TO KEYNOTE 02.63
L
K
2 3 4 5 76
M
8 9 10 11 12 13 14 15 16 17
H
G
F
E
D
C
B
A
- 3
9'- 0 5
/8"
+/- 28'-8 3/4"
5:
5:
AD10
+/- 4' - 2"
3'
- 2
<E> ROOFING TO REMAIN, PROTECT IN PLACE
REMOVE <E> STANDING SEAM METAL ROOFING, SHEATHING, AND GABLE
TRUSSES, RE: STRUCT. AT <E> HISTORIC FLAT ROOF (BELOW GABLE
ROOF) REMOVE <E> ROOFING AND SHEATHING. RETAIN <E> HISTORIC
FLAT ROOF STRUCTURE AND PROTECT IN PLACE.
LEGEND
<E> ROOF DRAIN, PROTECT IN PLACE
REMOVE <E> EPDM ROOFING AND SHEATHING AS NEEDED FOR
INSTALLATION OF <N> RELIEF HOOD, RE: MECH
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
CONTRACTOR TO HOLD PRE-DEMOLITION SITE WALK WITH C.O.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION, AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND
REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.
REFER TO STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR FULL SCOPE OF THE DEMO WORK.
DRAWINGS SEEK TO REPRESENT THE SCOPE AND RANGE OF DEMOLITION REQUIRED BUT ARE NOT INTENDED TO BE INCLUSIVE OF ALL NECESSARY WORK. DIMENSIONS SHOWN FOR DEMOLITION ARE APPROXIMATE. VERIFY IN FIELD
EXTENT OF DEMOLITION REQUIRED TO ACHIEVE <N> WORK.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING ELEMENTS MAY NOT
BE PLUMB, LEVEL OR SQUARE.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: 100'-0" = USGS 8726.5'. COMFORT STATION FINISHED FLOOR
ELEVATION: 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
REMOVE ALL ABANDONED EXTERIOR SURFACE MOUNTED HOOKS, NAILS, CONDUIT, PIPING AND EQUIPMENT, RE: ELEC, MECH, AND PLUMB.
GC SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN. ALL REMOVAL/DEMO ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING AND/OR ADJACENT HISTORIC MATERIALS.
FOR ALL ITEMS TO BE REMOVED AND SALVAGED FOR REINSTALLATION, PROVIDE TEMPORARY, SECURE, WEATHERPROOF STORAGE UNTIL REINSTALLATION.
COORDINATE ALL DEMO WORK WITH HAZARDOUS ABATEMENT, RE: SPECIFICATIONS AND HAZARDOUS MATERIALS REPORT FOR KNOWN HAZARDOUS MATERIALS AND REMOVAL REQUIREMENTS. STOP WORK AND NOTIFY C.O. IF ANY
ADDITIONAL SUSPECTED HAZARDOUS MATERIAL IS FOUND DURING DEMO.
PROTECT ALL <E> ROOFING TO REMAIN FROM DAMAGE DURING CONSTRUCTION.
D
C
B
RE
MO
VE
E> O
VE
R
BU
ILT
G
AB
LE
R
OO
F
ST
RU
CT
UR
E
REMOVE OVER BUILT GABLE ROOF STRUCTURE
RIDGE LINE OF GABLE ROOFRIDGE LINE OF GABLE ROOF
<E> CANOPY
ROOF BELOW
TO REMAIN
<E> CANOPY
ROOF BELOW
TO REMAIN
AT HISTORIC FLAT ROOF
(BELOW GABLE) REMOVE
REMNANTS OF <E> ROOFING
AND REMOVE <E> SHEATHING.
PROTECT <E> HISTORIC FLAT
ROOF STRUCTURE IN PLACE.
DASHED LINE INDICATES
OUTLINE OF GABLE ROOF
TO BE REMOVED
AD04
SCALEAD10 A
DEMO ROOF PLAN2
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: B
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:1
3 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
AD10
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 62 177
OVERALL DEMO ROOF
PLAN
80 168
SCALE OF FEET TRUE PLAN
SCALEAD10
DEMO ROOF PLAN AT COMFORT STATION1
B
40 8 124
L
K
2 3 4 5 76
M
8 9 10 11 12 13 14 15 16 17
H
G
F
E
D
C
B
A
A
A
A201
A201 4
A202
A202
BREAK
ROOM
SERVER
ROOM
MECH. /
ELEC.
115RR
RR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HALL
OFFICE
CONFERENCE
STOR
WILDERNESS
DESK
EXHIBIT
NO. 1
EXHIBIT
NO. 2
AUDITORIUM
STORAGE
STORAGE
MECH.
RM
VEST.
JANITOR
MECH.
RM
WOMEN'S
RR
MEN'S
RR
JC
A104
A103
A102
+/- 98'-9 7/8"
- 1
'-4
1/ 8"
- 3
0'- 5 1
/8"
- 1 9'-
5 7 /8"
- 4
6'-
3/ 4"
- 1
7'-
5/ 8"
- 2
4'- 6 7
/8"
+/- 23'-8 1/4"
+/- 79'-4 7/8"
ADMIN
WING
VISITOR
CENTER
COMFORT
STATION
+/- 0' - 6"
LEGEND
INTERIOR FACE OF EXTERIOR WALL: INSTALL MINERAL WOOL BOARD INSULATION
FROM FLOOR TO STRUCTURE ABOVE WITHIN EXISTING WALL CAVITIES WITH SMART
VAPOR RETARDER AT INTERIOR, SEAL ALL <E> PENETRATIONS AND GAPS IN
EXTERIOR SHEATHING (FROM INSIDE WALL CAVITY ). INSTALL <N> GWB WALL FINISH
FROM FLOOR TO STRUCTURE ABOVE. REINSTALL SALVAGED WD TRIM AND WD
FURRING. RE: WALL TYPE 2.1 AND FINISH SCHEDULE.
<N> WINDOW, RE: A510, WINDOW SCHEDULE
<N> DOOR, RE: A501, DOOR SCHEDULE
<E> DOOR TO REMAIN, RE: A501, DOOR SCHEDULE
<E> ELEMENT TO REMAIN
<N> CONSTRUCTION, RE: G005 FOR WALL ASSEMBLIES
<E> SALVAGED DOOR REINSTALLED, RE: DOOR SCHEDULE
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN.
EXHIBIT DESIGN SHOWN FOR REFERENCE ONLY. REFER TO EXHIBIT DESIGN PACKAGE BY OTHERS FOR
DETAILS. INFRASTRUCTURE TO BE PROVIDED BY THIS PROJECT. EXHIBIT FABRICATION AND
INSTALLATION BY OTHERS.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY ARCHITECT/C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING
WITH CONSTRUCTION.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, TECHNOLOGY, FIRE PROTECTION, AND FIRE ALARM DRAWINGS FOR ADDITIONAL SCOPE.
ALL CONSTRUCTION ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING
HISTORIC MATERIALS.
ALL WORK TO COMPLY WITH SECRETARY OF INTERIOR STANDARDS FOR REHABILITATION.
REFER TO SHEET G005 FOR WALL TYPES.
REFER TO WINDOW AND DOOR SCHEDULE FOR SCOPE OF <N> AND REHABILITATION WORK.
ALL EXTERIOR FASCIAS, SOFFITS, COLUMNS, BEAMS TO REMAIN SHALL BE PREPARED AND REFINISHED.
REFER TO FINISH PLAN AND SCHEDULE FOR ADDITIONAL INFORMATION.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING
ELEMENTS MAY NOT BE PLUMB, LEVEL OR SQUARE.
PATCH AND REPAIR ALL FINISHES IMPACTED BY NEW WORK TO MATCH ADJACENT IN MATERIAL, COLOR, TEXTURE AND FINISH. TRANSITION <N> FINISHES TO BLEND AND APPEAR SEAMLESS. PROVIDE SAMPLES
TO C.O. FOR APPROVAL.
PATCH ALL MISCELLANEOUS HOLES, TO MATCH ADJACENT, UON.
PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT FINISH.
NEW PATHS AND SITE ELEMENTS ARE SHOWN FOR REFERENCE ONLY, RE: CIVIL FOR SITE ELEMENTS
AND ABAAS ROUTES.
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:1
5 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
A101
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 63 177
OVERALL FLOOR PLAN
SCALEA101 A
OVERALL FLOOR PLAN1
TRUE PLAN
80 168
II
XIII
VI
VII
VI
V
II
V
I
VI
IX
I
J
L
K
2 3 4 5 76
M
8 9 10 11 12 13 14 15 16 17
A301
A201
121B
121A
108B
114111
110A109
108C
108A
BREAK
ROOM
SERVER
ROOM
RR
RR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HALL
OFFICE
CONFERENCE
WILDERNESS
DESK
1.0
1.0
MECH. /
ELEC.
112 113
FIN TO STUD
5'-0 3/4"
STUD TO FIN
6'-9"
11.02
07.01
JC
STOR
12.03
12.04
11.01 06.01
107B
3'- 4"
122122A
1.0
1.0
1.0
+/- 100'
+/- 100'
+/- 99'-6" 115A
+/- 98'-8" +/- 49'-4" +/- 6'-2" +/- 43'-2"
- 2
9'-
1/ 2"
- 1
2'- 3 1
/2"
- 5 '-4
5/ 8"
- 1
2'- 3 3
/8"
- 2 9'-
1/
2"
10.03
A1 A1A1
A1 A1A1A1 A1A1 A1
A1 A1A1 A1A1 A1
A1 A1
A1 A1
A1 A1 A2 A2
07.10
09.04 09.04
A1
A102
+/- 4'-4 1/2"A403
A403 10
A4039
09.06
A40216
A4023
A402
12.05
12.06
A402 10
09.09 09.09
09.11
09.11
09.11
09.11 09.12
A402 4
10.05
A301
A402 12
EQ
EQ
A102
12.07
08.06 07.01
A
+/- 3' - 2"
02.35
02.51
06.21
09.0702.31
06.24
06.12
06.23
+/- 100'
LEGEND
INTERIOR FACE OF EXTERIOR WALL: REFER TO WALL ASSEMBLY ON SHEET G005.
SEAL ALL <E> PENETRATIONS AND GAPS IN EXTERIOR SHEATHING (FROM INSIDE
WALL CAVITY ). INSTALL <N> INSULATION AND GWB WALL FINISH FROM FLOOR TO
STRUCTURE ABOVE. REINSTALL SALVAGED WD TRIM AND WD FURRING. RE: FINISH
SCHEDULE.
PATCH CONCRETE AFTER PLUMBING, MECHANICAL OR ELECTRICAL INSTALLATION,
RE: PLUMB, MECH, OR ELEC. PROVIDE SMOOTH FINISH W/ <E> ADJACENT CONCRETE -
RE: FINISH SCHEDULE
<E> ELEMENT TO REMAIN
<N> CONSTRUCTION, RE: G005 FOR WALL ASSEMBLIES
<N> DOOR, RE: A501, DOOR SCHEDULE
<E> DOOR TO REMAIN, RE: A501, DOOR SCHEDULE
<E> SALVAGED DOOR REINSTALLED, RE: DOOR SCHEDULE
<N> WINDOW, RE: A510, WINDOW SCHEDULE
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: +/- 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: +/- 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY ARCHITECT/C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH
CONSTRUCTION.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, TECHNOLOGY, FIRE PROTECTION, AND
FIRE ALARM DRAWINGS FOR ADDITIONAL SCOPE.
ALL CONSTRUCTION ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING
HISTORIC MATERIALS.
ALL WORK TO COMPLY WITH SECRETARY OF INTERIOR STANDARD FOR REHABILITATION.
REFER TO SHEET G005 FOR WALL TYPES.
REFER TO WINDOW AND DOOR SCHEDULE FOR SCOPE OF <N> AND REHABILITATION WORK.
ALL EXTERIOR WOOD ELEMENTS TO REMAIN SHALL BE PREPARED AND REFINISHED.
REFER TO FINISH PLAN AND SCHEDULE FOR ADDITIONAL INFORMATION.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING ELEMENTS
MAY NOT BE PLUMB, LEVEL OR SQUARE.
PATCH AND REPAIR ALL FINISHES IMPACTED BY NEW WORK TO MATCH ADJACENT IN MATERIAL, COLOR, TEXTURE AND FINISH. TRANSITION <N> FINISHES TO BLEND AND APPEAR SEAMLESS. PROVIDE SAMPLES TO
C.O. FOR APPROVAL.
PATCH ALL MISCELLANEOUS HOLES, TO MATCH ADJACENT, UON.
PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT FINISH WITH DIRECT TO METAL PAINT.
NEW PATHS AND SITE ELEMENTS ARE SHOWN FOR REFERENCE ONLY, RE: CIVIL FOR SITE ELEMENTS AND
ABAAS ROUTES.
PROVIDE <N> DOUBLE CELL CELLULAR WINDOW SHADES AT A1 WINDOWS. RE: WINDOW SCHEDULE.
L
M
8 9
RR
RR
A40111 A401 16
112 113
A2 A2
22.03
10.0910.09
23.02 23.02
10.0710.07
10.0410.04
12.14
JC
22.0422.04
9 1 /2"
9 1 /2"
26.01
26.01
10.11 10.11
KEY PLAN
1.1
23.06
26.08
12.07
12.06
8"
1'- 6"
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: B
SCALE: C
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:3 3:5
3 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
A102
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 64 177
ENLARGED PLAN -
ADMIN
SCALEA102 A
ENLARGED PLAN - ADMIN1
40 8 124
SCALE OF FEET
KEYNOTES
02.31 <E> WD DOOR TRIM TO REMAIN. PROTECT IN PLACE. MODIFY AS REQUIRED FOR DOOR
MODIFICATIONS.
02.35 <E> FIREHOSE CABINET TO REMAIN. PROTECT IN PLACE. REMOVE ANY WAYFINDING SIGNAGE RELATED
TO THIS HOSE CABINET.
02.51 <E> COLUMN TO REMAIN.
06.01 PROVIDE <N> WD BASE CABINETS WITH FINISH END PANEL AND SOLID SURFACE COUNTERTOP WITH 4
INCH INTEGRAL BACKSPLASH AND STAINLESS STEEL SINK, RE: PLUMB
06.12 PROVIDE <N> WALL CABINETS - 24" DEEP OVER REFRIGERATOR, 12" DEEP AT OVER COUNTER. FINISH
BOTH SIDES AND END PANELS OF CABINETS
06.21 PATCH WD TRIM AND EAVE WHERE DOWNSPOUT IS REMOVED. PT TO MATCH <E> ADJACENT MATERIAL
06.23 PROVIDE <N> WD BASE CABINETS AND SOLID SURFACE COUNTERTOP WITH 4 INCH INTEGRAL
BACKSPLASH
06.24 PROVIDE <N> WD VENEER FLOATING SHELVES MOUNTED ON HEAVY DUTY HIDDEN BRACKETS
07.01 <E> DOWNSPOUTS TO CONNECT TO <N> UNDERGROUND BOOT, RE: CIVIL
07.10 INSTALL <N> WALL INFILL AT REMOVED DOOR. <N> 2X4 FRAMING, SHEATHING, INSULATION, PTD GWB, AND PTD EXTERIOR FINISH MATERIAL TO MATCH <E> IN KIND, RE: G005 FOR WALL TYPE 2.1.
08.06 BLOCK OFF <E> MECH VENT AT INTERIOR. PROVIDE <N> MINERAL WOOL INSULATION WITHIN OPENING
AND <N> GWB FINISH
09.04 PATCH FINISHES WHERE WALL OR CASEWORK WAS REMOVED. PROVIDE SMOOTH TRANSITION
BETWEEN <E> AND <N> WALL FINISHES.
09.06 INSTALL SALVAGED WD WALL BASE TRIM FROM OTHER LOCATION.
09.07 INSTALL SALVAGED WD DOOR TRIM FROM OTHER LOCATION
09.09 <N> SURFACE MOUNTED ACOUSTIC PIN BOARD 48" X 48"
09.11 INSTALL <N> WD WALL BASE TRIM TO MATCH <E>
09.12 PROVIDE WALL PATCH FOR T1-11 FINISH WHERE WATER METER REMOVED, MATCH ADJACENT
10.03 <N> METAL CORNER GUARD
10.04 INSTALL <N> SEMI RECESSED WASTE RECEPTACLE AND PAPER TOWEL DISPENSER, PROVIDE IN WALL
WD BLOCKING.
10.05 <N> SEMI-RECESSED FIRE EXTINGUISHER CABINET
10.07 <N> GRAB BARS. (1) 36" REAR, (1) 42" SIDE, AND (1) 18" VERTICAL. PROVIDE IN-WALL WD BLOCKING.
10.09 <N> ABAAS COMPLIANT LIQUID SOAP DISPENSER.
10.11 <N> ABAAS COMPLIANT COAT HOOK ON INSIDE FACE OF DOOR AT 48" AFF.
11.01 <N> FULL-SIZED REFRIGERATOR PROVIDED BY PARK, INSTALLED BY GC, MAX 33" WIDTH AND 70"
HEIGHT.
11.02 SERVER RACKS TO BE PROVIDED AND INSTALLED BY PARK, NIC. RE: TECH FOR REQUIRED CONDUIT
RUNS.
12.03 <E> COPY MACHINE PROVIDED AND INSTALLED BY PARK, NIC.
12.04 PROVIDE <N> CUSTOM WD CASEWORK FOR MAILBOXES, PACKAGE ORGANIZATION, AND GENERAL
STORAGE FULL HEIGHT
12.05 PROVIDE <N> STORAGE CABINETS WITH ADJUSTABLE WD SHELVING, EACH APPROX 2' DEEP AND 8'
TALL BY 1'-6" WIDE. ACCOMMODATE WALL GRILL IN TOE KICK, RE: MECH AND A610
12.06 INSTALL FLOOR-TO-CEILING WD BUILT-IN 2' DEEP WITH ADJUSTABLE WD SHELVING
12.07 INSTALL FLOOR-TO-CEILING WD BUILT-IN 14" DEEP WITH ADJUSTABLE WD SHELVING
12.14 INSTALL <N> SERVICE SINK, RE: PLUMBING FOR ADDITIONAL INFORMATION, INSTALL <N> FRP PANEL
FROM FLOOR TO CEILING ABOVE. PROVIDE <N> BUILT-IN WD SHELVING ON NORTH AND WEST WALLS ABOVE SERVICE SINK TO MATCH <E> CONFIGURATION. BOTTOM SHELF TO BE MOUNTED AT 3'-0" AFF.
22.03 RE: PLUMBING AND FIRE PROTECTION FOR ADDITIONAL INFORMATION AT <N> PIPING THIS AREA.
22.04 <N> FLOOR DRAIN, RE: PLUMB
23.02 <N> METAL FLOOR REGISTER, RE: MECH.
23.06 <N> PVC CONDUIT, RE: MECH
26.01 <N> POWER ASSISTED DOOR BUTTON LOCATION, FLUSH MOUNTED. INSTALL PER ABAAS, RE: ELEC.
26.08 <N> CONDUIT, RE: ELEC
SCALEA102
ENLARGED PLAN - ADMIN - RR NO. 112 AND 1132
B
30 62
SCALE OF FEET
TRUE PLAN
SCALEA102
ENLARGED PLAN - ADMIN - STORAGE3
C
10 2 31
I
VI
I
V
H
G
F
E
A301
A301
A202
103B103A
E1
E1
EXHIBIT
NO. 1
EXHIBIT
NO. 2
AUDITORIUM
STORAGE
STORAGE
105MECH.
RM
VEST.
WILDERNESS
DESK
11.03
A3
A3
107B
A301
A301
A403
107D
+/- 9'-6 7/8"
ABOVE
08.01
09.05 09.05
A403 4
A404
A404 10
A502
09.08
6'-0"
1.0
09.11
09.11 09.11
4'-7 3/4"
4'-
A404
05.03
23.03
1.4
33.01
10.012 A602
+/-100'-0"
09.11
A404 9
+/- 3' - 9"
0'
- 8
26.06
08.07
06.22
103C
A503
22.02 26.11
LEGEND
PATCH CONCRETE AFTER PLUMBING OR ELECTRICAL INSTALLATION, RE: STRUCT,
PLUMB, MECH, & ELEC. PROVIDE SMOOTH FINISH W/ <E> ADJACENT CONCRETE -
RE: FINISH SCHEDULE
<E> ELEMENT TO REMAIN
<N> CONSTRUCTION, RE: G005 ASSEMBLIES
INTERIOR FACE OF EXTERIOR WALL: INSTALL MINERAL WOOL BOARD
INSULATION FROM FLOOR TO STRUCTURE ABOVE WITHIN EXISTING WALL
CAVITIES WITH SMART VAPOR RETARDER AT INTERIOR. SEAL ALL <E>
PENETRATIONS AND GAPS (FROM INSIDE WALL CAVITY). INSTALL <N> GWB
FINISH FROM FLOOR TO STRUCTURE ABOVE. REINSTALL SALVAGED WD TRIM.
RE: FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
<N> DOOR, RE: A501, DOOR SCHEDULE
<E> DOOR TO REMAIN, RE: A501, DOOR SCHEDULE
<E> SALVAGED DOOR REINSTALLED, RE: DOOR SCHEDULE
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: +/- 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: +/- 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY ARCHITECT/C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH
CONSTRUCTION.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, TECHNOLOGY, FIRE PROTECTION, AND
FIRE ALARM DRAWINGS FOR ADDITIONAL SCOPE.
ALL CONSTRUCTION ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING
HISTORIC MATERIALS.
ALL WORK TO COMPLY WITH SECRETARY OF INTERIOR STANDARD FOR REHABILITATION.
REFER TO SHEET G005 FOR WALL TYPES.
REFER TO WINDOW AND DOOR SCHEDULE FOR SCOPE OF <N> AND REHABILITATION WORK.
ALL EXTERIOR WOOD ELEMENTS TO REMAIN SHALL BE PREPARED AND REFINISHED.
REFER TO FINISH PLAN AND SCHEDULE FOR ADDITIONAL INFORMATION.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING ELEMENTS
MAY NOT BE PLUMB, LEVEL OR SQUARE.
PATCH AND REPAIR ALL FINISHES IMPACTED BY NEW WORK TO MATCH ADJACENT IN MATERIAL, COLOR, TEXTURE AND FINISH. TRANSITION <N> FINISHES TO BLEND AND APPEAR SEAMLESS. PROVIDE SAMPLES TO
C.O. FOR APPROVAL.
PATCH ALL MISCELLANEOUS HOLES, TO MATCH ADJACENT, UON.
PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT FINISH WITH DIRECT TO METAL PAINT.
NEW PATHS AND SITE ELEMENTS ARE SHOWN FOR REFERENCE ONLY, RE: CIVIL FOR SITE ELEMENTS AND
ABAAS ROUTES.
PROVIDE <N> DOUBLE CELL CELLULAR WINDOW SHADES AT A1 WINDOWS. RE: WINDOW SCHEDULE.
KEY PLAN
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:3 3:5
4 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
A103
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 65 177
ENLARGED PLAN -
AUDITORIUM & EXHIBIT
SCALEA103 A
ENLARGED PLAN - AUDITORIUM & EXHIBIT1
40 8 124
SCALE OF FEET
KEYNOTES
05.03 <N> STEEL HANDRAIL, RE: CIVIL.
06.22 PROVIDE WD TABLE STORAGE CABINET, CONSTRUCTED OF 2X WOOD FRAMING AND PLYWOOD, PROVIDE WD BLOCKING SLOTS AT INTERIOR TO HOLD TABLES, PAINT. RE: A503
08.01 <N> WD GLASS PARTITION, HOLD 6" FROM CEILING FOR AIR CIRCULATION RE: MECH
08.07 PROVIDE <N> 36"X46" WD ACCESS PANEL DOOR FOR BUILT-IN TABLE STORAGE
09.05 <N> SURFACE MOUNTED ACOUSTIC WALL PANELS, (11) VERTICAL PANELS APPROX 6'-8" X 2'-6" AND (3)
HORIZONTAL PANELS APPROX 6'-2" X 2'-10". RE: A404 FOR APPROX LOCATIONS AND CONFIGURATION.
CONFIRM MOUNTING LOCATIONS WITH C.O.
09.08 PROVIDE PATCH AT REMOVED WINDOW OPENING WITH FINISH TO MATCH <E> ADJACENT WALL FINISH.
PROVIDE SMOOTH TRANSITION BETWEEN <E> AND <N> WALL FINISHES.
09.11 INSTALL <N> WD WALL BASE TRIM TO MATCH <E>
10.01 <N> FULLY-RECESSED FIRE EXTINGUISHER CABINET
11.03 <N> EXPANDING HEIGHT PODIUM, PROVIDED & INSTALLED BY GOVERNMENT
22.02 <N> BI-LEVEL ABAAS DRINKING FOUNTAIN WITH INTEGRAL BOTTLE FILLER AND CANE DETECTION
APRON, RE: PLUMB
23.03 CONDENSATE DISCHARGE. RE: MECH.
26.06 <N> WALL MOUNTED PROJECTOR SCREEN, RE: TECH. PROVIDE EXTRA BLOCKING IN WALL
26.11 UNDERSLAB CONDUIT TO BE FIELD COORDINATED WITH <E> UNDERSLAB DUCTWORK TO REMAIN, RE:
ELEC, TECH, & MECH.
33.01 UTILITY ENTRANCE, RE: CIVIL
I
I
V
V
VIII
VIII
V
V
I
I VI
X
I
D
C
B
A104
A104
JANITOR
MECH.
RM
WOMEN'S
RR
MEN'S
RR
A401 14
A401
A104
A104
22.01
22.01
1.2
2'- 0"
5'- 0"
10.02
10.02
1.3
1.3
26.02
26.02
02.20
02.20
22.04
22.04
5'- 5 1
/2"
5'-0"
2'-9 3/8"
- 1
0'-
7/ 8"
'-1
1"
11' - 4"
03.02
5'-0"
3'-0"3'-0"
2'-9"
2'- 9"
11'-8"
10.12
10.12
33.01
+/- 3'-0"
A602
+/- 99'-3 5/8"
+/- 99'-3 5/8"
32.03
32.03
35 3/8"35" 35" 3' - 0" +/
- 3 '-7
16"
16"
22.04
22.04
0"
3/
4" 2'-
3 1 /4"
D
C
B
A104
A104
A104
A104
05.01
RI
DG
E
VALLEY VALLEY
VALLEY VALLEY
VALLEY
1/4" / 1'-0"1/4" / 1 '-0"
1/4" / 1'-0" 1/4" / 1 '-0"
1/4" / 1'-0"
1/4" / 1'-0
VALLEY
VALLEY1/4" /
1'-0
1/4" / 1'-0"VALLEY
1/4" / 1'-0" 1/4" / 1'-0"
1/4" / 1'-0"1/4" / 1'-0"
07.15
07.15
07.15
04.01
04.01
14'-5 3/8" 14'-5 3/8"
'-3
1/ 4"
1"
7'
- 3
A601
A601
A601
R1 R1
32.03 32.03
04.01 04.01
05.01
CS FIRST
FLOOR
99' - 3 5/8"
R1
05.01
1'
- 0
1'
- 8
0'
- 4
" A601
WOMEN'S RR
MECH. RM
CS FIRST
FLOOR
99' - 3 5/8"
R1
26.02
<E> WALL TO REMAIN
<N> CONSTRUCTION, RE: G005 FOR ASSEMBLIES.
LEGEND
<N> CONCRETE, RE: STRUCTURAL. PREPARE FOR <N> TILE FINISH
<N> DOOR, RE: A501, DOOR SCHEDULE
<E> DOOR TO REMAIN, RE: A501, DOOR SCHEDULE
<E> SALVAGED DOOR REINSTALLED, RE: DOOR SCHEDULE
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
ADMIN WING/VISITOR CENTER FINISHED FLOOR ELEVATION: 100'-0" = USGS 8726.5'. COMFORT STATION
FINISHED FLOOR ELEVATION: 99'-3 5/8" = USGS 8725.8'. RE: CIVIL
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL ELEMENTS/MATERIALS TO REMAIN.
ALL EXISTING ELEMENTS ARE SHOWN BASED ON AVAILABLE INFORMATION, NON-DESTRUCTIVE FIELD OBSERVATION AND PREVIOUS DRAWINGS PROVIDED BY GOVERNMENT. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY ARCHITECT/C.O. OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH
CONSTRUCTION.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, TECHNOLOGY, FIRE PROTECTION, AND FIRE ALARM DRAWINGS FOR ADDITIONAL SCOPE.
ALL CONSTRUCTION ACTIVITIES SHALL BE EXECUTED IN A MANNER WHICH PROTECTS ALL UNDERLYING
HISTORIC MATERIALS.
ALL WORK TO COMPLY WITH SECRETARY OF INTERIOR STANDARDS FOR REHABILITATION.
REFER TO SHEET G005 FOR WALL TYPES.
REFER TO A401 FOR TOILET ACCESSORIES.
REFER TO DOOR SCHEDULE FOR SCOPE OF <N> AND REHABILITATION WORK.
ALL EXTERIOR FASCIAS, SOFFITS, COLUMNS, BEAMS TO REMAIN SHALL BE PREPARED AND REFINISHED.
REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.
VERIFY DIMENSIONS OF ALL EXISTING CONSTRUCTION IN FIELD. EXPECT THAT EXISTING BUILDING
ELEMENTS MAY NOT BE PLUMB, LEVEL OR SQUARE.
PATCH AND REPAIR ALL FINISHES IMPACTED BY NEW WORK TO MATCH ADJACENT IN MATERIAL, COLOR, TEXTURE AND FINISH. TRANSITION <N> FINISHES TO BLEND AND APPEAR SEAMLESS. PROVIDE SAMPLES TO
C.O. FOR APPROVAL.
PATCH ALL MISCELLANEOUS HOLES, TO MATCH ADJACENT, UON.
PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT FINISH WITH DIRECT TO METAL PAINT.
ALL EXTERIOR WOOD ELEMENTS (WINDOWS, BEAMS, SOFFITS, FASCIAS, COLUMNS, ETC.) SHALL BE
PREPARED AND REPAINTED.
GENTLY CLEAN ALL <E> MASONRY.
<N> RESTROOM PARTITIONS TO BE HDPE, PEDESTAL MOUNTED. REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
KEY PLAN
FRONT
VIEW
SIDE
VIEW
FRONT
VIEW
SIDE
VIEW
DOUBLE LARGE ROLL TOILET
TISSUE DISPENSER
SURFACE MOUNT
HAND DRYER
HORIZONTAL BABY CHANGING
TABLE
ACCESSIBLE WALL GRAB BARS
12"42"
KEEP 1 1/2"
AREA BELOW
BAR CLEAR
12"24"
36"
54"
39"
FRONT
VIEW
SIDE
VIEW
3'- 8"
PROTRUDING DISPENSER
BELOW GRAB BAR
23 7/8"MIN
39 1/2"MAX
FRONT
VIEW
SIDE
VIEW
SOAP DISPENSER
SIDE
VIEW
FRONT
VIEW
TOP OF SEAT
ABAAS AUTOMATIC
FLUSH VALVE
16"
ACCESSIBLE WATER CLOSET
ACCESSIBLE WALL
MOUNTED RECEPTACLE
" M
AX
"M
IN
TOILET TISSUE
DISPENSER
MOUNTING AREA
URINAL
OF
U
RI
NA
L
" T O
RI
M
13-1/2" MIN
1 1
/2"KEEP 1 1/2" AREA
BELOW BAR CLEAR
CL
4" MAX*
1 1 /2"
FRONT
VIEW
SIDE
VIEW
RECESSED WASTE
RECEPTACLE
KEEP 1 1/2"
AREA BELOW
BAR CLEAR
6"
SIDE
VIEW
FRONT
VIEW
TO
T
OP
O
F
GR
IP
PI
NG
S
UR
FA
CE
4" MAX
4" MAX
2 3/4"
2 3/4"
2 3/4"
" M
AX
" M
IN
*IF LEADING EDGE HIGHER THAN 27"
SIDE
VIEW
FRONT
VIEW
BO
TT
OM
O
F
RE
FL
EC
TI
NG
SU
RF
AC
E
RI
M
OF
S
IN
K
ACCESSIBLE WALL
MOUNTED LAVATORY
PR
OV
ID
E
UN
DE
R
LA
VA
TO
RY
P
LU
MB
IN
G
PR
OT
EC
ON
KNEE AND TOE
CLEARANCE
8" MIN "
6" MAX
11" MIN
" M
IN
17" MIN*
KNEE
TOE
*IF >17"
ADDITIONAL
SPACE MUST
PROVIDE 27"
MIN KNEE
CLEARANCE
" 34
RI
M
OF
S
IN
K
7"
SCALEA104
BUILDING SECTION - COMFORT STATION2
A
SCALEA104 A
ENLARGED PLAN - COMFORT STATION3
SCALEA104 A
ENLARGED ROOF PLAN - COMFORT STATION4
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 3/2
6 9
:19 :08
A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
A104
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 66 177
ENLARGED PLAN -
COMFORT STATION
40 84
SCALE OF FEET
SCALEA104
BUILDING SECTION - COMFORT STATION1
A
KEYNOTES
02.20 <E> VENT TO REMAIN, PROTECT IN PLACE, RE: MECH.
03.02 <N> CONCRETE HOUSEKEEPING PAD. ROUGHEN SURFACE OF <E> SLAB TO AN AMPLITUDE OF 1/2".
APPLY BONDING AGENT. PROVIDE <N> 33 "X 33" BY 6" THICK HOUSEKEEPING PAD REINFORCED WITH
#3 BARS AT 18" EACH WAY CENTERED IN THE PAD. RE: PLUMB
04.01 PROVIDE <N> CONCRETE PARGE CAP AT TOP OF EXISTING STONE WALL, SLOPE TOP TO DRAIN AWAY
FROM BUILDING.
05.01 INSTALL <N> 4" MIN. PRE-FINISHED METAL ROOF EDGE AT PERIMETER.
07.15 <N> PREFINISHED METAL SCUPPER. COLOR TO MATCH PARAPET FLASHING.
10.02 <N> WALL MOUNTED BABY CHANGING STATION
10.12 <N> ABAAS COMPLIANT RECESSED WASTE RECEPTACLE, PROVIDE IN WALL BLOCKING.
22.01 PROVIDE <N> PLUMBING FIXTURES AND ACCESSORIES, RE: PLUMB
22.04 <N> FLOOR DRAIN, RE: PLUMB
26.02 <N> ELECTRIC AUTOMATIC HAND DRYER, RE: ELEC.
32.03 <N> CONCRETE, RE: CIVIL AND STRUC
33.01 UTILITY ENTRANCE, RE: CIVIL
L
K
2 3 4 5 76
M
8 9 10 11 12 13 14 15 16 17
H
G
F
E
D
C
B
A
A301
A301
A
A
A201
A201 4
A202
A202
A202
A202
+/- 44'-8 7/8"
BREAK
ROOM
SERVER
ROOM
MECH. /
ELEC.
RR
RR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HALL
OFFICE
CONFERENCE
STOR
EXHIBIT
NO. 1
EXHIBIT
NO. 2
AUDITORIUM
STORAGE
STORAGE
MECH.
RM
JANITOR
MECH.
RM
WOMEN'S
RR
MEN'S
RR
JC
OFFICE
WILDERNESS
DESK
06.05
06.02 06.02
02.18
02.18
02.18
108'-0"
108'-0"
108'-0"
112'-10 1/2"
111'-5"
+/-107'-10"
+/-107'-3 1/2"
+/-107'-0"
- 3
0'- 5 1
/8"
- 1 9'-
5 7 /8"
- 4
6'-
3/ 4"
- 1
7'-
5/ 8"
- 2
4'- 6 7
/8"
+/- 16'-7 3/4"
+/- 4'-4"
EQ
EQ
06.0906.09
06.10
VEST.
108'-0"
12.06
12.04
EQ
EQ
26.06
21.01
107'-10"
A105
A105
EQ EQ EQ EQ
EQ EQ
EQ EQ
A106
EQ EQ
EQ EQ
EQ
EQ
CENTER OVER
LAVS
CENTER OVER
LAVS
07.16
02.56 06.21
3/
5/
/32
1/
4" 26.10
10.15
10.15
CL
ALIGN
CLALIGN
LEGEND
<N> GWB CEILING
<E> WALL OR CEILING TO REMAIN
<N> WALL, RE: G005, WALL TYPES
<E> 6" BOARD CEILING OR EXTERIOR SOFFIT, PREPARE AND REFINISH
ELECTRICAL, LIGHTING, AND FIRE PROTECTION ELEMENTS SHOWN FOR REFERENCE.
SEE SPECIFIC DISCIPLINE SHEETS FOR SPECIFIC INFORMATION.
REINSTALL AND REFINISH 1X6 BOARD CEILING WITH 1/2" SPACE BETWEEN.
SURFACE ATTACHED TO <N> PLYWOOD SUBSTRATE TO MATCH <E>
ATTACHMENT SIZE, FINISH CADENCE AND PATTERN. ASSUME 5% <N>
REPLACEMENT BOARDS TO MATCH <E> IN SPECIES, GRADE, SIZE, AND FINISH
INSTALL <N> CEILING TILE WITHIN <N> HUNG TRACK SYSTEM.
COORDINATE WITH MECH, ELEC, TECH, AND FIRE PROTECTION
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
REFER TO SHEET G005 FOR CEILING TYPES.
PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT FINISH.
ALL FIRE SUPPRESSION PIPING CONCEALED WITHIN ATTIC TO BE BLACK STEEL.
COORDINATE WITH STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, TECHNOLOGY, FIRE
SUPPRESSION, AND FIRE ALARM DRAWINGS FOR LOCATIONS OF CEILING FIXTURES. GC TO PROVIDE CONSOLIDATED SHOP DRAWINGS OF ALL SYSTEMS, AND PROVIDE REQUIRED MOCK UPS AND SAMPLES.
GC TO MINIMIZE…