This is a comprehensive technical specifications document for exhibit planning, design, and fabrication services under an Indefinite Delivery, Indefinite Quantity (IDIQ) contract with the National Park Service, along with supporting environmental testing reports and photographs for the Kawuneeche Visitor Center rehabilitation project at Rocky Mountain National Park.
The specifications document establishes the standard processes, deliverables, and requirements for exhibit development across six major phases: Pre-Design, Schematic Design, Design Development, Production Design, Production Support, and Production/Fabrication. The Pre-Design phase includes site orientation, resource identification, exhibit planning workshops, and development of a Project Brief with Class C production cost estimates. Schematic Design requires development of three design alternatives with bubble diagrams, preliminary sketches, and Class B cost estimates, culminating in selection of a preferred design. Design Development is organized into three sub-phases (DD1, DD2, DD3) that progressively develop graphic layouts, text, material selections, electronic programs, audio description plans, and content management databases, with formative evaluation as required. Production Design (PD1 and PD2) finalizes all drawings, specifications, and production-ready files that become government property. The document specifies detailed requirements for accessibility compliance with ABAAS and Rehabilitation Act standards, universal design principles, audio description for visual content, and open captioning for audiovisual programs. Production-quality deliverables include comprehensive exhibit design drawings, graphic layouts with professional typography, material/color/finish samples, electronic equipment specifications, audio description production plans, and content management database reports. The contract establishes a project management structure with designated Base Contract and Task Order Project Managers responsible for quality control, schedule tracking, submittal coordination, and monthly status reporting to the Contracting Officer's Representative (COR).
The supporting environmental documentation includes asbestos analysis testing from EMLab P&K dated October 9, 2017, which identified asbestos content exceeding 1% in six of 26 samples analyzed from the Kawuneeche Visitor Center, specifically chrysotile asbestos in floor tile and mastic samples (3-7% concentration) and joint compound/texture samples (2% concentration). Lead paint testing by Reservoirs Environmental identified lead concentrations above the reporting limit (0.069-0.083%) in four exterior paint samples from the main building and detached bathroom building, all from circa 1963 construction era components. Lead in soil testing showed 13.4 mg/kg concentration. The photographs document various building materials sampled including baseboard adhesive, composite drywall/joint compound, duct sealant, flooring mastic, floor tile and mastic, insulation board, lay-in ceiling panels, asphaltic roofing material, textured wall surfacing, and sink pan undercoating across multiple locations within the visitor center facility dated October 6, 2017.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Approved by:
Approved Signatory Noah Lazarte
Report for:
Brandy Howard, CIH Landmark Environmental, Inc.
7881 Shaffer Parkway Littleton, CO 80127
Regarding: Project: 17075.001.001; Moraine Park Discovery Ctr. RMNP
EML ID: 1808578
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 10-09-2017
Service SOPs: Asbestos PLM (EPA Methods 600/R-93/116 & 600/M4-82-020, SOP EM-AS-S-1267)
EMLab ID: 1808578, Page 1 of 10EMLab P&K, LLC
EMLab P&K 4955 Yarrow Street , Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Total Samples Submitted: 26 Total Samples Analyzed: 26
Total Samples with Layer Asbestos Content > 1%: 6
Location: SVC-C-M3-BBA01-01, Baseboard Adhesive Lab ID-Version‡: 8463407-1
Sample Layers Asbestos Content Off-White Baseboard ND
Yellow Mastic ND White Compound ND
Sample Composite Homogeneity: Poor
Location: SVC-109-CDW01-01, Composite Drywall / Joint Compound Lab ID-Version‡: 8463408-1
Sample Layers Asbestos Content Pink Drywall with Brown Paper and Paint ND
Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
Location: SVC-122-CDW01-02, Composite Drywall / Joint Compound Lab ID-Version‡: 8463409-1
Sample Layers Asbestos Content Pink Drywall with Brown Paper ND
Off-White Joint Compound 2% Chrysotile Cream Tape ND
Off-White Texture with Paint < 1% Chrysotile Composite Asbestos Fibrous Content: < 1% Asbestos
Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.
EMLab ID: 1808578, Page 2 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Location: SVC-M3-CDW02-01, Composite Drywall / Joint Compound Lab ID-Version‡: 8463410-1
Sample Layers Asbestos Content Pink Drywall with Brown Paper ND
Off-White Joint Compound ND Cream Tape ND
Off-White Texture with Paint ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
EMLab ID: 1808578, Page 3 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Location: SVC-B1-CDW02-02, Composite Drywall / Joint Compound Lab ID-Version‡: 8463411-1
Sample Layers Asbestos Content Pink Drywall with Brown Paper ND
Off-White Joint Compound ND Cream Tape ND
Off-White Texture with Paint ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Location: SVC-B-102-CDW03-01, Composite Drywall / Joint Compound Lab ID-Version‡: 8463412-1
Sample Layers Asbestos Content Pink Drywall with Brown Paper ND
Off-White Joint Compound ND Cream Tape ND
Off-White Texture with Paint ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Location: SVC-B-106-CDW03-02, Composite Drywall / Joint Compound Lab ID-Version‡: 8463413-1
Sample Layers Asbestos Content Pink Drywall with Brown Paper ND
Off-White Joint Compound ND Cream Tape ND
Off-White Texture with Paint ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
EMLab ID: 1808578, Page 4 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Location: SVC-A-113-CDW04-01, Composite Drywall / Joint Compound Lab ID-Version‡: 8463414-1
Sample Layers Asbestos Content Pink Drywall with Brown Paper ND
Off-White Joint Compound 2% Chrysotile Cream Tape ND
Off-White Compound with Paint < 1% Chrysotile White Texture with Paint ND
Composite Asbestos Fibrous Content: < 1% Asbestos Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.
EMLab ID: 1808578, Page 5 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Location: SVC-A-114-CDW04-02, Composite Drywall / Joint Compound Lab ID-Version‡: 8463415-1
Sample Layers Asbestos Content Pink Drywall with Brown Paper ND
Off-White Joint Compound 2% Chrysotile Cream Tape ND
Off-White Compound with Paint 2% Chrysotile White Texture with Paint ND
Composite Asbestos Fibrous Content: < 1% Asbestos Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.
Location: SVC-C-AT-DS01-01, Duct Sealant Lab ID-Version‡: 8463416-1
Sample Layers Asbestos Content Semi-Transparent Sealant ND
Sample Composite Homogeneity: Good
Location: SVC-A-101-FM01-01, Flooring Mastic Lab ID-Version‡: 8463417-1
Sample Layers Asbestos Content Yellow Mastic ND
Gray Leveling Compound ND Sample Composite Homogeneity: Moderate
Location: SVC-B-102-FM02-01, Flooring Mastic Lab ID-Version‡: 8463418-1
Sample Layers Asbestos Content Yellow Mastic ND
Composite Non-Asbestos Content: 5% Synthetic Fibers Sample Composite Homogeneity: Good
EMLab ID: 1808578, Page 6 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Location: SVC-A-109-FTC01-01, Floor Tile and Mastic Lab ID-Version‡: 8463419-1
Sample Layers Asbestos Content Gray Floor Tile 3% Chrysotile Black Mastic 3% Chrysotile
Sample Composite Homogeneity: Moderate
Location: SVC-A-122-FTC01-02, Floor Tile and Mastic Lab ID-Version‡: 8463420-1
Sample Layers Asbestos Content Gray Floor Tile 3% Chrysotile
Black/Yellow Mastic 7% Chrysotile Sample Composite Homogeneity: Moderate
Location: SVC-B-106-FTC02-01, Floor Tile and Mastic Lab ID-Version‡: 8463421-1
Sample Layers Asbestos Content Red Floor Tile ND
Black/Yellow Mastic ND Sample Composite Homogeneity: Moderate
Location: SVC-A-112-IB01-01, Insulation Board with Sealant Lab ID-Version‡: 8463422-1
Sample Layers Asbestos Content Yellow Insulation with Coating ND
Composite Non-Asbestos Content: 80% Glass Fibers 10% Cellulose
Sample Composite Homogeneity: Moderate
EMLab ID: 1808578, Page 7 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Location: SVC-A-112-IB01-02, Insulation Board with Sealant Lab ID-Version‡: 8463423-1
Sample Layers Asbestos Content Yellow Insulation with Coating ND
Composite Non-Asbestos Content: 60% Glass Fibers 25% Cellulose
Sample Composite Homogeneity: Moderate
Location: SVC-B-103-LIP01-01, Lay-In Ceiling Panel Lab ID-Version‡: 8463424-1
Sample Layers Asbestos Content Gray Ceiling Tile with Foil ND
Composite Non-Asbestos Content: 60% Glass Fibers 5% Cellulose
Sample Composite Homogeneity: Good
Location: SVC-C-AT-RM01-01, Asphaltic Roofing Material Lab ID-Version‡: 8463425-1
Sample Layers Asbestos Content Brown Fiberboard ND
Black Roofing Shingle with Tan Pebbles ND Composite Non-Asbestos Content: 50% Cellulose Sample Composite Homogeneity: Poor
Location: SVC-A-113-TS01-01, Texture Wall Surfacing Lab ID-Version‡: 8463426-1
Sample Layers Asbestos Content White Texture with Paint ND
Sample Composite Homogeneity: Good
EMLab ID: 1808578, Page 8 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Location: SVC-A-113-TS01-02, Texture Wall Surfacing Lab ID-Version‡: 8463427-1
Sample Layers Asbestos Content White Texture with Paint ND
Sample Composite Homogeneity: Good
Location: SVC-A-113-TS01-03, Texture Wall Surfacing Lab ID-Version‡: 8463428-1
Sample Layers Asbestos Content Off-White Compound with Paint 2% Chrysotile
White Texture with Paint ND Sample Composite Homogeneity: Moderate
Location: SVC-A-113-TS02-01, Texture Wall Surfacing Lab ID-Version‡: 8463429-1
Sample Layers Asbestos Content Off-White Compound with Paint < 1% Chrysotile
White Texture with Paint ND Sample Composite Homogeneity: Moderate
Location: SVC-A-113-TS02-02, Texture Wall Surfacing Lab ID-Version‡: 8463430-1
Sample Layers Asbestos Content White Texture with Paint ND
Sample Composite Homogeneity: Good
EMLab ID: 1808578, Page 9 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.
C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.
RMNP
Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Location: SVC-A-113-TS02-03, Texture Wall Surfacing Lab ID-Version‡: 8463431-1
Sample Layers Asbestos Content White Texture with Paint ND
Sample Composite Homogeneity: Good
Location: SVC-A-110-UC01-01, Undercoating on Sink Pan Lab ID-Version‡: 8463432-1
Sample Layers Asbestos Content Gray Sink Undercoating ND
Sample Composite Homogeneity: Good
EMLab ID: 1808578, Page 10 of 10EMLab P&K, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Fog Rain Snow Wind Clear www.EMLabPK.com
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
SVC-C-AT-RM01-01 Asphaltic Roofing Material B ND N/A N/A
SVC-B-103-LIP01-01 Lay-in Ceiling Panel B ND N/A N/A
SVC-A-112-IB01-02 Insulation Board with Sealant B ND N/A N/A
SVC-A-112-IB01-01 Insulation Board with Sealant B ND N/A N/A
SVC-B-106-FTC02-01 Floor Tile and Mastic B ND N/A N/A
SVC-A-122-FTC01-02 Floor Tile and Mastic B ND N/A N/A
SVC-A-109-FTC01-01 Floor Tile and Mastic B ND N/A N/A
SVC-B-102-FM02-01 Flooring Mastic B ND N/A N/A
SVC-A-101-FM01-01 Flooring Mastic B ND N/A N/A
SVC-C-AT-DS01-01 Duct Sealant B ND N/A N/A
N/A N/A
SVC-A-114-CDW04-02 Composite Drywall / Joint Compound B ND N/A N/A
B ND N/A N/A
SVC-B-106-CDW03-02 Composite Drywall / Joint Compound B ND N/A N/A
N/A N/A
SVC-C-B1-CDW02-02 Composite Drywall / Joint Compound B ND N/A N/A
N/A N/A
SVC-A-122-CDW01-02 Composite Drywall / Joint Compound B ND N/A N/A
Textured Wall Surfacing
Undercoating on Sink Pan
Baseboard Adhesive
Textured Wall Surfacing
Textured Wall Surfacing
Textured Wall Surfacing
Textured Wall Surfacing
Textured Wall Surfacing
Composite Drywall / Joint Compound
Composite Drywall / Joint Compound
Composite Drywall / Joint Compound
Composite Drywall / Joint Compound
SVC-A-113-TS02-03
SVC-A-110-UC01-01
SVC-C-M3-BBA01-01
SVC-A-113-TS01-01
SVC-A-113-TS01-02
SVC-A-114-TS01-03
SVC-A-114-TS02-01
SVC-A-114-TS02-02
SVC-A-109-CDW01-01
SVC-C-M3-CDW02-01
SVC-B-102-CDW03-01
SVC-A-113-CDW04-01
By submitting this Chain of Custody, you agree to be bound by the terms and conditions set forth at www.emlabpk.com/terms.html Copyright © 2002-2009 EMLab P&K
Company: Landmark Environmental
Contact: Brandy Howard
Phone/Email:720-878-6475
7881 Shaffer PKWY, Littleton, CO 80127 Special Instructions:Email results to bhoward@landmarkenviro.com
BC - BioCassette™ ST - Spore Trap: Zefon, Allergenco, Burkard…
T - Tape D - Dust
A1S - Andersen SW - Swa SO - Soil
NP - Non-Potable Water O - Other:
SAS - Surface Air Sam P - Potable Water B - Bulk
CP - Contact Plate
N/A N/A
SAMPLE TYPE CODES RELINQUISHED BY DATE & TIME
B ND
N/A
N/A N/A
N/A N/A
N/A
N/A N/AB ND
B ND
B ND
B ND
B ND
N/A N/AB ND
B ND
B ND
B ND
B
N/A N/A
ND
N/A N/A
N/A N/AB
N/A N/A
N/A N/A
N/A N/A
ND
B ND
B ND
B ND
-M e d ia
S u rf a ce F u n g i (
G e n u s
ID
A sp sp p.
PROJECT INFORMATION
Sample
Type
(Below
TAT
(Abov e)
Total
Volume/Area
(as Sample ID Description
PO Number: WH - Weekend/Holiday
CONTACT INFORMATION
Project Desc.:Moraine Park Discovery Ctr. RMNP
P
C R p le a se s p e ci fy t e st
G ra m
S ta in a n d
C o u n ts
C u ltu ra b le
A ir a n d S u rf a ce
B a ct e ri a
Le gi on el la c ul tu re
T o ta l C o lif o rm E
.c ol i (P re se nc e/
A bs en ce
M e m b ra n e F ilt ra tio n
P le a se s p e ci fy o rg a n is m e d ia
S u rf a ce F u n g i (
G e n u s
ID
A sp sp p.
None
Marlton, NJ: 3000 Lincoln Drive East,Suite A Marlton, NJ 08053 (866) 871-1984 Phoenix, AZ: 1501 West Knudsen Drive, Phoenix, AZ 85027 * (800) 651-4802 S. San Francisco, CA: 6000 Shorline Ct. Ste 203, S. San Francisco, CA 94080 * (866) 888-6653
TURN AROUND TIME CODES - (TAT)
Project ID:17075.001.001 STD - Standard (DEFAULT) Rushes received after 2pm or on weekends, will be considered received the next business day.
Please alert us in advance of weekend analysis needs.
ND - Next Business Day Project Zip Code:
Sampling9-27-2017/ 0930 Date & Time: SD - Same Business Day Rush
Q u a n tiT ra y
S e w a g e S cr e n e d ia
S u rf a ce F u n g i (
G e n u s
ID
A sp sp p.
CHAIN OF CUSTODY WEATHER
Light Non-Culturable
L E
V E
L
NOTES
(Time of day, Temp, RH, etc.)
Culturable
REQUESTED SERVICES ( Boxes)
Other Requests
Moderate Spore Trap
Tape Swab Bulk
BioCassette ™, Andersen, SAS, Swab, Water, Bulk, Dust, Soil, Heavy
S p o re T ra p
A n a ly si s
O th e r p a rt ic le s
RECEIVED BY DATE & TIME
A sb e st o s A n a ly si s
P C
M A ir bo rn e
F ib er C ou nt
N
IO
S
H
A sb e st o s A n a ly si s
P L
M
E P
A m e th o d
/R
-9
-1
M
P N
B a ct e ri a
P le a se s p e ci fy o rg a n is
C ltu ra b le A ir F u n g i (
G e n u s
ID
A sp sp p.
F n g i -
S p o re
T ra p A n a ly si s
D ir e ct M ic ro sc o p ic
E xa m
Q u a lit a tiv
Q a n tit a tiv e S p o re C o u n t
D ir e ct
E xa
Doc. # 200176 Rev: 24 Revised: 6/29/09 Page 1 of 1, QAD
Attachment B
LEAD CONTAINING PAINT SAMPLE INFORMATION & ANALYTICAL RESULTS
Landmark Environmental, Inc. Lead Paint Inspection Form 7881 Shaffer Parkway Littleton, Colorado 80127 720-283-8975 Fax: 720-283-8666
Client: Anderson Hallas Architects
NPS Contract
Project: 17075.001.001
Kawuneeche Visitor Center
Date: 10/4/17
Inspector: Tristan Fitzpatrick
Sample # Location Component Substrate Color Condition Result
RES 391516
SVC-A-117-LBP01
South wall at west of door, 4’ up. Main
Building, ~1963 Construction Era Wall Drywall White Good BRL
SVC-B-102-LIP02
North wall at 103 door, 1’ up. Visitors Center
Addition, ~1989 Construction Era Wall Wood Army Green Good BRL
SVC-B-105-LIP03
South wall at east of entry door. Visitors
Center Addition, ~1989 Construction Era Wall Drywall White Good BRL
SVC-B-105-LIP04
Half wall in room, on trim board. Visitors
Center Addition, ~1989 Construction Era Trim Wood Brown Good BRL
SVC-B-EXT-LBP05
At south-west corner, exterior of room 103.
Visitors Center Addition, ~1989 Construction
Era Exterior Wall Wood
Dark
Green/Brown Good BRL
SVC-B- EXT-LBP06
At south-west corner, exterior of room 103.
Visitors Center Addition, ~1989 Construction
Era Exterior Trim Wood
Light
Green/Grey Good BRL
SVC-A-EXT-LBP07
At south-east corner, exterior of room 121.
Main Building, ~1963 Construction Era Exterior Wall Wood
Dark
Green/Brown Good 0.070 %
SVC-A-EXT-LBP08
At south-east corner, exterior of room 121.
Main Building, ~1963 Construction Era Exterior Trim Wood
Light
Green/Grey Good 0.076 %
SVC-C-EXT-LBP09
At south west corner, exterior of room B1.
Detached Bathroom / Comfort Building, ~1963 Construction Era Exterior Wall Wood
Dark
Green/Brown Good 0.069 %
SVC-C-EXT-LBP10
At south west corner, exterior of room B1.
Detached Bathroom / Comfort Building, ~1963 Construction Era Exterior Trim Wood
Light
Green/Grey Good 0.083 %
BRL – Below Reporting Limit at the laboratory
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2016
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 391516-1 Project # / PO #: 17075.001.001 Project Description:
RES 391516-1
Sincerely, Jeanne Spencer
President
October 9, 2017
Dear Customer, Reservoirs has analyzed the following sample(s) using Atomic Absorption Spectroscopy (AAS) / Atomic Emission
Spectroscopy - Mass Spectrometry (ICP-MS) per your request. Reported sample results were not blank corrected. The analysis has been completed in general accordance with the appropriate methodology as stated in the analysis table.
Results have been sent to your office.
property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those authorized by the client. The results described in this report only apply to the samples analyzed. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you should have any questions about this report, please feel free to call me at 303-964-1986.
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and
Environmental matrices by the American Industrial Hygiene Association, Lab ID 101533 - Accreditation Certificate #480.
The laboratory is currently proficient in both IHPAT & ELPAT programs respectively.
is the job number assigned to this study. This report is considered highly confidential and the sole
Kawuneeche Visitors Center
Littleton CO 80217
7881 Shaffer Parkway
Tristan Fitzpatrick
Landmark Environmental, Inc.
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
1-866-RESI-ENV
www.reilab.com
Effective January 1, 2016
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
Client Lab Reporting LEAD
ID Number ID Number Limit CONCENTRATION
SVC-A-117-LBP01 EM 1967186 0.0092 BRL
SVC-B-102-LBP02 EM 1967187 0.0082 BRL
SVC-B-105-LBP03 EM 1967188 0.0055 BRL
SVC-B-105-LBP04 EM 1967189 0.020 BRL
SVC-B-EXT-LBP05 EM 1967190 0.0059 BRL
SVC-B-EXT-LBP06 EM 1967191 0.0030 BRL
SVC-A-EXT-LBP07 EM 1967192 0.0034 0.070
SVC-A-EXT-LBP08 EM 1967193 0.0048 0.076
SVC-C-EXT-LBP09 EM 1967194 0.0054 0.069
SVC-C-EXT-LBP10 EM 1967195 0.0074 0.083
Analyst / Data QA:________________________
24 Hour
RESERVOIRS ENVIRONMENTAL, INC.
5801 Logan St., Suite 100
Denver CO 80216
TABLE ANALYSIS: LEAD IN PAINT
RES 391516-1
October 9, 2017
* Unless otherwise noted all quality control samples performed within specifications established by the laboratory.
Landmark Environmental, Inc.
17075.001.001 Kawuneeche Visitors Center October 6, 2017
USEPA SW846 3050B / AA (7420)
BRL = Below Reporting Limit
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Effective January 1, 2016
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 391517-1 Project # / PO #: 17075.001.001 Project Description:
RES 391517-1
Sincerely, Jeanne Spencer
President
October 9, 2017
Dear Customer, Reservoirs has analyzed the following sample(s) using Atomic Absorption Spectroscopy (AAS) / Atomic Emission
Spectroscopy - Mass Spectrometry (ICP-MS) per your request. Reported sample results were not blank corrected. The analysis has been completed in general accordance with the appropriate methodology as stated in the analysis table.
Results have been sent to your office.
property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those authorized by the client. The results described in this report only apply to the samples analyzed. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you should have any questions about this report, please feel free to call me at 303-964-1986.
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and
Environmental matrices by the American Industrial Hygiene Association, Lab ID 101533 - Accreditation Certificate #480.
The laboratory is currently proficient in both IHPAT & ELPAT programs respectively.
is the job number assigned to this study. This report is considered highly confidential and the sole
Kawuneeche Visitors Center
Littleton CO 80217
7881 Shaffer Parkway
Brandy
Landmark Environmental, Inc.
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Effective January 1, 2016
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
Client Lab Reporting LEAD
ID Number ID Number Limit CONCENTRATION (mg/kg) (mg/kg)
SVC-EX-SOIL EM 1967185 13.4 13.4
Analyst / Data QA:________________________
24 Hour
RESERVOIRS ENVIRONMENTAL, INC.
5801 Logan St., Suite 100
Denver CO 80216
TABLE ANALYSIS: LEAD IN SOIL
RES 391517-1
October 9, 2017
* Unless otherwise noted all quality control samples performed within specifications established by the laboratory.
Landmark Environmental, Inc.
17075.001.001 Kawuneeche Visitors Center October 6, 2017
USEPA SW846 3050B / AA (7420)
BRL = Below Reporting Limit
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Attachment C
PHOTOGRAPHS
LANDMARK
Project No.
17075.001.001
Description BBA01 Photo 1
Site Name Kawuneeche Visitors Center Photo Date
10/06/2017
17075.001.001
Description CDW01 Photo 2
Site Name Kawuneeche Visitors Center
17075.001.001
Description CDW02 Photo 3
Site Name Kawuneeche Visitors Center
17075.001.001
Description CDW03 Photo 4
Site Name Kawuneeche Visitors Center
17075.001.001
Description CDW04 Photo 5
Site Name Kawuneeche Visitors Center
17075.001.001
Description DS01 Photo 6
Site Name Kawuneeche Visitors Center
17075.001.001
Description FM01 Photo 7
Site Name Kawuneeche Visitors Center
17075.001.001
Description FM02 Photo 8
Site Name Kawuneeche Visitors Center
17075.001.001
Description FTC01 Photo 9
Site Name Kawuneeche Visitors Center
17075.001.001
Description FTC02 Photo 10
Site Name Kawuneeche Visitors Center
17075.001.001
Description IB01 Photo 11
Site Name Kawuneeche Visitors Center
17075.001.001
Description LIP01 Photo 12
Site Name Kawuneeche Visitors Center
17075.001.001
Description RM01 Photo 13
Site Name Kawuneeche Visitors Center
17075.001.001
Description TS01 Photo 14
Site Name Kawuneeche Visitors Center
17075.001.001
Description TS02 Photo 15
Site Name Kawuneeche Visitors Center
17075.001.001
Description UC01 Photo 16
Site Name Kawuneeche Visitors Center
National Park Service | Harpers Ferry Center
Exhibit Planning, Design, and Fabrication Specifications ATTACHMENT 1 - IDIQ Exhibit Planning & Design Contract
April 2020
Contents
1. Definitions 3
2. Project Management 12
3. Exhibit Planning, Design, and Fabrication Process 15
4. Travel, Meetings, and Presentations 32
5. Submittals and Reviews 37
6. Accessibility 39
7. Exhibit Evaluation 42
8. Production Cost Estimates 45
9. Exhibit Visualization 50
10. Resource Packages 52
11. Content Management 54
12. Text 60
13. Exhibit Drawings 65
14. Materials, Colors, and Finishes 72
15. Two-Dimensional Exhibit Graphics 76
16. Content Specialties 99
17. Use Rights and Licenses 111
18. Object Preservation and Protection 113
19. Electronic Programs 122
20. Electronic Equipment 127
21. Tactile Exhibit Elements and Mechanical Interactives 139
22. Design Guidelines for Exhibit Structures 144
23. Exhibit Lighting 146
24. Mock-Ups and Prototypes 150
25. Planning & Design Support During Fabrication 152
26. Maps 155
27. Quality Standards and Safety for Fabrication 160
28. Shop Inspections and Installation 166
29. Operational Training and References 173
30. Closeout 181
31. Audio Description 186
1. Definitions
ABAAS: Architectural Barriers Act Accessibility Standards are the accessibility standards which per-tain to the Federal sector. The ABA, or Architectural Barriers Act of 1968, requires access to facilities designed, built, altered, or leased with federal funds. (See also “Accessible,” “ADA,” and “Rehabilita-tion Act.”)
Accessible: In context with the requirements of this contract, accessible is defined as in compliance with accessibility standards as specified in the Programmatic Accessibility Guidelines for National Park Service Interpretive Media. Federal laws, including the Architectural Barriers Act Accessibility Standards (ABAAS) and Sections 504 and 508 of the Rehabilitation Act, shall be followed. Universal Design and its seven principles shall be applied as a part of the NPS definition and requirements.
Accessioned Objects (AO): Objects accessioned into the park collection, or objects on loan from other institutions. These items require the highest level of preservation and security criteria. Historic objects also include original period items acquired as part of the exhibit project to enhance interpre-tation. Park staff determines whether to accession these objects on a case by case basis.
ADA: Americans with Disabilities Act of 1990. This law prohibits discrimination against individuals on the basis of disability. It applies to state and local governments, and public accommodations oper-ated by the private sector. While there are exceptions, it does not generally apply to media and exhibi-tions that are federally funded and installed in federal facilities. Therefore, the term “ADA” or “ADA compliant” should not be used when referring to accessibility compliance in Federal Government owned and operated facilities. (See also “ABAAS” and “Rehabilitation Act.”)
Artifacts: See “Accessioned Objects.”
As-Built AV Drawings: Final design and detail drawings updated by the contractor to reflect all changes that occur during installation and provide a record of the “as-built” condition of the AV, or Electronic Equipment, systems. Drawings include all equipment, cables, connectors, connections points, and devices.
As-Built Exhibit Plan: The fabrication contractor updates exhibition content data (e.g., text, con-tent schedules, technical data, etc.) to reflect all changes that occur during fabrication and installation, and provides a record of the “as-built” condition of the exhibits, which may vary from the final design documents prepared by the exhibit planning & design contractor.
As-Built Exhibit Drawings: Final design and detail drawings updated by the fabrication contrac-tor to reflect all changes that occur during fabrication and installation and provide a record of the “as-built” condition of the exhibits, which may vary from the final design documents prepared by the exhibit planning & design contractor.
As-Built Lighting Plan: A final plan drawing for the installed exhibit lighting system showing fix-ture placement, focusing information, and itemized lists detailing fixture, accessory, and lamp data.
Assistive Listening Systems: Assistive listening is used by persons with mild to profound hearing loss who may or may not use a hearing aid. These systems are a suite of equipment used to deliver sound directly from its source to the person receiving it. The receiving person can also amplify the sound based on their needs. The amplified sound is transmitted via radio frequency or infrared to a receiver connected to the person’s headset, ear buds, or an induction loop that transmits the sound to the person’s hearing aid.
Audience-Centered Experience (ACE): Audience Centered Experiences are the practice of elicit-ing participation and contribution from an audience and community.
Audience-centered interpretation can infuse any and all park experiences by providing opportunities for audience members to contribute to the meaning-making process, engage with each other, and
April, 2020
Definitions | 3
National Park Service | Standard Exhibit Planning, Design, and Fabrication Specifications
4 | Definitions explore the current social context of national park resources.
AV Program Concept Treatment: A narrative overview of the proposed production’s creative approach and storyline prepared during the exhibit planning and design process. AV Concept Treat-ments typically include a description of the actors and/or participants, their roles and general dia-logue or narration, and a general description of the scenes, locations, graphics, artwork, and anima-tion to be used in the production with sufficient detail to provide a sense of the proposed production;
the basis of the production plan and script.
Audio Description (AD): Through words, AD describes visual content essential for understanding the content of a program. Audio description is used for a variety of media, including video, digital interactive programs and exhibits. People who are blind or have low vision are the primary audience, but audio description can also be used by people who have print disabilities or auditory learning styles. AD is typically scripted and recorded by a professional. In some cases, AD text may be read by a screen reader and synthesized voice. Specific delivery systems and techniques vary based on the media and venue. AD is also referred to as video description, verbal description, descriptive video and descriptive audio.
AV Program Production Plan: A document which presents the major categories of work to be performed in the planning, production, and post-production phases of the program. The Production Plan shall describe all of the elements required to produce the program as outlined in the Treatment and/or Scope of Work, including, but not limited to: production personnel (including the use and identification of sub-contractors, consultants, and other salaried employees of the firm), equipment, post-production facilities, travel, transportation, and a cost estimate of all materials expenses such as capture and storage media, and archival images. Within the Production Plan, the contractor shall con-firm that they understand the “Rights in Data—Special Works” requirements of the contract, includ-ing rights for music, stock footage, and other elements.
AV Program Production Treatment: A narrative description of the proposed production ele-ments to include an estimated percentage of the program that will be comprised of original, archival, or stock materials (including footage, photographs, or audio); reenactments; interviews; animation;
graphics; and illustrations; and the proposed source(s) for such materials. It shall also include a description of the narration, sound effects, and musical score, to include whether the score shall be comprised of original or stock music. The AV Production Treatment provides the basis of the AV Pro-duction Plan and script.
Audiovisual (AV) program: One type of Electronic Program (EP). AV programs include linear programs with fixed running times. Through the use and/or integration of numerous elements such as sound effects, music, voice-overs, interviews, moving and historic images, AV programs can be innate-ly dynamic. They are especially effective in eliciting emotional responses, telling stories, and conveying concepts where motion and/or sound are important or particularly effective. Throughout these spec-ifications “AV” is also used an as umbrella term to refer collectively to Audiovisual Programs, Digital Interactive Programs, and Electromechanical Programs.
Bubble Diagrams: Diagrams that use labeled shapes (bubbles) identifying exhibit themes and con-cepts to show how they relate to each other and/or to their location on the exhibit floor plan.
Captions: Captions are designed for persons who are deaf or have hearing loss. The terms “cap-tions” and “Subtitles for the Deaf and Hard of Hearing” (SDH) are used interchangeably in these specifications. They display spoken dialogue and non-speech information as printed words on tele-vision screens, computer monitors, projection screens, caption boards and other visual displays.
Non-speech information is audible information essential to understanding the content. Examples of non-speech information include speaker identification, sound effects, music, manner of speaking (whispering, word emphasis, emotion, etc.) and audience reactions (laughing, booing, etc.) Captions may hold secondary benefits for people who are learning a foreign language, learning how to read, Definitions | 5 watching a program in a noisy area, or understand best by processing visual information. While used as a catch-all term, different types of “captions” have their own unique technical production, pro-gramming, coding, playback, and/or decoding processes. Captions are either closed or open:
Closed Captions (CC): Closed captions do not appear on screen unless the viewer has selected them to appear. They require decoding technology. Closed captions are generally produced for online videos and DVD/BluRay discs. Closed captions shall not be used for audiovisual programs shown in NPS venues.
Open Captions (OC): Open captions are displayed on the screen at all times automatically as part of the video. There is no option to turn the captions on or off. They are “burned” into the picture. All audiovisual programs shown within NPS venues must display captions on-screen at all times. For NPS productions requiring open captions, contractors shall use a pro-duction process which allows control of font selection, size, color, edging, and other design parameters.
Charette: A meeting to brainstorm and fully explore all possible design directions for presentation and communication of content in the exhibition. Differs from the Exhibit Planning Workshop in that it is more focused on design solutions.
Class A Production Cost Estimate: Detailed cost estimate which includes an itemized break-down, at a minimum, of labor hours and rates, material costs, shipping, and travel, based on specifica-tions for all exhibit elements found in the Production Documents.
Class B Production Cost Estimate: An intermediate level cost estimate based on allocating an overall cost for each exhibit Scene or Content Group in the exhibition plan, and including allowances for all high-cost exhibit elements currently identified, contingency, shipping, and installation. Class B Production Cost Allowances/Estimates are used during the Schematic and Design Development phases of work, and become increasingly detailed as the design progresses.
Class C Production Cost Estimate: An initial cost estimate based on the cost of the exhibition per square foot. Class C estimates are used during the Pre-Design phase of work.
Closed Captions: See “Captions”
Comprehensive Exhibit Plan: A report from a Content Management Database that includes a comprehensive list of all exhibit elements, including AOs, CAs, CEs, EEs, EPs, GLs, IMs, and LAs.
Content Development: See Exhibit Planning.
Content Group: A discrete thematic story or information set within an exhibition that, together with adjacent related Content Groups, is part of a larger Scene. A Content Group tells one aspect of the larger story or information presented in the overall Scene.
Content Management: A system to organize and track all media elements to be featured in the exhibition, organized by unique exhibit element number.
Content Management Numbering System: A system that identifies each exhibit element with a unique number (the Element Identification Number) made up of three parts, separated by hyphens, as follows: Element Type - Scene - Content Group Number - Item Number. For example, IM-02-04-
Content Specialties: Any exhibit element that requires detailed subject matter, creative, technical, and/or artistic input to inform and direct its production by a creative or technical specialist. These elements include, but are not limited to, original artwork, sculptures, models, reproductions, objects, dioramas, life-sized figures, and electronic programs.
Content Specialties Reference Package: A document consisting of written descriptions and graphic depictions that together provide the background information and design intent needed for
6 | Definitions an artist, craftsman, or technical specialist to produce a custom element. Prepared during the Design Development and Production Design phases of exhibit planning and design.
Contracting Officer’s Representative (COR): For Federal Government contracts, an authorized representative of the Contracting Officer responsible for monitoring the quality and performance of work performed under individual contracts.
Custom Element (CE): General category for three-dimensional content in an exhibition that is not otherwise categorized. Custom Elements may be commercially available items, but more often are specifically created for the exhibition, requiring creative design, and/or artistic development and execution. Examples include sculptures, architectural models, natural history models, reproduction historic objects, dioramas, manipulatives, electrical and mechanical interactive devices, mannequins, and topographic maps. Custom Elements are tracked in the Content Management Numbering Sys-tem, and are inventoried in FMSS where they are designated as “Custom Three-Dimensional Exhibit Elements.”
Custom Three-Dimensional Exhibit Element: Term used for FMSS inventory. See Custom Element.
Design Alternatives: Distinct approaches to the exhibit content, its organization and presentation in the given exhibition space. Multiple Design Alternatives (usually three) are developed in the Sche-matic Design 1 phase of work as part of the process used to arrive at a Preferred Design Alternative.
Design Development: The phase of the exhibit development process in which all major content and design details of the project are completed. Technical details required for Production are not included in this phase of work.
Digital Interactive program: One type of Electronic Program (EP), which is often non-linear.
These programs encourage users to become engaged through interaction, exploration, and learning at their own pace and may include multiple layers of information.
Electromechanical program: One type of Electronic Program (EP). Electromechanical programs include but are not limited to electronic programming such as LED lights within a map, diorama, or other exhibit element; lighting programmed to be synchronous or otherwise function in concert with exhibits or exhibit elements; and motion sensors programmed to trigger lighting, audiovisual, digital interactive, or mechanical exhibit elements.
Electronic Equipment (EE): All electronic and ancillary equipment required to present or support the presentation of Electronic Programs, Assistive Listening, and Audio Description, in an exhibition, including any programmed lighting and electromechanical devices.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .