B09_ROMO_KVC_326235_Final_CD_Specifications_Bid_Revisions_Part2_0005.pdf

PDF 25 MB Posted

Attached to
ROMO 326235 Rehabilitate Kawuneeche Visitor Center
Solicitation number
140P2026R0057
Issued by

About this file

This is a comprehensive technical specifications document for exhibit planning, design, and fabrication services under an Indefinite Delivery, Indefinite Quantity (IDIQ) contract with the National Park Service, along with supporting environmental testing reports and photographs for the Kawuneeche Visitor Center rehabilitation project at Rocky Mountain National Park.

The specifications document establishes the standard processes, deliverables, and requirements for exhibit development across six major phases: Pre-Design, Schematic Design, Design Development, Production Design, Production Support, and Production/Fabrication. The Pre-Design phase includes site orientation, resource identification, exhibit planning workshops, and development of a Project Brief with Class C production cost estimates. Schematic Design requires development of three design alternatives with bubble diagrams, preliminary sketches, and Class B cost estimates, culminating in selection of a preferred design. Design Development is organized into three sub-phases (DD1, DD2, DD3) that progressively develop graphic layouts, text, material selections, electronic programs, audio description plans, and content management databases, with formative evaluation as required. Production Design (PD1 and PD2) finalizes all drawings, specifications, and production-ready files that become government property. The document specifies detailed requirements for accessibility compliance with ABAAS and Rehabilitation Act standards, universal design principles, audio description for visual content, and open captioning for audiovisual programs. Production-quality deliverables include comprehensive exhibit design drawings, graphic layouts with professional typography, material/color/finish samples, electronic equipment specifications, audio description production plans, and content management database reports. The contract establishes a project management structure with designated Base Contract and Task Order Project Managers responsible for quality control, schedule tracking, submittal coordination, and monthly status reporting to the Contracting Officer's Representative (COR).

The supporting environmental documentation includes asbestos analysis testing from EMLab P&K dated October 9, 2017, which identified asbestos content exceeding 1% in six of 26 samples analyzed from the Kawuneeche Visitor Center, specifically chrysotile asbestos in floor tile and mastic samples (3-7% concentration) and joint compound/texture samples (2% concentration). Lead paint testing by Reservoirs Environmental identified lead concentrations above the reporting limit (0.069-0.083%) in four exterior paint samples from the main building and detached bathroom building, all from circa 1963 construction era components. Lead in soil testing showed 13.4 mg/kg concentration. The photographs document various building materials sampled including baseboard adhesive, composite drywall/joint compound, duct sealant, flooring mastic, floor tile and mastic, insulation board, lay-in ceiling panels, asphaltic roofing material, textured wall surfacing, and sink pan undercoating across multiple locations within the visitor center facility dated October 6, 2017.

View the file

Other files

File Type Posted
B09_ROMO_KVC_326235_Final_CD_Specifications_Bid_Revisions_Part3_0005.pdf PDF
B09_ROMO_KVC_326235_Final_CD_Drawing_Set_Bid_Revisions_Part2_0005.pdf PDF
B09_QR_Tracker_ROMO_326235_9_4_26_0005.pdf PDF
Sol_140P2026R0057_Amd_0005.pdf PDF
B09_ROMO_KVC_326235_Final_CD_Drawing_Set_Bid_Revisions_Part3_0005.pdf PDF
B09_ROMO_KVC_326235_Final_CD_Drawing_Set_Bid_Revisions_Part1_0005.pdf PDF
B09_ROMO_KVC_326235_Final_CD_Specifications_Bid_Revisions_Part1_0005.pdf PDF
B09_P2026R0057_SF30_QA_and_Clauses_9_4_26_0005.pdf PDF
B09_ROMO_KVC_326235_Final_CD_Drawing_Set_Bid_Revisions_Part4_0005.pdf PDF
B09_P2026R0057_SF30_QA_and_Clauses_8_26_0004.pdf PDF
Sol_140P2026R0057_Amd_0004.pdf PDF
BaselineScheduleReviewChecklist_Form_10-22-18_v508_0003.docx DOCX document
2nd_Site_Visit_Sign_in_Sheet_0003.pdf PDF
Sol_140P2026R0057_Amd_0003.pdf PDF
B09_P2026R0057_SF30_QA_and_Clauses_8_21_0003.pdf PDF
B09_QR_Tracker_ROMO_326235_0003.pdf PDF
B08_Solit_PSP_Vol_II_Deliverables_LmtOnSubconRpt_REQD_0003.xlsx XLSX spreadsheet
Sol_140P2026R0057_Amd_0002.pdf PDF
B09_P2026R0057_SF30_QA_and_Clauses_8_19_0002.pdf PDF
B09_Attachment_5_Solit_PSP_Vol_I_Exp_REQD_0002.docx DOCX document
Contact_Procedures_Reminder_0002.docx DOCX document
B09_Attachment_6_Solit_PSP_Vol_I_PastPerf_REQD_0002.docx DOCX document
B09_QR_Tracker_ROMO_326235_0002.pdf PDF
B11_PreProposal_Conf_Slides_ROMO_325250_0001.pptx PPTX presentation
B09_Amendment_1_ROMO_KVC_326235_ContractPriceSchedule_Rev_1_8-5-26_0001.xlsx XLSX spreadsheet
B09_P2026R0057_SF30_QA_and_Clauses_8_13_0001.pdf PDF
Sol_140P2026R0057_Amd_0001.pdf PDF
B09_QR_Tracker_ROMO_326235_0001.pdf PDF
ROMO_326235__-_Virtual_PreBid_Conference_Transcription_0001.docx DOCX document
Prebid_sign_in_sheet_0001.pdf PDF
B09_Amendment_1_What_Evaluators_Will_Ask_for_Each_Factor_0001.docx DOCX document
Virtual_sign_in_sheet_0001.pdf PDF
B02_Attatchment_2_26_0330_-_ROMO_KVC_326235_Final_CD_Drawing_Set_Part4.pdf PDF
B02_Attatchment_2_26_0330_-_ROMO_KVC_326235_Final_CD_Drawing_Set_Part1.pdf PDF
B01_Attatchment_1_ROMO_KVC_326235_Final_CD_Specifications_update_Part1.pdf PDF
B08_Attachment_10_ROMO_KVC_326235_CD_ContractPriceSchedule_BLANK.xlsx XLSX spreadsheet
Sol_140P2026R0057.pdf PDF
B08_Attachment_8_Solit_PSP_Vol_II_GenRefs.pdf PDF
B08_Attachment_6_Solit_PSP_Vol_I_PastPerf_REQD.pdf PDF
B08_Attachment_7_Solit_PSP_Vol_II_BidBond.pdf PDF
B02_Attatchment_2_26_0330_-_ROMO_KVC_326235_Final_CD_Drawing_Set_Part2.pdf PDF
B02_Attatchment_2_26_0330_-_ROMO_KVC_326235_Final_CD_Drawing_Set_Part3.pdf PDF
B01_Attatchment_1_ROMO_KVC_326235_Final_CD_Specifications_update_Part2.pdf PDF
B01_Attatchment_1_ROMO_KVC_326235_Final_CD_Specifications_update_Part3.pdf PDF
B08_Attachment_9_Solit_PSP_Vol_II_SubKPlan.pdf PDF
B08_Attachment_5_Solit_PSP_Vol_I_Exp_REQD.pdf PDF
B08_Attachment_3_Wage_Determination.pdf PDF
B08_Attachment_4_Construction_Contract_Administration.pdf PDF
B08_P2026R0057_SF1442_and_Clauses_7_30_26.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Approved by:

Approved Signatory Noah Lazarte

Report for:

Brandy Howard, CIH Landmark Environmental, Inc.

7881 Shaffer Parkway Littleton, CO 80127

Regarding: Project: 17075.001.001; Moraine Park Discovery Ctr. RMNP

EML ID: 1808578

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 10-09-2017

Service SOPs: Asbestos PLM (EPA Methods 600/R-93/116 & 600/M4-82-020, SOP EM-AS-S-1267)

EMLab ID: 1808578, Page 1 of 10EMLab P&K, LLC

EMLab P&K 4955 Yarrow Street , Arvada, CO 80002

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Total Samples Submitted: 26 Total Samples Analyzed: 26

Total Samples with Layer Asbestos Content > 1%: 6

Location: SVC-C-M3-BBA01-01, Baseboard Adhesive Lab ID-Version‡: 8463407-1

Sample Layers Asbestos Content Off-White Baseboard ND

Yellow Mastic ND White Compound ND

Sample Composite Homogeneity: Poor

Location: SVC-109-CDW01-01, Composite Drywall / Joint Compound Lab ID-Version‡: 8463408-1

Sample Layers Asbestos Content Pink Drywall with Brown Paper and Paint ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

Location: SVC-122-CDW01-02, Composite Drywall / Joint Compound Lab ID-Version‡: 8463409-1

Sample Layers Asbestos Content Pink Drywall with Brown Paper ND

Off-White Joint Compound 2% Chrysotile Cream Tape ND

Off-White Texture with Paint < 1% Chrysotile Composite Asbestos Fibrous Content: < 1% Asbestos

Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.

EMLab ID: 1808578, Page 2 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: SVC-M3-CDW02-01, Composite Drywall / Joint Compound Lab ID-Version‡: 8463410-1

Sample Layers Asbestos Content Pink Drywall with Brown Paper ND

Off-White Joint Compound ND Cream Tape ND

Off-White Texture with Paint ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

EMLab ID: 1808578, Page 3 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: SVC-B1-CDW02-02, Composite Drywall / Joint Compound Lab ID-Version‡: 8463411-1

Sample Layers Asbestos Content Pink Drywall with Brown Paper ND

Off-White Joint Compound ND Cream Tape ND

Off-White Texture with Paint ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Location: SVC-B-102-CDW03-01, Composite Drywall / Joint Compound Lab ID-Version‡: 8463412-1

Sample Layers Asbestos Content Pink Drywall with Brown Paper ND

Off-White Joint Compound ND Cream Tape ND

Off-White Texture with Paint ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Location: SVC-B-106-CDW03-02, Composite Drywall / Joint Compound Lab ID-Version‡: 8463413-1

Sample Layers Asbestos Content Pink Drywall with Brown Paper ND

Off-White Joint Compound ND Cream Tape ND

Off-White Texture with Paint ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

EMLab ID: 1808578, Page 4 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: SVC-A-113-CDW04-01, Composite Drywall / Joint Compound Lab ID-Version‡: 8463414-1

Sample Layers Asbestos Content Pink Drywall with Brown Paper ND

Off-White Joint Compound 2% Chrysotile Cream Tape ND

Off-White Compound with Paint < 1% Chrysotile White Texture with Paint ND

Composite Asbestos Fibrous Content: < 1% Asbestos Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.

EMLab ID: 1808578, Page 5 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: SVC-A-114-CDW04-02, Composite Drywall / Joint Compound Lab ID-Version‡: 8463415-1

Sample Layers Asbestos Content Pink Drywall with Brown Paper ND

Off-White Joint Compound 2% Chrysotile Cream Tape ND

Off-White Compound with Paint 2% Chrysotile White Texture with Paint ND

Composite Asbestos Fibrous Content: < 1% Asbestos Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.

Location: SVC-C-AT-DS01-01, Duct Sealant Lab ID-Version‡: 8463416-1

Sample Layers Asbestos Content Semi-Transparent Sealant ND

Sample Composite Homogeneity: Good

Location: SVC-A-101-FM01-01, Flooring Mastic Lab ID-Version‡: 8463417-1

Sample Layers Asbestos Content Yellow Mastic ND

Gray Leveling Compound ND Sample Composite Homogeneity: Moderate

Location: SVC-B-102-FM02-01, Flooring Mastic Lab ID-Version‡: 8463418-1

Sample Layers Asbestos Content Yellow Mastic ND

Composite Non-Asbestos Content: 5% Synthetic Fibers Sample Composite Homogeneity: Good

EMLab ID: 1808578, Page 6 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: SVC-A-109-FTC01-01, Floor Tile and Mastic Lab ID-Version‡: 8463419-1

Sample Layers Asbestos Content Gray Floor Tile 3% Chrysotile Black Mastic 3% Chrysotile

Sample Composite Homogeneity: Moderate

Location: SVC-A-122-FTC01-02, Floor Tile and Mastic Lab ID-Version‡: 8463420-1

Sample Layers Asbestos Content Gray Floor Tile 3% Chrysotile

Black/Yellow Mastic 7% Chrysotile Sample Composite Homogeneity: Moderate

Location: SVC-B-106-FTC02-01, Floor Tile and Mastic Lab ID-Version‡: 8463421-1

Sample Layers Asbestos Content Red Floor Tile ND

Black/Yellow Mastic ND Sample Composite Homogeneity: Moderate

Location: SVC-A-112-IB01-01, Insulation Board with Sealant Lab ID-Version‡: 8463422-1

Sample Layers Asbestos Content Yellow Insulation with Coating ND

Composite Non-Asbestos Content: 80% Glass Fibers 10% Cellulose

Sample Composite Homogeneity: Moderate

EMLab ID: 1808578, Page 7 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: SVC-A-112-IB01-02, Insulation Board with Sealant Lab ID-Version‡: 8463423-1

Sample Layers Asbestos Content Yellow Insulation with Coating ND

Composite Non-Asbestos Content: 60% Glass Fibers 25% Cellulose

Sample Composite Homogeneity: Moderate

Location: SVC-B-103-LIP01-01, Lay-In Ceiling Panel Lab ID-Version‡: 8463424-1

Sample Layers Asbestos Content Gray Ceiling Tile with Foil ND

Composite Non-Asbestos Content: 60% Glass Fibers 5% Cellulose

Sample Composite Homogeneity: Good

Location: SVC-C-AT-RM01-01, Asphaltic Roofing Material Lab ID-Version‡: 8463425-1

Sample Layers Asbestos Content Brown Fiberboard ND

Black Roofing Shingle with Tan Pebbles ND Composite Non-Asbestos Content: 50% Cellulose Sample Composite Homogeneity: Poor

Location: SVC-A-113-TS01-01, Texture Wall Surfacing Lab ID-Version‡: 8463426-1

Sample Layers Asbestos Content White Texture with Paint ND

Sample Composite Homogeneity: Good

EMLab ID: 1808578, Page 8 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: SVC-A-113-TS01-02, Texture Wall Surfacing Lab ID-Version‡: 8463427-1

Sample Layers Asbestos Content White Texture with Paint ND

Sample Composite Homogeneity: Good

Location: SVC-A-113-TS01-03, Texture Wall Surfacing Lab ID-Version‡: 8463428-1

Sample Layers Asbestos Content Off-White Compound with Paint 2% Chrysotile

White Texture with Paint ND Sample Composite Homogeneity: Moderate

Location: SVC-A-113-TS02-01, Texture Wall Surfacing Lab ID-Version‡: 8463429-1

Sample Layers Asbestos Content Off-White Compound with Paint < 1% Chrysotile

White Texture with Paint ND Sample Composite Homogeneity: Moderate

Location: SVC-A-113-TS02-02, Texture Wall Surfacing Lab ID-Version‡: 8463430-1

Sample Layers Asbestos Content White Texture with Paint ND

Sample Composite Homogeneity: Good

EMLab ID: 1808578, Page 9 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Landmark Environmental, Inc.

C/O: Brandy Howard, CIH Re: 17075.001.001; Moraine Park Discovery Ctr.

RMNP

Date of Sampling: 09-27-2017 Date of Receipt: 10-06-2017 Date of Report: 10-09-2017

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: SVC-A-113-TS02-03, Texture Wall Surfacing Lab ID-Version‡: 8463431-1

Sample Layers Asbestos Content White Texture with Paint ND

Sample Composite Homogeneity: Good

Location: SVC-A-110-UC01-01, Undercoating on Sink Pan Lab ID-Version‡: 8463432-1

Sample Layers Asbestos Content Gray Sink Undercoating ND

Sample Composite Homogeneity: Good

EMLab ID: 1808578, Page 10 of 10EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

Fog Rain Snow Wind Clear www.EMLabPK.com

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X

X

X

SVC-C-AT-RM01-01 Asphaltic Roofing Material B ND N/A N/A

SVC-B-103-LIP01-01 Lay-in Ceiling Panel B ND N/A N/A

SVC-A-112-IB01-02 Insulation Board with Sealant B ND N/A N/A

SVC-A-112-IB01-01 Insulation Board with Sealant B ND N/A N/A

SVC-B-106-FTC02-01 Floor Tile and Mastic B ND N/A N/A

SVC-A-122-FTC01-02 Floor Tile and Mastic B ND N/A N/A

SVC-A-109-FTC01-01 Floor Tile and Mastic B ND N/A N/A

SVC-B-102-FM02-01 Flooring Mastic B ND N/A N/A

SVC-A-101-FM01-01 Flooring Mastic B ND N/A N/A

SVC-C-AT-DS01-01 Duct Sealant B ND N/A N/A

N/A N/A

SVC-A-114-CDW04-02 Composite Drywall / Joint Compound B ND N/A N/A

B ND N/A N/A

SVC-B-106-CDW03-02 Composite Drywall / Joint Compound B ND N/A N/A

N/A N/A

SVC-C-B1-CDW02-02 Composite Drywall / Joint Compound B ND N/A N/A

N/A N/A

SVC-A-122-CDW01-02 Composite Drywall / Joint Compound B ND N/A N/A

Textured Wall Surfacing

Undercoating on Sink Pan

Baseboard Adhesive

Textured Wall Surfacing

Textured Wall Surfacing

Textured Wall Surfacing

Textured Wall Surfacing

Textured Wall Surfacing

Composite Drywall / Joint Compound

Composite Drywall / Joint Compound

Composite Drywall / Joint Compound

Composite Drywall / Joint Compound

SVC-A-113-TS02-03

SVC-A-110-UC01-01

SVC-C-M3-BBA01-01

SVC-A-113-TS01-01

SVC-A-113-TS01-02

SVC-A-114-TS01-03

SVC-A-114-TS02-01

SVC-A-114-TS02-02

SVC-A-109-CDW01-01

SVC-C-M3-CDW02-01

SVC-B-102-CDW03-01

SVC-A-113-CDW04-01

By submitting this Chain of Custody, you agree to be bound by the terms and conditions set forth at www.emlabpk.com/terms.html Copyright © 2002-2009 EMLab P&K

Company: Landmark Environmental

Contact: Brandy Howard

Phone/Email:720-878-6475

7881 Shaffer PKWY, Littleton, CO 80127 Special Instructions:Email results to bhoward@landmarkenviro.com

BC - BioCassette™ ST - Spore Trap: Zefon, Allergenco, Burkard…

T - Tape D - Dust

A1S - Andersen SW - Swa SO - Soil

NP - Non-Potable Water O - Other:

SAS - Surface Air Sam P - Potable Water B - Bulk

CP - Contact Plate

N/A N/A

SAMPLE TYPE CODES RELINQUISHED BY DATE & TIME

B ND

N/A

N/A N/A

N/A N/A

N/A

N/A N/AB ND

B ND

B ND

B ND

B ND

N/A N/AB ND

B ND

B ND

B ND

B

N/A N/A

ND

N/A N/A

N/A N/AB

N/A N/A

N/A N/A

N/A N/A

ND

B ND

B ND

B ND

-M e d ia

S u rf a ce F u n g i (

G e n u s

ID

A sp sp p.

PROJECT INFORMATION

Sample

Type

(Below

TAT

(Abov e)

Total

Volume/Area

(as Sample ID Description

PO Number: WH - Weekend/Holiday

CONTACT INFORMATION

Project Desc.:Moraine Park Discovery Ctr. RMNP

P

C R p le a se s p e ci fy t e st

G ra m

S ta in a n d

C o u n ts

C u ltu ra b le

A ir a n d S u rf a ce

B a ct e ri a

Le gi on el la c ul tu re

T o ta l C o lif o rm E

.c ol i (P re se nc e/

A bs en ce

M e m b ra n e F ilt ra tio n

P le a se s p e ci fy o rg a n is m e d ia

S u rf a ce F u n g i (

G e n u s

ID

A sp sp p.

None

Marlton, NJ: 3000 Lincoln Drive East,Suite A Marlton, NJ 08053 (866) 871-1984 Phoenix, AZ: 1501 West Knudsen Drive, Phoenix, AZ 85027 * (800) 651-4802 S. San Francisco, CA: 6000 Shorline Ct. Ste 203, S. San Francisco, CA 94080 * (866) 888-6653

TURN AROUND TIME CODES - (TAT)

Project ID:17075.001.001 STD - Standard (DEFAULT) Rushes received after 2pm or on weekends, will be considered received the next business day.

Please alert us in advance of weekend analysis needs.

ND - Next Business Day Project Zip Code:

Sampling9-27-2017/ 0930 Date & Time: SD - Same Business Day Rush

Q u a n tiT ra y

S e w a g e S cr e n e d ia

S u rf a ce F u n g i (

G e n u s

ID

A sp sp p.

CHAIN OF CUSTODY WEATHER

Light Non-Culturable

L E

V E

L

NOTES

(Time of day, Temp, RH, etc.)

Culturable

REQUESTED SERVICES ( Boxes)

Other Requests

Moderate Spore Trap

Tape Swab Bulk

BioCassette ™, Andersen, SAS, Swab, Water, Bulk, Dust, Soil, Heavy

S p o re T ra p

A n a ly si s

O th e r p a rt ic le s

RECEIVED BY DATE & TIME

A sb e st o s A n a ly si s

P C

M A ir bo rn e

F ib er C ou nt

N

IO

S

H

A sb e st o s A n a ly si s

P L

M

E P

A m e th o d

/R

-9

-1

M

P N

B a ct e ri a

P le a se s p e ci fy o rg a n is

C ltu ra b le A ir F u n g i (

G e n u s

ID

A sp sp p.

F n g i -

S p o re

T ra p A n a ly si s

D ir e ct M ic ro sc o p ic

E xa m

Q u a lit a tiv

Q a n tit a tiv e S p o re C o u n t

D ir e ct

E xa

Doc. # 200176 Rev: 24 Revised: 6/29/09 Page 1 of 1, QAD

Attachment B

LEAD CONTAINING PAINT SAMPLE INFORMATION & ANALYTICAL RESULTS

Landmark Environmental, Inc. Lead Paint Inspection Form 7881 Shaffer Parkway Littleton, Colorado 80127 720-283-8975 Fax: 720-283-8666

Client: Anderson Hallas Architects

NPS Contract

Project: 17075.001.001

Kawuneeche Visitor Center

Date: 10/4/17

Inspector: Tristan Fitzpatrick

Sample # Location Component Substrate Color Condition Result

RES 391516

SVC-A-117-LBP01

South wall at west of door, 4’ up. Main

Building, ~1963 Construction Era Wall Drywall White Good BRL

SVC-B-102-LIP02

North wall at 103 door, 1’ up. Visitors Center

Addition, ~1989 Construction Era Wall Wood Army Green Good BRL

SVC-B-105-LIP03

South wall at east of entry door. Visitors

Center Addition, ~1989 Construction Era Wall Drywall White Good BRL

SVC-B-105-LIP04

Half wall in room, on trim board. Visitors

Center Addition, ~1989 Construction Era Trim Wood Brown Good BRL

SVC-B-EXT-LBP05

At south-west corner, exterior of room 103.

Visitors Center Addition, ~1989 Construction

Era Exterior Wall Wood

Dark

Green/Brown Good BRL

SVC-B- EXT-LBP06

At south-west corner, exterior of room 103.

Visitors Center Addition, ~1989 Construction

Era Exterior Trim Wood

Light

Green/Grey Good BRL

SVC-A-EXT-LBP07

At south-east corner, exterior of room 121.

Main Building, ~1963 Construction Era Exterior Wall Wood

Dark

Green/Brown Good 0.070 %

SVC-A-EXT-LBP08

At south-east corner, exterior of room 121.

Main Building, ~1963 Construction Era Exterior Trim Wood

Light

Green/Grey Good 0.076 %

SVC-C-EXT-LBP09

At south west corner, exterior of room B1.

Detached Bathroom / Comfort Building, ~1963 Construction Era Exterior Wall Wood

Dark

Green/Brown Good 0.069 %

SVC-C-EXT-LBP10

At south west corner, exterior of room B1.

Detached Bathroom / Comfort Building, ~1963 Construction Era Exterior Trim Wood

Light

Green/Grey Good 0.083 %

BRL – Below Reporting Limit at the laboratory

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2016

T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 391516-1 Project # / PO #: 17075.001.001 Project Description:

RES 391516-1

Sincerely, Jeanne Spencer

President

October 9, 2017

Dear Customer, Reservoirs has analyzed the following sample(s) using Atomic Absorption Spectroscopy (AAS) / Atomic Emission

Spectroscopy - Mass Spectrometry (ICP-MS) per your request. Reported sample results were not blank corrected. The analysis has been completed in general accordance with the appropriate methodology as stated in the analysis table.

Results have been sent to your office.

property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those authorized by the client. The results described in this report only apply to the samples analyzed. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you should have any questions about this report, please feel free to call me at 303-964-1986.

Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and

Environmental matrices by the American Industrial Hygiene Association, Lab ID 101533 - Accreditation Certificate #480.

The laboratory is currently proficient in both IHPAT & ELPAT programs respectively.

is the job number assigned to this study. This report is considered highly confidential and the sole

Kawuneeche Visitors Center

Littleton CO 80217

7881 Shaffer Parkway

Tristan Fitzpatrick

Landmark Environmental, Inc.

P: 303-964-1986

F: 303-477-4275

5801 Logan Street, Suite 100 Denver, CO 80216

1-866-RESI-ENV

www.reilab.com

Effective January 1, 2016

T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

RES Job Number:

Client:

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Analysis Type:

Turnaround:

Date Samples Analyzed:

Client Lab Reporting LEAD

ID Number ID Number Limit CONCENTRATION

SVC-A-117-LBP01 EM 1967186 0.0092 BRL

SVC-B-102-LBP02 EM 1967187 0.0082 BRL

SVC-B-105-LBP03 EM 1967188 0.0055 BRL

SVC-B-105-LBP04 EM 1967189 0.020 BRL

SVC-B-EXT-LBP05 EM 1967190 0.0059 BRL

SVC-B-EXT-LBP06 EM 1967191 0.0030 BRL

SVC-A-EXT-LBP07 EM 1967192 0.0034 0.070

SVC-A-EXT-LBP08 EM 1967193 0.0048 0.076

SVC-C-EXT-LBP09 EM 1967194 0.0054 0.069

SVC-C-EXT-LBP10 EM 1967195 0.0074 0.083

Analyst / Data QA:________________________

24 Hour

RESERVOIRS ENVIRONMENTAL, INC.

5801 Logan St., Suite 100

Denver CO 80216

TABLE ANALYSIS: LEAD IN PAINT

RES 391516-1

October 9, 2017

* Unless otherwise noted all quality control samples performed within specifications established by the laboratory.

Landmark Environmental, Inc.

17075.001.001 Kawuneeche Visitors Center October 6, 2017

USEPA SW846 3050B / AA (7420)

BRL = Below Reporting Limit

P: 303-964-1986

F: 303-477-4275

5801 Logan Street, Suite 100 Denver, CO 80216

Effective January 1, 2016

T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 391517-1 Project # / PO #: 17075.001.001 Project Description:

RES 391517-1

Sincerely, Jeanne Spencer

President

October 9, 2017

Dear Customer, Reservoirs has analyzed the following sample(s) using Atomic Absorption Spectroscopy (AAS) / Atomic Emission

Spectroscopy - Mass Spectrometry (ICP-MS) per your request. Reported sample results were not blank corrected. The analysis has been completed in general accordance with the appropriate methodology as stated in the analysis table.

Results have been sent to your office.

property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those authorized by the client. The results described in this report only apply to the samples analyzed. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you should have any questions about this report, please feel free to call me at 303-964-1986.

Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and

Environmental matrices by the American Industrial Hygiene Association, Lab ID 101533 - Accreditation Certificate #480.

The laboratory is currently proficient in both IHPAT & ELPAT programs respectively.

is the job number assigned to this study. This report is considered highly confidential and the sole

Kawuneeche Visitors Center

Littleton CO 80217

7881 Shaffer Parkway

Brandy

Landmark Environmental, Inc.

P: 303-964-1986

F: 303-477-4275

5801 Logan Street, Suite 100 Denver, CO 80216

Effective January 1, 2016

T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

RES Job Number:

Client:

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Analysis Type:

Turnaround:

Date Samples Analyzed:

Client Lab Reporting LEAD

ID Number ID Number Limit CONCENTRATION (mg/kg) (mg/kg)

SVC-EX-SOIL EM 1967185 13.4 13.4

Analyst / Data QA:________________________

24 Hour

RESERVOIRS ENVIRONMENTAL, INC.

5801 Logan St., Suite 100

Denver CO 80216

TABLE ANALYSIS: LEAD IN SOIL

RES 391517-1

October 9, 2017

* Unless otherwise noted all quality control samples performed within specifications established by the laboratory.

Landmark Environmental, Inc.

17075.001.001 Kawuneeche Visitors Center October 6, 2017

USEPA SW846 3050B / AA (7420)

BRL = Below Reporting Limit

P: 303-964-1986

F: 303-477-4275

5801 Logan Street, Suite 100 Denver, CO 80216

Attachment C

PHOTOGRAPHS

LANDMARK

Project No.

17075.001.001

Description BBA01 Photo 1

Site Name Kawuneeche Visitors Center Photo Date

10/06/2017

17075.001.001

Description CDW01 Photo 2

Site Name Kawuneeche Visitors Center

17075.001.001

Description CDW02 Photo 3

Site Name Kawuneeche Visitors Center

17075.001.001

Description CDW03 Photo 4

Site Name Kawuneeche Visitors Center

17075.001.001

Description CDW04 Photo 5

Site Name Kawuneeche Visitors Center

17075.001.001

Description DS01 Photo 6

Site Name Kawuneeche Visitors Center

17075.001.001

Description FM01 Photo 7

Site Name Kawuneeche Visitors Center

17075.001.001

Description FM02 Photo 8

Site Name Kawuneeche Visitors Center

17075.001.001

Description FTC01 Photo 9

Site Name Kawuneeche Visitors Center

17075.001.001

Description FTC02 Photo 10

Site Name Kawuneeche Visitors Center

17075.001.001

Description IB01 Photo 11

Site Name Kawuneeche Visitors Center

17075.001.001

Description LIP01 Photo 12

Site Name Kawuneeche Visitors Center

17075.001.001

Description RM01 Photo 13

Site Name Kawuneeche Visitors Center

17075.001.001

Description TS01 Photo 14

Site Name Kawuneeche Visitors Center

17075.001.001

Description TS02 Photo 15

Site Name Kawuneeche Visitors Center

17075.001.001

Description UC01 Photo 16

Site Name Kawuneeche Visitors Center

National Park Service | Harpers Ferry Center

Exhibit Planning, Design, and Fabrication Specifications ATTACHMENT 1 - IDIQ Exhibit Planning & Design Contract

April 2020

Contents

1. Definitions 3

2. Project Management 12

3. Exhibit Planning, Design, and Fabrication Process 15

4. Travel, Meetings, and Presentations 32

5. Submittals and Reviews 37

6. Accessibility 39

7. Exhibit Evaluation 42

8. Production Cost Estimates 45

9. Exhibit Visualization 50

10. Resource Packages 52

11. Content Management 54

12. Text 60

13. Exhibit Drawings 65

14. Materials, Colors, and Finishes 72

15. Two-Dimensional Exhibit Graphics 76

16. Content Specialties 99

17. Use Rights and Licenses 111

18. Object Preservation and Protection 113

19. Electronic Programs 122

20. Electronic Equipment 127

21. Tactile Exhibit Elements and Mechanical Interactives 139

22. Design Guidelines for Exhibit Structures 144

23. Exhibit Lighting 146

24. Mock-Ups and Prototypes 150

25. Planning & Design Support During Fabrication 152

26. Maps 155

27. Quality Standards and Safety for Fabrication 160

28. Shop Inspections and Installation 166

29. Operational Training and References 173

30. Closeout 181

31. Audio Description 186

1. Definitions

ABAAS: Architectural Barriers Act Accessibility Standards are the accessibility standards which per-tain to the Federal sector. The ABA, or Architectural Barriers Act of 1968, requires access to facilities designed, built, altered, or leased with federal funds. (See also “Accessible,” “ADA,” and “Rehabilita-tion Act.”)

Accessible: In context with the requirements of this contract, accessible is defined as in compliance with accessibility standards as specified in the Programmatic Accessibility Guidelines for National Park Service Interpretive Media. Federal laws, including the Architectural Barriers Act Accessibility Standards (ABAAS) and Sections 504 and 508 of the Rehabilitation Act, shall be followed. Universal Design and its seven principles shall be applied as a part of the NPS definition and requirements.

Accessioned Objects (AO): Objects accessioned into the park collection, or objects on loan from other institutions. These items require the highest level of preservation and security criteria. Historic objects also include original period items acquired as part of the exhibit project to enhance interpre-tation. Park staff determines whether to accession these objects on a case by case basis.

ADA: Americans with Disabilities Act of 1990. This law prohibits discrimination against individuals on the basis of disability. It applies to state and local governments, and public accommodations oper-ated by the private sector. While there are exceptions, it does not generally apply to media and exhibi-tions that are federally funded and installed in federal facilities. Therefore, the term “ADA” or “ADA compliant” should not be used when referring to accessibility compliance in Federal Government owned and operated facilities. (See also “ABAAS” and “Rehabilitation Act.”)

Artifacts: See “Accessioned Objects.”

As-Built AV Drawings: Final design and detail drawings updated by the contractor to reflect all changes that occur during installation and provide a record of the “as-built” condition of the AV, or Electronic Equipment, systems. Drawings include all equipment, cables, connectors, connections points, and devices.

As-Built Exhibit Plan: The fabrication contractor updates exhibition content data (e.g., text, con-tent schedules, technical data, etc.) to reflect all changes that occur during fabrication and installation, and provides a record of the “as-built” condition of the exhibits, which may vary from the final design documents prepared by the exhibit planning & design contractor.

As-Built Exhibit Drawings: Final design and detail drawings updated by the fabrication contrac-tor to reflect all changes that occur during fabrication and installation and provide a record of the “as-built” condition of the exhibits, which may vary from the final design documents prepared by the exhibit planning & design contractor.

As-Built Lighting Plan: A final plan drawing for the installed exhibit lighting system showing fix-ture placement, focusing information, and itemized lists detailing fixture, accessory, and lamp data.

Assistive Listening Systems: Assistive listening is used by persons with mild to profound hearing loss who may or may not use a hearing aid. These systems are a suite of equipment used to deliver sound directly from its source to the person receiving it. The receiving person can also amplify the sound based on their needs. The amplified sound is transmitted via radio frequency or infrared to a receiver connected to the person’s headset, ear buds, or an induction loop that transmits the sound to the person’s hearing aid.

Audience-Centered Experience (ACE): Audience Centered Experiences are the practice of elicit-ing participation and contribution from an audience and community.

Audience-centered interpretation can infuse any and all park experiences by providing opportunities for audience members to contribute to the meaning-making process, engage with each other, and

April, 2020

Definitions | 3

National Park Service | Standard Exhibit Planning, Design, and Fabrication Specifications

4 | Definitions explore the current social context of national park resources.

AV Program Concept Treatment: A narrative overview of the proposed production’s creative approach and storyline prepared during the exhibit planning and design process. AV Concept Treat-ments typically include a description of the actors and/or participants, their roles and general dia-logue or narration, and a general description of the scenes, locations, graphics, artwork, and anima-tion to be used in the production with sufficient detail to provide a sense of the proposed production;

the basis of the production plan and script.

Audio Description (AD): Through words, AD describes visual content essential for understanding the content of a program. Audio description is used for a variety of media, including video, digital interactive programs and exhibits. People who are blind or have low vision are the primary audience, but audio description can also be used by people who have print disabilities or auditory learning styles. AD is typically scripted and recorded by a professional. In some cases, AD text may be read by a screen reader and synthesized voice. Specific delivery systems and techniques vary based on the media and venue. AD is also referred to as video description, verbal description, descriptive video and descriptive audio.

AV Program Production Plan: A document which presents the major categories of work to be performed in the planning, production, and post-production phases of the program. The Production Plan shall describe all of the elements required to produce the program as outlined in the Treatment and/or Scope of Work, including, but not limited to: production personnel (including the use and identification of sub-contractors, consultants, and other salaried employees of the firm), equipment, post-production facilities, travel, transportation, and a cost estimate of all materials expenses such as capture and storage media, and archival images. Within the Production Plan, the contractor shall con-firm that they understand the “Rights in Data—Special Works” requirements of the contract, includ-ing rights for music, stock footage, and other elements.

AV Program Production Treatment: A narrative description of the proposed production ele-ments to include an estimated percentage of the program that will be comprised of original, archival, or stock materials (including footage, photographs, or audio); reenactments; interviews; animation;

graphics; and illustrations; and the proposed source(s) for such materials. It shall also include a description of the narration, sound effects, and musical score, to include whether the score shall be comprised of original or stock music. The AV Production Treatment provides the basis of the AV Pro-duction Plan and script.

Audiovisual (AV) program: One type of Electronic Program (EP). AV programs include linear programs with fixed running times. Through the use and/or integration of numerous elements such as sound effects, music, voice-overs, interviews, moving and historic images, AV programs can be innate-ly dynamic. They are especially effective in eliciting emotional responses, telling stories, and conveying concepts where motion and/or sound are important or particularly effective. Throughout these spec-ifications “AV” is also used an as umbrella term to refer collectively to Audiovisual Programs, Digital Interactive Programs, and Electromechanical Programs.

Bubble Diagrams: Diagrams that use labeled shapes (bubbles) identifying exhibit themes and con-cepts to show how they relate to each other and/or to their location on the exhibit floor plan.

Captions: Captions are designed for persons who are deaf or have hearing loss. The terms “cap-tions” and “Subtitles for the Deaf and Hard of Hearing” (SDH) are used interchangeably in these specifications. They display spoken dialogue and non-speech information as printed words on tele-vision screens, computer monitors, projection screens, caption boards and other visual displays.

Non-speech information is audible information essential to understanding the content. Examples of non-speech information include speaker identification, sound effects, music, manner of speaking (whispering, word emphasis, emotion, etc.) and audience reactions (laughing, booing, etc.) Captions may hold secondary benefits for people who are learning a foreign language, learning how to read, Definitions | 5 watching a program in a noisy area, or understand best by processing visual information. While used as a catch-all term, different types of “captions” have their own unique technical production, pro-gramming, coding, playback, and/or decoding processes. Captions are either closed or open:

Closed Captions (CC): Closed captions do not appear on screen unless the viewer has selected them to appear. They require decoding technology. Closed captions are generally produced for online videos and DVD/BluRay discs. Closed captions shall not be used for audiovisual programs shown in NPS venues.

Open Captions (OC): Open captions are displayed on the screen at all times automatically as part of the video. There is no option to turn the captions on or off. They are “burned” into the picture. All audiovisual programs shown within NPS venues must display captions on-screen at all times. For NPS productions requiring open captions, contractors shall use a pro-duction process which allows control of font selection, size, color, edging, and other design parameters.

Charette: A meeting to brainstorm and fully explore all possible design directions for presentation and communication of content in the exhibition. Differs from the Exhibit Planning Workshop in that it is more focused on design solutions.

Class A Production Cost Estimate: Detailed cost estimate which includes an itemized break-down, at a minimum, of labor hours and rates, material costs, shipping, and travel, based on specifica-tions for all exhibit elements found in the Production Documents.

Class B Production Cost Estimate: An intermediate level cost estimate based on allocating an overall cost for each exhibit Scene or Content Group in the exhibition plan, and including allowances for all high-cost exhibit elements currently identified, contingency, shipping, and installation. Class B Production Cost Allowances/Estimates are used during the Schematic and Design Development phases of work, and become increasingly detailed as the design progresses.

Class C Production Cost Estimate: An initial cost estimate based on the cost of the exhibition per square foot. Class C estimates are used during the Pre-Design phase of work.

Closed Captions: See “Captions”

Comprehensive Exhibit Plan: A report from a Content Management Database that includes a comprehensive list of all exhibit elements, including AOs, CAs, CEs, EEs, EPs, GLs, IMs, and LAs.

Content Development: See Exhibit Planning.

Content Group: A discrete thematic story or information set within an exhibition that, together with adjacent related Content Groups, is part of a larger Scene. A Content Group tells one aspect of the larger story or information presented in the overall Scene.

Content Management: A system to organize and track all media elements to be featured in the exhibition, organized by unique exhibit element number.

Content Management Numbering System: A system that identifies each exhibit element with a unique number (the Element Identification Number) made up of three parts, separated by hyphens, as follows: Element Type - Scene - Content Group Number - Item Number. For example, IM-02-04-

Content Specialties: Any exhibit element that requires detailed subject matter, creative, technical, and/or artistic input to inform and direct its production by a creative or technical specialist. These elements include, but are not limited to, original artwork, sculptures, models, reproductions, objects, dioramas, life-sized figures, and electronic programs.

Content Specialties Reference Package: A document consisting of written descriptions and graphic depictions that together provide the background information and design intent needed for

6 | Definitions an artist, craftsman, or technical specialist to produce a custom element. Prepared during the Design Development and Production Design phases of exhibit planning and design.

Contracting Officer’s Representative (COR): For Federal Government contracts, an authorized representative of the Contracting Officer responsible for monitoring the quality and performance of work performed under individual contracts.

Custom Element (CE): General category for three-dimensional content in an exhibition that is not otherwise categorized. Custom Elements may be commercially available items, but more often are specifically created for the exhibition, requiring creative design, and/or artistic development and execution. Examples include sculptures, architectural models, natural history models, reproduction historic objects, dioramas, manipulatives, electrical and mechanical interactive devices, mannequins, and topographic maps. Custom Elements are tracked in the Content Management Numbering Sys-tem, and are inventoried in FMSS where they are designated as “Custom Three-Dimensional Exhibit Elements.”

Custom Three-Dimensional Exhibit Element: Term used for FMSS inventory. See Custom Element.

Design Alternatives: Distinct approaches to the exhibit content, its organization and presentation in the given exhibition space. Multiple Design Alternatives (usually three) are developed in the Sche-matic Design 1 phase of work as part of the process used to arrive at a Preferred Design Alternative.

Design Development: The phase of the exhibit development process in which all major content and design details of the project are completed. Technical details required for Production are not included in this phase of work.

Digital Interactive program: One type of Electronic Program (EP), which is often non-linear.

These programs encourage users to become engaged through interaction, exploration, and learning at their own pace and may include multiple layers of information.

Electromechanical program: One type of Electronic Program (EP). Electromechanical programs include but are not limited to electronic programming such as LED lights within a map, diorama, or other exhibit element; lighting programmed to be synchronous or otherwise function in concert with exhibits or exhibit elements; and motion sensors programmed to trigger lighting, audiovisual, digital interactive, or mechanical exhibit elements.

Electronic Equipment (EE): All electronic and ancillary equipment required to present or support the presentation of Electronic Programs, Assistive Listening, and Audio Description, in an exhibition, including any programmed lighting and electromechanical devices.

This is the start of the file's text. The full file is on GovTribe.