B02_Attatchment_2_26_0330_-_ROMO_KVC_326235_Final_CD_Drawing_Set_Part1.pdf
PDF 26 MB Posted
- Solicitation number
- 140P2026R0057
About this file
This is a Final Construction Documents drawing set for the Kawuneeche Visitor Center rehabilitation project at Rocky Mountain National Park in Grand Lake, Colorado. The project involves comprehensive rehabilitation of the historic 1968-1969 Mission 66 architecture facility, which consists of three connected nodes: an administrative wing, visitor center with exhibits and auditorium, and comfort station. The work includes accessibility upgrades, new interior finishes, doors and windows, paint and stain refinishing, signage, and upgrades to electrical, plumbing, mechanical, and technology systems, along with installation of a new fire suppression system throughout the building.
The construction documents classify the project as an IEBC Alteration Level 3 with IBC Type VB construction serving mixed occupancies (A-3 Assembly and B Business). The building footprint totals approximately 9,876 square feet across three buildings connected by interior and exterior covered walkways. The project reduces the maximum building height from approximately 19 feet 1 inch to 15 feet 8 inches. Work includes demolition of existing conditions, grading and site improvements involving approximately 49,000 square feet of earthwork with 200 cubic yards of cut and 520 cubic yards of fill, installation of hardscape materials including concrete sidewalks, asphalt parking, and utility infrastructure (water, fire service, storm and sanitary sewer systems). The design integrates Secretary of the Interior Standards for Historic Properties, preserving character-defining features including vertical steel and wood columns, native stone elements, glass curtain walls, wood and stone finishes, and Mission 66 era site furnishings while meeting 2024 International Building Code, 2024 International Energy Conservation Code, and Architectural Barriers Act Accessibility Standards requirements. The drawing set comprises 177 sheets organized into General, Civil, Architectural, Structural, Mechanical, Plumbing, Electrical, Technology, Fire Protection, and Fire Alarm disciplines.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TO
LYONS
AND
BOULDER
TO
LYONS AND
BOULDER
COUNTY
GRAND
COUNTY
BOULDER
GRANBY
TO
GRANBY
LAKE
LAKE
MOUNTAIN
SHADOW
FOREST
LAKE
GRAND
DIVIDE
CONTINENTAL
NATIONAL
ARAPAHO
COUNTY
LARIMER
C O U N
TY
G R A N D
C O U N
TY
LA
R
IM
E R
CONTINENTAL
DIVIDE
LONGS
PEAK
BOULDER
COUNTY
LARIMER
COUNTY
FOREST
GULCH
DEVILS
NATIONAL
ROOSEVELT
PARK
ESTES
ROAD
LOVELAND
TO
COLORADO
WYOMING
SPRINGS
STEAMBOAT
LEADVILLE
28524
VAIL
SPRINGS
IDAHO
GREELEY
GRANBY
LYONS
PARK
ESTES
LONGMONT
LOVELAND
COLLINS
FORT
COLORADO
WYOMING
PARK
NATIONAL
MOUNTAIN
ROCKY
SPRINGS
COLORADO
DENVER
BOULDER
CHEYENNE
PROJECT LOCATION
KAWUNEECHE VISITOR CENTER INTERIOR, 1969 (SOURCE: NPS)
KAWUNEECHE VISITOR CENTER EXTERIOR FROM SOUTH, 1969 (SOURCE: NPS)
KAWUNEECHE VISITOR CENTER EXTERIOR FROM NORTHEAST, 1969 (SOURCE: NPS)
Kawuneeche Visitor Center, 2024 (Source: AH)KAWUNEECHE VISITOR CENTER LOBBY DOORS, 1969 (SOURCE: NPS)
KAWUNEECHE VISITOR CENTER CORRIDOR BETWEEN LOBBY AND ADMIN, 1969 (SOURCE: NPS)
KAWUNEECHE VISITOR CENTER EXTERIOR FROM EAST, 1969 (SOURCE: NPS)
KAWUNECHEE VISITOR CENTER
HARBISON MEADOWS AREA
TEMPORARY ADMIN FACILITIES
INTERMOUNTAIN
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
OF
SHEET
DEPARTMENT OF THE INTERIOR
UNITED STATES
STATEREGION COUNTY
LOCATION WITHIN PARK
NAME OF PARK
TITLE OF DRAWING DRAWING NO.
PMIS/PKG NO.
QUALITY DESIGN CERTIFICATION
Prepared in Accordance with design Development (Title I)
Drawing No.
Variance from Design Development (Title I) Approved by Superintendent on
Date
OR
Construction Drawing Not Preceded by Design Development (Title I)
OR
Project Manager Date
InitialDateREVISIONSheetMark
KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
FINAL CONSTRUCTION DOCS
COLORADO
ANDERSON HALLAS ARCHITECTS, PC
STRUCTURAL:
JVA, INC.
BOULDER, CO
80302
PRIME / CIVIL:
OTAK
REDMOND, WA
98052
MECHANICAL /
PUMBING:
360 ENGINEERING
GOLDEN, CO
80403
ELECTRICAL:
AE DESIGN
DENVER, CO
80202
ARCHITECT:
ANDERSON
HALLAS, PC
GOLDEN, CO
80401
- 140P2022D0020
PMIS
FIRE PROTECTION:
INTERFACE
ENGINEERING, INC
PORTLAND, OR
97204
INTERMOUNTAIN GRAND COLORADO1/2
0/2
6 1
0:1 8:5
8 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
REHABILITATE KAWUNEECHE VISITOR CENTER
1 177
326235
165639
326235
PERSPECTIVE VIEW (NEW)
NOTE: BUILDING SHOWN FOR VISUALIZATION PURPOSES ONLY. RE: ENCLOSED DRAWINGS FOR SCOPE OF WORK.
ROCKY MOUNTAIN NATIONAL PARK
REHABILITATE KAWUNEECHE VISITOR CENTER AND
IMPROVE ACCESSIBILITY FOR VISITOR ENJOYMENT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 8:5
9 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
G001
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 2 177
SHEET INDEX
SHEET #
SUB
SHEET SHEET NAME
GENERAL
1 G000 COVER SHEET
2 G001 SHEET INDEX
3 G002 GENERAL INFO & ABBREVIATIONS
4 G003 CODE ANALYSIS
5 G004 CODE & ACCESSIBILITY PLAN
6 G005 ENERGY CODE ANALYSIS & ASSEMBLIES
7 G501 ACCESSIBLE MOUNTING HEIGHTS
CIVIL
8 GC001 LEGENDS AND ABBREVIATIONS
9 G600 ACCESSIBILITY PLANS KEY MAP
10 G601 ACCESSIBILITY PLANS I
11 G602 ACCESSIBILITY PLANS II
12 G603 ACCESSIBILITY PLANS III
13 C000 EXISTING CONDITIONS KEY MAP
14 C001 EXISTING CONDITIONS PLAN I
15 C002 EXISTING CONDITIONS PLAN II
16 C003 STAGING PLAN
17 C004 LIMITS OF DISTURBANCE PLAN
18 C005 TEMPORARY FACILITIES PLAN
19 C006 TEMPORARY VISITOR CENTER PLAN
20 C100 TESC & DEMO KEY MAP
21 C101 TESC & DEMOLITION PLAN I
22 C102 TESC & DEMOLITION PLAN II
23 C200 SITE KEY MAP
24 C201 SITE PLAN I
25 C202 SITE PLAN II
26 C203 SITE PLAN ENLARGEMENT I
27 C204 SITE PLAN ENLARGEMENT II
28 C205 SITE PLAN ENLARGEMENT III
29 C206 SITE PLAN ENLARGEMENT IV
30 C207 SITE PLAN ENLARGEMENT V
31 C300 ALIGNMENT CONTROL PLAN
32 C301 VISITOR PARKING LOT PLAN AND PROFILE I
33 C302 VISITOR PARKING LOT PLAN AND PROFILE II
34 C303 GRADING PLANS ENLARGEMENT KEY PLAN
35 C304 GRADING PLANS AND LAYOUT ENLARGEMENT A
36 C305 GRADING PLANS AND LAYOUT ENLARGEMENT B
37 C306 GRADING PLANS AND LAYOUT ENLARGEMENT C
38 C307 GRADING PLANS AND LAYOUT ENLARGEMENT D
39 C308 GRADING PLANS AND LAYOUT ENLARGEMENT E
40 C309 GRADING PLANS AND LAYOUT ENLARGEMENT F
41 C310 LAYOUT POINTS AND TYPICAL SECTIONS
42 C400 SIGNING AND STRIPING PLAN I
43 C401 SIGNING AND STRIPING PLAN II
44 C500 UTILITY PLAN
45 C501 WATER PLAN & PROFILE I FDC LINE AND 2" SERVICE
46 C502 WATER PLAN & PROFILE II FIRE SERVICE LINES
47 C503 STORM PLAN & PROFILE
48 C504 STORM SEWER PLAN & PROFILE
49 C505 SEWER PLAN & PROFILE
50 C600 SITE DETAILS I
51 C601 SITE DETAILS II
52 C602 SITE DETAILS III
53 C603 SITE DETAILS IV
54 C604 SITE DETAILS V
55 C605 SITE DETAILS VI
56 C606 SITE DETAILS VII
SHEET #
SUB
SHEET SHEET NAME
ARCHITECTURAL
57 AD01 OVERALL DEMO FLOOR PLAN
58 AD02 ENLARGED DEMO PLAN - ADMIN
59 AD03 ENLARGED DEMO PLAN - AUDITORIUM & EXHIBIT
60 AD04 ENLARGED DEMO PLANS - COMFORT STATION
61 AD05 OVERALL DEMO REFLECTED CEILING PLAN
62 AD10 OVERALL DEMO ROOF PLAN
63 A101 OVERALL FLOOR PLAN
64 A102 ENLARGED PLAN - ADMIN
65 A103 ENLARGED PLAN - AUDITORIUM & EXHIBIT
66 A104 ENLARGED PLAN - COMFORT STATION
67 A105 OVERALL REFLECTED CEILING PLAN
68 A106 ENLARGED REFLECTED CEILING PLAN - EXHIBIT
69 A110 OVERALL ROOF PLAN
70 A201 EXTERIOR ELEVATIONS
71 A202 EXTERIOR ELEVATIONS
72 A301 BUILDING SECTIONS
73 A401 INTERIOR ELEVATIONS
74 A402 INTERIOR ELEVATIONS
75 A403 INTERIOR ELEVATIONS
76 A404 INTERIOR ELEVATIONS
77 A501 DOOR SCHEDULE
78 A502 DOOR DETAILS AND ENLARGED PLAN
79 A503 DOOR DETAILS
80 A510 WINDOW SCHEDULE
81 A511 WINDOW DETAILS
82 A520 FINISH PLAN & SCHEDULE
83 A601 EXTERIOR DETAILS
84 A602 EXTERIOR DETAILS
85 A603 EXTERIOR DETAILS - LPS DOWNLEADS
86 A610 INTERIOR DETAILS
STRUCTURAL
87 S000 STRUCTURAL GENERAL NOTES
88 S001 STRUCTURAL GENERAL NOTES
89 S002 STRUCTURAL ABBREVIATIONS & SYMBOLS
90 S101 FOUNDATION & FIRST FLOOR PLAN
91 S102 ROOF FRAMING PLAN
92 S601 COMFORT STATION SECTIONS
93 S602 ADMIN & VC SECTIONS
MECHANICAL
94 M000 MECHANICAL LEGENDS & NOTES
95 M101 OVERALL DEMO MECHANICAL FLOOR PLAN
96 M111 OVERALL MECHANICAL FLOOR PLAN
97 M112 OVERALL MECHANICAL ROOF PLAN
98 M300 MECHANICAL SECTIONS
99 M400 MECHANICAL DEMO ENLARGED PLANS
100 M401 MECHANICAL ENLARGED PLANS
101 M500 MECHANICAL DETAILS
102 M600 MECHANICAL SCHEDULES
103 M700 MECHANICAL CONTROLS SEQUENCES
104 M800 MECHANICAL CALCS AND COMCHECK
105 M801 MECHANICAL CALCS AND COMCHECK
PLUMBING
106 P000 PLUMBING LEGENDS AND NOTES
107 P101 OVERALL DEMO PLUMBING FLOOR PLAN
108 P111 OVERALL PLUMBING FLOOR PLAN - DOMESTIC & GAS
109 P121 OVERALL PLUMBING FLOOR PLAN - WASTE & VENT
110 P300 PLUMBING SECTIONS
111 P400 PLUMBING DEMO ENLARGED PLANS
112 P401 PLUMBING ENLARGED PLANS
113 P500 PLUMBING DETAILS
114 P600 PLUMBING SCHEDULES
115 P800 PLUMBING CALCS AND COMCHECK
116 P900 PLUMBING WASTE AND VENT ISOMETRICS
SHEET INDEX
SHEET #
SUB
SHEET SHEET NAME
ELECTRICAL
117 E000 ELECTRICAL COVER SHEET
118 E001 ELECTRICAL LEGENDS
119 E002 ELECTRICAL SITE PLAN
120 ED100 ELECTRICAL OVERALL DEMOLITION PLAN
121 ED101 ELEC ENLARGED DEMOLITION PLAN - ADMIN WING
122 ED102 ELEC ENLARGED DEMOLITION PLAN - AUDITORIUM/EXHIBIT PLAN
123 ED103 ELEC ENLARGED DEMOLITION PLAN - COMFORT STATION
124 E100 ELECTRICAL OVERALL POWER PLAN
125 E101 ELECTRICAL ENLARGED POWER PLAN - ADMIN WING
126 E102 ELECTRICAL ENLARGED POWER PLAN - AUDITORIUM/EXHIBIT
127 E103 ELEC ENLARGED POWER PLAN - COMFORT STATION
128 E104 ELEC LIGHTNING PROTECTION PLAN
129 E200 ELECTRICAL OVERALL LIGHTING RCP
130 E201 ELEC ENLARGED RCP - ADMIN WING
131 E202 ELEC ENLARGED RCP - AUDITORIUM/EXHIBIT
132 E203 ELEC ENLARGED RCP - COMFORT STATION
133 E300 ELECTRICAL ONE-LINE DIAGRAM
134 E400 ELECTRICAL SCHEDULES
135 E401 ELECTRICAL PANEL SCHEDULES
136 E402 ELECTRICAL LIGHTING SCHEDULES
137 E403 ELECTRICAL LIGHTING CONTROL SCHEDULES
138 E404 ELECTRICAL LIGHTING CONTROL SCHEDULES
139 E405 ELEC LIGHTNING PROTECTION DETAILS
TECHNOLOGY
140 T000 TECHNOLOGY COVER SHEET
141 T001 TECHNOLOGY RESPONSIBLITY MATRIX
142 TD002 TECHNOLOGY SITE DEMOLITION PLAN
143 T002 TECHNOLOGY SITE PLAN
144 T101 TECHNOLOGY SITE PLAN ENLARGED
145 TD102 TECHNOLOGY DEMOLITION PLAN - ADMIN WING
146 TD103 TECHNOLOGY DEMOLITION PLAN - LOBBY/AUDITORIUM
147 TD200 TECHNOLOGY ENLARGED DEMOLITION - RACK LOCATIONS
148 T201 TECHNOLOGY ENLARGED PLAN - ADMIN WING
149 T202 TECHNOLOGY ENLARGED PLAN - AUDITORIUM/EXHIBIT
150 T203 TECHNOLOGY ENLARGED PLAN - COMFORT STATION
151 T301 TECHNOLOGY RCP - ADMIN WING
152 T302 TECHNOLOGY RCP - AUDITORIUM/EXHIBIT
153 T303 TECHNOLOGY RCP - COMFORT STATION
154 T400 TECHNOLOGY ENLARGED - RACK LOCATION
155 T401 TECHNOLOGY ENLARGED - RACK ELEVATIONS
156 T500 AV ONE-LINES
157 T501 AV ONE-LINES
158 T600 TECHNOLOGY DETAILS
159 T601 TECHNOLOGY DETAILS
160 T602 TECHNOLOGY DETAILS
161 T700 TECHNOLOGY SCHEDULES
FIRE PROTECTION
162 FP001 SYMBOL LIST AND GENERAL NOTES - FIRE PROTECTION
163 FP090 SITE PLAN - FIRE PROTECTION
164 FP101 OVERALL REFLECTED CEILING PLAN - FIRE PROTECTION
165 FP401 ENLARGED PLAN - ADMIN - FIRE PROTECTION
166 FP402 ENLARGED PLAN - AUDITORIUM & EXHIBIT - FIRE PROTECTION
167 FP403 ENLARGED PLAN - COMFORT STATION - FIRE PROTECTION
168 FP501 SECTIONS - FIRE PROTECTION
169 FP601 ADMIN SERVER ROOM - FIRE PROTECTION
170 FP701 DETAILS - FIRE PROTECTION
FIRE ALARM
171 FA001 SYMBOL LIST AND GENERAL NOTES - FIRE ALARM
172 FAD101 OVERALL DEMO FLOOR PLAN - FIRE ALARM
173 FA101 OVERALL FLOOR PLAN - FIRE ALARM
174 FA401 ENLARGED PLAN - ADMIN - FIRE ALARM
175 FA402 ENLARGED PLAN - AUDITORIUM & EXHIBIT - FIRE ALARM
176 FA403 ENLARGED PLAN - COMFORT STATION - FIRE ALARM
177 FA701 DETAILS - FIRE ALARM
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN.
THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LAYOUT AND COORDINATION OF DIMENSIONS IN THE FIELD THAT
ESTABLISH WORK POINTS FOR THEIR WORK AND VARIOUS TRADES.
“ALIGN” AS USED IN THESE DOCUMENTS SHALL MEAN TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE.
ALL DIMENSIONS ARE TO FACE OF <N> STRUCTURE WHERE INTERFACING WITH <N> FRAMING AND TO FACE OF FINISH
WHERE INTERFACING WITH <E> WALLS, UON.
ALL WORK TO BE PERFORMED TO APPLICABLE BUILDING CODES (SEE CODE SUMMARY ON SHEET G003 FOR LIST OF
APPLICABLE CODES).
TYPICAL (TYP) OR SIMILAR (SIM) NOTATION USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITIONS ARE THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS, UNLESS NOTED OTHERWISE. ACTUAL CONDITIONS MAY VARY, BUT DO NOT REVOKE THE INTENT OF THE CONFIGURATION INDICATED. DETAILS ARE USUALLY KEYED AND NOTED “TYPICAL” OR “SIMILAR” ONLY ONCE WITH THE FIRST OCCURRENCE AND ARE REPRESENTATIVE FOR ALL SIMILAR CONDITIONS
THROUGHOUT, UNLESS NOTED OTHERWISE.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH THE CONTRACT DOCUMENTS, VERIFYING FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. CONTRACTOR SHALL NOTIFY C.O. IN WRITING OF ANY DISCREPANCY WITHIN THE CONTRACT DOCUMENTS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.
SHOULD THERE BE ANY QUESTIONS CONCERNING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE C.O. PRIOR TO
PROCEEDING WITH THE WORK, OR RELATED WORK IN QUESTION.
THE CONTRACT DOCUMENTS IN THEIR ENTIRETY ARE THE RESPONSIBILITY OF ALL TRADES. WHERE REQUIREMENTS ARE SHOWN IN ONE SECTION OF THE SPECIFICATIONS OR DRAWINGS BUT NOT ANOTHER, THE CONTRACTOR IS NOT RELIEVED
FROM PROVIDING COMPLETELY FINISHED AND PROPERLY FUNCTIONING SYSTEMS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH THE PROJECT SCOPE OF WORK, SCHEDULE, AND DEADLINES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADVISING THE C.O. OF ALL ITEMS REQUIRING A LONG LEAD TIME UPON NOTICE TO PROCEED THAT WILL AFFECT THE SCHEDULE, AND SHALL SUBMIT ORDER CONFIRMATIONS AND
DELIVERY DATES FOR THE ITEMS IN QUESTION TO THE C.O.
INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT WHERE THE CONTRACT DOCUMENTS ARE MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. THE CONTRACTOR SHALL FURNISH TO THE C.O. ALL WARRANTIES AND
GUARANTEES REQUIRED AT THE CONCLUSION OF THE PROJECT.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HOOK UPS / UTILITY CONNECTIONS, ETC. TO TEMPORARY TRAILERS.
THE CONSTRUCTION SITE IS TO BE KEPT CLEAN AND FREE OF DEBRIS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PHASES
OF SECURING, HANDLING, TRANSPORTING, AND DISPOSING OF DEBRIS.
THE CONTRACTOR SHALL NOT SHUT OFF OR INTERRUPT ANY SYSTEMS OR SERVICES WITHOUT FIRST COORDINATING WITH
THE C.O.
THE CONTRACTOR SHALL COORDINATE WITH THE C.O. TO IDENTIFY AND PROTECT EXISTING STRUCTURE, SYSTEMS, UTILITIES, SURFACES, AND FINISHES WHICH ARE TO REMAIN. ALL SYSTEMS DAMAGED DURING CONSTRUCTION ARE TO BE
REPAIRED BY THE CONTRACTOR AT THEIR EXPENSE.
ROOM
250 SF
A###
A#.#FIRST FLOOR
100'-0"
KEY NOTE
ELEVATION MARK
NORTH ARROWDETAIL REFERENCE
BUILDING
SECTION
ROOM TAG
SYMBOLS & GRAPHICS LEGEND
BLD
G.
NORTH
BUILDING
NORTH ARROW
X
WINDOW TAG WALL TAG DOOR TAG CEILING TAG
A101
RE:1
CALLOUT VIEW
MARK
A2??
1 A4??
EXTERIOR
ELEVATION
MATERIAL TAG
GRID MARK
R-2
OCCUPANCY
TYPE TAG
X#
TYPICAL NEW
CONSTRUCTION UON
TYPICAL EXISTING
TO REMAIN UON
A5.0
SECTION
DETAIL
INTERIOR
ELEVATION
C##
HISTORIC CONTEXT
CONTEXT: THIS BUILDING IS ELIGIBLE FOR LISTING ON THE NATIONAL REGISTER OF HISTORIC PLACES AS AN EXAMPLE OF HISTORIC MISSION 66 ARCHITECTURE. THE SECRETARY OF THE INTERIOR STANDARDS FOR THE TREATMENT OF HISTORIC PROPERTIES HAVE BEEN INTEGRATED INTO THE DESIGN. CHARACTER DEFINING FEATURES, LISTED BELOW, ARE TO BE CAREFULLY PROTECTED AND TREATED PER THOSE STANDARDS. THE BUILDING CONSISTS OF THREE "NODES" CONNECTED BY BOTH INTERNAL AND EXTERNAL WALKWAYS. NODE 1 IS THE ADMINISTRATIVE WING (ADMIN WING) AND HOUSES OFFICES AND SUPPORT SPACES FOR PARK OPERATIONS. CONNECTED BY AN INTERIOR WALKWAY IS NODE 2 (VISITOR CENTER) WHERE EXHIBITS, MERCHANDISING, AND AN AUDITORIUM ARE LOCATED. NODE 3 (COMFORT STATION) IS CONNECTED VIA AN EXTERIOR COVERED WALKWAY AND CONSISTS OF
A WOMEN'S RESTROOM, MEN'S RESTROOM, AND UTILITY/MECHANICAL SPACE.
YEAR BUILT: 1968-1969 (AUDITORIUM ADDITION 1989, ADDITION TO COMFORT STATION 1999)
ORIGINAL ARCHITECT: ROBERT D. NEWCOMB
PERIOD OF SIGNIFICANCE: 1968-1969
TREATMENT PROPOSED: REHABILITATION
CHARACTER DEFINING FEATURES:
VERTICAL STEEL AND WOOD CLAD COLUMNS AT THE CORNERS OF THE ADMIN WING, LOBBY, AND COVERED WALKWAY THAT
MIMIC THE SURROUNDING LODGEPOLE PINE FOREST
INVERTED CORNERS OF THE LOBBY CLAD IN NATIVE STONE
GLASS CURTAIN WALLS AND VISUAL TRANSPARENCY THROUGH THE LOBBY AND INFORMATION CORRIDOR THAT INTEGRATE
THE INTERIOR SPACE AND THE EXTERIOR LANDSCAPE
USE OF WOOD AND NATURAL STONE THAT RELATE TO THE NATURAL ENVIRONMENT AND T1-11 PLYWOOD SIDING THAT IS
CHARACTERISTIC OF THE PERIOD
BROAD, WINDOWLESS STONE WALL AT WEST END OF THE OFFICE WING THAT IS CHARACTERISTIC OF PARK SERVICE MODERN
STYLE ARCHITECTURE
FLAT ROOFS AND OPEN WEB JOIST SYSTEM ROOFS THAT CONTRAST THE VERTICALITY OF THE COLUMNS AND EMPHASIZE
THE SENSE OF SHELTER
ALTHOUGH NO LONGER INTACT, MUCH OF THE EXTERIOR WOOD SURFACES OF ALL COMPONENT BUILDINGS AND CORRIDORS AND THE INTERIOR OF THE LOBBY WERE FINISHED WITH TRANSLUCENT STAIN THAT CONVEYED THE NATURAL APPEARANCE
OF THE WOOD. THESE HAVE SINCE BEEN PAINTED.
THE WING LAYOUT OF INDIVIDUAL COMPONENT BUILDINGS FOR DESIGNATED USES (I.E., ADMINISTRATION IN THE OFFICE WING, VISITOR ORIENTATION IN THE LOBBY, AND SERVICES IN THE COMFORT STATION) THAT ARE CONNECTED WITH
VISUALLY TRANSPARENT CORRIDORS
INTEGRATED INTERIOR AND EXTERIOR SPACES WITH THE COVERED WALK, TERRACE AND PATIO, BENCH SEATING, AND
MEANDERING ROCK-LINED STREAM
MISSION 66 ERA WOOD POST AND BEAM LIGHT POLES WITH GLOBE LIGHTS IN THE PARKING LOT LOW BENCHES FROM THE MISSION 66 ERA THAT ARE INTEGRATED IN THE COVERED WALK AND ARE FREESTANDING ALONG
THE EAST SIDE OF THE PARKING LOT AND SIDEWALK
SOURCE:
KAWUNEECHE VISITOR CENTER ARCHITECTURAL INVENTORY FORM, 2022 (RESOURCE NUMBER: 5GA.1285 )
1989 AUDITORIUM
ADDITION
1999 COMFORT
STATION ADDITION
WITH <N> GABLE ROOF
ADMIN WING
VISITOR
CENTER
COMFORT
STATIONNODE 3
NODE 1
NODE 2
OPTIONS:
OPTION 1: CUSTOM STEEL WINDOW: PROVIDE <N> CUSTOM STEEL WINDOWS FOR WINDOW TYPE A1 AND A2 IN ALL LOCATIONS INDICATED INSTEAD OF ALUMINUM WINDOWS INCLUDED IN THE BASE SCOPE. <N> CUSTOM STEEL WINDOWS SHALL BE THERMALLY BROKEN, DOUBLE PANE WITH CLEAR LOW-E COATING. WINDOW OPERATION SHALL MATCH <E>: EQUALLY SPLIT WITH SLIDER, INCLUDING EXTERIOR SCREEN. SASH PROFILES TO MATCH <E> AND APPROVED BY C.O. THROUGH SHOP DRAWINGS AND FULL
MOCK-UP OF ONE A1 TYPE UNIT.
# POUND(S) or NUMBER
& AND
< ANGLE
@ AT
A/V AUDIO VISUAL
ABAAS AMERICAN BARRIERS ACT ACCESSIBILITY
STANDARDS
ABV ABOVE
ACM ASBESTOS CONTAINING MATERIAL
ACT ACCOUSTICAL CEILING TILE
ADD ADDENDUM
ADJ ADJACENT or ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
APPROX APPROXIMATE(LY)
ARCH ARCHITECTURAL
ASPH ASPHALT
B.O. BOTTOM OF
BLDG BUILDING
BLKG BLOCKING
BOD BASIS OF DESIGN
BR BACKER ROD
BTWN BETWEEN
C.O. CONTRACTING OFFICER
CAB CABINET
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLOS CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTBB CEMENTITIOUS TILE BACKER BOARD
CTR CENTER
DBL DOUBLE
DEMO DEMOLITION
DET DETAIL
DF DRINKING FOUNTAIN
DIAM DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
<E> EXISTING
E EAST
EA EACH
EG FOR EXAMPLE
ELEC ELECTRICAL
ELEV ELEVATION
EMER EMERGENCY
ENGR ENGINEER
EQ EQUAL
EQP EQUIPMENT
ABBREVIATIONS
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:0
0 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
G002
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 3 177
GENERAL INFO &
ABBREVIATIONS
ETR EXISTING TO REMAIN
EXT EXTERIOR
FACP FIRE ALARM CONTROL PANEL
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FURNITURE, FIXTURES, & EQUIPMENT
FIN FINISH(ED)
FIXT FIXTURE
FLR FLOOR(ING)
FO FACE OF
FP FIRE PROTECTION
FRP FIBERGLASS REINFORCED PANEL(ING)
FT FEET
FTG FOOTING
FURR FURRING
GA GAUGE OR GYPSUM ASSOCIATION
GALV GALVANIZED
GC GENERAL CONTRACTOR
GD GRADE
GL GLASS or GLAZING
GND GROUND
GWB GYPSUM WALLBOARD
HM HOLLOW METAL
HAZMAT HAZARDOUS MATERIAL
HD HIGH-DENSITY
HDR HEADER
HDW HARDWARE
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATION and AIR
CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
INFO INFORMATION
INS INSULATION or INSULATED
INT INTERIOR
JT JOINT
LAV LAVATORY
LIN LINOLEUM
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL and
PLUMBING
MFG MANUFACTURING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
<N> NEW
N NORTH
NA NOT APPLICABLE
NH NON-HALOGENATED
NIC NOT IN CONTRACT
NO. NUMBER
NOAA NATIONAL OCEANIC AND ATMOSPHERIC
ADMINISTRATION
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PT PAINT
PTD PAINTED
PWD PLYWOOD
QT QUARRY TILE
RAD RADIUS
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE: REFER TO or REFERENCE
REINF REINFORCED
RELOC RELOCATE(D)
REQ REQUIRED
REV REVISE, REVISED or REVISION
RM ROOM
RO ROUGH OPENING
RS ROUGH SAWN
(S) SEALANT
S SOUTH
SCHED SCHEDULE
SF SQUARE FEET
SHTG SHEATHING
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STF STOREFRONT
STL STEEL
STN STAIN
STRUC STRUCTURE or STRUCTURAL
(T) TEMPERED
T&G TONGUE AND GROOVE
T.O. TOP OF
TD THRESHOLD
TECH TECHNOLOGY
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VIN VINYL
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
W WEST
W/ WITH
W/O WITHOUT
WD WOOD
WIN WINDOW
SCALE
FOOTPRINT/ADDITIONS
DIAGRAM
A
40 84
SCALE OF FEET
G002
ADDRESS: 16018 US 34, GRAND LAKE, CO 80447
AHJ: NATIONAL PARK SERVICE, DENVER SERVICE CENTER
THE BUILDING CONSISTS OF THREE "NODES" CONNECTED BY BOTH INTERNAL AND EXTERNAL COVERED WALKWAYS.
NODE 1 IS THE ADMINISTRATIVE WING (ADMIN WING) AND HOUSES OFFICES AND SUPPORT SPACES FOR PARK OPERATIONS. CONNECTED BY AN INTERIOR WALKWAY IS NODE 2 (VISITOR CENTER) WHERE EXHIBITS, MERCHANDISING, AND AN AUDITORIUM ARE LOCATED. NODE 3 (COMFORT STATION) IS CONNECTED VIA AN EXTERIOR CANOPY AND CONSISTS OF A WOMEN'S RESTROOM, MEN'S RESTROOM, AND UTILITY/MECHANICAL SPACE. ALL NODES AND
CONNECTING CANOPY ARE CONSIDERED ONE BUILDING.
APPLICABLE CODES AND STANDARDS
2024 INTERNATIONAL BUILDING CODE (IBC)
2024 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
2024 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2024 INTERNATIONAL WILDLAND URBAN INTERFACE CODE (WUIC)
SECRETARY OF THE INTERIOR STANDARDS FOR THE TREATMENT OF HISTORIC PROPERTIES FOR REHABILITATION
ASHRAE 90.1 – 2013
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS)
2017 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
DIRECTOR'S ORDER 58 & REFERENCE MANUAL 58: STRUCTURAL FIRE MANAGEMENT
REFER TO INDIVIDUAL DISCIPLINE SHEETS FOR ADDITIONAL CODE INFO
IEBC CLASSIFICATION
ALTERATION LEVEL 3 PER IEBC §604 WORK AREA METHOD
THE WORK INCLUDES ACCESSIBILITY UPGRADES, NEW INTERIOR FINISHES, DOORS AND WINDOWS, PAINT AND STAIN, SIGNAGE, ELECTRICAL, PLUMBING, AND MECHANICAL AND TECHNOLOGY UPGRADES, AND THE INSTALLATION OF A NEW
FIRE SUPPRESSION SYSTEM. THE WORK AREA EXCEEDS 50% OF THE BUILDING AREA.
ALL NEW CONSTRUCTION SHALL COMPLY WITH IBC.
USE & OCCUPANCY CLASSIFICATION - IBC CHAPTER 3
THE BUILDING CONTAINS MULTIPLE EXISTING USES & CLASSIFICATIONS (TO REMAIN):
A-3 ASSEMBLY (AUDITORIUM & EXHIBIT) PER IBC § 303.4
B BUSINESS (OFFICES AND ADMIN FUNCTIONS) PER IBC § 304.1
STORAGE AREAS ARE CONSIDERED ACCESSORY PER IBC § 311.1.1
REFER TO SHEET G004 FOR CODE & ACCESSIBILITY PLAN.
GENERAL BUILDING HEIGHTS & AREAS - IBC CHAPTER 5
BUILDING HEIGHT §504. PROJECT REDUCES MAXIMUM BUILDING HEIGHT FROM +/- 19'-1" TO +/- 15'-8".
ALLOWABLE BUILDING HEIGHT (TABLE 504.3), AND NUMBER OF STORIES (TABLE 504.4)
ALLOWABLE BUILDING AREA (TABLE 506.2)
*EXTERIOR COVERED WALKWAY NOT INCLUDED IN AREA
NON-SEPARATED OCCUPANCIES - IBC §508.3.2
PROJECT SHALL UTILIZE MOST RESTRICTIVE OCCUPANCY (A-3) MAXIMUM ON ALLOWABLE BUILDING AREA, HEIGHT AND
NUMBER OF STORIES.
TYPES OF CONSTRUCTION - CHAPTER 6
CONSTRUCTION CLASSIFICATION: VB PER IBC §602.2
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) PER TABLE 601
FIRE AND SMOKE PROTECTION FEATURES - CHAPTER 7
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXT WALLS BASED ON FIRE SEPARATION DISTANCE (TABLE 705.5)
THE PROPOSED WORK COMPLIES WITH TABLE 705.9 OPENINGS. THERE ARE NO OTHER STRUCTURES WITHIN 30 ’ OF THE
BUILDING AND THEREFORE THERE IS NO LIMIT TO THE NUMBER OF UNPROTECTED OPENINGS.
FIRE PROTECTIVE SYSTEMS - CHAPTER 9
AUTOMATIC SPRINKLER SYSTEM NOT REQUIRED, BUT WILL BE PROVIDED THROUGHOUT THE BUILDING PER NPS
DIRECTOR'S ORDER 58 AND NFPA 13. REFER TO FIRE PROTECTION DRAWINGS.
PORTABLE FIRE EXTINGUISHERS TO BE PROVIDED PER IBC §906
PROVIDE CLASS A FIRE HAZARD (ORDINARY HAZARD OCCUPANCY) PORTABLE FIRE EXTINGUISHERS.
PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN CONSPICUOUS LOCATIONS ALONG NORMAL PATHS
OF TRAVEL. AND SHALL NOT BE OBSTRUCTED OR OBSCURED FROM VIEW.
MAXIMUM TRAVEL DISTANCE TO ANY FIRE EXTINGUISHER SHALL BE 75 FEET MAX AND 11,250 SF MAX FLOOR
AREA PER TABLE 906.3(1)
REFER TO G004 FOR LOCATIONS
FIRE ALARM AND DETECTION SYSTEMS TO BE PROVIDED PER §907. REFER TO FIRE ALARM DRAWINGS.
MEANS OF EGRESS - CHAPTER 10
REFER TO SHEET G004 FOR CODE & ACCESSIBILITY PLAN.
HEADROOM - IBC §1003.2
80" MINIMUM OVER ANY WALKING SURFACE.
INTERVENING SPACES OR ACCESSORY AREAS - IBC §1004.2.1
WHERE OCCUPANTS EGRESS FROM ONE OR MORE ROOMS THROUGH OTHERS, THE DESIGN OCCUPANT LOAD SHALL BE THE COMBINED OCCUPANT LOAD OF INTERCONNECTED ACCESSORY OR INTERVENING SPACES. DESIGN OF EGRESS PATH CAPACITY SHALL BE BASED ON THE CUMULATIVE PORTION OF OCCUPANT LOADS OF ALL ROOMS TO
THAT POINT ALONG THE PATH OF EGRESS TRAVEL.
MULTIPLE OCCUPANCIES - IBC §1004.4
WHERE A BUILDING CONTAINS TWO OR MORE OCCUPANCIES, THE MEANS OF EGRESS REQUIREMENTS SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE OCCUPANCY OF THAT SPACE. WHERE TWO OR MORE OCCUPANCIES UTILIZE PORTIONS OF THE SAME MEANS OF EGRESS SYSTEMS, THOSE EGRESS COMPONENTS SHALL
MEET THE MORE STRINGENT REQUIREMENTS OF ALL OCCUPANCIES THAT ARE SERVED.
DESIGN OCCUPANT LOAD - TABLE 1004.5
MEANS OF EGRESS SIZING - IBC §1005
WHERE MULTIPLE MEANS OF EGRESS ARE REQUIRED, THEY SHALL BE SIZED SUCH THAT IN THE EVENT ONE OF THE MEANS OF EGRESS IS LOST, THEN THE REMAINING MEANS OF EGRESS SHALL NOT REDUCE THE AVAILABLE
CAPACITY TO LESS THAN 50 PERCENT OF THE REQUIRED CAPACITY.
EGRESS COMPONENT WIDTHS PER §1005.3.2
* DEFAULTS TO CODE MINIMUM OF 32" FOR DOORS PER §1010.1, AND 44" FOR CORRIDORS PER TABLE 1020.3.
MAXIMUM COMMON PATH OF TRAVEL DISTANCE - TABLE 1006.2.1
MAXIMUM COMMON PATH OF TRAVEL (SPRINKLERED):
MAX ALLOWED MAX PROVIDED
OCCUPANCY A-3:
AUDITORIUM / EXHIBIT 75' 21'-9"
NUMBER OF EXITS - IBC §1006.3.3
OCCUPANT REQ # PROVIDED
LOAD OF EXITS # OF EXITS
OCCUPANCY A-3:
AUDITORIUM / EXHIBIT 116 2 3
OCCUPANCY B:
ADMIN WING 33 1 1
SINGLE EXITS - IBC §1006.3.4
A SINGLE EXIT SHALL BE PERMITTED FROM ANY STORY WHERE ROOMS COMPLYING WITH §1006.2.1 WITH EXITS THAT
DISCHARGE DIRECTLY TO THE EXTERIOR AT THE LEVEL OF EXIT DISCHARGE.
REFER TO ELECTRICAL DRAWINGS FOR <N> EXIT SIGNAGE AND MEANS OF EGRESS LIGHTING.
PANIC HARDWARE PROVIDED ON EGRESS DOORS.
EXIT AND EXIT ACCESS DOORWAY CONFIGURATION - IBC §1007
WHERE TWO EXITS ARE REQUIRED, THEY SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED
MEASURED IN A STRAIGHT LINE BETWEEN THEM.
OCCUPANCY A-3, AUDITORIUM / EXHIBIT:
REQUIRED MIN EXIT SEPARATION DISTANCE: 88'-3 1/4" / 3 = 26'-7"
EXIT SEPARATION PROVIDED: 36'-0 3/4"
ACCESSIBLE MEANS OF EGRESS - IBC §1009
ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS PER SECTION 1009.1.
ACCESSIBLE MEANS OF EGRESS PROVIDED = 5
CONTINUITY - IBC §1009.2
EACH REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE CONTINUOUS TO A PUBLIC WAY
FLOOR ELEVATION - §1010.1.5
THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR, EXCEPT THAT DOORS SERVING EQUIPMENT SPACES ARE NOT REQUIRED TO BE ACCESSIBLE IN ACCORDANCE WITH §1103.2.9 AND SERVING AN OCCUPANT LOAD OF 5 OR LESS SHALL BE PERMITTED TO HAVE A FLOOR ON ONE SIDE TO BE NOT MORE THAN 7 INCHES ABOVE OR
BELOW THE LANDING ON THE EGRESS SIDE OF THE DOOR.
POWER OPERATED DOORS - §1010.3.2
WHERE MEANS OF EGRESS DOORS ARE OPERATED OR ASSISTED BY POWER, THE DESIGN SHALL BE SUCH THAT IN THE EVENT OF POWER FAILURE, THE DOOR IS CAPABLE OF BEING OPENED MANUALLY TO PERMIT MEANS OF EGRESS
TRAVEL OR CLOSED WHERE NECESSARY TO SAFEGUARD MEANS OF EGRESS.
PER NPS DSC ACCESSIBILITY AND UNIVERSAL DESIGN STANDARDS, INTERIOR DOORS ON AN ACCESSIBLE ROUTE WHICH CANNOT MEET ABAAS SECTION 404 REQUIREMENTS SHALL HAVE POWER ASSISTED OPENERS. ONE DOOR IN THE PROJECT DOES NOT MEET ABAAS SECTION 404 FOR REQUIRED APPROACH CLEARANCES. DOOR TO ADMIN STAFF RESTROOM 113 IS REQUIRED TO HAVE POWER ASSISTED OPENERS. PER ABAAS SECTION 404.3, THE POWERED OPENERS MUST HOLD THE DOORS IN THE FULLY OPEN POSITION IN THE EVENT OF A POWER OUTAGE.
EGRESS THROUGH INTERVENING SPACES - §1016.2
EGRESS FROM A ROOM OR SPACE IS ALLOWED TO PASS THROUGH ADJOINING ROOMS PROVIDED THAT SUCH ADJOINING ROOMS AND THE AREA SERVED ARE ACCESSORY TO ONE OR THE OTHER AND PROVIDE A DISCERNABLE
PATH OF EGRESS TRAVEL TO AN EXIT.
EXIT ACCESS TRAVEL DISTANCE - TABLE 1017.2
MAXIMUM EXIT TRAVEL DISTANCE (SPRINKLERED):
MAX ALLOWED MAX PROVIDED
OCCUPANCY A-3:
AUDITORIUM / EXHIBIT 250' 89'-3"
OCCUPANCY B:
ADMIN WING 300' 66'-2"
ACCESSIBILITY - CHAPTER 11
ACCESSIBLE ROUTE PER IBC §1104
ACCESSIBLE ENTRANCES - IBC §1105.1
PUBLIC ENTRANCES: AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL BE ACCESSIBLE. TWO ACCESSIBLE
PUBLIC ENTRIES PROVIDED, RE: G004 CODE & ACCESSIBILITY PLAN.
SIGNAGE - IBC §1112
SIGNS: REQUIRED ACCESSIBLE ELEMENTS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY
AT THE LOCATIONS LISTED IN §1112.1.
GENERAL ACCESSIBILITY NOTES
THE DETAILS AND NOTES PROVIDED WITHIN THESE DOCUMENTS REPRESENT ONLY A PORTION OF THE REQUIREMENTS SET FORTH BY FEDERAL LAW AND THE BUILDING CODE FOR ACCESSIBILITY REQUIREMENTS.
CONTRACTORS MUST REVIEW ALL ACCESSIBILITY REQUIREMENTS AS PRESENTED IN THESE CONSTRUCTION
DOCUMENTS AND THE REFERENCES HEREIN PRIOR TO STARTING ANY CONSTRUCTION.
FOR SITE ACCESSIBILITY REQUIREMENTS AND ALL SITE ACCESSIBILITY DETAILING, RE: CIVIL.
TOTAL
OCC.
WIDTH
FACTOR
0.15" PER OCC.
(SPRINKLERED)149
CAPACITY
REQUIRED
CAPACITY
PROVIDED
22.4" * 34"
EGRESS
COMPONENT
DOORS
CORRIDORS +/- 61"
A-3, B OCCUPANCY
ALLOWABLE
60'
2 STORIES
BUILDING HEIGHT
NUMBER OF STORIES
ACTUAL
+/- 15'-8"
1 STORY
VB CONSTRUCTION TYPE (SPRINKLERED)
OCCUPANCY GROUP(S) &
CONSTRUCTION TYPE
ALLOWABLE AREA
A-3, B; TYPE VB 24,000 SF
(SPRINKLERED)
ACTUAL AREA
2,581 SF (ADMIN WING)
4,938 SF * TOTAL AREA
1,895 SF (VISITOR CENTER)
462 SF (COMFORT STATION)
BUILDING ELEMENT
PRIMARY STRUCTURAL FRAME
TYPE VB
REQUIRED
PROVIDED
BEARING WALLS
EXTERIOR
INTERIOR
NONBEARING WALLS AND PARTITIONS, EXT Re: Table 705.5 NA
NONBEARING WALLS AND PARTITIONS, INT 0 0
ROOF CONSTRUCTION & SECONDARY MEMBERS 0 0
FLOOR CONSTRUCTION & SECONDARY MEMBERS 0 0
X < 5 b 1
TYPE OF CONSTRUCTIONFIRE SEPARATION DISTANCE = X (feet)
ALL
REQUIRED PROVIDED
NA
5 ≤ X < 10 1
IA, IVA
OTHERS
NA
NA
10 ≤ X < 30
IA, IB
IIB, VB
OTHERS
NA
NA
NA
X ≥ 30 0ALL 0
1.
2.
3.
1.
2.
3.
PLUMBING FIXTURES - CHAPTER 29
§2902.1 - MINIMUM NUMBER OF FIXTURES SHALL BE PROVIDED FOR THE TYPE OF OCCUPANCY AND IN THE MINIMUM
NUMBERS PER TABLE 2902.1
PLUMBING FIXTURE COUNT PER OCCUPANT LOAD, TABLE 2902.1
ASSEMBLY 116
BUSINESS 33
ASSEMBLY OCCUPANCY:
(116 TOTAL GROUP A OCCUPANTS; 58 MALE, 58 FEMALE)
WATER CLOSETS:
*MALE: 1 PER 125 = .51 REQUIRED, 2 PROVIDED AND 3 URINALS
*FEMALE: 1 PER 65 = .94 REQUIRED, 5 PROVIDED
LAVATORIES:
MALE: 1 PER 200 = .29 REQUIRED, 3 PROVIDED
FEMALE: 1 PER 200 = .29 REQUIRED, 3 PROVIDED
BUSINESS OCCUPANCY:
(33 TOTAL GROUP B OCCUPANTS; 17 MALE, 17 FEMALE)
WATER CLOSETS:
*MALE: 1 PER 25 = .7 REQUIRED, 1 PROVIDED
*FEMALE: 1 PER 25 = .7 REQUIRED, 1 PROVIDED
LAVATORIES:
MALE: 1 PER 40 = .43 REQUIRED, 1 PROVIDED
FEMALE: 1 PER 40 = .43 REQUIRED, 1 PROVIDED
* SINGLE USER RESTROOMS: 2024 IPC FOR B OCCUPANCIES DOES NOT DISTINGUISH A FIXTURE REQUIREMENT DIFFERENCE BETWEEN MALE AND FEMALE, PERMITTING THE USE OF GENDER NEUTRAL RESTROOMS FOR FULFILLMENT
OF FIXTURE REQUIREMENTS.
DRINKING FOUNTAINS:
1 REQUIRED, 4 DRINKING FOUNTAINS PROVIDED (TWO ACCESSIBLE W/ BOTTLE FILLER)
1 SERVICE SINK REQUIRED; 2 SERVICE SINKS PROVIDED
2024 INTERNATIONAL WILDLAND URBAN INTERFACE CODE
THE BUILDING IS LOCATED WITHIN A WUI INTERMIX ZONE. CLASS I IGNITION RESISTANT CONSTRUCTION AND MATERIALS SHALL BE UTILIZED FOR NEW EXTERIOR BUILDING MATERIALS AND ELEMENTS, PER §503 THROUGH §506.
FIRE APPARATUS ACCESS IS TO BE PROVIDED IN COMPLIANCE WITH §403.
WATER SUPPLY TO BE PROVIDED IN COMPLIANCE WITH §404.
WHERE POSSIBLE, PROVIDE FOR DEFENSIBLE SPACE REQUIREMENTS PER §603. REFER TO CIVIL DRAWINGS, AND
COORDINATE WITH PARK FOR ALL VEGETATION AND TREES TO BE REMOVED.
DEFENSIBLE SPACE
THE FUEL MODIFICATION DISTANCE WITHIN THE DEFENSIBLE SPACE SHALL BE NOT LESS THAN 30 FEET
FROM BUILDINGS AND STRUCTURES.
TO BE CONSIDERED A FUEL MODIFICATION AREA, CONTINUOUS MAINTENANCE OF THE CLEARANCE IS
REQUIRED.
TREES ARE ALLOWED WITHIN THE DEFENSIBLE SPACE PROVIDED THAT HORIZONTAL DISTANCES BETWEEN
CROWNS OF ADJACENT TREES AND CROWNS OF TREES AND STRUCTURES OVERHEAD ELECTRICAL
FACILITIES OR UNMODIFIED FUEL IS NOT LESS THAN 10 FEET.
MAINTENANCE OF DEFENSIBLE SPACE
DEADWOOD AND LITTER SHALL BE REGULARLY REMOVED FROM TREES.
TREE CROWNS EXTENDING TO WITHIN 10 FEET OF ANY STRUCTURE SHALL BE PRUNED TO MAINTAIN A MINIMUM HORIZONTAL CLEARANCE OF 10 FEET. TREE CROWNS WITHIN THE DEFENSIBLE SPACE SHALL BE PRUNED TO REMOVE LIMBS LOCATED LESS THAN 6 FEET ABOVE THE GROUND SURFACE ADJACENT TO THE
TREES.
GROUNDCOVERS SUCH AS GREEN GRASSES ARE ALLOWED TO BE WITHIN THE DESIGNATED DEFENSIBLE SPACE PROVIDED THAT THEY DO NOT FORM A MEANS OF TRANSMITTING FIRE FROM THE NATIVE GROWTH
TO ANY STRUCTURE.
CODE ANALYSIS
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:0
0 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
G003
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 4 177
CODE ANALYSIS
OCCUPANT LOAD
OCC
CLASS AREA ROOM NAME(S) OCC FUNCTION
OCC LOAD
FACTOR
# OF
OCC
A-3 1,033 SF AUDITORIUM ASSEMBLY, UNCONCENTRATED 15 SF 69
A-3 1,367 SF EXHIBIT 1 & 2 ASSEMBLY, EXHIBIT 30 SF 46
A-3 193 SF STOR / CONTROL STORAGE / MECH, ACCESSORY 300 SF 1
B 100 SF STORAGE STORAGE, ACCESSORY 300 SF 1
B 245 SF MECH / ELEC / SERVER EQUIPMENT, ACCESSORY 300 SF 1
B 215 SF BREAK ASSEMBLY, UNCONCENTRATED 15 SF 15
B 2,133 SF CONF. & OFFICES BUSINESS 150 SF 15
B 97 SF COMFORT STATION JAN
/ MECH
EQUIPMENT, ACCESSORY 300 SF 1
BUILDING TOTAL OCCUPANTS 149
III
V
I
IV
VI VII
VIII IX
II
X
II
VI
XIII
VI
XIII
VI
XIII
XIII
XIII
VI
VI
VI
XIII
VII
VI
VI
I
VI
XIV
VI
IX
VI
VI
VII
VI VI
I
VI VI
I
VI
I
VI
V V
X
I
I
I
V
II
V
I
II
VI
IX
III
III
I I
VIII
VII
VIII
VII
VI
VII
I I
VIVI
I
VI
VII
III
I
VI
VII
VI
I
I
VI VI
5'- 0"
WATER CLOSET
CLEARANCE
CIRCLE TURNING SPACE*
ACCESSIBILITY CLEARANCES
4'-4"
2'- 6"
CLEAR FLOOR SPACE T-SHAPED TURNING SPACE
OPT. B
LATCH APPROACH
PUSH SIDE
FRONT APPROACH
PUSH SIDE
FRONT APPROACH
PULL SIDE
LATCH APPROACH
PULL SIDE
3'- 2"
1'-
5'-
0"
11" 3'-6" 11" 5'-4"
4'-8"
1'-6"
DOOR
32" MIN.
4'-6"
5'- 0" 4'- 4"
** 1'-0"
DOOR
32" MIN.
2'-0"
DOOR
32" MIN.
5'-0"
4'- 0"
2'-0"
DOOR
32" MIN.
5'-0"
3'- 6"
ALLOWABLE KNEE & TOE
OVERLAP
5' - 7" 5' - 0
2'- 1"
"-1
8"
SIDE WALL OR
PARTITION
4'-0"
** = SIDE CLEARANCE ONLY
REQUIRED IF BOTH CLOSER
AND LATCH ARE PROVIDED
LATCH APPROACH
TOILET COMPARTMENT
2'-0"
DOOR
32" MIN.
5'-0"
3'- 6"
* 67" TURNING RADIUS PROVIDED
IN MAIL 117 & COMFORT STATION
RESTROOMS
LEGEND
ABAAS EGRESS DOOR
EXIT SIGNAGE, RE: ELEC
ABAAS ROUTE, 36" CLEAR UON
ABAAS DOOR APPROACH DIRECTION
EXIT EGRESS PATH OF TRAVEL
FIRE EXTINGUISHER CABINET
AUTOMATED DOOR OPENER, RE: ELEC
FEC
ADO
BREAK
ROOM
MECH. /
ELEC.RRRR
OFFICEOFFICEOFFICE
OFFICE OFFICE OFFICE
HALL
OFFICE CONFERENCE
WILDERNESS
DESK
EXHIBIT
NO. 1
EXHIBIT
NO. 2
AUDITORIUM
STORAGESTORAGE
VEST.
JC
OCC CLASS:
AREA:
OCC LOAD FACTOR:
OCC LOAD:
1,033
A-3
ASSEMBLY, UNCONCENTRATED
OCC CLASS:
AREA:
OCC LOAD FACTOR:
OCC LOAD:
B
STORAGE, ACCESSORYSTOR
SERVER
ROOM
OFFICE
MEN'S
RR
WOMEN'S
RR
JANITOR
MECH.
RM
OCC CLASS:
AREA:
OCC LOAD FACTOR:
OCC LOAD:
A-3
STORAGE / MECH, ACCESSORY
OCC CLASS:
AREA:
OCC LOAD FACTOR:
OCC LOAD:
1,367
A-3
ASSEMBLY, EXHIBIT
OCC CLASS:
AREA:
OCC LOAD FACTOR:
OCC LOAD:
B
EQUIPMENT, ACCESSORY
MIN. REQ. EXIT SEPARATION: 1/3 x 88'-3 1/4" = 29'-5"
EXIT EGRESS DISTANCE = +/- 88'-3 1/4"
OCC CLASS:
AREA:
OCC LOAD FACTOR:
OCC LOAD:
B
ASSEMBLY, UNCONCENTRATED
OCC CLASS:
AREA:
OCC LOAD FACTOR:
OCC LOAD:
2,133
B
BUSINESS
MAX TRAVEL DISTANCE:
MAX ALLOWABLE:
89' - 3" 250' - 0"
+/- 36'-0 3/4" EXIT SEPARATION DISTANCE
MAX TRAVEL DISTANCE:
MAX ALLOWABLE:
57' - 1"
MAX TRAVEL DISTANCE:
MAX ALLOWABLE:
66' - 2" 300' - 0"
MECH.
RM
FEC
FEC
250' - 0"
MAX ALLOWABLE:
COMMON PATH DISTANCE: 21' - 9"
75' - 0"
ADO
ADO
A D
O
MAX TRAVEL DISTANCE:
MAX ALLOWABLE:
56' - 8" 250' - 0"
NOTE: REFER TO CIVIL DRAWINGS FOR CONTINUATION
OF ACCESSIBLE ROUTE AT BUILDING EXTERIOR
ADO
ADO
OCC CLASS:
AREA:
OCC LOAD FACTOR:
OCC LOAD:
B
EQUIPMENT, ACCESSORY
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
REFER TO CIVIL FOR CONTINUATION OF SITE ACCESSIBILITY.
PER 2017 ICC A117.1 SECTION 304.3.1.2 EXISTING BUILDING AND FACILITIES: IN EXISTING BUILDINGS AND FACILITIES THE TURNING SPACE SHALL BE A CIRCULAR SPACE WITH A 60 INCH MINIMUM DIAMETER.
SEE SHEET G501 FOR ACCESSIBLE MOUNTING HEIGHTS.
CHANGES IN LEVEL GREATER THAN ¼ INCH IN HEIGHT AND NOT MORE THAN ½ INCH MAXIMUM IN HEIGHT
SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2, RE: CIVIL.
CROSS SLOPE NOT TO EXCEED 1.5% ALONG ACCESSIBLE ROUTE, RE: CIVIL.
SLOPE NOT TO EXCEED 1.5% IN ANY DIRECTION AT LANDING OF DOOR, RE: CIVIL.
ALL ACCESSIBLE FIXTURES AND ACCESSORIES SHALL BE MOUNTED IN COMPLIANCE WITH ABAAS.
ALL LAVATORIES SHALL HAVE UNDERLAVATORY PROTECTION UNLESS OTHERWISE PROTECTED.
ALL FAUCETS SHALL BE ANSI CERTIFIED.
EXHIBIT INSTALLATIONS ARE SHOWN FOR REFERENCE IN EXEMPLIFYING ONE POSSIBLE ACCESSIBLE EGRESS ROUTE. MULTIPLE PATHS THROUGH THE SPACE ARE AVAILABLE. EXHIBIT INSTALLATION DESIGN IS OUTSIDE
THE SCOPE OF THIS PROJECT BUT INCLUDED FOR REFERENCE.
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:0
3 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
G004
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 5 177
CODE &
ACCESSIBILITY PLAN
80 168
SCALE OF FEET
SCALEG004 A
CODE & ACCESSIBILITY PLAN1
OCCUPANT LOAD
OCC
CLASS AREA ROOM NAME(S) OCC FUNCTION
OCC LOAD
FACTOR
# OF
OCC
A-3 1,033 SF AUDITORIUM ASSEMBLY, UNCONCENTRATED 15 SF 69
A-3 1,367 SF EXHIBIT 1 & 2 ASSEMBLY, EXHIBIT 30 SF 46
A-3 193 SF STOR / CONTROL STORAGE / MECH, ACCESSORY 300 SF 1
B 100 SF STORAGE STORAGE, ACCESSORY 300 SF 1
B 245 SF MECH / ELEC / SERVER EQUIPMENT, ACCESSORY 300 SF 1
B 215 SF BREAK ASSEMBLY, UNCONCENTRATED 15 SF 15
B 2,133 SF CONF. & OFFICES BUSINESS 150 SF 15
B 97 SF COMFORT STATION JAN
/ MECH
EQUIPMENT, ACCESSORY 300 SF 1
BUILDING TOTAL OCCUPANTS 149
TRUE PLAN
WALL ASSEMBLIES
TYPE # GRAPHIC REPRESENTATION
4 3 /4"
<N> 1/2" GWB, PT
<N> 2X4 WOOD STUDS AT 16" OC
<N> 1/2" GWB, PT
<N> FULL DEPTH ACOUSTIC BATT INSULATION1.0
1.1
7 1 /2"
<N> 5/8" CTBB
<N> 2X6 WOOD STUDS AT 16" OC
<N> 1/4" CERAMIC TILE (RE: FINISH SCHEDULE)
1.2
<N> 5/8" CTBB
<N> 1/4" CERAMIC TILE (RE: FINISH SCHEDULE)
CEILING ASSEMBLIES
TYPE # GRAPHIC REPRESENTATION
C1
<E> ROOF FRAMING TO REMAIN
<N> 1/2" GWB
<N> MINERAL WOOL INSULATION AT
UNDERSIDE OF <E> ROOF FRAMING (R-38 MIN)
<E> ROOF DECK
V.
I.F
VA
RI
ES
C3
<E> ROOF FRAMING TO REMAIN
<N> ACOUSTICAL CEILING TILE, RE: RCP AND FINISH PLAN
<N> HUNG GRID SYSTEM
C2
<E> ROOF FRAMING TO REMAIN
REINSTALL SALVAGED & REFINISHED
HISTORIC 1X6 WOOD CEILING BOARDS
<N> MINERAL WOOL INSULATION AT
UNDERSIDE OF <E> ROOF FRAMING (R-38 MIN)
<E> ROOF DECK
V.
I.F
VA
RI
ES
<N> 1/2" PLYWOOD SUBSTRATE PAINTED
BLACK, RE: STRUCT FOR ATTACHMENT
<N> 2X6 WOOD STUDS AT 16" OC1.3
<N> 5/8" CTBB
<N> 1/4" CERAMIC TILE (RE: FINISH SCHEDULE)
<N> FULL DEPTH BATT INSULATION
<N> MINERAL WOOL INSULATION AT UNDERSIDE
OF <E> ROOF DECK BETWEEN <E> JOISTS
<N> MINERAL WOOL INSULATION AT UNDERSIDE
OF <E> ROOF DECK BETWEEN <E> JOISTS
<N> MINERAL WOOL INSULATION AT
UNDERSIDE OF <E> ROOF FRAMING (R-38 MIN)
<E> ROOF DECK
<N> MINERAL WOOL INSULATION AT UNDERSIDE
OF <E> ROOF DECK BETWEEN <E> JOISTS
<N> FULL DEPTH ACOUSTIC BATT INSULATION
6 3 /4"
<N> 1/2" (MOISTURE RESISTANT) GWB, PT
<N> 2X6 WOOD STUDS AT 16" OC
<N> 1/2" GWB, PT
<N> FULL DEPTH ACOUSTIC BATT INSULATION
1.4
6 1 /2"
R1
<E> ROOF FRAMING TO REMAIN
<N> EPDM ROOFING (CLASS I IGNITION RESISTANCE)
<E> 1X6 WOOD CEILING BOARDS TO REMAIN
<E> 1/2" PLYWOOD SUBSTRATE TO REMAIN
4 3 /4"
<E> 5/8" T1-11 TO REMAIN
<E> 2X4 WOOD STUDS AT 16" OC TO REMAIN
<N> SMART VAPOR RETARDER, PROVIDE CONTINUOUS
SEAL AROUND PERIMETER OF EACH WALL CAVITY
2.1
EXTERIOR
INTERIOR
<N> 1/2" GWB, PT
VISITOR CENTER
AUDITORIUM
<N> 1/2" GWB, PT
<N> 2X4 WOOD STUDS
<N> FULL DEPTH MINERAL BOARD INSULATION
<N> 1/2" NH HD POLYISO COVER BOARD
<N> TAPERED NH POLYISO RIGID INSULATION (R-35
MIN), STAGGER JOINTS, 1/4" MIN SLOPE TO DRAIN
<N> SUBSTRATE SHEATHING, RE: STRUC
<N> VAPOR RETARDER, TAPE ALL JOINTS
ROOF/CEILING ASSEMBLY
TYPE # GRAPHIC REPRESENTATION
AUDITORIUM
VISITOR
CENTER
ADMIN
WING
COMFORT
STATION
ENERGY CODE SUMMARY
APPLICABLE CODES
COMPLIANCE PATH
OPAQUE DOORS
CLIMATE ZONE
2024 INTERNATIONAL ENERGY CONSERVATION CODE
2024 INTERNATIONAL EXISTING BUILDING CODE
2024 INTERNATIONAL BUILDING CODE
PRESCRIPTIVE PATH: R-VALUE METHOD
AREAS OF ENERGY CONSERVATION IMPROVEMENT INCLUDE:
<N> WINDOWS AT ADMIN WING
<N> EXTERIOR DOORS
<E> EXTERIOR WALLS AT ADMIN WING
<N> ROOF AT COMFORT STATION
<N> SLAB-ON-GRADE AT COMFORT STATION
TABLE C402.1.3 OPAQUE THERMAL ENVELOPE MINIMUM R-VALUE (REFER TO ASSEMBLIES FOR CONFIGURATIONS)
ASSEMBLY LOCATION
<N> ROOF - ENTIRELY ABOVE DECK
<E> ROOF - ATTIC AND OTHER
WALLS - WOOD FRAMED - CAVITY
SLAB-ON-GRADE
REQUIRED PROVIDED INSULATION TYPE
NH POLYISO + COVERBOARD
MINERAL WOOL BATT
MINERAL WOOL BOARD
MINERAL WOOL BOARD
R-35 ci R-60 R-27
R-20 (FOR 24"
BELOW)
R-36.7 R-63* R-24** R-20
MAX U-FACTOR PROVIDED
U-0.37 ALL NEW EXTERIOR DOORS TO COMPLY
EXISTING DOORS TO REMAIN MAY NOT COMPLY
REFER TO SPECIFICATIONS
SWINGING DOORS
TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR & SHGC REQUIREMENTS
MAX U-FACTOR PROVIDED
U-0.28 U-0.36 U-0.63
REFER TO SPECIFICATIONSFIXED FENESTRATION
OPERABLE FENESTRATION
DOOR ENTRANCES
FENESTRATION MAXIMUM SOLAR HEAT GAIN COEFFICIENT (SHGC)
FIXED OPERABLE
U-0.40 U-0.48 U-0.64
PF < 0.2
0.2 < PF < 0.5
PF > 0.5
PROVIDED
REFER TO SPECIFICATIONSU-0.36
U-0.43 U-0.58
PF (PROJECTION FACTOR) = A/B
A = DISTANCE MEASURED HORIZONTALLY FROM GLAZING TO EDGE OF OVERHANG
B = DISTANCE MEASURED VERTICALLY FROM BOTTOM OF GLAZING TO UNDERSIDE OF OVERHANG
ALTERATIONS TO EXISTING BUILDINGS
7 PER IECC §C301.1 ROCKY MOUNTAIN NATIONAL PARK, GRAND COUNTY, COLORADO. USGS ELEV: 8,726.5'
§C503.1
NOTE: ELEMENTS OF THE BUILDING SHALL BE CONSIDERED EXEMPT FROM IECC COMPLIANCE DUE TO THE
BUILDING'S HISTORIC STATUS. SEE §C501.5 BELOW IN THIS CODE SUMMARY.
* INSULATION COMPLYING WITH SECTIONS C402.1 AND C402.2.1 SHALL BE PROVIDED FOR CEILING ALTERATIONS IN ADMIN WING, VISITOR CENTER, AND AUDITORIUM ADDITION. ROOF INSULATION REQUIREMENT AT EXISTING ROOFS WILL BE MET USING <E> R-25 CI ABOVE DECK (TO REMAIN) WITH NEW R-38 MINERAL WOOL BATT INSULATION INSTALLED IN THE ATTIC AT THE UNDERSIDE OF THE ROOF DECK, FOR A COMBINED TOTAL OF R-63.
** PER C503.2 THE EXISTING R-VALUE OF INSULATION SHALL NOT BE REDUCED AS PART OF ALTERATIONS TO EXISTING BUILDING THERMAL ENVELOPE ASSEMBLIES. <E> WALL ASSEMBLY HAD BATT INSULATION OF R-13.
ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING IS NOT LESS CONFORMING TO CODE THAN THE EXISTING BUILDING WAS PRIOR TO THE ALTERATION. ALTERATIONS SHALL NOT CREATE AN UNSAFE OR
HAZARDOUS CONDITION OR OVERLOAD EXISTING BUILDING SYSTEMS.
AIR BARRIER§C503.2.7
ALTERED BUILDING THERMAL ENVELOPE ASSEMBLIES SHALL BE PROVIDED WITH AN AIR BARRIER IN ACCORDANCE WITH §C402.6.1. THE AIR BARRIER IS NOT REQUIRED TO BE CONTINUOUS WITH UNALTERED PORTIONS OF THE BUILDING THERMAL ENVELOPE. TESTING REQUIREMENTS OF §C402.6.1 SHALL NOT BE REQUIRED.
VISITOR CENTER COMFORT STATION
THERMAL ENVELOPE*
C1 C2
R1
2.1 2.1
ADMIN WING
*THERMAL ENVELOPE
CONSISTS OF <N> AND
<E> ASSEMBLIES
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SCALE: A
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:0
3 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
G005
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 6 177
ENERGY CODE
ANALYSIS &
ASSEMBLIES
SCALEG005
SECTION - THERMAL ENVELOPE1
A
100 2010
SCALE OF FEET
GENERAL NOTES
1.
2.
3.
4.
CEILING TYPES SHOWN FOR GRAPHIC REFERENCE. ALL CEILING ELEMENTS TO BE INSTALLED PER
MANUFACTURER’S SPECIFICATIONS.
AT PARTITIONS W/ ACOUSTIC INSULATION, PROVIDE ¼” JOINTS AT PERIMETER AND PENETRATIONS AND
SEAL AIRTIGHT WITH BACKER ROD AND ACOUSTICAL SEALANT.
THE CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING, BACKING OR STRUCTURAL SUPPORT AS
REQUIRED TO PROPERLY INSTALLATION OF ALL MOUNTED ASSEMBLIES, INCLUDING ALL ATTACHED
EQUIPMENT, PLUMBING FIXTURES, MILLWORK, AND CASEWORK.
ALL STUDS SHALL BE FULL HEIGHT TO UNDERSIDE OF STRUCTURE UNLESS INDICATED OTHERWISE BY
PARTITION TYPE.
9"
ALL GENDER
(PROVIDE FEMALE/MALE SIGNAGE AT COMFORT
STATION RESTROOMS)
CL CL
ABAAS SIGNAGE
WITH BRAILLE
6" W
" H
" A
FF
M
IN
" A
FF
M
AX
B.
O.
LO
W
ES
T
TA
CT
ILE
CH
AR
AC
TE
R
B.
O.
H
IG
HE
ST
T
AC
TI
LE
CH
AR
AC
TE
R
FRONT
VIEW
SIDE
VIEW
SURFACE MOUNT
HAND DRYER
HORIZONTAL BABY CHANGING
TABLE
ACCESSIBLE WALL MOUNTED GRAB BARS
12"42"
KEEP 1 1/2"
AREA BELOW
BAR CLEAR
12"24"
36"
54"
39"
FRONT
VIEW
SIDE
VIEW
3'- 8"
SIDE
VIEW
FRONT
VIEW
BO
TT
OM
O
F
RE
FL
EC
NG
SU
RF
AC
E
RI
M
OF
S
IN
K
ACCESSIBLE WALL
MOUNTED LAVATORY
PR
OV
ID
E
UN
DE
R
LA
VA
TO
RY
P
LU
MB
IN
G
PR
OT
EC
ON
FRONT
VIEW
SIDE
VIEW
SOAP DISPENSER
SIDE
VIEW
FRONT
VIEW
TOP OF SEAT
ABAAS AUTOMATIC
FLUSH VALVE ON
TRANSFER/OPEN SIDE
16"
ACCESSIBLE WATER CLOSET
ACCESSIBLE WALL
MOUNTED RECEPTACLE
" M
AX
"M
IN
FRONT
VIEW
SIDE
VIEW
SEMI-RECESSED
PAPER TOWEL DISP. &
WASTE RECEPTACLE
URINAL
OF
U
RI
NA
L
" T O
RI
M
13-1/2" MIN
4" MAX*
FRONT
VIEW
AUTOMATED DOOR
OPENER PUSH BUTTON
AT INTERIOR OF DOOR 101
AND IN VEST 100: CENTER
AND RECESS BUTTON ON
HORIZONTAL MULLION
EXTERIOR BUTTONS
LOCATED ON FREE-
STANDING POLE, RE: ELEC
AND CIVIL
FRONT
VIEW
SIDE
VIEW
RECESSED WASTE
RECEPTACLE
KEEP 1 1/2"
AREA BELOW
BAR CLEAR
6"
SIDE
VIEW
FRONT
VIEW
4"MAX*
TO
T
OP
O
F
GR
IP
PI
NG
S
UR
FA
CE
4" MAX
4" MAX
2 3/4"
KNEE AND TOE
CLEARANCE
8" MIN "
6" MAX
11" MIN
" M
IN
17" MIN*
KNEE
TOE
*IF >17"
ADDITIONAL
SPACE MUST
PROVIDE 27"
MIN KNEE
CLEARANCE
" M
AX
" M
IN
*IF LEADING
EDGE HIGHER
THAN 27"
5"
SIDE
VIEW
FRONT
VIEW
WALL MOUNTED DRINKING FOUNTAIN
WITH INTEGRAL BOTTLE FILLER
FRONT
VIEW
SIDE
VIEW
SINGLE ROLL TOILET
TISSUE DISPENSER
SIDE
VIEW
FULLY-RECESSED FIRE
EXTINGUISHER CABINET
*IF LEADING EDGE HIGHER THAN 27"
15"5" 15"
3'- 8"
PROTRUDING DISPENSER
BELOW GRAB BAR
23 7/8"MIN
39 1/2"MAX
TOILET TISSUE
DISPENSER
MOUNTING AREA
CL
1 1 /2"
2 3/4"
" 34
RI
M
OF
S
IN
K
FLUSH CONTROL ON
TRANSFER/OPEN SIDE
7"
SIDE
VIEW
SEMI-RECESSED FIRE
EXTINGUISHER CABINET
"3'-
8"
2" MAXRECESSED
HANDLE
RECESSED
HANDLE
CL
9"
FRONT
VIEW
SIDE
VIEW
DOUBLE LARGE ROLL TOILET
TISSUE DISPENSER
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM
PRIME:
OTAK, INC.
REDMOND, WA
SUBCONTRACTOR:
ANDERSON HALLAS
ARCHITECTS
GOLDEN, CO
1/2 0/2
6 1
0:1 9:0
4 A M
Au tod es k D oc s:/
/20
-2
N
PS
R
OM
O Ka wu ne ec he
V C
DD
-C
A wO tak /20
0 N
PS
R
OM
O
KA
W
UN
EE
CH
E
VI
SI
TO
R
CE
NT
ER
_B
IM
0.r vt
G501
CR / VC
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
165639
326235
VC / MS / DM
CR / EMH
01/16/2026 7 177
ACCESSIBLE
MOUNTING HEIGHTS
N.T.S.G501
TYPICAL ABAAS RESTROOM SIGNAGE2
N.T.S.
ACCESSIBLE MOUNTING HEIGHTS
GENERAL NOTES - MOUNTING HEIGHTS
GENERAL NOTES - SIGNAGE
1.
2.
3.
4.
5.
6.
ALL ACCESSIBLE FIXTURE AND ACCESSORIES SHALL BE MOUNTED PER ABAAS.
ALL LAVATORIES SHALL HAVE UNDERLAVATORY PROTECTION. PIPE PROTECTOR SHOULD BE HARD, DURABLE, AND REMOVABLE.
ALL FAUCETS SHALL BE ANSI CERTIFIED.
MOUNTING HEIGHTS ARE PROVIDED AS GUIDANCE. VERIFY MOUNTING HEIGHTS WITH
RECOMMENDATIONS FROM EACH PRODUCT MANUFACTURER'S INSTRUCTIONS AND ABAAS.
COORDINATE WATER CLOSET, FLUSH VALVE, AND GRAB BAR INSTALLATION TO ENSURE ADEQUATE
SPACE FOR OPERATION OF FLUSH VALVE BELOW GRAB BAR WHILE MAINTAINING ALL REQUIRED
ABAAS MOUNTING HEIGHTS.
FINISH CLEARANCES ARE DIMENSIONED ON THIS SHEET.
1.
2.
3.
4.
ALL SIGNAGE TO BE ABAAS COMPLIANT.
FINAL FONT, GRAPHICS, AND MOUNTING HEIGHT TO BE CONFIRMED WITH C.O. PRIOR TO ORDERING.
SIGNAGE PANELS TO BE SECURELY FASTENED TO SUBSTRATE WITH CONCEALED FASTENERS, UNO.
PROVIDE ALL GENDER RESTROOM ABAAS SIGNAGE AT RR 112 AND RR 113; PROVIDE FEMALE ABAAS SIGNAGE AT RR 150 AND MALE ABAAS RR SIGNAGE AT RR 151. PROVIDE ABAAS DOOR SIGNAGE AT ALL
INTERIOR DOORS.
G501
165639
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
LEGEND AND
ABBREVIATIONSGC001
FDC
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
ACCESSIBILITY PLANS KEY
MAP
G600
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
ACCESSIBILITY PLANS I
G601
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
ACCESSIBILITY PLANS II
G602
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
ACCESSIBILITY PLANS III
G603
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
EXISTING CONDITIONS KEY
MAPC000
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
EXISTING CONDITIONS
PLAN IC001
POINT NORTHING EASTING ELEVATION
CP #3 1339835.59 2907179.78 8711.38
CP #60 1340053.44 2906921.38 8713.66
CONTROL POINTS
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED
PROFESSIONA L ENGIN
EE
R
KE
V I
N F
RA NC IS DOOLEY JR.
EXISTING CONDITIONS
PLAN IIC002
POINT NORTHING EASTING ELEVATION
CP #20 1340124.36 2907178.52 8724.30
CP #56 1340118.52 2907014.98 8714.37
CP #1000 1340323.40 2907233.54 8734.67
CONTROL POINTS
EM / CS
ZS
EM / KK
01/16/2026
REHABILITATE KAWUNEECHE VISITOR CENTER
ROCKY MOUNTAIN NATIONAL PARK
326235
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
AE FIRM:
PRIME:
OTAK, INC.
REDMOND, WA
CO
LO
RADO LICENSED