Attachment K - 1684614dwg9of16.pdf

PDF 19 MB Posted

Attached to
P242 Combat Rescue Helicopter Simulator Facility Federal contract opportunity
Solicitation number
N6247023R0003
Issued by
Department of the Navy Naval Facilities Engineering Command

View the file

Other files for this federal contract opportunity

Other files attached to P242 Combat Rescue Helicopter Simulator Facility, newest first.
File Type Posted
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Attachment K - Civil Drawings - Addendum1_REVISED.pdf PDF
Attachment K - Architecture Drawings - Addendum1_REVISED.pdf PDF
Amendment 0003.pdf PDF
Attachment N -B7300.pdf PDF
Attachment M - Safety and Coordination Plan_ITALIAN.pdf PDF
Amendment 0002.pdf PDF
Attachment L - Safety and Coordination Plan_ENGLISH.pdf PDF
P242 Amendment 0001.pdf PDF
Attachment K - 1684614dwg12of16.pdf PDF
Attachment I - INSTALLATION ACCESS REQUEST.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
P242 Solicitation.pdf PDF
Attachment K - 1684614dwg8of16.pdf PDF
Attachment K - 1684614dwg14of16.pdf PDF
Attachment K - 1684614dwg11of16.pdf PDF
Attachment K - 1684614dwg1of16.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment E - Price Proposal Form.pdf PDF
Attachment C - Construction Experience Project Data Sheet (1).pdf PDF
Attachment K - 1684614dwg6of16.pdf PDF
Attachment K - 1684614dwg7of16.pdf PDF
Attachment K - 1684614dwg16of16.pdf PDF
Attachment K - 1684614dwg15of16.pdf PDF
Attachment K - 1684614dwg2of16.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Attachment K - 1684614dwg4of16.pdf PDF
Attachment J -Specifications.pdf PDF
Attachment K - 1684614dwg5of16.pdf PDF
Attachment K - 1684614dwg13of16.pdf PDF
Attachment K - 1684614dwg10of16.pdf PDF
Attachment K - 1684614dwg3of16.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - Informazione Antimafia.pdf PDF
Attachment G - Comunicazione Antimafia.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SYMBOLS / SIMBOLI

CALLOUT PLAN,

SECTION OR DETAIL /

PIANO RICHIAMO,

SEZIONE O DETTAGLIO

COLUMN GRID LABEL - NEW /

ETICHETTA GRIGLIA COLONNA -

NUOVA

CL

LEVEL LINE /

LINEA LIVELLO

ROOM TAG /

ETICHETTA SALA

KEYNOTE / NOTA PRINCIPALE

TOILET ROOM ACCESSORIES /

ACCESSORI SERVIZI IGIENICI

ELEVATION MARK /

SEGNO ALTEZZA

DOOR NUMBER TAG - SEE SCHEDULE /

ETICHETTA NUMERO PORTA - VEDI

PROGRAMMA

PARTITION TYPE /

TIP DI TRAMEZZATURA

#X#.#

ROOM NAME

BUILDING SECTION /

SEZIONE EDIFICIO

WALL SECTION /

SETTO MURARIO

INTERIOR SECTION /

SEZIONE INTERNA

DETAIL SECTION /

SEZIONE DETTAGLIO

INTERIOR EXTERIOR

ELEVATIONS /

ELEVAZIONI

VIEW TITLE

# SCALE:

VIEW CALLOUT /

VISUALIZZA RICHIAMO

NORTH ARROW / FRECCIA NORD

CENTER LINE / LINEA CENTRALE

FLOOR TRANSITION /

TRANSIZIONE PAVIMENTO

ROOF PERCENT SLOPE DOWN /

PENDENZA DEL TETTO IN

PERCENTUALE

SPOT ELEVATION /

ALTEZZA PUNTO

COLUMN GRID LABEL - EXISTING /

ETICHETTA GRIGLIA COLONNA -

ESISTENTE

REVISION / REVISIONE

EXISTING DOOR AND/OR FRAME TO

REMAIN - SEE DOOR SCHEDULE FOR ANY

ADDITIONAL WORK / PORTA E/O TELAIO

ESISTENTI DA MANTENERE - VEDI

PROGRAMMA PORTE PER INTERVENTI

SUPPLEMENTARI

REMOVE DOOR AND FRAME /

RIMUOVERE PORTA E TELAIO

NEW DOOR AND FRAME / PORTA E

TELAIO NUOVI

DOOR DESIGNATIONS / DESIGNAZIONI PORTE

PLAN

NORTH

TA##

ITEM OVERHEAD / COMPONENTE SOSPESO

DEMOLISHED ITEM / ELEMENTO DEMOLITO

MATERIAL GRAPHICS / GRAFICI MATERIALI

CAST-IN-PLACE-CONCRETE /

CALCESTRUZOO GETTATO IN OPERA

STUD WALLS / PARETI CON TRAVI

VERTICALI

STEEL / ACCAIO

EARTH / TERRA

GRAVEL/ENGINEERED FILL /

GHIAIA/RIEMPIMENTO

SVILUPPATO

PLASTER OR GYPSUM BOARD,

OR EXTERIOR SHEATHING /

PANNELI IN GESSO O MALTA O

RIVESTIMENTO ESTERNO

BATT INSULATION /

ISOLAMENTO LANA DI VETRO

RIGID INSULATION /

ISOLAMENTO RIGIDO

PLYWOOD / COMPENSATO

EXISTING WALLS / PARETI

ESISTENTI

1 HOUR / 1 ORA

2 HOUR / 2 ORE

PLANS/ PLAN FIRE RATED GRAPHICS /

GRAFICI RESISTENZA AL FUOCO

PLANIMETRIA/E

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A S

E

A V

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

R

IM

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:1

P M

S Y

M B

O L

S

A B

B R

E V

IA

T

IO

N

JEBZZZZ

A-001

S

IM

B O

L I

E A

B B

R E

V

IA

Z

IO

N I

14125456

KMC

ABB DESCRIPTION / DESCRIZIONE

PROP PROPERTY / PROPRIETA

PSI POUNDS PER SQUARE INCH / LIBBRE PER

POLLICE QUADRATO

PSIG POUNDS PER SQUARE INCH GAUGE /

INDICATORE LIBBRE PER POLLICE

QUADRATO

INDICATORE LIBBRE PER POLLICE

QUADRATO

PT POINT / PUNTO

PTD PAINTED / VERNICIATO

__________ Q __________

QTY QUANTITY / QUANTITÀ

__________ R __________

R RISER OR RADIUS / COLONNA O RAGGIO

RCP REFLECTED CEILING PLAN / PLANIMETRIA

SOFFITTO RIFLESSO

RD ROOF DRAIN / SCOLO DEL TETTO

REF REFER / REFERENCE / FARE

RIFERIMENTO/RIFERIMENTO

REG REGISTER / REGISTRO

REINF REINFORCING / RINFORZO

REQ'D REQUIRED / RICHIESTO

RFG REFRIGERATOR / FIGORIFERO

RG RANGE / INTERVALLO

RM ROOM / LOCALE/SALA

RO ROUGH OPENING / APERTURA NON RIFINITA

RTS RUBBER TRANSITION STRIP / STRISCIA DI

TRANSIZIONE IN GOMMA

RWC RAIN WATER CONDUCTOR / TUBATURA PER

ACQUA PIOVANA

__________ S __________

S SOUTH / SUD

SAN SANITARY / SANITARIO

SCHD SCHEDULE / PROGRAMMA

SEC SECTION / SEZIONE

SIM SIMILAR / SIMILE

SPKLR SPRINKLER / INPIANTO SPRINKLER

SQ SQUARE / QUADRO/ATO

SS STAINLESS STEEL / ACCIAIO INOX

STD STANDARD / STANDARD

STL STEEL / ACCIAIO

STOR STORAGE / VAN DI DEPOSITO

SUSP SUSPEND, SUSPENDED, OR SUSPENSION /

SOSPENDERE, SOSPESO O SOSPENSIONE

SYS SYSTEM / SISTEMA

__________ T __________

"T" TEE (BAR OR W) / T(BARRO O W)

T TREAD / SUPERFICIE

T/ TOP OF / PARTE SUPERIORE DI

T/C TOP OF CURB / PARTE SUPERIORE DEL

CORDOLO

TB TACKBOARD / BACHECA

TC TERRA COTTA / TERRACOTTA

TEL TELEPHONE / TELEFONO

TEMP TEMPERED OR TEMPERATURE / TEMPRATO O

TEMPERATURA

TERM TERMINATE / TERMINAL /

TERMINARE/TERMINALE

THRESH THRESHOLD / SOGLIA

TLT TOILET / TOILETTE

TV TELEVISION / TELEVISIONE

TYP TYPICAL / TIPICO

__________ U __________

UH UNIT HEATER / AEROTERMO

UL UNDERWRITER'S LABORATORY /

LABORATORIO SOTTOSCRITTORE

UMCT UNGLAZED MOSAIC CERAMIC TILE /

PIASTRELLA IN CERAMICA OPACA A MOSAICO

UNO UNLESS NOTED OTHERWISE / SE NON

DIVERSAMENTE INDICATO

__________ V __________

VEST VESTIBULE / VESTIBOLO

VIF VERIFY IN FIELD / VERIFICARE SUL CAMPO

__________ W __________

W WEST / OVEST

W/ WITH / CON

W/O WITHOUT / SENZA

WC WATER CLOSET / WC

WIN WINDOW / FINESTRA

WP WATERPROOF(ING) /

INPERMEABILE/IMPERMEABILIZZAZIONE

WSCT WAINSCOT / RIVESTIMENTO IN LEGNO

WT WEIGHT / PESO

WWF WELDED WIRE REINFORCEMENT / RINFORZO

ELETTROSALDATO

ABB DESCRIPTION / DESCRIZIONE

FHC FIRE HOSE CABINET / ARMADIETTO

MANICHETTA

FL FLOOR / PAVIAMENTO

FL CO FLOOR CLEANOUT / SGOMBRO PAVIAMENTO

FP FIRE PROTECTION / PROTEZIONE

ANTINCENDIO

FPRF FIREPROOF(ING) / IGNIFUGO/RESISTENTE AL

FUOCO

FR FIRE RATED OR FRAME / RESISTENTE AL

FUOCO O TELAIO

FT FOOT/FEET / PIEDE/I

__________ G __________

GA GAUGE / DIMA/INDICATORE

GL GLASS OR GLAZING / VETRO O VETRATA

GRD GROUND / TERRA

GWB GYPSUM WALL BOARD / CARTONGESSO PER

PARETE

__________ H __________

HB HOSE BIBB / RUBINETTO PER FLESSIBILE

HC HANDICAP(PED) / (PORTATORE DI) HANDICAP

HDW HARDWARE / MINUTERIA FERRAMENTA

HM HOLLOW METAL / METALLO CAVO

HOR HORIZONTAL / ORRIZZONTALE

HP HIGH POINT / PUNTO ALTO

HTR HEATER / IMPIANTO RISCALDAMENTO

__________ I __________

ID INSIDE DIAMETER / DIAMETRO INTERNO

INT INTERIOR / INERNO

__________ J __________

JB JAMB / STIPITE

JST JOIST / TRAVETTO

JT JOINT / GIUNZIONE/RACCORDO

__________ L __________

LAM LAMINATE / LAMINATO

LAN LOCAL AREA NETWORK CONNECTION /

COLLEGAMENTO ALLA RETE LOCALE

LAV LAVATORY / TOILETTE

LB POUND / LIBBRA

LF LINEAL FOOT / PIEDE LINEARE

LP LOW POINT / PUNTO BASSO

LTL LINTEL /ARCHITRAVE

__________ M __________ m METERS / METRI

MAS MASONRY / MURATURA

MAX MAXIMUM / MASSIMO

MDF MEDIUM DENSITY FIBERBOARD / PANNELLO

IGNIFUGO DENSITÀ MEDIA

MECH MECHANICAL / MECCANICO

MEZZ MEZZANINE / MEZZANINO

MFR MANUFACTURE / PRODUZIONE

MH MANHOLE / POZZETTO

MICRO MICROWAVE / MICROONDE

MIN MINIMUM / MINIMO

MISC MISCELLANEOUS / VARIE

mm MILLIMETERS / MILLIMETRI

MO MASONRY OPENING / APERTURA NELLA

MURATURA

MTD MOUNTED / MONTATO

MTL METAL / METALLO

__________ N __________

N NORTH / NORD

NFPA NATIONAL FIRE PROTECTION ASSOCIATION /

ASSOCIAZIONE NAZIONALE PROTEZIONE

ANTINCENDIO

NIC NOT IN CONTRACT / ESCLUSO DALL'APPALTO

NOM NOMINAL / NOMINALE

NTS NOT TO SCALE / NON IN SCALA

__________ O __________

OC ON CENTER / SU CENTRO

OD OUTSIDE DIAMETER / DIAMETRO ESTERNO

OFF OFFICE / UFFICIO

OPNG OPENING / APERTURA

OPP OPPOSITE / OPPOSTO/DI FRONTE

__________ P __________

PART PARTITION / TRAMEZZO/TRAMEZZATURA

PL PLATE / PIASTRA

PLAM PLASTIC LAMINATE / LAMINATO IN PLASTICA

PLAS PLASTER / GESSO

PLYWD PLYWOOD / COMPENSATO

PNL PANEL / PANNELLO

POS POINT OF SALE / PUNTO DI VENDITA

PR PAIR / PAIO/COPPIA

PRCST PRECAST / PREFABBRICATO

PREFAB PREFABRICATED / PREFABBRICATO

ABB DESCRIPTION / DESCRIZIONE

__________ A __________

& AND / E

< ANGLE / ANGOLO

@ AT / A

ACP ACOUSTIC CEILING PANEL / PANNELLO PER

CONTROSOFFITTO ACUSTICO

ADJ ADJACENT, ADJUSTABLE / ADIACENTE,

REGOLABILE

AED AUTOMATED EXTERNAL DEFIBRILLATOR /

DEFIBRILLATORE ESTERNO AUTOMATICO

AFF ABOVE FINISHED FLOOR / SOPRA AL

PAVIMENTO FINITO

AP ACCESS PANEL / PANNELLO DI ACCESSO

APPROX APPROXIMATE(LY) / APPROSSIMATIVAMENTE

ARCH ARCHITECT OR ARCHITECTURAL /

ARCHITETTO O ARCHITETTONICO

ASTM AMERICAN SOCIETY FOR TESTING MATERIAL

/ SOCIETÀ AMERICANA PER IL COLLAUDO DI

MATERIALI

ATTEN ATTENUATE, ATTENUATION

AVG AVERAGE / MEDIA

__________ B __________

B/ BOTTOM OF / FONDO DI

B/C BOTTOM OF CURB / FONDO DEL

BC BASE CABINET / CORDOLO

BD BOARD / PANNELLO

BIT BITUMINOUS / BITUMINOSO

BLDG BUILDING / EDIFICIO

BSMT BASEMENT / BASAMENTO

__________ C __________

[ CHANNEL / CANALE

CAB CABINET / ARMADIETTO

CC CENTER TO CENTER / DA CENTRO A CENTRO

CG CORNER GUARD / PARASPIGOLI

CJ CORNER JOINT / GIUNTO D'ANGOLO

CL CENTER LINE / LINEA CENTRALE

CLG CEILING / SOFFITTO

CLG HT CEILING HEIGHT / ALTEZZA DEL SOFFITTO

CLO CLOSET / RIPOSTIGLIO

CLR CLEAR / LIBERO

CMU CONCRETE MASONRY UNIT / UNITÀ

MURATURA CALCESTRUZZO

CO CLEAN OUT / SVOUTAMENTO

COL COLUMN / COLONNA

CONC CONCRETE / CASCESTRUZZO

CONT CONTINUOUS / CONTINUO

CORR CORRIDOR / CORRIDOIO

CP COPIER / COPIATRICE

CT CERAMIC TILE / PIASTRELLA IN CERAMICA

CY CUBIC YARD / IARDA CUBICA

__________ D __________

DF DRINKING FOUNTAIN / FONTANELLE ACQUA

DIA DIAMETER / POTABILE

DIM DIMENSION / DIMENSIONE

DN DOWN / VERSO IL BASSO

DW DISHWASHER / LAVASTOVIGLIE

DWG DRAWING / DISEGNO

__________ E __________

E EAST / EST

EA EACH / CIASCUNO/A

EB EDGE BANDING / BORDATURA

EIFS EXTERIOR INSULATION FINISH SYSTEM /

SISTEMA DI FINITURA PER ISOLAMENTO

ESTERNO

EJ EXPANSION JOINT / GIUNTO DI DILATAZIONE

ELEC ELECTRICAL / ELETTRICO

ELEV ELEVATOR / ASCENSORE

EMER EMERGENCY / EMERGENZA

ENCL ENCLOSE(URE) / RECINTARE/RECINZIONE

EP ELECTRICAL PANEL / PANNELLO ELETTRICO

EQ EQUAL / UGUALE

EQUIP EQUIPMENT / ATTREZZATURA

EWC ELECTRIC WATER COOLER /

RAFFREDDAMENTO ACQUA ELETTRICO

EXIST EXISTING / PREESISTENTE

EXP BLT EXPANSION BOLT / BULLONE A ESPANSIONE

EXT EXTERIOR / ESTERNO

__________ F __________

< FABRIC / TESSUTO

F/F FACE TO FACE / DI FRONTE

FAX FAX / FACSIMILE

FE FIRE EXTINGUISHER / ETINTORE

FEC FIRE EXTINGUISHER CABINET / ARMADIETTO

PER ESTINITORE

Approved by CDR Jonathan Horner, ROICC, via SAT-TO form

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:1

P M

G E

N E

R A

L N

O T

E

A-002

N O

T E

G E

N E

R A

L I

14125457

KMC

NOTE - GENERALE

22 PROTECT MONUMENTS, IRON PINS, AND PROPERTY CORNERS DURING CONSTRUCTION / DURANTE LA

COSTRUZIONE, PROTEGGERE GLI ANGOLI DELLA PROPRIETÀ, BARRE DI FERRO O MONUMENTI

23 PROVIDE ADDITIONAL FURRING (THE ENTIRE LENGTH OF THE WALL) TO FULLY CONCEAL MECHANICAL, ELECTRICAL, PLUMBING AND STRUCTURAL ITEMS THAT PROJECT FROM THE FACE OF THE WALL OR PARTITION AND ARE NOT SPECIFICALLY NOTED TO BE SURFACE MOUNTED / AGGIUNGERE RIVESTIMENTO (PER L'INTERA LUNGHEZZA DELLA PARETE) IN MODO DA NASCONDERE COMPLETAMENTE GLI ELEMENTI STRUTTURALI, MECCANICI, ELETTRICI, IDRAULICI CHE SPORGONO DALLA FACCIATA O DAI TRAMEZZI E CHE

NON SONO SPECIFICATAMENTE MONTATI A PARETE

24 REFER TO ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS, BUILDING UTILITY ENTRANCE LOCATIONS AND EXACT LOCATIONS AND DIMENSIONS OF EXITS, CANOPIES, RAMPS, DOWNSPOUTS, GRAVEL AREAS ADJACENT TO BUILDING WALLS, UTILITY ENTRANCE LOCATIONS AND BOLLARDS IN BUILDING WALKWAYS / FARE RIFERIMENTO ALLE PLANIMETRIE ARCHITETTONICHE PER LE QUOTE COSTRUTTIVE, LE UBICAZIONI DEGLI INGRESSI DEGLI IMPIANTI DI SERVIZIO E LE POSIZIONI E DIMENSIONI ESATTE DI USCITE, TETTOIE, RAMPE, GRONDAIE, ZONE CON GHIAIA ADIACENTI ALLE PARETI DELL'EDIFICIO, LE POSIZIONI DI INGRESSO

DEGLI IMPIANTI DI SERVIZIO E LE COLONNE DEI PASSAGGI PEDONALI DELL'EDIFICIO

25 VISIT THE SITE AND VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING CONSTRUCTION - DISCREPANCIES MUST BE NOTED AND SENT TO THE ARCHITECT WITH ADEQUATE TIME TO REVIEW PRIOR TO STARTING THAT PORTION OF THE WORK IN ORDER TO AVOID PROJECT DELAYS / VISITARE IL SITO E VERIFICARE LE CONDIZIONI PRIMA DI AVVIARE LA COSTRUZIONE - EVENTUALI DISCREPANZE DEVONO ESSERE ANNOTATE E INVIATE ALL'ARCHITETTO CON TEMPISTICHE ADEGUATE PER EFFETTUARE UNA REVISIONE PRIMA DI AVVIARE LA SPECIFICA PORZIONE DEL LAVORO, COSÌ DA EVITARE RITARDI NEL

PROGETTO

26 CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH LOCAL JURISDICTION AND NFPA 10. MAXIMUM TRAVEL DISTANCE TO NEAREST FIRE EXTINGUISHER FROM ANY POINT IN THE BUILDING MUST NOT EXCEED 22.8M. EXISTING FIRE EXTINGUISHERS SHALL BE TESTED AND RE-USED IF FULLY OPERATIONAL. FIRE EXTINGUISHERS MUST BE SIZED FOR NO LESS THAN ORDINARY HAZARD / L'APPALTATORE DEVE FORNIRE ESTINTORI PORTATILI COME PREVISTO DALLE AUTORITÀ LOCALI E DALLA NFPA 10. LA DISTANZA MASSIMA DALL'ESTINTORE PIÙ VICINO IN QUALSIASI PUNTO DELL'EDIFICIO NON DEVE SUPERARE I 22,8M. GLI ESTINTORI ESISTENTI DEVONO ESSERE COLLAUDATI E RIUTILIZZATI SE TOTALMENTE OPERATIVI. GLI ESTINTORI DEVONO ESSERE DIMENSIONATI IN MODO DA ESSERE ADEGUATI A UN LIVELLO DI

PERICOLO ALMENO “ORDINARIO”

27 CONTRACTOR AND SUBCONTRACTOR MUST BE LICENSED TO PERFORM THEIR REQUESTED DUTIES AS REQUIRED IN ACCORDANCE WITH LOCAL STANDARDS / L'APPALTATORE E IL SUBAPPALTATORE DEVONO DISPORRE DELLA LICENZA PER ESEGUIRE I LAVORI PREVISTI, COME RICHIESTO DALLE NORMATIVE LOCALI

28 COMPARE STRUCTURAL SECTIONS WITH ARCHITECTURAL SECTIONS AND REPORT ANY DISCREPANCY TO THE ARCHITECT PRIOR TO FABRICATION OR INSTALLATION OF STRUCTURAL MEMBERS / CONFRONTARE LE

SEZIONI STRUTTURALI CON QUELLE ARCHITETTONICHE E SEGNALARE EVENTUALI DISCREPANZE

ALL'ARCHITETTO PRIMA DELLA COSTRUZIONE O INSTALLAZIONE DEI COMPONENTI STRUTTURALI

NOTE - GENERALE

1 DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED OTHERWISE / LE DIMENSIONI SONO ESPRESSE IN

MILLIMETRI (mm) SE NON DIVERSAMENTE INDICATO 2 THESE GENERAL NOTES ARE NOT INTENDED TO REPLACE SPECIFICATIONS - REFER TO SPECIFICATIONS

FOR REQUIREMENTS IN ADDITION TO GENERAL NOTES / IQUESTE NOTE GENERALI NON SOSTITUISCONO LE SPECIFICHE - FARE RIFERIMENTO ALLE SPECIFICHE PER I REQUISITI AGGIUNTIVI ALLE NOTE GENERALI

3 THE TERMS RENOVATE AND REHABILITATE ARE USED INTERCHANGEABLY IN THESE DOCUMENTS / ALL'INTERNO DI QUESTI DOCUMENTI, I TERMINI RINNOVARE E RIQUALIFICARE VENGONO USATI IN MODO

INTERSCAMBIABILE

4 ROOM AREAS AND PERIMETERS ARE APPROXIMATE AND FOR REFERENCE ONLY. VERIFY QUANTITIES AND DIMENSIONS IN FIELD / LE AREE E I PERIMETRI DEI LOCALI SONO APPROSSIMATIVI ED ESPRESSI PER MERO

RIFERIMENTO. VERIFICARE LE QUANTITÀ E LE MISURE SUL CAMPO

5 NO DEVIATIONS FROM THESE CONTRACT DOCUMENTS MUST BE MADE WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ARCHITECT / NON POSSONO ESSERE EFFETTUATI SCOSTAMENTI DAI PRESENTI

DOCUMENTI CONTRATTUALI SENZA AVER OTTENUTO APPROVAZIONE SCRITTA DALL'ARCHITETTO

6 DO NOT SCALE DIMENSIONS FROM DRAWINGS - REQUEST NECESSARY DIMENSIONS NOT SHOWN ON THE DRAWINGS FROM THE ARCHITECT / NON CALCOLARE LE QUOTE DAI DISEGNI - RICHIEDERE ALL'ARCHITETTO

LE QUOTE NECESSARIE E NON ESPRESSE SUI DISEGNI

7 DIMENSIONS ARE TO FINISH FACE OF PARTITION OR CENTER OF DOORS, WINDOWS AND OPENINGS UNLESS NOTED OTHERWISE - NON-DIMENSIONED DOOR LOCATIONS MUST BE OFFSET 100mm FROM THE ADJACENT WALL TO THE HINGE SIDE OF THE DOOR OPENING / SE NON DIVERSAMENTE INDICATO, LE QUOTE SI RIFERISCONO ALLA SUPERFICIE FINITA DI TRAMEZZI O CENTRO DELLE PORTE, FINESTRE E APERTURE - LE UBICAZIONI DELLE PORTE NON QUOTATE DEVONO ESSERE COMPENSATE DI 100mm DAL MURO ADIACENTE

AL LATO DELL'APERTURA IN CUI SONO PREVISTI I CARDINI

8 DETAILS SHOWN ON DRAWINGS ARE TYPICAL FOR ALL SIMILAR CONDITIONS / I DETTAGLI DEI DISEGNI SONO

STANDARD PER TUTTE LE CONDIZIONI SIMILI

9 DRAWING NOTES AND SPECIFICATIONS ARE INSTRUCTIONS TO THE CONTRACTOR AND APPLY TO THE WORK IN SCOPE UNLESS MORE SPECIFIC INFORMATION IS SHOWN ELSEWHERE ON THE DRAWINGS OR WRITTEN IN THE SPECIFICATIONS - IN THE EVENT OF CONFLICTING INSTRUCTIONS, THE ARCHITECT MUST DETERMINE WHAT CONTROLS / LE NOTE E LE SPECIFICHE DEI DISEGNI SONO ISTRUZIONI PER L'APPALTATORE E SI APPLICANO AL LAVORO SE NON SONO PRESENTI INFORMAZIONI PIÙ DETTAGLIATE ALL'INTERNO DEL DISEGNO O NELLE SPECIFICHE - IN CASO DI DISCREPANZE TRA LE ISTRUZIONI, L'ARCHITETTO DEFINIRÀ

QUALE DEBBA PREVALERE

10 VERIFY DIMENSIONS IN THE FIELD AND COORDINATE DIMENSIONS SHOWN ON THE CONTRACT DRAWINGS WITH FABRICATION AND FIELD CONDITIONS AND REPORT INCONSISTENCIES TO THE ARCHITECT BEFORE PROCEEDING WITH WORK / VERIFICARE LE QUOTE SUL CAMPO E COORDINARE LE MISURE INDICATE SUI DISEGNI CONTRATTUALI CON LE CONDIZIONI EFFETTIVE DI COSTRUZIONE E SEGNALARE EVENTUALI

INCOERENZE ALL'ARCHITETTO PRIMA DI PROCEDERE CON IL LAVORO

11 PRINCIPAL OPENINGS IN THE STRUCTURE ARE SHOWN ON THESE DRAWINGS - THE GENERAL CONTRACTOR MUST EXAMINE THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR REQUIRED

OPENINGS GENERAL CONTRACTOR MUST VERIFY SIZE AND LOCATION OF OPENINGS WITH

SUB-CONTRACTORS PRIOR TO CONSTRUCTION / LE APERTURE PRINCIPALI NELLA STRUTTURA SONO INDICATE NEI DISEGNI - L'APPALTATORE GENERALE DEVE VERIFICARE LE APERTURE RICHIESTE SUI DISEGNI DELLE PARTI ARCHITETTONICHE, MECCANICHE, ELETTRICHE E IDRAULICHE; PRIMA DELL'EDIFICAZIONE, L'APPALTATORE GENERALE DEVE VERIFICARE LA DIMENSIONE E LA POSIZIONE DELLE APERTURE INSIEME AI

SUBAPPALTATORI

12 STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, AND, EXCEPT WHERE SPECIFICALLY SHOWN, DO NOT INDICATE THE METHOD OR MEANS OF CONSTRUCTION - SUPERVISE CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, SEQUENCE, AND APPLICABLE SAFETY REGULATIONS TO BE FOLLOWED / LE SPECIFICHE E I DISEGNI STRUTTURALI RAPPRESENTANO LA STRUTTURA FINITA E, SE NON INDICATO IN MODO SPECIFICO, NON RIPORTANO IL METODO E I MEZZI COSTRUTTIVI - MONITORARE MEZZI, METODI, PROCEDURE, TECNICHE, SEQUENZA E REGOLE DI SICUREZZA

APPLICABILI ALLA COSTRUZIONE

13 BE RESPONSIBLE FOR SCHEDULING AND COORDINATING THE WORK OF THE SUB-CONTRACTORS - BE RESPONSIBLE TO COORDINATE WITH THE BUILDING OWNER, TENANT OR HIS REPRESENTATIVES THE DELIVERY AND INSTALLATION OF ITEMS BEING PROVIDED AND INSTALLED BY OTHERS / RITENERSI RESPONSABILI DELLA PROGRAMMAZIONE E DEL COORDINAMENTO DEL LAVORO DEI SUBAPPALTATORI - RISPONDERE DEL COORDINAMENTO CON IL PROPRIETARIO DELL'EDIFICIO, IL LOCATARIO O SUO RAPPRESENTANTE PER LA CONSEGNA E L'INSTALLAZIONE DEI COMPONENTI FORNITI E INSTALLATI DA TERZI

14 MECHANICAL, PLUMBING AND ELECTRICAL WORK RELATED TO DEMOLITION AND NEW INSTALLATION OF COMPONENTS MUST COMPLY WITH ALL APPLICABLE CODES / GLI INTERVENTI SULLE PARTI MECCANICHE, IDRAULICHE ED ELETTRICHE RELATIVI ALLA DEMOLIZIONE E NUOVA INSTALLAZIONE DI COMPONENTI DEVE

RISPETTARE TUTTE LE NORMATIVE APPLICABILI

15 MATERIALS, FABRICATION AND INSTALLATION MUST COMPLY WITH THE APPLICABLE REQUIREMENTS AND SPECIFICATIONS FOR EACH DIVISION OF WORK / I MATERIALI, LA COSTRUZIONE E L'INSTALLAZIONE DEVONO

RISPETTARE I REQUISITI E LE SPECIFICHE APPLICABILI PER OGNI PARTE DEL LAVORO

16 COMPLY WITH APPLICABLE CODES AND ORDINANCES, LAWS AND SAFETY ORDERS AS DIRECTED BY LOCAL JURISDICTION / RISPETTARE ORDINANZE, NORMATIVE, LEGGI E ORDINI DI SICUREZZA APPLICABILI ED

EMANATI DALLA GIURISDIZIONE LOCALE

17 BE RESPONSIBLE FOR THE TIMELY ORDERING OF MATERIALS INCLUDED IN THESE CONTRACT DOCUMENTS - SOME ITEMS IN THESE DOCUMENTS MAY REQUIRE LONG LEAD TIMES OR SPECIAL COORDINATION.

SUBSTITUTIONS WILL NOT BE ALLOWED FOR MATERIAL NOT ORDERED IN A TIMELY FASHION / RITENERSI RESPONSABILI PER L'ORDINAZIONE TEMPESTIVA DEI MATERIALI RIPORTATI NEI DOCUMENTI CONTRATTUALI - PER ALCUNI ARTICOLI DI QUESTI DOCUMENTI POTREBBERO ESSERE NECESSARIE TEMPISTICHE LUNGHE O UN PARTICOLARE COORDINAMENTO. LE SOSTITUZIONI NON SONO PERMESSE PER I MATERIALI NON

ORDINATI TEMPESTIVAMENTE

18 CHECK AND VERIFY DIMENSIONS AND GRADE CONDITIONS, (BOTH NEW AND EXISTING) REPORTING DISCREPANCIES TO THE ARCHITECT PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH EACH PHASE OF THE WORK / VERIFICARE LE DIMENSIONI E LE CONDIZIONI (PER NUOVO ED ESISTENTE), SEGNALANDO LE DISCREPANZE ALL'ARCHITETTO, PRIMA DI ORDINARE MATERIALI O PROCEDERE NELLE FASI DEL LAVORO

19 CHECK AND VERIFY DIMENSIONS PRIOR TO COMMENCING CONSTRUCTION - DISCREPANCIES MUST BE NOTED AND SENT TO THE ARCHITECT WITH ADEQUATE TIME TO REVIEW PRIOR TO STARTING THAT PORTION OF THE WORK IN ORDER TO AVOID PROJECT DELAYS / VERIFICARE LE DIMENSIONI PRIMA DI AVVIARE LA COSTRUZIONE - EVENTUALI DISCREPANZE DEVONO ESSERE ANNOTATE E INVIATE ALL'ARCHITETTO CON TEMPISTICHE ADEGUATE PER EFFETTUARE UNA REVISIONE PRIMA DI AVVIARE LA SPECIFICA PORZIONE DEL

LAVORO, COSÌ DA EVITARE RITARDI NEL PROGETTO

20 CLEAN, PATCH AND REPAIR SURFACES DAMAGED BY DEMOLITION, ALTERATION OR INSTALLATION OF THE WORK / PULIRE E RIPARARE LE SUPERFICI DANNEGGIATE DALLA DEMOLIZIONE, L'ALTERAZIONE O

L'INSTALLAZIONE DURANTE IL LAVORO

21 PREPARE WALLS AND PARTITIONS AS REQUIRED BY THE FINISH MANUFACTURER TO RECEIVE THE FINISHES SPECIFIED / PREPARARE LE PARETI E I TRAMEZZI COME RICHIESTO DAL PRODUTTORE DELLE FINITURE

SPECIFICATE

REAR WALL ELEV / ALTEZZA PARETE POST

TOILET PAPER

DISPENSER /

DISPENSER CARTA

IGIENICA

M

IN

WATER CLOSET IS FOR REF.

SEE P-SERIES FOR TYPE /

WC PER RIFERIMENTO.

VEDERE SERIE P PER LA

TIPOLOGIA

SEAT COVER

DISPENSER /

DISPENSER

COPRISEDUTA

FLUSH CONTROL

ON OPEN SIDE OF WC /

COMANDO SCIACQUONE SUL

LATO APERTO DEL WC

M

AX

SIDE WALL ELEV / ALTEZZA PARETE LAT

MIN CLEAR / MIN LIBERI

1525 CLEAR / 1525 LIBERI

1420 MIN CLEAR / 1420 MIN LIBERI

TO

O

PE

R

AB

LE

P

AR

TS

AL

LE

C O

M

PO

N

EN

TI

IN

U

SO

M

IN

TOILET ROOM / LOCALE WC

ISOLARE O NASCONDERE

TUTTI I TUBI DELL'ACQUA

E DI SCARICO

SOAP DISPENSER /

DISPENSER

SAPONE

MIRROR / SPECCHIO

PAPER

TOWEL

DISPENSER /

DISPENSER

DISPENSER

SALVIETTE

CARTA

ROBE HOOK / GANCIO

TOWEL RING/BAR /

ANELLO/BARRA

PER ASCIUGAMANI

S

TA

N D

AR

D

S

TA

N D

AR

D

S

TA

N D

AR

D

S

TA

N D

AR

D

FAUCET AND SOAP DISPENSER CONTROLS

SHALL HAVE A REACH DEPTH OF 280mm

MAX /

I COMANDI DEL RUBINETTO E DEL

DISPENSER SAPONE DEVONO AVERE UNA

PROFONDITÀ RAGGIUNGIBILE DI 280mm

MAX

M

AX

M

IN

T/ O

O

PE

R

AB

LE

P

AR

TS

AL

LE

C

O M

PO

N

EN

TI

IN

U

SO

M

AX

SINKS w/o CASEWORK /

LAVABI SENZA MOBILE

205 MIN

430 MIN

COAT HOOK & SHELF /

APPENDIABITI E

RIPIANO

M

IN

PAPER TOWEL

DISPENSER & WASTE

RECEPTICAL /

DISPENSER

SALVIETTE CARTA E

RACCOLTA RIFIUTI

TO

A

N Y

C O

N

TR

O

LS

A N

D

O

PE

R

AT

IN

G

M

EC

H

AN

IS

M

AD

O G

N I C

O M

AN

D

M

EC

C

AN

IS

M O

D I

FU

N

ZI

O

N

AM

EN

TO

SIDE VIEW /

VISTA LATERALE

FRONT VIEW /

VISTA FRONTALE

FACE OF WALL / SUPERFICIE

DELLA PARETE

100 MAX MANIGLIA COMPRESA

100 MAX INCLUDING HANDLE /

CLR FLOOR SPACE

750 MIN

CLR FLOOR SPACE

1220 MIN

TO

B

O

TT

O M

M

AX

M

AX

A

LT

EZ

ZA

R

AG

G

IU

N G

IB

IL

E

M

AX

R

EA

C

H H

EI

G

H T

SEMI-RECESSED FIRE EXTINGUISHER /

ESTINTORE SEMI-INCASSATO

TOILET FIXTURES & ACCESSORIES /

ACCESSORI SERVIZI IGIENICI

KNEE SPACE /

SPAZIO PER LE

GAMBE

38 SPAZIO VUOTO

38 GAP /

610 MIN 305 MIN

915mm REAR WALL

GRAB BAR /

MANIGLIONE PARETE

POSTERIORE 915mm

1065mm SIDE WALL

GRAB BAR /

MANIGLIONE PARETE

LATERALE 1065mm

1065mm SIDE WALL

GRAB BAR /

MANIGLIONE

PARETE LATERALE

1065mm

230 MAX

180 MIN

1220 MAX

610 MIN

SANITARY NAPKIN

DISPOSAL

/RACCOLTA

SALVIETTE USA E

GETTA

T/ O

G R

IP

PI

N G

S U

R

FA

C E

M

IN

M

AX

" M

AX

" M

IN

915 MAX

CL

CL

305 MAX 1065 MIN

CLEAR

FLOOR

SPACE /

SPAZIO

LIBERO

PAVIMENTO

M

IN

- 6

760 MIN

M

IN

M

IN

M

AX

635 MAX

280 MIN

M

AX

L

AV

AT

O R

IE

S

M

IN

A

LL

A

PA

R

TE

S U

P.

D

EL

V

ET

R

O

M

IN

T

O T

G

LA

SS

M

AX

T/ O

O

PE

R

AB

LE

P

AR

TS

M

AX

M

IN

M

IN 23

M

IN

T/ O

O

PE

R

AB

LE

P

AR

TS

M

AX

LIGHT SWITCH /

INTERRUTTORE

LUCE

150 MAX

M

AX

405 - 455

990 - 1040

M

IN

- 1

CL

DRINKING FOUNTAINS /

FONTANELLE ACQUA POTABILE

SIDE VIEW / VISTA LATERALE

EDGE OF WALL

BEYOND / BORDO

DEL MURO

RETROSTANTE

M

IN

0 68

M

IN

FRONT VIEW (DOUBLE) / VISTA

FRONTALE (DOPPIO)

ABA

COMPLIANT

EWC / EWC

CONFORME

ALL'ABA

FACE OF

ADJACENT

WALL /

SUPERFICIE

DEL MURO

ADIACENTE

MIN

CL 96

- 1

MIN

MAX

125 MAX

TO

S

PO

U

T / A

LL

O

S C

AR

IC

O

M

AX

M

AX

380 MIN

MIN

MIN

MIN

A

LL

A S

U P

E R

FI

C

IE

D

I P R

ES

LL

E C

O M

P O

N

EN

TI

IN

U S

O

M

AX

A I L

AV

AB

I

M

AX

N

O N

O

ST

R (N

O N

A L

LA

VA

BO

AL

LE

C O

M

PO

N

EN

TI

IN

U

SO

M

AX

A L

FO

N

D

SPAZIO LIBERO PAVIMENTO SPAZIO LIBERO PAVIMENTO

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:1

P M

T Y

P

IC

A L

F

IX

T U

R E

M O

U N

T

IN

G H

E

IG

H T

A-003

A L

T E

Z Z

E T

IP

IC

H E

D I

M O

N T

A G

G

IO

D E

G L

I

IM

P

IA

N T

I

14125458

KMC

N. 1 Ø

PVC RIGID CONDUIT

BUILDING 73003 /

EDIFICIO 73003

MECHANICAL YARD /

LOCALE MECCANICO

PARKING /

PARCHEGGIO

BUILDING 7300 /

EDIFICIO 7300

MECHANICAL YARD /

LOCALE MECCANICO

1:300

0 1 2 3 4 5 10 20 30

SCALE: SCALE:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:1

P M

A R

C H

IT

E

C T

U R

A L

S

IT

E

P L

A

AS101

P

IA

N T

A A

R C

H

IT

E T

T O

N

IC

A D

E L

S

IT

O

14125459

KMC

SCALE:1 : 300

ARCHITECTURAL SITE PLAN / PIANTA ARCHITETTONICA DEL SITO

TRUE

NORTH

NOTES - SITE PLANS

1 REFER TO CIVIL DRAWINGS FOR HORIZONTAL CONTROL DIMENSIONS / FARE

RIFERIMENTO AI DISEGNI CIVILI PER DIMENSIONI DI CONTROLLO ORIZZONTALI

2 REFER TO CIVIL DRAWINGS FOR SITE DIMENSIONS / FARE RIFERIMENTO AI

DISEGNI CIVILI PER DIMENSIONI DEL SITO

x1 x2 x3 x4 x5 x6 x7 x8 x9 x10 x11 x12 xK xJ xH xG xF xE xD xC xL

AD111

B3

SIMULATOR

SERVER ROOM / AHU

MISSION PLANNING

ROOM

MISSION BRIEFING

ROOM

TEL / DATA

COMSEC

DUTY DESK 041

ARMORY

FLIGHT OPERATIONS

SUITE

FLIGHT

COMMANDER'S

OFFICE

FLIGHT OPERATIONS

SUITE

FLIGHT

COMMANDER'S

OFFICE

CORRIDOR

EQUIPMENT ROOM

DIRECTOR

OPERATIONS OFFICE

OPERATIONS SUP.

OFFICE

TALO OFFICE

SCHEDULING AREA

EVALUATION AREA

TRAINING AREA 059

ADMINISTRATION

SUITE

IN. MGT.

COMMANDER'S

BRIEFING

1ST SGT. OFFICE

COMMANDER'S

OFFICE

COMMANDER'S

SECRETARY AREA

VEST.

LOBBY

HERITAGE ROOM

RUDITORIUM

MECHANICAL ROOM

FIRE PUMP

BREAK ROOM

CORRIDOR

UNISEX ADA TOILET

WOMEN

CONFERENCE ROOM

MEN

JAN / LAUN

VEST.

CORRIDOR

SWITCHGEAR

FITNESS ROOM

RADIO MAINTENANCE

WORK CENTER

RADIO MAINTENANCE

OFFICE

MAINT. SUP. OFFICE

RADIO VEHICLE

MAINTENANCE BAY

014.1

MAINTENANCE BAY

ACCESS 2

VEHICLE

MAINTENANCE BAY

UNIT MOBILITY BAG

STORAGE

BATTERY ROOM

MOBILITY READINESS

SPARE PARTS

STORAGE (MRSP)

RADIO MAINT. FIELD

EQUIP STORAGE

40 128 16

1:200

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:0

P M

O V

E R

A L

L

G R

O U

N D

F L

O O

R D

E M

O L

IT

IO

N P

L A

AD110

P

IA

N T

A D

E M

O L

IZ

IO

N E

P

IA

N O

T E

R R

A

G E

N E

R A

L E

14125460

KMC

SCALE: 1 : 200

OVERALL - DEMOLITION GROUND FLOOR PLAN /

GENERALE - PLANIMETRIA PIANO TERRA DEMOLIZIONE

x1 x2 x3 x4 xJ xH

D1

D1

D2 D2 D3

D3 D4

D4 D4

11785 VIF

D5

D7D7

160 ± 2694 VIF

VIF

301 184 ±D7

D7

230 ±

D7 585 ± 308 VIF

D7

D7

D4

D9

D10

SIMULATOR

SERVER ROOM / AHU

LIBRARY / BIBLIOTECA

MISSION PLANNING

ROOM

MISSION BRIEFING

ROOM

TEL / DATA045

VESTIBULE /

VESTIBOLO

CORRIDOR

VESTIBULE /

VESTIBOLO

E Q

U

IP

M E

N T

R O

O M

D

IR

E C

T O

R O

P E

R A

T

IO

N S

O F

F

IC

E

O P

E R

A T

IO

N

S S

U P

O

F F

IC

E

TALO OFFICE

SCHEDULING AREA

FLIGHT OPERATIONS

SUITE041

ARMORY

DUTY DESK

COMSEC

FLIGHT

COMMANDER'S

OFFICE

D6

D13

D13

D16

D16

D16 x1 x2 x3 x4 xJ xH

SERVER ROOM / AHU

LIBRARY / BIBLIOTECA

MISSION PLANNING

ROOM

MISSION BRIEFING

ROOM

CORRIDOR

VESTIBULE /

VESTIBOLO

DUTY DESK

ARMORY

COMSEC

TEL / DATA

FLIGHT

COMMANDER'S

OFFICE

D11

D11

D8

D12

1:100

0 1 32 4 5 10

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:0

P M

D E

M O

L

IT

IO

N

G R

O U

N D

F L

O O

R P

L A

AD111

P

IA

N T

A D

E M

O L

IZ

IO

N E

P

IA

N O

T E

R R

A

A G

G

IU

N T

A

14125461

KMC

SCALE: 1 : 100 SCALA: 1 : 100

DEMOLTION GROUND FLOOR PLAN / GENERALE - PLANIMETRIA PIANO TERRA DEMOLIZIONE

B3

KEYNOTES / NOTE PRINCIPALI

D1 DEMOLISH DOOR, HARDWARE, AND FRAME / DEMOL. PORTA, MINUTERIA E

TELAIO

D2 DEMOLISH CONCRETE PAD, SEE C-SERIES / DEMOL. BASE CALCESTRUZZO,

VEDERE SERIE C

D3 DEMOLISH RAMP, SEE C-SERIES / DEMOL. RAMPA, VEDERE SERIE C

D4 DEMOLISH GUARD AND RAIL / DEMOL. RIPARO E RINGHIERA

D5 DEMOLISH CONCRETE WING WALL AND FOUNDATION / DEMOL. FONDAMENTA E

PARETE CALCESTRUZZO

D6 REFER TO ELECTRICAL DRAWINGS FOR DEMOLTION OF ELECTRICAL ITEMS

ATTACHED TO WALL / FARE RIFERIMENTO AI DISEGNI ELETTRICI PER LA

DEMOLIZIONE DELLE PARTI ELETTRICHE INSERITE NEL MURO

D7 CUT OUT PORTION OF PLASTER BAND TO FACE OF WALL. COORDINATE

LOCATION AND LENGTH OF CUT WITH NEW WALL LOCATIONS./ TAGLIARE

PARTE DELLA BANDA IN GESSO ALLA SUPERFICIE DELLA PARETE.

COORDINARE POSIZIONE E LUNGHEZZA DI TAGLIO RISPETTO A NUOVE

UBICAZIONI SULLA PARETE

D8 DEMOLISH EXTERIOR SUN SHADE / DEMOLIRE PARASOLE ESTERNO

D9 CUT PORTION OF EXTERIOR WINDOW SILL TO COORDINATE WITH

INSTALLATION OF RATED SHAFT WALL INFILL. / PORZIONE DEL DAVANZALE

ESTERNO DELLA FINESTRA DA COORDINARE CON L'INSTALLAZIONE DELLA

PARETE CLASSIFICATA DI TAMPONAMENTO

D10 REMOVE WINDOW OPERATING HARDWARE / RIMUOVERE MINUTERIA FINESTRA

D11 COORDINATE CEILING DEMOLITION WITH INSTALLATION OF FIRE PROTECTION

PIPING. SEE FIRE PROTECTION DRAWINGS / COORDINARE LA DEMOLIZIONE DEL

SOFFITTO CON L'ISTALLAZIONE DELLE TUBAZIONUI PER LA PROTEZIONE

ANTINCENDIO. VEDERE TAVOLE PROTEZIONE ANTINCENDIO

D12 COORDINATE CEILING DEMOLITION WITH CONSTRUCTION OF NEW 1A0.4

PARTITION / COORDINAMENTO DELLA DEMOLIZIONE DEL SOFFITTO CON

REALIZZAZIONE DI NUOVA TRAMEZZATURA 1A0.4

D13 DEMOLISH DOWNSPOUT / DEMOLIZIONE PLUVIALE

D16 REMOVE RADON EXHAUST VENT COVER / RIMOZIONE COPERCHIO

VENTILAZIONE DI SCARICO RADON

SCALE: 1 : 100 SCALA: 1 : 100

DEMOLITION - GROUND FLOOR REFLECTED CEILING PLAN /

DEMOLIZIONE - PLANIMETRIA DEL SOFFITTO RIFLESSO AL PIANO TERRA

A1 xJ xH xG xF xE xD xC xL

D8

20330 ±

D14

D15

40 128 16

1:200

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:0

P M

R O

O F

D E

M O

L

IT

IO

N

P L

A

AD121

P

IA

N T

A D

E M

O L

IZ

IO

N E

C O

P E

R T

U R

A

14125462

KMC

SCALE: 1 : 200

ROOF DEMOLITION PLAN / PLANIMETRIA DEMOLIZIONE TETTO

KEYNOTES / NOTE PRINCIPALI

D8 DEMOLISH EXTERIOR SUN SHADE / DEMOLIRE PARASOLE ESTERNO

D14 PERFORM SELECTIVE DEMOLITION AT CLAY TILES TO CONFIRM CONDITION

BELOW TILES / ESECUZIONE DI UNA DEMOLIZIONE SELETTIVA DELLE TEGOLE IN

ARGILLA PER LA CONFERMA DELLE CONDIZIONI SOTTO DI ESSE

D15 DEMOLISH WOOD NAILING STRIPS. COORDINATE EXTENT OF DEMOLITION WITH

APPLICATION OF NEW ICE AND WATER SHIELD. SEE A-511. / DEMOLIZIONE DI

BANDELLE DI CHIODATURA IN LEGNO. COORDINAMENTO DELL'ESTENSIONE

DELLA DEMOLIZIONE CON APPLICAZIONE DI NUOVA SCHERMATURA PER

GHIACCIO E ACQUA. VEDERE A-511.

xJ xH xG xF xE xD xC xL

SIMULATOR

SERVER ROOM / AHU

LIBRARY / BIBLIOTECA

M U

L T

I- P

U R

P O

S E

R O

O M

B

S A

L A

M U

L T

IF

U

N Z

IO

N

E B

M U

L T

I- P

U R

P O

S E

R O

O M

A

S A

L A

M U

L T

IF

U

N Z

IO

N

E A

SPARES STORAGE

ROOM / LOCALE

STOCCAGGIO RICAMBI

MISSION PLANNING /

LIBRARY /

PIANIFICAZIONE

MISSIONE /

BIBLIOTECA

UNISEX LATRINE /

SERVIZI IGIENICI

UNISEX

ELECTRICAL /

ELETTRICA

MECHANICAL /

MECCANICA

AVDTT / AVDTT

MAINTENANCE OFFICE

/ UFFICIO

MANUTENZIONE

VESTIBULE /

VESTIBOLO

TELECOM / TELECOM

MISSION PLANNING

ROOM

MISSION BRIEFING

ROOM

VESTIBULE /

VESTIBOLO

TEL / DATA

COMSEC

DUTY DESK

ARMORY

FLIGHT

COMMANDER'S

OFFICE

FLIGHT OPERATIONS

SUITE

CORRIDOR

FLIGHT OPERATIONS

SUITE

FLIGHT

COMMANDER'S

OFFICE

HERITAGE ROOM

VESTIBULE /

VESTIBOLO

EQUIPMENT ROOM

DIRECTOR

OPERATIONS OFFICE

OPERATIONS SUP.

OFFICE

TALO OFFICE

SCHEDULING AREA

EVALUATION AREA

TRAINING AREA

ADMINISTRATION

SUITE

IN. MGT.

COMMANDER'S

BRIEFING

1ST SGT. OFFICE

COMMANDER'S

OFFICE

COMMANDER'S

SECRETARY AREA 001

VEST.

RUDITORIUM

BREAK ROOM

CHAIR STORAGE

AV EQUIPMENT

FIRE PUMP066

CORRIDOR

LOBBY

TELE.

ELEC.

COAT CLOSET

C O

R R

ID

O

R

WOMEN

UNISEX ADA TOILET

MEN

JAN / LAUN

VEST.

MAINT. SUP. OFFICE

RADIO MAINTENANCE

OFFICE

RADIO MAINTENANCE

WORK CENTER

CONFERENCE ROOM

MECHANICAL ROOM

SWITCHGEAR

FITNESS ROOM

RADIO VEHICLE

MAINTENANCE BAY

VEHICLE

MAINTENANCE BAY

014.1

MAINTENANCE BAY

ACCESS 2

RADIO MAINT. FIELD

EQUIP STORAGE

MOBILITY READINESS

SPARE PARTS

STORAGE (MRSP)

UNIT MOBILITY BAG

STORAGE

BATTERY ROOM

OFT SIMULATOR BAY /

BAIA SIMULATORE

OFT

SIMULATOR MX / TOOL

STORAGE / ICS

SUPPORT /

SIMULATORE MX /

MAGAZZINO

STRUMENTI /

SUPPORTO ICS

COMPUTER / IG /

COMPUTER /IG

CORRIDOR /

CORRIDOIO

BOILER / CALDAIA

A-201 B1

A-201 C1

A-201 A1

A-201 D1

C1 A-301

C1 A-301

B1 A-301

B1 A-301

A1 A-301

A1 A-301

876543

C

D

E

F

H

A-111 A1

94'21

I

G

B

A

JAN / SERVIZIO

40 128 16

1:200

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:1

P M

O V

E R

A L

L

G R

O U

N D

F L

O O

R P

L A

A-110

P L

A N

IM

E

T R

IA

P

IA

N

O T

E R

R A

G

E N

E R

A L

E

14125463

KMC

SCALE: 1 : 200

OVERALL - GROUND FLOOR PLAN / GENERALE - PLANIMETRIA PIANO TERRA

NOTES - FLOOR PLANS / NOTE - PLANIMETRIE PIANI

1 REFER TO SHEET A-001 FOR GENERAL NOTES AND SYMBOLS / FARE

RIFERIMENTO AL FOGLIO A-001 PER LE NOTE GENERALI E I SIMBOLI

2 REFER TO A-112 FOR PARTITION TYPE TAGS / FARE RIFERIMENTO A A-112 PER

LE ETICHETTE DEL TIPO DI TRAMEZZATURA

3 REFER TO SHEET A-601 FOR PARTITION TYPES / FARE RIFERIMENTO AL

FOGLIO A-601 PER I TIPI DI TRAMEZZATURE

4 REFER TO ENLARGED PLANS AND INTERIOR ELEVATIONS FOR ADDITIONAL

INFORMATION / FARE RIFERIMENTO ALLE PLANIMETRIE AMPLIATE E ALLE

ALTEZZA INTERNE PER MAGGIORI INFORMAZIONI

5 REFER TO MECHANICAL DRAWINGS FOR ALL HEATING VENTILATION AND AIR

CONDITIONING EQUIPMENT LOCATIONS AND REQUIREMENTS / FARE

RIFERIMENTO AI DISEGNI MECCANICI PER LE POSIZIONI E I REQUISITI DI

TUTTE LE APPARECCHIATURE DI CONDIZIONAMENTO DELL'ARIA E DI

VENTILAZIONE PER RISCALDAMENTO

6 REFER TO ELECTRICAL DRAWINGS FOR ALL POWER, LIGHTING AND

ELECTRICAL EQUIPMENT LOCATIONS AND REQUIREMENTS / FARE

RIFERIMENTO AI DISEGNI ELETTRICI PER LE POSIZIONI E I REQUISITI DI TUTTE

LE APPARECCHIATURE ELETTRICHE DI ALIMENTAZIONE E ILLUMINAZIONE

7 REFER TO LOW VOLTAGE DRAWINGS FOR ALL COMMUNICATION EQUIPMENT

LOCATIONS AND REQUIREMENTS / FARE RIFERIMENTO AI DISEGNI BASSA

TENSIONE PER LE POSIZIONI E I REQUISITI DI TUTTE LE APPARECCHIATURE DI

COMUNICAZIONE

8 DIMENSIONS SHOWN ARE TO FINISH FACE OF WALL - TYPICAL UNLESS NOTED

OTHERWISE / LE DIMENSIONI INDICATE FANNO RIFERIMENTO ALLA

SUPERFICIE DELLA PARETE FINITA - STANDARD SE NON SPECIFICATO

DIVERSAMENTE

9 LOCATE DOORS 100mm FROM HINGE SIDE OF WALL, TYPICAL UNLESS NOTED OTHERWISE / PORTE INSTALLATE 100mm DAL LATO DEI CARDINI DEL MURO, STANDARD SE NON SPECIFICATO DIVERSAMENTE

10 DIMENSIONS MARKED AS "CLEAR" INDICATE THE CLEAR DIMENSION FROM

FINISH TO FINISH / LE QUOTE CONTRASSEGNATE COME “LIBERE” INDICANO LA

QUOTA LIBERA DA FINITURA A FINITURA

11 WHERE FIRE RATED PARTITIONS INTERSECT WITH LESSER RATED

PARTITIONS, CONTINUE THE HIGHER RATED PARTITION THROUGH THE

INTERSECTION TO MAINTAIN THE HIGHER RATING / LADDOVE I TRAMEZZI

RESISTENTI AL FUOCO INCROCIANO TRAMEZZI CON RESISTENZA INFERIORE,

PROSEGUIRE LA TRAMEZZATURA A RESISTENZA MAGGIORE ATTRAVERSO

L'INTERSEZIONE , IN MODO DA CONSERVARE IL LIVELLO PIÙ ELEVATO

DN

DN

x1 x2 x3 x4 xJ xH

A-211 C1

FLIGHT OPERATIONS

SUITE

FLIGHT

COMMANDER'S

OFFICE

ARMORY

DUTY DESK

COMSEC

TEL / DATA

VESTIBULE /

VESTIBOLO

MISSION BRIEFING

ROOM

MISSION PLANNING

ROOM

SERVER ROOM / AHU

LIBRARY / BIBLIOTECA

SIMULATOR

VESTIBULE /

VESTIBOLO

EQUIPMENT ROOM

DIRECTOR

OPERATIONS OFFICE

OPERATIONS SUP.

OFFICE

TALO OFFICE

SCHEDULING AREA

EVALUATION AREA

CORRIDOR

VESTIBULE /

VESTIBOLO

CORRIDOR /

CORRIDOIO

TELECOM / TELECOM

MECHANICAL /

MECCANICA

MAINTENANCE OFFICE

/ UFFICIO

MANUTENZIONE

AVDTT / AVDTT

MULTI-PURPOSE

ROOM A / SALA

MULTIFUNZIONE A

MULTI-PURPOSE

ROOM B /

SALA

MULTIFUNZIONE

B

SPARES STORAGE

ROOM / LOCALE

STOCCAGGIO RICAMBI

MISSION PLANNING /

LIBRARY /

PIANIFICAZIONE

MISSIONE /

BIBLIOTECA

UNISEX LATRINE /

SERVIZI IGIENICI

UNISEX

ELECTRICAL /

ELETTRICA

OFT SIMULATOR BAY /

BAIA SIMULATORE

OFT

SIMULATOR MX / TOOL

STORAGE / ICS

SUPPORT /

SIMULATORE MX /

MAGAZZINO

STRUMENTI /

SUPPORTO ICS

COMPUTER / IG /

COMPUTER /IG

BOILER / CALDAIA

A2 A-311

A3 A-312

A3 A-311

C2 A-311

A-211 A1

A-212 C2

A-212 A1

A1 A-302

A1 A-302

C1 A-302

C1 A-302

C4 A-302

C4 A-302

A1 A-311

A2 A-312

075 074

083082

079078

070071

076B 076C

876543

C

D

E

F

H

94'21

I

G

B

A

076A

JAN / SERVIZIO

A-401 B3

D1

AR111

A-501 C4

A-501 C2

A-501 A1

A-501 A4

6065 140 18300 655

215 18170 215 26215 140

2130 1940 2130 6200 6200 11685 1260 10605 2805

5190 4825 3475 2875 1260 8885

A-401 B1

3550 1245 1640 5465 3125 1635 655

6530 5350 3695 1080 1855

A-501 C1

A-401 C1

A-401 C2

A-401 C4

A-501 A2

A-611 A4

A-611 A5

ALIGN /

ALLINEAMENTO

12 12

4 4

979797

97 9797

3775 100

A3 A-514

A-402 A1

A-501 B1

A-501 B1

OPP

47 111111

A4 A-514

610 ± 600 ±

700 ±

C3

A-512 SIM

C3

A-512 SIM

ALIGN /

ALLINEAMENTO

140140

1:100

0 1 32 4 5 10

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:2

P M

A D

D

IT

IO

N

G

R O

U N

D F

L O

O R

D

IM

E N

S

IO

N P

L A

A-111

P L

A N

IM

E

T R

IA

Q

U O

T A

T A

P

IA

N O

T E

R R

A

A G

G

IU

N T

A

14125464

KMC

NOTES - FLOOR PLANS / NOTE - PLANIMETRIE PIANI

1 REFER TO SHEET A-001 FOR GENERAL NOTES AND SYMBOLS / FARE

RIFERIMENTO AL FOGLIO A-001 PER LE NOTE GENERALI E I SIMBOLI

2 REFER TO A-112 FOR PARTITION TYPE TAGS / FARE RIFERIMENTO A A-112 PER

LE ETICHETTE DEL TIPO DI TRAMEZZATURA

3 REFER TO SHEET A-601 FOR PARTITION TYPES / FARE RIFERIMENTO AL

FOGLIO A-601 PER I TIPI DI TRAMEZZATURE

4 REFER TO ENLARGED PLANS AND INTERIOR ELEVATIONS FOR ADDITIONAL

INFORMATION / FARE RIFERIMENTO ALLE PLANIMETRIE AMPLIATE E ALLE

ALTEZZA INTERNE PER MAGGIORI INFORMAZIONI

5 REFER TO MECHANICAL DRAWINGS FOR ALL HEATING VENTILATION AND AIR

CONDITIONING EQUIPMENT LOCATIONS AND REQUIREMENTS / FARE

RIFERIMENTO AI DISEGNI MECCANICI PER LE POSIZIONI E I REQUISITI DI

TUTTE LE APPARECCHIATURE DI CONDIZIONAMENTO DELL'ARIA E DI

VENTILAZIONE PER RISCALDAMENTO

6 REFER TO ELECTRICAL DRAWINGS FOR ALL POWER, LIGHTING AND

ELECTRICAL EQUIPMENT LOCATIONS AND REQUIREMENTS / FARE

RIFERIMENTO AI DISEGNI ELETTRICI PER LE POSIZIONI E I REQUISITI DI TUTTE

LE APPARECCHIATURE ELETTRICHE DI ALIMENTAZIONE E ILLUMINAZIONE

7 REFER TO LOW VOLTAGE DRAWINGS FOR ALL COMMUNICATION EQUIPMENT

LOCATIONS AND REQUIREMENTS / FARE RIFERIMENTO AI DISEGNI BASSA

TENSIONE PER LE POSIZIONI E I REQUISITI DI TUTTE LE APPARECCHIATURE DI

COMUNICAZIONE

8 DIMENSIONS SHOWN ARE TO FINISH FACE OF WALL - TYPICAL UNLESS NOTED

OTHERWISE / LE DIMENSIONI INDICATE FANNO RIFERIMENTO ALLA

SUPERFICIE DELLA PARETE FINITA - STANDARD SE NON SPECIFICATO

DIVERSAMENTE

9 LOCATE DOORS 100mm FROM HINGE SIDE OF WALL, TYPICAL UNLESS NOTED OTHERWISE / PORTE INSTALLATE 100mm DAL LATO DEI CARDINI DEL MURO, STANDARD SE NON SPECIFICATO DIVERSAMENTE

10 DIMENSIONS MARKED AS "CLEAR" INDICATE THE CLEAR DIMENSION FROM

FINISH TO FINISH / LE QUOTE CONTRASSEGNATE COME “LIBERE” INDICANO LA

QUOTA LIBERA DA FINITURA A FINITURA

11 WHERE FIRE RATED PARTITIONS INTERSECT WITH LESSER RATED

PARTITIONS, CONTINUE THE HIGHER RATED PARTITION THROUGH THE

INTERSECTION TO MAINTAIN THE HIGHER RATING / LADDOVE I TRAMEZZI

RESISTENTI AL FUOCO INCROCIANO TRAMEZZI CON RESISTENZA INFERIORE,

PROSEGUIRE LA TRAMEZZATURA A RESISTENZA MAGGIORE ATTRAVERSO

L'INTERSEZIONE , IN MODO DA CONSERVARE IL LIVELLO PIÙ ELEVATO

SCALE: 1 : 100 SCALA: 1 : 100

ADDITION - GROUND FLOOR DIMENSIONS PLAN / AGGIUNTA - PLANIMETRIA QUOTE PIANO TERRA

A1

KEYNOTES / NOTE PRINCIPALI

4 PREFINISHED 100mm DIA. METAL DOWNSPOUT / GRONDAIA METALLICA DIAM.

100mm PREFINITA

8 CONCRETE FILLED PAINTED STEEL PIPE BOLLARD, SEE CIVIL / TUBO

DISSUASORE RIVESTITO IN ACCIAIO CON RIEMPIMENTO CEMENTIZIO, VEDI CIVL

9 PATCH WALL LEFT EXPOSED FROM DOOR FRAME REMOVAL / PARTE DI MURO

ESPOSTA DOPO LA RIMOZIONE DEL TELAIO DELLA PORTA

11 ACCORDION PARTITION WALL / TRAMEZZO A FISARMONICA

12 FLOOR TRENCH / SCAVO PAVIMENTO

13 RAISED ACCESS FLOOR 600x600/ PIANO D'ACCESSO RIALZATO 600x600

14 RIBBED CONCRETE SYSTEM, SEE STRUCTURAL DWGS / SISTEMA

CALCESTRUZZO NERVATO, VEDI STR.

15 SLAB, SEE STRUCTURAL DWGS / SOLETTA, VEDI STR.

16 APPLY BLACK-OUT FILM TO OFFICE SIDE OF GLAZING / APPLICARE PELLICOLA

OSCURANTE AL LATO UFFICIO DELLA VETRATA

17 WALL-MOUNTED FIRE EXTINGUISHER / ESTINTORE A MURO

18 FIRE EXTINGUISHER CABINET / ARMADIETTO ESTINTORE

24 SEAL OPENINGS IN EXISTING WALL WITH MIN 2 HOUR FIRE STOPPING /

SIGILLARE LE APERTURE NEL MURO ESISENTE CON MATERIALE RESISTENTE

AL FUOCO PER ALMENO 2 ORE

47 FIRE HOSE CABINET / CABINA MANICHETTE ANTINCENDIO

97 SIMULATOR EQUIPMENT, NOT IN CONTRACT / APPARECCHIATURE SIMULATORE,

ESCLUSE DALL'APPALTO

110 PATCH HOLES LEFT FROM REMOVAL OF WALL-MOUNTED EQUIPMENT /

RIEMPIRE I BUCHI RIMANENTI DOPO LA RIMOZIONE DELL'ATTREZZATURA

MONTATA A PARETE

111 CHAIN LINK FENCE, SEE CIVIL / RECINZIONE A CATENA, VEDI CIVIL

140 CONCRETE FILLED PAINTED STEEL PIPE BOLLARD, SEE 05 50 13 / TUBO

DISSUASORE RIVESTITO IN ACCIAIO CON RIEMPIMENTO CEMENTIZIO, VEDI 05

50 13

DN

x1 x2 x3 x4 xK xJ xH

876543

C

D

E

F

H

94'21

I

G

B

A

FLIGHT OPERATIONS

SUITE

FLIGHT

COMMANDER'S

OFFICE

ARMORY

DUTY DESK

COMSEC

TEL / DATA045

VESTIBULE /

VESTIBOLO

MISSION BRIEFING

ROOM

MISSION PLANNING

ROOM

SERVER ROOM / AHU

LIBRARY / BIBLIOTECA

SIMULATOR

VESTIBULE /

VESTIBOLO

EQUIPMENT ROOM

DIRECTOR

OPERATIONS OFFICE

OPERATIONS SUP.

OFFICE

TALO OFFICE

SCHEDULING AREA

EVALUATION AREA

CORRIDOR

VESTIBULE /

VESTIBOLO

CORRIDOR /

CORRIDOIO

TELECOM / TELECOM

MECHANICAL /

MECCANICA

MAINTENANCE OFFICE

/ UFFICIO

MANUTENZIONE

AVDTT / AVDTT

MULTI-PURPOSE

ROOM A / SALA

MULTIFUNZIONE A

MULTI-PURPOSE

ROOM B /

SALA

MULTIFUNZIONE

B

SPARES STORAGE

ROOM / LOCALE

STOCCAGGIO RICAMBI

MISSION PLANNING /

LIBRARY /

PIANIFICAZIONE

MISSIONE /

BIBLIOTECA

UNISEX LATRINE /

SERVIZI IGIENICI

UNISEX

ELECTRICAL /

ELETTRICA076

OFT SIMULATOR BAY /

BAIA SIMULATORE

OFT

SIMULATOR MX / TOOL

STORAGE / ICS

SUPPORT /

SIMULATORE MX /

MAGAZZINO

STRUMENTI /

SUPPORTO ICS

COMPUTER / IG /

COMPUTER /IG

BOILER / CALDAIA

075 074

083082

070071

076B 076C

1A2.4

1A2.4a 1A2.4

1A2.4a

1A0.4a

1A2.4b

3A0.4

3A0.3

1A0.4b

1A0.4b

1A1.4

3A0.3

1A0.4b1A0.4b

1A0.4b

1A0.4a1A0.4a

3A0.33A0.3 3A0.33A0.3

076A

JAN / SERVIZIO

7A1.13 3B0.3

3A0.63A0.33A0.3

3A0.33A0.3

1A1.4

1A1.4b

3A0.6

3B0.3

3B0.3

3B0.3

7A1.13

3A0.3

3A0.43A0.4

1A0.4b 1A2.4a1A2.4a 1A0.4a

1A2.4

3A0.3

3A0.3

3A0.3

1A1.4b

1A2.4a

1A2.4a

1A2.4

2A2.2a

3A0.3 3A0.3

3A0.3

1A0.4

1C0.41C0.4

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:2

P M

A D

D

IT

IO

N

G

R O

U N

D F

L O

O R

P A

R T

IT

IO

N S

P L

A

A-112

P

IA

N T

A T

R A

M E

Z Z

I P

IA

N

O T

E R

R A

A

G G

IU

N

T A

14125465

KMC

SCALE: 1 : 100 SCALA: 1 : 100

ADDITION - GROUND FLOOR PLAN - PARTITION TAGS /

AGGIUNTA - PLANIMETRIA PIANO TERRA - ETHICHETTE TRAMEZZI

A1

SCALE:1:100

2M 4M 8M

A-121 A1

A-122 A1

40 128 16

1:200

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:2

P M

O V

E R

A L

L

R O

O F

P L

A

A-120

P

IA

N T

A D

E L

L A

C O

P E

R T

U R

A

G E

N E

R A

L E

14125466

KMC

SCALE: 1 : 200

OVERALL - ROOF PLAN / GENERALE - PLANIMETRIA TETTO

A2 A-311

A3 A-312

A3 A-311

C2 A-311

A1 A-302

A1 A-302

C1 A-302

C1 A-302

C4 A-302

C4 A-302

A1 A-311

A1 A-312

A2 A-312

C3 A-513

876543

C

D

E

F

H 20

94'21

I

G

B

A

A3 A-513

A4 A-513

C1 A-512

C1 A-511

% 5

% 1

A3 A-511

2121 2121

58 58 58 58

%10 10 10 10 10

VI

F

20230 ± VIF

B2 A-514

A-121 D1

20% 20%

C4 A-514

G

B1 A-514

A1 A-514

800 ±

20%

20%

U N

P

AN

N

EL

LO

O N

E

TI

LE

1:100

0 1 32 4 5 10

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-A

.r v t

/6

/2

:2

:3

P M

A D

D

IT

IO

N

R

O O

F P

L A

A-121

P

IA

N T

A D

E L

L A

C O

P E

R T

U R

A

A G

G

IU

N T

A

14125467

KMC

SCALE: 1 : 100 SCALA: 1 : 100

ADDITION - ROOF PLAN / AGGIUNTA - PLANIMETRIA TETTO

A1

KEYNOTES / NOTE PRINCIPALI

1 PREFINISHED 150mm FABRICATED METAL STANDING SEAM ROOF ASSEMBLY /

ASSEMBLAGGIO DI TETTI IN LAMIERA PREFABBIRCATI A GIUNTO AGGRAFFATO

PREFINITI E CON SPESSORE DI 150mm

2 PREFINISHED 200mm METAL GUTTER / GRONDAIA METALLICA 200mm PREFINITA

5 CLAY TILE ROOF / TETTO IN TEGOLE

10 ROOF DRAIN / SCARICO DEL TETTO

20 EXPANSION JOINT / GIUNTO DI DILATAZIONE

21 SLOPED CONCRETE BEAM ABOVE ROOF PLANE, SEE STRUCTURAL / TRAVE

INCLINATA IN CALCESTRUZZO SOPRA AL PIANO DEL TETTO, VEDERE

STRUTTURALE

22 EXISTING ROOF / TETTO ESISTENTE

23 SINGLE-PLY MEMBRANE ROOF / TETTO A MEMBRANA SINGOLA

58 OVERFLOW ROOF DRAIN / SCARICO DEL TETTO TROPPOPIENO

121 LADDER / SCALA

NOTES - ROOF PLANS / NOTE - PLANIMETRIE TETTO

1 REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR

ADDITIONAL ROOF ELEMENT INFORMATION / FARE RIFERIMENTO AI DISEGNI

DELLE PARTI MECCANICHE, IDRAULICHE ED ELETTRICHE PER MAGGIORI

INFORMAZIONI SUGLI ELEMENTI DEL TETTO

2 COORDINATE EXACT LOCATION OF ROOF DRAINING TO ENSURE NO

INTERFERENCE WITH ANY STRUCTURAL MEMBERS. / L'APPALTATORE DEVE

COORDINARE LA POSIZIONE ESATTA DEGLI SCARICHI DEL TETTO IN MODO DA

NON INTERFERIRE CON I COMPONENTI STRUTTURALI - I PLUVIALI DEVONO

ESSERE POSIZIONATI NEL PUNTO E CON LA PENDENZA RICHIESTI DALLE

NORMATIVE APPLICABILI

3 VERIFY AND COORDINATE EXACT LOCATIONS OF PENETRATIONS TO AVOID

INTERFERENCE WITH MAJOR STRUCTURAL MEMBERS.

This is the start of the file's text. The full file is on GovTribe.