Text version
1. ACI 318-19 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE
2. UFC 1-200-01 DOD BUILDING CODE, WITH CHANGE 1 (OCTOBER 1, 2020)
3. FC 1-300-09N NAVY AND MARINE CORPS DESIGN PROCEDURES, WITH
CHANGE 6 (JULY 9, 2021)
4. UFC 3-301-01 STRUCTURAL ENGINEERING (OCTOBER 1, 2019)
5. UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS,
WITH CHANGE 1 (AUGUST 19, 2020)
6. ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES
7. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION FOR
THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR
BUILDINGS, FIFTEENTH EDITION
8. AWS STRUCTURAL WELDING CODE (2015 EDITION)
9. ACI 350/350R-06 CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING
CONCRETE STRUCTURES
10. D.M., CONSTRUCTION CODE (17 JANUARY 2018)
11. CIRCOLARE DEL 21 GENNAIO 2019 N. 7. INSTRUCTIONS FOR THE
APPLICATION OF THE UPDATE OF THE TECHNICAL STANDARDS FOR
CONSTRUCTION REFERRED TO IN THE MINISTERIAL DECREE OF 17 JANUARY
12. LAW N. 1086, NORMS RELATED TO NORMAL AND PRE-STRESSED
REINFORCED CONCRETE STRUCTURES AND STEEL STRUCTURES (5
NOVEMBER 1971)
13. LAW N. 64, PROVISIONS FOR STRUCTURES, WITH SPECIAL PRESCRIPTIONS
FOR THE SEISMIC ZONES (2 FEBRUARY 1974)
14. UNI EN 1090: EXECUTION OF STEEL AND ALUMINUM STRUCTURES
15. UNI EN 206: CONCRETE. SPECIFICATION, PERFORMANCE, PRODUCTION AND
COMPLIANCE
16. UNI 11104: CONCRETE. SPECIFICATION, PERFORMANCE, PRODUCTION AND
COMPLIANCE. COMPLEMENTARY INSTRUCTIONS FOR THE APPLICATION OF EN
206-1
17. UNI 8520: AGGREGATES FOR CONCRETE. COMPLEMENTARY INSTRUCTIONS
FOR THE APPLICATION OF EN 1262
18. UNI 7122: TEST ON FRESH CONCRETE. DETERMINATION OF THE AMOUNT OF
EXUDED MIXING WATER
19. EN 10080: STEEL FOR THE REINFORCEMENT OF CONCRETE
20. UNI EN 13670: EXECUTION OF CONCRETE STRUCTURES – GENERAL
REQUIREMENTS
21. CNR-DT 207/2008: INSTRUCTIONS FOR EVALUATING WIND ACTIONS AND
EFFECTS ON BUILDINGS
DESIGN LOADS ARE IN ACCORDANCE WITH UFC 3-310-01, UFC 3-310-04, ASCE7,
IBC 2018, ITALIAN LAW 1086(5/11/71), LAW 64(2/02/74), DM (17/01/18)
1. LIVE LOADS:
ROOF 1.00 kpa FLOOR 2.00 kpa COMMON AREAS 4.80 kpa
2. SUPERIMPOSED LOADS - PREDALLES SLABS:
CEILING AND MEP SYSTEMS 1.00 kpa LOW SLOPE ROOF FINISHES 0.10 kpa ROOF WITH TILES FINISHES 0.80 kpa
3. SUPERIMPOSED LOADS - SIM BAY ROOF:
SANDWICH PANELS 0.20 kpa INSTALLATIONS 0.50 kpa
4. WIND LOAD :
Vu ULTIMATE WIND SPEED (3 SECOND GUST) . . 41 m/s OR 148 km/h
STRUCTURAL CLASSIFICATION ENCLOSED
RISK CATEGORY . . . II
WIND EXPOSURE . . . C
INTERNAL PRESSURE COEFFICIENT GCpi=±0.18
5. WIND LOAD (ITALIAN CODE)
Vb,0 BASIC WIND SPEED . . .25 m/s BASIC VELOCITY PRESSURE, qr = 0.39 kPa
ROUGHNESS C
EXPOSURE CATEGORY: III
6. SEISMIC PARAMETERS (US CODE):
SEISMIC IMPORTANCE FACTOR 1.0
MAPPED SPECTRAL RESPONSE ACCELERATIONS
Ss 1.25g S1 0.50g
SITE CLASS C
SPECTRAL RESPONSE COEFFICIENT
SDs 1.00g SD1 0.50g
SEISMIC DESIGN CATEGORY D
STRUCTURAL SYSTEM SPECIAL REINFORCED CONCRETE SHEAR WALL
RESPONSE MODIFICATION FACTOR R=6
SYSTEM OVERSTRENGTH FACTOR Ω=2.5
DEFLECTION AMPLIFICATION FACTOR Cd=5
7.SEISMIC PARAMETERS (ITALIAN CODE):
SITE CLASS B
SERVICEABILITY LIFE Vn=50 YEARS
OCCUPANCY CLASS II
OCCUPANCY FACTOR Cu=1.0
REFERENCE LIFE 50 YEARS
SOIL ACCELERATION FACTOR SLV ag/g=0.238g
RETURN PERIOD SLV 475
8. SNOW LOAD(US CODE):
GROUND SNOW LOAD 1.68 Kpa
IMPORTANCE FACTOR 1.0
9. SNOW LOAD (ITALIAN CODE):
GROUND SNOW LOAD 1.50 Kpa
EXPOSURE COEFFICIENT 1.
CODES DESIGN LOADS
1. CONCRETE TO BE IN ACCORDANCE WITH ACI 318-19/318R-19 "BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY". D.M.,
CONSTRUCTION CODE (17 JANUARY 2018) "NORME TECNICHE PER LE
COSTRUZIONI"
2. ALL REINFORCEMENT SHALL BE SECURELY HELD IN PLACE WITH STANDARD
ACCESSORIES WHILE PLACING CONCRETE. IF REQUIRED, ADDITIONAL BARS
OR STIRRUPS SHALL BE PROVIDED BY CONTRACTOR TO FURNISH SUPPORT
FOR ALL BARS
3. CONCRETING SHOULD BE CARRIED ON AT SUCH A RATE THAT THE
CONCRETE IS AT ALL TIMES PLASTIC
4. PARTIALLY HARDENED CONCRETE, CONTAMINATED CONCRETE,
RE-TEMPERED CONCRETE, AND CONCRETE THAT HAS BEEN RE-MIXED AFTER
IT HAS TAKEN ITS INITIAL SET ARE NOT TO BE USED IN NEW CONCRETE
PLACEMENT
5. ALL DEFORMED REINFORCING STEEL SHALL BE CLEAN AND FREE OF MUD,
OIL, RUST, AND OTHER COATINGS THAT WOULD IMPAIR PROPER BOND TO
CONCRETE. ALL REINFORCING STEEL SHALL BE CONFORMING TO ITALIAN
PRESCRIPTIONS WITH REGARDS STEEL TYPE B450C (DM 17/01/ 18) HAVING
YIELD STRENGTH OF 450 MPa
6. DETAIL ALL REINFORCEMENT IN ACCORDANCE WITH ACI 315/ NTC 2018
7. SPLICES IN ALL REINFORCING SHALL BE CLASS B AS CALCULATED PER ACI
318/NTC 2018 AND AS SHOWN ON THESE DWGS, WHICHEVER IS GREATER;
REFER TO TABLE 1 ON S-002 FOR SPLICE LENGTHS
8. REBAR SHALL BE CONTINUOUS, OR PROPERLY OVERLAPPED, AROUND ALL
CORNERS AND INTERSECTIONS OF WALLS, BEAMS, AND FOOTINGS
9. CHAMFER 20mm ALL EDGES OF EXPOSED CONCRETE
CONCRETE
1. ACI 318-19 REQUISITI DEL CODICE EDILIZIO PER IL CALCESTRUZZO ARMATO
2. UFC 1-200-01 REQUISITI GENERALI PER GLI EDIFICI, MOD. 1, (1 OTTOBRE
2020)
3. FC 1-300-09N PROCEDURE DI PROGETTAZIONE DEL CORPO DELLA MARINA,
MOD. 6, (9 LUGLIO 2021)
4. UFC 3-301-01 INGEGNERIA STRUTTURALE, (1 OTTOBRE 2019)
5. UFC 4-010-01 DOD STANDARD MINIMI ANTITERRORISMO PER GLI EDIFICI,
MOD. 1, ( 19 AGOSTO 2020)
6. ASCE 7-16 CARICHI MINIMI DI PROGETTO PER EDIFICI E ALTRE STRUTTURE
7. ISTITUTO AMERICANO PER LE COSTRUZIONI IN ACCIAIO (AISC) SPECIFICA
PER LA PROGETTAZIONE, LA FABBRICAZIONE E MONTAGGIO DELLE
STRUTTURE IN ACCIAIO PER GLI EDIFICI, QUINDICESIMA EDIZIONE
8. AWS CODICE DI SALDATURA STRUTTURALE (EDIZIONE 2015)
9. ACI 350/350R-06 NORMATIVA PER I REQUISITI DI INGEGNERIA AMBIENTALE
DELLE STRUTTURE IN CALCESTRUZZO
10. D.M., CODICE DI COSTRUZIONE (17 GENNAIO 2018)
11. CIRCOLARE DEL 21 GENNAIO 2019 N. 7. ISTRUZIONI PER L'APPLICAZIONE
DELL'AGGIORNAMENTO DELLE NORME TECNICHE PER LE COSTRUZIONI DI CUI
AL DECRETO MINISTERIALE 17 GENNAIO 2018
12. LEGGE N. 1086, NORME RELATIVE ALLE STRUTTURE IN CALCESTRUZZO
ARMATO NORMALE E PRECOMPRESSO E ALLE STRUTTURE IN ACCIAIO (5
NOVEMBRE 1971)
13. LEGGE N. 64, DISPOSIZIONI PER LE STRUTTURE, CON PRESCRIZIONI
SPECIALI PER LE ZONE SISMICHE (2 FEBBRAIO 1974)
14. UNI EN 1090: ESECUZIONE DI STRUTTURE IN ACCIAIO E ALLUMINIO
15. UNI EN 206: CALCESTRUZZO. SPECIFICHE, PRESTAZIONI, PRODUZIONE E
CONFORMITÀ
16. UNI 11104: CALCESTRUZZO. SPECIFICHE, PRESTAZIONI, PRODUZIONE E
CONFORMITÀ. ISTRUZIONI COMPLEMENTARI PER L'APPLICAZIONE DELLA EN
206-1
17. UNI 8520: AGGREGATI PER CALCESTRUZZO. ISTRUZIONI COMPLEMENTARI
PER L'APPLICAZIONE DELLA EN 1262
18. UNI 7122: TEST SUL CALCESTRUZZO FRESCO. DETERMINAZIONE DELLA
QUANTITÀ DI ACQUA D'IMPASTO TRASUDATA
19. EN 10080: ACCIAIO PER L'ARMATURA DEL CALCESTRUZZO
20. UNI EN 13670: ESECUZIONE DI STRUTTURE DI CALCESTRUZZO - REQUISITI
GENERALI
21. CNR-DT 207/2008: ISTRUZIONI PER LA VALUTAZIONE DELLE AZIONI DEL
VENTO E DEGLI EFFETTI SUGLI EDIFICI
NORMATIVE
CARICHI DI PROGETTO SONO CONFORMI A UFC 3-310-01, UFC 3-310-04, ASCE7,
IBC 2018, LEGGE 1086(5/11/71), LEGGE 64(2/02/74), DM (17/01/18)
1. CARICHI VARIABILI:
TETTO 1.00 kPa PAVIMENTO 2.00 kPa AREE COMUNI 4.80 kPa
2. CARICHI PERMANENTI - COPERTURE PREDALLES:
CONTROSOFFITTO E IMPIANTI 1.00 kPa TETTO CON PENDENZA LIEVE 0.10 kPa TETTO CON TEGOLE 0.80 kPa
3. CARICHI PERMANENTI - COPERTURA SIM BAY:
PANNELLI SANDWICH 0.20 kpa INSTALLAZIONI 0.50 kpa
4. CARICO DEL VENTO:
VELOCITÀ MASSIMA DEL VENTO (RAFFICA DI 3 SECONDI) . 41 m/s O 148 km/h
CLASSIFICAZIONE STRUTTURALE: CHIUSO
CATEGORIA DI RISCHIO . . . II
ESPOSIZIONE AL VENTO . . . C
COEFFICIENTE DI PRESSIONE INTERNA GCpi=±0,18
5. CARICO DA VENTO (NORMATIVA ITALIANA)
Vb,0 VELOCITÀ DI RIFERIMENTO DEL VENTO . .25 m/s PRESSIONE DI VELOCITÀ DI RIFERIMENTO, qb = 0,39 kPa
RUGOSITA' C
CATEGORIA DI ESPOSIZIONE: IV
6. PARAMETRI SISMICI (NORMATIVA US):
FATTORE DI IMPORTANZA SISMICA 1.0
PARAMETRI DELLE ACCELERAZIONI SPETTRALI MAPPATE
Ss 1.25g S1 0.50g
CATEGORIA DI SOTTOSUOLO C
COEFFICIENTE DI RISPOSTA SPETTRALE
SDs 1.00g SD1 0.50g
CATEGORIA DI PROGETTAZIONE SISMICA D
SISTEMA STRUTTURALE: PARETI SPECIALI A TAGLIO IN CALCESTRUZZO
ARMATO
FATTORE DI COMPORTAMENTO R=6
FATTORE DI SOVRARESISTENZA Ω=2.5
FATTORE DI AMPLIFICAZIONE DELLA DEFLESSIONE Cd=5
7. PARAMETRI SISMICI (NORMATIVA ITALIANA):
CATEGORIA DI SOTTOSUOLO B
VITA NOMINALE Vn=50 ANNI
CLASSE D'USO II
COEFFICIENTE D'USO Cu=1,0
VITA DI RIFERIMENTO 50 ANNI
ACCELERAZIONE AL SUOLO SLV ag/g=0.238g
PERIODO DI RITORNO SLV 475
8. CARICO DA NEVE (NORMATIVA US):
CARICO DA NEVE AL SUOLO 1.68 kPa
FATTORE DI IMPORTANZA 1.0
9. CARICO DA NEVE (NORMATIVA ITALIANA):
CARICO DA NEVE AL SUOLO 1.50 kPa
COEFFICIENTE DI ESPOSIZIONE 1.0
CARICHI DI PROGETTO
1. IL CALCESTRUZZO DEVE ESSERE CONFORME ALL'ACI 318-19/318R-19
"BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND
COMMENTARY". D.M., CODICE DELLE COSTRUZIONI (17 GENNAIO 2018) "NORME
TECNICHE PER LE COSTRUZIONI".
2. TUTTE LE ARMATURE DEVONO ESSERE SALDAMENTE TENUTE IN POSIZIONE
CON ACCESSORI STANDARD DURANTE LA POSA DEL CALCESTRUZZO. SE
NECESSARIO, BARRE O STAFFE AGGIUNTIVE SARANNO FORNITE
DALL'APPALTATORE PER FORNIRE SUPPORTO A TUTTE LE BARRE.
3. IL GETTO DEVE ESSERE EFFETTUATO A UN RITMO TALE CHE IL
CALCESTRUZZO SIA SEMPRE PLASTICO.
4. IL CALCESTRUZZO PARZIALMENTE INDURITO, IL CALCESTRUZZO
CONTAMINATO, IL CALCESTRUZZO RINVENUTO E IL CALCESTRUZZO CHE È
STATO RIMESCOLATO DOPO LA SUA PRESA INIZIALE NON DEVONO ESSERE
UTILIZZATI PER LA POSA DI NUOVO CALCESTRUZZO.
5. TUTTE LE ARMATURE PIEGATE DOVRANNO ESSERE PULITE E PRIVE DI
FANGO, OLIO, RUGGINE E ALTRI RIVESTIMENTI CHE POSSANO
COMPROMETTERE LA CORRETTA ADESIONE AL CALCESTRUZZO. TUTTO
L'ACCIAIO D'ARMATURA DEVE ESSERE CONFORME ALLE PRESCRIZIONI
ITALIANE PER QUANTO RIGUARDA L'ACCIAIO TIPO B450C (DM 17/01/18) CHE HA
UNA RESISTENZA ALLO SNERVAMENTO DI 450 MPa.
6. DETTAGLIARE TUTTE LE ARMATURE IN CONFORMITÀ CON ACI 315/ NTC 2018.
7. LE GIUNZIONI IN TUTTO IL RINFORZO DEVONO ESSERE DI CLASSE B COME
CALCOLATO PER ACI 318/NTC 2018 E COME MOSTRATO SU QUESTI DISEGNI,
QUALUNQUE SIA IL MAGGIORE; FARE RIFERIMENTO ALLA TABELLA 1 SU S-002
PER LE LUNGHEZZE DEI GIUNTI.
8. L'ARMATURA DEVE ESSERE CONTINUA INTORNO A TUTTI GLI ANGOLI E LE
INTERSEZIONI DI MURI, TRAVI E PIEDRITTI.
9. SMUSSARE 20mm TUTTI I BORDI DEL CALCESTRUZZO ESPOSTO.
CALCESTRUZZO
1. STRUCTURAL STEEL WORK IS TO BE DESIGNED AND CONSTRUCTED IN
ACCORDANCE WITH AISC 360, NTC 2018 AND EC3.
2. STRUCTURAL STEEL, UNLESS NOTED OTHERWISE, IS TO BE NEW STEEL
CONFORMING TO THE FOLLOWING MATERIAL REQUIREMENTS:
HE, ANGLES AND PLASTES S275 UNI-EN 10025
TUBING S275 UNI-EN 10210 AND UNI-EN
10219
3. BOLTS SHALL BE AS INDICATED IN THE DETAILS, CLASS 8.8, UNI EN ISO 898-1,
WITH MATCHING WASHERS AND HEAVY HEX NUTS, CLASS 8, UNLESS
OTHERWISE INDICATED.
4. WELDING ELECTRODES SHALL CONFORM TO UNI EN ISO 2560, AND FILLER
METAL SHALL HAVE A MINIMUM YIELD STRENGTH OF 480 MPa, UNLESS
OTHERWISE NOTED.
5. WELDS INDICATED "CJP" SHALL BE COMPLETE JOINT PENETRATION GROOVE
WELDS. FABRICATOR SHALL PRODUCE COMPLETE JOINT PENETRATION
GROOVE WELDS WHICH CONFORM TO TECHNICAL SPECIFICATION AND ALL
RELEVANT CODES REQUIREMENTS APPLICABLE TO THE SPECIFIC CONDITION
SHOWN.
6. WHERE THE WORK OF OTHER TRADES REQUIRES CUTS, HOLES, ETC., IN
STRUCTURAL STEEL MEMBERS, THEY SHALL BE MADE IN THE SHOP AND SHALL
BE SHOWN ON THE SHOP DRAWINGS. MAKING HOLES OR CUTS IN
STRUCTURAL STEEL MEMBERS IN THE FIELD WILL NOT BE PERMITTED
WITHOUT SPECIFIC APPROVAL OF THE OWNER'S REPRESENTATIVE.
7. ALL DISCREPANCIES FOUND ARE TO BE REPORTED TO THE CONTRACTING
OFFICER'S REPRESENTATIVE PRIOR TO PREPARATION OF SHOP DRAWINGS.
SHOP DRAWINGS ARE TO INCLUDE ALL FIELD MEASUREMENTS AND
CONDITIONS OF THE ELEMENTS SUPPORTING THE STEEL TRUSSES.
8. TO PROTECT THE STEEL TRUSSES FROM THE FIRE, THE FOLLOWING
SOLUTION IS REQUIRED:
8.1. SURFACE CLEANING AND FINISHING WITH SANDPAPER AT DEGREE SA2.5
TO REMOVE TRACES OF GREASE, CALAMINE OR OTHER INCOHERENT
MATERIAL;
8.2. TREATMENT WITH EPOXY POLYAMIDE PRIMER, MINIMUM THICKNESS OF
50/70 MICRON;
8.3. VARNISHING OF STEEL ELEMENTS WITH FIRE-PROOF PAINT; APPLIED IN
THE THICKNESS NECESSARY TO GUARANTEE THE REQUIRED FIRE
RESISTANCE CLASS, SPECIFIED IN THE FIRE PROTECTION DRAWINGS;
8.4. FINISHING WITH PURE RUBBER CHLORINATED PAINT FOR A MINIMUM
THICKNESS OF 40 MICRON.
STEEL
1. LE OPERE IN ACCIAIO STRUTTURALE DEVONO ESSERE PROGETTATE E
COSTRUITE IN CONFORMITÀ DELLE NORME AISC 360, DM17/01/2018 ED EC3.
2. SE NON DIVERSAMENTE SPECIFICATO, L'ACCIAIO STRUTTURALE DEVE
ESSERE ACCIAIO NUOVO CONFORME AI SEGUENTI REQUISITI:
HE, ANGOLARI E PIASTRE S275 UNI-EN 10025
TUBOLARI S275 UNI-EN 10210 AND UNI-EN
10219
3. SE NON DIVERSAMENTE SPECIFICATO, I BULLONI DEVONO ESSERE CLASSE
8.8, UNI EN ISO 898-1, CON RONDELLE CORRISPONDENTI E DADI ESAGONALI
PESANTI, CLASSE 8.
4. GLI ELETTRODI DI SALDATURA DEVONO ESSERE CONFORMI ALLA NORMA UNI
EN ISO 2560 E IL METALLO DI RIEMPIMENTO DEVE AVERE UNA RESISTENZA
MINIMA ALLO SNERVAMENTO DI 480 MPA. SE NON SPECIFICATAMENTE
INDICATO.
5. LE SALDATURE INDICATE COME "CJP" SONO SALDATURE A COMPLETO
RIPRISTINO DEL GIUNTO. IL FABBRICANTE DEVE PRODURRE SALDATURE A
COMPLETO RIPRISTINO DEL GIUNTO CONFORMI ALLE SPECIFICHE TECNICHE E
A TUTTI I REQUISITI NORMATIVI APPLICABILI ALLA CONDIZIONE SPECIFICA
INDICATA.
6. QUALORA IL LAVORO DI ALTRE OPERAZIONI RICHIEDE TAGLI, FORI, ECC.
NEGLI ELEMENTI STRUTTURALI IN ACCIAIO, QUESTI DEVONO ESSERE ESEGUITI
IN OFFICINA E DEVONO ESSERE INDICATI SUI DISEGNI D'OFFICINA. NON È
CONSENTITO PRATICARE FORI O TAGLI NEGLI ELEMENTI STRUTTURALI IN
ACCIAIO IN CANTIERE SENZA L'APPROVAZIONE ESPRESSA DEL
RAPPRESENTANTE DEL COMMITTENTE.
7. TUTTE LE DISCREPANZE RISCONTRATE DEVONO ESSERE SEGNALATE AL
RAPPRESENTANTE DEL COMMITTENTE PRIMA DELLA PREPARAZIONE DEI
DISEGNI D'OFFICINA. I DISEGNI D'OFFICINA DEVONO COMPRENDERE TUTTE LE
MISURE E LE CONDIZIONI DELL'OPERA A CUI VERRANNO COLLEGATI GLI
ELEMENTI IN ACCIAIO.
8. PER PROTEGGERE LE TRAVATURE RETICOLARI IN ACCIAIO DAL FUOCO, LA
SOLUZIONE SEGUENTE E' STATA PREVISTA:
8.1. PULIRE LA SUPERFICIE CON SABBIAURA SA2.5 PER RIMUOVERE TRACCE
DI GRASSO, CALAMINA O ALTRO MATERIALE.
8.2. TRATTAMENTO CON PRIMER EPOSSIDICO POLIAMMIDICO, SPESSORE
MINIMO 50/70 MICRON;
8.3. VERNIFICATURA DEGLI ELEMENTI IN ACCIAIO CON VERNICE
INTUMESCENTE; APPLICATA CON UNO SPESSORE ADEGUATO A GARANTIRE
LA CLASSE DI RESISTENZA A FUOCO RICHIESTA, SPECIFICATA NEGLI
ELEBORATI DI PROGETTO ANTINCENDIO;
8.4. FINITURA CON VERNICE IN GOMMA CLORURATA CON UNO SPESSORE
MINIMO DI 40 MICRON.
ACCIAIO
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
1684614
11/07/22
Richard Tyler, PE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
100 AIRSIDE DRIVE
MOON TOWNSHIP, PA 15108
AV
IA
N O
A
IR
B
AS
E
AV
IA
N
O , I
TA
LY
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
FI
LE
N
AM
E:
PL
OT
TE
D:
LMM / BTN
FIRE PROTECTION DPS
F2
AD
AL
C O
M
BA
T R
ES
C
U E
H
EL
IC
O
PT
ER
SI
M
U
LA
TO
R
F
AC
IL
IT
Y (P
2)
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N S
TR
U
C
TI
O N
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
DRAWFORM REVISION: 12 APRIL 2018
ISSUED FOR CONSTRUCTION – 10 MAR 2023
AS NOTED
BI
M
P
Si m ul at or
/B
LD
G P
2-
4-
S.
rv t 3/
7/
1:
:1
AM
ST
R
U C
TU
R
AL
G
EN
ER
AL
N
O
TE
S
SITMMIDB
S-001
NO
TE
G
EN
ER
AL
I S
TR
U
TT
U R
AL
I
14125426
JTW
Kurt.Liebmann Snapshot
BEFORE THE EXECUTION OF THE WORK, THE CONTRACTOR HAS THE OBLIGATION TO CHECK
ALL THE QUOTAS AND MEASURES INDICATED IN THIS DRAWING.
ANY DIFFORMITIES MUST BE REPORTED TO THE DIRECTOR OF WORK.
C12/15 (Rck 15 MPa) C30/37 (Rck 37 MPa)
B450CSTEEL FOR REINFORCED CONCRETE AND WELDED MESH:
STEEL
LEAN CONCRETE
CONCRETE FOR FOUNDATION AND ELEVATION STRUCTURES
CONCRETE
CHARACTERISTIC YIELDING STRESS
CHARACTERISTIC TENSILE STRESS
MINIMUM PERCENTAGE STRETCH
BREAKING/YIELDING
450 MPa 540 MPa gtA 7.5 % tkf1.15 f yk/ 1.35
- GROUND SLAB
- WALLS AND SLABS
- BEAMS (TO STIRRUPS)
- COLUMNS AND PIERS
L s s s s
GENERAL NOTES
CONCRETE COVER
CONVENTIONS
THE INDICATED LENGTH OF THE BARS IS "OVERALL" (STANDARDS ISO/DIN 4066)
1) FOR FOUNDATIONS, PROVIDE A CLEANING POURING (LEAN CONCRETE) OF AT LEAST 10 cm, IF NOT OTHERWISE SPECIFIED.
2) OVERLAP THE REINFORCMENT BARS FOR AT LEAST 40 DIAMETERS, IF NOT OTHERWISE SPECIFIED.
3) THE REINFORCEMENT BARS MUST BE BENT TO THE ENDS AS INDICATED IN THE REFERENCE DRAWINGS.
4) THE REINFORCEMENT BARS WITH 90 ° BRACKETS MUST BE ATTACHED TO A
TRANSVERSAL BAR PREPARED ION PURPOSE OR BELONGING TO A CROSS BEAM
5) BEND CLOSING BRACKETS AT 135°
6) ALL THE STRCTURAL MATERIAL MUST HAVE CE MARKING (EUROPEAN COMMUNITY)
Mi n.1
0∅
5°
10∅ ∅
NOMINAL ACCEPTANCE ON SITE
f yk f tk min. 425 MPa max. 572 MPa
6.0 % tk1.13 yk/ 1.37f f
COLUMNS-BEAMS SLAB-WALLS
RESISTANCE CLASS EXPOSURE CLASS
X0
XC1-XC3
SLUMP W/C
S4 S4
Smin = 75mm Smin = 40mm Smin = 40mm Smin = 50mm
0,55
STRUCTURAL STEEL: S275
CHARACTERISTIC YIELD STRENGTH
CHARACTERISTIC TENSILE STRENGTH
BOLTS CLASS 8.8 - NUTS CLASS 8
275 MPa 430 MPa f yk f tk
PRIMA DELL'ESECUZIONE DEI LAVORI L'APPALTATORE HA L'OBBLIGO DI VERIFICARE CHE TUTTE LE
QUOTE E LE MISURE RIPORTATE SU QUESTO DISEGNO.
OGNI DIFFORMITÀ VA RIPORTATA AL DIRETTORE DEI LAVORI.
C12/15 (Rck 15 MPa) C30/37 (Rck 37 MPa)
B450CACCIAIO PER CLS RINFORZATO CON MAGLIA ELETTROSALDATA:
ACCIAIO
CALCESTRUZZO MAGRO
CALCESTRUZZO PER FONDAZIONE E STRUTTURE IN ELEVAZIONE
CALCESTRUZZO
TENSIONE DI SNERVAMENTO CARATTERISTICA
TENSIONE DI ROTTURA CARATTERISTICA
PERCENTUALE MINIMA DI ALLUNGAMENTO
ROTTURA / SNERVAMENTO
450 MPa 540 MPa gtA 7.5 % tkf1.15 f yk/ 1.35
- SOLAIO SU TERRA
- MURI E SOLAI
- TRAVI
- COLONNE E PILASTRI
L s s s s
NOTE GENERALI
COPRIFERRO
CONVENZIONI
LA LUNGHEZZA INDICATA SULLE BARRE È "TUTTO FUORI" (STANDARDS ISO/DIN 4066)
1) PER FONDAZIONI, PREVEDERE UNA GETTO (MAGRONE) DI ALMENO 10cm. SE NON DIVERSAMENTE SPECIFICATO
2) SOVRAPPORE LE BARRE DI RINFORZO PER ALMENO 40 DIAMETRI, SE NON DIVERSAMENTE SPECIFICATO
3) LE BARRE DI RINFORZO DEVONO ESSERE PIEGATE ALLE ESTREMITÀ COME INDICATO SUI DISEGNI DI RIFERIMENTO
4) LE BARRE DI RINFORZO CON PIEGHE A 90° DEVONO ESSERE ATTACCATE AD
UNA BARRA TRASVERSALE APPOSITA O APPARTENTENTE AD UNA TRAVE INCROCIATA
5) CHIUSURA SUPPORTI A 135°
6) TUTTI I MATERIALI STRUTTURALI DEVONO AVERE IL MARCHIO CE (EUROPEAN COMMUNITY)
Mi n.1
0∅
5°
10∅ ∅
NOMINALE ACCETTAZIONE IN CANTIERE
f yk f tk min. 425 MPa max. 572 MPa
6.0 % tk1.13 yk/ 1.37f f
COLUMNS-BEAMS SLAB-WALLS
CLASSE DI RESISTENZA CLASSE DI ESPOSIZIONE
X0
XC1-XC3
SLUMP W/C
S4 S4
Smin = 75mm Smin = 40mm Smin = 40mm Smin = 50mm
0,55
ACCIAIO STRUTTURALE: S275
BULLONI CLASSE 8.8 - DADI CLASSE 8
FORZA DI SNERVAMENTO CARATTERISTICA
FORZA DI ROTTURA CARATTERISTICA
275 MPa 430 MPa f yk f tk
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
1684614
11/07/22
Richard Tyler, PE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
100 AIRSIDE DRIVE
MOON TOWNSHIP, PA 15108
AV
IA
N O
A
IR
B
AS
E
AV
IA
N
O , I
TA
LY
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
FI
LE
N
AM
E:
PL
OT
TE
D:
LMM / BTN
FIRE PROTECTION DPS
F2
AD
AL
C O
M
BA
T R
ES
C
U E
H
EL
IC
O
PT
ER
SI
M
U
LA
TO
R
F
AC
IL
IT
Y (P
2)
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N S
TR
U
C
TI
O N
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
DRAWFORM REVISION: 12 APRIL 2018
ISSUED FOR CONSTRUCTION – 10 MAR 2023
AS NOTED
BI
M
P
Si m ul at or
/B
LD
G P
2-
4-
S.
rv t 3/
7/
1:
:1
AM
ST
R
U C
TU
R
AL
G
EN
ER
AL
N
O
TE
S
SITMMIDB
S-002
NO
TE
G
EN
ER
AL
I S
TR
U
TT
U R
AL
I
14125427
JTW
MINIMUM LAP SPLICE AND ANCHORAGE DIMENSION TABLE
BAR DIAMETER (mm) 8 10 12 16 20 32 40
DEVELOPMENT LENGTH 320 400 470 630 790 1550 1940
LAP LENGTH 450 560 670 890 1120 1780 2230
NOTES FOR TABLE #1
1. FOR BUNDLED BARS MULTIPLY THE TABLE VALUES BY: 1.2 (3 BAR BUNDLE),
1.33 (4 BAR BUNDLE);
2. (MC) DENOTES MECHANICAL COUPLER DEVELOPING 125% OF THE BAR
YIELD STRENGTH. NO OTHER SPLICE WILL BE ACCEPTED;
3. WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP DIMENSION OF
THE SMALLER BAR OR THE ANCHORAGE DIMENSIONS OF THE LARGER BAR.
USE WHICHEVER DIMENSION IS LARGER;
4. MECHANICAL SPLICES MAY BE PROVIDED AS A CONTRACTOR OPTION;
PROVIDED THE MECHANICAL COUPLERS ARE CAPABLE OF DEVLOPING 125%
OF THE BAR YIELD STRENGTH.
TABLE #1
1. GENERAL NOTES AND TYPICAL DETAILS APPLY TO ALL STRUCTURAL
FEATURES UNLESS OTHERWISE SHOWN OR NOTED. IF CERTAIN FEATURES
ARE NOT FULLY SHOWN OR CALLED FOR ON THE DRAWINGS OR
SPECIFICATIONS, THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER
AS FOR SIMILAR CONDITIONS
2. ANCHORS ARE TO BE INSTALLED WITHIN A TOLERANCE OF 6mm OF
SPECIFIED LOCATION
3. THE STRUCTURES ARE DESIGNED TO BE SELF-SUPPORTING AND STABLE
AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND
TO ENSURE THE SAFETY OF WORKERS, THE BUILDING AND ITS COMPONENT
PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER
SHORING,TEMPORARY BRACING, ETC. THAT MAY BE NECESSARY AS WELL AS
FULL COMPLIANCE WITH ALL APPLICABLE OSHA REGULATIONS. OBSERVATION
VISITS TO THE SITE BY AECOM PERSONAL SHALL NOT INCLUDE INSPECTION
FOR THESE ITEM
4. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO ENSURE ALL WORK IS
PERFORMED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
5. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF OPENING AND
HEIGHTS OF ALL WALLS NOT SHOWN OR OTHERWISE NOTED ON THE
STRUCTURAL DRAWINGS
6. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZE AND
LOCATION OF ALL FLOOR AND ROOF OPENINGS NOT SHOWN OR OTHERWISE
NOTED ON THE STRUCTURAL DRAWINGS
7. DIMENSIONS SHALL NOT BE SCALED
8. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS
RELATIVE TO SAME. WHERE THERE ARE CONFLICTS BETWEEN ACTUAL FIELD
CONDITIONS AND/OR DATA PRESENTED ON THESE DRAWINGS, SUCH
CONDITIONS SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT &
ENGINEER
IMMEDIATELY, AND NECESSARY ADJUSTMENTS MADE PER THEIR
INSTRUCTIONS.
9. COORDINATE BONDING OF FOUNDATION REBAR TO ELECTRICAL GROUND
WITH ELECTRICAL CONTRACTOR
10. SPECIFICATIONS, CODES, AND STANDARDS NOTED IN THESE CONTRACT
DOCUMENTS SHALL BE OF THE LATEST EDITION APPROVED BY THE
APPROPRIATE REGULATORY AGENCIES
11. CONTRACTOR TO COORDINATE CONSTRUCTION DETAILS WITH THE
MANUFACTURER BEFORE POURING THE STRUCTURAL ELEMENTS
SUPPORTING THE
OVERHEAD CRANE
12. CONTRACTOR TO COORDINATE THE POSITION OF THE TRENCHES BEFORE
POURING THE SLAB-ON-GRADE OF THE SIMULATOR BAY AND TECH ROOMS
GENERAL
1. THE EXCAVATION OF ALL DEBRIS-LADEN MATERIALS AND SUBSEQUENT
REPLACEMENT WITH COMPACTED FILL LOCATED BENEATH THE ENTIRE
STRUCTURE FOOTPRINT PLUS A 1.5M MARGIN OUTSIDE THE PERIMETER
FOUNDATION IN STRICT ACCORDANCE WITH ALL OF THE RECOMMENDATIONS
BY GEOTECHNICAL ENGINEER FOR THIS PROJECT.
2.THE DEGREE OF COMPACTION OF ANY GRANULAR MATERIALS USED TO
REACH THE FINAL PROJECT LEVEL MUST BE VERIFIED BY TESTS ON A
CIRCULAR PLATE WITH A DIAMETER OF 30 CM THROUGH A DOUBLE LOADING
AND UNLOADING CYCLE ACCORDING TO THE RECOMMENDATIONS OF CNR
146/1992
3. ALL FOUNDATIONS SHALL BE CENTERED UNDER COLUMN OR WALL
CENTERLINES UNLESS SHOWN OR NOTED OTHERWISE
4. REPORT ANY UNUSUAL BELOW GRADE CONDITIONS ENCOUNTERED TO THE
STRUCTURAL ENGINEER
5. A GEOTECHNICAL ENGINEER SHALL OBSERVE THE OPEN EXCAVATION TO
DETERMINE THAT THE SOIL TYPE AND CONDITIONS ARE CONSISTENT WITH
DESIGN CRITERIA OF THE SOIL REPORT. IF THE SOIL PROPERTIES ARE FOUND
TO BE DIFFERENT FROM THIS CRITERIA THE OW’SN ERREPRESENTATIVE SHALL
BE
PROMPTLY NOTIFIED SO THAT THE FOUNDATION DESIGN MAY BE REVIEWED
6. QUALITY ASSURANCE COMPACTION DENSITY UNDER FOOTINGS AND SLABS
SHALL BE A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED
BY ASTM D-1557 (MODIFIED PROCTOR) THROUGHOUT EACH LIFT, AS INDICATED
IN THE SPECS.
7. BELOW THE SLAB ON GRADE SUPPORTED OVER WELL COMPACTED FILL,
A DEFORMATION MODULUS OF 80MPA SHALL BE REACHED AFTER COMPACTION
OF THE SOIL; PLATE LOAD TESTS CARRIED OUT BY AN AUTHORIZED
LABORATORY ARE REQUIRED
8. REFER TO SHEET B-001 FOR BEARING CAPACITIES LIMIT FOR EACH TYPE OF
FOUNDATION.
FOUNDATION
1. LE NOTE GENERALI E I DETTAGLI TIPICI SI APPLICANO A TUTTE LE
CARATTERISTICHE STRUTTURALI A MENO CHE NON SIA MOSTRATO O
ANNOTATO DIVERSAMENTE. SE ALCUNE CARATTERISTICHE NON SONO
COMPLETAMENTE MOSTRATE O RICHIESTE NEI DISEGNI O NELLE SPECIFICHE,
LA LORO COSTRUZIONE DEVE SEGUIRE LO STESSO PRINCIPIO SEGUITO IN
CONDIZIONI SIMILI
2. GLI ANCORAGGI DEVONO ESSERE INSTALLATI ENTRO UNA TOLLERANZA DI
6mm DALLA POSIZIONE SPECIFICATA
3. QUESTE STRUTTURE SONO PROGETTATE PER ESSERE AUTOPORTANTI E
STABILI DOPO CHE LA COSTRUZIONE DELL'EDIFICIO È ULTIMATA. È
RESPONSABILITÀ DELL'APPALTATORE DETERMINARE LA PROCEDURA E LA
SEQUENZA DI MONTAGGIO E GARANTIRE LA SICUREZZA DEI LAVORATORI,
DELL'EDIFICIO E DELLE SUE PARTI COMPONENTI DURANTE IL MONTAGGIO.
QUESTO INCLUDE L'AGGIUNTA DI QUALSIASI PUNTELLAMENTO, RINFORZO
TEMPORANEO, ECC. CHE POSSONO ESSERE NECESSARI, COSÌ COME IL PIENO
RISPETTO DI TUTTI I REGOLAMENTI OSHA APPLICABILI. LE VISITE DI
OSSERVAZIONE AL SITO DA PARTE DEL PERSONALE AECOM NON INCLUDONO
L'ISPEZIONE DI QUESTI ELEMENTI.
4. È ESCLUSIVA RESPONSABILITÀ DELL'APPALTATORE ASSICURARE CHE TUTTO
IL LAVORO SIA ESEGUITO IN CONFORMITÀ AI DOCUMENTI DEL CONTRATTO
5. FARE RIFERIMENTO AI DISEGNI ARCHITETTONICI PER LE POSIZIONI DELLE
APERTURE E LE ALTEZZE DI TUTTE LE PARETI NON MOSTRATE O ALTRIMENTI
ANNOTATE SUI DISEGNI STRUTTURALI
6. FARE RIFERIMENTO AI DISEGNI ARCHITETTONICI E MECCANICI PER LE
DIMENSIONI E LA POSIZIONE DI TUTTE LE APERTURE DEL PAVIMENTO E DEL
TETTO NON MOSTRATE O ALTRIMENTI ANNOTATE SUI DISEGNI STRUTTURALI
7. LE DIMENSIONI NON DEVONO ESSERE SCALATE
8. L'APPALTATORE DEVE VERIFICARE TUTTE LE CONDIZIONI DEL CAMPO E LE
DIMENSIONI RELATIVE ALLO STESSO. DOVE CI SONO CONFLITTI TRA LE
CONDIZIONI REALI DEL CAMPO E/O I DATI PRESENTATI SU QUESTI DISEGNI,
INFORMARE L'INGEGNERE E L’ARCHITETTO IMMEDIATAMENTE, E SVILUPPARE
LE REGOLAZIONI NECESSARIE FATTE SECONDO LE SUE ISTRUZIONI
9. COORDINARE IL COLLEGAMENTO DELL'ARMATURA DI FONDAZIONE ALLA
MESSA A TERRA CON L'APPALTATORE ELETTRICO
10. LE SPECIFICHE, I CODICI E GLI STANDARD INDICATI IN QUESTI DOCUMENTI
CONTRATTUALI DEVONO ESSERE DELL'ULTIMA EDIZIONE APPROVATA
DALLEAGENZIE DI REGOLAMENTAZIONE APPROPRIATE
11. L’APPALTATORE PER I PARTICOLARI COSTRUTTIVI DOVRA’ COORDINARSI
CON IL PRODUTTORE PRIMA DELLE OPERAZIONI DI GETTO DI CALCESTRUZZO
DEGLI ELEMENTI STRUTTURALI DI SOSTEGNO DEL CARRELLO
12. L’APPALTATORE DOVRA’ DEFINIRE LA POSIZIONE DEI CUNICOLI PRIMA
DELLE OPERAZIONI DI GETTO DI CALCESTRUZZO DELLE SOLETTE DEL
SIMULATOR BAY E DELLE TECH ROOMS.
GENERALE
1. LO SCAVO DI TUTTI I MATERIALI CARICHI DI DETRITI E LA SUCCESSIVA
SOSTITUZIONE CON MATERIALE DI RIEMPIMENTO COMPATTATO SITUATO
SOTTO L'INTERA IMPRONTA DELLA STRUTTURA PIÙ UN MARGINE DI 1,5 M
ALL'ESTERNO DELLA FONDAZIONE PERIMETRALE IN STRETTA CONFORMITÀ
CON TUTTE LE RACCOMANDAZIONI DELL'INGEGNERE GEOTECNICO PER
QUESTO PROGETTO.
2. IL GRADO DI COMPATTAZIONE DEI MATERIALI GRANULARI EVENTUALMENTE
UTILIZZATI PER RAGGIUNGERE IL LIVELLO FINALE DEL PROGETTO DEVE
ESSERE VERIFICATO MEDIANTE PROVE DI CARICO SU UNA PIASTRA
CIRCOLARE DEL DIAMETRO DI 30 CM ATTRAVERSO UN DOPPIO CICLO DI
CARICO E SCARICO SECONDO LE RACCOMANDAZIONI DEL CNR 146/1992.
3. TUTTE LE FONDAZIONI DEVONO ESSERE CENTRATE SOTTO LA MEZZERIA
DELLA COLONNA O DELLA PARETE A MENO CHE NON SIA MOSTRATO O
INDICATO DIVERSAMENTE.
4. SEGNALARE ALL'INGEGNERE STRUTTURALE QUALSIASI CONDIZIONE
INSOLITA SOTTO IL LIVELLO DEL TERRENO INCONTRATA.
5. UN INGEGNERE GEOTECNICO DEVE OSSERVARE LO SCAVO APERTO PER
DETERMINARE CHE IL TIPO E LE CONDIZIONI DEL SUOLO SIANO COERENTI CON
I CRITERI DI PROGETTAZIONE DEL REPORT GEOTECNICO. SE LE PROPRIETÀ
DEL SUOLO SONO DIVERSE DA QUESTI CRITERI, IL CLIENTE DEVE ESSERE
PRONTAMENTE INFORMATO IN MODO CHE IL PROGETTO DELLA FONDAZIONE
POSSA ESSERE RIVISTO.
6. LA DENSITÀ DI COMPATTAZIONE SECONDO IL CONTROLLO QUALITA' SOTTO
LE FONDAZIONI DEVE ESSERE ALMENO IL 95% DELLA DENSITÀ SECCA MASSIMA
COME DETERMINATA DA ASTM D-1557 (PROCTOR MODIFICATO) PER OGNI
STRATO, COME INDICATO NELLE SPECIFICHE.
7. AL DI SOTTO DELLE PAVIMENTAZIONI INDUSTRIALI SU TERRENO
COMPATTATO, UN MODULO DI DEFORMAZIONE DI 80MPA DEVE ESSERE
RAGGIUNTO DOPO LA COMPATTAZIONE DEL TERRENO; SONO RICHIESTE
PROVE DI CARICO SU PIASTRA ESEGUITE DA UN LABORATORIO AUTORIZZATO.
8. FARE RIFERIMENTO ALLA TAVOLA B-001 PER I LIMITI DI CAPACITA' PORTANTE
PER OGNI TIPOLOGIA DI FONDAZIONE
FONDAZIONI
TABLELLA DELLE DIMENSIONI MINIME DI GIUNZIONE E DI ANCORAGGIO
DIAMETRO DELLA BARRA (mm) 8 10 12 16 20 32 40
LUNGHEZZA DI SVILUPPO 320 400 470 630 790 1550 1940
LUNGHEZZA DI SOVRAPPOSIZIONE 450 560 670 890 1120 1780 2230
NOTE PER LA TABELLA #1
1. PER LE BARRE IN FASCIO MOLTIPLICARE I VALORI DELLA TABELLA PER: 1.2
(FASCIO DI 3 BARRE), 1.33 (FASCIO DI 4 BARRE).
2. (MC) INDICA UN ACCOPPIAMENTO MECCANICO CHE SVILUPPA IL 125% DEL
CARICO DI SNERVAMENTO DELLA BARRA. NESSUN'ALTRA GIUNZIONE SARÀ
ACCETTATA.
3. QUANDO SI SOVRAPPONGONO DUE BARRE DI DIMENSIONI DIVERSE,
UTILIZZARE LA DIMENSIONE DI SOVRAPPOSIZIONE O LE DIMENSIONI DI
ANCORAGGIO DELLA BARRA PIÙ GRANDE.
4. GLI ANCORANTI MECCANICI POSSONO ESSERE FORNITI COME OPZIONE
DELL'APPALTATORE; A CONDIZIONE CHE GLI ANCORANTI MECCANICI SIANO IN
GRADO DI SVILUPPARE IL 125% DEL CARICO DI SNERVAMENTO DELLA BARRA.
TABELLA #1
FALL PROTECTION ANCHORS ARE TO BE DESIGNED FOR AN ULTIMATE CONCETRATED
LIVE LOAD OF 22.3kN APPLIED IN ANY DIRECTION PER OSHA 1910.140C. THE PRODUCT
SHALL ALSO BE A CERTIFICATED FALL PROTECTION SYSTEM IN ITALY.
FOR PROPOSED FALL PROTECTION LOCATIONS ON THE ROOFS SEE ARCHITECTURAL
PACKAGE.
COORDINATE THE FINAL LOCATIONS, LOADS AND FIXING OF FALL PROTECTION
ANCHORAGE BETWEEN FALL PROTECTION PROVIDER AND THE PREDALLE FABRICATOR
AND THE ROOF PANELS MANUFACTURER.
ROOF FALL PROTECTION
GLI ANCORANTI DI PROTEZIONE ANTICADUTA DEVONO ESSERE PROGETTATI PER UN
CARICO CONCENTRATO ULTIMO DI 22,3 kN APPLICATO IN QUALSIASI DIREZIONE COME
PRESCRITTO DA OSHA 1910.140C. IL PRODOTTO DEVE ESSERE ANCHE UN SISTEMA
ANTICADUTA CERTIFICATO IN ITALIA.
PER LE POSIZIONI DEI SISTEMI DI PROTEZIONE ANTICADUTA PROPOSTE SUI TETTI
VEDERE TAVOLE ARCHITETTONICHE.
COORDINARE LE UBICAZIONI FINALI, I CARICHI E IL FISSAGGIO DEGLI ANCORAGGI
ANTICADUTA CON IL FORNITORE DEL SISTEMA ANTICADUTA E IL PRODUTTORE DELLE
PREDALLE E IL FORNITORE DEI PANNELLI DI COPERTURA.
SISTEMA ANTICADUTA DAL TETTO
2'
"4a"
"2 a"
"4a"
TYP
"a"
TYP
"a"TYP
"a"
TYP
"a"
NOTE: WIDTH OF EDGE STRIP "a" = 1,80m FOR SIM BAY WIDTH OF EDGE STRIP "a" = 2,00m FOT THE LOWER BLDG
CC1. ALL COMPONENT & CLADDING MATERIALS NOT SPECIFICALLY DESIGNED
OR OTHERWISE NOTED ON THESE DWGS SHALL SAFELY RESIST THESE
MINIMUM DESIGN WIND PRESSURES FOR THE SUBJECT MEMBER'S EFFECTIVE
WIND AREA AS WELL AS THE WIND PRESSURES RESULTING FROM THE DESIGN
WIND SPEED AND APPLICABLE CODES AS INDICATED ON THE STRUCTURAL
NOTES AND SPECIFICATIONS (WHICHEVER ARE GREATER). THE EFFECTIVE
WIND AREA SHALL BE DEFINED AS THE SPAN LENGTH MULTIPLIED BY AN
EFFECTIVE WIDTH THAT NEED NOT BE LESS THAN ONE-THIRD THE SPAN
LENGTH. FOR CLADDING FASTENERS, THE EFFECTIVE WIND AREA SHALL NOT
BE GREATER THAN THE AREA THAT IS TRIBUTARY TO AN INDIVIDUAL FASTENER.
CC2. DESIGN WIND ZONES INDICATED SHALL BE LOCATED IN ACCORDANCE
WITH THE ADJACENT SCHEMATIC ROOF AND WALL ZONE LOCATION DIAGRAMS.
CC3. PLUS AND MINUS SIGNS SIGNIFY GROSS COMPONENT PRESSURES
ACTING TOWARD AND AWAY FROM BLDG SURFACES.
CC4. FOR EFFECTIVE AREAS BETWEEN THOSE LISTED, THE LOAD MAY BE
INTERPOLATED OR USE THE LOAD ASSOCIATED WITH THE LOWER AREA.
CC5. THE DESIGN WIND PRESSURE FOR C&C SHALL NOT BE LESS THAN A NET
PRESSURE OF 0.77 kN/m2, ACTING IN EITHER DIRECTION NORMAL TO THE
SURFACE.
"2a" "2a"
NOTE: WIDTH OF EDGE STRIP "a" = 1,80m FOR THE SIM BAY WIDTH OF EDGE STRIP "a" = 2,00m FOR THE LOWER BLDG
COMPONENT & CLADDING NOTES:
WALL ZONES (ISOMETRIC)
MONOSLOPE ROOF ZONES (PLAN)
"2 a"
"2 a"
CC1. TUTTI I COMPONENTI E I MATERIALI DI RIVESTIMENTO NON
SPECIFICAMENTE PROGETTATI O ALTRIMENTI ANNOTATI SU QUESTI DISEGNI
DEVONO RESISTERE IN MODO SICURO A QUESTE PRESSIONI DEL VENTO
MINIME DI PROGETTO PER L'AREA EFFETTIVA DEL VENTO DELL'ELEMENTO IN
QUESTIONE, NONCHÉ ALLE PRESSIONI DEL VENTO RISULTANTI DALLA
VELOCITÀ DEL VENTO DI PROGETTO E DAI CODICI APPLICABILI COME INDICATO
NELLE NOTE STRUTTURALI E NELLE SPECIFICHE (A SECONDA DI QUALE SIA
MAGGIORE). L'AREA EFFETTIVA DEL VENTO È DEFINITA COME LA LUNGHEZZA
DELLA CAMPATA MOLTIPLICATA PER UNA LARGHEZZA EFFETTIVA CHE NON
DEVE ESSERE INFERIORE A UN TERZO DELLA LUNGHEZZA DELLA CAMPATA.
PER GLI ELEMENTI DI FISSAGGIO DEL RIVESTIMENTO, L'AREA EFFETTIVA DEL
VENTO NON DEVE ESSERE MAGGIORE DELL'AREA CHE È TRIBUTARIA DI UN
SINGOLO ELEMENTO DI FISSAGGIO.
CC2. LE ZONE DI VENTO DI PROGETTO INDICATE DEVONO ESSERE SITUATE IN
CONFORMITÀ CON I DIAGRAMMI SCHEMATICI DI LOCALIZZAZIONE DELLE ZONE
DEL TETTO E DELLE PARETI ADIACENTI.
CC3. I SEGNI PIÙ E MENO INDICANO LE PRESSIONI LORDE DEI COMPONENTI
CHE AGISCONO VERSO E LONTANO DALLE SUPERFICI DELL'EDIFICIO.
CC4. PER LE AREE EFFICACI TRA QUELLE ELENCATE, IL CARICO PUÒ ESSERE
INTERPOLATO O SI PIO’ UTILIZZARE IL CARICO ASSOCIATO ALL'AREA
INFERIORE.
CC5. LA PRESSIONE DEL VENTO DI PROGETTAZIONE PER C&C NON DEVE
ESSERE INFERIORE A UNA PRESSIONE NETTA DI 0,77 kN/m2, AGENTE IN
ENTRAMBE LE DIREZIONI NORMALI ALLA SUPERFICIE.
NOTE SUI COMPONENTI E SUI
RIVESTIMENTI:
NOTA: LARGHEZZA DELLA STRISCIA DI BORDO "a" = 1,80m PER IL SIM BAY LARGHEZZA DELLA STRISCIA DI BORDO "a" = 2,00m PER L'EDIFICIO INFERIORE
ZONE DEL MURO (ISOMETRICHE)
NOTA: LARGHEZZA DELLA STRISCIA DI BORDO "a" = 1,80m PER LA SIM BAY LARGHEZZA DELLA STRISCIA DI BORDO "a" = 2,00m PER IL BLDG INFERIORE
ZONE DEL TETTO MONOPENDENTE
(PIANTA)
"4a"
"2 a"
"4a"
"a" "a"
"a
"a
3' 2'
2'
3'
2 2
2 3
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
1684614
11/07/22
Richard Tyler, PE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
100 AIRSIDE DRIVE
MOON TOWNSHIP, PA 15108
AV
IA
N O
A
IR
B
AS
E
AV
IA
N
O , I
TA
LY
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
FI
LE
N
AM
E:
PL
OT
TE
D:
LMM / BTN
FIRE PROTECTION DPS
F2
AD
AL
C O
M
BA
T R
ES
C
U E
H
EL
IC
O
PT
ER
SI
M
U
LA
TO
R
F
AC
IL
IT
Y (P
2)
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N S
TR
U
C
TI
O N
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
DRAWFORM REVISION: 12 APRIL 2018
ISSUED FOR CONSTRUCTION – 10 MAR 2023
AS NOTED
BI
M
P
Si m ul at or
/B
LD
G P
2-
4-
S.
rv t 3/
7/
1:
:1
AM
W
IN
D
LO
AD
C
O M
PO
N
EN
T
AN
D
C
LA
DD
IN
G
SITMMIDB
S-003
CA
RI
C O
D
EL
V
EN
TO
S
U C
O M
PO
N
EN
TI
E R
IV
ES
TI
M
EN
TI
14125428
JTW
C&C ULTIMATE WIND PRESSURES-MONOSLOPE ROOF (kPa) LOWER BUILDING/ PRESSIONE ULTIMA SU TETTO MONOPENDENTE CON COMPONENTI E RIVESTIMENTO (kPa) LOWER BUILDING
SURFACE /
SUPERFICIE ZONE / ZONA
EFFECTIVE WIND AREAS (SQM) / AREE EFFETTIVE DI VENTO
(MQ) BUILDING / EDIFICIO
1 2 5 9
ROOF FIELD / TETTO 1 0.46/-1.16 0.44/-1.11 0.42/-1.07 0.38/-1.01 LOWER BUILDING
ROOF EDGE / BORDO
TETTO 2 0.46/-1.4 0.44/-1.32 0.42/-1.16 0.38/-1.08 LOWER BUILDING
ROOF CORNER /
ANGOLO TETTO 3 0.46/-2.42 0.44/-2.19 0.42/-1.95 0.38/-1.71 LOWER BUILDING
C&C ULTIMATE WIND PRESSURES - WALLS (kPa) / PRESSIONE ULTIMA SU MURI COMPRESI DI COMPONENTI E RIVESTIMENTO (kPa)
SURFACE / SUPERFICIE ZONE / ZONA
EFFECTIVE WIND AREAS (SQM) / AREE EFFETTIVE DI VENTO
(MQ) BUILDING / EDIFICIO
1 2 5 9
WALL FIELD / MURO 4 1.1/-1.19 1.05/-1.14 0.96/-1.1 0.91/-1.05 LOWER BUILDING
WALL CORNER /
ANGOLO MURO 5 1.1/-1.47 1.05/-1.37 0.96/-1.23 0.91/-1.14 LOWER BUILDING
WALL FIELD / MURO 4 0.93/-1.01 0.89/-0.97 0.81/-0.93 0.77/-0.89 SIM BAY
WALL CORNER /
ANGOLO MURO 5 0.93/-1.24 0.89/-1.16 0.81/-1.05 0.77/-0.97 SIM BAY
C&C ULTIMATE WIND PRESSURES-MONOSLOPE ROOF (kPa) SIM BAY/ PRESSIONE ULTIMA SU TETTO MONOPENDENTE CON...
SURFACE / SUPERFICIE ZONE / ZONA
EFFECTIVE WIND AREAS (SQM) / AREE EFFETTIVE DI VENTO
(MQ)
BUILDING / EDIFICIO1 2 5 9
ROOF FIELD / TETTO 1 0.45/-1.19 0.43/-1.19 0.38/-1.19 0.35/-1.19 SIM BAY
ROOF EDGE / BORDO
TETTO
2 0.45/-1.37 0.43/-1.35 0.38/-1.31 0.35/-1.28 SIM BAY
ROOF EDGE / BORDO
TETTO
2' 0.45/-1.65 0.43/-1.63 0.38/-1.59 0.35/-1.56 SIM BAY
ROOF CORNER / ANGOLO
TETTO
3 0.45/-1.84 0.43/-1.65 0.38/-1.47 0.35/-1.28 SIM BAY
ROOF CORNER / ANGOLO
TETTO
3' 0.45/-2.58 0.43/-2.3 0.38/-1.93 0.35/-1.65 SIM BAY
S-201 A1
S-202 A1
S-201 C1
S-202 C1
D
C
F
H
E
876543
18170 75 4775 7105 5215 6625 3135
19770 26130
1575 1000 2915 260 240
7205 4975 75 4775 1420
6290 18955
B
4'21
G
I
A
-1.60
-1.60
C1 S-301
C1 S-301
A1 S-301
A1 S-301
-1.60
-2.20
-1.60 -1.60 -1.60
EXISTING BUILDING FOUNDATION
S-501 A1
S-502 A1
S-503 A1
-1.60
-1.60
-1.60
-1.60
A2 S-507
A1 S-507
C1 S-507
-1.30
C3 S-507
1000 2915
C2 S-507
A3 S-507
700 1870 700 2225 1000
D1
S-509
D2 S-511
B3 S-514
D1 S-511
1:100
0 1 32 4 5 10
SCALE:SCALE:
PLAN
NORTH
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
1684614
11/07/22
Richard Tyler, PE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
100 AIRSIDE DRIVE
MOON TOWNSHIP, PA 15108
AV
IA
N O
A
IR
B
AS
E
AV
IA
N
O , I
TA
LY
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
FI
LE
N
AM
E:
PL
OT
TE
D:
LMM / BTN
FIRE PROTECTION DPS
F2
AD
AL
C O
M
BA
T R
ES
C
U E
H
EL
IC
O
PT
ER
SI
M
U
LA
TO
R
F
AC
IL
IT
Y (P
2)
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N S
TR
U
C
TI
O N
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
DRAWFORM REVISION: 12 APRIL 2018
ISSUED FOR CONSTRUCTION – 10 MAR 2023
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD AS NOTED
BI
M
P
Si m ul at or
/B
LD
G P
2-
4-
S.
rv t 3/
7/
1:
:1
AM
FO
U
ND
AT
IO
N
PL
AN
SITMMIDB
S-101
PI
AN
TA
F
O N
D
AZ
IO
NI
14125429
JTW
SCALE: 1 : 100
FOUNDATION PLAN / PIANTA FONDAZIONIA1
NOTES - FOUNDATION PLAN / NOTE - PIANTA
FONDAZIONI
1 REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS / QUOTA DI RIFERIMENTO 0,0
= VEDERE I DISEGNI CIVILI
2 REFER TO SHEETS S-001 AND S-002 FOR STRUCTURAL GENERAL NOTES / FARE
RIFERIMENTO ALLE TAVOLE S-001 E S-002 PER LE NOTE STRUTTURALI
GENERICHE
3 TOP OF FOUNDATION ELEVATION IS -1600 mm UON / QUOTA TESTA FONDAZIONE 1600 mm SE NON DIVERSAMENTE SPECIFICATO
4 REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO
BUILDING / FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI DEL
TERRENO ADIACENTI ALL'EDIFICIO
5 DURING THE EXCAVATION, EVALUATE THE POSITION OF THE EXISTING
FOUNDATION AND REPORT TO THE DIRECTOR OF WORK IF THERE ARE
INTERFERENCES / DURANTE LO SCAVO VALUTARE LA POSIZIONE DELLA
FONDAZIONE ESISTENTE E SEGNALARE AL DIRETTORE DEI LAVORI SE CI SONO
INTERFERENZE
6 THE EXISTING FOUNDATION POSITION AND GEOMETRIES OF BUILDING B7300
HAVE BEEN EVALUATED WITH REFERENCES TO THE FINAL DESIGN DRAWINGS
PROVIDED BY THE CLIENT / LA POSIZIONE DELLA FONDAZIONE ESISTENTE E LE
GEOMETRIE DELL'EDIFICIO B7300 SONO STATE VALUTATE CON RIFERIMENTO AI
DISEGNI DI PROGETTAZIONE ESECUTIVA FORNITI DAL CLIENTE
7 CONTRACTOR TO VERIFY THE ACTUAL POSITION OF THE EXISTING FOUNDATION
TO IDENTIFY POSSIBLE INTERFERENCE BETWEEN NEW AND EXISTING
FOUNDATION / IN FASE DI INIZIO ATTIVITÀ SARÀ ONERE DELL'APPALTATORE
VERIFICARE L'EFFETTIVO POSIZIONAMENTO E TRACCIAMENTO DELLE OPERE DI
FONDAZIONE ESISTENTI, NELLO SPECIFICO IN RIFERIMENTO ALLE POSSIBILI
INTERFERENZE
KEYNOTES / NOTE CHIAVE
2 TYCAL REINFORCED FOUNDATION 1000x500 mm, REFER TO SHEET
S-502-3 / TIPOLOGICO FONDAZIONE IN CA 1000x500 mm, FARE
RIFERIMENTO ALLA TAVOLA S-502-3
3 TYPICAL REINFORCED GRADE BEAM 500x500 mm, REFER TO SHEET S-502-3 / TIPOLOGICO TRAVE DI COLLEGAMENTO IN CA 500x500 mm, FARE
RIFERIMENTO ALLA TAVOLA S-502-3
4 TYPICAL FOUNDATION PLINTH 1500x1500x500 mm, REFER TO SHEET S-502-3 / TIPOLOGICO PLINTO DI FONDAZIONE 1500x1500x500 mm, FARE
RIFERIMENTO ALLA TAVOLA S-502-3
5 TYPICAL REINFORCED FOUNDATION 1600x500 mm, REFER TO SHEET S-501-2-3 / TIPOLOGICO FONDAZIONE IN CA 1600x500 mm, FARE
RIFERIMENTO ALLA TAVOLA S-501-2-3
6 FOUNDATION PLINTH 2780x1500x500 mm, REFER TO SHEET S-503 / PLINTO DI FONDAZIONE 2780x1500x500 mm, FARE RIFERIMENTO ALLA TAVOLA S-503
43 FOUNDATION PLINTH 3560x1500x500 mm / PLINTO DI FONDAZIONE 3560x1500x500 mm
92 TYPICAL REINFORCED FOUNDATION 1000x300 mm / TIPOLOGICO FONDAZIONE IN CA 1000x300 mm
96 FENCE FOUNDATION 1000x700x300 mm / FONDAZIONE RECINZIONE 1000x700x300
97 FENCE FOUNDATION 1665x1000x300 mm / FONDAZIONE RECINZIONE 1665x1000x300
98 FENCE FOUNDATION 1640x1000x300 mm / FONDAZIONE RECINZIONE 1640x1000x300
S-202 A1
S-201 C1
S-202 C1
D
C
F
H
E
876543
18570 26355
B
4'21
G
I
A
C1 S-301
C1 S-301
A1 S-301
A1 S-301
6065 5200 1800 360 1800 3345
-0.81
-1.31
-0.15
2185 1800 2200 6200 6185 9420 2345 900
2050 8555 2050 670 5990 7205 4975 75 4775 7105 5215 6625 2635
-0.15
8%
-0.57-0.81 8%8%
-0.57
-0.81
-0.81
3775 115 250 6980 5350 3975 1800 525 18885
B4 S-508
A1 S-507
C1 S-507
-0.57 0.000.00
C2 S-507
A3 S-507
100 100
D1 S-511
100 100
LEGEND / LEGENDA:
200 mm CAST-IN-PLACE CONCRETE SLAB OVER MODULAR IGLU SYSTEM / 200 mm SOLETTA IN CLS GETTATO IN OPERA SU
VESPAI A IGLU
MODULAR IGLU SYSTEM 70 mm THICK SLAB / VESPAI A IGLU 70 mm SPESSORE SOLETTA
250 mm CAST-IN-PLACE CONCRETE SLAB OVER LEAN CONCRETE
WELL COMPACTED FILL, VAPOR RETARDER AND RADON BARRIER /
250 mm SOLETTA IN CLS GETTATO IN OPERA SU MAGRONE E
TERRENO COMPATTATO, BARRIERA AL VAPORE E BARRIERA AL
RADON
INDICATES 3⌀20 TOP BAR AT EACH CORNER/DISCONTINUITY
POINT IN THE SLAB L= 500 mm / INDICA BARRE SUPERIORI DA 3⌀
20 IN OGNI ANGOLO/PUNTO DI DISCONTINUITÀ DELLA SOLETTA
L= 500 mm
DENOTES SLAB-STEP / INDICA SCALINO SULLA SOLETTA
200 mm CAST-IN-PLACE CONCRETE SLAB OVER WELL COMPACTED FILL, VAPOR RETARDER AND RADON BARRIER / 250 mm SOLETTA
IN CLS GETTATO IN OPERA SU TERRENO COMPATTATO, BARRIERA
AL VAPORE E BARRIERA AL RADON
1:100
0 1 32 4 5 10
SCALE:SCALE:
PLAN
NORTH
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
1684614
11/07/22
Richard Tyler, PE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
100 AIRSIDE DRIVE
MOON TOWNSHIP, PA 15108
AV
IA
N O
A
IR
B
AS
E
AV
IA
N
O , I
TA
LY
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
FI
LE
N
AM
E:
PL
OT
TE
D:
LMM / BTN
FIRE PROTECTION DPS
F2
AD
AL
C O
M
BA
T R
ES
C
U E
H
EL
IC
O
PT
ER
SI
M
U
LA
TO
R
F
AC
IL
IT
Y (P
2)
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N S
TR
U
C
TI
O N
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
DRAWFORM REVISION: 12 APRIL 2018
ISSUED FOR CONSTRUCTION – 10 MAR 2023
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD AS NOTED
BI
M
P
Si m ul at or
/B
LD
G P
2-
4-
S.
rv t 3/
7/
1:
:1
AM
G R
O
UN
D F
LO
O
R F
R
AM
IN
G
P
LA
N
SITMMIDB
S-102
PI
AN
TA
S
TR
UT
TU
R
AL
E
PI
AN
O T
ER
R
A
14125430
JTW
SCALE: 1 : 100
GROUND FLOOR FRAMING PLAN / PIANTA STRUTTURALE PIANO TERRAA1
KEYNOTES / NOTE CHIAVE
7 REINFORCED CONCRETE WALL 250 mm, REFER TO SHEET S-203-5-6-7 / MURO IN
CA 250 mm, FARE RIFERIMENTO ALLA TAVOLA S-203-5-6-7 8 MODULAR IGLU SYSTEM WITH 70 mm THICK SLAB / VESPAIO A IGLU CON
SOLETTA DA 70 mm 9 200 mm CAST-IN-PLACE CONCRETE SLAB OVER MODULAR IGLU SYSTEM /
SOLETTA GETTATA IN OPERA DA 200 mm SU VESPAIO A IGLU 10 REINFORCED CONCRETE COLUMN 400x400 mm WITH 12D20 AND D10/12
STIRRUPS, REFER TO DETAIL B3 IN SHEET S-510 / COLONNA IN CA 400x400 mm
CON FERRI 12D20 E STAFFE D10/12 , FARE RIFERIMENTO AL DETTAGLIO B3
NELLA TAVOLA S-510
11 REINFORCED CONCRETE WALL 400 mm, REFER TO SHEET S-203-4-5-6 / MURO IN CA 400 mm , FARE RIFERIMENTO ALLA TAVOLA S-203-4-5-6
44 COORDINATE THE POSITION OF THE CUNICLES WITH THE SUPPLIER OF THE
SIMULATOR / COORDINARE LA POSIZIONE DEI CUNICOLI CON IL FORNITORE DEL
SIMULATORE
45 REINFORCED CONCRETE WALL 200 mm / MURO IN CA 200 mm 100 100mm HOUSEKEEPING CONCRETE PAD OVER SLAB ON GRADE / SOLETTA DI
PULIZIA IN CA SU PAVIMENTAZIONE INDUSTRIALE SP 100mm
NOTES - GROUND FLOOR FRAMING PLAN / NOTE -
PIANTA STRUTTURALE PIANO TERRA
1 REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS / QUOTA DI
RIFERIMENTO 0,0 = VEDERE I DISEGNI CIVILI
2 REFER TO SHEETS S-001 AND S-002 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE S-001 E S-002 PER LE NOTE
STRUTTURALI GENERICHE
3 REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT
TO BUILDING / FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE
SUPERIORI DEL TERRENO ADIACENTI ALL'EDIFICIO
4 DURING THE EXCAVATION, EVALUATE THE POSITION OF THE EXISTING
FOUNDATION AND REPORT TO THE DIRECTOR OF WORK IF THERE ARE
INTERFERENCES / DURANTE LO SCAVO VALUTARE LA POSIZIONE DELLA
FONDAZIONE ESISTENTE E SEGNALARE AL DIRETTORE DEI LAVORI SE CI
SONO INTERF
5 COORDINATE THE POSITION AND THE DIMENSION OF THE HOUSEKEEPING
PAD WITH THE EQUIPMENT PROVIDED / COORDINARE LA POSIZIONE E LA
DIMENSIONE DELLE SOLETTE DI PULIZIA CON IL FORNITORE DEI
MACCHINARI
6 REFER TO CIVIL DRAWINGS FOR THE EXTERNAL PAVEMENTS / FARE
RIFERIMENTO AI DISEGNI CIVILI PER LE PAVIMENTAZIONI ESTERNE
S-202 A1
S-201 C1
S-202 C1
D
C
F
H
E
876543
7205 5050 4775
18170 4850 7105 5215 6625 2635 18570 26355
0 .
B
4'21
G
I
A
5.38
4.16
C1 S-301
C1 S-301
A1 S-301
A1 S-301
EXISTING ROOF
20%20%
5%
5%
S-504 A1
S-505 A1
4.23 4.23
5.49
H = 25 + 5 (TYP.)
H = 25 + 5 (TYP.)
C3 S-509
A3 S-510
A1 S-509
A1 S-510
A1 S-508
C2 S-508
15 15
LEGEND / LEGENDA:
INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD BEARING
CONCRETE WALL L = 1200 mm / INDICA BARRE SAGOMATE ø20
OGNI 300 O.C. NEL MURO DI CEMENTO ARMATO PORTANTE L =
1200 mm
1:100
0 1 32 4 5 10
SCALE:SCALE:
PLAN
NORTH
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
1684614
11/07/22
Richard Tyler, PE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
100 AIRSIDE DRIVE
MOON TOWNSHIP, PA 15108
AV
IA
N O
A
IR
B
AS
E
AV
IA
N
O , I
TA
LY
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
FI
LE
N
AM
E:
PL
OT
TE
D:
LMM / BTN
FIRE PROTECTION DPS
F2
AD
AL
C O
M
BA
T R
ES
C
U E
H
EL
IC
O
PT
ER
SI
M
U
LA
TO
R
F
AC
IL
IT
Y (P
2)
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N S
TR
U
C
TI
O N
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
DRAWFORM REVISION: 12 APRIL 2018
ISSUED FOR CONSTRUCTION – 10 MAR 2023
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD AS NOTED
BI
M
P
Si m ul at or
/B
LD
G P
2-
4-
S.
rv t 3/
7/
1:
:1
AM
RO
O
F
FR
AM
IN
G P
LA
N
SITMMIDB
S-103
PI
AN
TA
S
TR
UT
TU
R
AL
E
TE
TT
O
14125431
JTW
SCALE: 1 : 100
ROOF FRAMING PLAN / PIANTA STRUTTURALE COPERTURAA1
NOTES - ROOF FRAMING PLAN / NOTE - PIANTA
STRUTTURALE TETTO
1 REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS / QUOTA DI RIFERIMENTO
0,0 = VEDERE I DISEGNI CIVILI
2 REFER TO SHEETS S-001 AND S-002 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE S-001 E S-002 PER LE NOTE STRUTTURALI
GENERICHE
3 REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO
BUILDING / FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI
DEL TERRENO ADIACENTI ALL'EDIFICIO
4 COORDINATE THE ROOF OPENING DETAILS WITH THE MANUFACTURER OF
THE PREDALLES SLAB / COORDINARE I DETTAGLI DEI FORI SUL TETTO CON IL
PRODUTTORE DELLE PREDALLES
5 SEE MEP AND ARCH DRAWINGS FOR ALL NECESSARY HOLES BEFORE
POURING / VEDERE I DISEGNI MEP E ARCH PER TUTTI I FORI NECESSARI
PRIMA DI ESEGUIRE IL GETTO
KEYNOTES / NOTE CHIAVE
13 300 mm CAST-IN-PLACE REINFORCED CONCRETE PREDALLES SLAB / SOLETTA
CON PREDALLES IN CA DA 300 mm 14 300 mm CAST-IN-PLACE REINFORCED CONCRETE SLAB, D16/200 TOP AND
BOTTOM IN BOTH DIRECTION / SOLETTA IN CA GETTATA IN OPERA DA 300 mm, D16/200 SUPERIORE E INFERIORE SU ENTRAMBE LE DIREZIONI
15 REINFORCED CONCRETE BEAM 300x500 mm / TRAVE IN CA 300x500 mm 16 REINFORCED CONCRETE BEAM 500x250 mm / TRAVE IN CA 500x250 mm 30 EXPANSION JOINT BETWEEN NEW AND EXISTING BUILDINGS Thk = 100 mm /
GIUNTO DI ESPANSIONE TRA GLI EDIFICI ESISTENTI E NUOVI Sp = 100mm 53 REINFORCED CONCRETE BEAM 300x550 mm / TRAVE IN CA 300x550 mm
S-202 A1
S-201 C1
S-202 C1
D
C
F
H
E
876543
B
4'21
G
I
A
10.41
10.41
C1 S-301
C1 S-301
A1 S-301
A1 S-301
S-506 A1
20%20%
5% 5%
2740 2540 710 1825 2540 2540 300 2240 2740 75
S-508 A3
TR
U
SS
TR
U
SS
TR
U
SS
TR
U
SS
TR
U
SS
TR
U
SS
NODE 8
NODE 10
NODE 9
1:100
0 1 32 4 5 10
SCALE:SCALE:
PLAN
NORTH
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
1684614
11/07/22
Richard Tyler, PE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
100 AIRSIDE DRIVE
MOON TOWNSHIP, PA 15108
AV
IA
N O
A
IR
B
AS
E
AV
IA
N
O , I
TA
LY
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
FI
LE
N
AM
E:
PL
OT
TE
D:
LMM / BTN
FIRE PROTECTION DPS
F2
AD
AL
C O
M
BA
T R
ES
C
U E
H
EL
IC
O
PT
ER
SI
M
U
LA
TO
R
F
AC
IL
IT
Y (P
2)
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N S
TR
U
C
TI
O N
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
DRAWFORM REVISION: 12 APRIL 2018
ISSUED FOR CONSTRUCTION – 10 MAR 2023
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD AS NOTED
BI
M
P
Si m ul at or
/B
LD
G P
2-
4-
S.
rv t 3/
7/
1:
:1
AM
SI
M
U
LA
TO
R
B
AY
R O
O F
FR
AM
IN
G
P
LA
N
SITMMIDB
S-104
PI
AN
TA
S
TR
UT
TU
R
AL
E
TE
TT
O S
IM
U
LA
TO
R B
AY
14125432
JTW
SCALE: 1 : 100
SIMULATOR BAY ROOF FRAMING PLAN / PIANTA STRUTTURALE COPERTURA SIMULATOR BAYA1
NOTES - SIMULATOR BAY ROOF FRAMING PLAN /
NOTE - PIANTA STRUTTURALE TETTO SIM BAY
1 REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS / QUOTA DI RIFERIMENTO
0,0 = VEDERE I DISEGNI CIVILI
2 REFER TO SHEETS S-001 AND S-002 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE S-001 E S-002 PER LE NOTE STRUTTURALI
GENERICHE
3 REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO
BUILDING / FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI
DEL TERRENO ADIACENTI ALL'EDIFICIO
KEYNOTES / NOTE CHIAVE
38 SANDWICH PANELS DIRECTION, REFER TO ARCH DRAWINGS / ORDITURA
PANNELLI SANDWICH
56 CONTINUOUS CANTILEVER CONCRETE BEAM, REFER TO DETAIL b3 IN
SHEET S-509/ TRAVE A SBALZO IN CA, FARE RIFERIMENTO AL DETTAGLIO
b3 NELLA TAVOLA S-509
68 HEA 100
69 HEA 200
71 2xL 80x7 mm
GROUND FLOOR
TOP OF
FOUNDATION
-1600
DC F HEB G IA
SIM BAY TOW
13680
TOP OF CLAY
TILES ROOF SLAB
TOP OF ROOF
SLAB
3610 7025 1800 3435 2700 9660
S-203 C2
S-203 A1
3535 3965 2160 3640 1395 3480 3695 6040
11.64
10%
35%
5.38
-0.57
GROUND FLOOR
TOP OF
FOUNDATION
-1600
D CFH E BGI A
SIM BAY TOW
13680
TOP OF CLAY
TILES ROOF SLAB
TOP OF ROOF
SLAB
18570
S-206 A1
S-206 A3
6040 3695 3480 1395 3640 2160 3965 3535
10%
35% 5.49
11.64
92 2 1:100
0 1 32 4 5 10
SCALE:SCALE:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
1684614
11/07/22
Richard Tyler, PE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
100 AIRSIDE DRIVE
MOON TOWNSHIP, PA 15108
AV
IA
N O
A
IR
B
AS
E
AV
IA
N
O , I
TA
LY
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
FI
LE
N
AM
E:
PL
OT
TE
D:
LMM / BTN
FIRE PROTECTION DPS
F2
AD
AL
C O
M
BA
T R
ES
C
U E
H
EL
IC
O
PT
ER
SI
M
U
LA
TO
R
F
AC
IL
IT
Y (P
2)
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N S
TR
U
C
TI
O N
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
DRAWFORM REVISION: 12 APRIL 2018
ISSUED FOR CONSTRUCTION – 10 MAR 2023
GRAPHIC SCALE
SCALA GRAFICA AS NOTED
BI
M
P
Si m ul at or
/B
LD
G P
2-
4-
S.
rv t 3/
7/
1:
:1
AM
FA
CA
D E
EL
EV
AT
IO
NS
SITMMIDB
S-201
PR
O
SP
ET
TI
14125433
JTW
SCALE: 1 : 100
FACADE ELEVATION EST / PROSPETTO ESTC1
SCALE: 1 : 100
FACADE ELEVATION WEST / PROSPETTO OVESTA1
NOTES - FACADE ELEVATION / NOTE - PROSPETTI
1 REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS / QUOTA DI RIFERIMENTO
0,0 = VEDERE I DISEGNI CIVILI
2 REFER TO SHEETS S-001 AND S-002 FOR STRUCTURAL GENERAL NOTES /
FARE RIFERIMENTO ALLE TAVOLE S-001 E S-002 PER LE NOTE STRUTTURALI
GENERICHE
3 TOP OF FOUNDATION ELEVATION IS -1600 mm UON / QUOTA TESTA FONDAZIONE 1600 mm SE NON DIVERSAMENTE SPECIFICATO
4 REFER TO CIVIL DRAWINGS FOR…