Attachment K - 1684614dwg15of16.pdf

PDF 2 MB Posted

Attached to
P242 Combat Rescue Helicopter Simulator Facility Federal contract opportunity
Solicitation number
N6247023R0003
Issued by
Department of the Navy Naval Facilities Engineering Command

View the file

Other files for this federal contract opportunity

Other files attached to P242 Combat Rescue Helicopter Simulator Facility, newest first.
File Type Posted
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Attachment K - Civil Drawings - Addendum1_REVISED.pdf PDF
Attachment K - Architecture Drawings - Addendum1_REVISED.pdf PDF
Amendment 0003.pdf PDF
Attachment N -B7300.pdf PDF
Attachment M - Safety and Coordination Plan_ITALIAN.pdf PDF
Attachment L - Safety and Coordination Plan_ENGLISH.pdf PDF
Amendment 0002.pdf PDF
P242 Amendment 0001.pdf PDF
Attachment K - 1684614dwg12of16.pdf PDF
Attachment I - INSTALLATION ACCESS REQUEST.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
P242 Solicitation.pdf PDF
Attachment K - 1684614dwg9of16.pdf PDF
Attachment K - 1684614dwg6of16.pdf PDF
Attachment K - 1684614dwg7of16.pdf PDF
Attachment K - 1684614dwg16of16.pdf PDF
Attachment K - 1684614dwg2of16.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Attachment K - 1684614dwg4of16.pdf PDF
Attachment K - 1684614dwg8of16.pdf PDF
Attachment K - 1684614dwg14of16.pdf PDF
Attachment K - 1684614dwg11of16.pdf PDF
Attachment K - 1684614dwg1of16.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment E - Price Proposal Form.pdf PDF
Attachment C - Construction Experience Project Data Sheet (1).pdf PDF
Attachment J -Specifications.pdf PDF
Attachment K - 1684614dwg5of16.pdf PDF
Attachment K - 1684614dwg13of16.pdf PDF
Attachment K - 1684614dwg10of16.pdf PDF
Attachment K - 1684614dwg3of16.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - Informazione Antimafia.pdf PDF
Attachment G - Comunicazione Antimafia.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TELECOMMUNICATIONS ABBREVIATIONS

SYMBOL / SYMBOLO SECURITY PLAN / PIANO DI

SICUREZZA

CA

ES

AI

J

HSS

PS

REX

CR

VJB

SECURITY CAMERA / TELECAMERA DI SICUREZZA

ACCESS CONTROL SYSTEM CARD ACCESS / ACCESSO CON CARTA SISTEMA DI

CONTROLLO D'ACCESSO

ACCESS CONTROL SYSTEM CARD READER. / LETTORE CARTA SISTEMA DI

CONTROLLO D'ACCESSO

ACCESS CONTROL SYSTEM DOOR ELECTRIC STRIKE. / INCONTRO ELETTRICO

PORTA SISTEMA DI CONTROLLO D'ACCESSO

ACCESS CONTROL SYSTEM INTERCOM / CITOFONO SISTEMA DI CONTROLLO D'ACCESSO

ACCESS CONTROL SYSTEM POWER SUPPLY / ALIMENTAZIONE ELETTRICA

SISTEMA DI CONTROLLO D'ACCESSO

ACCESS CONTROL HIGH SECURITY SWITCH. / INTERRUTTORE A

ELEVATA SICUREZZA CONTROLLO D'ACCESSO

ACCESS CONTROL SYSTEM REQUEST TO EXIT / RICHIESTA

D'USCITA SISTEMA DI CONTROLLO D'ACCESSO

ACCESS CONTROL SYSTEM CENTRAL VIDEO JUNCTION BOX / CASSETA

DI DERIVAZIONE VIDEO CENTRALE SISTEMA DI CONTROLLO D'ACCESSO

CEILING MOUNTED SECURITY JUNCTION BOX / CASSETA DI

DERIVAZIONE DI SICUREZZA A SOFFITTO

J WALL MOUNTED SECURITY JUNCTION BOX / CASSETTA DI

DERIVAZIONE DI SICUREZZA A PARETE.

DC ACCESS CONTROL DOOR CONTACT / CONTATTO PORTA CONTROLLO

D'ACCESSO

SECURITY CAMERA WITH PAN, TILT, ZOOM CAPABILITIES / TELECAMERA DI SICUREZZA

CON FUNZIONALITÀ PAN/ TILT/ ZOOM

PTZ

GENERAL / GENERALESYMBOL / SYMBOLO

00.00 SHEET KEYNOTE / NOTE PRINCIPALI SCHEDA

TELECOMMUNICATIONS INSTALLATION SHALL COMPLY WITH THE MOST CURRENT VERSION OF THE

FOLLOWING STANDARDS:

I3A - TECHNICAL CRITERIA FOR THE INSTALLATION INFORMATION INFRASTRUCTURE ARCHITECTURE

OUTSIDE PLANT DESIGN AND PERFORMANCE REQUIREMENTS (OSPDPR)

ANSI/TIA-568.0-D : GENERIC TELECOMMUNICATIONS CABLING FOR CUSTOMER PREMISES

ANSI/TIA-568.1-D : COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD

TIA/EIA-569-C : TELECOMMUNICATIONS PATHWAYS AND SPACE

TIA/EIA-568-C.0 : GENERIC BUILDING TELECOMMUNICATIONS CABLING FOR CUSTOMER PREMISES

TIA/EIA-568-C.1 : COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD

ANSI/TIA-568-C.2 : BALANCED TWISTED PAIR TELECOMMUNICATIONS CABLING

AND COMPONENT STANDARD

ANSI/TIA-568.3-D : OPTICAL FIBER CABLING COMPONENTS STANDARD

ANSI/TIA-568.4-D : BROADBAND COAXIAL CABLING AND COMPONENTS STANDARD

ANSI/TIA-569-C, 2012 : TELECOMMUNICATIONS PATHWAYS AND SPACES

ANSI/TIA-606-B : ADMINISTRATION STANDARD FOR COMMERCIAL TELECOMMUNICATIONS

INFRASTRUCTURE

TIA-526-7 (OFSTP-7)-2002+A1:2008 : MEASUREMENT OF OPTICAL POWER LOSS OF INSTALLED SINGLE-MODE

FIBER CABLE PLANT

ANSI/TIA-607-B, 2011 : COMMERCIAL BUILDING GROUNDING (EARTHING) AND

BONDING REQUIREMENTS FOR TELECOMMUNICATIONS

ANSI/TIA-1152, 2009: REQUIREMENTS FOR FIELD TEST INSTRUMENTS AND MEASUREMENTS FOR

BALANCED TWISTED-PAIR CABLING

ANSI/TIA-942A : TELECOMMUNICATIONS INFRASTRUCTURE STANDARDS FOR DATA CENTERS

TIA TSB-162-A, 2013 : TELECOMMUNICATIONS CABLING GUIDELINES FOR WIRELESS ACCESS POINTS

ANSI/NECA/BICSI 568 : STANDARD FOR INSTALLING COMMERCIAL BUILDING TELECOMMUNICATIONS

CABLING

NFPA 70 : NATIONAL ELECTRICAL CODE (NEC)

NFPA 75 : STANDARD FOR THE PROTECTION OF INFORMATION TECHNOLOGY EQUIPMENT

NFPA 76 : STANDARD FOR THE FIRE PROTECTION OF TELECOMMUNICATIONS FACILITIES

MIL-HDBK-232A : RED/BLACK ENGINEERING-INSTALLATION GUIDELINES

TM 5-853-4 CORPS OF ENGINEERS ELECTRONIC SECURITY SYSTEMS TECHNICAL MANUAL

IC-TECH SPEC ICD/ICS 705, ICS-705-1, ICS-705-2

CoSC ISP INSTALLATION STANDARDS VERSION 1.0, 16 MAY 2011

SIPRNET TECHNICAL CRITERIA : SECRET INTERNET PROTOCOL ROUTER NETWORK (SIPRNET) TECHNICAL

IMPLEMENTATION CRITERIA

UFC 4-020-04A : ELECTRONIC SECURITY SYSTEMS : SECURITY ENGINEERING

UFC 4-010-05 : SENSITIVE COMPARTMENTED INFORMATION FACILITIES PLANNING, DESIGN AND

CONSTRUCTION

UFC 3-580-01 : TELECOMMUNICATIONS BUILDING CABLING SYSTEMS PLANNING AND DESIGN

UFC 4-020-04A : ELECTRONIC SECURITY SYSTEMS : SECURITY ENGINEERING

MIL-HDBK-1012/3 : TELECOMMUNICATIONS PREMISES DISTRIBUTION PLANNING, DESIGN AND ESTIMATING

USASOC IT TECHNICAL GUIDE

AR 380-5 - DEPARTMENT OF THE ARMY INFORMATION SECURITY PROGRAM

AR 380-27 - (FOUO) CONTROL OF COMPROMISING EMANATIONS

AR 380-40 - SAFEGUARDING AND CONTROLLING COMMUNICATIONS SECURITY MATERIAL

CNSSAM TEMPEST/1-13 - (U) RED/BLACK INSTALLATION GUIDANCE

CNSSI 7003 PROTECTED DISTRIBUTION SYSTEMS (PDS)

USASOC REG 380-40 COMMUNICATIONS SECURITY (COMMSEC) PROTECTED DISTRIBUTION SYSTEM (PDS)

USGS 27 05 29.00 10 PROTECTED DISTRIBUTION SYSTEM (PDS) FOR SIPRNET COMMUNICATIONS SYSTEMS

NSTISSI NO. 7003 PROTECTIVE DISTRIBUTION SYSTEMS (PDS)

USASOC INFORMATION TECHNOLOGY (IT) TECHNICAL DESIGN GUIDE

SECRET INTERNET PROTOCOL ROUTER NETWORK (SIPRNET) TECHNICAL IMPLEMENTATION CRITERIA

DoDD 8100.02 – (U) USE OF WIRELESS DEVICES, SERVICES, AND TECHNOLOGIES IN THE DEPARTMENT OF DEFENSE (DoD) GLOBAL INFORMATION GRID (GIG)

MIL-HDBK-419A : GROUNDING, BONDING AND SHIELDING FOR ELECTRONIC EQUIPMENT AND FACILITIES

MIL-STD-188-124B (U) GROUNDING, BONDING, AND SHIELDING FOR COMMON LONG-HAUL/TACTICAL COMMUNICATIONS SYSTEMS, INCLUDING GROUND BASED COMMUNICATION ELECTRONICS FACILITIES

FOR EQUIPMENT

RUS BULLETIN 1751F-640, DESIGN OF BURIED PLANT - PHYSICAL CONSIDERATIONS

RUS BULLETIN 1751F-644, 2002 - UNDERGROUND PLANT CONSTRUCTION

ICEA S-87-640, 2011 - OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

ICEA S-98-688, 2012 - BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFIN INSULATED, COPPER

CONDUCTORS TECHNICAL REQUIREMENTS

ICEA S-99-689, 2012 - BROADBAND TWISTED PAIR CABLE FILLED, POLYOLEFIN INSULATED, COPPER

CONDUCTORS TECHNICAL REQUIREMENTS

SYMBOL TELECOMMUNICATIONS PLAN

STANDARD WORK AREA OUTLET (WAO), UNCLASSIFIED; TWO (2) CATEGORY 6 UTP 4-PAIR

COPPER CABLES, WITH OVERALL GREEN JACKET, INSTALLED ON FOUR-PORT

FACEPLATE, WITH TWO PORTS LEFT BLANK, AT DEVICE LOCATION, MOUNTED AT 460" AFF

WALL-MOUNTED WORK AREA OUTLETS (WAOs) TO BE INSTALLED WITH MINIMUM 32mm CONDUIT FROM ACCESSIBLE CEILING (OR ACCESSIBLE RAISED ACCESS FLOOR) TO FLUSH-MOUNTED 130mm SQUARE

WALL JUNCTION BOX LOCATION FITTED WITH SINGLE GANG REDUCER RING WITH PULL STRING

INSTALLED. T568A TERMINATIONS SHALL BE PERFORMED USING 8P8C RJ45 KEYSTONE TYPE OUTLET CONNECTOR MODULES RATED FOR THE CATEGORY OF THE INSTALLED CABLE. ALL CABLING SHALL BE UL-LISTED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED: PLENUM, RISER, OR UNLISTED FOR OSP

CABLING.

TELECOMMUNICATIONS STANDARDS TELECOMMUNICATIONS GENERAL NOTES

1. THIS IS A STANDARD LEGEND SHEET. NOT ALL SYMBOLS OR ABBREVIATIONS MAY APPEAR ON

DRAWINGS.

2. REFER TO DIVISIONS 26, 27, 28 AND 33 SPECIFICATIONS FOR TELECOMMUNICATION SYSTEM

ITEMS.

3. MOUNTING DEVICES AND EQUIPMENT PER SPECIFICATIONS UNLESS OTHERWISE NOTED.

4. MOUNTING HEIGHTS, UNLESS OTHERWISE NOTED, ARE TO CENTER LINE OF DEVICE.

5. THE CONTRACTOR SHALL DETERMINE THE EXACT ROUTING OF RACEWAYS.

6. THE CONTRACTOR SHALL COORDINATE ALL RACEWAY PENETRATIONS AND PROVIDE

FIREPROOFING AS APPLICABLE.

7. THE MAXIMUM PERMANENT HORIZONTAL LINK DISTANCE SHALL BE 90M AND THE MAXIMUM

HORIZONTAL CHANNEL (LINK PLUS WORKSTATION CABLES AND PATCH CORDS) SHALL BE 100M.

8. ALL HORIZONTAL CABLING SHALL BE CAT 6 INSTALLED IN A MINIMUM 41mm CONDUIT FROM

TELECOMM OUTLET LOCATIONS TO THE CABLE TRAY.

9. ALL HORIZONTAL AND BACKBONE CABLING SHALL BE PLENUM RATED WITH THE EXCEPTION OF

CABLING INSTALLED IN UNDERGROUND CONDUITS. SEE NOTE 23 FOR CABLES INSTALLED IN

UNDERGROUND CONDUITS.

10. CAT 6 CABLING SHALL BE TERMINATED ON 8-PIN, 8-CONDUCTOR (RJ-45) CONNECTORS USING

PIN/PAIR ASSIGNMENTS IN ACCORDANCE WITH T568A PIN-OUT SEQUENCE.

11. CAT 6 JACKS SHALL BE THE SAME COLOR AS CORRESPONDING HORIZONTAL CABLING. CAT 6

JACKS SHALL BE THE SAME MANUFACTURER AS THE PATCH PANELS.

12. PROVIDE CAT 6, 8-PIN, 8-CONDUCTOR MODULAR TO 8-PIN, 8-CONDUCTOR MODULAR, PATCH

CABLES IN QUANTITIES AND LENGTHS SUCH THAT ALL WORKSTATION CABLES ARE CONNECTED.

13. PROVIDE CAT 6, 8-PIN, 8-CONDUCTOR MODULAR TO 1-PAIR 110 CLIP, PATCH CABLES IN QUANTITIES

AND LENGTHS FOR CONNECTION FROM PATCH PANELS TO RACK MOUNTED 110 BLOCKS.

14. OPTICAL FIBER CABLES SHALL BE TERMINATED WITH DUPLEX SC-TYPE CONNECTORS.

15. THE USE OF J-HOOKS SHALL BE LIMITED. WHEN USED, J-HOOKS SHALL BE CAT 6 RATED AND SPACES AT INTERVALS NOT TO EXCEED 1.5M. J-HOOKS SHALL NOT EXCEED 24 CABLES OR 50%

FILL, WHICHEVER IS LESS. WHEN J-HOOKS ARE USED TO SPAN FROM CONDUIT STUB UPS TO

CABLE TRAY A BONDING BUSHING SHALL BE INSTALLED ON THE CONDUIT STUB UPS AND A

MINIMUM 16mm SQ. GROUND CONDUCTOR SHALL BE INSTALLED FROM THE BONDING BUSHING TO

THE CABLE TRAY, EFFECTIVELY BONDING THE METALLIC RACEWAYS TOGETHER.

16. ALL TELECOMMUNICATIONS RACKS AND SUPPORTING STRUCTURES (CABLE TRAYS, LADDER

RACKS, CONDUITS, AND BASKETS) WITHIN A TR MUST BE BONDED TO THE TR SIGNAL GROUND

RING OR BUS BAR (TGB OR TMGB) AS DEFINED IN ANSI/TIA-569-C AND IN ANSI/TIA-607-B.

17. CABLE TRAY SHALL BE WALL MOUNTED (PREFERABLE) OR TRAPEZE MOUNTED. CENTER HUNG

CABLE TRAY IS NOT ALLOWED. CABLE TRAY SHALL NOT BE USED TO SUPPORT OTHER ITEMS,

CONDUIT, CABLE TRAY, PIPING OF UTILITIES. CLASSIFIED CABLE TRAYS (SIPR & JWICS) MUST BE

ELECTRICALLY ISOLATED FROM AND CANNOT BE SUPPORTED BY THE SAME SUPPORT STRUCTURE

AS THE BLACK (NIPR) CABLE TRAY. CABLE TRAY SUPPORTS SHALL BE PER NEMA STANDARDS

PUBLICATION VE 2 - METAL CABLE TRAY INSTALLATION GUIDELINES.

18. PROVIDE ACCESS PANELS IN NON LAY-IN CEILINGS SUCH THAT NO POINT IN THE CABLE TRAY SYSTEM IS MORE THAN 6m FROM AN ACCESS POINT.

19. PROVIDE A MINIMUM OF 305mm OF CLEARANCE ABOVE THE TOP OF CABLE TRAYS AND A MINIMUM OF 76mm CLEARANCE BELOW CABLE TRAYS.

20. PROVIDE RECTANGULAR, MODULAR, FIRE RATED WALL PENETRATION ASSEMBLIES USING EITHER

INTEGRAL, SLIDING COVERS OR REMOVABLE PLUGS.

21. COMPLY WITH TIA/EIA-569-C TELECOMMUNICATION PATHWAYS AND SPACES.

22. USE ONLY COPPER CONDUCTORS FOR GROUND CONNECTIONS. THE USE OF ALUMINUM

CONDUCTORS IS NOT ALLOWED.

23. PROVIDE CABLE INSTALLED IN UNDERGROUND CONDUITS LISTED FOR USE IN WET LOCATIONS.

PLENUM RATED CABLE SHALL NOT BE INSTALLED IN ANY UNDERGROUND CONDUIT.

24. PROVIDE OSP CABLES RATED FOR OUTDOOR USE, FILLED WITH A WATER BLOCKING COMPOUND.

25. LABEL ALL CABLE TERMINATIONS AND BOTH ENDS OF ALL CABLES IN ACCORDANCE WITH UFC

3-580-01 AND ANSI/TIA-606-B.

26. PROVIDE AS-BUILT DOCUMENTATION INCLUDING COMPLETE TEST RESULT REPORTS, FLOOR

PLANS SHOWING USER WORKSTATIONS WITH CABLING LABELING, AND BACKBONE CABLE

SCHEMATIC AND LABELING IN AN ELECTRONIC FORMAT (PDF) OR OTHER APPROVED FORMAT AND

A PRINTED HARDCOPY. TEST RESULTS SHALL BE SUPPLIED ELECTRONICALLY TO THE PROJECT

RCDD AND CORPS PROJECT ENGINEER/ARCHITECT IN THE TEST PROGRAM NATIVE FORMAT.

27. PROVIDE ALL REQUIRED AMPLIFIERS, MULTIPORT TAPS, SPLITTERS, OUTLETS AND F TYPE

CONNECTORS FOR A COMPLETE AND USABLE CATV SYSTEM.

28. ANY MOTOR, TRANSFORMER, OR OTHER ELECTRICAL DEVICE GREATER THAN 5 KVA SHALL HAVE A

MINIMUM OF A 1.2M BUFFER FROM ANY WALL OF THE EF, TER, OR TR(S).

29. CLOSED-CIRCUIT TELEVISION (CCTV) SYSTEM INFRASTRUCTURE TO INCLUDE 27mm CONDUIT WITH PULL WIRE INSTALLED FROM IP65 (NEMA 4) COMMUNICATIONS DEVICE JUNCTION BOXES RUN BACK

TO DESIGNATED SECURITY MONITOR LOCATION INSIDE THE BUILDING.

30. PROVIDE COMMUNICATIONS FACEPLATES THAT MATCH ELECTRICAL FACEPLATES. FOR STANDARD ADMINISTRATIVE OUTLETS USE A FULL OUTLET FACE PLATE WITH LOCATIONS FOR ALL COPPER

CABLE JACKS/CONNECTORS/BLANKS. FOR SINGLE GANG OUTLET BOXES, USE A SINGLE GANG

OUTLET PLATE WITH THE PROPER JACKS/CONNECTORS/BLANKS, AND IF REQUIRED, MOUNTING

LUGS FOR ALL PHONES. FACEPLATES NOT FOR USE AS WALL-MOUNTED PHONE OUTLETS SHALL

BE AT A MINIMUM FOUR (4) PORT HAVING A MINIMUM OF TWO (2) SPARE PORTS FILLED WITH BLANK

PORT INSERTS.

31. PULL BOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A CONTINUOUS CONDUIT LENGTH

EXCEEDS 30.5M, OR WHERE THERE ARE MORE THAN TWO 90-DEGREE BENDS. PULL BOXES SHALL BE PLACED IN STRAIGHT, ALIGNED RUNS OF CONDUIT AND NOT BE USED IN LIEU OF A BEND.

32. EQUIPMENT (PIPING, DUCTWORK, MACHINERY, ETC.) THAT DOES NOT SERVE THE EF, TER, OR TR(S) SHALL NOT BE INSTALLED ABOVE OR IN THESE IT SPACES, NOR WILL THIS EQUIPMENT PASS

THROUGH OR ENTER THE EF, TER, OR TR(S).

33. PROVIDE TWO (2) 35mm TELECOMMUNICATIONS CONDUITS FROM FLOOR BOX TO TRANSITION

POINT ABOVE CEILING.

8P8C

ACS

AFF

BCT

C

CAA

CAT 6

CATV

CCTV

CFCI

CP

DB

DIA

DWG

ER

ESS

ETR

EXIST

FB

GFGI

GND

GRS

IAW

ICT

IDS

IP

LCA

MC

MIN

MM

MTD

NEC

NEMA

NESC

NFPA

NIC

NTS

OEM

OFCI

OFOI

ONVIF

OSHA

PA

PBB

PE

PET

POTS

PSI

PTZ

QTY

RR

RS

RU

SBB

SCH

TBB

TGB

TMGB

TYP

U/FTP

U/G

UON

U/UTP

WP

XP

110 PUNCHDOWN BLOCKS, RACK OR WALL MOUNTED AS INDICATED

/ 110 BLOCCHI RIBATTUTI, RACK O MONTAGGIO A PARETE, COME

INDICATO

8 PIN CONNECTOR / A 8 PIN, 8 CONDUTTORI

ACCESS CONTROL SYSTEM / ACS SISTEMA DI CONTROLLO D'ACCESSO

ABOVE FINISHED FLOOR / SOPRA AL PAVIMENTO FINITO

BONDING CONDUCTOR FOR TELECOMMUNICATIONS

CONDUIT(S) / CONDOTTA/E

CONTROLLED ACCESS AREA / AREA AD ACCESSO CONTROLLATO

CABLING ETL VERIFIED TO TIA/EIA-568-C.2 CATEGORY 6 / CABLAGGIO

VERIFICATION ETL PER TIA/EIA-568-C.2 CATEGORIA 6

CABLE TELEVISION / TELEVISIONE VIA CAVO

CLOSED-CIRCUIT TELEVISION / TELECIVISIONE A CIRCURITO CHIUSO

CONTRACTOR FURNISHED CONTRACTOR INSTALLED / AMMOBILIATO

DALL' APPALTATORE

CONSOLIDATION POINT / PUNTO DI CONSOLIDAMENTO

DIRECT BURIED / INTERRATO DIRETTO

DIAMETER / DIAMETRO

DRAWING / DISEGNO

EXISTING RELOCATED / RIPOSIZONATO ESISITENETE

ELECTRONIC SAFETY AND SECURITY / SICUREZZA ELETTRONICA

EXISTING TO REMAIN / ESISTENTE DA PRESERVARE

EXISTING / PREESISTENTE

FLOOR BOX / SCATOLA A PAVIMENTO

GOVERNMENT FURNISHED GOVERNMENT INSTALLED / AMMOBILIATIO

DAL GOVERNO INSTALLATIO DAL GOVERNO

GROUND / TERRA

GALVANIZED RIGID STEEL / ACCIAIO RIGIDO ZINCATO

IN ACCORDANCE WITH / IN CONFORMITA CON

INFORMATION AND COMMUNICATIONS TECHNOLOGY / TECNOLOGICA

DELLE COMUNICAZIONI DELL INFORMAZIONE

INTRUSION DETECTION SYSTEM / SISTEMA DI RILEVAMENTO DELLE

INTUSIONI

INTERNET PROTOCOL / PROTOCOLLO INTERNET

LIMITED CONTROL ACCESS / ACCESSO A CONTROLLO LIMITATO

MECHANICAL CONTRACTOR / APPALTATORE MECCANICO

MINIMUM / MINIMO

MILLIMETER / MILLIMETRO

MOUNTED / MONTATO

NETWORK ENTERPRISE CENTER / CENTRO IMPRESA DI RETE

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION /

ASSOCIAZIONE NAZIONALE DEI PRODUTTORI DEL SETTORE ELETRICO

NATIONAL ELECTRICAL SAFETY CODE / CODICE NAZIONALE DI

SICUREZZA ELETTRICA

NATIONAL FIRE PROTECTION ASSOCIATION / ASSOCIAZIONE

NAZIONALE PROTEZIONE ANTINCENDIO

NOT IN CONTRACT / ECLUSO DALL'APPALTO

NOT TO SCALE / NON IN SCALA

ORIGINAL EQUIPMENT MANUFACTURER / PRODUTTORE ATTREZATURE

ORIGINALE

OWNER FURNISHED CONTRACTOR INSTALLED / AMMBILIATO DAL

PROPRIETTARIO INSTALLATIO DALL'APPALTATORE

OWNER FURNISHED OWNER INSTALLED / AMMOBILIATO DAL

PROPIETARIOI INSTALLATO DAL PROPRIETARIO

OPEN NETWORK VIDEO INTERFACE FORUM / FORUM INTEFACCIA

VIDEO DI RETE APERTA

OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION /

AMMINISTAZIONE PER LA SALUTE E LA SICUREZZA DEL LAVORO

PUBLIC ADDRESS / INDIRIZZO PUBBLICO

PRIMARY BUSBAR /

POLYETHYLENE / POLIETILENE

PROTECTED ENTRANCE TERMINALS / TERMINALI A INGRESSO

PROTETTO

PLAIN OLD TELEPHONE SERVICE

(SWITCHED TELEPHONE LINE) / LINEA TELEFONICA COMMUTATA

POUNDS PER SQUARE INCH / LIBBRE PER POLLICE QUADRATO

PAN / TILT / ZOOM

QUANTITY / QUANTITI

REMOVE AND RELOCATE / RIMUOVERE RIPOSIZIONARE

RIGID STEEL / ACCIAIO RIGIDO

RACK UNIT / RACK UNIT

SECONDARY BUSBAR /

SCHEDULE / PROGRAMMA

TELECOMMUNICATIONS BONDING BACKBONE / DORSALE DI UNIONE

DELLE TELECOMUNICAZIONI

TELECOMMUNICATIONS GROUNDING BUSBAR / BLINDOSBARRA DI

MESSA A TERRA DELLE TELECOMUNICAZONI

TELECOMMUNICATIONS MAIN GROUNDING BUSBAR / BLINDOSBARRA

DI MESSA A TERRA PRINCIPALE DELLE TELECOMMUNICAZIONI

TYPICAL / TIPICO

UNSCREENED FOIL-SCREENED TWISTED-PAIR

(INDIVIDUALLY FOIL- SCREENED TWISTED - PAIR) / DOPPINO

SCHEAMATO A FOGLIO NON SCHERMATO

UNDERGROUND / SOTTERRANEO

UNLESS OTHERWISE NOTED / SE NON DIVERSAMENTE INDICATO

OVERALL UNSHIELDED TWISTED - PAIR WITH

UNSHIELDED TWISTED - PAIR / DOPPINO COMPLESSIVAMENTE NON

SCHERMATO

WEATHERPROOF / IMPERMEABILE

EXPLOSION PROOF / ANTIDEFLAGRANTE

STANDARD WORK AREA OUTLET (WAO), CLASSIFIED; TWO (2) CATEGORY 6 F/UTP 4-PAIR

COPPER CABLES, WITH OVERALL RED JACKET, INSTALLED ON TWO-PORT FACEPLATE AT

DEVICE LOCATION, MOUNTED AT 460" AFF

DIRECT DATA CONNECTION; TWO (2) CATEGORY 6 UTP 4-PAIR COPPER CABLES, WITH

OVERALL GREEN JACKET, INSTALLED ON TWO-PORT FACEPLATE AT DEVICE LOCATION;

WITH MOUNTING HEIGHT COORDINATED WITH EQUIPMENT AT TERMINATION LOCATION

TELEVISION CONNECTION; TWO (2) CATEGORY 6 UTP 4-PAIR COPPER CABLES, WITH

OVERALL GREEN JACKET AND ONE (1) RG-6 QUAD SHIELD COAXIAL CABLE, INSTALLED ON

FOUR-PORT FACEPLATE AT DEVICE LOCATION, MOUNTED AT 1830" AFF UNLESS

OTHERWISE NOTED

TV

DDC

S

CEILING-MOUNTING PASSIVE INFRARED SENSOR (PIR) / SENSORE

INFRAROSSI PASSIVO (PIR) A SOFFITTO

STANDARD WORK AREA OUTLET (WAO), UNCLASSIFIED FLOORBOX; TWO (2) CATEGORY 6

UTP 4-PAIR COPPER CABLES, WITH OVERALL GREEN JACKET, INSTALLED ON TWO-PORT

FACEPLATE AT DEVICE LOCATION, MOUNTED IN FLOORBOX. COORDINATE FLOORBOX

LOCATION, PLACEMENT AND INSTALLATION WITH OTHER TRADES.

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A S

E

A V

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F

A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

R

IM

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-T

.r v t

/6

/2

:0

:5

P M

T E

L E

C O

M M

U N

IC

A

T

IO

N S

N

O T

E S

S

Y M

B O

L S

A

B B

R E

V

IA

T

IO

N

JMGETHJTE

T-001

T E

L E

C O

M U

N

IC

A Z

IO

N

I

N O

T E

S

IM

B

O L

I E

A B

B R

E V

IA

Z

IO

N

I

14125582

SEK

Approved by CDR Jonathan Horner, ROICC, via SAT-TO form

SIMBOLO PIANO DELLE TELECOMUNICAZIONI

LE PRESE A PARETE DELLA ZONA DI LAVORO (WAO) DEVONO ESSERE INSTALLATE CON UNA CANALINA MIN 1-1/4” / 3CM DAL SOFFITTO (O DAL PIANO D'ACCESSO RIALZATO) ACCESSIBILE ALLA CASSETTA DI DERIVAZIONE QUADRATA, MONTATA A FILO DEL MURO DA 5”/13CM, DOTATA DI ANELLO RIDUTTORE

SINGOLO CON CORDICELLA.

LE TERMINAZIONI T568A DEVONO ESSERE REALIZZATE UTILIZZANDO MODULI CONNETTORE DI TIPO KEYSTONE 8P8C RJ45 ADATTI ALLA CATEGORIA DEL CAVO INSTALLATO. TUTTI I CABLAGGI DEVONO ESSERE CLASSIFICATI UL PER L’AMBIENTE NEL QUALE SONO INSTALLATI: SOVRAPRESSIONE, COLONNA

O SENZA CLASSIFICAZIONE PER CABLAGGI OSP.

PRESA STANDARD PER LA ZONA DI LAVORO (WAO), NON CLASSIFICATA; DUE (2) CAVI IN RAME A

4 COPPIE CATEGORIA 6 UTP, CON GUAINA VERDE, INSTALLATI SU MASCHERINA A DUE PORTE

ALLA POSTAZIONE DEL DISPOSITIVO, MONTATA A 18”/45CM SUL LIVELLO DEL PAVIMENTO

FINITO.

PRESA STANDARD PER LA ZONA DI LAVORO (WAO), CLASSIFICATA; DUE (2) CAVI IN RAME A 4

COPPIE CATEGORIA 6 UTP, NON CLASSIFICATI, CON GUAINA ROSSA, INSTALLATI SU

MASCHERINA A DUE PORTE ALLA POSTAZIONE DEL DISPOSITIVO, MONTATA A 18”/45CM SUL

LIVELLO DEL PAVIMENTO FINITO.

CONNESSIONE DATI DIRETTA; DUE (2) CAVI IN RAME A 4 COPPIE CATEGORIA 6 UTP, CON GUAINA

VERDE, INSTALLATI SU MASCHERINA A DUE PORTE ALLA POSTAZIONE DEL DISPOSITIVO;

ALTEZZA DI MONTAGGIO DIPENDENTE DALLE APPARECCHIATURE NELLA POSIZIONE DELLA

TERMINAZIONE

COLLEGAMENTO TELEVISIONE; DUE (2) CAVI IN RAME A 4 COPPIE CATEGORIA 6 UTP, CON

GUAINA VERDE, E UN (1) CAVO COASSIALE SCHERMO QUADRUPLO RG-6, INSTALLATO SU

MASCHERINA A QUATTRO PORTE ALLA POSIZIONE DEL DISPOSITIVO, MONTATA A 72”/183CM SUL

LIVELLO DEL PAVIMENTO FINITO, SE NON DIVERSAMENTE SPECIFICATO

PRESA PER LA ZONA DI LAVORO (WAO), VUOTA; UNA (1) CASSETTA DI DERIVAZIONE QUADRATA

DA 5”/13CM MONTATA A FILO DEL MURO, CON ANELLO RIDUTTORE SINGOLO, E MASCHERINA

CIECA, MONTATA A 18”/45CM SUL LIVELLO DEL PAVIMENTO FINITO

PRESA STANDARD PER LA ZONA DI LAVORO (WAO), CASSETTA A PAVIMENTO NON

CLASSIFICATA; DUE (2) CAVI IN RAME A 4 COPPIE CATEGORIA 6 UTP, CON GUAINA VERDE,

INSTALLATI SU MASCHERINA A DUE PORTE ALLA POSTAZIONE DEL DISPOSITIVO, MONTATA

NELLA CASSETTA A PAVIMENTO. COORDINARE LA POSIZIONE E L’INSTALLAZIONE DELLA

CASSETTA A PAVIMENTO CON GLI ALTRI SOGGETTI.

NORMATIVE PER LE TELECOMUNICAZIONI NOTE GENERALI SULLE TELECOMUNICAZIONI

AR 380-40 - SALVAGUARDIA E CONTROLLO DEL MATERIALE DI SICUREZZA DELLE COMUNICAZIONI

CNSSAM TEMPEST/1-13 - (U) RED/BLACK INSTALLATION GUIDANCE

CNSSI 7003 SISTEMI DI DISTRIBUZIONE PROTETTI (PDS)

USASOC REG 380-40 SISTEMA DI DISTRIBUZIONE PROTETTO (PDS) PER LA SICUREZZA DELLE

COMUNICAZIONI (COMMSEC)

USGS 27 05 29.00 10 SISTEMA DI DISTRIBUZIONE PROTETTO (PDS) PER I SISTEMI DI COMUNICAZIONI

SIPRNET

NSTISSI NO. 7003 SISTEMI DI DISTRIBUZIONE PROTETTI (PDS)

GUIDA ALLA PROGETTAZIONE TECNICA DELLA TECNOLOGIA DELL’INFORMAZIONE (IT) USASOC

CRITERI TECNICI DI APPLICAZIONE DELLA RETE ROUTER PROTOCOLLO INTERNET SEGRETO (SIPRNET)

DODD 8100.02 - (U) USO DI TECNOLOGIE, SERVIZI E DISPOSITIVI WIRELESS NELLA GLOBAL

INFORMATION GRID (GIG) DEL DIPARTIMENTO DELLA DIFESA (DOD)

MIL-HDBK-419A: MESSA A TERRA, COLLEGAMENTO E SCHERMATURA PER STRUTTURE E

APPARECCHIATURE ELETTRONICHE

MIL-STD-188-124B (U) MESSA A TERRA, COLLEGAMENTO E SCHERMATURA PER SISTEMI DI

COMUNICAZIONE TATTICI/A LUNGO RAGGIO, COMPRESE LE STRUTTURE ELETTRONICHE DI

COMUNICAZIONE A TERRA PER LE APPARECCHIATURE

RUS BULLETIN 1751F-640, PROGETTAZIONE DEGLI IMPIANTI INTERRATI - CONSIDERAZIONI FISICHE

RUS BULLETIN 1751F-644, 2002 - COSTRUZIONE DEGLI IMPIANTI SOTTERRANEI

ICEA S-87-640, 2011 - CAVO DI COMUNICAZIONE ESTERNO ALL’IMPIANTO IN FIBRA OTTICA

ICEA S-98-688, 2012 - REQUISITI TECNICI PER CONDUTTORI IN RAME, ISOLATI CON POLIOLEFINA, DI

TIPO AIRCORE A DOPPINO PER BANDA LARGA

B

TV

DDC

S

L’INSTALLAZIONE DELLE TELECOMUNICAZIONI DEV’ESSERE REALIZZATA NEL RISPETTO DELLA VERSIONE

PIÙ RECENTE DELLE NORMATIVE SEGUENTI:

I3A - CRITERI TECNICI PER L’INSTALLAZIONE DELL’ARCHITETTURA DELL’INFRASTRUTTURA INFORMATICA

REQUISITI DI PRESTAZIONE E PROGETTAZIONE DEGLI IMPIANTI ESTERNI (OSPDPR)

ANSI/TIA-568.0-D: CABLAGGI PER TELECOMUNICAZIONI GENERICHE PER LA SEDE DEL CLIENTE

ANSI/TIA-568.1-D: NORME PER I CABLAGGI PER TELECOMUNICAZIONI NEGLI EDIFICI COMMERCIALI

TIA/EIA-569-C: SPAZIO E PERCORSI DELLE TELECOMUNICAZIONI

TIA/EIA-568-C.0: CABLAGGI GENERICI PER TELECOMUNICAZIONI NEGLI EDIFICI DEL CLIENTE

TIA/EIA-568-C.1: NORME PER I CABLAGGI PER TELECOMUNICAZIONI NEGLI EDIFICI COMMERCIALI

ANSI/TIA-568-C.2: NORME SU COMPONENTI E CABLAGGI PER TELECOMUNICAZIONI CON DOPPINI

BILANCIATI

ANSI/TIA-568.3-D: NORME SUI COMPONENTI DI CABLAGGI IN FIBRA OTTICA

ANSI/TIA-568.4-D: NORME SUI COMPONENTI E I CABLAGGI COASSIALI BANDA LARGA

ANSI/TIA-569-C, 2012: SPAZI E PERCORSI DELLE TELECOMUNICAZIONI

ANSI/TIA-606-B: NORMA AMMINISTRATIVA PER L’INFRASTRUTTURA DELLE TELECOMUNICAZIONI

COMMERCIALI

TIA-526-7 (OFSTP-7)-2002+A1:2008: MISURAZIONE DELLA PERDITA DI POTENZA OTTICA DI UN IMPIANTO A

FIBRA MONOMODALE

ANSI/TIA-607-B, 2011: REQUISITI DI COLLEGAMENTO E MESSA A TERRA DEGLI EDIFICI COMMERCIALI PER LE

TELECOMUNICAZIONI

ANSI/TIA-1152, 2009: REQUISITI PER LE MISURAZIONE E GLI STRUMENTI DI TEST SUL CAMPO PER I

CABLAGGI A DOPPINI BILANCIATI

ANSI/TIA-942A: NORME PER L’INFRASTRUTTURA DI TELECOMUNICAZIONE PER I CENTRI DATI

TIA TSB-162-A, 2013: LINEE GUIDA PER I CABLAGGI DELLE TELECOMUNICAZIONI PER I PUNTI DI ACCESSO

WIRELESS

ANSI/NECA/BICSI 568: NORME PER L’INSTALLAZIONE DEI CABLAGGI DI TELECOMUNICAZIONE NEGLI EDIFICI

COMMERCIALI

NFPA 70: NORMATIVA ELETTRICA NAZIONALE (NEC)

NFPA 75: NORMATIVA PER I DISPOSITIVI DI TECNOLOGIA INFORMATICA DI PROTEZIONE ANTINCENDIO

NFPA 76: NORMATIVA PER LA PROTEZIONE ANTINCENDIO DELLE INFRASTRUTTURE DI

TELECOMUNICAZIONE

MIL-HDBK-232A : RED/BLACK ENGINEERING-INSTALLATION GUIDELINES

TM 5-853-4 MANUALE TECNICO DEI SISTEMI DI SICUREZZA ELETTRONICI DEL CORPO DEI GENIERI

IC-TECH SPEC ICD/ICS 705, ICS-705-1, ICS-705-2

COSC ISP NORME DI INSTALLAZIONE VERSIONE 1.0, 16 MAGGIO 2011

CRITERI TECNICI SIPRNET: CRITERI TECNICI DI APPLICAZIONE RETE ROUTER PROTOCOLLO INTERNET

SEGRETO (SIPRNET)

UFC 4-020-04A : SISTEMI DI SICUREZZA ELETTRONICI: INGEGNERIA DELLA SICUREZZA

UFC 4-010-05: PIANIFICAZIONE, PROGETTAZIONE E COSTRUZIONE DI STRUTTURE COMPARTIMENTATE DI

INFORMAZIONI SENSIBILI

UFC 3-580-01: PIANIFICAZIONE E PROGETTAZIONE DI SISTEMI DI CABLAGGIO NEGLI EDIFICI PER

TELECOMUNICAZIONI

UFC 4-020-04A : SISTEMI DI SICUREZZA ELETTRONICI: INGEGNERIA DELLA SICUREZZA

MIL-HDBK-1012/3: PIANIFICAZIONE, PROGETTAZIONE E STIMA DELLA DISTRIBUZIONE DELLE STRUTTURE DI

TELECOMUNICAZIONE

GUIDA TECNICA IT USASOC

AR 380-5 - PROGRAMMA DI SICUREZZA DELLE INFORMAZIONI DEL DIPARTIMENTO DELL'ESERCITO

AR 380-27 - (FOUO) CONTROLLO DELLE EMANAZIONI COMPROMETTENTI

1. SI TRATTA DI UNA LEGENDA STANDARD. NON TUTTI I SIMBOLI O LE ABBREVIAZIONI SONO PRESENTI

NEI DISEGNI.

2. FARE RIFERIMENTO ALLE DIVISIONI 26, 27, 28 E SPECIFICHE 33 PER I COMPONENTI DEI SISTEMI DI

TELECOMUNICAZIONE.

3. MONTARE DISPOSITIVI E APPARECCHIATURE COME DA SPECIFICHE, SALVO DIVERSAMENTE

INDICATO.

4. LE ALTEZZE DI MONTAGGIO, SE NON DIVERSAMENTE INDICATO, SONO ALLA LINEA MEDIANA DEL

DISPOSITIVO.

5. L’APPALTATORE DEVE DEFINIRE IL PERCORSO PRECISO DELLE CANALETTE.

6. L’APPALTATORE DEVE COORDINARE TUTTE LE PENETRAZIONI PER CANALETTE E RENDERLE

IGNIFUGHE, LADDOVE APPLICABILE.

7. LA DISTANZA DI COLLEGAMENTO ORIZZONTALE PERMANENTE MASSIMA DEV'ESSERE DI 90M E IL

CANALE ORIZZONTALE MASSIMO (COLLEGAMENTO, CAVI DELLA POSTAZIONE DI LAVORO E CAVI

PATCH) DEV'ESSERE DI 100M.

8. TUTTI I CABLAGGI ORIZZONTALI DATI E VOCE DEVONO ESSERE DI CATEGORIA 6 E INSTALLATI IN

UNA CONDOTTA DI ALMENO 41MM DALLE PRESE PER LE TELECOMUNICAZIONI ALLA PASSERELLA

PORTA-CAVI.

9. TUTTI I CABLAGGI DI DORSALE E ORIZZONTALI DEVONO AVERE CLASSIFICAZIONE PER

SOVRAPRESSIONE, AD ECCEZIONE DEI CABLAGGI INSTALLATI NELLE CONDOTTE SOTTERRANEE.

VEDI NOTA 23 PER I CAVI INSTALLATI NELLE CONDOTTE SOTTERRANEE.

10. I CABLAGGI DI CATEGORIA 6 DEVONO TERMINARE CON CONNETTORI A 8 PIN, 8 CONDUTTORI (RJ-45) USANDO ASSEGNAZIONI PIN/COPPIA PREVISTE DALLA SEQUENZA DEI PIEDINI T568A.

11. I JACK DI CATEGORIA 6 DEVONO AVERE LO STESSO COLORE DEL CABLAGGIO ORIZZONTALE DATI E

VOCE CORRISPONDENTE. I JACK DI CATEGORIA 6 DEVONO PROVENIRE DALLO STESSO

PRODUTTORE DEI PANNELLI PATCH.

12. FORNIRE MODULARE 8 PIN, 8 CONDUTTORI DI CAT 6 A MODULARE 8 PIN, 8 CONDUTTORI, CAVI

PATCH IN QUANTITÀ E LUNGHEZZA TALI DA COLLEGARE I CAVI DI TUTTE LE POSTAZIONI DI

LAVORO.

13. FORNIRE MODULARE 8 PIN, 8 CONDUTTORI DI CAT 6 A CLIP 100 A 1 COPPIA, CAVI PATCH NELLE

QUANTITÀ E LUNGHEZZE NECESSARIE PER IL COLLEGAMENTO DAI PANNELLI PATCH VOCE AI

BLOCCHI 110 MONTATI SU RACK.

14. I CAVI IN FIBRA OTTICA DEVONO TERMINARE CON CONNETTORI DI TIPO SC DUPLEX.

15. L’USO DI GANCI A J DEV’ESSERE LIMITATO. SE UTILIZZATI, I GANCI A J DEVONO ESSERE DI CATEGORIA 6 E DISTANZIATI A NON PIÙ DI 1,5M. I GANCI A J NON DEVONO PORTARE PIÙ DI 24 CAVI O ESSERE RIEMPITI A PIÙ DEL 50%, LA QUANTITÀ INFERIORE TRA LE DUE. QUANDO I GANCI A J VENGONO IMPIEGATI PER IL PASSAGGIO DAL TRONCO DI LINEA ALLA PASSERELLA PORTA-CAVI, È NECESSARIO INSTALLARE UNA BOCCOLA SUL TRONCO DI LINEA E UN CONDUTTORE DI TERRA DA

16MM MINIMO DALLA BOCCOLA ALLA PASSERELLA, IN MODO DA COLLEGARE TRA LORO LE

CANALETTE METALLICHE.

16. TUTTI I RACK E LE STRUTTURE DI SUPPORTO PER LE TELECOMUNICAZIONI (PASSERELLA PORTA-

CAVI, RACK A SCALA, CONDOTTE E CONTENITORI) ALL’INTERNO DI UN TR DEVONO ESSERE

COLLEGATI ALLA BLINDOSBARRA O ALL’ANELLO DI TERRA DEL SEGNALE TR (TGB O TMGB), COME

DEFINITO IN ANSI/TIA-569-C E IN ANSI/TIA-607-B.

17. LA PASSERELLA PORTA-CAVI DEV’ESSERE (PREFERIBILMENTE) MONTATA A PARETE O SU

TRAPEZIO. LE PASSERELLE PORTA-CAVI SOSPESE NON SONO AMMESSE. LE PASSERELLE PORTA-

CAVI NON DEVONO ESSERE USATE PER SOSTENERE ALTRI OGGETTI, CONDOTTE, PASSERELLE,

TUBATURE O IMPIANTI PER SERVIZI. LE PASSERELLE PORTA-CAVI CLASSIFICATE (SIPR E JWICS)

DEVONO ESSERE ISOLATE ELETTRICAMENTE E NON POSSONO ESSERE SOSTENUTE DALLA

STESSA STRUTTURA DI SUPPORTO DELLA PASSERELLA PORTA-CAVI NERA (NIPR). I SUPPORTI

DELLA PASSERELLA PORTA-CAVI DEVONO RISPETTARE LA PUBBLICAZIONE VE 2 DELLE NORMATIVE

NEMA - LINEE GUIDA PER L’INSTALLAZIONE DI PASSERELLE PORTA-CAVI METALLICHE

18. PREVEDERE PANNELLI DI ACCESSO NEI SOFFITTI SOSPESI, IN MODO CHE NESSUN PUNTO DEL

SISTEMA DELLA PASSERELLA PORTA-CAVI SI TROVI A PIÙ DI 6 M DAL PUNTO DI ACCESSO.

19. PREVEDERE UN MINIMO DI 305MM DI SPAZIO AL DI SOPRA DELLE PASSERELLE PORTA-CAVI E UN

MINIMO DI 76MM DI SPAZIO AL DI SOTTO DELLE PASSERELLA PORTA-CAVI.

20. PREVEDERE UNITÀ DI PENETRAZIONE DELLE PARETI ANTINCENDIO, MODULARI E RETTANGOLARI

USANDO COPERCHI SCORREVOLI INTEGRALI O TAPPI REMOVIBILI.

21. RISPETTARE DISTANZE E PERCORSI PER LE TELECOMUNICAZIONI TIA/EIA-569-C.

22. UTILIZZARE ESCLUSIVAMENTE CONDUTTORI IN RAME PER I COLLEGAMENTI DI TERRA. L’USO DI

CONDUTTORI DI ALLUMINIO NON È CONSENTITO.

23. PREVEDERE UN CAVO INSTALLATO IN CONDOTTE SOTTERRANEE ADATTO ALL’USO IN AMBIENTI

UMIDI.

24. CAVI PER SOVRAPRESSIONE NON POSSONO ESSERE INSTALLATI ALL’INTERNO DELLE CONDOTTE

SOTTERRANEE.

25. PREVEDERE CAVI OSP PER L’USO IN AMBIENTE ESTERNO, RIEMPITI CON COMPOSTO

IDROREPELLENTE. ETICHETTARE TUTTE LE TERMINAZIONI DEI CAVI ED ENTRAMBE LE ESTREMITÀ

DI OGNI CAVO COME PREVISTO DALL’UFC 3-580-01 E ANSI/TIA-606-B.

26. FORNIRE DOCUMENTAZIONE AS-BUILT, COMPRESI REPORT COMPLETI SUI RISULTATI DEI TEST, PLANIMETRIE CHE MOSTRANO LE POSTAZIONI DI LAVORO DEGLI UTENTI CON ETICHETTATURA DEI

CABLAGGI E SCHEMA DEI CABLAGGI DELLA DORSALE ED ETICHETTATURA IN FORMATO

ELETTRONICO (PDF) O ALTRO FORMATO APPROVATO E UNA COPIA STAMPATA.

27. I RISULTATI DEI TEST DEVONO ESSERE FORNITI IN FORMATO ELETTRONICO AL RCDD DEL

PROGETTO E ALL’INGEGNERE/ARCHITETTO DI PROGETTO DEL CORPO NEL FORMATO NATIVO DEL

PROGRAMMA DI TEST. FORNIRE TUTTI GLI AMPLIFICATORI, PRESE MULTIPORTA, SDOPPIATORI, PRESE E CONNETTORI DI TIPO F PER CREARE UN SISTEMA CATV COMPLETO E UTILIZZABILE.

28. MOTORI, TRASFORMATORI O ALTRI DISPOSITIVI ELETTRICI DA PIÙ DI 5 KVA DEVONO ESSERE

POSIZIONATI A UNA DISTANZA MINIMA DI 1,2M DA TUTTE LE PARETI DI EF, TER O TR.

29. L’INFRASTRUTTURA DEL SISTEMA DI TELEVISIONE A CIRCUITO CHIUSO (CCTV) DEVE INCLUDERE

UNA CONDOTTA DA 27 MM CON FUNE INSTALLATA DALLE CASSETTE DI DERIVAZIONE DEL

DISPOSITIVO DELLE COMUNICAZIONI IP65 (NEMA 4) FINO AL MONITOR DI SICUREZZA DESIGNATO

UBICATO ALL’INTERNO DELL’EDIFICIO.

30. FORNIRE MASCHERINE PER LE COMUNICAZIONI ABBINATE A QUELLE ELETTRICHE. PER LE PRESE

AMMINISTRATIVE STANDARD, USARE UNA MASCHERINA COMPLETA CON LO SPAZIO PER TUTTI I

JACK/CONNETTORI/VUOTI E CAVI IN RAME. PER LE CASSETTE CON PRESA SINGOLA, USARE UNA

MASCHERINA CON PRESA SINGOLA E JACK/CONNETTORI/VUOTI ADEGUATI E, SE NECESSARIO,

STAFFETTE DI MONTAGGIO PER TUTTI I TELEFONI. LE MASCHERINE CHE NON VERRANNO

UTILIZZATE COME PRESE A MURO PER I TELEFONI DOVRANNO AVERE ALMENO QUATTRO (4)

PORTE CON ALMENO DUE (2) PORTE DI RISERVA CON ALL’INTERNO INSERTI VUOTI PER PORTE.

31. LE CASSETTE DEVONO ESSERE POSIZIONATE LUNGO CONDOTTE IN CUI LA LUNGHEZZA DELLA CONDOTTA CONTINUA SUPERA I 30,5M, OPPURE DOVE SONO PRESENTI PIÙ DI DUE CURVE A 90°. LE

CASSETTE DEVONO ESSERE POSIZIONATE LUNGO CONDOTTE DRITTE E ALLINEATE E NON

DEVONO ESSERE USATE AL POSTO DI UNA CURVA.

32. LE ATTREZZATURE (TUBATURE, CONDOTTE, MACCHINARI, ECC.) CHE NON SERVONO EF, TER O TR

NON DEVONO ESSERE INSTALLATE AL DI SOPRA O ALL’INTERNO DI QUESTI SPAZI IT E NON

DEVONO ATTRAVERSARE, NÉ ENTRARE IN EF, TER O TR.

33. FORNIRE DUE (2) CONDOTTE PER TELECOMUNICAZIONI DA 35MM DALLA CASSETTA A PAVIMENTO

AL PUNTO DI TRANSIZIONE AL DI SOPRA DEL SOFFITTO.

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F

A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-T

.r v t

/6

/2

:0

:5

P M

T E

L E

C O

M M

U N

IC

A

T

IO

N S

N

O T

E S

S

Y M

B O

L S

A

B B

R E

V

IA

T

IO

N

T-002

T E

L E

C O

M U

N

IC

A Z

IO

N

I

N O

T E

S

IM

B

O L

I E

A B

B R

E V

IA

Z

IO

N

I

14125583

SEK

Cux CuxCux Cux

C ux

C ux

Cux

CuxC ux

C ux

C ux

C ux

C ux

Cux Cux

Cux

Cux

Cux

Cux

Cux

Cux

Cux

Cux

Cux

Cux

Cux

C ux

Cu

CuCu Cu Cu

Cux

C u

C u

HH-7300-2

(EXISTING) / (ESISTENTE)

CHH

(EXISTING) /

(ESISTENTE)

HH-7300-1

(EXISTING) / (ESISTENTE)

CHH

(EXISTING) / (ESISTENTE)

CHH

(EXISTING) / (ESISTENTE)

HH-7300-3

(EXISTING) / (ESISTENTE)

HH-7300-4

(EXISTING) / (ESISTENTE)

CHH

(EXISTING) / (ESISTENTE)

HH-NEW

/ (HH-

NUOVO)

HH-NEW /

(HH-NUOVO)

2 1

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F

A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-T

.r v t

/6

/2

:0

:0

P M

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S

IT

E

P L

A N

TS101

T E

L E

C O

M U

N

IC

A Z

IO

N

I

P

IA

N T

A D

E L

S

IT

O

14125584

SEK

SCALE:1:500

mmM

20 mmM 40 mmM

1 SEE SHEET T-001 FOR TELECOMMUNICATIONS NOTES, SYMBOLS, AND

ABBREVIATIONS. / VEDI SCHEDA T-001 PER LE NOTE DI

TELECOMUNICAZIONE, SIMBOLI E ABBREVIAZIONI.

SCALE:1 : 500 / SCALA 1:500

TELECOMMUNICATIONS - SITE PLAN / TELECOMUNICAZIONI - PIANTA DEL

SITO

GENERAL SHEET NOTES / NOTE GENERALI

# SHEET KEYNOTES / FOGLIO NOTE PRINCIPALI

1. TWO (2) 100mm PVC CONDUIT IN CONCRETE ENCASEMENT / DUE (2) CONDOTTE IN PVC DA 100mm IN INVOLUCRO DI CALCESTRUZZO

2. HANDHOLE, 2m X 3m X 2.2m HIGH / PORTELLO, 2m X 3m X H2,2m

DN

DN

S B

DDC

DDC

TV TV

S

TV

S B

S

BS

B

S

S

TV

TV

TV

TV

SS

S B

S B

S B

S B

S B

S B

1 2 3 4 52.8

K.3

H

H.8

J

J.4

J.8

J.9

H.7

K

SIMULATOR

SERVER ROOM / AHU

VESTIBULE / VESTIBOLO

EQUIPMENT ROOM

DIRECTOR OPERATIONS

OFFICE

OPERATIONS SUP. OFFICE

TALO OFFICE

SCHEDULING AREA

EVALUATION AREA

MISSION PLANNING ROOM

MISSION BRIEFING ROOM

ARMORY

COMSEC

TEL / DATA

FLIGHT COMMANDER'S

OFFICE

LIBRARY / BIBLIOTECA

DUTY DESK

FLIGHT OPERATIONS

SUITE

MULTI-PURPOSE ROOM A /

SALA MULTIFUNZIONE A-1

072-1

MULTI-PURPOSE ROOM A /

SALA MULTIFUNZIONE A-2

072-2

MULTI-PURPOSE ROOM B /

SALA MULTIFUNZIONE B

SIMULATOR MX / TOOL

STORAGE / ICS SUPPORT /

SIMULATORE MX /

MAGAZZINO STRUMENTI /

SUPPORTO ICS

COMPUTER / IG /

COMPUTER /IG

CORRIDOR

VESTIBULE / VESTIBOLO

JAN / SERVIZIO

OFT SIMULATOR BAY /

BAIA SIMULATORE OFT

MECHANICAL /

MECCANICA-1

083-1

MECHANICAL /

MECCANICA-2

083-2BOILER / CALDAIA

SPARES STORAGE ROOM /

LOCALE STOCCAGGIO

RICAMBI

BOILER / CALDAIA

MECHANICAL /

MECCANICA-3

083-3

TELECOM / TELECOM

VESTIBULE / VESTIBOLO-1

067-1

MAINTENANCE OFFICE /

UFFICIO MANUTENZIONE

AVDTT / AVDTT

T-401 C1

MISSION PLANNING /

LIBRARY /

PIANIFICAZIONE MISSIONE

/ BIBLIOTECA

UNISEX LATRINE / SERVIZI

IGIENICI UNISEX

2 21 2

ELECTRICAL / ELETTRICA

C1 T-503

C1 T-503

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F

A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-T

.r v t

/6

/2

:0

:5

P M

T E

L E

C O

M M

U N

IC

A

T

IO

N S

F

IR

S

T F

L O

O R

P L

A

T-110

T E

L E

C O

M U

N

IC

A Z

IO

N

I

P

IA

N T

A P

R

IM

O P

IA

N

O

14125585

SEK

SCALE: 1 : 100 / SCALA 1:100

TELECOMMUNICATIONS - FIRST FLOOR PLAN / TELECOMUNICAZIONI - PLANIMETRIA PRIMO PIANO

A1 0

SCALE:1:100

2 mmM 4 mmM 8 mmM

1 SEE SHEET T-001 FOR TELECOMMUNICATIONS NOTES, SYMBOLS, AND

ABBREVIATIONS. / VEDI SCHEDA T-001 PER LE NOTE DI

TELECOMUNICAZIONE, SIMBOLI E ABBREVIAZIONI.

GENERAL SHEET NOTES / NOTE GENERALI

SHEET KEYNOTES / FOGLIO NOTE PRINCIPALI

1. 460mm X 100mm WIRE BASKET-STYLE CABLE TRAY, CLASSIFIED CABLING;

INSTALLED ABOVE FINISHED ACCESSIBLE CEILING, WITH 300mm MIN

CLEARANCE ABOVE AND ON EACH SIDE OF CABLE TRAY / PASSERELLA

PORTA-CAVI A CONTENITORE 460mm X 100mm, CABLAGGIO CLASSIFICATO, INSTALLATO AL DI SOPRA DEL SOFFITTO

FINITO ACCESSIBILE, CON UNA DISTANZA MIN DI 300mm AL DI SOPRA E SU

OGNI LATO DELLA PASSERELLA PORTA-CAVI.

2. 460mm X 100mm WIRE BASKET-STYLE CABLE TRAY, UNCLASSIFIED CABLING, INSTALLED ABOVE FINISHED ACCESSIBLE CEILING, WITH 300mm

MIN CLEARANCE ABOVE AND ON EACH SIDE OF CABLE TRAY / PASSERELLA

PORTA-CAVI A CONTENITORE 460mm X 100mm, CABLAGGIO

NON CLASSIFICATO, INSTALLATO AL DI SOPRA DEL SOFFITTO FINITO

ACCESSIBILE, CON UNA DISTANZA MIN DI 300mm AL DI SOPRA E SU OGNI

LATO DELLA PASSERELLA PORTA-CAVI.

3. GPS ANTENNA MOUNTED ON OFT SIMULATOR BAY EXTERIOR (SEE SHEET

T-503 FOR DETAILS) / ANTENNA GPS MONTATA SU BAIA SIMULATORE OFT

ESTERNO (VEDERE SCHEDA T-503 PER DETTAGLI).

4. EXTEND CABLE TRAY SYSTEM INTO COMM ROOM 044. COORDINATE

EXTENSION OF NEW CABLE TRAY SYSTEM WITH EXISTING CABLING

CONVEYANCES IN COMM ROOM 044 TO ENSURE PROPER SUPPORT FOR

INSTALLED CABLING / ESTENDERE IL CANALE PORTACAVI NELLA STANZA

COMUNICAZIONI 044. COORDINARE L'ESTENSIONE DEL NUOVO SISTEMA

DEL CANALE PASSACAVI CON I MEZZI DI PASSAGGIO DEI CAVI ESISTENTI

NELLA STANZA DI COMUNICAZIONE 044 PER GARANTIRE UN CORRETTO

SUPPORTO AL CABLAGGIO INSTALLATO.

2 ENSURE INSTALLED SEPARATION DISTANCE REQUIREMENTS BETWEEN

NIPRNET AND SIPRNET WORK AREA OUTLETS (WAOs) AND DESIGNATED

CABLE TRAY SYSTEMS PER CNSSAM TEMPEST/1-13 GUIDANCE. /

ASSICURARE I REQUISITI DI DISTANZA DI SEPARAZIONE INSTALLATI TRA

LE USCITE DELL'AREA DI LAVORO NIPRNET E SIPRNET (WAO) E I SISTEMI

DEL CANALE PORTACAVI DESIGNATI COME DALLA GUIDA CNSSAM

TEMPEST/1-13.

TEL / DATA

TELECOM / TELECOM

SIPR 1 (NEW) /

SIPR 1 (NUOVO)

SIPR 2 (NEW) /

SIPR 2 (NUOVO)

NIPR

(NEW) / NIPR

(NUOVO)

EXISTING

RACK / (RACK

ESISTENTE)

EXISTING

RACK / (RACK ESISTENTE)

ELEC (EXISTING) / (ELETT.) (ESISTENTE)

5 1

TELECOM EQUIPMENT

CABINET (600mm X 910mm X 2130mm)

/ (ARMADIETTO APPARECCHIATURE

DI TELECOMUNICAZIONE) (600mm X 910mm X 2130mm)

SPACE RESERVED

FOR CUSTOMER

EQUIPMENT / (SPAZIO

RISERVATO PER LE

APPARECCHIATURE DEL

CLIENTE)

FOPP - 48 LC

WIRE MGMT

48 PORT CAT6

WIRE MGMT

48 PORT CAT6

WIRE MGMT

48 PORT CAT6

WIRE MGMT

NIPRNET

CABINET

(NEW) / (ARMADIETTO NIPRNET)

(NUOVO)

TELECOM EQUIPMENT

CABINET (600mm X 910mm X 2130mm)

/ (ARMADIETTO APPARECCHIATURE

DI TELECOMUNICAZIONE) (600mm X 910mm X 2130mm)

SPACE RESERVED

FOR CUSTOMER

EQUIPMENT / (SPAZIO

RISERVATO PER LE

APPARECCHIATURE DEL

CLIENTE)

FOPP - 48 LC

WIRE MGMT

48 PORT CAT6

WIRE MGMT

48 PORT CAT6

WIRE MGMT

48 PORT CAT6

WIRE MGMT

SIPRNET 1

CABINET

(NEW) / (ARMADIETTO SIPRNET 1)

(NUOVO)

TELECOM EQUIPMENT

CABINET (600mm X 910mm X 2130mm) /

(ARMADIETTO APPARECCHIATURE DI

TELECOMUNICAZIONE) (600mm X 910mm X 2130mm)

SPACE RESERVED

FOR CUSTOMER

EQUIPMENT / (SPAZIO

RISERVATO PER LE

APPARECCHIATURE DEL

CLIENTE)

FOPP - 48 LC

WIRE MGMT

SIPRNET 2

CABINET

(NEW) / (ARMADIETTO SIPRNET 2)

(NUOVO)

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F

A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-T

.r v t

/6

/2

:0

:5

P M

T E

L E

C O

M M

U N

IC

A

T

IO

N S

E

N L

A R

G E

D P

L A

N

T-401

T E

L E

C O

M U

N

IC

A Z

IO

N

I

P

IA

N T

E I

N G

R A

N D

IT

E

14125586

SEK

SCALE: 1 : 50 / SCALA 1:50

TELECOMMUNICATIONS - ENLARGED PLAN / TELECOMUNICAZIONI - PLANIMETRIA AMPLIATA

C1

SCALE:1:50

1 mmM 2 mmM 4 mmM

1 SEE SHEET T-001 FOR TELECOMMUNICATIONS NOTES, SYMBOLS, AND

ABBREVIATIONS. / VEDI SCHEDA T-001 PER LE NOTE DI

TELECOMUNICAZIONE, SIMBOLI E ABBREVIAZIONI.

SCALE: NTS / SCALA: NON IN SCALA

NIPR RACK ELEVATION / ALTEZZA RACK NIPR

A1 SCALE: NTS / SCALA: NON IN SCALA

SIPR 1 RACK ELEVATION / ALTEZZA RACK SIPR 1

A2 SCALE: NTS / SCALA: NON IN SCALA

SIPR 2 RACK ELEVATION / ALTEZZA RACK SIPR 2

A3

GENERAL SHEET NOTES / NOTE GENERALI

SHEET KEYNOTES / FOGLIO NOTE PRINCIPALI

1. WALL MOUNTED ELECTRICAL PANEL, EXISTING / PANNELLO ELETTRICO A

MURO, ESISTENTE.

2. FLOOR MOUNTED TELECOM RACK, EXISTING / RACK TELECOMUNICAZIONI

A PAVIMENTO, ESISTENTE.

3. WALL MOUNTED PLYWOOD, EXISTING / PANNELLO COMPENSATO A MURO,

ESISTENTE.

4. OSP CONDUIT STUB UP, EXISTING / TRONCO DI LINEA CONDOTTA OSP,

ESISTENTE.

5. FLOOR MOUNTED TELECOM EQUIPMENT CABINET, 600mm X 910mm X 2130mm, NEW; WITH REAR-MOUNTED VERTICAL POWER DISTRIBUTION

UNIT (PDU) FOR EQUIPMENT POWER; COORDINATE WITH END-USER FOR

PDU INPUT PLUG AND PDU RECEPTACLE TYPES / APPARECCHIATURE DI

TELECOMUNICAZIONE A PAVIMENTO, 600mm X 910mm X 2130mm, NUOVA

CON L'UNITÀ DI DISTRIBUZIONE DELL'ALIMENTAZIONE (PDU) VERTICALE

MONTATA POSTERIORMENTE PER L'ALIMENTAZIONE DELLE

APPARECCHIATURE; COORDINARSI CON L'UTENTE FINALE PER I TIPI DI

SPINA DI INGRESSO PDU E PRESA PDU.

6. ONE (1) 4" EMT, NEW / UN (1) EMT 4”/10CM, NUOVO.

7. SBB / SBB.

0m m M

IN

FINAL GRADE / (LIVELLO FINALE)

WARNING TAPE /

(NASTRO DI

SEGNALAZIONE)

SELECTED

BACKFILL /

(RIEMPIMEN

TO

SELEZIONA

TO)

CONCRETE ENCASMENT /

(INVOLUCRO IN CALCESTRUZZO)

(TYP ALL AROUND) / (TIP. SU TUTTA LA CIRCONFERENZA)

80mm MIN 80mm MIN

SPARE WITH STRING /

(RICAMBIO CON

CORDICELLA)

3-CELL FABRIC

DUCT / (DOTTO

IN TESSUTO A

3 CELLE)

0m m

CABLE TRAY /

(PASSERELLA PORTA-CAVI)

CONDUIT WITH

PULL STRING /

(CONDOTTA CON

CORDICELLA)

TELECOMM WALL

OUTLET BOX /

(CASSETTA PRESE A

MURO PER

TELECOMUNICAZIONI)

CEILING / (SOFFITTO)

3" MIN CLEARANCE / (SPAZIO MIN 3”/ 30CM)

C

LE

AR

AN

C E

(S

PA

ZI

O

" M

IN

C

LE

AR

AN

C

E (S

PA

ZI

O M

IN

2” / 3

0C M

CONDUIT WITH

PULLSTRING /

(CONDOTTA CON

CORDICELLA)

BOND STUB UP TO

CABLE TRAY USING #2 AWG

GROUND CONDUCTOR (TYP) /

(COLLEGARE TRONCO DI LINEA

ALLA PASSERELLA PORTA-CAVI

CON CONDUTTORE DI TERRA

AWG N.2) (TIP.)

#2 AWG BARE GROUNDING

CONDUCTOR RUNNING LENGTH

OF TRAY / (N.2 CONDUTTORE DI

COLLEGAMENTO A TERRA NUDO AWG

PER LA LUNGHEZZA DELLA

PASSERELLA)

TELECOMM WALL

OUTLET BOX /

(CASSETTA PRESE A

MURO PER

TELECOMUNICAZIONI)

DATA PORT

RJ45

CAT6 /

(PORTA DATI

RJ45

CAT6)

PROVIDE 127mm x 127mm x 73mm BACKBOX WITH RING

ADAPTER FOR FACE PLATE /

(FORNIRE CASSETTA 127mm X 127mm X 73mm CON

ADATTATORE AD ANELLO PER

LA PIASTRA ANTERIORE)

DATA PORT

RJ45 CAT6 /

(PORTA

DATI RJ45

CAT6)

DATA PORT

RJ45

CAT6 /

(PORTA DATI

RJ45

CAT6)

DATA

PROVIDE 127mm x 127mm x 73mm BACKBOX WITH RING

ADAPTER FOR FACE PLATE /

(FORNIRE CASSETTA 127mm X 127mm X 73mm CON

ADATTATORE AD ANELLO PER

LA PIASTRA ANTERIORE)

DATA

DATA PORT

RJ45

CAT6 /

(PORTA DATI

RJ45

CAT6)

S

DATA PORT

RJ45

CAT6 /

(PORTA DATI

RJ45

CAT6)

DATA

PROVIDE 127mm x 127mm x 73mm BACKBOX WITH RING

ADAPTER FOR FACE PLATE /

(FORNIRE CASSETTA 127mm X 127mm X 73mm CON

ADATTATORE AD ANELLO PER

LA PIASTRA ANTERIORE)

DATA

DATA PORT

RJ45

CAT6 /

(PORTA DATI

RJ45

CAT6)

DDC

DATA PORT

RJ45

CAT6 / (PORTA

DATI

RJ45

CAT6)

DATA

PROVIDE 127mm x 127mm x 73mm BACKBOX WITH RING

ADAPTER FOR FACE PLATE /

(FORNIRE CASSETTA 127mm X 127mm X 73mm CON

ADATTATORE AD ANELLO PER

LA PIASTRA ANTERIORE)

DATA

DATA PORT

RJ45

CAT6 / (PORTA

DATI

RJ45

CAT6)

TV

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F

A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-T

.r v t

/6

/2

:0

:5

P M

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D

E T

A

IL

T-501

T E

L E

C O

M U

N

IC

A Z

IO

N

I

D E

T T

A G

L I

14125587

SEK

SCALE: NTS / SCALA: NON IN SCALAC1

4-WAY CONCRETE ENCASED DUCTBANK /

BLOCCO CONDOTTE IN INVOLUCRO IN

CALCESTRUZZO A 4 VIE

SCALE: NTS / SCALA: NON IN SCALAA1

BASKET CABLE TRAY TO OUTLET CONDUIT

TRANSITION / PASSERELLA PORTA-CAVI A

CONTENITORE VERSO LA TRANSIZIONE

DELLA CONDOTTA IN USCITA

SCALE: NTS / SCALA: NON IN SCALAC2

TYPICAL OUTLET WALL PLATE UNCLASS /

TIPICA PIASTRA A MURO CON PRESE NON

CLASSIFICATA

SCALE: NTS / SCALA: NON IN SCALAC3

TYPICAL OUTLET WALL PLATE CLASSIFIED /

TIPICA PIASTRA A MURO CON PRESE

CLASSIFICATA

SCALE: NTS / SCALA: NON IN SCALAC4

TYPICAL OUTLET WALL PLAT DDC / TIPICA

PIASTRA A MURO CON PRESE DDC

SCALE: NTS / SCALA: NON IN SCALAA3

TYPICAL OUTLET WALL PLATE TV / TIPICA

PIASTRA A MURO CON PRESE TV

GROUND LUG

(TYP) /

STAFFETTA

DI TERRA

(TIP)

#6 AWG GROUND WIRE /

(N.6 CAVO DI TERRA AWG)

LADDER RACK

(AS SHOWN ON

ENLARGED PLANS) /

(RACK A SCALA) (COME

MOSTRATO SULLE

PLANIMETRIE

AMPLIATE)

FIRE RATED WALL / (PARETE RESISTENTE AL FUOCO)

FIRE RATED SLEEVE

ASSEMBLY

PENETRATIONS

THROUGH WALL FOR

ACCESS TO CABLE

TRAY (TYP) / PENETRAZIONI

A MANICA IGNIFUGA NELLA

PARETE PER L'ACCESSO

ALLA PASSERELLA PORTA-

CAVI (TIP.)

1. SURFACE MOUNTED CHANNEL MUST BE SECURELY FASTENED INTO

THE SLAB, WALL, ETC. SUFFICIENTLY TO CARRY THE LOAD OF THE

TRAY AND ITS CONTENTS WITH A SAFETY FACTOR OF 3. / IL CANALE

IN SUPERFICIE DEV'ESSERE ADEGUATAMENTE FISSATO ALLA

LASTRA, PARETE ECC. IN MODO TALE DA SOPPORTARE IL CARICO

DELLA PASSERELLA E DEL SUO CONTENUTO CON UN FATTORE DI

SICUREZZA 3

2. ALL CHANNEL, TRAY FITTINGS, AND ACCESSORIES ARE TO BE

GALVANIZED. / TUTTI GLI ELEMENTI DI FISSAGGIO DELLE

PASSERELLE, I CANALI E GLI ACCESSORI DEVONO ESSERE ZINCATI.

BASKET TRAY

(AS SHOWN ON

ENLARGED PLANS) / PASSERELLA A

CONTENITORE (COME MOSTRATO SULLE

PLANIMETRIE AMPLIATE)

#2 AWG BARE WIRE BONDING

CONDUCTOR RUNNING ENTIRE LENGTH

OF BASKET TRAY / (N.2 CONDUTTORE DI

COLLEGAMENTO A FILO NUDO AWG PER

L'INTERA LUNGHEZZA DELLA

PASSERELLA A CONTENITORE)

USE HOOK AND LOOP STRIPS TO

SECURE CABLES TO RUNWAY / USARE

FASCETTE AD ANELLO E GANCI PER

FISSARE I CAVI ALLA PISTA

VERTICAL WALL BRACKET / (STAFFA A MURO VERTICALE)

RUNWAY FOOT KIT / (KIT BASE DELLA PISTA)

BONDING BUSHING / (BOCCOLA DI COLLEGAMENTO)

FLOOR SLAB / (LASTRA DEL PAVIMENTO)

EQUIPMENT BONDING

CABLE / (CAVO DI COLLEGAMENTO DELLE APPARECCHIATURE)

CONNECTOR / (CONNETTORE)

CONDUIT SLEEVES OR

CONDUITS THRU FLOOR SLAB.

NUMBER OF CONDUIT PER RISER

DIAGRAM / (MANICOTTI DELLE CONDOTTE O

CONDOTTE CHE ATTRAVERSANO UNA LASTRA

DEL PAVIMENTO.

NUMERO DI CONDOTTE DA SCHEMA DELLA

COLONNA)

SECURELY ANCHOR

RUNWAY FOOT TO FLOOR

/ (FISSARE

ADEGUATAMENTE LA

BASE DELLA PISTA AL

PAVIMENTO)

WALL / (PARETE)

38mm METAL FRAMING

CHANNEL ANCHORED

TO WALL 100mm O.C. /

(CANALE CON PROFILO

METALLICO DA 38mm

FISSATO AL MURO

100mm C.E)

CABLE RUNWAY / (PISTA PER CAVO)

TELECOMMUNICATIONS CABLES

PER RISER DIAGRAMS / (CAVI

PER TELECOMUNICAZIONI COME

DA SCHEMI DELLA COLONNA)

(3) 100mm CONDUITS UON. / (CONDOTTE DA 100mm SE NON

DIVERSAMENTE INDICATO)

BRACKET / (STAFFA)

MESH TYPE

CABLE TRAY / (PASSERELLA

PORTACAVI A RETE)

CONDUIT / (CONDOTTO)

GROUNDING WIRE / (FILO

DI MESSA A TERRA)

GROUNDING LUG / (STAFFETTA DI MESSA

A TERRA)

MESH TYPE CABLE TRAY /

(PASSERELLA PORTACAVI A

RETE)

U-BOLT / (BULLONE A U)

MESH TYPE CABLE TRAY

/ (PASSERELLA

PORTACAVI A RETE)

FASP

GROUNDING LUG / (STAFFETTA DI

MESSA A TERRA)

GROUNDING BONDING WIRE/

(FILO DI COLLEGAMENTO A

TERRA)

THREAD ROD /

(ASTA

FILETTATA)

SPLICE MOUNTING

HARDWARE /

(COMPONENTI PER IL

MONTAGGIO DELLA

GIUNZIONE)

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F

A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-T

.r v t

/6

/2

:0

:5

P M

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D

E T

A

IL

T-502

T E

L E

C O

M U

N

IC

A Z

IO

N

I

D E

T T

A G

L I

14125588

SEK

SCALE: NTS/ SCALA: NON IN SCALAC1

BASKET CABLE TRAY TO LADDER TYPE

CABLE RUNWAY WALL PENETRATION /

PENETRAZIONE DEL MURO DA PASSERELLA

PORTA-CAVI A CONTENITORE A PISTA PER

CAVO DI TIPO A SCALA

SCALE: NTS / SCALA: NON IN SCALAA1

CABLE - VERTICAL RUNWAY MOUNTING /

CAVO - MONTAGGIO DELLA PISTA VERTICALE

SCALE: NTS / SCALA: NON IN SCALAC3

CABLE TRAY - CONDUIT ATTACHMENT /

PASSERELLA PORTA-CAVI - COLLEGAMENTO

ALLA CONDOTTA

SCALE: NTS / SCALA: NON IN SCALA

CABLE TRAY - STANDARD SUPPORT (OPTIONAL DOUBLE LAYER) DETAIL / PASSERELLA

PORTA-CAVI - DETTAGLIO SUPPORTO STANDARD (DOPPIO STRATO OPZIONALE)

A3

OFT SIMULATOR BAY /

BAIA SIMULATORE OFT

COMPUTER / IG /

COMPUTER /IG

1:100

0 1 32 4 5 10

SCALE: SCALE:

PLAN

NORTH

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

1684614

11/07/22

Richard Tyler, PE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

A V

IA

N

O A

IR

B

A

IA

N

O

IT

A

L Y

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

SS

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

LMM / BTN

FIRE PROTECTION DPS

F

A

D A

L C

O M

B A

T R

E S

C U

E H

E L

IC

O P

T

U L A

T O

R F

A C

IL

IT

Y

P

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N O

R F

O L

K V

A A

T L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

A T

LA

N

TI

C

DRAWFORM REVISION: 12 APRIL 2018

ISSUED FOR CONSTRUCTION – 10 MAR 2023

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD AS NOTED

B

IM

/1

P

S im u la to r/

B L D

G P

-1

-T

.r v t

/6

/2

:0

:0

P M

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D

E T

A

IL

T-503

T E

L E

C O

M U

N

IC

A Z

IO

N

I

D E

T T

A G