ATTACHMENT 1b - FSB2020-270-00 - WI-ANG - 3-Bay Hangar - ADD 01 COMBINED DRAWINGS (2 of 2).pdf
PDF 28 MB Posted
- Attached to
- F-35 THREE BAY SPECIALIZED HANGAR
- Solicitation number
- W50S9F-22-B-0001
- Issued by
-
Department of the Army National Guard
About this file
This solicitation is for the construction of a new three-bay hangar at Dane County Regional Airport in Madison, Wisconsin. The project involves demolishing an existing 19,875 square foot building and constructing a new 31,000 square foot three-bay hangar to support the F-35 mission. Scope of work includes pre-conditioned aircraft air, 270VDC power, fire suppression, HVAC, administrative and shop spaces, a lightning protection system, fall protection, and an Advantor security system. The contract will be a single award fixed-price construction contract issued by the Department of the Army National Guard. The base bid is for hangar construction with options for a paint/mix addition and aircraft-rated pavement. The bid opening will be conducted on SAM.gov. Interested contractors must register in SAM and check the website for any amendments. The projected value is between $25-100 million and the contract duration is 550 days from notice to proceed. The NAICS code is 236220 for commercial and institutional building construction.
View the file
Other files
Show 40 more
Latest 50 of 147 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RUNNER CHANNEL
SCHEDULED FRAME
SCHEDULED DOOR
EXTEND GYP BD @
RATED PARTITION
PARTITION TYPE
PER FLOOR PLANS
RE: FLOOR PLANS
PARTITION
CONT SEALANT,
BOTH SIDES
EQ EQ
CONT SEALANT, BOTH SIDES HM FRAME
DOUBLE JAMB STUDS AT ALL
JAMBS (CLIP TOGETHER AT
12" OC VERT)
JAMB ANCHORS,
3 PER JAMB MIN.
PERPENDICULAR
PARTITION PER PLAN
R E:
F
LO
O R
P
LA
N S
PA
R
TI
TI
O N
LOW EXPANSION FOAM FILL
SCHEDULED DOOR
SCHEDULED DOOR,
PROVIDE 1/2" UNDERCUT
SCHEDULED
FRAME BEYOND
4" 1" 1/2"
EDGE OF FOUNDATION
PROVIDE ALUMINUM
OFFSET SADDLE
THRESHOLD OR
APPROVED EQUAL.
INSTALL IN FULL BED
OF SILICONE SEALANT
OFFSET T.O. SIDEWALK 1/4"
FROM T.O. FOUNDATION
EXPANSION MATERIAL
1/ 2"1/
4" 1/
4"
SLOPE
PROVIDE INVERTED ALUMINUM
DOOR SHOE WITH RAIN DRIP
OR APPROVED EQUAL
TERMINATE
FLOORING AT
THRESHOLD EDGE
LANDING 1:50 MAX
SIDEWALK 1:20 MAX
SCHEDULED DOOR
CMU BOND BEAM
EQ EQ
GROUT FILL
CONT SEALANT,
BOTH SIDES
RE: FLOOR PLANS
CMU
4"
HM FRAME
1"
HM FRAME
CMU
GROUT FILL
CONT SEALANT,
BOTH SIDES
SCHEDULED DOOR
FRAME ANCHORS,
3 PER JAMB MIN.
R E:
F
LO
O R
P
LA
N
C M
U
3/16" 2"
EQ
EQ
SCHEDULED DOOR
CMU BOND BEAM
GROUT FILL
CONT SEALANT,
BOTH SIDES
RE: FLOOR PLANS
CMU
4"
HM FRAME
3 5/8" 2" 4"
1'-5 1/4"
BRICK VENEER
THERMAL AIR
SPACE
RIGID INSUL.
1"6 X 10 X 5/16
LOOSE LINTEL
2 5/8" 8 3/4" 5 7/8"
PREFINISHED
METAL FLASHING
WEEPS
CAVITY MESH
HM FRAME
CMU
GROUT FILL
CONT SEALANT,
BOTH SIDES
SCHEDULED DOOR
FRAME ANCHORS,
3 PER JAMB MIN.
R E:
F
LO
O R
P
LA
N
C M
U 4"
2"
5/ 8"
GROUT FILL
THERMAL AIR SPACE
1' -5
/4
SPLIT FACE VENEER
4" RIGID INSUL.
5/
8"
3/ 4"
RUNNER CHANNEL
SCHEDULED FRAME
SCHEDULED DOOR
EXTEND GYP BD @
RATED PARTITION
PARTITION TYPE
PER FLOOR PLANS
4"
RE: FLOOR PLANS
PARTITION
CONT SEALANT,
BOTH SIDES
1"
SHEATHING
EIFS DRAINAGE BACKING
RIGID INSUL.
EIFS FINISH
3/4" PLYWOOD
MTL. STUD BOX HEADER
HEAD FLASHING
DRIP EDGE
AIR BARRIER
1'-1 1/4"
5/8" GYP. BD.
CONT SEALANT, BOTH SIDES
HM FRAME
DOUBLE JAMB STUDS AT ALL
JAMBS (CLIP TOGETHER AT
12" OC VERT)
JAMB ANCHORS,
3 PER JAMB MIN.
5/
8" 2"
4"
R E:
F
LO
O R
P
LA
N S
PA
R
TI
TI
O N
LOW EXPANSION FOAM FILL
SCHEDULED DOOR
SPLIT FACE VENEER
THERMAL AIR BARRIER
RIGID INSUL.
AIR BARRIER
3/4" PLYWOOD
1' -6
/8
1"
FINISHED SOFFIT
109'-0"
WOOD BLOCKING
BUILT UP 8" CFMF
BOX BEAM HEADER
CEILING AS SCHEDULED
METAL CHANNEL
BACKER ROD & SEALANT
BOTH SIDES
CURTAIN WALL SYSTEM
8" CFMF
5/8" GYP. BD. ON EA. SIDE
BACKER ROD & SEALANT
WOOD BLOCKING
METAL INSUL. SOFFIT
6" CFMF
3/4" PLYWD.
PLYWOOD BLOCKING
AIR BARRIER
BREAK MTL FLASHING
1"
RE: FLOOR PLANS
SOLID SURFACE SILL W/
EASED EDGES, RE:
INTERIORS A-602
SCHEDULED WINDOW
INSULATION
GYP BD
SPLIT FACE VENEER
CAST STONE COPING
EIFS BEYOND
MTL FLASHING W/ END DAMS
BACKER ROD & SEALANT
EA. SIDE
AIR BARRIER
RIGID INSUL.
PLYWOOD
SHEATHING
CONT L3X3X3/16 GALV
ANGLE ATTACHED
TO TO STUDS WITH 2 #10
TEK SCREWS AT 16" O.C.
1"
0°
1/2"
BACKER ROD & SEALANT
EA. SIDE
SCHEDULED DOOR
EIFS
AIR BARRIER
SOLID SURFACE SILL
RE: INTERIORS A-602
INSULATION
8" CFMF
GYP. BD.
PLYWOOD SHEATHING
PLYWOOD BLOCKING
R E:
F
LO
O R
P
LA
N S
1/ 2" 1
EIFS ON 4" INSUL.
AIR BARRIER
MTL. STUD BOX HEADER
PLYWOOD SHEATHING
8"CFMF
INSULATION
GYP BD
METAL FLASHING
DRIP EDGE
CURTAIN WALL
BACKER ROD & SEALANT
EA. SIDE
RE: FLOOR PLANS
SUN SHADE
1/2"1/2"
SOLID SURFACE ON
EA SIDE
12" CMU WALL
SCHEDULED WINDOW
SHIM & CAULK
EQ
EQ
SHIM & CAULK
SCHEDULED WINDOW
SOLID SURFACE BELOW
12" CMU WALL
12" CMU WALL
SCHEDULED WINDOW
SHIM AND CAULK
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\gaz\D o cum ents\02700_Arch_G Zalabak Z5W
7D .rvt
4/20/2022 11:22 :40 AM
DETAILS
A-500
JMI
BDR
JBC
SCALE: 3" = 1'-0"
HEAD DETAILD1
SCALE: 3" = 1'-0"
JAMB DETAILC1
SCALE: 3" = 1'-0"
SILL DETAILB1
SCALE: 3" = 1'-0"
HEAD DETAILD2
SCALE: 3" = 1'-0"
JAMB DETAILC2
3" 9"6"0
3" = 1'-0"
SCALE: 3" = 1'-0"
HEAD DETAILD3
SCALE: 3" = 1'-0"
JAMB DETAILC3
SCALE: 3" = 1'-0"
HEAD DETAILD4
SCALE: 3" = 1'-0"
JAMB DETAILC4
SCALE: 3" = 1'-0"
CURTAIN WALL HEAD DETAILA1
SCALE: 1 1/2" = 1'-0"
CURTAIN WALL SILL DETAILB2 SCALE: 1 1/2" = 1'-0"
CURTAIN WALL JAMB DETAILB3 SCALE: 1 1/2" = 1'-0"
CURTAIN WALL HEAD DETAILB4
SCALE: 1 1/2" = 1'-0"
WINDOW SILL DETAILA2 SCALE: 1 1/2" = 1'-0"
WINDOW JAMB DETAILA3 SCALE: 1 1/2" = 1'-0"
WINDOW HEAD DETAILA4
6" 1'-6"1'0
1 1/2" = 1'-0"
1 ADDENDUM 1 04/22/2022
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
OKLAHOMA CITY
OK
OVERHEAD
COILING DOOR
OVERHEAD COILING
DOOR JAMB GUIDES
OVERHEAD COILING
DOOR HOOD
CMU BOND BEAM
RE: FLOOR PLANS
CMU
OVERHEAD COILING
DOOR JAMB GUIDES
STEEL ANGLE
BY MANF.
OVERHEAD
COILING DOOR
CMU
R E:
F
LO
O R
P
LA
N
C M
U
EXPANSION
ANCHOR BOLT
CMU BOND BEAM
OVERHEAD DOOR HOOD
HEADPLATE BEYOND
OVERHEAD DOOR
OVERHEAD DOOR
JAMB GUIDES
RE: FLOOR PLANS
CMU
CONT SEALANT, BOTH SIDES
DOUBLE JAMB STUDS TYP
AT ALL JAMBS (CLIP
TOGETHER AT 12" OC VERT)
ALUMINUM
WINDOW
SYSTEM
R E:
F
LO
O R
P
LA
N S
PA
R
TI
TI
O N
2" 4 1/2"
1/
2"
6"
3/8" 2"
HEAD/SILL
INSULATED
OUTSIDE GLAZING
JAMB
INSULATED
OUTSIDE GLAZING
HEAD/JAMB/SILL
INT 1/4" GLZ
SHIM AS REQUIRED
@ EXT: LOW EXPANSION FOAM FILL
IN PERIMETER FRAME JOINT CAVITY
@INT: SHIM AS REQUIRED
FABRIC HANGAR DOOR
WEATHER TIGHT SEAL
PROVIDED BY FABRIC DOOR
MFR
MFR
EXTRUSION
VERTICAL
INSULATED METAL
WALL PANEL
INSULTED METAL
SOFFIT PANEL
CFMF
CFMF
CHANNEL
DOOR CLEAR HEIGHT
121'-8 1/2"
6'
1/
2"
GROUND FLOOR
100'-0"
PAVING (REFER TO CIVIL)
SLAB OF GRADE
WITH RIDGE AT
CENTER OF DOOR
FABRIC HANGAR DOOR
FLOOR SEAL WITH
SAFETY EDGE
1/4" / 1'-0"1/4" / 1'-0"
SCHEDULED WINDOW
SHIM & CAULK
SCHEDULED FLOOR
CONC. FLOOR SLAB
SHIM & CAULK
SCHEDULED WINDOW
GYP BD
PLYWOOD BLOCKING
6" CFMF W/ SOUND BATT
INSUL.
6" CFMF W/ SOUND
BATT INSUL.
SCHEDULED WINDOW
6" CFMF BOX BEAM
PLYWOOD BLOCKING
GYP BD
SHIM AND SEALANT
5/8" GYP BD
(2 LAYERS)
FIRE SEALANT
6" CH STUD
6" CHANNEL
BEAM
ANGLE
8" BOND BEAM
1" SHAFT
LINER
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:24 :49 PM
DETAILS
A-501
JMI
BDR
JBC
SCALE: 3" = 1'-0"
HEAD DETAILD2 SCALE: 3" = 1'-0"
JAMB DETAILD3SCALE: 3" = 1'-0"
HEAD DETAILD1
SCALE: 3" = 1'-0"
STOREFRONT, HEAD, JAMB, SILL DETAILSA3
SCALE: 1 1/2" = 1'-0"
HEAD DETAILB1
SCALE: 1 1/2" = 1'-0"
SILL DETAILA1 3" 9"6"0
3" = 1'-0"
6" 1'-6"1'0
1 1/2" = 1'-0"
SCALE: 1 1/2" = 1'-0"
WINDOW SILL DETAILB3 SCALE: 1 1/2" = 1'-0"
WINDOW JAMB DETAILB4 SCALE: 1 1/2" = 1'-0"
WINDOW HEAD DETAILB5
SCALE: 1 1/2" = 1'-0"
SECTION DETAILA5
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
GROUND FLOOR
100'-0"
SCHEDULED GLAZING
SHIM AND SEALANT
BACKER ROD
AND SEALANT
PAVING, REFER
TO CIVIL
SLAB ON GRADE
ROOF FRAMING
115'-0"
STEEL
STRUCTURE
ROOF
MEMBRANE
6" ROOF
INSULATION
(R-30)
STEEL DECK
5/8" SHEATHING ON
EA SIDE
ROOF PROTECTION
BOARD
DEFLECTION TRACK
8" CFMF
A.3
SHIM TRACK
13 ROOF
MEMBRANE
6" ROOF
INSULATION
(R-30)
STEEL
DECK
2 LAYERS 5/8"
GYP. BD.
CH STUD
STEEL BEAM
DEFLECTION
TRACK
1" SHAFT LINER
BATT
INSULATION
(R-25)
ROOF
PROTECTION
BOARD
STEEL COLUMN
+/- 9 1/4" +/- 9 1/4"
GROUND FLOOR
100'-0"
ONE HOUR
RATED 8"
CMU
1' -4
SLAB ON
GRADE
FOOTING
8" 8"
SCHEDULED
BASE
8" CMU BOND BEAM,
RE: STRUCTURAL
GROUND FLOOR
100'-0"
ONE HOUR
RATED 12"
CMU WALL
5/8" GYPSUM
WALLBOARD
8" BATT
INSULATION
(R-25)
8" CFMF
SLAB ON GRADE
PORCELAIN
WALL TILE
8" TRACK
FOOTING
SCHEDULED BASE
C
ADMIN ROOF
116'-8"
ROOF
MEMBRANE
6" ROOF
INSULATION
(R-30)
STEEL DECK
12" CMU
8" BATT
INSULATION
(R-25)
8" CFMF
5/8" GYPSUM
WALLBOARD
4" VERTICAL
INSULATED METAL
PANEL (R-32)
ROOF
PROTECTION
BOARD
8" TRACK
TURN MEMBRANE
UP PANEL (SIM
D5/AE-502)
CFMF
INFILL AT
16" O.C.
FASTNER
EXPANSION
JOINT (EJ-2)
FLEXIBLE
FLASHING
FT WOOD
BLOCKING
STEEL ANGLE
STEEL
STRUCTURE
STEEL CHANNEL
VAPOR
BARRIER
1'-2"
10"
8" CMU GROUT
FILLED
CAST STONE
COPING
4" SPLIT
FACED CMU
4" CAVITY WALL
INSULATION (R-15)
4" INSULATED
METAL PANEL
VERTICAL JOINT
(R-32)
BACKER ROD
& SEALANT
STEEL CHANNEL
STEEL COLUMN
L3X3X3/16 STEEL
ANGLE CONT GALV
W/ DIA POST
INSTALLED
ANCHOR AT 24" OC
BACKER ROD
& SEALANT
PERIMETER
ANGLE
1"
PREFINSIHED
METAL FLASHING
GROUND FLOOR
100'-0"
ONE HOUR
RATED 8" CMU
WALL
4" CAVITY WALL
INSULATION
(R-15)
4" CMU SPLIT-FACED
FLUID APPLIED
AIR BARRIER
PRE-FINISHED
METAL FLASHING
WEEP
CONCRETE CURB
MORTAR NET
PAVEMENT
(REFER CIVIL)
REFER PLANS
BACKER ROD &
SEALANT
TRANSLUCENT
PANELS (R-12.5)
4" INSULATED
METAL PANEL
VERTICAL JOINT
(R-32)
STEEL CHANNEL
INSTALL PANELS
PER MFG SPECIFICATIONS
STEEL COLUMN
STEEL ANGLE
TRANSLUCENT
PANELS
(R-12.5)
4" INSULATED
METAL PANEL
VERTICAL JOINT
(R-32)
STEEL CHANNEL
STEEL COLUMN
INSTALL PANELS
PER MFG SPECIFICATIONS
STEEL ANGLE
1'-4" 10"
4" INSULATED
METAL PANEL
VERTICAL JOINT
(R-32)
EXTEND ROOF
MEMBRANE UP &
OVER PARAPET
6" ROOF
INSULATION
(R-30)
STEEL DECK
ROOF
PROTECTION
BOARD
PRE-FINISHED
METAL PARAPET
CAP
WOOD
BLOCKING
TAPERED
INSULATION
8" BATT
INSULATION
(R-25)
STEEL
STRUCTURE
EXTERIOR
SHEATHING
FT WOOD
BLOCKING
STEEL ANGLE
2'-2"
SLOPE
BATT
INSULATION
(R-25)
EXTERIOR
GYPSUM
WALLBOARD
EXTERIOR
INSULATION AND
FINISH SYSTEM
(E.I.F.S.) (R-16)
8" CFMF
EXTERIOR
SHEATHING
PRE-FINISHED
METAL
PARAPET CAP
EXTEND ROOF
MEMBRANE UP &
OVER PARAPET
WOOD
BLOCKING
6" ROOF
INSULATION
(R-30)
STEEL DECK
VAPOR BARRIER
ROOF
PROTECTION
BOARD
T.O. PARAPET
119'-4"
STEEL
STRUCTURE
COMPRESSION
BAR
FT WOOD
BLOCKING
STEEL ANGLE
SLOPE
1'-2" TYP.
GROUND FLOOR
100'-0"
EDGE OF SLAB
CAVITY WALL
INSULATION (R-15)
8" CFMF
BATT INSULATION (R-25)
5/8" GYP. BD.
EXTERIOR SHEATHING
FLUID APPLIED AIR
BARRIERWEEP
4" CMU
SPLIT FACE
SCHEDULED BASE
8" TRACK
8"
CAST STONE
COPING
PRE-FINISHED
METAL FLASHING
PAVEMENT
(REFER CIVIL)
GROUT FILL
GRAVEL FILL
MORTAR NET
MASONRY
WALL TIES
PREFINSIHED
METAL FLASHING
BACKER ROD
& SEALANT
REFER PLANS
CONT L3X3X3/16 GALV
ANGLE ATTACHED
TO TO STUDS WITH 2 #10
TEK SCREWS AT 16" O.C.
EXTERIOR
INSULATION AND
FINISH SYSTEM
(E.I.F.S.) (R-16)
BOND BREAKER
FINISHED SOFFIT
109'-0"
ROOF MEMBRANE OVER
PROTECTION BOARD
EDGE ANGLE
6" ROOF TAPERED
INSULATION (R-30)
PRE-FINISHED
METAL DRIP EDGE
HORIZONTAL
INSULATED METAL
PANELS - COLOR #2
MEMBRANE
FLASHING
CONTINUOUS
CLEAT
TREATED WOOD
BLOCKING
STEEL
CHANNEL
EXTERIOR
SHEATHING ON
CFMF
EXTERIOR
SHEATHING ON
CFMF
INSULATED METAL
PANELS - COLOR #2
M
IN
8"
COORDINATE
THROUGH WALL
FLASHING DETAIL
WITH PANEL MFR
PRE-FINISHED
METAL REGLET
AND COUNTER
FLASHING
ROOFING
MEMBRANE
TURNED UP
METAL PANEL
9'-1 1/4"
MFR
EXTRUSION BACKER ROD
& SEALANT,
EA. SIDECURTAINWALL
SYSTEM
CFMF BOX
BEAM
STEEL
STRUCTURE
WOOD
BLOCKING
CEILING AS
SCHED.
5/8" GYP BD
8" CFMF
BATT
INSULATION
SHIM AS
REQUIRED
TREATED WOOD
BLOCKING
STEEL DECK
SLOPE
T.O. PARAPET
119'-4"
4' -0
COMPRESSION
BAR
PRE-FINISHED METAL
PARAPET CAP
WOOD BLOCKING
VAPOR
RETARDER
6" ROOF
INSULATION (R-30)
ROOF PROTECTION
BOARD
EXTEND ROOF
MEMBRANE UP &
OVER PARAPET
STEEL DECK
ONE HOUR
RATED 8" CMU
8" CFMF
EXTERIOR
SHEATHING
BATT INSULATION
(R-25)
VAPOR
BARRIER
EXTERIOR
INSULATION AND
FINISH SYSTEM
(E.I.F.S.) (R-16)
STEEL ANGLE
SLOPE
J
METAL
DECK
6" ROOF
INSULATION
R(30)
ROOFING
MEMBRANE
OVER ROOF
PROTECTION
BOARD
WOOD
BLOCKING
EXPANSION
JOINT (EJ-1)
4" INSULATED
METAL PANEL
VERTICAL JOINT
(R-32)
ROOF MEMBRANE
COUNTER-
FLASHING
AIR BARRIER
STEEL
COLUMN
8" CMU
3-5/8" CFMF @
16" OC
VERTICALLY
COUNTER-
FLASHING
10"
EDGE ANGLE
SHEET METAL
CLOSURE
ATTACHED ONLY
TO CMU
FILL CAVITY
WITH BATT
INSULATION
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:23 :27 PM
DETAILS
A-502
JMI
JRT/JBC
JBC
SCALE: 1 1/2" = 1'-0"
SECTION DETAILB3
SCALE: 1 1/2" = 1'-0"
SECTION DETAILC3
SCALE: 1 1/2" = 1'-0"
SECTION DETAILB2
SCALE: 1 1/2" = 1'-0"
SECTION DETAILA2
SCALE: 1 1/2" = 1'-0"
SECTION DETAILC2
6" 1'-6"1'0
1 1/2" = 1'-0"
SCALE: 1 1/2" = 1'-0"
SECTION DETAILD2
SCALE: 1 1/2" = 1'-0"
SECTION DETAILB1
SCALE: 1 1/2" = 1'-0"
SECTION DETAILA1
SCALE: 1 1/2" = 1'-0"
SECTION DETAILC1B
SCALE: 1 1/2" = 1'-0"
SECTION DETAILC1A
SCALE: 1 1/2" = 1'-0"
SECTION DETAILD1
SCALE: 1 1/2" = 1'-0"
SECTION DETAILD3
SCALE: 1 1/2" = 1'-0"
SECTION DETAILA3
SCALE: 1 1/2" = 1'-0"
SECTION DETAILD5
SCALE: 1 1/2" = 1'-0"
SECTION DETAILB5
SCALE: 1" = 1'-0"
SECTION DETAILA5
0 6" 1' 2'
1" = 1'-0"
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
8" CFMF
EXTERIOR INSULATION
AND FINISH SYSTEM
(E.I.F.S.) (R-16)
FLUID-APPLIED
MEMBRANE AIR
BARRIER
MANUFACTURED
ALUM CANOPY
1/2" EXTERIOR
GYPSUM SHEATHING
HANGAR ROD
8" CFMF BOX
BEAM
6'-0"
BACKER ROD AND
SEALANT
110' - 4"
BO CANOPY
BENT PLATE PAINTED TO
MATCH EIFS COLOR
8" CFMF BOX
BEAM
5/8" GYP BD
CFMF
1/2" EXTERIOR
GYPSUM
SHEATHING
EXTERIOR INSULATION
AND FINISH SYSTEM
(E.I.F.S.) (R-16)
BACKER ROD &
SEALANT
FLUID-APPLIED
MEMBRANE AIR
BARRIER
3/4"
1/2" EXTERIOR
GYPSUM SHEATHING
EXTERIOR
INSULATION AND
FINISH SYSTEM
(E.I.F.S.) (R-16)
FLUID-APPLIED
MEMBRANE AIR
BARRIER
NOTE: REVEAL DIMENSIONS ARE MEASURED TO
THE CENTERLINE OF THE REVEAL
3/4"
CL
3/ 4"
3/ 4"
3/ 4"
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:24 :54 PM
DETAILS
A-503
JBC
GAZ
GAZ
SCALE: 1 1/2" = 1'-0"
PRE-ENGINEERED METAL CANOPYA1
SCALE: 1 1/2" = 1'-0"
EIFS CONTROL JOINT DETAILC1
SCALE: 1 1/2" = 1'-0"
EIFS REVEAL JOINTB1
6" 1'-6"1'0
1 1/2" = 1'-0"
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
C
STEEL COLUMN
5/8" GYPSUM
WALLBOARD
4 1/2" CURTAIN
WALL SYSTEM
BATT
INSULATION
(R-25)
CAVITY WALL
INSULATION
(R-15)
4" SPLIT-FACED CMU
EXTERIOR
SHEATHING
6" METAL STUD 8" CFMF
WOOD
BLOCKING
B.7
6" CURTAIN
WALL SYSTEM
STEEL COLUMN
3/4" PLYWOOD
BLOCKING
5/8" GYP. BD ON 8" CFMF
1/ 2"
T
YP
*I6
CAST STONE
COPING ABOVE
FLUID APPLIED
AIR BARRIER
BACKER ROD &
SEALANT EA. SIDE
1"
AIR SPACE
BATT INSULATION (R-25)
5/8" GYPSUM WALLBOARD
WOOD BLOCKING
BACKER ROD &
SEALANT EA. SIDE
1'-9 1/4"
3/4" PLYWOOD
BLOCKING
AESS STEEL
COLUMN
6" CURTAIN
WALL SYSTEM
C.2
4.3
6" CURTAIN
WALL SYSTEM
STEEL
COLUMN
5/8" GYP ON
8" CFMF
6" CURTAIN
WALL SYSTEM
A6
8" METAL
STUD
BATT
INSULATION
(R-25)
CAVITY WALL
INSULATION (R-15)
EXTERIOR
SHEATHING
4" SPLIT-
FACED CMU
4.3
FLUID
APPLIED AIR
BARRIER
1/ 2"
T
YP
BACKER ROD & SEALANT
BOTH SIDES
3/4" PLYWOOD BLOCKING
8" CFMF
BACKER ROD &
SEALANT
1" M
IN
. 10
/2
M
6" CMU
CAVITY WALL
INSULATION
(R-15)
FLUID
APPLIED AIR
BARRIER
4" CMU
SPLIT FACE
BACKER ROD
AND SEALANT
SPRAY FOAM
INSULATION
STEEL TUBE
STEEL CHANNEL
(BY FABRIC
DOOR MFR)
1 3/4"
4'-9 1/2"
8" CMU
STEEL COLUMN
METAL PANEL
TYPICAL 1-3/8" AIR
SPACE AT ALL EXTERIOR
HANGAR WALLS
1'-5"
CLOSURE
TRIM PIECE
1'-3 1/2" 10"
1 1/2"
1'-5 3/4" 1'-3 1/2"
6" CMU
CAVITY WALL
INSULATION
(R-15)
FLUID
APPLIED AIR
BARRIER
4" CMU
SPLIT FACE
COLUMN
F2
CLOSURE
TRIM PIECE
METAL
PANEL
BACKER ROD
AND SEALANT
SPRAY FOAM
INSULATION
INSULATED
METAL PANEL
CAST STONE
BELOW
BATT
INSULATION
(R-25)
J
EXPANSION
JOINT (EJ-2)
STEEL TUBE
STEEL
CHANNELS (BY
FABRIC DOOR
MFR)
3/
4"
1' -5
2-1/2" METAL
STUD
5/8" GYP BD
8" METAL STUD
8" CMU
10"
1 HR. RATED
CMU WALL
A6
CURTAIN WALL
SYSTEM
1" MIN.
CAST STONE
COPING ABOVE
SPLIT FACE CMU
AIR SPACE
FLD APLD AIR
BARRIER
5/8" GYP. BD.
BATT INSULATION
5/8" GYP. BD.
10" CFMF
BACKER ROD &
SEALANT EA SIDE
EIFS FINISH
3/4" PLYWOOD BLKG.
8" CFMF
5/8" GYP. BD.
8" METAL STUD
10" METAL STUD
6" CFMF
6" METAL
STUD
G
COLUMN
CURTAIN WALL
SYSTEM
*M12C
RIGID INSUL.
AIR SPACE
4" CMU SPLIT FACE
CAST STONE COPING,
ABV.
8" CFMF
BATT INSUL.
(R-25)
5/8" GYP. BD.
BACKER ROD AND
SEALANT BOTH SIDES
3/4" PWD
BLOCKING
MIN.
1"
VAPOR
BARRIER
FLD APLD AIR BARRIER
1 HR. RATED 12" CMU
R
EF
ER
P
LA
N
4" CMU
SPLIT FACE
8" CMU
CAVITY
WALL
INSULATION
(R-15)
FABRIC DOOR WITH
WEATHER TIGHT SEAL
PROVIDED BY MANF
6' -5
9' -3
1'-5" 10"
8" 8"
FLUID
APPLIED AIR
BARRIER
FIRE RATED
EXPANSION
JOINT (EJ-2)
SPRAY FOAM
INSULATION
H
BACKER ROD
AND SEALANT
STEEL TUBE
STEEL CHANNEL (BY
FABRIC DOOR MFR)
FABRIC DOOR WITH
WEATHER TIGHT SEAL
PROVIDED BY MANF
STEEL CHANNEL (BY
FABRIC DOOR MFR)
STEEL TUBE
BACKER ROD AND SEALANT
SPRAY FOAM INSULATION
1 3/4"
1'-5"
TYPICAL 1-3/8" AIR
SPACE AT ALL
EXTERIOR
HANGAR WALLS
A-307 A4
3' -2
/2
3'
-2
/2
1 HR. RATED
CMU WALL
FIRE RATED
EXPANSION JOINT
(EJ-2)
J
8"
COLUMN
5/8" GYP BD ON
2-1/2" MTL STUDS
5/8" GYP BD ON
8" CFMF
COLUMN
FLUID
APPLIED AIR
BARRIER
EIFS
EXPANSION
JOINT (EJ-2)
CAST STONE
BELOW
EXTERIOR
SHEATHING
FLUID
APPLIED AIR
BARRIER
4" CMU SPLIT
FACE
CAVITY WALL
INSULATION
(R-15)
8" RATED CMU
TO EXTEND
10'-0" BEYOND
ADJACENT
WALL
10"
1 HR. RATED
CMU WALL
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:24 :44 PM
PLAN DETAILS
A-505
JBC/TDB
GAZ
GAZ
SCALE: 1 1/2" = 1'-0"
PLAN DETAILC1
SCALE: 1 1/2" = 1'-0"
PLAN DETAILB1 SCALE: 1 1/2" = 1'-0"
PLAN DETAILB2
SCALE: 1 1/2" = 1'-0"
PLAN DETAILA1
SCALE: 1 1/2" = 1'-0"
PLAN DETAILC3
SCALE: 1 1/2" = 1'-0"
PLAN DETAILB3
SCALE: 1 1/2" = 1'-0"
PLAN DETAILA3 SCALE: 1 1/2" = 1'-0"
PLAN DETAILA4 6" 1'-6"1'0
1 1/2" = 1'-0"
SCALE: 1 1/2" = 1'-0"
PLAN DETAILD5
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
8" CMU
SEALANT, TYP.
8" METAL STUD
8" CFMF
5/8" GYP. BD.
6" METAL STUD
5/8" GYP. BD.
8" CFMF
8" CFMF
FLUID APPLIED
AIR BARRIER
SPLIT FACE CMU
CAVITY WALL
INSULATION (R15)
2-1/2" METAL
STUD
5/8" GYP. BD.
2-1/2" CHANNEL
BATT
INSULATION
BATT INSULATION
5/8" GYP. BD.
EXTERIOR
SHEATHING
BATT
INSULATION
CAST STONE
COPING ABOVE
1 3/4"
SPLIT FACE CMU
CAVITY WALL
INSULATION (R-15)
FLUID APPLIED
AIR BARRIER
EXTERIOR
SHEATHING
CAST STONE
COPING ABOVE
8" CMU
8" CFMF
5/8" GYP. BD.
BATT INSULATION
SEALANT, TYP.
8" CFMF
5/8" GYP. BD.
BATT INSULATION
A.3
A.3
1" MIN.
CURTAIN WALL
SYSTEM
CAST STONE
COPING ABOVE
SPLIT FACE CMU
FLUID
APPLIED AIR
BARRIER
BATT INSULATION
BACKER ROD &
SEALANT EA SIDE
EIFS FINISH
3/4"
PLYWOOD
BLKG.
5/8" GYP. BD.
8" CFMF
6" CFMF
5/8" GYP. BD.
1 HR RATED
12" CMU
5/8" GYP. BD.
SEALANT, TYP.
RIGID INSUL.
3/
4"
7 3/4" 1'-0 1/2"
B.9CAST STONE
COPING ABOVE
SPLIT FACE CMU
CAVITY WALL
INSULATION (R-15)
FLUID APPLIED AIR
BARRIER
EXTERIOR
SHEATHING
8" CMU DOOR AND FRAME
AS SCHED.
12" CMU
METAL PANEL
CLOSURE TRIM
PIECE
4 3/4"
1 3/4"
8" CFMF
BATT
INSULATION
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:25 :10 PM
PLAN DETAILS
A-506
JBC/TDB
JEP
GAZ
SCALE: 1 1/2" = 1'-0"
PLAN DETAILA1
SCALE: 1 1/2" = 1'-0"
PLAN DETAILB1
SCALE: 1 1/2" = 1'-0"
PLAN DETAILA2
SCALE: 1 1/2" = 1'-0"
PLAN DETAILC1
6" 1'-6"1'0
1 1/2" = 1'-0"
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:25 :00 PM
ISOMETRIC EXPANION JOINT
A-510
JBC
GAZ
MP
SCALE:
NW VIEW1
SCALE:
SW VIEW2
GENERAL NOTES
A. FIRE PROTECTION, PLUMBING, MECHANICAL, AND
PLUBMING ARE NOT SHOWN FOR CLARITY.
B. EJ-1: ROOF TO WALL CONDITION
C. EJ-2: WALL TO WALL CONDITION
EJ-2
EJ-2
EJ-2
EJ-2
EJ-2
EJ-1
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:25 :06 PM
ISOMETRIC EXPANION JOINT
A-511
JBC
GAZ
MP
SCALE:
SE VIEW1
SCALE:
NE VIEW2
GENERAL NOTES
A. FIRE PROTECTION, PLUMBING, MECHANICAL, AND
PLUBMING ARE NOT SHOWN FOR CLARITY.
B. EJ-1: ROOF TO WALL CONDITION
C. EJ-2: WALL TO WALL CONDITION
EJ-2
EJ-2
EJ-1
EJ-2
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
S2 STEEL
D O
O R
H
EI
G H
T 2"
2" 2"DOOR WIDTH
S4 STEEL
D O
O R
H
EI
G H
T 4"
2" 2"DOOR WIDTH 2" 2"DOOR WIDTH
D2 STEEL
D O
O R
H
EI
G H
T 2"
2" 2"DOOR WIDTH
D4 STEEL
D O
O R
H
EI
G H
T 4"
D O
O R
H
EI
G H
T
DOOR WIDTH
SFX STEEL, EXT
SFI STEEL, INT
SFB STEEL, 45-MIN FR
WFI WOOD, INT
D O
O R
H
EI
G H
T
DOOR WIDTH
WNLI WOOD, INT
GLAZING
REF SPECS
FOR TYPE
D O
O R
H
EI
G H
T
DOOR WIDTH
AFGX ALUM, EXT
GLAZING
REF SPECS
FOR TYPE
2'
D O
O R
H
EI
G H
T
DOOR WIDTH
CCDI COILING COUNTER DOOR, INT
D O
O R
H
EI
G H
T
DOOR WIDTH
SGX STEEL, EXT
GLAZING
REF SPECS
FOR TYPE
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:20 :00 PM
DOOR SCHEDULE
A-600
JMI
JRT/JBC
JBC
DOOR SCHEDULE
MARK
DOOR
FIRE
RATING STC
FRAME
HARDWARE NOTES
SIZE DOOR
TYPE TYPE
DETAIL
WD HGT THK HEAD JAMB SILL
101A 3'-0" 7'-0" 1 3/4" SFB 45 MIN S4 D2/AE-500 C2/AE-500 C711R
101C 3'-0" 7'-0" 1 3/4" SGX S4 D3/AE-500 C3/AE-500 C715
101D 3'-0" 7'-0" 1 3/4" SGX S4 D3/AE-500 C3/AE-500 D725
101E 3'-0" 7'-0" 1 3/4" SGX S4 D3/AE-500 C3/AE-500 D725
102A 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 800AV
103 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101
104 3'-0" 7'-0" 1 3/4" WNLI S2 D2/AE-500 C2/AE-500 101
105A 3'-0" 7'-0" 1 3/4" AFGX S2 715A
105B 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 CX731
105C 3'-0" 7'-0" 1 3/4" SFB 45 MIN D2/AE-500 C2/AE-500 C711R
107 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101
108 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101
109 3'-0" 7'-0" 1 3/4" WFI S2 D1/AE-500 C1/AE-500 801
110 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101
111 3'-0" 7'-0" 1 3/4" WFI S2 D1/AE-500 C1/AE-500 801
112 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101
113 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 801
114A 6'-0" 7'-0" (2)AFGX D2 714A
114B 6'-0" 7'-0" (2)AFGX D2 A1/AE-501 A1/AE-501 800AV
115 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101
116 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101
117A 3'-0" 7'-0" 1 3/4" WFI S4 D1/AE-500 C1/AE-500 341R
117B 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 203
118 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN D4 D2/AE-500 C2/AE-500 D210R
119A 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN D4 C710R
120A 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 801
120B 3'-0" 7'-0" 1 3/4" WNLI S2 801
121 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 201
122 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 201
123 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 201
124 6'-0" 7'-0" 1 3/4" (2)SFX D4 D4/AE-500 C4/AE-500 214
125 6'-0" 7'-0" 1 3/4" (2)SFX D4 D4/AE-500 C4/AE-500 214
126A 6'-0" 7'-0" 1 3/4" (2)SFI D2 D1/AE-500 C1/AE-500 210
126B 6'-0" 7'-0" 1 3/4" (2)SFX D4 D4/AE-500 C4/AE-500 214
126C 4'-0" 4'-0" 3/4" CCDI - - - 001
127A 6'-0" 7'-0" (2)AFGX D2 B2/AE-505 B3/AE-502 714A
127B 6'-0" 7'-0" (2)AFGX D2 A1/AE-501 A1/AE-501 800AV
128A 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN D4 C710R
128B 6'-0" 7'-0" 1 3/4" (2)SGX D4 D3/AE-500 C3/AE-500 D724
131 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 801
131A 3'-0" 7'-0" 1 3/4" SFI S4 801
132 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 341
133 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 341
134A 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 801
135 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 341
137 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 801
137A 3'-0" 7'-0" 1 3/4" SFI S4 801
138 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 341
139A 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 801
140 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 341
141 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 341
142 4'-0" 7'-0" 1 3/4" SFB S4 C201R
143 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 203
145 6'-0" 7'-0" 1 3/4" (2)SFX - D4/AE-500 C4/AE-500 714
146 6'-0" 7'-0" 1 3/4" (2)SFX - D4/AE-500 C4/AE-500 714
SCALE: 1/2" = 1'-0"
FRAME TYPES
SCALE: 1/2" = 1'-0"
DOOR TYPES
0 1' 2' 4'
1/2" = 1'-0"
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
9' -0
3' -4
3'
-8
2' -0
TYP NOTE
HEAD
JAMB
SILL
A
D5/AE-502
B1&C1/AE-505
B3/AE-502
7' -0
T
T
TTT
T
T
6'-0" EQEQ
11'-3"
9' -0
2' -0
3'
-8
3' -4
9'-1"
EQ EQ EQ
TYP NOTE
HEAD
JAMB
SILL
B
D5/AE-502
C1&B2/AE-505
B3/AE-502
TTT
GROUND FLOOR
100'-0"
9' -0
EQEQEQ 6'-0" EQ
TYP NOTE
HEAD
JAMB
SILL
C
A4/AE-501
A4/AE-501
B3/AE-502
TT
T T T
TT
7' -0
"TT
2' -0
3'
-8
3' -4
4'-0"
SUNSHADE
PER
ELEVATIONS
4' -0
3'
-4
TYP NOTE
HEAD
JAMB
SILL
D
B4/AE-500
B3/AE-500
B2/AE-500
1/
2"
1/ 2"
1' -4
5'-5"
4' -0
3'
-4
TYP NOTE
HEAD
JAMB
SILL
E
B4/AE-500
B3/AE-500
B2/AE-500
9' -0
3' -4
3'
-8
2' -0
TYP NOTE
HEAD
JAMB
SILL
F
A1/AE-500
A3/AE-505
B3/AE-502
7' -0
T
T
T
T
T
T T
EQ 3'-0" EQ
8'-0"
9' -0
8'-0"
EQ 6'-0" EQ
2' -0
3'
-8
3' -4
TYP NOTE
HEAD
JAMB
SILL
G
A1/AE-500
B2/AE-505
B1/AE-500
T
T
T
T
T
7' -0
"T T
GROUND FLOOR
100'-0"
TYP NOTE
HEAD
JAMB
SILL
H
A1/AE-500
B3/AE-500
B1/AE-500
T TT
T T
8'-0"
EQ 6'-0" EQ
9' -0
2' -0
3'
-8
3' -4
7' -0
"T T
7' -2
3'-8"
TYP NOTE
HEAD
JAMB
SILL
I
B2/AE-501
B3/AE-501
B4/AE-501
T
PRIVACY FILM -
REFER TO SHEET
AE-402 / B1
6 1/4" 2'-11 3/4" 2"
7' -2
6 1/4"
31'-8 3/8"
2" EQ EQ EQ EQ EQ EQ EQ EQ EQ
TYP NOTE
HEAD
JAMB
SILL
J
B2/AE-501
B3/AE-501
B4/AE-501
T T T T T T T T T
PRIVACY FILM - REFER TO
SHEET AE-402 / B1
GROUND FLOOR
100'-0"
4' -0
3'
-4
TYP NOTE
HEAD
JAMB
SILL
K
A4/AE-500
A3/AE-500
A2/AE-500
1, 3
FIRE SHUTTER ON
HANGAR SIDE
GENERAL NOTES
A. ALL FRAME DIMENSIONS ARE NOMINAL ROUGH
OPENING AND CONTRACTOR SHALL COORDINATE
ACTUAL OPENING SIZES WITH RESPECT TO
REQUIRED SHIM SPACE AND ADJACENT MATERIAL.
B. NO EXPOSED FASTENERS SHALL BE ALLOWED IN
ALUMINUM CURTAINWALL FRAMES.
C. PROVIDE MINIMAL EXPANDING FOAM AT PERIMETER
SHIM CAVITY.
D. REFER TO SPECIFICATION SECTION 087100-GLAZING
FOR GLAZING TYPES.
E. TEMPERED GLAZING IS INDICATED WITH A "T".
F. EXTERIOR GLAZING SHALL BE INSULATED.
G. INTERIOR GLAZING SHALL BE NON-INSULATED.
SHEET KEYNOTES
1. CURTAINWALL SYSTEM: 2" X 4 - 1/2" SCREW SPLINE
OR SHEAR BLOCK UNLESS NOTED OTHERWISE.
2. BUTT GLAZED VERTICAL JOINT WITH 2" - 4 - 1/2"
EXTERIOR FRAMING SYSTEM UNLESS NOTED
OTHERWISE.
3. GLAZING IN HANGAR SHALL BE INSULATED.
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:24 :39 PM
WINDOW ELEVATIONS
A-601
JMI
GAZ
MP
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
FINISH I.D
FINISH LEGEND
DESCRIPTION PRODUCT LINE OR COLOR SIZE
FLOORING FINISHES
CPT-1 CARPET TILE 3HDP NORDIC STONES-HIDDEN PLAINS / 13-119 ESKER 50CMx50CMx0.31"
PCT-1 PORCELAIN CERAMIC TILE ALASKA ASK04 GLACIER 24"x48"x10.5mm
BASE FINISHES
RB-1 RUBBER BASE TRADITIONAL THERMOSET RUBBER TA6
BEDROCK
WALL FINISHES
PT-1 PAINT
PT-2 PAINT
PT-3 PAINT
PCT-2 PORCELAIN CERAMIC TILE
PCT-7a PORCELAIN CERAMIC TILE
PCT-8a PORCELAIN CERAMIC TILE
PCT-2 PORCELAIN CERAMIC TILE ALASKA ASK04 GLACIER 12"x24"x10.5mm PCT-3 PORCELAIN CERAMIC TILE CBX17 I SEE THE MOON 12"x24"x3/8" PCT-4 PORCELAIN CERAMIC TILE CBX17 I SEE THE MOON I SEE THE MOON; MOSAICS 3"x3"x1/4"
WOC WALK-OFF TILE TT-12 FLUFF CORD STRIP TILE BLACK 12"x12"
COMMENTS
QUARTER TURN INSTALLATION
STACKED INSTALLATION
STACKED INSTALLATION
STACKED INSTALLATION
SHOWER FLOORS
QUARTER TURN INSTALLATION
4" H
PTB-1 PORCELAIN TILE BASE ALASKA ASK04 GLACIER BULLNOSE 4"x24"
WITH TOE FOR RESILIENT;
TOELESS FOR CARPETING
PCT-5 PORCELAIN CERAMIC TILE 12"x24"x3/8"CBX03 SLINKY TILE PATTERN 'A' PCT-6 PORCELAIN CERAMIC TILE 6"x24"x5/16"RETRO ACTIVE ROYAL NAVY PO
6"x24"x10.5mm
6" x 24" x 5/16"
FIELD
12"x24"x10.5mm
CASEWORK FINISHES
PLAM PLASTIC LAMINATE PRALINES AND CREAM WW160 ...
... COUNTERTOPS
SSM-1 SOLID SURFACE MATERIAL CHILLED EARTH 9228SS
ESD ELECTROSTATIC DISSIPATIVE TILE 24"x24"x0.080"ESD RUBBER TILE F410 MARENGO ...
RSF RESILIENT SHEET FLOORING 3mm SHEETSENTICA COLOR: 6525 OCEAN MIST HEAT WELDED SEAMS
SC-1 SEALED CONCRETE
SC-2 SEALED CONCRETE ...CLEAR SEALANT ...
GT-2 GLASS TILE COLOR WAVE STRAIGHT JOINT LINER CW14 TWILIGHT BLUE 1"x6"x5/16" GT-1 GLASS TILE COLOR WAVE RANDOM INTERLOCKIG EVENING MIXER CW28 12"x18"x5/16" ADD 25% MIX OF 1"x6" TWILIGHT BLUE TO
INTERLOCKING MOSAIC EVENING MIXER
ALASKA ASK04 GLACIER
TILE PATTERN 'A'
TILE PATTERN 'B'
TILE PATTERN 'B'
TILE PATTERN 'C'
SHADES AV248 THUNDER UPS 50% MIX
SHADES AV248 THUNDER HON 50% MIX
RETRO ACTIVE ROYAL NAVY PTN
RETRO ACTIVE ROYAL NAVY UPS
RETRO ACTIVE ROYAL NAVY PO
RETRO ACTIVE ROYAL NAVY UPS
4" x 12" x 5/16" 4" x 24" x 5/16" 6" x 12" x 5/16"
... WINDOW SILLSSSM-2 SOLID SURFACE MATERIAL BONE MATTE
PCT-7b
CEILING FINISHES
ACT-1 ACOUSTICAL CEILING TILE CIRRUS HIGH NRC ANGLED TEGULAR NO. 556 WHITE
PT-5 PAINT
24"x24"x7/8"
...0011 SUGAR DUST ...
PRELUDE 15/16" EXPOSED TEE WHITE
MISC. FINISHES
TP TOILET PARTITION HDPE; HAMMERED STAINLESS
WS WINDOW SHADES ...5X MANUAL SHADE SYSTEM; SCREENS 1550 SERIES
3% OPEN. SHADE: 1554 BLACK/BROWN
FASCIA:QUAKER BROWN
GR1 GROUT #540, COLOR: TRUFFLE ... USE WITH PCT1 & PCT2 FLOOR TILES
GR2 GROUT #542, COLOR: GRAYSTONE ... USE WITH TILE PATTERN 'A'
GR3 GROUT #370, COLOR: DOVE GRAY ... USE WITH TILE PATTERN 'B'
SG1 SIGNAGE COPY COLOR: 710 LIGHT GREY
SG2 SIGNAGE HEADER INSERT FINISH: 734 DARK GREY
SG3 SIGNAGE SLIMLINE ENDCAP: 101-ALU ALUMINUM
SG4 SIGNAGE ACCENT INSERT FINISH: 734 DARK GREY
TS TRANSITIONS FINISH: SATIN ANODIZED ALUMINUM ... REFER TO TRANSITION LEGEND IN101 FOR
TRANSITION TYPES
GR4 GROUT #544, COLOR: ROLLING FOG ... USE WITH GLASS TILE
EXMD EXPOSED METAL DECK ...0011 SUGAR DUST ...
EXSF EXPOSED STRUCT. FRAMING ...0011 SUGAR DUST ...
EXDW EXPOSED DUCTWORK &
EQUIPMENT
...0011 SUGAR DUST ...
INSTL INTERIOR STEEL DOORS AND
FRAMES
0508 MIDNIGHT MAGIC
FEC FIRE EXTIGUISHER CABINET STAINLESS STEEL
EXMP EXPOSED METAL PIPING ...0850 CITRON SEMI-GLOSS; ALL METAL PIPES W/OUT
FACTORY APPLIED PAINT OR PROTECTIVE
COATING
LKR LOCKER
EWP ELECTRIC SWITCHES &
RECEPTACLES WALL PLATES
STAINLESS STEEL
ESR ELECTRIC SWITCHES &
RECEPTACLES
GRAY
ACP ACCESS PANELS PAINT TO MATCH ADJACENT SURFACE
EP ELECTRICAL PANEL ANSI 61 GRAY OR STANDARD GRAY FINISH
TWP TELECOMMUNICATION
RECEPTACLE WALL PLATES
STAINLESS STEEL
TA TOILET ACCESSORIES STAINLESS STEEL NO. 4
FRRF FIVE COAT FUEL RESISTIVE
RESINOUS FLOORING
...PRIME: STANDARD PRIMER ...
EPOXY MORTAR: GS; COLOR: SILVER GRAY
GROUT COAT: GS4; COLOR; CLEAR
TOPCOAT: SK6; COLOR: CLEAR FLAT
SEALANT: MP7
0523 FELICITY
0526 METROPOLIS MOOD
0508 MIDNIGHT MAGIC
PCT-8b PCT-8c PCT-8d
ACT-2 ACOUSTICAL CEILING TILE OPTIMA HEALTH ZONE SQUARE TEGULAR NO. 3214PB WHITE 24"x24"x1" CLEAN ROOM 15/16" EXPOSED TEE WHITE
PRF PRIVACY FILM CUSTOM DESIGN TO BE SELECTED BY BASE
SSCG STAINLESS STEEL CORNER
GUARD
STANDARD TYPE 304 STAINLESS STEEL NO. 4 SATIN FINISH 3-1/2" WINGS ...
SSKP STAINLESS STEEL
KICKPLATE
TYPE 304 STAINLESS STEEL NO. 4 SATIN FINISH 12" HIGH ...
FRP-1 FIBERGLASS REINFORCED PANEL 4'x8' ...CLASS A; PEBBLED P100 WHITE
PRIME: STANDARD PRIMER
EPOXY MORTAR: GS; COLOR: SILVER GRAY
GROUT COAT: GS4; COLOR; CLEAR
SEALANT: MP7
FRP-2 FIBERGLASS REINFORCED PANEL 4'x8' ...CLASS A; SMOOTH S 100 S/2/S WHITE
FRP-2 FIBERGLASS REINFORCED PANEL 4'x8' ...CLASS A; SMOOTH S 100 S/2/S WHITE
SG5 SIGNAGE COPY COLOR: 735 RED
VANGUARD; COLOR: 028 GRAY
INTERIOR FINISH
ABBREVIATION LEGEND
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISHED FLOOR
CPT CARPET TILE
GYP BD GYPSUM WALL BOARD
ESD ELECTROSTATIC DISSIPATIVE TILE
EXP EXPOSED
FRP FIBERGLASS REINFORCED PLASTIC
FRRF FUEL RESTISTIVE RESINOUS FLOORING
GT GLASS TILE
PCT PORCELAIN CERAMIC TILE
PTB PORCELAIN TILE BASE
PT PAINT
PLAM PLASTIC LAMINATE
RB RESILIENT BASE
RSF RUBBLER SHEET FLOORING
RS ROLLER SHADES
SC SEALED CONCRETE
SSM SOLID SURFACE MATERIAL
TP TOILET PARTITION
WD WOOD
WOC WALK-OFF TILE
WS WINDOW SHADE
GENERAL NOTES
A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD
BE CONSIDERED AS COMPLEMENTARY TO THE
CONSTRUCTION DOCUMENTS AS A WHOLE. ANY
QUESTIONS OR CONFLICTS SHOULD BE BROUGHT
TO THE ARCHITECTS ATTENTION.
B. REFER TO FINISH PLAN SHEETS (IN101 THROUGH
IN102) FOR EXTENTS OF WALL FINISHES.
C. REFER TO FINISH PLAN SHEETS (IN101 THROUGH IN
102) FOR FLOORING INSTALLATION PATTERN.
D. REFER TO INTERIOR FINISH DETAILS SHEET IN-103
FOR WALL TILE PATTERNS.
E. PROVIDE A SMOOTH TRANSITION BETWEEN
DIFFERENT FLOOR MATERIALS.
F. ALL WINDOW SILLS SHALL BE SOLID SURFACE
MATERIAL, SSM-2, UNLESS NOTED OTHERWISE.
G. CENTER FLOORING IN ROOM U.N.O. ON FINISH
PLAN.
H. DO NOT INSTALL TILE LESS THAN 3". CONFIRM
WITH ARCH. PRIOR TO INSTALLATION.
I. REFER TO FINISH MATERIALS SCHEDULE AE-602
FOR MATERIAL MANUFACTURER AND COLOR.
J. REFER TO INTERIOR ELEVATIONS FOR WALL
FINISH/DESIGN INTENT & ENLARGED PLANS.
K. THERE SHALL BE NO EXPOSED TILE EDGES, USE
SCHLUTER TRIM AS INDICATED, TO FINISH ALL
EDGES. SEE DETAILS (SHEET IN-103)
1. PROVIDE TILE PATTERN 'A' ON ALL WALLS.
2. PROVIDE TILE PATTERN 'B' ON ALL WALLS.
3. PROVIDE TILE PATTERN 'C' ON ALL WALLS AS
INDICATED ON INTERIOR ELEVATION SHEETS AE-402
& AE-403 AND FLOOR FINISH PLANS ON SHEETS
IN-101 & IN-102
4. PROVIDE WINDOW SHADES AND SOLID SURFACE
(SSM-2) WINDOW SILLS AT ALL EXTERIOR WINDOWS
THIS ROOM.
5. PAINT FURDOWN ABOVE CABINETS PT-2.
6. REFER TO DETAIL D3/IN-103 FOR WALL TILE TO
FLOOR TRANSITION.
FINISH SCHEDULE NOTES
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\gaz\D o cum ents\02700_Arch_G Zalabak Z5W
7D .rvt
4/20/2022 11:22 :25 AM
ROOM FINISH SCHEDULE &
FINISH MATERIALS SCHEDULE
A-602
JMI/TDB
JRT/JBC/TLW
JBC
ROOM FINISH SCHEDULE
ROOM NO. ROOM NAME
FLOOR
FINISH
BASE
FINISH
WALL FINISHES
CEILING FINISH CEILING HEIGHT NOTESNORTH SOUTH EAST WEST
101 WEAPONS TRAINING FRRF - - PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
102 VEST FRRF RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'
103 SHARED OFFICE PCT-1 PTB-1 PT-1 PT-1 PT-2 PT-1 ACT-1 9' 4
104 FUEL OPEN OFFICE PCT-1 PTB-1 PT-1 PT-2 PT-1 PT-1 ACT-1 9' 4
105 VEST WOC-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'
106 CORR PCT-1 PTB-1 PT-1/PT-2/TILE PAT 'C' PT-1 PT-1/PT-2 PT-1 ACT-1 9' 3
107 CLASSROOM CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'
108 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 9' 4
109 RR W PCT-2 - - TILE PAT 'B' TILE PAT 'B' TILE PAT 'B' TILE PAT 'B' GYP BD / PT-5 9' 2
110 WING WEAPONS MGR CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 9' 4
111 RR M PCT-2 - - TILE PAT 'B' TILE PAT 'B' TILE PAT 'B' TILE PAT 'B' GYP BD / PT-5 9' 2
112 FUEL SUPERVISOR CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 9' 4
113 BREAK/ TRAINING PCT-1 PTB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9' 5
114 VEST WOC-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'
115 OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1 9' 4
116 VINYL OPEN OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 9' 4
117A MOTHER'S ROOM PCT-2 PTB-1 PT-1 PT-1 PT-1 PT-1 GYP BD / PT-5 9'
117B JAN SC-2 RB-1 FRP-1/PT-1 FRP-1/PT-1 FRP-1/PT-1 FRP-1/PT-1 EXP / PT-5 OPEN TO DECK 118 FUEL MAINT. GENERAL STORAGE SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
119 FUEL CELL FRRF - - PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
120A VEST RSF-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'
120B CORR RSF-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'
121 ELEC SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK 1
122 FUEL SC-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-2 9'
123 WASH SC-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-2 9'
124 MECH SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
125 FIRE SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
126 TOOLS SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
127 VEST WOC-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'
128 WASH BAY FRRF - - PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
130 CLEAN M RR PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 131 CLEAN M LR PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 132 CLEAN SHOWER M PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 133 DIRTY SHOWER M PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 134 DIRTY LR M PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' ACT-2 9' 1 135 DIRTY SHOWER M PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 136 CLEAN W RR PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 137 CLEAN W LR PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 138 CLEAN SHOWER W PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 139 DIRTY LR W PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' ACT-2 9' 1 140 DIRTY SHOWER W PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 141 DIRTY RR UNISEX PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 142 DIRTY VEST FRRF RB-1 TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' ACT-1 9' 6 143 MASK WASHING SC-2 RB-1 FRP-1/PT-1 FRP-1/PT-1 FRP-1/PT-1 FRP-1/PT-1 EXP / PT-5 OPEN TO DECK
145 ELEC SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
146 COMM ESD - - PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK
1 ADDENDUM 1 04/22/2022
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
T
T
A
A
C
C
17 17
16 16
ELEC
DIRTY LR M
DIRTY VEST
DIRTY LR W
1'-2"
53'-9 1/8"
22'-0 1/4"
DIRTY
SHOWER W
DIRTY RR
UNISEX
141DIRTY
SHOWER M
DIRTY
SHOWER M
MASK
WASHING
PAINT/SAND/MIX
B1 A-701
C1 A-701
A1 A-701
144B*
144C*
A-701 B4
A-701 B4
A.3
B.9
B.9
'-8
/8
6'-4"
BOLLARD
12'-0" 25'-2"
3" 3"
1' -5
/8
'-6
/8
1'
-2
12' x 6"
TRENCH DRAIN
DIRTY ROOM
144.2
'-8
/8
'-9
/8
20'-10 7/16"
*A6
*Z6
ENVELOPE 6
CLEAN ROOM
144.1
4.
1*
4.
2*
3'-6"
3' -6
25'-0"
3' -6
RATING
10'-0"
144.3*
144A*
A6
A19A6 A6
AIR SHOWER
144.3
F2
*Z6
144.2B*
EXTENTS OF PAINT BOOTH
GROUND FLOOR
100'-0"
AC
A-701 C4
EXTERIOR INSULATION
FINISH SYSTEM
CAST STONE
COPING
SPLIT-FACED
COLORED CMU
T.O. PARAPET
119'-4"
A.3B.9
AWNING
GROUND FLOOR
100'-0"
171819
EXTERIOR INSULATION
FINISH SYSTEM
CAST STONE
COPING
SPLIT-FACED
COLORED CMU
T.O. PARAPET
119'-4"AWNING
MECHANICAL
LOUVER
GROUND FLOOR
100'-0"
HIGH ROOF HANGAR
BAY
134'-4"
EXTERIOR INSULATION
FINISH SYSTEM
CAST STONE
COPING
SPLIT-FACED
COLORED CMU
T.O. PARAPET
119'-4"
A
A
C
C
A-701 C4
A-701 C4
LOW-SLOPE
MEMBRANE ROOF
A.3
B.9
B.9
AWNING
MECHANICAL
EQUIPMENT
PRIMARY
ROOF
DRAIN
OVERFLOW
ROOF
DRAIN
EXTERIOR
LIGHT FIXTURE
GROUND FLOOR
100'-0"
171819
LOAD-BEARING CMU
WALL
HORIZONTAL
INSULATED
METAL PANELS
CAST STONE
COPING
SPLIT-FACE
COLORED CMU
LOW-SLOPE MEMBRANE'
ROOFING
ONE-HOUR FIRE
RATED WALL
A3 A-701
T.O. PARAPET
119'-4"
PAINT/SAND/MIX
DIRTY VEST
'-4
AWNING
SLOPED TOP GYB BD
4"/12" SLOPE
GROUND FLOOR
100'-0"
B2 A-701
A2 A-701
EDGE OF SLAB
CAVITY WALL
INSULATION (R-15)
SPLIT-FACED CMU
CAST STONE
COPING
BATT
INSULATION
(R-25)
5/8" GYPSUM
WALLBOARD
SCHEDULED
CEILING
VAPOR
BARRIER
EXTERIOR
INSULATION
AND FINISH
SYSTEM
(E.I.F.S.)
(R-16)
EXTERIOR
SHEATHING
8" CFMF
8" CFMF
BATT
INSULATION
(R-25)
T.O. PARAPET
119'-4"
MASONRY WALL TIES
BACKER ROD
& SEALANT
STEEL ANGLE
AWNING
EARTH & GRAVEL
EXTERIOR LIGHT
FIXTURE
GROUND FLOOR
100'-0"
EDGE OF SLAB
RIGID CAVITY WALL
INSULATION (R-15)
8" CFMF
5/8" GYP. BD.
PRE-FINISHED
METAL
FLASHING
WEEP
2" THERMAL
SPACE
4" CMU
SPLIT FACE
8" TRACK
8"
MORTAR NET
MASONRY
WALL TIES
SCHEDULED BASE
GROUT FILL
GRAVEL FILL
EARTH
BATT INSULATION (R-25)
EXTERIOR SHEATHING
EXTERIOR INSULATION AND
FINISH SYSTEM (E.I.F.S.) (R-16)
8" CFMF
5/8" GYPSUM WALLBOARD
PRE-FINISHED METAL
PARAPET CAP
ROOF MEMBRANE
WOOD BLOCKING
6" ROOF INSULATION (R-30)
STEEL DECK
VAPOR BARRIER
ROOF MEMBRANE WRAPPED
UP AND OVER TOP OF
PARAPET
ROOF PROTECTION BOARD
T.O. PARAPET
119'-4"
STEEL ANGLE
SLOPE
11 3/4"
GROUND FLOOR
100'-0"
171819
T.O. PARAPET
119'-4"
ENVELOPE 6 ENVELOPE 4
INSPECTION ONLY AREA
LINE OF AIR BARRIER
AIR BARRIER LEGEND
A. THE CONTRACTOR SHALL REFER TO
SPECIFICATIONS SECTION 07 05 23 AND 07 27 10.00
10 FOR ALL AIR BARRIER SYSTEM AND TESTING
REQUIREMENTS.
B. THE CONTRACTOR SHALL REFERENCE WALL
SECTIONS AND DETAILS THAT GRAPHICALLY
INDICATE THE VISUAL PLANE OF THE INTENDED
CONTINUOUS AIR BARRIERS. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL
INTENDED CONTINUOUS AIR BARRIERS ARE IN
PLACE PRIOR TO TESTING.
C. THE CONTRACTOR SHALL JOIN AND SEAL THE AIR
BARRIER MATERIAL OF EACH MATERIAL OF
ADJACENT ASSEMBLIES ALLOWING FOR THE
RELATIVE MOVEMENT OF THESE ASSEMBLIES AND
COMPONENTS.
D. THE CONTRACTOR SHALL MAKE ALL PENETRATIONS
AIRTIGHT AT AIR-BARRIER LOCATIONS INCLUDING
OPENINGS AT OR AROUND ELECTRICAL BOXES,
CONDUIT, PLUMBING, AND OTHER ASSEMBLIES.
E. CONTRACTOR SHALL FILL ALL GAPS AT DISSIMILAR
MATERIALS WITH SPRAY-FOAM INSULATION WHERE
NOT SPECIFICALLY DETAILED.
AIR BARRIER NOTES
AIR BARRIER SUMMARY -
BID OPTION 1
ENVELOPE 4
FLOOR AREA:
WALL AREA:
ROOF AREA:
TOTAL:
ENVELOPE 6
CALCULATIONS LOCATED ON
SHEET A-003
1,674 SF
2,655 SF
1,674 SF
6,003 SF
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021N
N
PROJECT
KEYPLAN
A
PLAN TRUE
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:23 :37 PM
COMPOSITE FLOOR PLAN,
ROOF PLAN, ELEVATIONS,
WALL SECTION & DETAILS - BID
OPTION 1
A-701
JMI
JRT/JBC
JBC
SCALE: 1/8" = 1'-0"
COMPOSITE FLOOR PLAN - BID OPTION 1D1
SCALE: 1/16" = 1'-0"
NORTH ELEVATION - BID OPTION 1C1
SCALE: 1/16" = 1'-0"
WEST ELEVATION - BID OPTION 1B1
SCALE: 1/16" = 1'-0"
EAST ELEVATION - BID OPTION 1A1
SCALE: 1/8" = 1'-0"
COMPOSITE ROOF PLAN - BID OPTION 1D3
SCALE: 1/8" = 1'-0"
BUILDING SECTION - BID OPTION 1C4
SCALE: 3/4" = 1'-0"
WALL SECTION - BID OPTION 1A3SCALE: 1 1/2" = 1'-0"
SECTION DETAILA2
SCALE: 1 1/2" = 1'-0"
SECTION DETAILB2
0 8' 16' 32'
1/16" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
6" 1'-6"1'0
1 1/2" = 1'-0"
SCALE: 1/8" = 1'-0"
AIR BARRIER SECTION - BID OPTION 1B4
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
PAINT/SAND/MIX
ELEC
DIRTY VEST
WASH BAY
128142
133 140
139A
137A
134A
131A
144B* 144C*
DIRTY ROOM
144.2
CLEAN ROOM
144.1
144.1*
144.2*
AIR SHOWER
144.3
EXTENTS OF PAINT BOOTH
PAINT/SAND/MIX
1.A.01 TYPE 3
ELEC
DIRTY VEST
WASH BAY
DIRTY ROOM
144.2
1.A.04 TYPE 2
1.A.03 TYPE 2
CLEAN ROOM
144.1
1.A.05 TYPE 6
1.A.06 TYPE 2
1.A.07 TYPE 12
1.A.08 TYPE 2
AIR SHOWER
144.3
EQ10 EQ4
EQ11
EQ12
EXTENTS OF PAINT BOOTH
GENERAL NOTES
A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD
BE CONSIDERED AS COMPLEMENTARY TO THE
CONSTRUCTION DOCUMENTS AS A WHOLE. ANY
QUESTIONS OR CONFLICTS SHOULD BE BROUGHT
TO THE ARCHITECTS ATTENTION.
B. PROVIDE A SMOOTH TRANSITION BETWEEN
DIFFERENT FLOOR MATERIALS.
C. REFER TO A-602 FINISH MATERIALS SCHEDULE FOR
MATERIAL MANUFACTURER AND COLOR.
D. REFER TO COMPOSITE INTERIOR SIGNAGE PLAN
B1/A-702 FOR FURNITURE, FIXTURES AND
EQUIPMENT.
INTERIOR FINISH
ABBREVIATION LEGEND
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISHED FLOOR
CPT CARPET TILE
GYP BD GYPSUM WALL BOARD
ESD ELECTROSTATIC DISSIPATIVE TILE
EXP EXPOSED
FRP FIBERGLASS REINFORCED PLASTIC
FRRF FUEL RESTISTIVE RESINOUS FLOORING
GT GLASS TILE
PCT PORCELAIN CERAMIC TILE
PTB PORCELAIN TILE BASE
PT PAINT
PLAM PLASTIC LAMINATE
RB RESILIENT BASE
RSF RUBBLER SHEET FLOORING
RS ROLLER SHADES
SC SEALED CONCRETE
SSM SOLID SURFACE MATERIAL
TP TOILET PARTITION
WD WOOD
WOC WALK-OFF TILE
WS WINDOW SHADE
X.X.XX TYPE X
FLOOR LEVEL
SECTOR (MAY BE A # OR LETTER)
SIGN NUMBER
SIGN TYPE
SIGNAGE LEGEND
D O
O R
H
EI
G H
T
DOOR WIDTH
SFB STEEL, 90-MIN FR
D O
O R
H
EI
G H
T
DOOR WIDTH
OCDX OVERHEAD COILING DOOR, EXT
D
O O
R H
EI
G
H T
DOOR WIDTH
SGX STEEL, EXT
GLAZING
REF DOOR
SCHEDULE
FOR TYPE
S4 STEEL
D O
O R
H
EI
G H
T 4"
2" 2"DOOR WIDTH
D2 STEEL
D O
O R
H
EI
G H
T 2"
2" 2"DOOR WIDTH
SHEET NOTES
1. INTEGRATED 4"H FRRF COVE BASE AT ALL WALLS.
PAINT/SAND/MIX
DIRTY ROOM
144.2
CLEAN ROOM
144.1
110'-6" AIR SHOWER
144.3
111'-6"
2' x 4' FIXTURE - EMERGENCY
EXIT SIGNS
WALL MTD EXTERIOR LIGHT
SUPPLY AIR DIFFUSERS
RETURN AIR GRILLES
1' x 4' FIXTURE - EMERGENCY SUSPENDED
2' x 4' FIXTURE
1' x 4' FIXTURE - SUSPENDED
WALL MTD EXTERIOR LIGHT - EMERGENCY
ACCESS DOORS
TYPICAL CEILING LEGEND
RCP NOTES
A. ALL CEILING SHALL BE 9' - 0" AFF UNLESS NOTED
OTHERWISE.
B. DOWNLIGHTS, WHERE PROVIDED, SHALL BE
CENTERED IN ACOUSTICAL TILE, UNLESS NOTED
OTHERWISE.
C. PROVIDE CONTROL JOINTS IN GYPSUM BOARD
CEILINGS AS REQUIRED IN THE SPECIFICATIONS.
2' x 2' CEILING GRID MOISTURE RESISTANT
GYP BD CEILING
GYP BD CEILING WITH FRP
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021N
N
PROJECT
KEYPLAN
A
PLAN TRUE
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:24 :00 PM
FLOOR FINISH PLAN, ROOM
FINISH SCHEDULE- BID OPTION
A-702
JBC/TDB
JRT/JBC/TLW
JDB/MP
SCALE: 1/8" = 1'-0"
COMPOSITE FLOOR FINISH PLAN - BID OPTION 1C1
ROOM FINISH SCHEDULE - BID OPTION 1
ROOM
NUMBER ROOM NAME
FLOOR
FINISH BASE FINISH
WALL FINISHES
CEILING FINISH CEILING HEIGHT NOTESNORTH SOUTH EAST WEST
144 PAINT/SAND/MIX FRRF FRRF PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK 1
144.1 CLEAN ROOM FRRF FRRF FRP2 FRP2 FRP2 FRP2 GYP BD / FRP2 11'-6" 1
144.2 DIRTY ROOM FRRF FRRF PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK 1
144.3 AIR SHOWER FRRF FRRF PT-1 PT-1 PT-1 PT-1 GYP BD / PT-5 10'-6" 1
SCALE: 1/8" = 1'-0"
COMPOSITE INTERIOR SIGNAGE & FURNITURE PLAN - BID OPTION 1B1
INTERIORS SIGNAGE SCHEDULE -BID OPTION 1
SIGN
NUMBER
SIGN
TYPE ROOM NO. ROOM NAME ON DRAWING MESSAGE TEXT (ENGLISH) NOTES
1.A.01 TYPE 3 144 PAINT/SAND/MIX EXIT RE: DETAIL D3/IG-500
1.A.03 TYPE 2 144.1 CLEAN ROOM DIRTY RE: DETAIL D2/IG-500
1.A.04 TYPE 2 144.2 DIRTY ROOM CLEAN RE: DETAIL D2/IG-500
1.A.05 TYPE 6 144 PAINT/SAND/MIX EXTINGUISHER RE: DETAIL C4/IG-500
1.A.06 TYPE 2 144.3 AIR SHOWER PAINT/SAND/MIX RE: DETAIL D2/IG-500
1.A.07 TYPE 12 144.3 AIR SHOWER RE: DETAIL A3/IG-500
1.A.08 TYPE 2 144.3 AIR SHOWER AIR SHOWER RE: DETAIL D2/IG-500
BID OPTION DOOR SCHEDULE
MARK
DOOR
FIRE
RATING STC
FRAME
NOTES
SIZE DOOR
TYPE TYPE
DETAIL
WD HGT THK HEAD JAMB SILL
144.1* 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN
144.2* 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN
144.2B* 6'-4" 7'-0" 3/4" - - - FABRIC ROLLING DOOR
144.3* 4'-0" 7'-0" 1 3/4" SFB
144A* 4'-0" 7'-0" 1 3/4" SFB
144B* 3'-0" 7'-0" 1 3/4" SGX S4
144C* 12'-0" 12'-0" 3/4" - - -
SCALE: 1/2" = 1'-0"
DOOR TYPES
SCALE: 1/2" = 1'-0"
FRAME TYPES
0 4' 8' 16'
1/8" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
TOILET ACCESSORIES - BID OPTION 1
CODE DESCRIPTION LOGISTICS CATEGORY
A6 PAPER TOWEL DISPENSER, TOUCH-FREE
AUTOMATIC
GF/CI
A19 INDUSTRIAL SOAP DISPENSER GF/CI
SCALE: 1/8" = 1'-0"
COMPOSITE REFLECTED CEILING PLAN - BID OPTION 1A1
FURNITURE & EQUIPMENT SCHEDULE - BID OPTION 1
FURNITURE & EQUIPMENT SCHEDULE
CODE DESCRIPTION
EQ4 FULL SIZE REFRIGERATOR W/ ICE & WATER
EQ10 FREEZER
EQ11 DOWNDRAFT MULTI-SLOTTED VENT TABLE
EQ12 DOWNDRAFT SLOTTED VENT TABLE
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
WEAPONS
TRAINING
CLASSROOM
RR W
RR M
SHARED
OFFICE
VEST
FUEL MAINT.
GENERAL
STORAGE
FUEL OPEN
OFFICE
OFFICE
FUEL
SUPERVISOR
WING
WEAPONS
MGR
OFFICE
BREAK/
TRAINING
VINYL OPEN
OFFICE
VEST
MATCHLINE
SEE A1 /
IN-102
MATCHLINE
SEE A1 /
IN-102
TILE PATTERN 'C'
EQ EQ EQ EQ
ALIGN
CORNERS
ALIGN
ALIGN
ALIGN
PT-2
PT
-2
PT-2
PT
-2
PT
-2
PT
-2
PT
-2
PT-2
PT
-2
T O
EN
D
OF
W
AL
L
PT
-2
GENERAL NOTES
A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD
BE CONSIDERED AS COMPLEMENTARY TO THE
CONSTRUCTION DOCUMENTS AS A WHOLE. ANY
QUESTIONS OR CONFLICTS SHOULD BE BROUGHT
TO THE ARCHITECTS ATTENTION.
B. REFER TO FINISH PLAN SHEETS (IN101 THROUGH
IN102) FOR EXTENTS OF WALL FINISHES.
C. REFER TO FINISH PLAN SHEETS (IN101 THROUGH IN
102) FOR FLOORING INSTALLATION PATTERN.
D. REFER TO INTERIOR FINISH DETAILS SHEET IN-103
FOR WALL TILE PATTERNS.
E. PROVIDE A SMOOTH TRANSITION BETWEEN
DIFFERENT FLOOR MATERIALS.
F. ALL WINDOW SILLS SHALL BE SOLID SURFACE
MATERIAL, SSM-2, UNLESS NOTED OTHERWISE.
G. CENTER FLOORING IN ROOM U.N.O. ON FINISH
PLAN.
H. DO NOT INSTALL TILE LESS THAN 3". CONFIRM
WITH ARCH. PRIOR TO INSTALLATION.
I. REFER TO FINISH MATERIALS SCHEDULE AE-602
FOR MATERIAL MANUFACTURER AND COLOR.
J. REFER TO INTERIOR ELEVATIONS FOR WALL
FINISH/DESIGN INTENT & ENLARGED PLANS.
K. THERE SHALL BE NO EXPOSED TILE EDGES, USE
SCHLUTER TRIM AS INDICATED, TO FINISH ALL
EDGES. SEE DETAILS (SHEET IN-103)
FINISH LEGEND
CPT-1: CARPET TILE
PCT-2: PORCELAIN TILE
SC1: SEALED CONCRETE
WOC1: WALK OFF TILE
PCT-3: PORCELAIN TILE
FFRF: FIVE COAT FUEL RESISTIVE
RESINOUS FLOORING
ESD: ELECTROSTATIC
DISSIPATIVE TILE
SC2: SEALED CONCRETE
CPT-2: CARPET TILE
PCT-1: PORCELAIN TILE
RSF: RESILIENT SHEET
FLOORING
PCT-4: PORCELAIN TILE
TS1 - CPT TO PCT, WOC TO PCT
SCHIENE, SATIN ANODIZED ALUMINUM
PROVIDE LEVELER TO BRING BOTH FINISHES TO THE
SAME LEVEL.
TS2 - PCT TO FRRF, PCT TO RSF
RENO-RAMP, SATIN ANODIZED ALUMINUM
TS3 - RSF TO FRRF, RSF TO SC
VINPRO-U, SATIN ANODIZED ALUMINUM
TS4 - RSF TO WOC
VINPRO-S, SATIN ANODIZED ALUMINUM
TS5 - FRRF TO WOC
RENO-RAMP, SATIN ANODIZED ALUMINUM
TS6 - PCT FLOOR TO PCT WALL
DILEX-AHK,SATIN ANODIZED ALUMINUM
TRANSITION LEGEND
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021N
N
PLAN TRUE
C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N
C hapm an9285M .rvt
12/22/2021 4:22 :44 PM
PARTIAL FLOOR FINISH PLAN -
SECTOR ONE
IN-101
JBC/TDB
TLW
JBC/MP
SCALE: 1/8" = 1'-0"
PARTIAL FLOOR FINISH PLAN - SECTOR ONEA1
0 4' 8' 16'
1/8" = 1'-0"
PROJECT
KEYPLAN
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
FIRE
MECH
JAN
117B
FUEL
ELEC
WASH
TOOLS
WASH BAY
ELEC
COMM
CLEAN M RR
DIRTY LR M
DIRTY VEST
DIRTY LR W
CLEAN W RR
CORR
120B
VEST
FUEL CELL
VEST
120A
MOTHER'S
ROOM
117A
MATCHLINE
SEE A1 /
IN-101
MATCHLINE
SEE A1 /
IN-101
B4
IN-102
TILE PATTERN 'C'
CLEAN W LR
CLEAN M LR
MASK
WASHING
DIRTY LR M
DIRTY VEST
DIRTY
SHOWER M
DIRTY
SHOWER M
CLEAN
SHOWER M
CLEAN
SHOWER W
DIRTY
SHOWER W
DIRTY RR
UNISEX
DIRTY LR W
CLEAN W RR
CLEAN M RR
CLEAN W LR
137CLEAN M LR
CORR
120B
TILE PATTERN 'C'
MASK
WASHING
GENERAL NOTES
A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD
BE CONSIDERED…