ATTACHMENT 1b - FSB2020-270-00 - WI-ANG - 3-Bay Hangar - ADD 01 COMBINED DRAWINGS (2 of 2).pdf

PDF 28 MB Posted

Attached to
F-35 THREE BAY SPECIALIZED HANGAR
Solicitation number
W50S9F-22-B-0001
Issued by

About this file

This solicitation is for the construction of a new three-bay hangar at Dane County Regional Airport in Madison, Wisconsin. The project involves demolishing an existing 19,875 square foot building and constructing a new 31,000 square foot three-bay hangar to support the F-35 mission. Scope of work includes pre-conditioned aircraft air, 270VDC power, fire suppression, HVAC, administrative and shop spaces, a lightning protection system, fall protection, and an Advantor security system. The contract will be a single award fixed-price construction contract issued by the Department of the Army National Guard. The base bid is for hangar construction with options for a paint/mix addition and aircraft-rated pavement. The bid opening will be conducted on SAM.gov. Interested contractors must register in SAM and check the website for any amendments. The projected value is between $25-100 million and the contract duration is 550 days from notice to proceed. The NAICS code is 236220 for commercial and institutional building construction.

View the file

Other files

File Type Posted
Bid Opening Attendance Sheet.pdf PDF
Abstract of Offers.pdf PDF
Questions and Answers 4.pdf PDF
39_ITEM 01.5-1_ADD 03_Bid Question Attachment_2022.06.14.pdf PDF
Question and Answer Set 4_Question 2_Custom Graphic.pdf PDF
W50S9F22B0001 Solicitation - Amend 0004.pdf PDF
22_ITEM 01.3-12_ADD 04_02700A-502.pdf PDF
19_ITEM 01.3-9_ADD 04_02700A-002.pdf PDF
00_FSB2020-270-00_WI-ANG_3-Bay_ADD NO. 04_2022.06.28_Narrative.pdf PDF
24_ITEM 01.3-14_ADD 04_02700A-702.pdf PDF
Questions and Answers 3.pdf PDF
25_ITEM 01.3-15_ADD 04_02700ES101.pdf PDF
10_ITEM 01.2-10_ADD 04_Section 32 13 14.13.pdf PDF
26_ITEM 01.3-16_ADD 04_02700EP102.pdf PDF
20_ITEM 01.3-10_ADD 04_02700A-140.pdf PDF
01_ITEM 01.2-1_ADD 04_PROJECT TOC.pdf PDF
15_ITEM 01.3-5_ADD 04_02700SF105.pdf PDF
23_ITEM 01.3-13_ADD 04_02700A-503.pdf PDF
03_ITEM 01.2-3_ADD 04_Section 07 21 13.pdf PDF
05_ITEM 01.2-5_ADD 04_Section 08 33 13.pdf PDF
07_ITEM 01.2-7_ADD 04_Section 09 90 00.pdf PDF
18_ITEM 01.3-8_ADD 04_02700SF504.pdf PDF
11_ITEM 01.3-1_ADD 04_02700C-301.pdf PDF
06_ITEM 01.2-6_ADD 04_Section 08 33 23.pdf PDF
09_ITEM 01.2-9_ADD 04_Section 11 94 00.01.pdf PDF
27_ITEM 01.3-17_ADD 04_02700EP701.pdf PDF
04_ITEM 01.2-4_ADD 04_Section 07 24 00.pdf PDF
16_ITEM 01.3-6_ADD 04_02700SF106.pdf PDF
28_ITEM 01.3-18_ADD 04_02700EP702.pdf PDF
14_ITEM 01.3-4_ADD 04_02700SF104.pdf PDF
17_ITEM 01.3-7_ADD 04_02700SF503.pdf PDF
02_ITEM 01.2-2_ADD 04_Section 04 20 00.pdf PDF
12_ITEM 01.3-2_ADD 04_02700C-401.pdf PDF
08_ITEM 01.2-8_ADD 04_Section 11 94 10.pdf PDF
21_ITEM 01.3-11_ADD 04_02700A-501.pdf PDF
13_ITEM 01.3-3_ADD 04_02700C-601.pdf PDF
FSB2020-270-00 - WI-ANG - 3-Bay Hangar - Addendum 004 COMBINED DRAWINGS.pdf PDF
W50S9F22B0001 Solicitation - Amend 0003.pdf PDF
28_ITEM 01.3-18_ADD 03_02700A-600.pdf PDF
24_ITEM 01.3-14_ADD 03_02700A-501.pdf PDF
01_ITEM 01.2-1_ADD 03_Section 02 65 00.pdf PDF
14_ITEM 01.3-4_ADD 03_02700C-402.pdf PDF
20_ITEM 01.3-10_ADD 03_02700A-002.pdf PDF
05_ITEM 01.2-5_ADD 03_Section 08 71 00.pdf PDF
Questions and Answers 2.pdf PDF
07_ITEM 01.2-7_ADD 03_Section 21 13 13.pdf PDF
FSB2020-270-00 - WI-ANG - 3-Bay Hangar - Addendum 003 Combined Drawings.pdf PDF
18_ITEM 01.3-8_ADD 03_02700SF103.pdf PDF
16_ITEM 01.3-6_ADD 03_02700C-601.pdf PDF
03_ITEM 01.2-3_ADD 03_Section 05 50 13.pdf PDF
Show 40 more

Latest 50 of 147 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RUNNER CHANNEL

SCHEDULED FRAME

SCHEDULED DOOR

EXTEND GYP BD @

RATED PARTITION

PARTITION TYPE

PER FLOOR PLANS

RE: FLOOR PLANS

PARTITION

CONT SEALANT,

BOTH SIDES

EQ EQ

CONT SEALANT, BOTH SIDES HM FRAME

DOUBLE JAMB STUDS AT ALL

JAMBS (CLIP TOGETHER AT

12" OC VERT)

JAMB ANCHORS,

3 PER JAMB MIN.

PERPENDICULAR

PARTITION PER PLAN

R E:

F

LO

O R

P

LA

N S

PA

R

TI

TI

O N

LOW EXPANSION FOAM FILL

SCHEDULED DOOR

SCHEDULED DOOR,

PROVIDE 1/2" UNDERCUT

SCHEDULED

FRAME BEYOND

4" 1" 1/2"

EDGE OF FOUNDATION

PROVIDE ALUMINUM

OFFSET SADDLE

THRESHOLD OR

APPROVED EQUAL.

INSTALL IN FULL BED

OF SILICONE SEALANT

OFFSET T.O. SIDEWALK 1/4"

FROM T.O. FOUNDATION

EXPANSION MATERIAL

1/ 2"1/

4" 1/

4"

SLOPE

PROVIDE INVERTED ALUMINUM

DOOR SHOE WITH RAIN DRIP

OR APPROVED EQUAL

TERMINATE

FLOORING AT

THRESHOLD EDGE

LANDING 1:50 MAX

SIDEWALK 1:20 MAX

SCHEDULED DOOR

CMU BOND BEAM

EQ EQ

GROUT FILL

CONT SEALANT,

BOTH SIDES

RE: FLOOR PLANS

CMU

4"

HM FRAME

1"

HM FRAME

CMU

GROUT FILL

CONT SEALANT,

BOTH SIDES

SCHEDULED DOOR

FRAME ANCHORS,

3 PER JAMB MIN.

R E:

F

LO

O R

P

LA

N

C M

U

3/16" 2"

EQ

EQ

SCHEDULED DOOR

CMU BOND BEAM

GROUT FILL

CONT SEALANT,

BOTH SIDES

RE: FLOOR PLANS

CMU

4"

HM FRAME

3 5/8" 2" 4"

1'-5 1/4"

BRICK VENEER

THERMAL AIR

SPACE

RIGID INSUL.

1"6 X 10 X 5/16

LOOSE LINTEL

2 5/8" 8 3/4" 5 7/8"

PREFINISHED

METAL FLASHING

WEEPS

CAVITY MESH

HM FRAME

CMU

GROUT FILL

CONT SEALANT,

BOTH SIDES

SCHEDULED DOOR

FRAME ANCHORS,

3 PER JAMB MIN.

R E:

F

LO

O R

P

LA

N

C M

U 4"

2"

5/ 8"

GROUT FILL

THERMAL AIR SPACE

1' -5

/4

SPLIT FACE VENEER

4" RIGID INSUL.

5/

8"

3/ 4"

RUNNER CHANNEL

SCHEDULED FRAME

SCHEDULED DOOR

EXTEND GYP BD @

RATED PARTITION

PARTITION TYPE

PER FLOOR PLANS

4"

RE: FLOOR PLANS

PARTITION

CONT SEALANT,

BOTH SIDES

1"

SHEATHING

EIFS DRAINAGE BACKING

RIGID INSUL.

EIFS FINISH

3/4" PLYWOOD

MTL. STUD BOX HEADER

HEAD FLASHING

DRIP EDGE

AIR BARRIER

1'-1 1/4"

5/8" GYP. BD.

CONT SEALANT, BOTH SIDES

HM FRAME

DOUBLE JAMB STUDS AT ALL

JAMBS (CLIP TOGETHER AT

12" OC VERT)

JAMB ANCHORS,

3 PER JAMB MIN.

5/

8" 2"

4"

R E:

F

LO

O R

P

LA

N S

PA

R

TI

TI

O N

LOW EXPANSION FOAM FILL

SCHEDULED DOOR

SPLIT FACE VENEER

THERMAL AIR BARRIER

RIGID INSUL.

AIR BARRIER

3/4" PLYWOOD

1' -6

/8

1"

FINISHED SOFFIT

109'-0"

WOOD BLOCKING

BUILT UP 8" CFMF

BOX BEAM HEADER

CEILING AS SCHEDULED

METAL CHANNEL

BACKER ROD & SEALANT

BOTH SIDES

CURTAIN WALL SYSTEM

8" CFMF

5/8" GYP. BD. ON EA. SIDE

BACKER ROD & SEALANT

WOOD BLOCKING

METAL INSUL. SOFFIT

6" CFMF

3/4" PLYWD.

PLYWOOD BLOCKING

AIR BARRIER

BREAK MTL FLASHING

1"

RE: FLOOR PLANS

SOLID SURFACE SILL W/

EASED EDGES, RE:

INTERIORS A-602

SCHEDULED WINDOW

INSULATION

GYP BD

SPLIT FACE VENEER

CAST STONE COPING

EIFS BEYOND

MTL FLASHING W/ END DAMS

BACKER ROD & SEALANT

EA. SIDE

AIR BARRIER

RIGID INSUL.

PLYWOOD

SHEATHING

CONT L3X3X3/16 GALV

ANGLE ATTACHED

TO TO STUDS WITH 2 #10

TEK SCREWS AT 16" O.C.

1"

0°

1/2"

BACKER ROD & SEALANT

EA. SIDE

SCHEDULED DOOR

EIFS

AIR BARRIER

SOLID SURFACE SILL

RE: INTERIORS A-602

INSULATION

8" CFMF

GYP. BD.

PLYWOOD SHEATHING

PLYWOOD BLOCKING

R E:

F

LO

O R

P

LA

N S

1/ 2" 1

EIFS ON 4" INSUL.

AIR BARRIER

MTL. STUD BOX HEADER

PLYWOOD SHEATHING

8"CFMF

INSULATION

GYP BD

METAL FLASHING

DRIP EDGE

CURTAIN WALL

BACKER ROD & SEALANT

EA. SIDE

RE: FLOOR PLANS

SUN SHADE

1/2"1/2"

SOLID SURFACE ON

EA SIDE

12" CMU WALL

SCHEDULED WINDOW

SHIM & CAULK

EQ

EQ

SHIM & CAULK

SCHEDULED WINDOW

SOLID SURFACE BELOW

12" CMU WALL

12" CMU WALL

SCHEDULED WINDOW

SHIM AND CAULK

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\gaz\D o cum ents\02700_Arch_G Zalabak Z5W

7D .rvt

4/20/2022 11:22 :40 AM

DETAILS

A-500

JMI

BDR

JBC

SCALE: 3" = 1'-0"

HEAD DETAILD1

SCALE: 3" = 1'-0"

JAMB DETAILC1

SCALE: 3" = 1'-0"

SILL DETAILB1

SCALE: 3" = 1'-0"

HEAD DETAILD2

SCALE: 3" = 1'-0"

JAMB DETAILC2

3" 9"6"0

3" = 1'-0"

SCALE: 3" = 1'-0"

HEAD DETAILD3

SCALE: 3" = 1'-0"

JAMB DETAILC3

SCALE: 3" = 1'-0"

HEAD DETAILD4

SCALE: 3" = 1'-0"

JAMB DETAILC4

SCALE: 3" = 1'-0"

CURTAIN WALL HEAD DETAILA1

SCALE: 1 1/2" = 1'-0"

CURTAIN WALL SILL DETAILB2 SCALE: 1 1/2" = 1'-0"

CURTAIN WALL JAMB DETAILB3 SCALE: 1 1/2" = 1'-0"

CURTAIN WALL HEAD DETAILB4

SCALE: 1 1/2" = 1'-0"

WINDOW SILL DETAILA2 SCALE: 1 1/2" = 1'-0"

WINDOW JAMB DETAILA3 SCALE: 1 1/2" = 1'-0"

WINDOW HEAD DETAILA4

6" 1'-6"1'0

1 1/2" = 1'-0"

1 ADDENDUM 1 04/22/2022

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

OKLAHOMA CITY

OK

OVERHEAD

COILING DOOR

OVERHEAD COILING

DOOR JAMB GUIDES

OVERHEAD COILING

DOOR HOOD

CMU BOND BEAM

RE: FLOOR PLANS

CMU

OVERHEAD COILING

DOOR JAMB GUIDES

STEEL ANGLE

BY MANF.

OVERHEAD

COILING DOOR

CMU

R E:

F

LO

O R

P

LA

N

C M

U

EXPANSION

ANCHOR BOLT

CMU BOND BEAM

OVERHEAD DOOR HOOD

HEADPLATE BEYOND

OVERHEAD DOOR

OVERHEAD DOOR

JAMB GUIDES

RE: FLOOR PLANS

CMU

CONT SEALANT, BOTH SIDES

DOUBLE JAMB STUDS TYP

AT ALL JAMBS (CLIP

TOGETHER AT 12" OC VERT)

ALUMINUM

WINDOW

SYSTEM

R E:

F

LO

O R

P

LA

N S

PA

R

TI

TI

O N

2" 4 1/2"

1/

2"

6"

3/8" 2"

HEAD/SILL

INSULATED

OUTSIDE GLAZING

JAMB

INSULATED

OUTSIDE GLAZING

HEAD/JAMB/SILL

INT 1/4" GLZ

SHIM AS REQUIRED

@ EXT: LOW EXPANSION FOAM FILL

IN PERIMETER FRAME JOINT CAVITY

@INT: SHIM AS REQUIRED

FABRIC HANGAR DOOR

WEATHER TIGHT SEAL

PROVIDED BY FABRIC DOOR

MFR

MFR

EXTRUSION

VERTICAL

INSULATED METAL

WALL PANEL

INSULTED METAL

SOFFIT PANEL

CFMF

CFMF

CHANNEL

DOOR CLEAR HEIGHT

121'-8 1/2"

6'

1/

2"

GROUND FLOOR

100'-0"

PAVING (REFER TO CIVIL)

SLAB OF GRADE

WITH RIDGE AT

CENTER OF DOOR

FABRIC HANGAR DOOR

FLOOR SEAL WITH

SAFETY EDGE

1/4" / 1'-0"1/4" / 1'-0"

SCHEDULED WINDOW

SHIM & CAULK

SCHEDULED FLOOR

CONC. FLOOR SLAB

SHIM & CAULK

SCHEDULED WINDOW

GYP BD

PLYWOOD BLOCKING

6" CFMF W/ SOUND BATT

INSUL.

6" CFMF W/ SOUND

BATT INSUL.

SCHEDULED WINDOW

6" CFMF BOX BEAM

PLYWOOD BLOCKING

GYP BD

SHIM AND SEALANT

5/8" GYP BD

(2 LAYERS)

FIRE SEALANT

6" CH STUD

6" CHANNEL

BEAM

ANGLE

8" BOND BEAM

1" SHAFT

LINER

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:24 :49 PM

DETAILS

A-501

JMI

BDR

JBC

SCALE: 3" = 1'-0"

HEAD DETAILD2 SCALE: 3" = 1'-0"

JAMB DETAILD3SCALE: 3" = 1'-0"

HEAD DETAILD1

SCALE: 3" = 1'-0"

STOREFRONT, HEAD, JAMB, SILL DETAILSA3

SCALE: 1 1/2" = 1'-0"

HEAD DETAILB1

SCALE: 1 1/2" = 1'-0"

SILL DETAILA1 3" 9"6"0

3" = 1'-0"

6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE: 1 1/2" = 1'-0"

WINDOW SILL DETAILB3 SCALE: 1 1/2" = 1'-0"

WINDOW JAMB DETAILB4 SCALE: 1 1/2" = 1'-0"

WINDOW HEAD DETAILB5

SCALE: 1 1/2" = 1'-0"

SECTION DETAILA5

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

GROUND FLOOR

100'-0"

SCHEDULED GLAZING

SHIM AND SEALANT

BACKER ROD

AND SEALANT

PAVING, REFER

TO CIVIL

SLAB ON GRADE

ROOF FRAMING

115'-0"

STEEL

STRUCTURE

ROOF

MEMBRANE

6" ROOF

INSULATION

(R-30)

STEEL DECK

5/8" SHEATHING ON

EA SIDE

ROOF PROTECTION

BOARD

DEFLECTION TRACK

8" CFMF

A.3

SHIM TRACK

13 ROOF

MEMBRANE

6" ROOF

INSULATION

(R-30)

STEEL

DECK

2 LAYERS 5/8"

GYP. BD.

CH STUD

STEEL BEAM

DEFLECTION

TRACK

1" SHAFT LINER

BATT

INSULATION

(R-25)

ROOF

PROTECTION

BOARD

STEEL COLUMN

+/- 9 1/4" +/- 9 1/4"

GROUND FLOOR

100'-0"

ONE HOUR

RATED 8"

CMU

1' -4

SLAB ON

GRADE

FOOTING

8" 8"

SCHEDULED

BASE

8" CMU BOND BEAM,

RE: STRUCTURAL

GROUND FLOOR

100'-0"

ONE HOUR

RATED 12"

CMU WALL

5/8" GYPSUM

WALLBOARD

8" BATT

INSULATION

(R-25)

8" CFMF

SLAB ON GRADE

PORCELAIN

WALL TILE

8" TRACK

FOOTING

SCHEDULED BASE

C

ADMIN ROOF

116'-8"

ROOF

MEMBRANE

6" ROOF

INSULATION

(R-30)

STEEL DECK

12" CMU

8" BATT

INSULATION

(R-25)

8" CFMF

5/8" GYPSUM

WALLBOARD

4" VERTICAL

INSULATED METAL

PANEL (R-32)

ROOF

PROTECTION

BOARD

8" TRACK

TURN MEMBRANE

UP PANEL (SIM

D5/AE-502)

CFMF

INFILL AT

16" O.C.

FASTNER

EXPANSION

JOINT (EJ-2)

FLEXIBLE

FLASHING

FT WOOD

BLOCKING

STEEL ANGLE

STEEL

STRUCTURE

STEEL CHANNEL

VAPOR

BARRIER

1'-2"

10"

8" CMU GROUT

FILLED

CAST STONE

COPING

4" SPLIT

FACED CMU

4" CAVITY WALL

INSULATION (R-15)

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

BACKER ROD

& SEALANT

STEEL CHANNEL

STEEL COLUMN

L3X3X3/16 STEEL

ANGLE CONT GALV

W/ DIA POST

INSTALLED

ANCHOR AT 24" OC

BACKER ROD

& SEALANT

PERIMETER

ANGLE

1"

PREFINSIHED

METAL FLASHING

GROUND FLOOR

100'-0"

ONE HOUR

RATED 8" CMU

WALL

4" CAVITY WALL

INSULATION

(R-15)

4" CMU SPLIT-FACED

FLUID APPLIED

AIR BARRIER

PRE-FINISHED

METAL FLASHING

WEEP

CONCRETE CURB

MORTAR NET

PAVEMENT

(REFER CIVIL)

REFER PLANS

BACKER ROD &

SEALANT

TRANSLUCENT

PANELS (R-12.5)

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

STEEL CHANNEL

INSTALL PANELS

PER MFG SPECIFICATIONS

STEEL COLUMN

STEEL ANGLE

TRANSLUCENT

PANELS

(R-12.5)

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

STEEL CHANNEL

STEEL COLUMN

INSTALL PANELS

PER MFG SPECIFICATIONS

STEEL ANGLE

1'-4" 10"

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

EXTEND ROOF

MEMBRANE UP &

OVER PARAPET

6" ROOF

INSULATION

(R-30)

STEEL DECK

ROOF

PROTECTION

BOARD

PRE-FINISHED

METAL PARAPET

CAP

WOOD

BLOCKING

TAPERED

INSULATION

8" BATT

INSULATION

(R-25)

STEEL

STRUCTURE

EXTERIOR

SHEATHING

FT WOOD

BLOCKING

STEEL ANGLE

2'-2"

SLOPE

BATT

INSULATION

(R-25)

EXTERIOR

GYPSUM

WALLBOARD

EXTERIOR

INSULATION AND

FINISH SYSTEM

(E.I.F.S.) (R-16)

8" CFMF

EXTERIOR

SHEATHING

PRE-FINISHED

METAL

PARAPET CAP

EXTEND ROOF

MEMBRANE UP &

OVER PARAPET

WOOD

BLOCKING

6" ROOF

INSULATION

(R-30)

STEEL DECK

VAPOR BARRIER

ROOF

PROTECTION

BOARD

T.O. PARAPET

119'-4"

STEEL

STRUCTURE

COMPRESSION

BAR

FT WOOD

BLOCKING

STEEL ANGLE

SLOPE

1'-2" TYP.

GROUND FLOOR

100'-0"

EDGE OF SLAB

CAVITY WALL

INSULATION (R-15)

8" CFMF

BATT INSULATION (R-25)

5/8" GYP. BD.

EXTERIOR SHEATHING

FLUID APPLIED AIR

BARRIERWEEP

4" CMU

SPLIT FACE

SCHEDULED BASE

8" TRACK

8"

CAST STONE

COPING

PRE-FINISHED

METAL FLASHING

PAVEMENT

(REFER CIVIL)

GROUT FILL

GRAVEL FILL

MORTAR NET

MASONRY

WALL TIES

PREFINSIHED

METAL FLASHING

BACKER ROD

& SEALANT

REFER PLANS

CONT L3X3X3/16 GALV

ANGLE ATTACHED

TO TO STUDS WITH 2 #10

TEK SCREWS AT 16" O.C.

EXTERIOR

INSULATION AND

FINISH SYSTEM

(E.I.F.S.) (R-16)

BOND BREAKER

FINISHED SOFFIT

109'-0"

ROOF MEMBRANE OVER

PROTECTION BOARD

EDGE ANGLE

6" ROOF TAPERED

INSULATION (R-30)

PRE-FINISHED

METAL DRIP EDGE

HORIZONTAL

INSULATED METAL

PANELS - COLOR #2

MEMBRANE

FLASHING

CONTINUOUS

CLEAT

TREATED WOOD

BLOCKING

STEEL

CHANNEL

EXTERIOR

SHEATHING ON

CFMF

EXTERIOR

SHEATHING ON

CFMF

INSULATED METAL

PANELS - COLOR #2

M

IN

8"

COORDINATE

THROUGH WALL

FLASHING DETAIL

WITH PANEL MFR

PRE-FINISHED

METAL REGLET

AND COUNTER

FLASHING

ROOFING

MEMBRANE

TURNED UP

METAL PANEL

9'-1 1/4"

MFR

EXTRUSION BACKER ROD

& SEALANT,

EA. SIDECURTAINWALL

SYSTEM

CFMF BOX

BEAM

STEEL

STRUCTURE

WOOD

BLOCKING

CEILING AS

SCHED.

5/8" GYP BD

8" CFMF

BATT

INSULATION

SHIM AS

REQUIRED

TREATED WOOD

BLOCKING

STEEL DECK

SLOPE

T.O. PARAPET

119'-4"

4' -0

COMPRESSION

BAR

PRE-FINISHED METAL

PARAPET CAP

WOOD BLOCKING

VAPOR

RETARDER

6" ROOF

INSULATION (R-30)

ROOF PROTECTION

BOARD

EXTEND ROOF

MEMBRANE UP &

OVER PARAPET

STEEL DECK

ONE HOUR

RATED 8" CMU

8" CFMF

EXTERIOR

SHEATHING

BATT INSULATION

(R-25)

VAPOR

BARRIER

EXTERIOR

INSULATION AND

FINISH SYSTEM

(E.I.F.S.) (R-16)

STEEL ANGLE

SLOPE

J

METAL

DECK

6" ROOF

INSULATION

R(30)

ROOFING

MEMBRANE

OVER ROOF

PROTECTION

BOARD

WOOD

BLOCKING

EXPANSION

JOINT (EJ-1)

4" INSULATED

METAL PANEL

VERTICAL JOINT

(R-32)

ROOF MEMBRANE

COUNTER-

FLASHING

AIR BARRIER

STEEL

COLUMN

8" CMU

3-5/8" CFMF @

16" OC

VERTICALLY

COUNTER-

FLASHING

10"

EDGE ANGLE

SHEET METAL

CLOSURE

ATTACHED ONLY

TO CMU

FILL CAVITY

WITH BATT

INSULATION

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:23 :27 PM

DETAILS

A-502

JMI

JRT/JBC

JBC

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB3

SCALE: 1 1/2" = 1'-0"

SECTION DETAILC3

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB2

SCALE: 1 1/2" = 1'-0"

SECTION DETAILA2

SCALE: 1 1/2" = 1'-0"

SECTION DETAILC2

6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE: 1 1/2" = 1'-0"

SECTION DETAILD2

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB1

SCALE: 1 1/2" = 1'-0"

SECTION DETAILA1

SCALE: 1 1/2" = 1'-0"

SECTION DETAILC1B

SCALE: 1 1/2" = 1'-0"

SECTION DETAILC1A

SCALE: 1 1/2" = 1'-0"

SECTION DETAILD1

SCALE: 1 1/2" = 1'-0"

SECTION DETAILD3

SCALE: 1 1/2" = 1'-0"

SECTION DETAILA3

SCALE: 1 1/2" = 1'-0"

SECTION DETAILD5

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB5

SCALE: 1" = 1'-0"

SECTION DETAILA5

0 6" 1' 2'

1" = 1'-0"

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

8" CFMF

EXTERIOR INSULATION

AND FINISH SYSTEM

(E.I.F.S.) (R-16)

FLUID-APPLIED

MEMBRANE AIR

BARRIER

MANUFACTURED

ALUM CANOPY

1/2" EXTERIOR

GYPSUM SHEATHING

HANGAR ROD

8" CFMF BOX

BEAM

6'-0"

BACKER ROD AND

SEALANT

110' - 4"

BO CANOPY

BENT PLATE PAINTED TO

MATCH EIFS COLOR

8" CFMF BOX

BEAM

5/8" GYP BD

CFMF

1/2" EXTERIOR

GYPSUM

SHEATHING

EXTERIOR INSULATION

AND FINISH SYSTEM

(E.I.F.S.) (R-16)

BACKER ROD &

SEALANT

FLUID-APPLIED

MEMBRANE AIR

BARRIER

3/4"

1/2" EXTERIOR

GYPSUM SHEATHING

EXTERIOR

INSULATION AND

FINISH SYSTEM

(E.I.F.S.) (R-16)

FLUID-APPLIED

MEMBRANE AIR

BARRIER

NOTE: REVEAL DIMENSIONS ARE MEASURED TO

THE CENTERLINE OF THE REVEAL

3/4"

CL

3/ 4"

3/ 4"

3/ 4"

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:24 :54 PM

DETAILS

A-503

JBC

GAZ

GAZ

SCALE: 1 1/2" = 1'-0"

PRE-ENGINEERED METAL CANOPYA1

SCALE: 1 1/2" = 1'-0"

EIFS CONTROL JOINT DETAILC1

SCALE: 1 1/2" = 1'-0"

EIFS REVEAL JOINTB1

6" 1'-6"1'0

1 1/2" = 1'-0"

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

C

STEEL COLUMN

5/8" GYPSUM

WALLBOARD

4 1/2" CURTAIN

WALL SYSTEM

BATT

INSULATION

(R-25)

CAVITY WALL

INSULATION

(R-15)

4" SPLIT-FACED CMU

EXTERIOR

SHEATHING

6" METAL STUD 8" CFMF

WOOD

BLOCKING

B.7

6" CURTAIN

WALL SYSTEM

STEEL COLUMN

3/4" PLYWOOD

BLOCKING

5/8" GYP. BD ON 8" CFMF

1/ 2"

T

YP

*I6

CAST STONE

COPING ABOVE

FLUID APPLIED

AIR BARRIER

BACKER ROD &

SEALANT EA. SIDE

1"

AIR SPACE

BATT INSULATION (R-25)

5/8" GYPSUM WALLBOARD

WOOD BLOCKING

BACKER ROD &

SEALANT EA. SIDE

1'-9 1/4"

3/4" PLYWOOD

BLOCKING

AESS STEEL

COLUMN

6" CURTAIN

WALL SYSTEM

C.2

4.3

6" CURTAIN

WALL SYSTEM

STEEL

COLUMN

5/8" GYP ON

8" CFMF

6" CURTAIN

WALL SYSTEM

A6

8" METAL

STUD

BATT

INSULATION

(R-25)

CAVITY WALL

INSULATION (R-15)

EXTERIOR

SHEATHING

4" SPLIT-

FACED CMU

4.3

FLUID

APPLIED AIR

BARRIER

1/ 2"

T

YP

BACKER ROD & SEALANT

BOTH SIDES

3/4" PLYWOOD BLOCKING

8" CFMF

BACKER ROD &

SEALANT

1" M

IN

. 10

/2

M

6" CMU

CAVITY WALL

INSULATION

(R-15)

FLUID

APPLIED AIR

BARRIER

4" CMU

SPLIT FACE

BACKER ROD

AND SEALANT

SPRAY FOAM

INSULATION

STEEL TUBE

STEEL CHANNEL

(BY FABRIC

DOOR MFR)

1 3/4"

4'-9 1/2"

8" CMU

STEEL COLUMN

METAL PANEL

TYPICAL 1-3/8" AIR

SPACE AT ALL EXTERIOR

HANGAR WALLS

1'-5"

CLOSURE

TRIM PIECE

1'-3 1/2" 10"

1 1/2"

1'-5 3/4" 1'-3 1/2"

6" CMU

CAVITY WALL

INSULATION

(R-15)

FLUID

APPLIED AIR

BARRIER

4" CMU

SPLIT FACE

COLUMN

F2

CLOSURE

TRIM PIECE

METAL

PANEL

BACKER ROD

AND SEALANT

SPRAY FOAM

INSULATION

INSULATED

METAL PANEL

CAST STONE

BELOW

BATT

INSULATION

(R-25)

J

EXPANSION

JOINT (EJ-2)

STEEL TUBE

STEEL

CHANNELS (BY

FABRIC DOOR

MFR)

3/

4"

1' -5

2-1/2" METAL

STUD

5/8" GYP BD

8" METAL STUD

8" CMU

10"

1 HR. RATED

CMU WALL

A6

CURTAIN WALL

SYSTEM

1" MIN.

CAST STONE

COPING ABOVE

SPLIT FACE CMU

AIR SPACE

FLD APLD AIR

BARRIER

5/8" GYP. BD.

BATT INSULATION

5/8" GYP. BD.

10" CFMF

BACKER ROD &

SEALANT EA SIDE

EIFS FINISH

3/4" PLYWOOD BLKG.

8" CFMF

5/8" GYP. BD.

8" METAL STUD

10" METAL STUD

6" CFMF

6" METAL

STUD

G

COLUMN

CURTAIN WALL

SYSTEM

*M12C

RIGID INSUL.

AIR SPACE

4" CMU SPLIT FACE

CAST STONE COPING,

ABV.

8" CFMF

BATT INSUL.

(R-25)

5/8" GYP. BD.

BACKER ROD AND

SEALANT BOTH SIDES

3/4" PWD

BLOCKING

MIN.

1"

VAPOR

BARRIER

FLD APLD AIR BARRIER

1 HR. RATED 12" CMU

R

EF

ER

P

LA

N

4" CMU

SPLIT FACE

8" CMU

CAVITY

WALL

INSULATION

(R-15)

FABRIC DOOR WITH

WEATHER TIGHT SEAL

PROVIDED BY MANF

6' -5

9' -3

1'-5" 10"

8" 8"

FLUID

APPLIED AIR

BARRIER

FIRE RATED

EXPANSION

JOINT (EJ-2)

SPRAY FOAM

INSULATION

H

BACKER ROD

AND SEALANT

STEEL TUBE

STEEL CHANNEL (BY

FABRIC DOOR MFR)

FABRIC DOOR WITH

WEATHER TIGHT SEAL

PROVIDED BY MANF

STEEL CHANNEL (BY

FABRIC DOOR MFR)

STEEL TUBE

BACKER ROD AND SEALANT

SPRAY FOAM INSULATION

1 3/4"

1'-5"

TYPICAL 1-3/8" AIR

SPACE AT ALL

EXTERIOR

HANGAR WALLS

A-307 A4

3' -2

/2

3'

-2

/2

1 HR. RATED

CMU WALL

FIRE RATED

EXPANSION JOINT

(EJ-2)

J

8"

COLUMN

5/8" GYP BD ON

2-1/2" MTL STUDS

5/8" GYP BD ON

8" CFMF

COLUMN

FLUID

APPLIED AIR

BARRIER

EIFS

EXPANSION

JOINT (EJ-2)

CAST STONE

BELOW

EXTERIOR

SHEATHING

FLUID

APPLIED AIR

BARRIER

4" CMU SPLIT

FACE

CAVITY WALL

INSULATION

(R-15)

8" RATED CMU

TO EXTEND

10'-0" BEYOND

ADJACENT

WALL

10"

1 HR. RATED

CMU WALL

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:24 :44 PM

PLAN DETAILS

A-505

JBC/TDB

GAZ

GAZ

SCALE: 1 1/2" = 1'-0"

PLAN DETAILC1

SCALE: 1 1/2" = 1'-0"

PLAN DETAILB1 SCALE: 1 1/2" = 1'-0"

PLAN DETAILB2

SCALE: 1 1/2" = 1'-0"

PLAN DETAILA1

SCALE: 1 1/2" = 1'-0"

PLAN DETAILC3

SCALE: 1 1/2" = 1'-0"

PLAN DETAILB3

SCALE: 1 1/2" = 1'-0"

PLAN DETAILA3 SCALE: 1 1/2" = 1'-0"

PLAN DETAILA4 6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE: 1 1/2" = 1'-0"

PLAN DETAILD5

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

8" CMU

SEALANT, TYP.

8" METAL STUD

8" CFMF

5/8" GYP. BD.

6" METAL STUD

5/8" GYP. BD.

8" CFMF

8" CFMF

FLUID APPLIED

AIR BARRIER

SPLIT FACE CMU

CAVITY WALL

INSULATION (R15)

2-1/2" METAL

STUD

5/8" GYP. BD.

2-1/2" CHANNEL

BATT

INSULATION

BATT INSULATION

5/8" GYP. BD.

EXTERIOR

SHEATHING

BATT

INSULATION

CAST STONE

COPING ABOVE

1 3/4"

SPLIT FACE CMU

CAVITY WALL

INSULATION (R-15)

FLUID APPLIED

AIR BARRIER

EXTERIOR

SHEATHING

CAST STONE

COPING ABOVE

8" CMU

8" CFMF

5/8" GYP. BD.

BATT INSULATION

SEALANT, TYP.

8" CFMF

5/8" GYP. BD.

BATT INSULATION

A.3

A.3

1" MIN.

CURTAIN WALL

SYSTEM

CAST STONE

COPING ABOVE

SPLIT FACE CMU

FLUID

APPLIED AIR

BARRIER

BATT INSULATION

BACKER ROD &

SEALANT EA SIDE

EIFS FINISH

3/4"

PLYWOOD

BLKG.

5/8" GYP. BD.

8" CFMF

6" CFMF

5/8" GYP. BD.

1 HR RATED

12" CMU

5/8" GYP. BD.

SEALANT, TYP.

RIGID INSUL.

3/

4"

7 3/4" 1'-0 1/2"

B.9CAST STONE

COPING ABOVE

SPLIT FACE CMU

CAVITY WALL

INSULATION (R-15)

FLUID APPLIED AIR

BARRIER

EXTERIOR

SHEATHING

8" CMU DOOR AND FRAME

AS SCHED.

12" CMU

METAL PANEL

CLOSURE TRIM

PIECE

4 3/4"

1 3/4"

8" CFMF

BATT

INSULATION

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:25 :10 PM

PLAN DETAILS

A-506

JBC/TDB

JEP

GAZ

SCALE: 1 1/2" = 1'-0"

PLAN DETAILA1

SCALE: 1 1/2" = 1'-0"

PLAN DETAILB1

SCALE: 1 1/2" = 1'-0"

PLAN DETAILA2

SCALE: 1 1/2" = 1'-0"

PLAN DETAILC1

6" 1'-6"1'0

1 1/2" = 1'-0"

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:25 :00 PM

ISOMETRIC EXPANION JOINT

A-510

JBC

GAZ

MP

SCALE:

NW VIEW1

SCALE:

SW VIEW2

GENERAL NOTES

A. FIRE PROTECTION, PLUMBING, MECHANICAL, AND

PLUBMING ARE NOT SHOWN FOR CLARITY.

B. EJ-1: ROOF TO WALL CONDITION

C. EJ-2: WALL TO WALL CONDITION

EJ-2

EJ-2

EJ-2

EJ-2

EJ-2

EJ-1

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:25 :06 PM

ISOMETRIC EXPANION JOINT

A-511

JBC

GAZ

MP

SCALE:

SE VIEW1

SCALE:

NE VIEW2

GENERAL NOTES

A. FIRE PROTECTION, PLUMBING, MECHANICAL, AND

PLUBMING ARE NOT SHOWN FOR CLARITY.

B. EJ-1: ROOF TO WALL CONDITION

C. EJ-2: WALL TO WALL CONDITION

EJ-2

EJ-2

EJ-1

EJ-2

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

S2 STEEL

D O

O R

H

EI

G H

T 2"

2" 2"DOOR WIDTH

S4 STEEL

D O

O R

H

EI

G H

T 4"

2" 2"DOOR WIDTH 2" 2"DOOR WIDTH

D2 STEEL

D O

O R

H

EI

G H

T 2"

2" 2"DOOR WIDTH

D4 STEEL

D O

O R

H

EI

G H

T 4"

D O

O R

H

EI

G H

T

DOOR WIDTH

SFX STEEL, EXT

SFI STEEL, INT

SFB STEEL, 45-MIN FR

WFI WOOD, INT

D O

O R

H

EI

G H

T

DOOR WIDTH

WNLI WOOD, INT

GLAZING

REF SPECS

FOR TYPE

D O

O R

H

EI

G H

T

DOOR WIDTH

AFGX ALUM, EXT

GLAZING

REF SPECS

FOR TYPE

2'

D O

O R

H

EI

G H

T

DOOR WIDTH

CCDI COILING COUNTER DOOR, INT

D O

O R

H

EI

G H

T

DOOR WIDTH

SGX STEEL, EXT

GLAZING

REF SPECS

FOR TYPE

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:20 :00 PM

DOOR SCHEDULE

A-600

JMI

JRT/JBC

JBC

DOOR SCHEDULE

MARK

DOOR

FIRE

RATING STC

FRAME

HARDWARE NOTES

SIZE DOOR

TYPE TYPE

DETAIL

WD HGT THK HEAD JAMB SILL

101A 3'-0" 7'-0" 1 3/4" SFB 45 MIN S4 D2/AE-500 C2/AE-500 C711R

101C 3'-0" 7'-0" 1 3/4" SGX S4 D3/AE-500 C3/AE-500 C715

101D 3'-0" 7'-0" 1 3/4" SGX S4 D3/AE-500 C3/AE-500 D725

101E 3'-0" 7'-0" 1 3/4" SGX S4 D3/AE-500 C3/AE-500 D725

102A 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 800AV

103 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101

104 3'-0" 7'-0" 1 3/4" WNLI S2 D2/AE-500 C2/AE-500 101

105A 3'-0" 7'-0" 1 3/4" AFGX S2 715A

105B 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 CX731

105C 3'-0" 7'-0" 1 3/4" SFB 45 MIN D2/AE-500 C2/AE-500 C711R

107 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101

108 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101

109 3'-0" 7'-0" 1 3/4" WFI S2 D1/AE-500 C1/AE-500 801

110 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101

111 3'-0" 7'-0" 1 3/4" WFI S2 D1/AE-500 C1/AE-500 801

112 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101

113 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 801

114A 6'-0" 7'-0" (2)AFGX D2 714A

114B 6'-0" 7'-0" (2)AFGX D2 A1/AE-501 A1/AE-501 800AV

115 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101

116 3'-0" 7'-0" 1 3/4" WNLI S2 D1/AE-500 C1/AE-500 101

117A 3'-0" 7'-0" 1 3/4" WFI S4 D1/AE-500 C1/AE-500 341R

117B 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 203

118 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN D4 D2/AE-500 C2/AE-500 D210R

119A 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN D4 C710R

120A 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 801

120B 3'-0" 7'-0" 1 3/4" WNLI S2 801

121 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 201

122 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 201

123 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 201

124 6'-0" 7'-0" 1 3/4" (2)SFX D4 D4/AE-500 C4/AE-500 214

125 6'-0" 7'-0" 1 3/4" (2)SFX D4 D4/AE-500 C4/AE-500 214

126A 6'-0" 7'-0" 1 3/4" (2)SFI D2 D1/AE-500 C1/AE-500 210

126B 6'-0" 7'-0" 1 3/4" (2)SFX D4 D4/AE-500 C4/AE-500 214

126C 4'-0" 4'-0" 3/4" CCDI - - - 001

127A 6'-0" 7'-0" (2)AFGX D2 B2/AE-505 B3/AE-502 714A

127B 6'-0" 7'-0" (2)AFGX D2 A1/AE-501 A1/AE-501 800AV

128A 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN D4 C710R

128B 6'-0" 7'-0" 1 3/4" (2)SGX D4 D3/AE-500 C3/AE-500 D724

131 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 801

131A 3'-0" 7'-0" 1 3/4" SFI S4 801

132 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 341

133 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 341

134A 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 801

135 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 341

137 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 801

137A 3'-0" 7'-0" 1 3/4" SFI S4 801

138 3'-0" 7'-0" 1 3/4" SFI S2 D1/AE-500 C1/AE-500 341

139A 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 801

140 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 341

141 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 341

142 4'-0" 7'-0" 1 3/4" SFB S4 C201R

143 3'-0" 7'-0" 1 3/4" SFI S4 D1/AE-500 C1/AE-500 203

145 6'-0" 7'-0" 1 3/4" (2)SFX - D4/AE-500 C4/AE-500 714

146 6'-0" 7'-0" 1 3/4" (2)SFX - D4/AE-500 C4/AE-500 714

SCALE: 1/2" = 1'-0"

FRAME TYPES

SCALE: 1/2" = 1'-0"

DOOR TYPES

0 1' 2' 4'

1/2" = 1'-0"

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

9' -0

3' -4

3'

-8

2' -0

TYP NOTE

HEAD

JAMB

SILL

A

D5/AE-502

B1&C1/AE-505

B3/AE-502

7' -0

T

T

TTT

T

T

6'-0" EQEQ

11'-3"

9' -0

2' -0

3'

-8

3' -4

9'-1"

EQ EQ EQ

TYP NOTE

HEAD

JAMB

SILL

B

D5/AE-502

C1&B2/AE-505

B3/AE-502

TTT

GROUND FLOOR

100'-0"

9' -0

EQEQEQ 6'-0" EQ

TYP NOTE

HEAD

JAMB

SILL

C

A4/AE-501

A4/AE-501

B3/AE-502

TT

T T T

TT

7' -0

"TT

2' -0

3'

-8

3' -4

4'-0"

SUNSHADE

PER

ELEVATIONS

4' -0

3'

-4

TYP NOTE

HEAD

JAMB

SILL

D

B4/AE-500

B3/AE-500

B2/AE-500

1/

2"

1/ 2"

1' -4

5'-5"

4' -0

3'

-4

TYP NOTE

HEAD

JAMB

SILL

E

B4/AE-500

B3/AE-500

B2/AE-500

9' -0

3' -4

3'

-8

2' -0

TYP NOTE

HEAD

JAMB

SILL

F

A1/AE-500

A3/AE-505

B3/AE-502

7' -0

T

T

T

T

T

T T

EQ 3'-0" EQ

8'-0"

9' -0

8'-0"

EQ 6'-0" EQ

2' -0

3'

-8

3' -4

TYP NOTE

HEAD

JAMB

SILL

G

A1/AE-500

B2/AE-505

B1/AE-500

T

T

T

T

T

7' -0

"T T

GROUND FLOOR

100'-0"

TYP NOTE

HEAD

JAMB

SILL

H

A1/AE-500

B3/AE-500

B1/AE-500

T TT

T T

8'-0"

EQ 6'-0" EQ

9' -0

2' -0

3'

-8

3' -4

7' -0

"T T

7' -2

3'-8"

TYP NOTE

HEAD

JAMB

SILL

I

B2/AE-501

B3/AE-501

B4/AE-501

T

PRIVACY FILM -

REFER TO SHEET

AE-402 / B1

6 1/4" 2'-11 3/4" 2"

7' -2

6 1/4"

31'-8 3/8"

2" EQ EQ EQ EQ EQ EQ EQ EQ EQ

TYP NOTE

HEAD

JAMB

SILL

J

B2/AE-501

B3/AE-501

B4/AE-501

T T T T T T T T T

PRIVACY FILM - REFER TO

SHEET AE-402 / B1

GROUND FLOOR

100'-0"

4' -0

3'

-4

TYP NOTE

HEAD

JAMB

SILL

K

A4/AE-500

A3/AE-500

A2/AE-500

1, 3

FIRE SHUTTER ON

HANGAR SIDE

GENERAL NOTES

A. ALL FRAME DIMENSIONS ARE NOMINAL ROUGH

OPENING AND CONTRACTOR SHALL COORDINATE

ACTUAL OPENING SIZES WITH RESPECT TO

REQUIRED SHIM SPACE AND ADJACENT MATERIAL.

B. NO EXPOSED FASTENERS SHALL BE ALLOWED IN

ALUMINUM CURTAINWALL FRAMES.

C. PROVIDE MINIMAL EXPANDING FOAM AT PERIMETER

SHIM CAVITY.

D. REFER TO SPECIFICATION SECTION 087100-GLAZING

FOR GLAZING TYPES.

E. TEMPERED GLAZING IS INDICATED WITH A "T".

F. EXTERIOR GLAZING SHALL BE INSULATED.

G. INTERIOR GLAZING SHALL BE NON-INSULATED.

SHEET KEYNOTES

1. CURTAINWALL SYSTEM: 2" X 4 - 1/2" SCREW SPLINE

OR SHEAR BLOCK UNLESS NOTED OTHERWISE.

2. BUTT GLAZED VERTICAL JOINT WITH 2" - 4 - 1/2"

EXTERIOR FRAMING SYSTEM UNLESS NOTED

OTHERWISE.

3. GLAZING IN HANGAR SHALL BE INSULATED.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:24 :39 PM

WINDOW ELEVATIONS

A-601

JMI

GAZ

MP

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

FINISH I.D

FINISH LEGEND

DESCRIPTION PRODUCT LINE OR COLOR SIZE

FLOORING FINISHES

CPT-1 CARPET TILE 3HDP NORDIC STONES-HIDDEN PLAINS / 13-119 ESKER 50CMx50CMx0.31"

PCT-1 PORCELAIN CERAMIC TILE ALASKA ASK04 GLACIER 24"x48"x10.5mm

BASE FINISHES

RB-1 RUBBER BASE TRADITIONAL THERMOSET RUBBER TA6

BEDROCK

WALL FINISHES

PT-1 PAINT

PT-2 PAINT

PT-3 PAINT

PCT-2 PORCELAIN CERAMIC TILE

PCT-7a PORCELAIN CERAMIC TILE

PCT-8a PORCELAIN CERAMIC TILE

PCT-2 PORCELAIN CERAMIC TILE ALASKA ASK04 GLACIER 12"x24"x10.5mm PCT-3 PORCELAIN CERAMIC TILE CBX17 I SEE THE MOON 12"x24"x3/8" PCT-4 PORCELAIN CERAMIC TILE CBX17 I SEE THE MOON I SEE THE MOON; MOSAICS 3"x3"x1/4"

WOC WALK-OFF TILE TT-12 FLUFF CORD STRIP TILE BLACK 12"x12"

COMMENTS

QUARTER TURN INSTALLATION

STACKED INSTALLATION

STACKED INSTALLATION

STACKED INSTALLATION

SHOWER FLOORS

QUARTER TURN INSTALLATION

4" H

PTB-1 PORCELAIN TILE BASE ALASKA ASK04 GLACIER BULLNOSE 4"x24"

WITH TOE FOR RESILIENT;

TOELESS FOR CARPETING

PCT-5 PORCELAIN CERAMIC TILE 12"x24"x3/8"CBX03 SLINKY TILE PATTERN 'A' PCT-6 PORCELAIN CERAMIC TILE 6"x24"x5/16"RETRO ACTIVE ROYAL NAVY PO

6"x24"x10.5mm

6" x 24" x 5/16"

FIELD

12"x24"x10.5mm

CASEWORK FINISHES

PLAM PLASTIC LAMINATE PRALINES AND CREAM WW160 ...

... COUNTERTOPS

SSM-1 SOLID SURFACE MATERIAL CHILLED EARTH 9228SS

ESD ELECTROSTATIC DISSIPATIVE TILE 24"x24"x0.080"ESD RUBBER TILE F410 MARENGO ...

RSF RESILIENT SHEET FLOORING 3mm SHEETSENTICA COLOR: 6525 OCEAN MIST HEAT WELDED SEAMS

SC-1 SEALED CONCRETE

SC-2 SEALED CONCRETE ...CLEAR SEALANT ...

GT-2 GLASS TILE COLOR WAVE STRAIGHT JOINT LINER CW14 TWILIGHT BLUE 1"x6"x5/16" GT-1 GLASS TILE COLOR WAVE RANDOM INTERLOCKIG EVENING MIXER CW28 12"x18"x5/16" ADD 25% MIX OF 1"x6" TWILIGHT BLUE TO

INTERLOCKING MOSAIC EVENING MIXER

ALASKA ASK04 GLACIER

TILE PATTERN 'A'

TILE PATTERN 'B'

TILE PATTERN 'B'

TILE PATTERN 'C'

SHADES AV248 THUNDER UPS 50% MIX

SHADES AV248 THUNDER HON 50% MIX

RETRO ACTIVE ROYAL NAVY PTN

RETRO ACTIVE ROYAL NAVY UPS

RETRO ACTIVE ROYAL NAVY PO

RETRO ACTIVE ROYAL NAVY UPS

4" x 12" x 5/16" 4" x 24" x 5/16" 6" x 12" x 5/16"

... WINDOW SILLSSSM-2 SOLID SURFACE MATERIAL BONE MATTE

PCT-7b

CEILING FINISHES

ACT-1 ACOUSTICAL CEILING TILE CIRRUS HIGH NRC ANGLED TEGULAR NO. 556 WHITE

PT-5 PAINT

24"x24"x7/8"

...0011 SUGAR DUST ...

PRELUDE 15/16" EXPOSED TEE WHITE

MISC. FINISHES

TP TOILET PARTITION HDPE; HAMMERED STAINLESS

WS WINDOW SHADES ...5X MANUAL SHADE SYSTEM; SCREENS 1550 SERIES

3% OPEN. SHADE: 1554 BLACK/BROWN

FASCIA:QUAKER BROWN

GR1 GROUT #540, COLOR: TRUFFLE ... USE WITH PCT1 & PCT2 FLOOR TILES

GR2 GROUT #542, COLOR: GRAYSTONE ... USE WITH TILE PATTERN 'A'

GR3 GROUT #370, COLOR: DOVE GRAY ... USE WITH TILE PATTERN 'B'

SG1 SIGNAGE COPY COLOR: 710 LIGHT GREY

SG2 SIGNAGE HEADER INSERT FINISH: 734 DARK GREY

SG3 SIGNAGE SLIMLINE ENDCAP: 101-ALU ALUMINUM

SG4 SIGNAGE ACCENT INSERT FINISH: 734 DARK GREY

TS TRANSITIONS FINISH: SATIN ANODIZED ALUMINUM ... REFER TO TRANSITION LEGEND IN101 FOR

TRANSITION TYPES

GR4 GROUT #544, COLOR: ROLLING FOG ... USE WITH GLASS TILE

EXMD EXPOSED METAL DECK ...0011 SUGAR DUST ...

EXSF EXPOSED STRUCT. FRAMING ...0011 SUGAR DUST ...

EXDW EXPOSED DUCTWORK &

EQUIPMENT

...0011 SUGAR DUST ...

INSTL INTERIOR STEEL DOORS AND

FRAMES

0508 MIDNIGHT MAGIC

FEC FIRE EXTIGUISHER CABINET STAINLESS STEEL

EXMP EXPOSED METAL PIPING ...0850 CITRON SEMI-GLOSS; ALL METAL PIPES W/OUT

FACTORY APPLIED PAINT OR PROTECTIVE

COATING

LKR LOCKER

EWP ELECTRIC SWITCHES &

RECEPTACLES WALL PLATES

STAINLESS STEEL

ESR ELECTRIC SWITCHES &

RECEPTACLES

GRAY

ACP ACCESS PANELS PAINT TO MATCH ADJACENT SURFACE

EP ELECTRICAL PANEL ANSI 61 GRAY OR STANDARD GRAY FINISH

TWP TELECOMMUNICATION

RECEPTACLE WALL PLATES

STAINLESS STEEL

TA TOILET ACCESSORIES STAINLESS STEEL NO. 4

FRRF FIVE COAT FUEL RESISTIVE

RESINOUS FLOORING

...PRIME: STANDARD PRIMER ...

EPOXY MORTAR: GS; COLOR: SILVER GRAY

GROUT COAT: GS4; COLOR; CLEAR

TOPCOAT: SK6; COLOR: CLEAR FLAT

SEALANT: MP7

0523 FELICITY

0526 METROPOLIS MOOD

0508 MIDNIGHT MAGIC

PCT-8b PCT-8c PCT-8d

ACT-2 ACOUSTICAL CEILING TILE OPTIMA HEALTH ZONE SQUARE TEGULAR NO. 3214PB WHITE 24"x24"x1" CLEAN ROOM 15/16" EXPOSED TEE WHITE

PRF PRIVACY FILM CUSTOM DESIGN TO BE SELECTED BY BASE

SSCG STAINLESS STEEL CORNER

GUARD

STANDARD TYPE 304 STAINLESS STEEL NO. 4 SATIN FINISH 3-1/2" WINGS ...

SSKP STAINLESS STEEL

KICKPLATE

TYPE 304 STAINLESS STEEL NO. 4 SATIN FINISH 12" HIGH ...

FRP-1 FIBERGLASS REINFORCED PANEL 4'x8' ...CLASS A; PEBBLED P100 WHITE

PRIME: STANDARD PRIMER

EPOXY MORTAR: GS; COLOR: SILVER GRAY

GROUT COAT: GS4; COLOR; CLEAR

SEALANT: MP7

FRP-2 FIBERGLASS REINFORCED PANEL 4'x8' ...CLASS A; SMOOTH S 100 S/2/S WHITE

FRP-2 FIBERGLASS REINFORCED PANEL 4'x8' ...CLASS A; SMOOTH S 100 S/2/S WHITE

SG5 SIGNAGE COPY COLOR: 735 RED

VANGUARD; COLOR: 028 GRAY

INTERIOR FINISH

ABBREVIATION LEGEND

ACT ACOUSTICAL CEILING TILE

AFF ABOVE FINISHED FLOOR

CPT CARPET TILE

GYP BD GYPSUM WALL BOARD

ESD ELECTROSTATIC DISSIPATIVE TILE

EXP EXPOSED

FRP FIBERGLASS REINFORCED PLASTIC

FRRF FUEL RESTISTIVE RESINOUS FLOORING

GT GLASS TILE

PCT PORCELAIN CERAMIC TILE

PTB PORCELAIN TILE BASE

PT PAINT

PLAM PLASTIC LAMINATE

RB RESILIENT BASE

RSF RUBBLER SHEET FLOORING

RS ROLLER SHADES

SC SEALED CONCRETE

SSM SOLID SURFACE MATERIAL

TP TOILET PARTITION

WD WOOD

WOC WALK-OFF TILE

WS WINDOW SHADE

GENERAL NOTES

A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD

BE CONSIDERED AS COMPLEMENTARY TO THE

CONSTRUCTION DOCUMENTS AS A WHOLE. ANY

QUESTIONS OR CONFLICTS SHOULD BE BROUGHT

TO THE ARCHITECTS ATTENTION.

B. REFER TO FINISH PLAN SHEETS (IN101 THROUGH

IN102) FOR EXTENTS OF WALL FINISHES.

C. REFER TO FINISH PLAN SHEETS (IN101 THROUGH IN

102) FOR FLOORING INSTALLATION PATTERN.

D. REFER TO INTERIOR FINISH DETAILS SHEET IN-103

FOR WALL TILE PATTERNS.

E. PROVIDE A SMOOTH TRANSITION BETWEEN

DIFFERENT FLOOR MATERIALS.

F. ALL WINDOW SILLS SHALL BE SOLID SURFACE

MATERIAL, SSM-2, UNLESS NOTED OTHERWISE.

G. CENTER FLOORING IN ROOM U.N.O. ON FINISH

PLAN.

H. DO NOT INSTALL TILE LESS THAN 3". CONFIRM

WITH ARCH. PRIOR TO INSTALLATION.

I. REFER TO FINISH MATERIALS SCHEDULE AE-602

FOR MATERIAL MANUFACTURER AND COLOR.

J. REFER TO INTERIOR ELEVATIONS FOR WALL

FINISH/DESIGN INTENT & ENLARGED PLANS.

K. THERE SHALL BE NO EXPOSED TILE EDGES, USE

SCHLUTER TRIM AS INDICATED, TO FINISH ALL

EDGES. SEE DETAILS (SHEET IN-103)

1. PROVIDE TILE PATTERN 'A' ON ALL WALLS.

2. PROVIDE TILE PATTERN 'B' ON ALL WALLS.

3. PROVIDE TILE PATTERN 'C' ON ALL WALLS AS

INDICATED ON INTERIOR ELEVATION SHEETS AE-402

& AE-403 AND FLOOR FINISH PLANS ON SHEETS

IN-101 & IN-102

4. PROVIDE WINDOW SHADES AND SOLID SURFACE

(SSM-2) WINDOW SILLS AT ALL EXTERIOR WINDOWS

THIS ROOM.

5. PAINT FURDOWN ABOVE CABINETS PT-2.

6. REFER TO DETAIL D3/IN-103 FOR WALL TILE TO

FLOOR TRANSITION.

FINISH SCHEDULE NOTES

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021

C :\U sers\gaz\D o cum ents\02700_Arch_G Zalabak Z5W

7D .rvt

4/20/2022 11:22 :25 AM

ROOM FINISH SCHEDULE &

FINISH MATERIALS SCHEDULE

A-602

JMI/TDB

JRT/JBC/TLW

JBC

ROOM FINISH SCHEDULE

ROOM NO. ROOM NAME

FLOOR

FINISH

BASE

FINISH

WALL FINISHES

CEILING FINISH CEILING HEIGHT NOTESNORTH SOUTH EAST WEST

101 WEAPONS TRAINING FRRF - - PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

102 VEST FRRF RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'

103 SHARED OFFICE PCT-1 PTB-1 PT-1 PT-1 PT-2 PT-1 ACT-1 9' 4

104 FUEL OPEN OFFICE PCT-1 PTB-1 PT-1 PT-2 PT-1 PT-1 ACT-1 9' 4

105 VEST WOC-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'

106 CORR PCT-1 PTB-1 PT-1/PT-2/TILE PAT 'C' PT-1 PT-1/PT-2 PT-1 ACT-1 9' 3

107 CLASSROOM CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'

108 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 9' 4

109 RR W PCT-2 - - TILE PAT 'B' TILE PAT 'B' TILE PAT 'B' TILE PAT 'B' GYP BD / PT-5 9' 2

110 WING WEAPONS MGR CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 9' 4

111 RR M PCT-2 - - TILE PAT 'B' TILE PAT 'B' TILE PAT 'B' TILE PAT 'B' GYP BD / PT-5 9' 2

112 FUEL SUPERVISOR CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 9' 4

113 BREAK/ TRAINING PCT-1 PTB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9' 5

114 VEST WOC-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'

115 OFFICE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1 9' 4

116 VINYL OPEN OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 9' 4

117A MOTHER'S ROOM PCT-2 PTB-1 PT-1 PT-1 PT-1 PT-1 GYP BD / PT-5 9'

117B JAN SC-2 RB-1 FRP-1/PT-1 FRP-1/PT-1 FRP-1/PT-1 FRP-1/PT-1 EXP / PT-5 OPEN TO DECK 118 FUEL MAINT. GENERAL STORAGE SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

119 FUEL CELL FRRF - - PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

120A VEST RSF-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'

120B CORR RSF-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'

121 ELEC SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK 1

122 FUEL SC-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-2 9'

123 WASH SC-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-2 9'

124 MECH SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

125 FIRE SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

126 TOOLS SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

127 VEST WOC-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'

128 WASH BAY FRRF - - PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

130 CLEAN M RR PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 131 CLEAN M LR PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 132 CLEAN SHOWER M PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 133 DIRTY SHOWER M PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 134 DIRTY LR M PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' ACT-2 9' 1 135 DIRTY SHOWER M PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 136 CLEAN W RR PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 137 CLEAN W LR PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 138 CLEAN SHOWER W PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 139 DIRTY LR W PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' ACT-2 9' 1 140 DIRTY SHOWER W PCT-3/PCT-4 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 141 DIRTY RR UNISEX PCT-3 - - TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' GYP BD / PT-5 9' 1 142 DIRTY VEST FRRF RB-1 TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' TILE PAT 'A' ACT-1 9' 6 143 MASK WASHING SC-2 RB-1 FRP-1/PT-1 FRP-1/PT-1 FRP-1/PT-1 FRP-1/PT-1 EXP / PT-5 OPEN TO DECK

145 ELEC SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

146 COMM ESD - - PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK

1 ADDENDUM 1 04/22/2022

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

T

T

A

A

C

C

17 17

16 16

ELEC

DIRTY LR M

DIRTY VEST

DIRTY LR W

1'-2"

53'-9 1/8"

22'-0 1/4"

DIRTY

SHOWER W

DIRTY RR

UNISEX

141DIRTY

SHOWER M

DIRTY

SHOWER M

MASK

WASHING

PAINT/SAND/MIX

B1 A-701

C1 A-701

A1 A-701

144B*

144C*

A-701 B4

A-701 B4

A.3

B.9

B.9

'-8

/8

6'-4"

BOLLARD

12'-0" 25'-2"

3" 3"

1' -5

/8

'-6

/8

1'

-2

12' x 6"

TRENCH DRAIN

DIRTY ROOM

144.2

'-8

/8

'-9

/8

20'-10 7/16"

*A6

*Z6

ENVELOPE 6

CLEAN ROOM

144.1

4.

1*

4.

2*

3'-6"

3' -6

25'-0"

3' -6

RATING

10'-0"

144.3*

144A*

A6

A19A6 A6

AIR SHOWER

144.3

F2

*Z6

144.2B*

EXTENTS OF PAINT BOOTH

GROUND FLOOR

100'-0"

AC

A-701 C4

EXTERIOR INSULATION

FINISH SYSTEM

CAST STONE

COPING

SPLIT-FACED

COLORED CMU

T.O. PARAPET

119'-4"

A.3B.9

AWNING

GROUND FLOOR

100'-0"

171819

EXTERIOR INSULATION

FINISH SYSTEM

CAST STONE

COPING

SPLIT-FACED

COLORED CMU

T.O. PARAPET

119'-4"AWNING

MECHANICAL

LOUVER

GROUND FLOOR

100'-0"

HIGH ROOF HANGAR

BAY

134'-4"

EXTERIOR INSULATION

FINISH SYSTEM

CAST STONE

COPING

SPLIT-FACED

COLORED CMU

T.O. PARAPET

119'-4"

A

A

C

C

A-701 C4

A-701 C4

LOW-SLOPE

MEMBRANE ROOF

A.3

B.9

B.9

AWNING

MECHANICAL

EQUIPMENT

PRIMARY

ROOF

DRAIN

OVERFLOW

ROOF

DRAIN

EXTERIOR

LIGHT FIXTURE

GROUND FLOOR

100'-0"

171819

LOAD-BEARING CMU

WALL

HORIZONTAL

INSULATED

METAL PANELS

CAST STONE

COPING

SPLIT-FACE

COLORED CMU

LOW-SLOPE MEMBRANE'

ROOFING

ONE-HOUR FIRE

RATED WALL

A3 A-701

T.O. PARAPET

119'-4"

PAINT/SAND/MIX

DIRTY VEST

'-4

AWNING

SLOPED TOP GYB BD

4"/12" SLOPE

GROUND FLOOR

100'-0"

B2 A-701

A2 A-701

EDGE OF SLAB

CAVITY WALL

INSULATION (R-15)

SPLIT-FACED CMU

CAST STONE

COPING

BATT

INSULATION

(R-25)

5/8" GYPSUM

WALLBOARD

SCHEDULED

CEILING

VAPOR

BARRIER

EXTERIOR

INSULATION

AND FINISH

SYSTEM

(E.I.F.S.)

(R-16)

EXTERIOR

SHEATHING

8" CFMF

8" CFMF

BATT

INSULATION

(R-25)

T.O. PARAPET

119'-4"

MASONRY WALL TIES

BACKER ROD

& SEALANT

STEEL ANGLE

AWNING

EARTH & GRAVEL

EXTERIOR LIGHT

FIXTURE

GROUND FLOOR

100'-0"

EDGE OF SLAB

RIGID CAVITY WALL

INSULATION (R-15)

8" CFMF

5/8" GYP. BD.

PRE-FINISHED

METAL

FLASHING

WEEP

2" THERMAL

SPACE

4" CMU

SPLIT FACE

8" TRACK

8"

MORTAR NET

MASONRY

WALL TIES

SCHEDULED BASE

GROUT FILL

GRAVEL FILL

EARTH

BATT INSULATION (R-25)

EXTERIOR SHEATHING

EXTERIOR INSULATION AND

FINISH SYSTEM (E.I.F.S.) (R-16)

8" CFMF

5/8" GYPSUM WALLBOARD

PRE-FINISHED METAL

PARAPET CAP

ROOF MEMBRANE

WOOD BLOCKING

6" ROOF INSULATION (R-30)

STEEL DECK

VAPOR BARRIER

ROOF MEMBRANE WRAPPED

UP AND OVER TOP OF

PARAPET

ROOF PROTECTION BOARD

T.O. PARAPET

119'-4"

STEEL ANGLE

SLOPE

11 3/4"

GROUND FLOOR

100'-0"

171819

T.O. PARAPET

119'-4"

ENVELOPE 6 ENVELOPE 4

INSPECTION ONLY AREA

LINE OF AIR BARRIER

AIR BARRIER LEGEND

A. THE CONTRACTOR SHALL REFER TO

SPECIFICATIONS SECTION 07 05 23 AND 07 27 10.00

10 FOR ALL AIR BARRIER SYSTEM AND TESTING

REQUIREMENTS.

B. THE CONTRACTOR SHALL REFERENCE WALL

SECTIONS AND DETAILS THAT GRAPHICALLY

INDICATE THE VISUAL PLANE OF THE INTENDED

CONTINUOUS AIR BARRIERS. THE CONTRACTOR

SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL

INTENDED CONTINUOUS AIR BARRIERS ARE IN

PLACE PRIOR TO TESTING.

C. THE CONTRACTOR SHALL JOIN AND SEAL THE AIR

BARRIER MATERIAL OF EACH MATERIAL OF

ADJACENT ASSEMBLIES ALLOWING FOR THE

RELATIVE MOVEMENT OF THESE ASSEMBLIES AND

COMPONENTS.

D. THE CONTRACTOR SHALL MAKE ALL PENETRATIONS

AIRTIGHT AT AIR-BARRIER LOCATIONS INCLUDING

OPENINGS AT OR AROUND ELECTRICAL BOXES,

CONDUIT, PLUMBING, AND OTHER ASSEMBLIES.

E. CONTRACTOR SHALL FILL ALL GAPS AT DISSIMILAR

MATERIALS WITH SPRAY-FOAM INSULATION WHERE

NOT SPECIFICALLY DETAILED.

AIR BARRIER NOTES

AIR BARRIER SUMMARY -

BID OPTION 1

ENVELOPE 4

FLOOR AREA:

WALL AREA:

ROOF AREA:

TOTAL:

ENVELOPE 6

CALCULATIONS LOCATED ON

SHEET A-003

1,674 SF

2,655 SF

1,674 SF

6,003 SF

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021N

N

PROJECT

KEYPLAN

A

PLAN TRUE

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:23 :37 PM

COMPOSITE FLOOR PLAN,

ROOF PLAN, ELEVATIONS,

WALL SECTION & DETAILS - BID

OPTION 1

A-701

JMI

JRT/JBC

JBC

SCALE: 1/8" = 1'-0"

COMPOSITE FLOOR PLAN - BID OPTION 1D1

SCALE: 1/16" = 1'-0"

NORTH ELEVATION - BID OPTION 1C1

SCALE: 1/16" = 1'-0"

WEST ELEVATION - BID OPTION 1B1

SCALE: 1/16" = 1'-0"

EAST ELEVATION - BID OPTION 1A1

SCALE: 1/8" = 1'-0"

COMPOSITE ROOF PLAN - BID OPTION 1D3

SCALE: 1/8" = 1'-0"

BUILDING SECTION - BID OPTION 1C4

SCALE: 3/4" = 1'-0"

WALL SECTION - BID OPTION 1A3SCALE: 1 1/2" = 1'-0"

SECTION DETAILA2

SCALE: 1 1/2" = 1'-0"

SECTION DETAILB2

0 8' 16' 32'

1/16" = 1'-0"

0 4' 8' 16'

1/8" = 1'-0"

1' 3'2'0

3/4" = 1'-0"

6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE: 1/8" = 1'-0"

AIR BARRIER SECTION - BID OPTION 1B4

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

PAINT/SAND/MIX

ELEC

DIRTY VEST

WASH BAY

128142

133 140

139A

137A

134A

131A

144B* 144C*

DIRTY ROOM

144.2

CLEAN ROOM

144.1

144.1*

144.2*

AIR SHOWER

144.3

EXTENTS OF PAINT BOOTH

PAINT/SAND/MIX

1.A.01 TYPE 3

ELEC

DIRTY VEST

WASH BAY

DIRTY ROOM

144.2

1.A.04 TYPE 2

1.A.03 TYPE 2

CLEAN ROOM

144.1

1.A.05 TYPE 6

1.A.06 TYPE 2

1.A.07 TYPE 12

1.A.08 TYPE 2

AIR SHOWER

144.3

EQ10 EQ4

EQ11

EQ12

EXTENTS OF PAINT BOOTH

GENERAL NOTES

A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD

BE CONSIDERED AS COMPLEMENTARY TO THE

CONSTRUCTION DOCUMENTS AS A WHOLE. ANY

QUESTIONS OR CONFLICTS SHOULD BE BROUGHT

TO THE ARCHITECTS ATTENTION.

B. PROVIDE A SMOOTH TRANSITION BETWEEN

DIFFERENT FLOOR MATERIALS.

C. REFER TO A-602 FINISH MATERIALS SCHEDULE FOR

MATERIAL MANUFACTURER AND COLOR.

D. REFER TO COMPOSITE INTERIOR SIGNAGE PLAN

B1/A-702 FOR FURNITURE, FIXTURES AND

EQUIPMENT.

INTERIOR FINISH

ABBREVIATION LEGEND

ACT ACOUSTICAL CEILING TILE

AFF ABOVE FINISHED FLOOR

CPT CARPET TILE

GYP BD GYPSUM WALL BOARD

ESD ELECTROSTATIC DISSIPATIVE TILE

EXP EXPOSED

FRP FIBERGLASS REINFORCED PLASTIC

FRRF FUEL RESTISTIVE RESINOUS FLOORING

GT GLASS TILE

PCT PORCELAIN CERAMIC TILE

PTB PORCELAIN TILE BASE

PT PAINT

PLAM PLASTIC LAMINATE

RB RESILIENT BASE

RSF RUBBLER SHEET FLOORING

RS ROLLER SHADES

SC SEALED CONCRETE

SSM SOLID SURFACE MATERIAL

TP TOILET PARTITION

WD WOOD

WOC WALK-OFF TILE

WS WINDOW SHADE

X.X.XX TYPE X

FLOOR LEVEL

SECTOR (MAY BE A # OR LETTER)

SIGN NUMBER

SIGN TYPE

SIGNAGE LEGEND

D O

O R

H

EI

G H

T

DOOR WIDTH

SFB STEEL, 90-MIN FR

D O

O R

H

EI

G H

T

DOOR WIDTH

OCDX OVERHEAD COILING DOOR, EXT

D

O O

R H

EI

G

H T

DOOR WIDTH

SGX STEEL, EXT

GLAZING

REF DOOR

SCHEDULE

FOR TYPE

S4 STEEL

D O

O R

H

EI

G H

T 4"

2" 2"DOOR WIDTH

D2 STEEL

D O

O R

H

EI

G H

T 2"

2" 2"DOOR WIDTH

SHEET NOTES

1. INTEGRATED 4"H FRRF COVE BASE AT ALL WALLS.

PAINT/SAND/MIX

DIRTY ROOM

144.2

CLEAN ROOM

144.1

110'-6" AIR SHOWER

144.3

111'-6"

2' x 4' FIXTURE - EMERGENCY

EXIT SIGNS

WALL MTD EXTERIOR LIGHT

SUPPLY AIR DIFFUSERS

RETURN AIR GRILLES

1' x 4' FIXTURE - EMERGENCY SUSPENDED

2' x 4' FIXTURE

1' x 4' FIXTURE - SUSPENDED

WALL MTD EXTERIOR LIGHT - EMERGENCY

ACCESS DOORS

TYPICAL CEILING LEGEND

RCP NOTES

A. ALL CEILING SHALL BE 9' - 0" AFF UNLESS NOTED

OTHERWISE.

B. DOWNLIGHTS, WHERE PROVIDED, SHALL BE

CENTERED IN ACOUSTICAL TILE, UNLESS NOTED

OTHERWISE.

C. PROVIDE CONTROL JOINTS IN GYPSUM BOARD

CEILINGS AS REQUIRED IN THE SPECIFICATIONS.

2' x 2' CEILING GRID MOISTURE RESISTANT

GYP BD CEILING

GYP BD CEILING WITH FRP

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021N

N

PROJECT

KEYPLAN

A

PLAN TRUE

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:24 :00 PM

FLOOR FINISH PLAN, ROOM

FINISH SCHEDULE- BID OPTION

A-702

JBC/TDB

JRT/JBC/TLW

JDB/MP

SCALE: 1/8" = 1'-0"

COMPOSITE FLOOR FINISH PLAN - BID OPTION 1C1

ROOM FINISH SCHEDULE - BID OPTION 1

ROOM

NUMBER ROOM NAME

FLOOR

FINISH BASE FINISH

WALL FINISHES

CEILING FINISH CEILING HEIGHT NOTESNORTH SOUTH EAST WEST

144 PAINT/SAND/MIX FRRF FRRF PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK 1

144.1 CLEAN ROOM FRRF FRRF FRP2 FRP2 FRP2 FRP2 GYP BD / FRP2 11'-6" 1

144.2 DIRTY ROOM FRRF FRRF PT-1 PT-1 PT-1 PT-1 EXP / PT-5 OPEN TO DECK 1

144.3 AIR SHOWER FRRF FRRF PT-1 PT-1 PT-1 PT-1 GYP BD / PT-5 10'-6" 1

SCALE: 1/8" = 1'-0"

COMPOSITE INTERIOR SIGNAGE & FURNITURE PLAN - BID OPTION 1B1

INTERIORS SIGNAGE SCHEDULE -BID OPTION 1

SIGN

NUMBER

SIGN

TYPE ROOM NO. ROOM NAME ON DRAWING MESSAGE TEXT (ENGLISH) NOTES

1.A.01 TYPE 3 144 PAINT/SAND/MIX EXIT RE: DETAIL D3/IG-500

1.A.03 TYPE 2 144.1 CLEAN ROOM DIRTY RE: DETAIL D2/IG-500

1.A.04 TYPE 2 144.2 DIRTY ROOM CLEAN RE: DETAIL D2/IG-500

1.A.05 TYPE 6 144 PAINT/SAND/MIX EXTINGUISHER RE: DETAIL C4/IG-500

1.A.06 TYPE 2 144.3 AIR SHOWER PAINT/SAND/MIX RE: DETAIL D2/IG-500

1.A.07 TYPE 12 144.3 AIR SHOWER RE: DETAIL A3/IG-500

1.A.08 TYPE 2 144.3 AIR SHOWER AIR SHOWER RE: DETAIL D2/IG-500

BID OPTION DOOR SCHEDULE

MARK

DOOR

FIRE

RATING STC

FRAME

NOTES

SIZE DOOR

TYPE TYPE

DETAIL

WD HGT THK HEAD JAMB SILL

144.1* 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN

144.2* 6'-0" 7'-0" 1 3/4" (2)SFB 45 MIN

144.2B* 6'-4" 7'-0" 3/4" - - - FABRIC ROLLING DOOR

144.3* 4'-0" 7'-0" 1 3/4" SFB

144A* 4'-0" 7'-0" 1 3/4" SFB

144B* 3'-0" 7'-0" 1 3/4" SGX S4

144C* 12'-0" 12'-0" 3/4" - - -

SCALE: 1/2" = 1'-0"

DOOR TYPES

SCALE: 1/2" = 1'-0"

FRAME TYPES

0 4' 8' 16'

1/8" = 1'-0"

0 1' 2' 4'

1/2" = 1'-0"

TOILET ACCESSORIES - BID OPTION 1

CODE DESCRIPTION LOGISTICS CATEGORY

A6 PAPER TOWEL DISPENSER, TOUCH-FREE

AUTOMATIC

GF/CI

A19 INDUSTRIAL SOAP DISPENSER GF/CI

SCALE: 1/8" = 1'-0"

COMPOSITE REFLECTED CEILING PLAN - BID OPTION 1A1

FURNITURE & EQUIPMENT SCHEDULE - BID OPTION 1

FURNITURE & EQUIPMENT SCHEDULE

CODE DESCRIPTION

EQ4 FULL SIZE REFRIGERATOR W/ ICE & WATER

EQ10 FREEZER

EQ11 DOWNDRAFT MULTI-SLOTTED VENT TABLE

EQ12 DOWNDRAFT SLOTTED VENT TABLE

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

WEAPONS

TRAINING

CLASSROOM

RR W

RR M

SHARED

OFFICE

VEST

FUEL MAINT.

GENERAL

STORAGE

FUEL OPEN

OFFICE

OFFICE

FUEL

SUPERVISOR

WING

WEAPONS

MGR

OFFICE

BREAK/

TRAINING

VINYL OPEN

OFFICE

VEST

MATCHLINE

SEE A1 /

IN-102

MATCHLINE

SEE A1 /

IN-102

TILE PATTERN 'C'

EQ EQ EQ EQ

ALIGN

CORNERS

ALIGN

ALIGN

ALIGN

PT-2

PT

-2

PT-2

PT

-2

PT

-2

PT

-2

PT

-2

PT-2

PT

-2

T O

EN

D

OF

W

AL

L

PT

-2

GENERAL NOTES

A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD

BE CONSIDERED AS COMPLEMENTARY TO THE

CONSTRUCTION DOCUMENTS AS A WHOLE. ANY

QUESTIONS OR CONFLICTS SHOULD BE BROUGHT

TO THE ARCHITECTS ATTENTION.

B. REFER TO FINISH PLAN SHEETS (IN101 THROUGH

IN102) FOR EXTENTS OF WALL FINISHES.

C. REFER TO FINISH PLAN SHEETS (IN101 THROUGH IN

102) FOR FLOORING INSTALLATION PATTERN.

D. REFER TO INTERIOR FINISH DETAILS SHEET IN-103

FOR WALL TILE PATTERNS.

E. PROVIDE A SMOOTH TRANSITION BETWEEN

DIFFERENT FLOOR MATERIALS.

F. ALL WINDOW SILLS SHALL BE SOLID SURFACE

MATERIAL, SSM-2, UNLESS NOTED OTHERWISE.

G. CENTER FLOORING IN ROOM U.N.O. ON FINISH

PLAN.

H. DO NOT INSTALL TILE LESS THAN 3". CONFIRM

WITH ARCH. PRIOR TO INSTALLATION.

I. REFER TO FINISH MATERIALS SCHEDULE AE-602

FOR MATERIAL MANUFACTURER AND COLOR.

J. REFER TO INTERIOR ELEVATIONS FOR WALL

FINISH/DESIGN INTENT & ENLARGED PLANS.

K. THERE SHALL BE NO EXPOSED TILE EDGES, USE

SCHLUTER TRIM AS INDICATED, TO FINISH ALL

EDGES. SEE DETAILS (SHEET IN-103)

FINISH LEGEND

CPT-1: CARPET TILE

PCT-2: PORCELAIN TILE

SC1: SEALED CONCRETE

WOC1: WALK OFF TILE

PCT-3: PORCELAIN TILE

FFRF: FIVE COAT FUEL RESISTIVE

RESINOUS FLOORING

ESD: ELECTROSTATIC

DISSIPATIVE TILE

SC2: SEALED CONCRETE

CPT-2: CARPET TILE

PCT-1: PORCELAIN TILE

RSF: RESILIENT SHEET

FLOORING

PCT-4: PORCELAIN TILE

TS1 - CPT TO PCT, WOC TO PCT

SCHIENE, SATIN ANODIZED ALUMINUM

PROVIDE LEVELER TO BRING BOTH FINISHES TO THE

SAME LEVEL.

TS2 - PCT TO FRRF, PCT TO RSF

RENO-RAMP, SATIN ANODIZED ALUMINUM

TS3 - RSF TO FRRF, RSF TO SC

VINPRO-U, SATIN ANODIZED ALUMINUM

TS4 - RSF TO WOC

VINPRO-S, SATIN ANODIZED ALUMINUM

TS5 - FRRF TO WOC

RENO-RAMP, SATIN ANODIZED ALUMINUM

TS6 - PCT FLOOR TO PCT WALL

DILEX-AHK,SATIN ANODIZED ALUMINUM

TRANSITION LEGEND

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

FSB2020-270-00

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

NWC / JBC

F-

3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin

Ai r N at io na l G ua rd

C

B

A

D

C

B

A

54321

DECEMBER 23, 2021N

N

PLAN TRUE

C :\U sers\nw c\D ocum ents\M y R evit\02700_Arch_ N

C hapm an9285M .rvt

12/22/2021 4:22 :44 PM

PARTIAL FLOOR FINISH PLAN -

SECTOR ONE

IN-101

JBC/TDB

TLW

JBC/MP

SCALE: 1/8" = 1'-0"

PARTIAL FLOOR FINISH PLAN - SECTOR ONEA1

0 4' 8' 16'

1/8" = 1'-0"

PROJECT

KEYPLAN

W

IS C O NS IN

A R C H I T E C T

JASON T.

HOLUBY

A-13101

FIRE

MECH

JAN

117B

FUEL

ELEC

WASH

TOOLS

WASH BAY

ELEC

COMM

CLEAN M RR

DIRTY LR M

DIRTY VEST

DIRTY LR W

CLEAN W RR

CORR

120B

VEST

FUEL CELL

VEST

120A

MOTHER'S

ROOM

117A

MATCHLINE

SEE A1 /

IN-101

MATCHLINE

SEE A1 /

IN-101

B4

IN-102

TILE PATTERN 'C'

CLEAN W LR

CLEAN M LR

MASK

WASHING

DIRTY LR M

DIRTY VEST

DIRTY

SHOWER M

DIRTY

SHOWER M

CLEAN

SHOWER M

CLEAN

SHOWER W

DIRTY

SHOWER W

DIRTY RR

UNISEX

DIRTY LR W

CLEAN W RR

CLEAN M RR

CLEAN W LR

137CLEAN M LR

CORR

120B

TILE PATTERN 'C'

MASK

WASHING

GENERAL NOTES

A. SCHEDULES ARE NOT CONCLUSIVE AND SHOULD

BE CONSIDERED…