Albion Armory Specification 9 of 15.pdf

PDF 3 MB Posted

Attached to
511/21187. CAK; Albion Armory - Renovate Armory
Solicitation number
RFQ - 171 - 220000000461
Issued by
Calhoun County, Alden CDP, Michigan

About this file

This document is a specification for the renovation of the Albion Armory in Albion, Michigan, which is located in Calhoun County. The scope of work includes the installation of new door hardware, glazing, gypsum board, ceramic tile, resilient flooring, acoustical tile ceilings, and exterior painting. Key details include the specific products and materials to be used, installation methods and procedures, and performance requirements. No bid dates, award information, or contract term details are provided.

The specification outlines the requirements for various building materials and finishes, such as safety glass, insulated glass units, gypsum board, ceramic tile, and resilient flooring. It also specifies the standards and testing requirements that must be met. Pricing terms, funding sources, and incumbent contractor information are not included in the document.

View the file

Other files

File Type Posted
Addendum 2 270500 DATA COMMUNICATION SYSTEM 220428.docx DOCX document
Addendum 5 21187.pdf PDF
MtgAttend1 - 21187.pdf PDF
Advertisement 21187.pdf PDF
Addendum No.2 08122022 - 21187.pdf PDF
21-046 Albion Armory - A0.0 - Cover Sheet.pdf PDF
21-046 Albion Armory Civil Drawings.pdf PDF
MtgAttend1 - 21187_REVISED.pdf PDF
Addendum 3 06 Wood Plastics and Composites 21187.pdf PDF
Addendum No.6 08222022 - 21187.pdf PDF
Addendum 1 - 21187.pdf PDF
Albion Armory MEP Set.pdf PDF
Albion Armory Specification 14 of 15.pdf PDF
Albion Armory Specification 12 of 15.pdf PDF
Addendum 3 07 Thermal and Moisture Protection 21187.pdf PDF
Albion Armory Specification 11 of 15.pdf PDF
Albion Armory Specification 3 of 15.pdf PDF
Addendum 2 M-303 - MECHANICAL CONTROLS DIAGRAMS.pdf PDF
Albion Armory Specification 1 of 15.pdf PDF
Albion Armory Specification 7 of 15.pdf PDF
Addendum 3 21187.pdf PDF
Addendum 3 05 Metals 21187.pdf PDF
Albion Armory Draft Logs 11-23-21.pdf PDF
Albion Armory Specification 8 of 15.pdf PDF
Addendum 2 M-301 - MECHANICAL SCHEDULES_ —
Albion Armory Specification 4 of 15.pdf PDF
Addendum 3 08 Openings 21187.pdf PDF
Albion Armory Specification 6 of 15.pdf PDF
Specifications 21187.pdf PDF
Addendum 4 21187.pdf PDF
21-046 Albion Armory Architectural A4-S1 Set.pdf PDF
Albion Armory Draft Map 11-23-21.pdf PDF
Albion Armory Specification 13 of 15.pdf PDF
Albion Armory Specification 15 of 15.pdf PDF
Albion Armory Specification 10 of 15.pdf PDF
Albion Armory Specification 2 of 15.pdf PDF
Albion Armory Specification 5 of 15.pdf PDF
21-046 Albion Armory Architectural A0-A3 Set.pdf PDF
Addendum 2 E-301 - ELECTRICAL DATA.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RENOVATE ARMORY - ALBION ARMORY

1 EA DOOR SWEEP 39A A ZER

1 EA THRESHOLD 65A-V3-223 A ZER

Hardware Group No. 05 101 102

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

1 EA CONT. HINGE 112XY 628 IVE

1 EA PANIC HARDWARE 98-EO 626 VON

1 EA 45 DEGREE OFFSET PULL 8145EZHD 12" O 630-316 IVE

1 EA OH STOP 100S 630 GLY

1 EA SURFACE CLOSER 4111 EDA MC 689 LCN

1 SET WEATHER SEAL (BY FRAME MFR)

1 EA DOOR SWEEP 39A A ZER

1 EA THRESHOLD 65A-V3-223 A ZER

Hardware Group No. 06 103 104 105

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

1 EA CONT. HINGE 112XY 628 IVE

1 EA DUMMY PUSH BAR 350 626 VON

1 EA 45 DEGREE OFFSET PULL 8145EZHD 12" O 630-316 IVE

1 EA OH STOP 100S 630 GLY

1 EA SURFACE CLOSER 4111 EDA MC 689 LCN

Hardware Group No. 07

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE

1 EA OFFICE/ENTRY LOCK L9050L 06N 09-544 L283-711 626 SCH

1 EA SFIC MORTISE CYL. 80-102 626 SCH

1 EA OH STOP 90S 652 GLY

1 EA SURFACE CLOSER 4011 MC 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE

1 EA GASKETING 488SBK PSA BK ZER

Hardware Group No. 08 107 115

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE

1 EA PASSAGE SET L9010 06N 626 SCH

DOOR HARDWARE 087100 - 13

1 EA SURFACE CLOSER 4011 MC 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE

1 EA WALL STOP WS33X 626 IVE

1 EA GASKETING 488SBK PSA BK ZER

Hardware Group No. 09

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA OFFICE/ENTRY LOCK L9050L 06N 09-544 L283-711 626 SCH

1 EA SFIC MORTISE CYL. 80-102 626 SCH

1 EA WALL STOP WS33X 626 IVE

1 EA GASKETING 488SBK PSA BK ZER

Hardware Group No. 10 111 113

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE

1 EA PUSH PLATE 8200 6" X 16" 630 IVE

1 EA PULL PLATE 8302 8" 4" X 16" 630 IVE

1 EA SURFACE CLOSER 4011 MC 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE

1 EA WALL STOP WS33X 626 IVE

1 EA GASKETING 488SBK PSA BK ZER

Hardware Group No. 11 112 114

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA PUSH PLATE 8200 6" X 16" 630 IVE

1 EA PULL PLATE 8302 8" 4" X 16" 630 IVE

1 EA SURFACE CLOSER 4011 MCSRI 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE

1 EA WALL STOP WS33X 626 IVE

1 EA GASKETING 488SBK PSA BK ZER

Hardware Group No. 12

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

DOOR HARDWARE 087100 - 14

1 EA PRIVACY W/COIN TURN L9044 06N 09-544 L283-722 626 SCH

1 EA SURFACE CLOSER 4011 MC 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE

1 EA WALL STOP WS33 626 IVE

1 EA WALL STOP WS33X 626 IVE

1 EA GASKETING 488SBK PSA BK ZER

Hardware Group No. 13

EACH TO HAVE:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA STOREROOM LOCK L9080L 06N 626 SCH

1 EA SFIC MORTISE CYL. 80-102 626 SCH

1 EA WALL STOP WS33 626 IVE

1 EA GASKETING 488SBK PSA BK ZER

END OF SECTION 08 71 00

DOOR HARDWARE 087100 - 15

SECTION 088000 - GLAZING

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes:

1. Glass for windows and doors.

2. Glazing sealants and accessories.

1.2 SUBMITTALS

A. Product Data: For each type of product.

B. Product Certificates: For glass and glazing products, from manufacturer.

C. Glass Samples: For each type of glass product other than clear monolithic vision glass; 12 inches square.

D. Glazing Schedule: List glass types and thicknesses for each size opening and location. Use same designations indicated on Drawings.

E. Warranties: Sample of special warranties.

1.3 QUALITY ASSURANCE

A. Glazing Publications: Comply with published recommendations of glass product manufacturers and organizations below, unless more stringent requirements are indicated.

1. GANA Publications: GANA's "Glazing Manual."

B. Safety Glazing Labeling: Where safety glazing labeling is indicated, permanently mark glazing with certification label of the SGCC or another certification agency acceptable to authorities having jurisdiction or the manufacturer. Label shall indicate manufacturer's name, type of glass, thickness, and safety glazing standard with which glass complies.

C. Fire-Protection-Rated Glazing Labeling: Permanently mark fire-protection-rated glazing with certification label of a testing agency acceptable to authorities having jurisdiction. Label shall indicate manufacturer's name, test standard, whether glazing is for use in fire doors or other openings, whether or not glazing passes hose-stream test, whether or not glazing has a temperature rise rating of 450 deg F, and the fire-resistance rating in minutes.

D. Insulating-Glass Certification Program: Permanently marked either on spacers or on at least one component lite of units with appropriate certification label of IGCC.

GLAZING 088000 - 1

1.4 WARRANTY

A. Manufacturer's Special Warranty for Coated-Glass Products: Manufacturer agrees to replace coated-glass units that deteriorate within specified warranty period. Deterioration of coated glass is defined as defects developed from normal use that are not attributed to glass breakage or to maintaining and cleaning coated glass contrary to manufacturer's written instructions. Defects include peeling, cracking, and other indications of deterioration in coating.

1. Warranty Period: 10 years from date of Substantial Completion.

B. Manufacturer's Special Warranty for Laminated Glass: Manufacturer agrees to replace laminated-glass units that deteriorate within specified warranty period. Deterioration of laminated glass is defined as defects developed from normal use that are not attributed to glass breakage or to maintaining and cleaning laminated glass contrary to manufacturer's written instructions. Defects include edge separation, delamination materially obstructing vision through glass, and blemishes exceeding those allowed by referenced laminated-glass standard.

1. Warranty Period: 10 years from date of Substantial Completion.

C. Manufacturer's Special Warranty for Insulating Glass: Manufacturer agrees to replace insulating-glass units that deteriorate within specified warranty period. Deterioration of insulating glass is defined as failure of hermetic seal under normal use that is not attributed to glass breakage or to maintaining and cleaning insulating glass contrary to manufacturer's written instructions. Evidence of failure is the obstruction of vision by dust, moisture, or film on interior surfaces of glass.

1. Warranty Period: 10 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 GLASS PRODUCTS, GENERAL

A. Thickness: Where glass thickness is indicated, it is a minimum. Provide glass that complies with performance requirements and is not less than the thickness indicated.

B. Strength: Where annealed float glass is indicated, provide annealed float glass, heat-strengthened float glass, or fully tempered float glass. Where heat-strengthened float glass is indicated, provide heat-strengthened float glass or fully tempered float glass. Where fully tempered float glass is indicated, provide fully tempered float glass.

2.2 GLASS PRODUCTS

A. Safety Glass: Category II materials complying with testing requirements in 16 CFR 1201.

Provide safety glazing labeling where safety glass is indicated.

GLAZING 088000 - 2

B. Clear Annealed Float Glass: ASTM C 1036, Type I, Class 1 (clear), Quality-Q3.

C. Tinted Annealed Float Glass: ASTM C 1036, Type I, Class 2 (tinted), Quality-Q3.

D. Fully Tempered Float Glass: ASTM C 1048, Kind FT (fully tempered), Condition A (uncoated) unless otherwise indicated, Type I, Class 1 (clear) or Class 2 (tinted) as indicated, Quality-Q3.

E. Heat-Strengthened Float Glass: ASTM C 1048, Kind HS (heat strengthened), Type I, Condition A (uncoated) unless otherwise indicated, Type I, Class 1 (clear) or Class 2 (tinted) as indicated, Quality-Q3.

2.3 TYPE 1 GLAZING G1 (Used at exterior doors and windows)

A. Insulated Glass Units: Factory-assembled units consisting of sealed lites separated by a interspace with laminated double pane, insulated, high-performance, security glass including the following:

1. Double pane insulated high-performance glass of 15/16 inch or 1 inch total thickness.

2. Tint low-E coating, and performance shall equal PPG Architectural Glass.

3. Outside Board - 3/16" thick, tempered strength, tinted.

4. Inside Board – A laminated board consisting of 1/8” thick heat strengthened, high performance clear glass, a Clear 0.060” Saflex IIIG (R Series) (PVB) interlayer and 1/8” thick heat strengthened, high performance clear glass, interlayer following paragraph 5 below.

5. Polyvinyl Butyral (PVB), Plastic interlayer shall be equal to Saflex high performance IIIG (PVG) 0.060” thickness, clear. See 8 below.

6. Low-E coating, equal to PPG's commercial applications, Solarban 60 shall be applied to surface #2.

7. Tint equal to PPG’s Solar Bronze, shall be applied to the outside board; having 59% visible light transmittance, a shading coefficient of 0.77, and ultraviolet transmittance of 29% at ¼ inch glass thickness.

8. Basis of Design: Subject to compliance with requirements provide Saflex Laminate interlayer or approved equal.

a. Other Manufacturers of the Laminated Architectural Glass are:

1) Viracon Inc. 800 Park Drive, Owatonna, MN 55060, Phone (507)451-9555.

2) Standard Bent Glass Inc. P.O. Box 469, Butler PA 16003-0469 Phone

(724)287-3747.

GLAZING 088000 - 3

2.4 TYPE 2 GLAZING G2 (Used at interior doors)

A. Monolithic Glass Type: Safety glass, Clear Kind FT, fully tempered float glass.

1. Thickness: ¼ inch.

2.5 TYPE 3 GLAZING G3 (Used at interior vestibule doors)

A. Insulated Glass Units: Factory-assembled units consisting of sealed lites separated by a interspace including the following:

1. Double pane insulated high performance glass of 15/16” total thickness.

2. Outside Board – 3/16” thick, tempered strength, high-performance clear glass.

3. Inside Board - 3/16” thick, tempered strength, high-performance clear glass.

4. Clear glass; equal to PPG’s glass having 89% visible light transmittance, a shading coefficient of 0.96, and ultraviolet transmittance of 68% at 3/16” glass thickness.

2.6 TYPE 4 GLAZING G4 (Used in fire rated assemblies)

A. 90-minute fire-rated glazing; film-faced ceramic glazing.

1. Provide safety glazing labeling.

B. Fire-Protection-Rated Glazing, General: Listed and labeled by a testing agency acceptable to authorities having jurisdiction, for fire-protection ratings indicated, based on testing according to NFPA 252 for door assemblies.

C. Film-Faced Ceramic Glazing: Clear, ceramic flat glass; 5-mm thickness; faced on one surface with a clear glazing film; and complying with 16 CFR 1201, Category II.

1. Products: Subject to compliance with requirements, available products that may be incorporated into the Work include, but are not limited to, the following:

a. Air Louvers, Safti First; Pyran Platinum F.

b. Technical Glass Products; FireLite NT.

2.7 GLAZING SEALANTS

A. General:

1. Compatibility: Compatible with one another and with other materials they contact, including glass products, seals of insulating-glass units, and glazing channel substrates, under conditions of service and application, as demonstrated by sealant manufacturer based on testing and field experience.

2. Suitability: Comply with sealant and glass manufacturers' written instructions for selecting glazing sealants suitable for applications indicated and for conditions existing at time of installation.

3. Colors of Exposed Glazing Sealants: As selected by Design Professional from manufacturer's full range.

B. Glazing Sealants for Insulated Glass Units (G1): THE G1 SEALANT TO BE USED ON THE

INTERIOR FOR THE INSULATED GLASS ON THE CROSS DOOR UNITS AND

WINDOWS SHALL BE DOW CORNING 995 SILICONE STRUCTURAL ADHESIVE

GLAZING 088000 - 4

meeting Fed Spec TT-S-001543A, TT-S-00230C AND ASTM C-920 TYPE S, GRADE NS, CLASS 25. SEE DRAWING FOR DETAIL.

C. Glazing Sealants for Fire-Rated Glazing Products: Products that are approved by testing agencies that listed and labeled fire-resistant glazing products with which they are used for applications and fire-protection ratings indicated.

2.8 MISCELLANEOUS GLAZING MATERIALS

A. Cleaners, Primers, and Sealers: Types recommended by sealant or gasket manufacturer.

B. Setting Blocks: Elastomeric material with a Shore, Type A durometer hardness of 85, plus or minus 5.

C. Spacers: Elastomeric blocks or continuous extrusions of hardness required by glass manufacturer to maintain glass lites in place for installation indicated.

D. Edge Blocks: Elastomeric material of hardness needed to limit glass lateral movement (side walking).

E. Cylindrical Glazing Sealant Backing: ASTM C 1330, Type O (open-cell material), of size and density to control glazing sealant depth and otherwise produce optimum glazing sealant performance.

PART 3 - EXECUTION

3.1 GLAZING, GENERAL

A. Comply with combined written instructions of manufacturers of glass, sealants, gaskets, and other glazing materials, unless more stringent requirements are indicated, including those in referenced glazing publications.

B. Protect glass edges from damage during handling and installation. Remove damaged glass from Project site and legally dispose of off Project site. Damaged glass includes glass with edge damage or other imperfections that, when installed, could weaken glass, impair performance, or impair appearance.

C. Apply primers to joint surfaces where required for adhesion of sealants, as determined by preconstruction testing.

D. Install setting blocks in sill rabbets, sized and located to comply with referenced glazing publications, unless otherwise required by glass manufacturer. Set blocks in thin course of compatible sealant suitable for heel bead.

E. Do not exceed edge pressures stipulated by glass manufacturers for installing glass lites.

GLAZING 088000 - 5

F. Provide spacers for glass lites where length plus width is larger than 50 inches.

G. Provide edge blocking where indicated or needed to prevent glass lites from moving sideways in glazing channel, as recommended in writing by glass manufacturer and according to requirements in referenced glazing publications.

3.2 CLEANING AND PROTECTION

A. Immediately after installation remove nonpermanent labels and clean surfaces.

B. Protect glass from contact with contaminating substances resulting from construction operations. Examine glass surfaces adjacent to or below exterior concrete and other masonry surfaces at frequent intervals during construction, but not less than once a month, for buildup of dirt, scum, alkaline deposits, or stains.

1. If, despite such protection, contaminating substances do come into contact with glass, remove substances immediately as recommended in writing by glass manufacturer.

Remove and replace glass that cannot be cleaned without damage to coatings.

C. Remove and replace glass that is damaged during construction period.

END OF SECTION 088000

GLAZING 088000 - 6

SECTION 092900 - GYPSUM BOARD

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1.Interior gypsum board.

1.2 ACTION SUBMITTALS

A. Product Data: For the following:

1.Gypsum wallboard.

2.Gypsum ceiling board.

3.Abuse-resistant gypsum board.

B. Samples: For the following products:

1.Trim Accessories: Full-size Sample in 12-inch- long length for each trim accessory indicated.

1.3 DELIVERY, STORAGE AND HANDLING

A. Store materials inside under cover and keep them dry and protected against weather, condensation, direct sunlight, construction traffic, and other potential causes of damage.

Stack panels flat and supported on risers on a flat platform to prevent sagging.

1.4 FIELD CONDITIONS

A. Environmental Limitations: Comply with ASTM C840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

B. Do not install paper-faced gypsum panels until installation areas are enclosed and conditioned.

C. Do not install panels that are wet, moisture damaged, and mold damaged.

1.Indications that panels are wet or moisture damaged include, but are not limited to, discoloration, sagging, or irregular shape.

2.Indications that panels are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. STC-Rated Assemblies: For STC-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E90 and classified according to ASTM E413 by an independent testing agency.

B. Ceiling and wall materials shall comply with the requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers."

GYPSUM BOARD 092900 - 1

2.2 INTERIOR GYPSUM BOARD

A. Gypsum Wallboard: ASTM C1396/C1396M.

1.Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. Continental Building Products Inc.

b. Georgia-Pacific Gypsum LLC

c. National Gypsum Company

2.Thickness: 5/8 inch.

3.Long Edges: Tapered.

4.Use ‘Glass Matte’ gypsum board behind ceramic tile in toilet and shower rooms B. Gypsum Ceiling Board: ASTM C1396/C1396M.

1.Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. Continental Building Products Inc.

b. Georgia-Pacific Gypsum LLC

c. National Gypsum Company

2.Thickness: 5/8 inch.

3.Long Edges: Tapered.

C. Abuse-Resistant Gypsum Board: ASTM C1396/C1396M gypsum board, tested according to ASTM C1629/C1629M.

1.Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. Continental Building Products Inc.

b. Georgia-Pacific Gypsum LLC

c. National Gypsum Company

2.Core: As indicated on Drawings.

3.Surface Abrasion: ASTM C1629/C1629M, meets or exceeds Level 2 requirements.

4.Indentation: ASTM C1629/C1629M, meets or exceeds Level 2 requirements.

5.Soft-Body Impact: ASTM C1629/C1629M, meets or exceeds Level 2 requirements.

6.Long Edges: Tapered.

7.Mold Resistance: ASTM D3273, score of 10 as rated according to ASTM D3274.

2.3 JOINT TREATMENT MATERIALS

A. General: Comply with ASTM C475/C475M.

GYPSUM BOARD 092900 - 2

B. Joint Tape:

1.Interior Gypsum Board: Paper.

C. Joint Compound for Interior Gypsum Board: For each coat, use formulation that is compatible with other compounds applied on previous or for successive coats.

1.Prefilling: At open joints and damaged surface areas, use setting-type taping compound.

2.Embedding and First Coat: For embedding tape and first coat on joints, fasteners, and trim flanges, use setting-type taping compound.

a. Use setting-type compound for installing paper-faced metal trim accessories.

3.Fill Coat: For second coat, use setting-type, sandable topping compound.

4.Finish Coat: For third coat, use drying-type, all-purpose compound.

D. Joint Compound for Tile Backing Panels:

1.Water-Resistant Gypsum Backing Board: Use setting-type taping compound and setting-type, sandable topping compound.

2.4 AUXILIARY MATERIALS

A. Provide auxiliary materials that comply with referenced installation standards and manufacturer's written instructions.

B. Laminating Adhesive: Adhesive or joint compound recommended for directly adhering gypsum panels to continuous substrate.

1.from Indoor Sources Using Environmental Adhesive shall comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers."

C. Steel Drill Screws: ASTM C1002 unless otherwise indicated.

1.Use screws complying with ASTM C954 for fastening panels to steel members from 0.033 to

0.112 inch thick.

D. Sound-Attenuation Blankets: ASTM C665, Type I (blankets without membrane facing) produced by combining thermosetting resins with mineral fibers manufactured from glass, slag wool, or rock wool.

E. Acoustical Sealant: As specified in Section 079219 "Acoustical Joint Sealants."

GYPSUM BOARD 092900 - 3

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine areas and substrates including welded hollow-metal frames and support framing, with Installer present, for compliance with requirements and other conditions affecting performance of the Work.

B. Examine panels before installation. Reject panels that are wet, moisture damaged, and mold damaged.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION AND FINISHING OF PANELS, GENERAL

A. Comply with ASTM C840.

B. Install ceiling panels across framing to minimize the number of abutting end joints and to avoid abutting end joints in central area of each ceiling. Stagger abutting end joints of adjacent panels not less than one framing member.

C. Install panels with face side out. Butt panels together for a light contact at edges and ends with not more than 1/16 inch of open space between panels. Do not force into place.

D. Locate edge and end joints over supports, except in ceiling applications where intermediate supports or gypsum board back-blocking is provided behind end joints. Do not place tapered edges against cut edges or ends. Stagger vertical joints on opposite sides of partitions. Do not make joints other than control joints at corners of framed openings.

E. Form control and expansion joints with space between edges of adjoining gypsum panels.

F. Isolate perimeter of gypsum board applied to non-load-bearing partitions at structural abutments. Provide 1/4- to 1/2-inch- wide spaces at these locations and trim edges with edge trim where edges of panels are exposed.

Seal joints between edges and abutting structural surfaces with acoustical sealant.

G. Attachment to Steel Framing: Attach panels so leading edge or end of each panel is attached to open (unsupported) edges of stud flanges first.

H. STC-Rated Assemblies: Seal construction at perimeters, behind control joints, and at openings and penetrations with a continuous bead of acoustical sealant. Install acoustical sealant at both faces of partitions at perimeters and through penetrations. Comply with ASTM C919 and with manufacturer's written instructions for locating edge trim and closing off sound-flanking paths around or through assemblies, including sealing partitions above acoustical ceilings.

GYPSUM BOARD 092900 - 4

I. Install sound attenuation blankets before installing gypsum panels unless blankets are readily installed after panels have been installed on one side.

3.3 INSTALLATION OF INTERIOR GYPSUM BOARD

A. Install interior gypsum board in the following locations:

1.Wallboard Type: Vertical surfaces unless otherwise indicated.

2.Ceiling Type: Ceiling surfaces.

3.Impact-Resistant Type: As indicated on Drawings.

B. Single-Layer Application:

1.On ceilings, apply gypsum panels before wall/partition board application to greatest extent possible and at right angles to framing unless otherwise indicated.

2.On partitions/walls, apply gypsum panels horizontally (perpendicular to framing) unless otherwise indicated or required by fire-resistance-rated assembly, and minimize end joints.

a. Stagger abutting end joints not less than one framing member in alternate courses of panels.

3.On Z-shaped furring members, apply gypsum panels vertically (parallel to framing) with no end joints. Locate edge joints over furring members.

4.Fastening Methods: Apply gypsum panels to supports with steel drill screws.

3.4 FINISHING OF GYPSUM BOARD

A. General: Treat gypsum board joints, interior angles, edge trim, control joints, penetrations, fastener heads, surface defects, and elsewhere as required to prepare gypsum board surfaces for decoration. Promptly remove residual joint compound from adjacent surfaces.

B. Prefill open joints and damaged surface areas.

C. Apply joint tape over gypsum board joints, except for trim products specifically indicated as not intended to receive tape.

D. Gypsum Board Finish Levels: Finish panels to levels indicated below and according to ASTM C840:

1.Level 1: Ceiling plenum areas, concealed areas, and where indicated.

2.Level 2: Panels that are substrate for tile 3.Level 4: At panel surfaces that will be exposed to view unless otherwise indicated.

GYPSUM BOARD 092900 - 5

a. Primer and its application to surfaces are specified in Section 099123 "Interior Painting."

3.5 PROTECTION

A. Protect adjacent surfaces from drywall compound and promptly remove from floors and other non-drywall surfaces. Repair surfaces stained, marred, or otherwise damaged during drywall application.

B. Protect installed products from damage from weather, condensation, direct sunlight, construction, and other causes during remainder of the construction period.

C. Remove and replace panels that are wet, moisture damaged, and mold damaged.

1.Indications that panels are wet or moisture damaged include, but are not limited to, discoloration, sagging, or irregular shape.

2.Indications that panels are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration.

END OF SECTION 092900

GYPSUM BOARD 092900 - 6

SECTION 093013 - CERAMIC TILING

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1.Ceramic mosaic tile.

2.Porcelain tile.

3.Glazed wall tile.

4.Thresholds.

1.2 DEFINITIONS

A. General: Definitions in the ANSI A108 series of tile installation standards and in ANSI A137.1 apply to Work of this Section unless otherwise specified.

B. Face Size: Actual tile size, excluding spacer lugs.

C. Module Size: Actual tile size plus joint width indicated.

1.3 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. Sustainable Design Submittals:

1.Product Data: For adhesives, indicating VOC content.

2.Laboratory Test Reports: For adhesives, indicating compliance with requirements for low-emitting materials.

3.Laboratory Test Reports: For sealers, indicating compliance with requirements for low-emitting materials.

C. Samples for Initial Selection: For tile, grout, and accessories involving color selection.

D. Samples for Verification:

1.Full-size units of each type and composition of tile and for each color and finish required.

2.Full-size units of each type of trim and accessory.

3.Metal edge strips in 6-inch lengths.

1.4 INFORMATIONAL SUBMITTALS

A. Qualification Data: For Installer.

B. Product Certificates: For each type of product.

C. Product Test Reports: For tile-setting and -grouting products.

1.5 MAINTENANCE MATERIAL SUBMITTALS

A. Furnish extra materials that match and are from same production runs as products installed and that are packaged with protective covering for storage and identified with labels describing contents.

1.Tile and Trim Units:

a. 5% of the total tile or trim area.

CERAMIC TILING 093013 - 1

2.Grout: Furnish quantity of grout equal to 3 percent of amount installed for each type, composition, and color indicated.

1.6 QUALITY ASSURANCE

A. Installer Qualifications:

1.Installer is a Trowel of Excellence member of the Tile Contractors' Association of America.

2.Installer employs only installers recognized by the U.S. Department of Labor as Journeyman Tile Layers for Project.

1.7 DELIVERY, STORAGE, AND HANDLING

A. Deliver and store packaged materials in original containers with seals unbroken and labels intact until time of use.

Comply with requirements in ANSI A137.1 for labeling tile packages.

B. Store tile and cementitious materials on elevated platforms, under cover, and in a dry location.

C. Store aggregates where grading and other required characteristics can be maintained and contamination can be avoided.

D. Store liquid materials in unopened containers and protected from freezing.

1.8 FIELD CONDITIONS

A. Environmental Limitations: Do not install tile until construction in spaces is complete and ambient temperature and humidity conditions are maintained at the levels indicated in referenced standards and manufacturer's written instructions.

PART 2 - PRODUCTS

2.1 MANUFACTURES

A. Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

Daltile Ceramic and Porcelain Atlas Concorde Marazzi USA

2.2 SOURCE LIMITATIONS

A. Source Limitations for Tile: Obtain tile of each type and color or finish from single source or producer.

1.Obtain tile of each type and color or finish from same production run and of consistent quality in appearance and physical properties for each contiguous area.

B. Source Limitations for Setting and Grouting Materials:

Obtain ingredients of a uniform quality for each mortar, CERAMIC TILING 093013 - 2 adhesive, and grout component from single manufacturer and each aggregate from single source or producer.

1.Obtain setting and grouting materials, except for unmodified Portland cement and aggregate, from single manufacturer.

2.3 PRODUCTS, GENERAL

A. ANSI Ceramic Tile Standard: Provide tile that complies with ANSI A137.1 for types, compositions, and other characteristics indicated.

1.Provide tile complying with Standard grade requirements.

B. ANSI Standards for Tile Installation Materials: Provide materials complying with ANSI A108.02, ANSI standards referenced in other Part 2 articles, ANSI standards referenced by TCNA installation methods specified in tile installation schedules, and other requirements specified.

C. Factory Blending: For tile exhibiting color variations within ranges, blend tile in factory and package so tile units taken from one package show same range in colors as those taken from other packages and match approved Samples.

D. Mounting: For factory-mounted tile, provide back- or edge-mounted tile assemblies as standard with manufacturer unless otherwise indicated.

1.Where tile is indicated for installation in wet areas, do not use back- or edge-mounted tile assemblies unless tile manufacturer specifies in writing that this type of mounting is suitable for installation indicated and has a record of successful in-service performance.

2.4 THRESHOLDS

A. General: Fabricate to sizes and profiles indicated or required to provide transition between adjacent floor finishes.

1.Bevel edges at 1:2 slope, with lower edge of bevel aligned with or up to 1/16 inch above adjacent floor surface. Finish bevel to match top surface of threshold. Limit height of threshold to 1/2 inch or less above adjacent floor surface.

B. Marble Thresholds: ASTM C503/C503M, with a minimum abrasion resistance of 12 according to ASTM C1353 or ASTM C241/C241M and with honed finish.

1.Description:

a. Uniform, fine- to medium-grained white stone with gray veining.

b. Provide the following:

CERAMIC TILING 093013 - 3

1) .

C. Mix mortars and grouts to comply with referenced standards and mortar and grout manufacturers' written instructions.

D. Add materials, water, and additives in accurate proportions.

E. Obtain and use type of mixing equipment, mixer speeds, mixing containers, mixing time, and other procedures to produce mortars and grouts of uniform quality with optimum performance characteristics for installations indicated.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions where tile will be installed, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.

1.Verify that substrates for setting tile are firm; dry;

clean; free of coatings that are incompatible with tile-setting materials, including curing compounds and other substances that contain soap, wax, oil, or silicone; and comply with flatness tolerances required by ANSI A108.01 for installations indicated.

2.Verify that concrete substrates for tile floors installed with bonded mortar bed or thinset mortar comply with surface finish requirements in ANSI A108.01 for installations indicated.

a. Verify that surfaces that received a steel trowel finish have been mechanically scarified.

b. Verify that protrusions, bumps, and ridges have been removed by sanding or grinding.

3.Verify that installation of grounds, anchors, recessed frames, electrical and mechanical units of work, and similar items located in or behind tile has been completed.

4.Verify that joints and cracks in tile substrates are coordinated with tile joint locations; if not coordinated, adjust joint locations in consultation with Architect.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 PREPARATION

A. Fill cracks, holes, and depressions in concrete substrates for tile floors installed with thinset mortar with trowelable

CERAMIC TILING 093013 - 4

leveling and patching compound specifically recommended by tile-setting material manufacturer.

B. Where indicated, prepare substrates to receive waterproof membrane by applying a reinforced mortar bed that complies with ANSI A108.1A and is sloped 1/4 inch per foot toward drains.

C. Blending: For tile exhibiting color variations, verify that tile has been factory blended and packaged so tile units taken from one package show same range of colors as those taken from other packages and match approved Samples. If not factory blended, either return to manufacturer or blend tiles at Project site before installing.

3.3 INSTALLATION OF CERAMIC TILE

A. Comply with TCNA's "Handbook for Ceramic, Glass, and

Stone Tile Installation" for TCNA installation methods specified in tile installation schedules. Comply with parts of the ANSI A108 series "Specifications for Installation of Ceramic Tile" that are referenced in TCNA installation methods, specified in tile installation schedules, and apply to types of setting and grouting materials used.

1.For the following installations, follow procedures in the ANSI A108 series of tile installation standards for providing 95 percent mortar coverage:

a. Tile floors in wet areas.

B. Extend tile work into recesses and under or behind equipment and fixtures to form complete covering without interruptions unless otherwise indicated. Terminate work neatly at obstructions, edges, and corners without disrupting pattern or joint alignments.

C. Accurately form intersections and returns. Perform cutting and drilling of tile without marring visible surfaces.

Carefully grind cut edges of tile abutting trim, finish, or built-in items for straight aligned joints. Fit tile closely to electrical outlets, piping, fixtures, and other penetrations so plates, collars, or covers overlap tile.

D. Provide manufacturer's standard trim shapes where necessary to eliminate exposed tile edges.

E. Where accent tile differs in thickness from field tile, vary setting-bed thickness so that tiles are flush.

F. Jointing Pattern: Lay tile in grid pattern unless otherwise indicated. Lay out tile work and center tile fields in both directions in each space or on each wall area. Lay out tile work to minimize the use of pieces that are less than half of a tile. Provide uniform joint widths unless otherwise indicated.

CERAMIC TILING 093013 - 5

1.Where adjoining tiles on floor, base, walls, or trim are specified or indicated to be same size, align joints.

2.Where tiles are specified or indicated to be whole integer multiples of adjoining tiles on floor, base, walls, or trim, align joints unless otherwise indicated.

G. Joint Widths: Unless otherwise indicated, install tile with the following joint widths:

1.Ceramic Mosaic Tile: 1/16 inch.

2.Glazed Wall Tile: 1/16 inch.

3.Porcelain Tile: 1/4 inch.

H. Lay out tile wainscots to dimensions indicated or to next full tile beyond dimensions indicated.

I. Stone Thresholds: Install stone thresholds in same type of setting bed as adjacent floor unless otherwise indicated.

1.At locations where mortar bed (thickset) would otherwise be exposed above adjacent floor finishes, set thresholds in modified dry-set mortar (thinset).

J. Metal Edge Strips: Install where exposed edge of tile flooring meets carpet, wood, or other flooring that finishes flush with or below top of tile and no threshold is indicated.

3.4 ADJUSTING AND CLEANING

A. Remove and replace tile that is damaged or that does not match adjoining tile. Provide new matching units, installed as specified and in a manner to eliminate evidence of replacement.

B. Cleaning: On completion of placement and grouting, clean all ceramic tile surfaces so they are free of foreign matter.

1.Remove grout residue from tile as soon as possible.

2.Clean grout smears and haze from tile according to tile and grout manufacturer's written instructions but no sooner than 10 days after installation. Use only cleaners recommended by tile and grout manufacturers and only after determining that cleaners are safe to use by testing on samples of tile and other surfaces to be cleaned. Protect metal surfaces and plumbing fixtures from effects of cleaning. Flush surfaces with clean water before and after cleaning.

3.5 PROTECTION

A. Protect installed tile work with kraft paper or other heavy covering during construction period to prevent staining, damage, and wear. If recommended by tile manufacturer, CERAMIC TILING 093013 - 6 apply coat of neutral protective cleaner to completed tile walls and floors.

B. Prohibit foot and wheel traffic from tiled floors for at least seven days after grouting is completed.

C. Before final inspection, remove protective coverings and rinse neutral protective cleaner from tile surfaces.

3.6 INTERIOR CERAMIC TILE INSTALLATION SCHEDULE

A. Interior Floor Installations, Concrete Subfloor:

1.TCNA F114 and ANSI A108.1A : Cement mortar bed (thickset) without cleavage membrane or reinforcement; epoxy grout.

a. Ceramic Tile Type: <Insert tile-type designation>.

b. Bond Coat for Cured-Bed Method: Modified dry-set mortar.

c. Grout: Water-cleanable epoxy grout.

B. Interior Wall Installations, Masonry or Concrete:

1.TCNA W202 : Thinset mortar.

a. Ceramic Tile Type: <Insert tile-type designation>.

b. Thinset Mortar: Modified dry-set mortar.

c. Grout: Water-cleanable epoxy grout.

2.TCNA W243 <Insert designation>: Thinset mortar on gypsum board.

a. Ceramic Tile Type: <Insert tile-type designation>.

b. Thinset Mortar: Modified dry-set mortar.

c. Grout: Water-cleanable epoxy grout.

3.TCNA W245 or TCNA W248 <Insert designation>:

Thinset mortar on glass-mat, water-resistant gypsum backer board.

a. Ceramic Tile Type: <Insert tile-type designation>.

b. Thinset Mortar: Modified dry-set mortar.

c. Grout: Water-cleanable epoxy grout.

END OF SECTION 093013

CERAMIC TILING 093013 - 7

SECTION 095123 - ACOUSTICAL TILE CEILINGS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1.Acoustical tiles for interior ceilings.

2.Fully concealed, direct-hung, suspension systems.

3.Direct attachment of tiles to substrates with adhesive.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. Sustainable Design Submittals:

1.Product Data: For adhesives, indicating VOC content.

2.Laboratory Test Reports: For adhesives, indicating compliance with requirements for low-emitting materials.

C. Samples: For each exposed product and for each color and texture specified, 6 inches in size.

D. Samples for Verification: For each component indicated and for each exposed finish required, prepared on Samples of sizes indicated below:

1.Concealed Suspension-System Members: 6-inch long Sample of each type.

2.Exposed Moldings and Trim: Set of 6-inch long Samples of each type and color.

1.3 CLOSEOUT SUBMITTALS

A. Maintenance Data: For finishes to include in maintenance manuals.

1.4 MAINTENANCE MATERIAL SUBMITTALS

A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

1.Acoustical Ceiling Units: Full-size tiles equal to 2 percent of quantity installed.

1.5 DELIVERY, STORAGE, AND HANDLING

A. Deliver acoustical tiles, suspension-system components, and accessories to Project site and store them in a fully enclosed, conditioned space where they will be protected against damage from moisture, humidity, temperature extremes, direct sunlight, surface contamination, and other causes.

B. Before installing acoustical tiles, permit them to reach room temperature and a stabilized moisture content.

1.6 FIELD CONDITIONS

ACOUSTICAL TILE CEILINGS 095123 - 1

A. Environmental Limitations: Do not install acoustical tile ceilings until spaces are enclosed and weathertight, wet-work in spaces is complete and dry, work above ceilings is complete, and ambient temperature and humidity conditions are maintained at the levels indicated for Project when occupied for its intended use.

1.Pressurized Plenums: Operate ventilation system for not less than 48 hours before beginning acoustical tile ceiling installation.

PART 2 - PRODUCTS

2.1 SOURCE LIMITATIONS

A. Suspended Acoustical Tile Ceilings: Obtain each type of acoustical ceiling tile and its suspension system from single source from single manufacturer.

B. Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

Armstrong World Industries Conwed Corporation USG Ceilings

2.2 PERFORMANCE REQUIREMENTS

A. Surface-Burning Characteristics: Comply with ASTM E84;

testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.

1.Flame-Spread Index: Class A according to

ASTM E1264.

2.Smoke-Developed Index: 450 or less.

2.3 ACCESSORIES

A. Attachment Devices: Size for five times the design load indicated in ASTM C635/C635M, Table 1, "Direct Hung," unless otherwise indicated. Comply with seismic design requirements.

B. Wire Hangers, Braces, and Ties: Provide wires as follows:

1.Zinc-Coated, Carbon-Steel Wire:

ASTM A641/A641M, Class 1 zinc coating, soft temper.

2.Size: Wire diameter sufficient for its stress at three times hanger design load (ASTM C635/C635M, Table 1, "Direct Hung") will be less than yield stress of wire, but not less than 0.106-inch diameter wire.

2.4 ACOUSTICAL SEALANT

A. Acoustical Sealant: As specified in Section 079219

"Acoustical Joint Sealants."

ACOUSTICAL TILE CEILINGS 095123 - 2

2.5 MISCELLANEOUS MATERIALS

A. Acoustical Tile Adhesive: Type recommended in writing by acoustical tile manufacturer, bearing UL label for Class 0-25 flame spread.

1.Adhesives shall have a VOC content of 50 g/L or less.

2.Adhesive shall comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." The building concentration of formaldehyde shall not exceed half of the indoor recommended exposure limit or 33 mcg/cu. m and that of acetaldehyde shall not exceed 9 mcg/cu. m.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions, including structural framing and substrates to which acoustical tile ceilings attach or abut, with Installer present, for compliance with requirements specified in this and other Sections that affect ceiling installation and anchorage and for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.

B. Examine acoustical tiles before installation. Reject acoustical tiles that are wet, moisture damaged, or mold damaged.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 PREPARATION

A. Testing Substrates: Before adhesively bonding tiles to wet-placed substrates such as cast-in-place concrete or plaster, test and verify that moisture level is below tile manufacturer's recommended limits.

B. Measure each ceiling area and establish layout of acoustical tiles to balance border widths at opposite edges of each ceiling. Avoid using less-than-half-width tiles at borders unless otherwise indicated, and comply with layout shown on reflected ceiling plans.

C. Layout openings for penetrations centered on the penetrating items.

3.3 INSTALLATION OF SUSPENDED ACOUSTICAL TILE

CEILINGS

ACOUSTICAL TILE CEILINGS 095123 - 3

A. Install suspended acoustical tile ceilings according to ASTM C636/C636M and manufacturer's written instructions.

B. Suspend ceiling hangers from building's structural members and as follows:

1.Install hangers plumb and free from contact with insulation or other objects within ceiling plenum that are not part of supporting structure or of ceiling suspension system.

2.Splay hangers only where required to miss obstructions; offset resulting horizontal forces by bracing, countersplaying, or other equally effective means.

3.Secure wire hangers to ceiling suspension members and to supports above with a minimum of three tight turns. Connect hangers directly to structure or to inserts, eye screws, or other devices that are secure and appropriate for substrate and that will not deteriorate or otherwise fail due to age, corrosion, or elevated temperatures.

4.When steel framing does not permit installation of hanger wires at spacing required, install carrying channels or other supplemental support for attachment of hanger wires.

5.Do not attach hangers to steel roof deck. Attach hangers to structural members.

6.Space hangers not more than 48 inches o.c. along each member supported directly from hangers unless otherwise indicated; provide hangers not more than 8 inches from ends of each member.

7.Size supplemental suspension members and hangers to support ceiling loads within performance limits established by referenced standards.

C. Install edge moldings and trim of type indicated at perimeter of acoustical ceiling area and where necessary to conceal edges of acoustical tiles.

1.Apply acoustical sealant in a continuous ribbon concealed on back of vertical legs of moldings before they are installed.

2.Screw attach moldings to substrate at intervals not more than 16 inches o.c. and not more than 3 inches from ends. Miter corners accurately and connect securely.

ACOUSTICAL TILE CEILINGS 095123 - 4

D. Install suspension-system runners so they are square and securely interlocked with one another. Remove and replace dented, bent, or kinked members.

E. Install acoustical tiles in coordination with suspension system and exposed moldings and trim. Place splines or suspension-system flanges into kerfed edges of tiles so tile-to-tile joints are interlocked.

1.Fit adjoining tiles to form flush, tight joints. Scribe and cut tiles for accurate fit at borders and around penetrations through ceiling.

2.Hold tile field in compression by inserting leaf-type, spring-steel spacers between tiles and moldings, spaced 12 inches o.c.

3.4 INSTALLATION OF DIRECTLY ATTACHED ACOUSTICAL

TILE CEILINGS

A. Adhesive Installation: Install acoustical tile by bonding to substrate, using acoustical tile adhesive and procedure recommended in writing by tile manufacturer and as follows:

1.Wipe and prime ceiling.

2.Remove loose dust from backs of tiles by brushing.

3.Install splines in joints between tiles and maintain bottom surface to a uniform level. Shim tile or correct substrate as required to maintain levelness.

4.Maintain tight butt joints, aligned in both directions and coordinated with ceiling fixtures.

B. Install edge moldings and trim of type indicated at perimeter of acoustical tile ceiling area and where necessary to conceal edges of acoustical units.

3.5 ERECTION TOLERANCES

A. Suspended Ceilings: Install main and cross runners level to a tolerance of [1/4 inch in 12 feet, non-cumulative.

B. Moldings and Trim: Install moldings and trim to substrate and level with ceiling suspension system to a tolerance of 1/8 inch in 12 feet, non-cumulative.

3.6 ADJUSTING

A. Clean exposed surfaces of acoustical tile ceilings, including trim and edge moldings. Comply with manufacturer's written instructions for cleaning and touchup of minor finish damage.

B. Remove and replace tiles and other ceiling components that cannot be successfully cleaned and repaired to permanently eliminate evidence of damage.

END OF SECTION 095123

ACOUSTICAL TILE CEILINGS 095123 - 5

SECTION 096513 - RESILIENT BASE AND ACCESSORIES

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1.Vinyl base.

2.Vinyl molding accessories.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. Samples: For each exposed product and for each color and texture specified, not less than 12 inches long.

1.3 DELIVERY, STORAGE, AND HANDLING

A. Store resilient products and installation materials in dry spaces protected from the weather, with ambient temperatures maintained within range recommended by manufacturer, but not less than 50 deg F or more than 90 deg F.

1.4 FIELD CONDITIONS

A. Maintain ambient temperatures within range recommended by manufacturer, but not less than 70 deg F or more than 95 deg F, in spaces to receive resilient products during the following periods:

1.48 hours before installation.

2.During installation.

3.48 hours after installation.

B. After installation and until Substantial Completion, maintain ambient temperatures within range recommended by manufacturer, but not less than 55 deg F or more than 95 deg F.

C. Install resilient products after other finishing operations, including painting, have been completed.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1.Armstrong World Industries, Inc 2.Flexco 3.Johnsonite; a Tarkett company

B. Product Standard: ASTM F1861, Type TV (vinyl, thermoplastic).

1.Group: I (solid, homogeneous).

2.Style and Location:

a. Style A, Straight: Provide in areas with carpet.

RESILIENT BASE AND ACCESSORIES 096513 - 1

b. Style B, Cove: Provide in areas with resilient floor coverings.

C. Minimum Thickness: 0.125 inch.

D. Height: 4 inches.

E. Lengths: Cut lengths 48 inches long or coils in manufacturer's standard length.

F. Outside Corners: Preformed.

G. Inside Corners: Preformed.

H. Colors and Patterns: As indicated by manufacturer's designations.

2.2 INSTALLATION MATERIALS

A. Trowelable Leveling and Patching Compounds:

Latex-modified, portland-cement-based or blended hydraulic-cement-based formulation provided or approved by…