Addendum 5 21187.pdf

PDF 459 KB Posted

Attached to
511/21187. CAK; Albion Armory - Renovate Armory
Solicitation number
RFQ - 171 - 220000000461
Issued by
Calhoun County, Alden CDP, Michigan

About this file

This document is an Addendum to the solicitation for the Renovate Armory - Albion Armory project in Albion, Michigan. The project is located at the National Guard Armory Battery Albion Armory at 1023 N Clark Street, Albion, Michigan 49224. The addendum provides several clarifications and modifications to the original contract documents, including the omission of masonry block foam insulation, the use of solid surface material for the countertop and microwave shelf in the Break Room 145, the use of standard galvanized horizontal wire masonry block reinforcing, the change in masonry block wall thickness for the Women and Men's showers, and the specification of lacquered wood bench tops with prefinished metal stanchions for the wood finish metal supported benches in the Women and Men's locker room.

The contract opportunity is being solicited by the State of Michigan and involves the jurisdictions of Calhoun County and Alden CDP. No additional details are provided regarding pricing terms, set asides, incumbents, funding requirements and sources, or other salient information.

View the file

Other files

File Type Posted
Addendum 2 270500 DATA COMMUNICATION SYSTEM 220428.docx DOCX document
MtgAttend1 - 21187.pdf PDF
Advertisement 21187.pdf PDF
Addendum No.2 08122022 - 21187.pdf PDF
21-046 Albion Armory - A0.0 - Cover Sheet.pdf PDF
21-046 Albion Armory Civil Drawings.pdf PDF
MtgAttend1 - 21187_REVISED.pdf PDF
Addendum 3 06 Wood Plastics and Composites 21187.pdf PDF
Addendum No.6 08222022 - 21187.pdf PDF
Addendum 1 - 21187.pdf PDF
Albion Armory MEP Set.pdf PDF
Albion Armory Specification 14 of 15.pdf PDF
Albion Armory Specification 12 of 15.pdf PDF
Addendum 3 07 Thermal and Moisture Protection 21187.pdf PDF
Albion Armory Specification 11 of 15.pdf PDF
Albion Armory Specification 3 of 15.pdf PDF
Addendum 2 M-303 - MECHANICAL CONTROLS DIAGRAMS.pdf PDF
Albion Armory Specification 1 of 15.pdf PDF
Albion Armory Specification 7 of 15.pdf PDF
Addendum 3 21187.pdf PDF
Addendum 3 05 Metals 21187.pdf PDF
Albion Armory Draft Logs 11-23-21.pdf PDF
Albion Armory Specification 8 of 15.pdf PDF
Addendum 2 M-301 - MECHANICAL SCHEDULES_ —
Albion Armory Specification 4 of 15.pdf PDF
Addendum 3 08 Openings 21187.pdf PDF
Albion Armory Specification 6 of 15.pdf PDF
Specifications 21187.pdf PDF
Addendum 4 21187.pdf PDF
21-046 Albion Armory Architectural A4-S1 Set.pdf PDF
Albion Armory Draft Map 11-23-21.pdf PDF
Albion Armory Specification 13 of 15.pdf PDF
Albion Armory Specification 9 of 15.pdf PDF
Albion Armory Specification 15 of 15.pdf PDF
Albion Armory Specification 10 of 15.pdf PDF
Albion Armory Specification 2 of 15.pdf PDF
Albion Armory Specification 5 of 15.pdf PDF
21-046 Albion Armory Architectural A0-A3 Set.pdf PDF
Addendum 2 E-301 - ELECTRICAL DATA.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

August 18, 2022

Renovate Armory – Albion Armory

Addendum Number 05

Project Location National Guard Armory Battery Albion Armory 1023 N Clark Street Albion, Michigan 49224

Notice to Proposers

Receipt of this Addendum shall be acknowledged on the Proposal Form.

This Addendum forms part of the Contract documents for the above reference project and shall be incorporated integrally therewith.

Each proposer shall make necessary adjustments and submit their proposal with full knowledge of all modification, clarifications and supplemental data included therein. Where provisions of the following supplemental data differ from those of the original Contract Document, this Addendum shall govern.

Architectural Items

1. Please omit masonry block foam insulation, Green Seal 183, from the project, we will not be insulating the new 8” perimeter block cavities.

2. The countertop and microwave shelf in the Break Room 145 will be solid surface not plastic laminate, this includes the 4” back splash.

3. The horizontal wire masonry block reinforcing shall be standard galvanized and not epoxy coat, typical at all locations.

4. Please note that all 4” masonry block walls at the Women and Men’s showers will be changed to 6” masonry block walls to accommodate for the shower valves. All adjustments to the floor plan will be done post bid.

5. All Four (4) wood finish metal supported benches in the Women and Men’s locker room shall be lacquered wood bench tops with prefinished metal stanchions with base plates bolted to the concrete floor slab. Prefabricated benches are acceptable, verify size with architect.

End of Addendum Number 05