This document is an Addendum related to a state and local contract opportunity for the Albion Armory Renovation project in Calhoun County and Alden CDP, Michigan. The addendum includes mechanical schedules and legends, as well as mechanical control diagrams, for the renovation work. Key details include specifications for new and replacement HVAC equipment such as fans, rooftop units, dehumidifiers, cabinet unit heaters, air-cooled condensing units, and energy recovery ventilators. The addendum also includes details on grilles, diffusers, ductwork, and piping requirements. This is part of the overall 511/21187 CAK; Albion Armory - Renovate Armory contract opportunity.
The pricing terms, funding sources, and other contractual details were not included in the provided documentation. The addendum focuses solely on the technical mechanical specifications and requirements for the renovation project.
Text of this file
ABBREVIATIONS
VENTV
BALANCING VALVE
MECHANICAL CONTRACTOR
CU
CUH
C.W.
EA
LAT
M.C.
LWT
HWS
I.E.
CABINET UNIT HEATER
EXHAUST AIR
CONDENSING UNIT
COLD WATER
LEAVING AIR TEMPERATURE
LEAVING WATER DAMPER
HOT WATER SUPPLY
INVERT ELEVATION
WALL CLEAN OUT
YARD CLEAN OUT
VENT THRU ROOF
WATER CLOSET
3/8x3/8 WELDED WIRE MESH
WS WORK SINK
YCO
WCO
VTR
WC
WWM
ENTERING WATER TEMPERATURE
CA
CFM
COND
CSBV
ASME
A.H.J.
BTUH
AFF
FCO
EWC
EWT
EXIST.
FD
GD
F.S.E.C.
HP
HWR
CUBIC FEET PER MINUTE
COMBUSTION AIR
CONDENSATE
CIRCUIT SETTER
AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
AUTHORITY HAVING JURISDICTION
BRITISH THERMAL
UNITS PER HOUR
FIRE DAMPER
FOOD SERVICE EQUIPMENT CONTRACTOR
GREASE DUCT
HOT WATER RETURN
HORSE POWER
FLOOR CLEAN OUT
ELECTRIC WATER COOLER
EXISTING
EAT
ABOVE FINISHED FLOOR
ENTERING AIR TEMPERATURE
OA OUTSIDE AIR
SANITARY SEWER
SITE CONTRACTOR
STATIC PRESSURE
SERVICE SINK
STORM SEWER
SP
ST
SS
UH
UR URINAL
UNIT HEATER
RA / RAD
SA / SAD
SC
SAN
RETURN AIR / DUCT
SUPPLY AIR / DUCT
MOTORIZED DAMPERMD
STAINLESS STEELS/S
MEDIUM PRESSURE DUCTMPEC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
AL ACOUSTICALLY LINED
BOD BOTTOM OF DUCT
GAS LOAD SUMMARY
LOADS (CFH)EQUIPMENT DESCRIPTION
DWH-1:
NEW EQUIPMENT
199.0
1,925TOTAL CONNECTED LOAD (EX TO REMAIN, NEW, AND FUTURE):
EXISTING GAS METER LISTED CAPACITY IS BELOW NEW TOTAL CONNECTED LOAD, SO IT
IS ASSUMED NEW GAS METER WILL BE REQUIRED. FIELD VERIFY EXISTING GAS SERVICE
AND GAS METER CAPACITIES AND DETERMINE, ALONG WITH UTILITY COMPANY, IF
EXISTING GAS SERVICE AND EXISTING GAS METER CAN ACCOMMODATE ADDITIONAL GAS
LOAD OF NEW EQUIPMENT.
IF IT IS DETERMINED THAT THE EXISTING GAS SERVICE AND/OR EXISTING GAS METER
MUST BE REPLACED TO ACCOMMODATE ADDITIONAL GAS LOAD OF NEW EQUIPMENT,
NEW GAS SERVICE AND/OR GAS METER FURNISHED AND INSTALLED BY LOCAL UTILITY
COMPANY, ALL ASSOCIATED COSTS BY GENERAL CONTRACTOR. DEMO AND REPLACE
EXISTING GAS PIPING AS SHOWN ON PLANS.
EXISTING GAS METER 7" WC GAS SUPPLY PRESSURE DOWNSTREAM OF GAS METER.
REQUESTED 11" WC GAS SUPPLY PRESSURE DOWNSTREAM OF NEW GAS METER TO
ACCOMMODATE NEW MAKEUP AIR UNIT (REQUIRED GAS PRESSURE OF 7"-14" WC)
GAS PIPE DISTANCE FROM METER TO FURTHEST EQUIPMENT IS APPROX. 150'.
DWH-2: 199.0
EX BOILER B-1 (TO REMAIN):
EXISTING EQUIPMENT (FIELD VERIFY)
1,425
EXISTING EQUIPMENT TOTAL: 1,425
NEW EQUIPMENT TOTAL: 500.0
EX KITCHEN EQUIPMENT: VERIFY
HVAC DUCTWORK
MANUAL VOLUME DAMPER
MANUAL SPLITTER
S
V.D.
H HUMIDISTAT
14X20
SUPPLY AIR DIFFUSER
EXHAUST FAN
SUPPLY AIR DUCT SECTION,
FIRST FIGURE IS TOP
RETURN AIR DUCT SECTION,
FIRST FIGURE IS TOP
RETURN AIR DIFFUSER
VERTICAL FIRE DAMPER
20X14
20X14
T
S
SLOT DIFFUSER
ACOUSTICAL LINING (AL)
STANDARD BRANCH, NO SPLITTER
THERMOSTAT
THERMOSTAT WITH GUARD
TEMPERATURE SENSOR
FLEX CONNECTION
CHANGE IN ELEVATION,
RISE (R) DROP (D)
R
IS SIDE SHOWN
DUCT SIZE, FIRST FIGURE
CARBON DIOXIDE SENSORCO
ACOUSTICAL LINED RETURN AIR
DUCT WITH OPEN BELL MOUTH FITTING
TYPE A SUPPLY AIR DIFFUSER
WITH 475 CFM, 12" ROUND NECK
"A"-SA
475 CFM AL
TV
ELBOW WITH AERO DYNE HIGH
EFFICIENT TURNING VANES
RECTANGULAR RADIUS ELBOW WITH
R=1.5 W OR GREATER.
GAS SHUT-OFF VALVE
PIPE OR DUCT DROP
12"∅ NK.
GAS PRESSURE REGULATOR
T
R
W
R
P L
U R
I B
U E
S U
N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R
E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
DA
TE
IS
SU
ED
F
O R
ID
EN
TI
FI
CA
TI
O N
NO
SH
EE
T P.
M
DR
AW
N
CH
EC
KE
D
DA
TE
RE
VI
SI
O
N
DE
SC
AR
CH
P
RO
JE
CT
DT
M
B
PR
O
JE
CT
DM
VA
P
RO
JE
CT
BI
DS
CO
NS
TR
UC
TI
O
N
FI
NA
L
RE
CO
RD
A1
1/
1.
CA
K
D E
P A
R T
M E
N T
O F
T E
C H
N O
LO
G
Y , M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
R O
B E
R T
C . H
A
LL
, R A
, N C
A R
B , D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
AP
PR
O
VE
D
D ep ar tm en t o f M ili ta ry a nd
V et er a ns A ffa irs
A rm or y
M od ifi ca tio ns
A lb io n
A rm or y, A lb io n
, M ic h ig an
E as t C o u rt S tr ee t F lin t, M I 4
T
0-
8-w w w .s fa rc h .u s
H en ry S tr ee t M u sk eg o n
M I
T
1-
8-
/1
/2
:4
:3
P
M
M -3
A ut ho r
C he ck er
A pp ro ve r
D es ig ne r
-0
FAN SCHEDULE
TAG LOCATION
AIRFLOW
(CFM) E.S.P. (IN.WC.) SONES BHP (HP) HP VOLTS (V) PHASE MANUFACTURE MODEL COMMENT
EF-1 ADDITION ROOF 125 0.20 1.9 0.06 0.13 120 1 GREENHECK G-070-VG
RTU SCHEDULE
TAG
AIRFLOW
(CFM) E.S.P. (IN.WC.)
COOLING DATA HEATING DATA (STEAM)
OUT DOOR AIR
(CFM) % O.A.
ELECTRICAL DATA
EER REFRIGERENT MANUFACTURE MODEL COMMENT
TOTAL COOLING
(MBH) EAT DB (°F) EAT WB (°F) LAT DP (°F) LAT WB (°F) ΔT (°F) EAT (°F) LAT (°F) HEATING BTU
STEAM
PRESSURE
CONDENSATE
(LB/HR) FAN HP VOLTS (V) PHASE (∅) MCA (A) MOCP (A)
RTU-2 1,995 1.10 66 79.6 65.3 58.7 55.7 38 58.0 95.5 89.4 Btu/h 15.00 psi 101 315 15 2.0 208 3 35 50 11.5 R-410A AAON RQ-006-8-V-HA02-CHH
RTU-3 4,000 1.10 124 80.6 66.0 56.5 54.7 45 54.2 99.6 178.0 Btu/h 15.00 psi 202 1,000 25 3.0 208 3 54 70 11.5 R-410A AAON RN-011-8-0-HA09-CHH
RTU-4 4,000 1.10 160 77.3 63.8 55.0 53.0 44 65.9 109.4 65.0 Btu/h 15.00 psi 189 1,850 46 3.0 208 3 61 70 11.2 R-410A AAON RN-11-8-0-FA09-CHH
DEHUMIDIFIER SCHEDULE
WATER REMOVED
PER DAY (GAL) MCA (A) VOLTS (V) PHASE MANUFACTURE MODEL COMMENT
DH-1 70 5.1 120 1 QUEST 70
BLOWER COIL UNIT SCHEDULE
INDOOR
UNIT TAG MANUFACTURE
INDOOR UNIT
MODEL
OUTDOOR
UNIT TAG
OUTDOOR
UNIT MODEL
COOLING DATA HEATING DATA
% O.A. dB(A)
ELECTRICAL DATA
WEIGHT COMMENT
AIRFLOW
(CFM)
TOTAL COOLING
(MBH) EAT DB (F) EAT WB (F) LAT DB (F) LAT WB (F) EER SEER HEATING CFM
TOTAL HEATING
(MBH)
STEAM
PRESSURE
CONDENSATE
(LB/HR.) EAT (F) LAT (E) WEIGHT dB(A) MCA MOCP VOLTS PHASE
BCU-1 AAON H3-CRB-8-0 ACCU-1 CFA-005-A-A-8 1995 66.0 84 °F 69 °F 60 °F 59 °F 11.7 13.9 1950 CFM 111.7 5 psi 121 70 °F 124 °F 25 0 675 lb 0 7 15 208 3 675 lb
NOTES:
1. DEHUMIDIFICATION UNITS SHALL BE MOUNTED ABOVE USING THREADED RODS AND
PROVIDED WITH GALVANIZED DRAIN PAN UNDERNEATH SUSPENDED UNIT PER
MANUFACTUER'S RECOMENDATIONS.
2. DEHUMIDIFICATION UNITS SHALL BE PROVIDED WITH BUILT-IN DEHUMIDISTAT CONTROL.
3. DEHUMIDIFICATION UNIT POWER PROVIDED THRU 8' POWER CORD.
4. PIPE CONDENSATE TO FLOOR DRAIN BELOW UNIT.
NOTES:
1. ROOF CURBS AND EQUIPMENT TIE-DOWNS SHALL MEET ALL APPLICABLE WIND RESISTANCE
CODE REQUIREMENTS.
2. ALL EXHAUST FANS SHALL BE PROVIDED WITH DISCONNECT SWITCH.
3. PROVIDE INTERLOCKING KILL SWITCH FOR EXHAUST FAN.
AIR COOLED CONDENSING UNIT SCHEDULE
OUTDOOR
UNIT TAG MANUFACTURE
OUTDOOR
UNIT MODEL
INDOOR
UNIT TAG
INDOOR UNIT
MODEL
COOLING ELECTRICAL DATA
WEIGHT COMMENT
TOTAL COOLING
(MBH) EER SEER MCA MOCP VOLTS PHASE
ACCU-1 AAON CFA-005-A-A-8 ACCU-1 H3-CRB-8-0 66.0 11.7 13.9 22 35 208 3 413 lb
CABINET UNIT HEATER SCHEDULE
INDOOR
UNIT TAG MANUFACTURE MODEL
HEATING DATA ELECTRICAL DATA
WEIGHT COMMENT
AIRFLOW
(CFM)
TOTAL HEATING
(MBH)
STEAM
PRESSURE
CONDENSATE
(LB/HR) EAT (F) LAT (E) MCA MOCP VOLTS PHASE
CUH-1 MODINE 1-002-0-6-A-L-L-R-1-3 250 19.8 2 psi 21 60 °F 133 °F 0.25 1 120 1 85 lb
NOTES:
1. UNIT SHALL BE FLOOR MOUNTED WITH BOTTOM IN, TOP OUT AIR FLOW.
NOTES:
1. RTU-4 EQUIPT WITH INTEGREL ENERGY RECOVERY WHEEL.
2. ALL UNITS SHALL INCLUDE FACTORY FUSED DISCONNECT WITCH, MERVE 8 - 2" PLEATED FILTERS.
3. UNITS SHALL BE CONTROLLED BASED ON OCCUPANCY SENSORS LOCATED IN ASSOCIATED ZONES.
4. PROVIDE FACTORY ROOF CURB WITH CURB WIND CLIPS.
5. ALL ACCESS DOORS SHALL BE HINDGED WITH HANDEL ACCESS.
GRILLES AND DIFFUSERS SCHEDULE
TAG FACE SIZE NECK SIZE TYPE AIR PATTERN
LOCATION &
MOUNTING MATERIAL FINISH MANUFACTURE MODEL COMMENTS
A 24"x24" SEE PLAN SUPPLY 4-WAY CEILING STEEL WHITE TITUS TMS
B 24"x24" SEE PLAN RETURN/EXHAUST - CEILING STEEL WHITE TITUS PAR
C SEE PLAN SEE PLAN SUPPLY 2-WAY DUCT STEEL WHITE TITUS 300FL
D SEE PLAN SEE PLAN RETURN/EXHAUST - DUCT STEEL WHITE TITUS 350RL
E 12"x12" SEE PLAN SUPPLY 4-WAY CEILING STEEL WHITE TITUS TMS
F 12"x12" SEE PLAN RETURN/EXHAUST - CEILING STEEL WHITE TITUS PAR
NOTES:
1. CONTRACTOR SHALL VERIFY DIFFUSER OR GRILLE FRAME TYPE WITH MOUNTING SURFACE.
2. ALL VISIBLE SURFACES BEHIND DIFFUSER/GRILLE (INCLUDING DAMPERS) TO BE PAINTED FLAT BLACK.
3. BRANCH DUCTS SERVING DIFFUSER/GRILLE TO BE SAME SIZE AS DIFFUSER/GRILLE NECK SIZE, UNLESS
OTHERWISE NOTED.
4. PROVIDE EXTRA T-BAR FOR INSTALLATION OF 24x24 LAY-IN DIFFUSERS AND GRILLES INTO 48X24
CEILING GRID AS REQUIRED.
STEAM HEATING COIL - VENTILATION UNIT REPLACEMENT
TAG
AIRFLOW
(CFM)
HEATING DATA (STEAM)
SIZE
(L"xW"xH") MANUFACTURE MODEL COMMENTΔT (°F) EAT (°F) LAT (°F) HEATING BTU
STEAM
PRESSURE
CONDENSATE
(LB/HR)
SC-1 10,600 89 °F 40.0 129.0 1026.0 Btu/h 10.00 psi 1076 68x7.5x36 MODINE 5JA1002B
SC-2 10,600 89 °F 40.0 129.0 1026.0 Btu/h 10.00 psi 1076 68x7.5x36 MODINE 5JA1002B
INSIDE VRF UNIT SCHEDULE
INDOOR
UNIT TAG MANUFACTURE
INDOOR UNIT
MODEL
OUTDOOR
UNIT TAG
OUTDOOR
UNIT MODEL
COOLING DATA HEATING DATA
dB(A) WEIGHT
ELECTRICAL DATA
COMMENT
AIRFLOW
(CFM)
TOTAL COOLING
(MBH) EAT DB (°F) LAT DB (°F) HEATING CFM
TOTAL HEATING
(MBH) EAT (°F) LAT (°F) MCA MOCP VOLTS PHASE
FC-119 DAIKEN FXAQ12PVJU OU-1 RXLQ72TATJA 290 8.3 79 °F 52 °F 290 CFM 14.0 68 °F 112 °F 31 26 lb 0.4 15 208 1 1
FC-120 DAIKEN FXAQ12PVJU OU-1 RXLQ72TATJA 290 8.3 79 °F 52 °F 290 CFM 14.0 68 °F 112 °F 31 26 lb 0.4 15 208 1 1
FC-121 DAIKEN FXAQ12PVJU OU-1 RXLQ72TATJA 290 8.3 79 °F 52 °F 290 CFM 14.0 68 °F 112 °F 31 26 lb 0.4 15 208 1 1
FC-122 DAIKEN FXAQ07PVJU OU-1 RXLQ72TATJA 260 7.1 79 °F 58 °F 260 CFM 8.7 68 °F 98 °F 29 26 lb 0.3 15 208 1 1
OUTSIDE VRF UNIT SCHEDULE
TAG MANUFACTURE MODEL
COOLING ELECTRICAL DATA
WEIGHT COMMENT
TOTAL COOLING
(MBH) EER SEER MCA MOCP VOLTS PHASE
OU-1 DAIKEN RXLQ72TATJA 51.5 15.1 24 29.1 35 208 1 728 lb 1,2,3
NOTES:
1. PROVIDE DRAIN PAN HEATER.
2. PROVIDE 18" MOUNTING BASE EQUAL TO RECTORSEAL BIG FOOT B5551 STAND.
3. PROVIDE OPTIONAL WIND BAFFLES FOR LOW AMBIANT COOLING.
NOTES:
1. PROVIDE RECTORSEAL 120V MINI WHITE UNIVOLT CONDENSATE PUMP.
ENERGY RECOVERY VENTILATOR SCHEDULE
TAG
SUPPLY
AIRFLOW
(CFM)
EXHAUST AIR
FLOW (CFM)
SUPPLY ESP
(IN. WC.)
EXHAUST ESP
(IN. WC.)
SUMMER CONDITIONS WINTER CONDITIONS ELECTRICAL DATA
MANUFACTUR
E MODEL COMMENT
OUTDOOR AIR ROOM AIR FRESH AIR OUTDOOR AIR ROOM AIR FRESH AIR RAITED
HORSE
POWER
BREAK HORSE
POWER VOLTS PHASE MCA (A) MOCPTEMP DB (°F) TEMP WB (°F) TEMP DB (°F) TEMP WB (°F) TEMP DB (°F) TEMP WB (°F) TEMP DB (°F) TEMP WB (°F) TEMP DB (°F) TEMP WB (°F) TEMP DB (°F) TEMP WB (°F)
ERV-1 240 CFM 240 CFM 0.25 in-wg 0.25 in-wg 78 °F 66 °F 75 °F 62 °F 78 °F 66 °F 0 °F 0 °F 70 °F 51 °F 56 °F 43 °F 0.6 1 208 V 1 4.9 15 A RENEWAIRE EV450
NOTES:
1. PROVIDE FACTORY ROOF CURB WITH CURB WIND CLIPS.
2. PROVIDE 2" PLEATED MERV-8 OUTDOOR AIR FILTER, AND RETURN AIR FILTER.
S T
A T
E R
E V
IE
W
-1
-2
A D
D E
N D
U M
-1
-2
A1
A1
| Sheets |
| M-301 - MECHANICAL SCHEDULES & LEGENDS |
| M-303 - MECHANICAL CONTROLS DIAGRAMS |
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .