Addendum 2 M-303 - MECHANICAL CONTROLS DIAGRAMS.pdf
PDF 173 KB Posted
- Attached to
- 511/21187. CAK; Albion Armory - Renovate Armory
- Solicitation number
- RFQ - 171 - 220000000461
- Issued by
- Calhoun County, Alden CDP, Michigan
About this file
This document is an Addendum for the Mechanical Controls Diagrams related to the Albion Armory Renovation project in Albion, Michigan. The addendum provides detailed control diagrams, equipment schedules, and sequence of operations for the HVAC system upgrades, including air handling units, VAV boxes, exhaust fans, and associated components. It specifies the installation requirements for the direct digital control (DDC) system, such as the location of sensors, controllers, and relays, as well as the wiring and labeling protocols. The addendum also outlines the responsibilities of the mechanical contractor and the owner's control personnel for the implementation and commissioning of the control system.
The project is managed by the Department of Military and Veterans Affairs (DMVA) for the State of Michigan. The renovations are taking place at the Albion Armory, located in Albion, Michigan, which is within Calhoun County. The mechanical control system upgrades are part of the overall armory renovation effort, and the addendum provides detailed technical information to ensure the proper integration of the HVAC controls.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE: N.T.S.
NOTE: CONTROL CONTRACTOR TO VERIFY THE LOCATION OF THE OUTDOOR AIR SENSOR
CONTROL CABINET DETAILS
DDC-1
DIN RAIL RELAY SOCKET & RELAY AS
REQUIRED AND (1)
SPARE
DIN RAIL TERMINAL BLOCKS AS REQUIRED FOR
ALL 24V POWER AND COMMON & (4)
SPARE
DIN RAIL CIRCUIT BREAKER FOR EACH
CONTROLLER
4x4x24" WIREWAY
AC/DC CONVERTER, ACDC-1
T-1
ENCLOSURE ENC-1
1.5X2.25 SLOTTED WIRE DUCT VERTICAL
1.0x1.5 SLOTTED WIRE DUCT HORIZONTAL
DIN RAIL TYP
NEW 3/4" EMT FOR CONTROL WIRES AS
REQUIRED
CIRCUIT FROM POWER PANEL
T-2 VAV
TRANSFORMER
T-2 VAV
TRANSFORMER DDC-1 DDC-1
GENERAL DDC NOTES:
REFER TO DDC EQUIPMENT ELEVATION DETAIL ON THIS SHEET FOR DDC CONTROL ENCLOSURE LAYOUT.
CONNECT EXHAUST FANS EF-1 & EF-2 TO NEW RELAY AND OCCUPANCY SENSOR (OCCUPANCY SENSOR INSTALLED BY ELECTRICAL) TO ACTIVATE EXHAUST FAN VIA ISOLATED RELAY CONTACTS IN OCCUPANCY SENSOR. COORDINATE WITH ELECTRICAL.
INSTALL DDC CONTROL WIRES FOR CONDENSER IN 3/4" CONDUIT ROUTED THRU OVERHEAD SOFFIT IN CORRIDOR. COORDINATE W/
ELECTRICAL, MECHANICAL AND PLUMBING.
MECHANICAL EQUIPMENT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. REFER TO SHEET M2 FOR MORE DETAIL.
ROUTE (2) 4 CONDUCTOR, 18 GA. WIRING AND 2 CONDUCTOR 18 GA. SHIELDED FROM ENC-1 TO CONDENSER CU-1 FOR SUCTION PRESSURE
AND DIGITAL SCROLL COMPRESSOR CONTROL.
NOTES
1. PRIOR TO ANY INSTALLATION OF DDC EQUIPMENT OR DDC WIRING, CONTRACTOR SHALL REQUEST A DDC PRECONSTRUCTION MEETING WITH DMVA IN-HOUSE TECHNICIAN TO DISCUSS CONSTRUCTION SCHEDULING, PRECISE
DDC EQUIPMENT LOCATIONS, STARTUPS, LABELING PROCEDURES, AND COMMISSIONING.
2. CONTRACTOR MUST FOLLOW A DDC WIRE COLOR SCHEDULE FOR ALL DDC WIRING INSTALLED. THIS SCHEDULE WILL BE
AGREED UPON DURING THE PRECONSTRUCTION MEETING.
3. CONTRACTOR TO INSTALL A MINIMUM 3/4" CONDUIT FOR ALL DDC WIRING. CONTRACTOR IS ALLOWED TO INSTALL J-HOOKS 4' O.C. FOR DDC CONTROL WIRING ONLY IN AREAS ABOVE A SUSPENDED CEILING. ALL CONDUIT IN WALLS TO
BE STUBBED INTO CEILING SPACE.
4. CONTRACTOR SHALL PULL ALL DDC WIRING AS SHOWN ON DDC FLOOR PLAN AND DDC EQUIPMENT SCHEDULE. ALL WIRES SHALL BE LABELED WITH A LABEL MAKER APPROVED BY DMVA ENGINEERING. NO HAND WRITTEN LABELS WILL BE ALLOWED. ALL LABELS LOCATED IN ENCLOSURE ENC-1 MUST BE PLACED 6" DOWN ON WIRE ONCE INSIDE THE
ENCLOSURE, DO NOT LOCATE LABEL AT THE END OF WIRE.
5. ALL INPUT/OUTPUT CONTROL WIRES TO BE LON RATED, SEE SPECIFICATIONS.
6. DDC SEQUENCE AND PROGRAMMING WILL BE COMPLETED BY DMVA IN-HOUSE TECHNICIAN, SEE SPECIFICATIONS.
7. INSTALL TEMPERATURE SENSORS, TEMP-1, 60" AFF.
8. INSTALL OCCUPANCY SENSORS, OCC-1, 6" FROM CEILING.
9. INSTALL OAT-1 ON NORTH FACING EXTERIOR WALL, MAKE WEATHERTIGHT.
10. PRINT COPY OF DDC WIRE COLOR SCHEDULE AND SCHEMATIC AND SECURE TO THE BACK OF THE DOOR IN ENC-1.
11. PROVIDE AND INSTALL ALL END DEVICES SHOWN.
NOTES:
1. CONTRACTOR TO FURNISH AND INSTALL MATERIALS IN SCHEDULE. WIRE SHOWN TO BE PULLED INTO ENCLOSURES, LABELED AND COILED AT EACH END.
2. SUBSTITUTIONS SHALL BE REVIEWED AND APPROVED BY DMVA ENGINEERING PRIOR TO INSTALLATION.
3. ACTUATOR ACT-1 MODEL NUMBER DEPENDS ON DEVICE SIZE. INSTALL PROPERLY SIZED TORQUE ACTUATOR BASED ON MANUFACTURER'S RECOMMENDATIONS.
DDC EQUIPMENT SCHEDULE
BASIS OF DESIGN SERVICE QTY / WIRE SIZE
TO EQUIPMENT
NOTES
ROOM TEMP
AIRSTREAM TEMP
OAT
DDC
DESCRIPTION
ROOM TEMPERATURE SENSOR
PROGRAMMABLE CONTROLLER
DUCT/EQUIP TEMPERATURE SENSOR
OUTDOOR AIR TEMP SENSOR
LOCATION
SEE LAYOUT, WALL MOUNTED 60" AFF
RETURN DUCT AFTER FRESH AIR
BLDG EXTERIOR
DDC ENCLOSURE
ENC-1CATNET - CLI-FTCATNET INTERFACE W/ LON CARD ONE PER BUILDING, ENC-1
KELE - RET2620 DDC EQUIPMENT ENCLOSUREDDC ENCLOSURE MECHANICAL ROOM -
BAPI - BA/10K-3-B4
BAPI - BA/10K-3-O-EU
3 CONDUCTOR / 18 GA.
WATER TEMPPIPE TEMPERATURE SENSOR SUPPLY DUCTBAPI - BA/10K3-S
3 CONDUCTOR / 18 GA.
4 CONDUCTOR / 18 GA.
NO SUBSTITUTIONS
(2) SINGLE POLE DOUBLE THROW 15A
SMART CONTROLS - EC240
LABEL
TEMP-1-AREA
TEMP-2-AHU# or RTU#
OAT-1
DDC-1
CATNET
ENC-1
TEMP-3-AHU# or RTU#
MARK
TEMP-1
TEMP-2
OAT-1
DDC-1
DDC-2
ENC-1
TEMP-3
AIR PROD. & CONTROLS - T-PB-202-0TRANSFORMER w/ OUTLET DDC ENCLOSURE -T-1-ENC#T-1
NO SUBSTITUTIONS
CS-1 AHU/PUMPS/EXHAUST FANSACI - A/MSCSCURRENT SENSOR VARIES
RELAY VARIESRELAY-1 RIB - RIBU1C MECHANICAL EQUIP
2 CONDUCTOR / 18 GA.
CS-1-(DEVICE NAME)
(VARIES ON DEVICE)
DIN RAIL RELAY SOCKET MECH ROOMRELAY-2 VERIS - VBD1B-F MECHANICAL EQUIP
DIN RAIL RELAY SPDT MECH ROOMRELAY-3 VERIS - VMD1B-F24A MECHANICAL EQUIP
2 CONDUCTOR / 18 GA.
DIN RAIL DDC ENCLOSURE / RTUDIN RAIL KELI - BAM-1000 MECHANICAL EQUIP
SEE DETAILS FOR EXACT LOCATION
DDC ENCLOSURE EQUIPMENT
CIRCUIT BREAKER FOR CONTROLLERBRKR - CBI ELECTRIC - QL-2 DDC ENCLOSURE / RTU
BAPI - BA/10K-3-D-18"
WIRE DUCT - SLOTTED WIRE DUCT IBOCO - T1E-2222W MECHANICAL EQUIP DDC ENCLOSURE
SEE DETAILS FOR EXACT LOCATION
PROGRAMMABLE CONTROLLER
SEE DETAILS FOR EXACT LOCATION2 CONDUCTOR / 18 GA.
SINGLE POLE DOUBLE THROW 2A
18 INCHES, TEMP. AVERAGING
3 CONDUCTOR / 18 GA.
SD-1 AHU/RTUAIR PRODUCTS & CONTROLS - SL-2000-PSMOKE DETECTOR RETURN DUCT BEFORE FRESH AIR
3 CONDUCTOR / 18 GA.
SD-1
TERMINAL BLOCK DDC ENCLOSURE / RTUTBLCK KELE - CDU4N MECHANICAL EQUIP
CO2-1 CO2VERIS - CDEDUCT CO2 SENSOR RETURN DUCT
3 CONDUCTOR / 18 GA.
CO2-1-AHU#
2 CONDUCTOR / 18 GA. SHIELD, 2 CONDUCTOR / 18 GA. PWR
OR APPROVED EQUAL
RELAY VARIESRELAY-4 RIB - RIB2421SB AHU/RTU FANS & ALL PUMPS
2 CONDUCTOR / 18 GA.
(VARIES ON DEVICE)
SINGLE POLE DOUBLE THROW 2A
ENC-1CATNET - HMI CH-2CATNET WEBSERVER -WEBSERVERDDC-3 NO SUBSTITUTIONS
ENC-1CATNET - CMI-485INTERFACE MODBUS DDC ENCLOSURE -MODBUSDDC-4 NO SUBSTITUTIONS
ONE PER BUILDING, ENC-1
OCC-1 ROOM OCCUPACNYWATTSTOPPER - CX100OCCUPANY SENSOR SEE LAYOUT, WALL MOUNTED 6" FROM CEILINGOCC-1-RM#
ACDC-1 ACDC-1 AC TO DC VOLTAGE CONVERTER ACI - PS1.5 OCCUPACNY SENSORS DDC ENCLOSURE
2 CONDUCTOR / 18 GA., 2 CONDUCTOR / 18 GA. PWR
KELE - RET2620 DDC EQUIPMENT ENCLOSUREDDC ENCLOSURE MECHANICAL ROOM - NO SUBSTITUTIONSENC-2ENC-2
ACT-1 CONTROL VALVESKMC CONTROLS - MEP-7552DAMPER ACTUATOR VARIESACT-1-(DEVICE NAME) 2 CONDUCTOR / 18 GA. SHIELD, 2 CONDUCTOR / 18 GA. PWR
ACT-2 DAMPERSKMC CONTROLS - MEP-4252V1_
" & 3_
" VALVE ACTUATOR VARIESACT-2-(DEVICE NAME) 2 CONDUCTOR / 18 GA. SHIELD, 2 CONDUCTOR / 18 GA. PWR
KELE - RET2620 DDC EQUIPMENT ENCLOSUREDDC ENCLOSURE MECHANICAL ROOM - NO SUBSTITUTIONSENC-3ENC-3
SEQUENCE OF OPERATION FOR EQUIPMENT
GENERAL
OCCUPANCY SENSORS (OCC-1) WILL HAVE AN ADJUSTABLE SOFTWARE SET POINT (IN MINUTES) TO TELL THE CONTROL SYSTEM THE DESIRED DURATION OF THE OCCUPIED MODE EACH TIME THE SENSOR IS ACTIVATED.
MECHANICAL COOLING AND OUTDOOR AIR DAMPERS WILL NOT BE UTILIZED WITHOUT PROOF OF SUPPLY FAN
OPERATION THRU ITS RESPECTIVE CURRENT SENSING SWITCH.
AIR HANDLING UNIT (RTU-2 & RTU-3)
SPACE TEMPERATURE WILL BE DIRECTLY CONTROLLED BY THE ASSOCIATED SPACE TEMPERATURE CONTROLLERS. THE DISCHARGE AIR TEMPERATURE OF THE AHU WILL BE CONTROLLED DEMAND FROM THE
SPACE TEMPERATURE SENSOR.
AIR HANDLING UNIT (RTU-2 & RTU-3)
SPACE TEMPERATURE WILL BE DIRECTLY CONTROLLED BY THE ASSOCIATED SPACE TEMPERATURE CONTROLLERS. THE DISCHARGE AIR TEMPERATURE OF THE AHU WILL BE CONTROLLED BASED DEMAND FROM SPACE TEMPERATURE SENSOR. THE BYPASS DAMPER SHALL MODULATE OPEN TO MAINTAIN AIR FLOW WHEN THERE IS NO DEMAND BY THE SPACE TEMPERATURE SENSOR & MAKE UP AIR IS REQUIRED FOR SHOWER
ROOMS.
OCCUPIED MODE
OCCUPIED MODE WILL BE INITIATED THRU EITHER THE BUILDINGS OCCUPANCY SCHEDULE, AS SET THRU THE
WEB SERVER USER INTERFACE, OR BY THE BUILDINGS OCCUPANCY
SENSORS (OCC-1).
DURING THIS MODE, THE SUPPLY FAN WILL RUN CONTINUOUSLY AND THE MIXED AIR DAMPERS WILL OPEN TO THEIR PROGRAMMABLE MINIMUM POSITION SET POINT ( 10.0%, ADJUSTABLE) TO PROVIDE VENTILATION AIR.
SHOULD THE RETURN AIR CO2 LEVEL RISE ABOVE THE PROGRAMMABLE HIGH LIMIT OF 800 PPM (ADJUSTABLE) THE OUTDOOR AIR DAMPER WILL BE PROPORTIONALLY OPENED, TO A MAXIMUM POSITION OF 50%, TO REDUCE
THE CO2 LEVEL.
HEATING MODE WILL BE ALLOWED WHENEVER THE OUTDOOR AIR TEMPERATURE IS BELOW THE HEATING LOCKOUT SET POINT (60.0 F, ADJUSTABLE). COOLING MODE WILL BE ALLOWED WHENEVER THE OUTDOOR AIR
TEMPERATURE IS ABOVE THE COOLING LOCKOUT SET POINT (40.0 F, ADJUSTABLE).
DURING HEATING MODE THE STEAM VALVE WILL BE MODULATED TO MEET THE ZONE REQUIREMENTS.
MECH EQUIPMENTFREEZESTAT COOLING COILACI - FS-4FR-1-AHU# or RTU#FR-1 3 CONDUCTOR / 18 GA.
ACT-3 DAMPERSKMC CONTROLS - MEP-4552V1" - 3" VALVE ACTUATOR VARIESACT-3-(DEVICE NAME) 2 CONDUCTOR / 18 GA. SHIELD, 2 CONDUCTOR / 18 GA. PWR
RIB - PSH200A-LVCTRANSFORMER DDC ENCLOSURE -T-2-ENC#T-2 VAV CONTROLLERS
CIRCON - VAV-332-IMVTERMINAL UNIT CONTROLLER SEE MECHANICAL SHEETS 2 CONDUCTOR / 18 GA. PWRVAV-#-LOCATIONVAV-1-20 HVAC EQUIP NO SUBSTITUTIONS, POWER WIRE FROM T-2
ACI - A/LP2-3-10DUCT PRESSURE SENSOR MAIN SUPPLY DUCT 4 CONDUCTOR / 18 GA. SHIELDDP-1DP-1 MECHANICAL EQUIP
WHEN OUTDOOR AIR CONDITIONS ARE APPROPRIATE AN ECONOMIZER CYCLE WILL BE UTILIZED FOR FREE COOLING. THE MIXED AIR DAMPERS WILL BE MODULATED TO MAINTAIN THE ZONE REQUIREMENTS. DURING THIS
MODE THE SUPPLY AIR WILL NOT BE ALLOWED TO FALL BELOW A LOW LIMIT OF 55.0 F.
WHEN OUTDOOR AIR CONDITIONS ARE NOT APPROPRIATE FOR FREE COOLING, THE
MECHANICAL COOLING WILL BE STAGED WITH MINIMUM ON AND OFF TIMES TO MEET THE ZONE REQUIREMENTS.
SHOULD THE DUCT MOUNT SMOKE DETECTOR (RTU-3 & RTU-4) SENSE PRODUCTS OF COMBUSTION, OR THE LOW TEMPERATURE FREEZE-STAT OPEN ON LOW TEMPERATURE, THE SUPPLY FAN WILL BE DEENERGIZED AND ALL
DAMPERS AND DEVICES WILL GO TO THEIR RESPECTIVE FAIL-SAFE POSITION.
UNOCCUPIED MODE
DURING THIS MODE THE OUTDOOR AIR DAMPER WILL REMAIN CLOSED, THE RETURN AIR DAMPER WILL REMAIN
OPEN AND THE SUPPLY FAN CYCLED AS NECESSARY.
A CALL FOR HEATING WILL CAUSE THE SUPPLY FAN TO BE ENERGIZED AND THE HOT WATER VALVE TO BE OPENED TO 100% UNTIL THE SPACE TEMPERATURE RISES THREE (3.0) DEGREES F ABOVE THE UNOCCUPIED
HEATING SET POINT.
A CALL FOR COOLING WILL CAUSE THE MECHANICAL COOLING AND SUPPLY FAN TO BE ENERGIZED UNTIL THE SPACE TEMPERATURE FALLS THREE (3.0) DEGREES F BELOW THE UNOCCUPIED COOLING SET POINT. THE SUPPLY FAN WILL CONTINUE TO RUN FOR A PERIOD OF TWO (2.0) MINUTES AFTER THE MECHANICAL COOLING IS
DE-ENERGIZED.
ALARMS
AN ALARM CONDITION WILL BE REPORTED TO THE WEB SERVER USER INTERFACE FOR THE FOLLOWING;
LOW SPACE TEMPERATURE
HIGH SPACE TEMPERTAURE
AIR HANDLING UNIT SUPPLY FAN FAILURE
AIR HANDLING UNIT FREEZE-STAT TRIPPED
AIR HANDLING UNIT SMOKE DETECTOR TRIPPED
AIR HANDLING UNIT LOW SUPPLY AIR TEMPERATURE
BOILER FAILURE
DOMESTIC HOT WATER CIRCULATING PUMP FAILURE
MECHANICAL ROOM LOW SPACE TEMPERATURE
MECHANICAL ROOM EXHAUST FAN FAILURE
GENERAL CONTROL SCOPE AND IMPLEMENTATION NOTES:
1. MECHANICAL CONTRACTOR (OR CONTROLS WIRING SUBCONTRACTOR UNDER MC) SHALL BE RESPONSIBLE FOR PROVIDING ALL CONTROL DEVICES (SENSORS, CONTROL VALVES, CONTROL DAMPERS, RELAYS, ETC.), ALL CONTROLLERS (PROGRAMMABLE UNITARY CONTROLLERS AND TERMINAL UNIT CONTROLLERS), ALL CONTROL PANEL ENCLOSURES FOR CONTROLLERS, TWO (2) OPERATOR WORKSTATIONS (LAPTOP PC COMPUTER), NETWORK
INTEGRATION SOFTWARE (ECHELON LONWORKS BASED), AND ALL LOW VOLTAGE WIRING.
2. OWNER'S CONTROL PERSONNEL WILL PROVIDE ALL PROGRAMMING OF CONTROL SYSTEM, WILL PROVIDE ALL LOW VOLTAGE WIRE TERMINATIONS AT INDIVIDUAL CONTROLLERS AND CONTROLLED EQUIPMENT/DEVICES (ROOFTOP UNITS, VAV BOXES (IF APPLICABLE), RELAYS, STARTERS, CURRENT TRANSDUCERS, SPACE SENSORS, ETC.); MECHANICAL CONTRACTOR REQUIRED TO CARRY $25,000 ALLOWANCE UNDER THEIR CONTRACT FOR
OWNER'S CONTROL PERSONNEL.
3. MECHANICAL CONTRACTOR (OR CONTROLS WIRING SUBCONTRACTOR UNDER MC) SHALL BE RESPONSIBLE FOR ALL LOW VOLTAGE FIELD WIRING FROM EQUIPMENT, SENSORS AND CONTROLLED DEVICES TO CONTROLLERS. ALL CONTROL WIRING SHALL BE WHITE, SHALL BE CLEARLY LABELED AT CONTROL PANEL AND CONTROLLED DEVICE, AND SHALL BE TERMINATED WITH A 5'-0" LONG COILED END FOR OWNER'S CONTROL PERSONNEL TO TERMINATE AS
REQUIRED.
4. OWNER'S CONTROL PERSONNEL SHALL BE RESPONSIBLE FOR CREATING CONTROL WIRING DIAGRAMS FOR ALL CONTROL SYSTE,S, FOR ALL FINAL TERMINATIONS OF CONTROL WIRING, FOR ALL COMMISSIONING OF CONTROL SYSTEMS AND CONTROLLED DEVICES, AND FOR ALLOWNER TRAINING OF CONTROL SYSTEM; MECHANICAL CONTRACTOR OR THEIR CONTROLS WIRING SUB-CONTRACTOR SHALL NOT BE RESPONSIBLE FOR PROGRAMMING, WIRING TERMINATIONS, COMMISSIONING OR OWNER TRAINING.
F re e z e s ta t
F a n S ta tu s
DI
F a n S ta rt
/S to p
DO DI
R E
L A
Y -4
C S
-1
F R
-1
RA SA
DM
D a m p e r
O p e n
AO
A C
T -2
ERV-1
V R
F s ta tu s
DI
VRF
DO
V R
F E n a b le
C S
-1
R E
L A
Y -1
VRF
OU-1
E n a b le
DO
S ta tu s
DI
C S
-1
R E
L A
Y -4
DEHUMIDIFIER
DEHUMIDIFIER
EAOA
DM
D a m p e r
O p e n
AO
A C
T -2
F a n S ta tu s
F a n S ta rt
/S to p
DO DI
R E
L A
Y -4
C S
-1
F C
-1
F C
-1
F C
-1
F C
-1
E n a b le
DO
S ta tu s
DI
C S
-1
R E
L A
Y -4
EXHAUST FAN
EXHAUST FAN
S A
T e m p e ra tu re
F re e z e s ta t
F a n S ta tu s
AIDI
V a lv e
O p e n
AODI
S m o k e D e te c to r (R
T U
-3 o n ly
F a n S ta rt
/S to p
DO DI
M A
T e m p e ra tu re
AI
S D
-1
T E
M P
-2
R E
L A
Y -4
C S
-1
F R
-1
T E
M P
-3
A C
T -1
RA
DM
H tg
C o ils
FA
SA
C lg
C o ils
AI
C O
M o n it o r C
O
-1
DM
D a m p e r
O p e n
AO
A C
T -2
D a m p e r
O p e n
AO
A C
T -2
RTU-3, RTU-4 & BCU-1
D u c t P re ss u re
AI
D P
-1
S A
T e m p e ra tu re
F re e z e s ta t
F a n S ta tu s
AIDI
V a lv e
O p e n
AODI
S m o k e
D e te c to r
F a n S ta rt
/S to p
DO DI
M A
T e m p e ra tu re
AI
S D
-1
T E
M P
-2
R E
L A
Y -4
C S
-1
F R
-1
T E
M P
-3
A C
T -1
RA
DM
H tg
C o ils
FA
SA
DM
D a m p e r
O p e n
AO
A C
T -2
D a m p e r
O p e n
AO
A C
T -2
GYM RTU'S
D u c t P re ss u re
AI
D P
-1
AI
C O
M o n it o r C
O
-1
S A
T e m p e ra tu re
F re e z e s ta t
F a n S ta tu s
AIDI
V a lv e
O p e n
AODI
S m o k e
D e te c to r
F a n S ta rt
/S to p
DO DI
M A
T e m p e ra tu re
AI
S D
-1
T E
M P
-2
R E
L A
Y -4
C S
-1
F R
-1
T E
M P
-3
A C
T -1
RA
DM
H tg
C o ils
FA
SA
DM
D a m p e r
O p e n
AO
A C
T -2
D a m p e r
O p e n
AO
A C
T -2
RTU-4
D u c t P re ss u re
AI
D P
-1
AI
C O
M o n it o r C
O
-1
EA
FA
DM
D a m p e r
O p e n
AO
A C
T -2
TA
EA
F a n S ta tu s
F a n S ta rt
/S to p
DO DI
R E
L A
Y -4
C S
-1 e n e rg y w h e e l S ta tu s e n e rg y w h e e l S ta rt
/S to p
DO DI
R E
L A
Y -4
C S
-1 c lg
C o ils
M502
P L
U R
I B
U E
S U
N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R
E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
DA
TE
IS
SU
ED
F
O R
ID
EN
TI
FI
CA
TI
O N
NO
SH
EE
T P.
M
DR
AW
N
CH
EC
KE
D
DA
TE
RE
VI
SI
O
N
DE
SC
AR
CH
P
RO
JE
CT
DT
M
B
PR
O
JE
CT
DM
VA
P
RO
JE
CT
BI
DS
CO
NS
TR
UC
TI
O
N
FI
NA
L
RE
CO
RD
A1
1/
1.
CA
K
D E
P A
R T
M E
N T
O F
T E
C H
N O
LO
G
Y , M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
R O
B E
R T
C . H
A
LL
, R A
, N C
A R
B , D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
AP
PR
O
VE
D
D ep ar tm en t o f M ili ta ry a nd
V et er a ns A ffa irs
A rm or y
M od ifi ca tio ns
A lb io n
A rm or y, A lb io n
, M ic h ig an
E as t C o u rt S tr ee t F lin t, M I 4
T
0-
8-w w w .s fa rc h .u s
H en ry S tr ee t M u sk eg o n
M I
T
1-
8-
/1
/2
:4
:3
P
M
M -3
A ut ho r
C he ck er
A pp ro ve r
D es ig ne r
-0
A
D D
E N
D U
M
-1 -2
A1
| Sheets |
| M-301 - MECHANICAL SCHEDULES & LEGENDS |
| M-303 - MECHANICAL CONTROLS DIAGRAMS |
File details come from the government source that posted it. Updated .