Addendum 3 08 Openings 21187.pdf
PDF 545 KB Posted
- Attached to
- 511/21187. CAK; Albion Armory - Renovate Armory
- Solicitation number
- RFQ - 171 - 220000000461
- Issued by
- Calhoun County, Alden CDP, Michigan
About this file
This document is an Addendum for a state and local contract opportunity to Renovate the Armory in Albion, Michigan. The contract is being managed by the state of Michigan and involves Calhoun County and the Alden CDP jurisdiction.
The Addendum provides detailed specifications for the renovation work, including requirements for interior standard steel doors and frames, flush wood doors, access doors and frames, aluminum-framed storefronts, aluminum windows, and door hardware. Key details include performance requirements, fabrication and installation instructions, approved manufacturers, and finishing specifications. The renovation project does not specify any set-asides or incumbent contractors. Pricing information is not included, but the document indicates the project will be funded through state and local sources.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RENOVATE ARMORY - ALBION ARMORY
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes:
1.Interior standard steel doors and frames.
B. Related Requirements:
1.Section 087100 "Door Hardware" for door hardware for hollow-metal doors.
1.2 DEFINITIONS
A. Minimum Thickness: Minimum thickness of base metal without coatings in accordance with NAAMM-HMMA 803 or ANSI/SDI A250.8.
1.3 COORDINATION
A. Coordinate anchorage installation for hollow-metal frames.
Furnish setting drawings, templates, and directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items with integral anchors. Deliver such items to Project site in time for installation.
B. Coordinate requirements for installation of door hardware, electrified door hardware, and access control and security systems.
1.4 ACTION SUBMITTALS
A. Product Data: For each type of product.
1.Include construction details, material descriptions, core descriptions, and finishes.
B. Shop Drawings: Include the following:
1.Elevations of each door type.
2.Details of doors, including vertical- and horizontal-edge details and metal thicknesses.
3.Frame details for each frame type, including dimensioned profiles and metal thicknesses.
4.Locations of reinforcement and preparations for hardware.
5.Details of each different wall opening condition.
6.Details of electrical raceway and preparation for electrified hardware, access control systems, and security systems.
7.Details of anchorages, joints, field splices, and connections.
8.Details of accessories.
9.Details of moldings, removable stops, and glazing.
C. Product Schedule: For hollow-metal doors and frames, prepared by or under the supervision of supplier, using same reference numbers for details and openings as those
HOLLOW METAL DOORS AND FRAMES 081113 - 1
on Drawings. Coordinate with final door hardware schedule.
1.5 CLOSEOUT SUBMITTALS
A. Record Documents: For fire-rated doors, list of door numbers and applicable room name and number to which door accesses.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver hollow-metal doors and frames palletized, packaged, or crated to provide protection during transit and Project-site storage. Do not use nonvented plastic.
1.Provide additional protection to prevent damage to factory-finished units.
B. Deliver welded frames with two removable spreader bars across bottom of frames, tack welded to jambs and mullions.
C. Store hollow-metal doors and frames vertically under cover at Project site with head up. Place on minimum 4-inch-high wood blocking. Provide minimum 1/4-inch space between each stacked door to permit air circulation.
PART 2 - PRODUCTS
2.1 MANUFACTURES
A. Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
Steelcraft Republic Steel Corporation
2.2 PERFORMANCE REQUIREMENTS
A. Windborne-Debris Impact Resistance: Passes
ASTM E1886 missile-impact and cyclic-pressure tests in accordance with ASTM E1996 for Wind Zone 3 for enhanced protection.
B. Thermally Rated Door Assemblies: Provide door assemblies with U-factor of not more than 0.40 deg Btu/F x h x sq. ft. when tested in accordance with ASTM C1363 or ASTM E1423.
2.3 INTERIOR STANDARD STEEL DOORS AND FRAMES
A. Construct hollow-metal doors and frames to comply with standards indicated for materials, fabrication, hardware locations, hardware reinforcement, tolerances, and clearances, and as specified.
B. Standard-Duty Doors and Frames: ANSI/SDI A250.8, Level 1; ANSI/SDI A250.4, Level C. At locations indicated in the Door and Frame Schedule.
1.Doors:
HOLLOW METAL DOORS AND FRAMES 081113 - 2
a. Type: As indicated in the Door and Frame Schedule.
b. Thickness: 1-3/4 inches.
c. Face: Uncoated steel sheet, minimum thickness of 0.032 inch.
d. Edge Construction: Model 2, Seamless.
e. Edge Bevel: Provide manufacturer's standard beveled or square edges.
f. Core:Polyurethane.
2.Frames:
a. Materials: Uncoated steel sheet, minimum thickness of 0.042 inch.
b. Sidelite Frames: Fabricated from same thickness material as adjacent door frame.
c. Construction: Full profile welded.
3.Exposed Finish: Prime.
C. Maximum-Duty Doors and Frames: ANSI/SDI A250.8, Level 4; ANSI/SDI A250.4, Level A. At locations indicated in the Door and Frame Schedule.
1.Doors:
a. Type: As indicated in the Door and Frame
Schedule.
b. Thickness: 1-3/4 inches.
c. Face: Uncoated steel sheet, minimum thickness of 0.067 inch.
d. Edge Construction: Model 2, Seamless.
e. Edge Bevel: Provide manufacturer's standard beveled or square edges.
f. Core: Manufacturer's standard.
2.Frames:
a. Materials: Uncoated steel sheet, minimum thickness of 0.067 inch.
b. Construction: Full profile welded.
3.Exposed Finish: Prime.
2.4 BORROWED LITES
A. Fabricate of uncoated steel sheet, minimum thickness of
0.042 inch.
B. Construction: Full profile welded.
C. Fabricate in one piece except where handling and shipping limitations require multiple sections. Where frames are fabricated in sections due to shipping or handling limitations, provide alignment plates or angles at each joint, fabricated of metal of same or greater thickness as metal as frames.
HOLLOW METAL DOORS AND FRAMES 081113 - 3
D. Provide countersunk, flat- or oval-head exposed screws and bolts for exposed fasteners unless otherwise indicated.
2.5 HOLLOW-METAL PANELS
A. Provide hollow-metal panels of same materials, construction, and finish as adjacent door assemblies.
2.6 FRAME ANCHORS
A. Jamb Anchors:
1.Type: Anchors of minimum size and type required by applicable door and frame standard, and suitable for performance level indicated.
2.Quantity: Minimum of three anchors per jamb, with one additional anchor for frames with no floor anchor. Provide one additional anchor for each 24 inches of frame height above 7 feet.
3.Postinstalled Expansion Anchor: Minimum 3/8-inch- diameter bolts with expansion shields or inserts, with manufacturer's standard pipe spacer.
B. Floor Anchors: Provide floor anchors for each jamb and mullion that extends to floor.
C. Material: ASTM A879/A879M, Commercial Steel (CS), 04Z coating designation; mill phosphatized.
1.For anchors built into exterior walls, steel sheet complying with ASTM A1008/A1008M or ASTM A1011/A1011M; hot-dip galvanized in accordance with ASTM A153/A153M, Class B.
2.7 MATERIALS
A. Cold-Rolled Steel Sheet: ASTM A1008/A1008M, Commercial Steel (CS), Type B; suitable for exposed applications.
B. Hot-Rolled Steel Sheet: ASTM A1011/A1011M, Commercial Steel (CS), Type B; free of scale, pitting, or surface defects; pickled and oiled.
C. Inserts, Bolts, and Fasteners: Hot-dip galvanized in accordance with ASTM A153/A153M.
D. Power-Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated, fabricated from corrosion-resistant materials, with clips or other accessory devices for attaching hollow-metal frames of type indicated.
E. Glazing: Comply with requirements in Section 088000 "Glazing."
2.8 FABRICATION
A. Hollow-Metal Frames: Fabricate in one piece except where handling and shipping limitations require multiple sections.
Where frames are fabricated in sections, provide alignment
HOLLOW METAL DOORS AND FRAMES 081113 - 4
plates or angles at each joint, fabricated of metal of same or greater thickness as frames.
1.Sidelite Frames: Provide closed tubular members with no visible face seams or joints, fabricated from same material as door frame. Fasten members at crossings and to jambs by welding.
2.Provide countersunk, flat- or oval-head exposed screws and bolts for exposed fasteners unless otherwise indicated.
3.Door Silencers: Except on weather-stripped frames, drill stops to receive door silencers as follows. Keep holes clear during construction.
a. Single-Door Frames: Drill stop in strike jamb to receive three door silencers.
b. Double-Door Frames: Drill stop in head jamb to receive two door silencers.
B. Hardware Preparation: Factory prepare hollow-metal doors and frames to receive templated mortised hardware, and electrical wiring; include cutouts, reinforcement, mortising, drilling, and tapping in accordance with ANSI/SDI A250.6, the Door Hardware Schedule, and templates.
1.Reinforce doors and frames to receive nontemplated, mortised, and surface-mounted door hardware.
2.Comply with BHMA A156.115 for preparing hollow-metal doors and frames for hardware.
C. Glazed Lites: Provide stops and moldings around glazed lites where indicated. Form corners of stops and moldings with mitered hairline joints.
1.Provide stops and moldings flush with face of door, and with beveled stops unless otherwise indicated.
2.Provide fixed frame moldings on outside of exterior and on secure side of interior doors and frames.
Provide loose stops and moldings on inside of hollow-metal doors and frames.
3.Coordinate rabbet width between fixed and removable stops with glazing and installation types indicated.
4.Provide stops for installation with countersunk flat-or oval-head machine screws spaced uniformly not more than 9 inches o.c. and not more than 2 inches o.c. from each corner.
2.9 STEEL FINISHES
A. Prime Finish: Clean, pretreat, and apply manufacturer's standard primer.
HOLLOW METAL DOORS AND FRAMES 081113 - 5
1.Shop Primer: Manufacturer's standard, fast-curing, lead- and chromate-free primer complying with ANSI/SDI A250.10; recommended by primer manufacturer for substrate; compatible with substrate and field-applied coatings despite prolonged exposure.
PART 3 - EXECUTION
3.1 PREPARATION
A. Remove welded-in shipping spreaders installed at factory.
Restore exposed finish by grinding, filling, and dressing, as required to make repaired area smooth, flush, and invisible on exposed faces. Touch up factory-applied finishes where spreaders are removed.
B. Drill and tap doors and frames to receive nontemplated, mortised, and surface-mounted door hardware.
3.2 INSTALLATION
A. Install hollow-metal doors and frames plumb, rigid, properly aligned, and securely fastened in place. Comply with approved Shop Drawings and with manufacturer's written instructions.
B. Hollow-Metal Frames: Comply with ANSI/SDI A250.11.
1.Set frames accurately in position; plumbed, aligned, and braced securely until permanent anchors are set.
After wall construction is complete, remove temporary braces without damage to completed Work.
a. Where frames are fabricated in sections, field splice at approved locations by welding face joint continuously; grind, fill, dress, and make splice smooth, flush, and invisible on exposed faces. Touch-up finishes.
b. Install frames with removable stops located on secure side of opening.
2.Floor Anchors: Secure with postinstalled expansion anchors.
a. Floor anchors may be set with power-actuated fasteners instead of postinstalled expansion anchors if so indicated and approved on Shop Drawings.
3.Solidly pack mineral-fiber insulation inside frames.
4.In-Place Concrete or Masonry Construction: Secure frames in place with postinstalled expansion anchors.
5.Installation Tolerances: Adjust hollow-metal frames to the following tolerances:
HOLLOW METAL DOORS AND FRAMES 081113 - 6
a. Squareness: Plus or minus 1/16 inch, measured at door rabbet on a line 90 degrees from jamb perpendicular to frame head.
b. Alignment: Plus or minus 1/16 inch, measured at jambs on a horizontal line parallel to plane of wall.
c. Twist: Plus or minus 1/16 inch, measured at opposite face corners of jambs on parallel lines, and perpendicular to plane of wall.
d. Plumbness: Plus or minus 1/16 inch, measured at jambs at floor.
C. Hollow-Metal Doors: Fit and adjust hollow-metal doors accurately in frames, within clearances specified below.
1.Non-Fire-Rated Steel Doors: Comply with
ANSI/SDI A250.8.
D. Glazing: Comply with installation requirements in Section 088000 "Glazing" and with hollow-metal manufacturer's written instructions.
3.3 REPAIR
A. Prime-Coat Touchup: Immediately after erection, sand smooth rusted or damaged areas of prime coat and apply touchup of compatible air-drying, rust-inhibitive primer.
B. Touchup Painting: Cleaning and touchup painting of abraded areas of paint are specified in painting Sections.
END OF SECTION 081113
HOLLOW METAL DOORS AND FRAMES 081113 - 7
SECTION 081416 - FLUSH WOOD DOORS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1.Factory finishing flush wood doors.
2.Factory fitting flush wood doors to frames and factory machining for hardware.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product, including the following:
1.Door core materials and construction.
2.Door edge construction 3.Door face type and characteristics.
4.Factory-machining criteria.
5.Factory-finishing specifications.
B. Shop Drawings: Indicate location, size, and hand of each door; elevation of each type of door; construction details not covered in Product Data; and the following:
1.Door schedule indicating door location, type, size, fire protection rating, and swing.
2.Door elevations, dimension and locations of hardware, lite and louver cutouts, and glazing thicknesses.
3.Details of frame for each frame type, including dimensions and profile.
4.Dimensions and locations of blocking for hardware attachment.
5.Dimensions and locations of mortises and holes for hardware.
6.Clearances and undercuts.
7.Requirements for veneer matching.
8.Doors to be factory finished and application requirements.
9.Apply AWI Quality Certification Program label to
Shop Drawings.
C. Samples for Initial Selection: For factory-finished doors.
1.3 CLOSEOUT SUBMITTALS
A. Special warranties.
B. Quality Standard Compliance Certificates: AWI Quality
Certification Program certificates.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Comply with requirements of referenced standard and manufacturer's written instructions.
B. Package doors individually in cardboard cartons, and wrap bundles of doors in plastic sheeting.
FLUSH WOOD DOORS 081416 - 1
C. Mark each door on bottom rail with opening number used on Shop Drawings.
1.5 FIELD CONDITIONS
A. Environmental Limitations:
1.Do not deliver or install doors until spaces are enclosed and weathertight, wet-work in spaces is complete and dry, and HVAC system is operating and maintaining temperature and relative humidity at levels designed for building occupants for the remainder of construction period.
2.Do not deliver or install doors until building is enclosed and weathertight, wet work is complete, and HVAC system is operating and maintaining temperature between 60 and 90 deg F and relative humidity between 43 and 70 percent during remainder of construction period.
1.6 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace doors that fail in materials or workmanship within specified warranty period.
1.Failures include, but are not limited to, the following:
a. Delamination of veneer.
b. Warping (bow, cup, or twist) more than 1/4 inch in a 42-by-84-inch section.
c. Telegraphing of core construction in face veneers exceeding 0.01 inch in a 3-inch span.
2.Warranty also includes installation and finishing that may be required due to repair or replacement of defective doors.
3.Warranty Period for Solid-Core Interior Doors: Life of installation.
PART 2 - PRODUCTS
2.1 FLUSH WOOD DOORS AND FRAMES, GENERAL
A. Quality Standard: In addition to requirements specified, comply with AWI/AWMAC/WI's "Architectural Woodwork Standards."
1.Provide labels and certificates from AWI certification program indicating that doors comply with requirements of grades specified.
2.2 SOLID-CORE FLUSH WOOD DOORS
A. Interior Doors, Solid Core Insert drawing designation:
FLUSH WOOD DOORS 081416 - 2
1.Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
a. Lambton Doors
b. Oshkosh Door Company
c. Poncraft Door Company
d. Weyerhauser
2.Architectural Woodwork Standards Grade:
Premium.
3.NWMA Industry Standard 1.S. 1-80 4.Exposed Vertical Edges: Hardwood edges for staining to match faces.
5.Core for Non-Fire-Rated Doors:
a. Either glued wood stave or WDMA I.S. 10 structural composite lumber.
6.Construction:
a. Five plies, hot-pressed or cold-pressed bonded (vertical and horizontal edging is bonded to core), with entire unit abrasive planed before faces and crossbands are applied.
2.3 FABRICATION
A. Factory fit doors to suit frame-opening sizes indicated.
1.Comply with clearance requirements of referenced quality standard for fitting unless otherwise indicated.
B. Factory machine doors for hardware that is not surface applied.
1.Locate hardware to comply with DHI-WDHS-3.
2.Comply with final hardware schedules, door frame
Shop Drawings, ANSI/BHMA-156.115-W, and hardware templates.
3.Coordinate with hardware mortises in metal frames, to verify dimensions and alignment before factory machining.
C. Transom and Side Panels:
1.Fabricate matching panels with same construction, exposed surfaces, and finish as specified for associated doors.
2.Finish bottom edges of transoms and top edges of rabbeted doors same as door stiles.
3.Fabricate door and transom panels with full-width, solid-lumber meeting rails.
FLUSH WOOD DOORS 081416 - 3
4.Provide factory-installed spring bolts for concealed attachment into jambs of metal door frames.
D. Openings: Factory cut and trim openings through doors.
1.Light Openings: Trim openings with moldings of material and profile indicated.
2.Glazing: Factory install glazing in doors indicated to be factory finished. Comply with applicable requirements in Section 088000 "Glazing."
2.4 FACTORY FINISHING
A. Comply with referenced quality standard for factory finishing.
1.Complete fabrication, including fitting doors for openings and machining for hardware that is not surface applied, before finishing.
2.Finish faces, all four edges, edges of cutouts, and mortises.
3.Stains and fillers may be omitted on bottom edges, edges of cutouts, and mortises.
B. Factory finish doors.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine doors and installed door frames, with Installer present, before hanging doors.
1.Verify that installed frames comply with indicated requirements for type, size, location, and swing characteristics and have been installed with level heads and plumb jambs.
2.Reject doors with defects.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Hardware: For installation, see Section 087100 "Door Hardware."
B. Install doors to comply with manufacturer's written instructions and referenced quality standard, and as indicated.
C. Install frames level, plumb, true, and straight.
1.Shim as required with concealed shims. Install level and plumb to a tolerance of 1/8 inch in 96 inches.
2.Anchor frames to anchors or blocking built in or directly attached to substrates.
a. Secure with countersunk, concealed fasteners and blind nailing.
FLUSH WOOD DOORS 081416 - 4
b. Use fine finishing nails for exposed fastening, countersunk and filled flush with woodwork.
1) For factory-finished items, use filler matching finish of items being installed.
D. Job-Fitted Doors:
1.Align and fit doors in frames with uniform clearances and bevels as indicated below.
a. Do not trim stiles and rails in excess of limits set by manufacturer or permitted for fire-rated doors.
2.Machine doors for hardware.
3.Seal edges of doors, edges of cutouts, and mortises after fitting and machining.
4.Clearances:
a. Provide 1/8 inch at heads, jambs, and between pairs of doors.
b. Where threshold is shown or scheduled, provide 1/4 inch from bottom of door to top of threshold unless otherwise indicated.
5.Bevel non-fire-rated doors 1/8 inch in 2 inches at lock and hinge edges.
E. Factory-Finished Doors: Restore finish before installation if fitting or machining is required at Project site.
3.3 ADJUSTING
A. Operation: Rehang or replace doors that do not swing or operate freely.
B. Finished Doors: Replace doors that are damaged or that do not comply with requirements. Doors may be repaired or refinished if Work complies with requirements and shows no evidence of repair or refinishing.
END OF SECTION 081416
FLUSH WOOD DOORS 081416 - 5
SECTION 083113 - ACCESS DOORS AND FRAMES
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Access doors and frame.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
PART 2 - PRODUCTS
2.1 ACCESS DOORS AND FRAMES
A. Flush Access Doors with Exposed Flanges :
1. MIlcor M, Activar TM, or Babcock Davis BNT
2. Description: Face of door flush with frame, with exposed flange and concealed hinge.
3. Uncoated Steel Sheet for Door: Nominal 0.060 inch (1.52 mm), 16 gage, factory primed.
4. Frame Material: Same material, thickness, and finish as door.
2.2 MATERIALS
A. Steel Plates, Shapes, and Bars: ASTM A36/A36M.
B. Steel Sheet: Uncoated or electrolytic zinc coated, ASTM A879/A879M, with cold-rolled steel sheet substrate complying with ASTM A1008/A1008M, Commercial Steel (CS), exposed.
C. Frame Anchors: Same material as door face.
D. Inserts, Bolts, and Anchor Fasteners: Hot-dip galvanized steel according to ASTM A153/A153M or ASTM F2329.
2.3 FABRICATION
A. General: Provide access door and frame assemblies manufactured as integral units ready for installation.
ACCESS DOORS AND FRAMES 083113 - 1
B. Metal Surfaces: For metal surfaces exposed to view in the completed Work, provide materials with smooth, flat surfaces without blemishes. Do not use materials with exposed pitting, seam marks, roller marks, rolled trade names, or roughness.
C. Doors and Frames: Grind exposed welds smooth and flush with adjacent surfaces. Furnish mounting holes, attachment devices and fasteners of type required to secure access doors to types of supports indicated.
D. Latch and Lock Hardware:
1. Quantity: Furnish number of latches and locks required to hold doors tightly closed.
2.4 FINISHES
A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.
B. Painted Finishes: Comply with coating manufacturer's written instructions for cleaning, conversion coating, and applying and baking finish.
1. Factory Primed: Apply manufacturer's standard, lead- and chromate-free, universal primer immediately after surface preparation and pretreatment.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Comply with manufacturer's written instructions for installing access doors and frames.
3.3 ADJUSTING
A. Adjust doors and hardware, after installation, for proper operation.
END OF SECTION 083113
ACCESS DOORS AND FRAMES 083113 - 2
SECTION 084313 - ALUMINUM-FRAMED STOREFRONTS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
1.Include construction details, material descriptions, dimensions of individual components and profiles, and finishes.
B. Sustainable Design Submittals:
1.Product Data: For sealants, indicating VOC content.
2.Laboratory Test Reports: For sealants, indicating compliance with requirements for low-emitting materials.
3.Environmental Product Declaration: For each product.
4.Third-Party Certifications: For each product.
5.Third-Party Certified Life Cycle Assessment: For each product.
C. Shop Drawings: For aluminum-framed storefronts. Include plans, elevations, sections, full-size details, and attachments to other work.
1.Include details of provisions for assembly expansion and contraction and for draining moisture occurring within the assembly to the exterior.
2.Include full-size isometric details of each type of vertical-to-horizontal intersection of aluminum-framed storefronts, showing the following:
a. Joinery, including concealed welds.
b. Anchorage.
c. Expansion provisions.
d. Glazing.
e. Flashing and drainage.
3.Show connection to and continuity with adjacent thermal, weather, air, and vapor barriers.
D. Samples for Initial Selection: For units with factory-applied color finishes.
E. Samples for Verification: For each type of exposed finish required, in manufacturer's standard sizes.
1.3 INFORMATIONAL SUBMITTALS
A. Qualification Data:
1.For Installer
ALUMINUM-FRAMED STOREFRONTS 084313 - 1
B. Energy Performance Certificates: For aluminum-framed storefronts, accessories, and components, from manufacturer.
1.Basis for Certification: NFRC-certified energy performance values for each aluminum-framed storefront.
C. Product Test Reports: For aluminum-framed storefronts, for tests performed by manufacturer and witnessed by a qualified testing agency.
D. Sample Warranties: For special warranties.
1.4 CLOSEOUT SUBMITTALS
A. Maintenance Data: For aluminum-framed storefronts to include in maintenance manuals.
1.5 QUALITY ASSURANCE
A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer and that employs a qualified glazing contractor for this Project who is certified under the North American Contractor Certification Program (NACC) for Architectural Glass & Metal (AGM) contractors.
B. Testing Agency Qualifications: Qualified in accordance with ASTM E699 for testing indicated and acceptable to Owner and Architect.
C. Product Options: Information on Drawings and in Specifications establishes requirements for aesthetic effects and performance characteristics of assemblies. Aesthetic effects are indicated by dimensions, arrangements, alignment, and profiles of components and assemblies as they relate to sightlines, to one another, and to adjoining construction.
1.6 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace components of aluminum-framed storefronts that do not comply with requirements or that fail in materials or workmanship within specified warranty period.
1.Failures include, but are not limited to, the following:
a. Structural failures, including, but not limited to, excessive deflection.
b. Noise or vibration created by wind and thermal and structural movements.
c. Deterioration of metals and other materials beyond normal weathering.
d. Water penetration through fixed glazing and framing areas.
ALUMINUM-FRAMED STOREFRONTS 084313 - 2
e. Failure of operating components.
2.Warranty Period: 10 years from date of Substantial Completion.
B. Special Finish Warranty, Factory-Applied Finishes:
Standard form in which manufacturer agrees to repair finishes or replace aluminum that shows evidence of deterioration of factory-applied finishes within specified warranty period.
1.Deterioration includes, but is not limited to, the following:
a. Cracking, checking, peeling, or failure of paint to adhere to bare metal.
2.Warranty Period:10 years from date of Substantial Completion.
PART-2 PRODUCTS
1.7 MANUFACTURES
A. Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
Kawneer ‘Trifab 451T’ Framing System 500T wide style Doors
U S Aluminum Tubelite Inc
1.8 PERFORMANCE REQUIREMENTS
A. General Performance: Comply with performance requirements specified, as determined by testing of aluminum-framed storefronts representing those indicated for this Project without failure due to defective manufacture, fabrication, installation, or other defects in construction.
1.Aluminum-framed storefronts shall withstand movements of supporting structure, including, but not limited to, twist, column shortening, long-term creep, and deflection from uniformly distributed and concentrated live loads.
2.Failure also includes the following:
a. Thermal stresses transferring to building structure.
b. Glass breakage.
c. Noise or vibration created by wind and thermal and structural movements.
d. Loosening or weakening of fasteners, attachments, and other components.
e. Failure of operating units.
ALUMINUM-FRAMED STOREFRONTS 084313 - 3
B. Structural Loads:
1.Wind Loads: As indicated on Drawings.
C. Structural: Test in accordance with ASTM E330/E330M as follows:
1.When tested at positive and negative wind-load design pressures, storefront assemblies do not evidence deflection exceeding specified limits.
2.When tested at 150 percent of positive and negative wind-load design pressures, storefront assemblies, including anchorage, do not evidence material failures, structural distress, or permanent deformation of main framing members exceeding
0.2 percent of span.
3.Test Durations: As required by design wind velocity, but not less than 10 seconds.
D. Water Penetration under Static Pressure: Test in accordance with ASTM E331 as follows:
1.No evidence of water penetration through fixed glazing and framing areas when tested in accordance with a minimum static-air-pressure differential of 20 percent of positive wind-load design pressure, but not less than 10 lbf/sq. ft..
2.Maximum Water Leakage: No uncontrolled water penetrating assemblies or water appearing on assemblies' normally exposed interior surfaces from sources other than condensation. Water leakage does not include water controlled by flashing and gutters, or water that is drained to exterior.
E. Energy Performance: Certified and labelled by manufacturer for energy performance as follows:
1.Thermal Transmittance (U-factor):
a. Fixed Glazing and Framing Areas: U-factor for the system of not more than 0.41 Btu/sq.
ft. x h x deg F as determined in accordance with NFRC 100.
2.Solar Heat Gain Coefficient (SHGC):
a. Fixed Glazing and Framing Areas: SHGC for the system of not more than 0.40 as determined in accordance with NFRC 200.
3.Air Leakage:
a. Fixed Glazing and Framing Areas: Air leakage for the system of not more than 0.06 cfm/sq. ft. at a static-air-pressure differential of 6.24 lbf/sq. ft.when tested in accordance with ASTM E283.
ALUMINUM-FRAMED STOREFRONTS 084313 - 4
4.Condensation Resistance Factor (CRF):
a. Fixed Glazing and Framing Areas: CRF for the system of not less than 55 as determined in accordance with AAMA 1503.
F. Noise Reduction: Test in accordance with ASTM E90, with ratings determined by ASTM E1332, as follows.
1.Outdoor-Indoor Transmission Class: Minimum 34.
G. Blast Resistance:
1.Hazard Rating: [No Break] [No Hazard] [Minimal Hazard] [Very Low Hazard] [Low Hazard] [Moderate Hazard] [High Hazard] in accordance with ASTM F2912, tested in accordance with
ASTM F1642/F1642M.
2.Performance Condition: [1] [2] [3a] [3b] [4] [5] in accordance with GSA-TS01.
H. Ballistics Resistance, UL 752: [Listed and labeled as] [Level 1] [Level 2] [Level 3] [Level 4] [Level 5] [Level 6] [Level 7] [Level 8] [Level 9] [Level 10] [Level 1-SG] [Level 2-SG] [Level 3-SG] [Level 4-SG] [Level 5-SG] [Level 6-SG] [Level 7-SG] [Level 8-SG] [Level 9-SG] [Level 10-SG] when tested in accordance with UL 752.
I. Ballistics Resistance, ASTM F1233: [Class/Level HG1] [Class/Level HG2] [Class/Level HG3] [Class/Level HG4] [Class/Level SMG] [Class/Level R1] [Class/Level R2] [Class/Level R3] [Class/Level R4-AP] [Class/Level R5] [Class/Level SH1] [Class/Level SH2] when tested in accordance with ASTM F1233.
J. Ballistics Resistance, HPW-TP-0500.03: [A] [B] [C] [D] [E] when tested in accordance with HPW-TP-0500.03.
K. Ballistics Resistance, SD-STD-01.01: [R] [SH] when tested in accordance with SD-STD-01.01.
L. Ballistics Resistance, NIJ STD-0108.01: [Level I] [Level IIA] [Level II] [Level IIIA] [Level III] [Level IV] when tested in accordance with NIJ STD-0108.01.
M. Windborne-Debris Impact Resistance: Passes ASTM E1886 missile-impact and cyclic-pressure tests in accordance with ASTM E1996 for Wind Zone 3 for enhanced protection.
N. Thermal Movements: Allow for thermal movements resulting from ambient and surface temperature changes.
1.Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.
1.9 GLAZING
A. Glazing: Comply with Section 088000 "Glazing."
ALUMINUM-FRAMED STOREFRONTS 084313 - 5
B. Glazing Gaskets: Manufacturer's standard sealed-corner pressure-glazing system of black, resilient elastomeric glazing gaskets, setting blocks, and shims or spacers.
C. Glazing Sealants: As recommended by manufacturer.
1.Sealant shall have a VOC content of 250 g/L or less.
2.Sealant shall comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." The building concentration of formaldehyde shall not exceed half of the indoor recommended exposure limit, or 33 mcg/cu. m, and that of acetaldehyde shall not exceed 9 mcg/cu. m.
1.10 MATERIALS
A. Sheet and Plate: ASTM B209.
B. Extruded Bars, Rods, Profiles, and Tubes: ASTM B221.
C. Structural Profiles: ASTM B308/B308M.
1.11 ACCESSORIES
A. Fasteners and Accessories: Manufacturer's standard corrosion-resistant, nonstaining, nonbleeding fasteners and accessories compatible with adjacent materials.
1.Use self-locking devices where fasteners are subject to loosening or turning out from thermal and structural movements, wind loads, or vibration.
2.Reinforce members as required to receive fastener threads.
3.Use exposed fasteners with countersunk Phillips screw heads, finished to match framing system.
B. Anchors: Three-way adjustable anchors with minimum adjustment of 1 inch that accommodate fabrication and installation tolerances in material and finish compatible with adjoining materials and recommended by manufacturer.
1.Concrete and Masonry Inserts: Hot-dip galvanized cast-iron, malleable-iron, or steel inserts complying with ASTM A123/A123M or ASTM A153/A153M requirements.
C. Bituminous Paint: Cold-applied asphalt-mastic paint containing no asbestos, formulated for 30-mil thickness per coat.
1.12 FABRICATION
A. Form or extrude aluminum shapes before finishing.
ALUMINUM-FRAMED STOREFRONTS 084313 - 6
B. Weld in concealed locations to greatest extent possible to minimize distortion or discoloration of finish. Remove weld spatter and welding oxides from exposed surfaces by descaling or grinding.
C. Fabricate components that, when assembled, have the following characteristics:
1.Profiles that are sharp, straight, and free of defects or deformations.
2.Accurately fitted joints with ends coped or mitered.
3.Physical and thermal isolation of glazing from framing members.
4.Accommodations for thermal and mechanical movements of glazing and framing to maintain required glazing edge clearances.
5.Provisions for field replacement of glazing from interior.
6.Fasteners, anchors, and connection devices that are concealed from view to greatest extent possible.
D. Mechanically Glazed Framing Members: Fabricate for flush glazing without projecting stops.
E. Storefront Framing: Fabricate components for assembly using head-and-sill-receptor system with shear blocks at intermediate horizontal members.
F. After fabrication, clearly mark components to identify their locations in Project in accordance with Shop Drawings.
1.13 ALUMINUM FINISHES
A. Clear Anodic Finish: AAMA 611, AA-M12C22A41, Class I, 0.018 mm or thicker.
1.14 SOURCE QUALITY CONTROL
A. Structural Sealant: Perform quality-control procedures complying with ASTM C1401 recommendations, including, but not limited to, assembly material qualification procedures, sealant testing, and assembly fabrication reviews and checks.
PART 2 - EXECUTION
2.1 EXAMINATION
A. Examine areas, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
2.2 INSTALLATION, GENERAL
A. Comply with manufacturer's written instructions.
B. Do not install damaged components.
ALUMINUM-FRAMED STOREFRONTS 084313 - 7
C. Fit joints to produce hairline joints free of burrs and distortion.
D. Rigidly secure nonmovement joints.
E. Install anchors with separators and isolators to prevent metal corrosion and electrolytic deterioration and to prevent impeding movement of moving joints.
F. Seal perimeter and other joints watertight unless otherwise indicated.
G. Metal Protection:
1.Where aluminum is in contact with dissimilar metals, protect against galvanic action by painting contact surfaces with materials recommended by manufacturer for this purpose or by installing nonconductive spacers.
2.Where aluminum is in contact with concrete or masonry, protect against corrosion by painting contact surfaces with bituminous paint.
H. Set continuous sill members and flashing in full sealant bed, as specified in Section 079200 "Joint Sealants," to produce weathertight installation.
I. Install joint filler behind sealant as recommended by sealant manufacturer.
J. Install components plumb and true in alignment with established lines and grades.
2.3 INSTALLATION OF GLAZING
A. Install glazing as specified in Section 088000 "Glazing."
2.4 ERECTION TOLERANCES
A. Install aluminum-framed storefronts to comply with the following maximum tolerances:
1.Plumb: 1/8 inch in 10 feet; 1/4 inch in 40 feet.
2.Level: 1/8 inch in 20 feet; 1/4 inch in 40 feet.
3.Alignment:
a. Where surfaces abut in line or are separated by reveal or protruding element up to 1/2 inch wide, limit offset from true alignment to 1/16 inch.
b. Where surfaces are separated by reveal or protruding element from 1/2 to 1 inch wide, limit offset from true alignment to 1/8 inch.
c. Where surfaces are separated by reveal or protruding element of 1 inch wide or more, limit offset from true alignment to 1/4 inch.
4.Location: Limit variation from plane to 1/8 inch in 12 feet; 1/2 inch over total length.
2.5 FIELD QUALITY CONTROL
ALUMINUM-FRAMED STOREFRONTS 084313 - 8
A. Testing Agency: Engage a qualified testing agency to perform tests and inspections.
B. Field Quality-Control Testing: Perform the following test on representative areas of aluminum-framed storefronts.
1.Air Leakage: ASTM E783 at 1.5 times the rate specified for laboratory testing in "Performance Requirements" Article but not more than 0.09 cfm/sq. ft. at a static-air-pressure differential of 1.57 lbf/sq. ft..
a. Perform a minimum of two tests in areas as directed by Architect.
2.Water Penetration: ASTM E1105 at a minimum uniform static-air-pressure differential of 0.67 times the static-air-pressure differential specified for laboratory testing in "Performance Requirements" Article, but not less than 6.24 lbf/sq. ft., and shall not evidence water penetration.
C. Aluminum-framed storefronts will be considered defective if they do not pass tests and inspections.
D. Prepare test and inspection reports.
END OF SECTION 084313
ALUMINUM-FRAMED STOREFRONTS 084313 - 9
SECTION 085113 - ALUMINUM WINDOWS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes aluminum windows for exterior locations.
B. Related Requirements:
1.Section 084113 "Aluminum-Framed Entrances and Storefronts" for coordinating finish among aluminum fenestration units.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
1.Include construction details, material descriptions, glazing and fabrication methods, dimensions of individual components and profiles, hardware, and finishes for aluminum windows.
B. Shop Drawings: For aluminum windows.
1.Include plans, elevations, sections, hardware, accessories, insect screens, operational clearances, and details of installation, including anchor, flashing, and sealant installation.
C. Samples: For each exposed product and for each color specified, 2 by 4 inches in size.
D. Samples for Initial Selection: For units with factory-applied finishes.
1.Include Samples of hardware and accessories involving color selection.
1.3 INFORMATIONAL SUBMITTALS
A. Qualification Data: For manufacturer and Installer.
B. Product Test Reports: For each type of aluminum window, for tests performed by a qualified testing agency.
C. Sample Warranties: For manufacturer's warranties.
1.4 QUALITY ASSURANCE
A. Manufacturer Qualifications: A manufacturer capable of fabricating aluminum windows that meet or exceed performance requirements indicated and of documenting this performance by test reports and calculations.
B. Installer Qualifications: An installer acceptable to aluminum window manufacturer for installation of units required for this Project.
1.5 WARRANTY
A. Manufacturer's Warranty: Manufacturer agrees to repair or replace aluminum windows that fail in materials or workmanship within specified warranty period.
1.Failures include, but are not limited to, the following:
a. Failure to meet performance requirements.
ALUMINUM WINDOWS 085113 - 1
b. Structural failures including excessive deflection, water leakage, condensation, and air infiltration.
c. Faulty operation of movable sash and hardware.
d. Deterioration of materials and finishes beyond normal weathering.
e. Failure of insulating glass.
2.Warranty Period:
a. Window: 10 years from date of Substantial Completion.
b. Glazing Units: 10 years from date of Substantial Completion.
c. Aluminum Finish: 10 years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 SOURCE LIMITATIONS
A. Obtain aluminum windows from single source from single manufacturer.
B. MANUFACTURES
Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
Kawneer OptiQ AA 5450 Series Wausau Window and Wall Systems 3151 series
2.2 WINDOW PERFORMANCE REQUIREMENTS
A. Product Standard: Comply with
AAMA/WDMA/CSA 101/I.S.2/A440 for definitions and minimum standards of performance, materials, components, accessories, and fabrication unless more stringent requirements are indicated.
1.Window Certification: AAMA certified with label attached to each window.
B. Performance Class and Grade:
AAMA/WDMA/CSA 101/I.S.2/A440 as follows:
1.Minimum Performance Class: LC.
2.Minimum Performance Grade: 25.
C. Thermal Transmittance: NFRC 100 maximum whole-window U-factor of 0.30 Btu/sq. ft. x h x deg F.
D. Solar Heat-Gain Coefficient (SHGC): NFRC 200 maximum whole-window SHGC of 0.40.
E. Condensation-Resistance Factor (CRF): Provide aluminum windows tested for thermal performance according to AAMA 1503, showing a CRF of 52.
ALUMINUM WINDOWS 085113 - 2
F. Thermal Movements: Provide aluminum windows, including anchorage, that allow for thermal movements resulting from the following maximum change (range) in ambient and surface temperatures by preventing buckling, opening of joints, overstressing of components, failure of joint sealants, failure of connections, and other detrimental effects. Base engineering calculation on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss.
1.Temperature Change: 120 deg F ambient; 180 deg F material surfaces.
G. Sound Transmission Class (STC): Rated for not less than 30 STC when tested for laboratory sound transmission loss according to ASTM E90 and determined by ASTM E413.
H. Outside-Inside Transmission Class (OITC): Rated for not less than 30 OITC when tested for laboratory sound transmission loss according to ASTM E90 and determined by ASTM E1332.
I. Windborne-Debris Impact Resistance: Passes ASTM E1886 missile-impact and cyclic-pressure tests in accordance with ASTM E1996 for Wind Zone 3 for enhanced protection.
2.3 INSECT SCREENS
A. General: Fabricate insect screens to integrate with window frame. Provide screen for each operable exterior sash.
Screen wickets are not permitted.
1.Type and Location: Half, outside for single-hung sashes.
B. Aluminum Frames: Manufacturer's standard aluminum alloy complying with SMA 1004 or SMA 1201. Fabricate frames with mitered or coped joints or corner extrusions, concealed fasteners, and removable PVC spline/anchor concealing edge of frame.
1.Tubular Framing Sections and Cross Braces: Roll formed from aluminum sheet.
C. Aluminum Wire Fabric: 18-by-16 mesh of 0.011-inch-diameter, coated aluminum wire.
1.Wire-Fabric Finish: Natural bright.
2.4 FABRICATION
A. Fabricate aluminum windows in sizes indicated. Include a complete system for assembling components and anchoring windows.
B. Glaze aluminum windows in the factory.
C. Weather strip each operable sash to provide weathertight installation.
ALUMINUM WINDOWS 085113 - 3
D. Weep Holes: Provide weep holes and internal passages to conduct infiltrating water to exterior.
E. Complete fabrication, assembly, finishing, hardware application, and other work in the factory to greatest extent possible. Disassemble components only as necessary for shipment and installation.
2.5 GENERAL FINISH REQUIREMENTS
A. Comply with NAAMM's "Metal Finishes Manual" for recommendations for applying and designating finishes.
B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.
C. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.
2.6 ALUMINUM FINISHES
A. Finish designations prefixed by AA comply with the system established by the Aluminum Association for designating aluminum finishes.
B. Class I, Clear Anodic Finish: AA-M12C22A41 (Mechanical Finish: nonspecular as fabricated; Chemical Finish: etched, medium matte; Anodic Coating:
Architectural Class I, clear coating 0.018 mm or thicker) complying with AAMA 611.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine openings, substrates, structural support, anchorage, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.
B. Verify rough opening dimensions, levelness of sill plate, and operational clearances.
C. Examine wall flashings, vapor retarders, water and weather barriers, and other built-in components to ensure weathertight window installation.
D. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Comply with manufacturer's written instructions for installing windows, hardware, accessories, and other components. For installation procedures and requirements not addressed in manufacturer's written instructions, comply with installation requirements in ASTM E2112.
ALUMINUM WINDOWS 085113 - 4
B. Install windows level, plumb, square, true to line, without distortion or impeding thermal movement, anchored securely in place to structural support, and in proper relation to wall flashing and other adjacent construction to produce weathertight construction.
C. Install windows and components to drain condensation, water penetrating joints, and moisture migrating within windows to the exterior.
D. Separate aluminum and other corrodible surfaces from sources of corrosion or electrolytic action at points of contact with other materials.
3.3 ADJUSTING, CLEANING, AND PROTECTION
A. Adjust operating sashes and hardware for a tight fit at contact points and weather stripping for smooth operation and weathertight closure.
B. Clean exposed surfaces immediately after installing windows. Avoid damaging protective coatings and finishes.
Remove excess sealants, glazing materials, dirt, and other substances.
1.Keep protective films and coverings in place until final cleaning.
C. Remove and replace glass that has been broken, chipped, cracked, abraded, or damaged during construction period.
D. Protect window surfaces from contact with contaminating substances resulting from construction operations. If contaminating substances do contact window surfaces, remove contaminants immediately according to manufacturer's written instructions.
END OF SECTION 085113
ALUMINUM WINDOWS 085113 - 5
SECTION 08 71 00 - DOOR HARDWARE
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Finish Hardware for door openings, except as otherwise specified herein.
1. Door hardware for wood doors.
2. Keyed cylinders as indicated.
B. Related Sections:
1. Division 8: Hollow Metal Doors and Frames.
C. References: Comply with applicable requirements of the following standards. Where these standards conflict with other specific requirements, the most restrictive shall govern.
1. Builders Hardware Manufacturing Association (BHMA).
2. NFPA 101 Life Safety Code.
3. NFPA 80 Fire Doors and Windows.
4. ANSI-A156.xx Various Performance Standards for Finish Hardware.
5. UL10C Positive Pressure Fire Test of Door Assemblies.
6. ANSI-A117.1 Accessible and Usable Buildings and Facilities.
7. DHI /ANSI A115.IG Installation Guide for Doors and Hardware.
D. Intent of Hardware Groups:
1. Should items of hardware not definitely specified be required for completion of the Work, furnish such items of type and quality comparable to adjacent hardware and appropriate for service required.
2. Where items of hardware aren’t definitely or correctly specified, are required for completion of the Work, a written statement of such omission, error, or other discrepancy to the Contracting Officer, prior to date specified for receipt of bids for clarification by addendum; or, furnish such items in the type and quality established by this specification, and appropriate to the service intended.
1.2 SUBSTITUTIONS
A. Comply with Division 1.
DOOR HARDWARE 087100 - 1
1.3 SUBMITTALS
A. Comply with Division 1.
B. Special Submittal Requirements: Combine submittals of this Section with Sections listed below to ensure the "design intent" of the system/assembly is understood and can be reviewed together.
C. Product Data: Manufacturer's specifications and technical data including the following:
1. Detailed specification of construction and fabrication.
2. Manufacturer's installation instructions.
3. Wiring diagrams for each electric product specified. Coordinate voltage with electrical before submitting.
4. Submit 6 copies of catalog cuts with hardware schedule.
D. Shop Drawings - Hardware Schedule: Submit six complete reproducible copy of detailed hardware schedule in a vertical format.
1. List groups and suffixes in proper sequence.
2. Completely describe door and list architectural door number.
3. Manufacturer, product name, and catalog number.
4. Function, type, and style.
5. Size and finish of each item.
6. Mounting heights.
7. Explanation of abbreviations and symbols used within schedule.
E. Templates: Submit templates and "reviewed Hardware Schedule" to door and frame supplier and others as…