This document contains an existing residential compound single line diagram and details for a federal contract opportunity with the US Agency for International Development South Sudan. The opportunity is to provide electrical upgrade services for the USAID/South Sudan Juba Compound, including disconnecting and removing equipment and existing feeder segments from generators and main panelboards as well as loads. Phase One proposals are due from qualified organizations interested in upgrading the electrical infrastructure as depicted in the single line diagram detailing the current generator yards, automatic transfer switches, main panelboards, and distribution panels powering buildings within the residential compound.
View the file
Other files for this federal contract opportunity
Show all 50
USAID/South Sudan Juba Compound Electrical Upgrade has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERATOR YARD
G4
640kW/800kVA PRIME-
RATED, 1500RPM,
415Y/240V, 50 Hz
GENERATOR
P/BD 'GP1'
1200A
1200A
400kW/500kVA PRIME-
RATED, 1500RPM,
415Y/240V, 50 Hz
GENERATOR
800A
G3
ATS-1 - 1250A ,
415V, 4P, 50Hz
P/BD 'MDP1'
200A
G1
800A
800A
400kW/500kVA PRIME-
RATED, 1500RPM,
415Y/240V, 50 Hz
GENERATOR
800A
G2
ATS-2 - 1250A,
415V, 4P, 50Hz
GENERATOR ELECTRICAL BUILDING
125A125A125A
800A 800A
SPARESPARE
K K
K K
400kW/500kVA PRIME-
RATED, 1500RPM,
415Y/240V, 50 Hz
GENERATOR
1200AK
P/BD 'MDP1A'
225A200A125A1200A 200A125A125A
P/BD 'GP2'
P/BD 'MDP2'
125A 125A 125A
800A1200A
SPARE SPARE
KK1200AK
P/BD 'MDP2A'
125A 225A 125A225A 200A 225A 300A
P/BD 'GP3'
1200AK 1200AK1200A1200A
SPARE SPARE
KK
K
N.O. N.O.N.C. N.C.
N.C.
SD
P1
(G
EN
. B
LD
G
PA
N
EL
BO
AR
D
P/
BD
'I T'
(IT
H
O U
SE
P/
BD
'G B1
(N
O R
TH
C
AC
PN
L
D
IS
T.
P /B
D (A
LA
M
O V
IL
LA
G E)
P/
BD
'H S5
H O
U
SE
P/
BD
'L S'
(L O
C
AL
S
TA
FF
LI
FT
ST
AT
IO
N
P/
BD
'4 0'
(B
LD
G
0)
P/
BD
'K P'
(O
LD
K
IT
C H
EN
W
AS
TE
W
AT
ER
TR
EA
TM
EN
T
PL
AN
T
P/
BD
'2 1'
(T O
W N
H O
U
SE
P/
BD
'2 0'
(T O
W N
H O
U
SE
P/
BD
'2 2'
(T O
W N
H O
U
SE
P/
BD
'G
YM
(G
YM
B
LD
G
BS
H
(B
LU
E
SA
FE
H
AV
EN
O
SH
(O R
AN
G
E
SA
FE
H
AV
EN
TE
M
P.
G
EN
TE
C
H . H
O U
SE
P/
BD
'M D
P-
(P
ER
IM
ET
ER
W
AL
L)
P/
BD
D P2
(B
LD
G
6)
C H
D
P C
O U
R
TH
O U
SE
D
IS
T.
P
AN
EL
(T O
W N
H O
U
SE
1 DISCONNECT AND REMOVE EQUIPMENT AND EXISTING FEEDER SEGMENTS FROM GENERATORS
THROUGH MPD1, MDP1A, MDP2, MDP2A AS WELL AS THOSE BETWEEN MDP1, MDP1A, MDP2, MDP2A AND
THEIR LOADS
PLAN REFERENCE NOTES
125A
P/
BD
'2
(B
LD
G . 2
5)
E1-702
0.039:1
PDM
WFS
049901E1-702.DWG
EXISTING RESIDENTIAL COMPOUND
SINGLE LINE DIAGRAM
A
B
C
1 2 3
D
E
F
G
H
4 5 6 7 98 10
I
J
K
L
M
N
O
P
1 2 3 4 5 6 7 98 10
11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
11 12 13 14 15 16 17
I
J
K
L
M
N
O
P
UNCLASSIFIED
UNCLASSIFIED
As Indicated
WARNING: This document is the property of the U.S. Government. Further reproduction and/or distribution outside the contractor team is prohibited without the express written approval of USAID.
CADD Plot Scale
Drawing Scale
USAID/PE/PBD
OBO Project Number
CADD File Name
USAID/PE/PM
Drawing Title
Release For Construction:
Drawn By
Checked By
Project Number
Classification
Date NumberSheet
0499.01
JULY 13, 2020
COMPOUND ELECTRICAL
UPGRADE
Juba, South Sudan
Revision Schedule
Rev Number Description Date
UNCLASSIFIED
ISSUE FOR BID
BRIDGING DOCUMENTS
Bridging
ISSUE FOR BID100% 100% BACK-CK
1 ADDENDUM 1 09/27/2021
EXISTING RESIDENTIAL COMPOUND SINGLE LINE DIAGRAM
SCALE: NONE
E1-702
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text