This document is an amendment to a solicitation for renovating elevators in Building 200, specifically detailing elevator cab finishes and lighting changes for passenger and service elevators. The amendment covers detailed specifications for elevator interiors, including changes to center panel materials (from EP-4 stainless steel to EP-3 fused nickel silver for passenger elevators), handrail specifications (HR-10 1.5" round stainless steel for passenger elevators and BR-10 3" x ¼" flat stainless steel for service elevators), and ceiling configurations. For passenger elevators (P-1 through P-5) and most service elevators (S-6, S-7), the specification mandates Forms & Surfaces 6-Panel stainless steel ceiling with satin finish, six downlights, and perimeter accent lighting. Service elevator S-8 will maintain its existing top of elevator car configuration with wall-mounted lights, which will be refurbished with new translucent panels and re-lamped to LED.
View the file
Other files
Show 40 more
Latest 50 of 73 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Elevator cab finishes and lighting changes:
Sheet AI201
a. Detail 1/AI201: Cab Interiors – Passenger
i. ELEVATIONS - Center panel directly behind the handrails on both side elevations and the back elevation shall be “EP-3 FUSED NICKEL SILVER” ilo
“EP-4 STAINLESS STEEL”.
ii. CEILING PLAN – All ceilings in passenger elevators (P-1, P-2, P-3, P-4, P-5) shall be Forms & Surfaces 6-Panel stainless steel ceiling, satin finish with six
(6) downlights and perimeter accent lighting.
b. Detail 2/AI202: Cab Interiors – Service
i. ELEVATIONS – All handrails in service elevators (S-6, S-7, S-8) on both side elevations and the back elevation shall be “BR-10 BUMPRAIL” ilo “HR-10
HANDRAIL”.
i. CEILING PLAN – Ceilings in service elevators (S-6, S-7) shall be Forms & Surfaces 6-Panel stainless steel ceiling, satin finish with six (6) downlights and perimeter accent lighting.
ii. CEILING PLAN – No ceiling to be provided in service elevator (S-8). The existing top of elevator car configuration with extended doghouse and wall mounted lights on the side elevations to be maintained. The top of wall light fixtures shall be refurbished with new translucent panel and shall be re-lamped to LED.
Sheet AI202
a. Finish Schedule
i. All passenger elevator handrails shall be “HR-10”, 1.5” round stainless steel with radiused end returns.
ii. All service elevator handrails shall be “BR-10”, 3” x ¼” flat stainless steel with radiused end returns.
Specification Section 14 21 10:
a. Paragraph 2.44 – Car Enclosure: Alternate #4, New Passenger/Service Elevators:
i. Replace Paragraph J.1 for the following:
1. For all passenger elevators (P-1, P-2, P-3, P-4, P-5) and service elevators (S-6, S-7) the ceiling system & lighting shall be “Forms & Surfaces” 6-Panel stainless steel ceiling, satin finish with six (6) downlights and perimeter accent lighting.
ii. Delete the following from Paragraph J.2:
Solicitation 36C25225R0036 Project 578-25-003 Renovate Elevators in Bldg 200 Amendment P0006 - Attachment 01 Page 1 of 2
1. Provide LED illuminated car light fixtures above the ceiling panels.
b. Paragraph 2.44.K Optional lighting for service elevators – Clarification:
i. This section shall apply to service elevator S-8 only.
Solicitation 36C25225R0036 Project 578-25-003 Renovate Elevators in Bldg 200 Amendment P0006 - Attachment 12a