BLDG200F2R2010.xls
XLS spreadsheet 375 KB Posted
- Attached to
- Z1DA--578-25-003 Renovate Elevators B200 (Construction) at the Hines VA Hospital in Hines, IL
- Solicitation number
- 36C25225R0036_3
About this file
The file BLDG200F2R2010.xls is a comprehensive asbestos assessment document detailing material conditions across multiple rooms in a building, specifically documenting Building 200's 2nd floor. The spreadsheet systematically catalogs various building materials, their locations, sample identification numbers, and asbestos presence/condition, with rooms ranging from A201 to D203.
The assessment identifies multiple material types including wall-board (WALL-BRD), plaster (PLAS-A/PLAS-W), miscellaneous materials (MSTC), vinyl floor tiles (VFT), acoustic tiles (ACT), baseboards (BSBRD), and pipe fittings across different room sections. Most materials are classified as having "GOOD" condition with "LOW" potential risk, with many entries noting "ASSUME POSITIVE" for potential asbestos presence, particularly behind walls and above ceilings. The document appears related to a VA Hospital renovation project (Solicitation Number 36C25225R0036_3) for elevator renovations in Building 200 at the Hines VA Hospital in Hines, IL, suggesting this material assessment is preparatory to potential construction or renovation work.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLDG 200 2ND FL
| LOCATION | ACM % | TYPE | QTY | SAMPLE | MATERIAL DESCRIPTION | REEVALUATION 2010 | COMMENTS | Abated | Date | Work Order | Project No. | Report | Point of Contact | Notes | |||
| RANK | FUNCTION | FRIABLE | COND | POT FOR | |||||||||||||
| Y/N | DIST | ||||||||||||||||
| AREA 2ND FLOOR | |||||||||||||||||
| ROOM 228 | |||||||||||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| ROOM 230C | |||||||||||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| ROOM 235 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A201 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 75 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 320 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A202 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| PLAS-A | 0 | N/A | 140 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 384 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A203 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| MSTC | 0 | N/A | 160 SF | 97867-X | MSTC FOR 97867 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 168 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 416 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 18 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM A204 | |||||||||||||||||
| MSTC | 0 | N/A | 360 SF | 97867-X | MSTC FOR 97867 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 97924-X | MSTC FOR 97924 LAB RESULTS | N | GOOD | LOW | NO CHANGE | |||||||||
| MSTC | 0 | N/A | 31 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM A205 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| PLAS-A | 0 | N/A | 204 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 464 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A206 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| MSTC | 0 | N/A | 880 SF | 97867-X | MSTC FOR 97867 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 180 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 432 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 72 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM A207 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| MSTC | 0 | N/A | 160 SF | 97867-X | MSTC FOR 97867 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 169 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 416 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 18 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM A208 | |||||||||||||||||
| 7 | VFT | 5 | CHR | 120 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 120 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| ACT | 0 | N/A | 100 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| ROOM A209 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 7 | VFT | 5 | CHR | 110 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 110 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| ACT | 0 | N/A | 110 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 14 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 14 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM A210 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | REMOVED | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | N/A | N/A | N/A | 97884-X | 2'X4' HILLS W/PNHL | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97900-X | 2'X4' POCK MARK | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A211 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A212 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97900-X | 2'X4' POCK MARK | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A212A | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A214 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 992 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | 0 | N/A | 880 SF | 97884-X | 2'X4' HILLS W/PNHL | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 5 | CHR | 880 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 880 SF | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| 5 | PLAS-W | 3 | CHR | 62 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| BSBRD | 0 | N/A | 41 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 41 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A215 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| ROOM A216 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97900-X | 2'X4' POCK MARK | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A217 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | N/A | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | N/A | N/A | N/A | N/A | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | N/A | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | N/A | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | N/A | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| BSBRD | N/A | N/A | N/A | N/A | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | N/A | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A218 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 97867-X | MSTC FOR 97867 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| VFT | N/A | N/A | N/A | 97867-X | 1'X1' WHT W/BRN & GRY STRKS | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | N/A | N/A | N/A | 97884-X | 2'X4' HILLS W/PNHL | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A218A | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A218B | |||||||||||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A219 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97900-X | 2'X4' POCK MARK | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A220 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PHNL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A221 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A222 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PHNL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A223 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A223A | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A223B | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 6 | PIPE F-DHW | N/A | N/A | N/A | 97885-X | HW FITG | N/A | N/A | N/A | ABATED | |||||||
| 6 | PIPE F-DCW | N/A | N/A | N/A | 97886-X | CW FITG | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A224 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PHNL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A225 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A226 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| VFT | N/A | N/A | N/A | 97855-X | GRY SHEET | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 97855-X | MSTC FOR 97855 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A227 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| ROOM A227A | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| ROOM A227B | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| ROOM A228B | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| ROOM A229 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| ROOM A229 | |||||||||||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4'' BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A230 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A231 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A232 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A233 | |||||||||||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABAATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABAATED | |||||||
| ROOM A234 | |||||||||||||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9X9 TAN W/BRN WHT STRK 97889 | N/A | N/A | N/A | ABAATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PHNL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | N/A | N/A | N/A | 97900-X | 2'X4' POCK MARK | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABAATED | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABAATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A236 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABAATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABAATED | |||||||
| 7 | VFT | N/A | N/A | N/A | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N/A | N/A | N/A | ABAATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97890-X | MSTC FOR 97889 | N/A | N/A | N/A | ABAATED | |||||||
| ACT | N/A | N/A | N/A | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABAATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM A237 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | VFT | 5 | CHR | 440 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM A238 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| ROOM A239 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| ROOM A240 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | NO CHANGE | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 6 | FIRESTOP | 10 | CHR | 97509-X | FIRESTOP WHT | Y | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 1168 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 1150 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A240A | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 140 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 384 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A240B | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| ROOM A240B | |||||||||||||||||
| PLAS-W | 0 | N/A | 256 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 60 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A240C | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 90 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 304 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A240D | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 6 | PIPE F-DHW | 15 | CHR | 97755-X | HW FITG | Y | GOOD | LOW | NO CHANGE | ||||||||
| 6 | PIPE F-DCW | 15 | CHR | 97756-X | CW FITG | Y | GOOD | LOW | NO CHANGE | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 680 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A241 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 720 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ACT | 0 | N/A | 450 SF | 97884-X | 2'X4' HILLS W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 5 | CHR | 450 SF | 97889-X | 9"X9" TAN W/LRG SRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 450 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| BSBRD | 0 | N/A | 30 SF | 97891-X | 4" CRM BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 30 SF | 97892-X | MSTC FOR 97891 | N | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 45 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| ROOM A242 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 100 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 6 | FIRESTOP | 10 | CHR | 97509-X | FIRESTOP WHT | Y | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 5 | CHR | 100 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 100 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| ACT | 0 | N/A | 100 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 13 SF | 98265-X | MSTC FOR 98265 LAB RESLUT | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 13 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM A243 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 7 | VFT | 5 | CHR | 110 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 110 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| ACT | 0 | N/A | 110 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 14 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 14 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM A244 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 48 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 224 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A245 | |||||||||||||||||
| ACT | 0 | N/A | 160 SF | 97884-X | 2'X4' HILLS W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 5 | CHR | 160 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 160 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| BSBRD | 0 | N/A | 18 SF | 97891-X | 4" CRM BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 18 SF | 97892-X | MSTC FOR 97891 | N | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 448 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM A246 | |||||||||||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| ROOM A202 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| ACT | 0 | N/A | 880 SF | 97884-X | 2'X4' HILLS W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 48 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 224 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM B203 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| PLAS-A | 0 | N/A | 48 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 224 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM B204 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 7 | VFT | 5 | CHR | 100 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 100 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| ACT | 0 | N/A | 100 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 13 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 13 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM B205 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 352 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 7 | MSTC | 30 | CHR | 160 SF | 97890-X | MSTC FOR 97899 | N | GOOD | LOW | NO CHANGE | |||||||
| ACT | 0 | N/A | 120 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 22 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 15 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 15 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 8 | CHR | 84 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 84 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B206 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 384 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ACT | 0 | N/A | 140 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 24 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 16 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 16 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 8 | CHR | 140 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 140 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B207 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 368 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ACT | 0 | N/A | 126 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 23 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 15 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 15 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 8 | CHR | 126 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 126 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B208 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 304 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ACT | 0 | N/A | 90 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 19 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 13 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 13 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 8 | CHR | CHR | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 90 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B209 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 7 | VFT | 5 | CHR | 100 SF | 97889-X | 9"X9" TAN W/LRG BRN & WHT STRK | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 100 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| ACT | 0 | N/A | 100 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| BSBRD | 0 | N/A | 13 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 13 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| PLAS-W | 0 | N/A | 320 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| PLAS-A | 0 | N/A | 60 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM B212 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 1920 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 6 | FIRESTOP | 10 | CHR | 97509-X | FIRESTOP WHT | Y | GOOD | LOW | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | Presume behind walls & above ceilings | ||||||||
| ACT | 0 | N/A | 2920 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| ACT | 0 | N/A | 280 SF | 97873-X | 1'X1' WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 79 SF | 97875-X | 6" BRN BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 79 SF | 97875-X | MSTC FOR 97875 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 120 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| BSBRD | 0 | N/A | 16 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 5 | CHR | 3200 SF | 97437- | 1'X1' WHT W/BLK & GRY MOT | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 20 | CHR | 3200 SF | 97438- | MSTC FOR 97437 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B212A | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | NO CHANGE | ||||||||
| WALL-BRD | 0 | N/A | 480 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ACT | 0 | N/A | 200 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| ACT | 0 | N/A | 200 SF | 97873-X | 1'X1' WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| 7 | MSTC | 30 | CHR | 100 SF | 97890-X | MSTC FOR 97889 | N | GOOD | LOW | NO CHANGE | |||||||
| 5 | PLAS-W | 3 | CHR | 30 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 20 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 20 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM B212B | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| WALL-BRD | 0 | N/A | 320 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ACT | 0 | N/A | 100 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 13 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 13 SF | 98265-X | 4" ELK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM B212C | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| WALL-BRD | 0 | N/A | 480 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ACT | 0 | N/A | 200 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 30 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 20 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 20 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM B212D | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| ACT | 0 | N/A | 90 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 304 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 13 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 13 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| ROOM B213 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | NO CHANGE | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | NO CHANGE | ||||||||
| 6 | FIRESTOP | 10 | CHR | 97509-X | FIRESTOP WHT | Y | GOOD | LOW | NO CHANGE | ||||||||
| PIPE F-STM | 0 | N/A | 30 LF | 97752-X | HP STM FITG | Y | GOOD | LOW | NO CHANGE | ||||||||
| 6 | PIPE F-CON | 15 | CHR | 10 LF | 97753-X | COND FITG | Y | GOOD | LOW | NO CHANGE | |||||||
| 6 | PIPE F-CHW | 5 | MIX | 75 LF | 97432- | CHILL FIT | Y | GOOD | LOW | NO CHANGE | |||||||
| 6 | PIPE F-CHW | 5 | CHR | 97433- | CHILL RET FIT | Y | GOOD | LOW | NO CHANGE | ||||||||
| 6 | PIPE F-STM | 3 | CHR | 20 LF | 97434- | STM FITG | Y | GOOD | LOW | NO CHANGE | |||||||
| 7 | VIB | 80 | CHR | 97435- | VIB WHT | N | GOOD | LOW | NO CHANGE | ||||||||
| 1 | DEBRIS | 20 | CHR | 97436- | DEBRIS | Y | GOOD | LOW | NO CHANGE | ||||||||
| ROOM B216 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 352 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| ACT | 0 | N/A | 120 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 22 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| BSBRD | 0 | N/A | 15 SF | 98265-X | 4" BRN BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 15 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 8 | CHR | 120 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 120 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B217 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | NO CHANGE | ||||||||
| WALL-BRD | 0 | N/A | 352 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 22 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| MSTC | 0 | N/A | 15 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 15 SF | 98265-X | 4" BRN BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 8 | CHR | 120 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 120 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B218 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | NO CHANGE | ||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 25 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| PLAS-A | 0 | N/A | 150 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| ROOM B219 | |||||||||||||||||
| BSBRD | 0 | N/A | 40 SF | 97891-X | 4" CRM BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 40 SF | 97892-X | MSTC FOR 97891 | N | GOOD | LOW | NO CHANGE | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | Y | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 992 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B220 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| ROOM B221 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | N/A | N/A | N/A | 97900-X | 2'X4' POCK MARK | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B222 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | N/A | N/A | N/A | 97883-X | 2'X4' SMOOTH RNDM PNHL | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B223 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| VFT | N/A | N/A | N/A | 97867-X | 1'X1' WHT W/BRN & GRY STRKS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 97867-X | MSTC FOR 97867 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | N/A | N/A | N/A | 97884-X | 2'X4' HILLS W/PNHL | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BRN BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM B223A | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BRN BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B223B | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM B224 | |||||||||||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | |||||||
| ACT | N/A | N/A | N/A | 97900-X | 2'X4' POCK MARK | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-W | N/A | N/A | N/A | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | N/A | N/A | N/A | 98265-X | 4" BRN BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | N/A | N/A | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | N/A | N/A | N/A | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | N/A | N/A | N/A | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B225 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | NO CHANGE | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | NO CHANGE | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | Y | N/A | LOW | NO CHANGE | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | Y | GOOD | LOW | NO CHANGE | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | NO CHANGE | |||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BRN BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | NO CHANGE | |||||||
| 7 | MSTC | 30 | CUR | 440 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | NO CHANGE | |||||||
| ROOM B226 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 512 SF | 97441-X | WALL-BRD | Y | GOOD | MOD | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | ABATED | |||||||
| 5 | PLAS-W | 3 | CHR | 32 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | ABATED | |||||||
| PLAS-A | 0 | N/A | 240 SF | 98261-X | PLAS | Y | GOOD | MOD | REMOVED | ||||||||
| BSBRD | 0 | N/A | 21 SF | 98265-X | 4" BRN BSBRD | N | GOOD | LOW | REMOVED | ||||||||
| MSTC | 0 | N/A | 21 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 120 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 120 SF | 98279-X | MSTC FOR 98278 | N | GOOD | LOW | ABATED | |||||||
| ROOM B227 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| PLAS-A | 0 | N/A | 200 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-W | 0 | N/A | 592 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM B228 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | ||||||||||||
| ROOM B228 | |||||||||||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BRN BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B229 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | REMOVED | |||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BRN BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B230 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 256 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | 0 | N/A | 60 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM B233 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| ROOM 8234 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | REMOVED | |||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B235 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B236 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 928 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| PLAS-A | 0 | N/A | 384 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM B237 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B238 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 176 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | 0 | N/A | 120 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 11 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | 0 | N/A | 176 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 15 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 15 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 120 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 120 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B238B | |||||||||||||||||
| WALL-BRD | 0 | N/A | 224 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | 0 | N/A | 40 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 14 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| BSBRD | 0 | N/A | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | |||||||||
| ROOM B238B | |||||||||||||||||
| MSTC | 0 | N/A | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | |||||||||
| 7 | VFT | 8 | CHR | 40 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 40 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B239 | |||||||||||||||||
| ACT | 0 | N/A | 120 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 11 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | 0 | N/A | 176 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 15 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 15 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 120 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 120 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| WALL-BRD | 0 | 176 SF | 97441- | WALL-BRD | N/A | N/A | N/A | REMOVED | |||||||||
| ROOM B239A | |||||||||||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| PLAS-W | 0 | N/A | 240 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | 0 | N/A | 176 SF | 97884-X | 2'X4' HILLS W/PNHL | N/A | N/A | N/A | REMOVED | ||||||||
| ROOM B240 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B241 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 320 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| ACT | 0 | N/A | 100 SF | 97900-X | 2'X4' POCK MARK | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| BSBRD | 0 | N/A | 13 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 13 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 100 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 100 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B242 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 336 SF | 97441-X | WALL-BRD | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97755-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| 7 | PIPE F-DCW | 15 | CHR | 97765-X | N-ACC ASSUME POSITIVE | N/A | N/A | N/A | ABATED | ||||||||
| ACT | 0 | N/A | 440 SF | 97899-X | 2'X4' PNHL W/BUBBLES | N/A | N/A | N/A | REMOVED | ||||||||
| 5 | PLAS-W | 3 | CHR | 21 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ABATED | |||||||
| PLAS-W | 0 | N/A | 336 SF | 98261-X | PLAS | N/A | N/A | N/A | REMOVED | ||||||||
| BSBRD | 0 | N/A | 28 SF | 98265-X | 4" BLK BSBRD | N/A | N/A | N/A | REMOVED | ||||||||
| MSTC | 0 | N/A | 28 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N/A | N/A | N/A | REMOVED | ||||||||
| 7 | VFT | 8 | CHR | 440 SF | 98278-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ABATED | |||||||
| 7 | MSTC | 30 | CHR | 440 SF | 98279-X | MSTC FOR 98278 | N/A | N/A | N/A | ABATED | |||||||
| ROOM B246 | |||||||||||||||||
| ACT | 0 | N/A | 110 SF | 97900-X | 2'X4' POCK MARK | Y | GOOD | LOW | NO CHANGE | ||||||||
| ACT | 0 | N/A | 800 SF | 97884-X | 2'X4' HILLS W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| ACT | 0 | N/A | 1040 SF | 97884-X | 2'X4' HILLS W/PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| ROOM C201 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | NO CHANGE | ||||||||
| PIPE F-STM | 0 | N/A | 97752-X | HP STM FITG | Y | GOOD | LOW | NO CHANGE | |||||||||
| 6 | PIPE F-CON | 15 | CHR | 97753-X | COND FITG | Y | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 420 SF | 97867-X | MSTC FOR 97867 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| VFT | 0 | N/A | 420 SF | 97867-X | 1'X1' WHT W/BRN & GRY STRKS | N | GOOD | LOW | NO CHANGE | ||||||||
| PLAS-W | 0 | N/A | 752 SF | 98261-X | PLAS | Y | GOOD | MOD | NO CHANGE | ||||||||
| BSBRD | 0 | N/A | 31 SF | 98265-X | 4" BLK BSBRD | N | GOOD | LOW | NO CHANGE | ||||||||
| MSTC | 0 | N/A | 31 SF | 98265-X | MSTC FOR 98265 LAB RESULTS | N | GOOD | LOW | NO CHANGE | ||||||||
| PIPE F-CHW | 0 | N/A | 97882- | CHILL RET FITG | Y | GOOD | LOW | NO CHANGE | |||||||||
| ACT | 0 | N/A | 210 SF | 97883- | 2'X4' SMOOTH RNDM PNHL | Y | GOOD | LOW | NO CHANGE | ||||||||
| ACT | 0 | N/A | 97884- | 2'X4' HILLS W/PNHL | Y | GOOD | LOW | NO CHANGE |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .