BLDG200 F10R2010.xls
XLS spreadsheet 197 KB Posted
- Attached to
- Z1DA--578-25-003 Renovate Elevators B200 (Construction) at the Hines VA Hospital in Hines, IL
- Solicitation number
- 36C25225R0036_3
About this file
This Excel file (BLDG200 F10R2010.xls) appears to be an asbestos and building material inventory document for Building 200, specifically documenting the 10th floor. The spreadsheet provides a detailed room-by-room breakdown of various building materials, their locations, quantities, and potential asbestos-containing material (ACM) characteristics. Each room entry includes specifics such as baseboard (BSBRD), mastic (MSTC), vinyl floor tile (VFT), wall board, plaster, and other building components, with notations about material condition, potential friability, and assessment status.
The inventory includes comprehensive data for multiple rooms (Room 1000 through Room C111), tracking material types like 9"x9" tan floor tiles, 4" black baseboards, wall boards, and various pipe fittings. Most entries are marked with condition assessments such as "GOOD" and risk levels like "LOW", with some materials noted as "N/A" or "No Change". Several rooms show partial or complete material abatement, suggesting ongoing renovation or maintenance work. While the document does not directly relate to the associated federal contract opportunity for elevator renovation at Hines VA Hospital, it provides a detailed material condition assessment that could be relevant to broader building maintenance and renovation planning.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLDG 200 10TH FL
| LOCATION | ACM % | TYPE | QTY | SAMPLE | MATERIAL DESCRIPTION | REEVALUATION 2010 | COMMENTS | Abated | Date | Work Order | Project No. | Report | Point of Contact | Notes | |||
| RANK | FUNCTION | FRIABLE | COND | POT FOR | |||||||||||||
| Y/N | DIST | ||||||||||||||||
| AREA 10TH FLOOR | |||||||||||||||||
| ROOM 1000 | Room # Not Observed | ||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| BSBRD | 0 | 15 SF | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | ||||||||||
| MSTC | 0 | 15 SF | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | ||||||||||
| 7 | VFT | 3 | CHR | 375 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 375 SF | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | ||||||||
| PLAS-W | 0 | 600 SF | 97543-X | PLAS | N/A | N/A | N/A | ||||||||||
| ACT | 0 | 375 SF | 97865-X | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | ||||||||||
| ROOM 1000A | Room # Not Observed | ||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| BSBRD | 0 | N/A | 23 SF | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| MSTC | 0 | N/A | 23 SF | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 630 SF | 97548-X | ELV PLAS | N/A | N/A | N/A | |||||||||
| ACT | 0 | N/A | 250 SF | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-STM | 2 | AM | 97534- | STM FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-CON | 2 | AM | 97535- | COND FITG | N/A | N/A | N/A | |||||||||
| 7 | VFT | 3 | CHR | 375 SF | 97536- | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 375 SF | 97537- | MSTC FOR 97536 | N/A | N/A | N/A | ||||||||
| ROOM 1000B | Room # Not Observed | ||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-STM | 2 | AM | 97534-X | STM FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-CON | 2 | AM | 97535-X | COND FITG | N/A | N/A | N/A | |||||||||
| ROOM 1001 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 23 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 23 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 792 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 484 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1002 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 144 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1003 | Room # Not Observed | ||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 144 SF | 97543-X | PLAS | N/A | N/A | N/A | |||||||||
| 5 | PLAS-W | 3 | CHR | 15 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ||||||||
| ROOM 1004 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 29 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | VFT | 3 | CHR | 440 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 792 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 484 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1005 (Toilet) | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1005A | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1005B | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1006 (Toilet) | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 252 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97865-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1007 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 15 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 100 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 100 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 252 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 100 SF | 97865-X | 2'X4' THN WRM W/PHNL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1008 | Room # Not Observed | ||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97543-X | PLAS | N/A | N/A | N/A | |||||||||
| PLAS-A | 0 | N/A | 28 SF | 97543-X | PLAS | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | N/A | N/A | N/A | |||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | |||||||||
| ROOM 1009 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 252 SF | 97541-X | WALL BOARD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97865-X | 2'X4' THN WRM W/PHNL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL BOARD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1010 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CUR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 300 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97865-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1011 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1012 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97865-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1013 | 1013 | ||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 54 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 270 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1014 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1015 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 17 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 17 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 468 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 187 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1016 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 378 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1017 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1018 | |||||||||||||||||
| BSBRD | 0 | N/A | 29 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 29 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | 792 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | |||||||||
| ACT | 0 | 484 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | |||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1019 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 144 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1020 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 323 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 144 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1021 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 29 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 792 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | 484 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | |||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1022 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 29 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 264 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 264 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 264 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 468 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 630 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1023 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1024 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 48 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | 20 | CHR | 48 SF | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| PLAS-W | 0 | N/A | 234 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 42 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1025 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 15 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 15 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 112 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 112 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 112 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 396 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1026 (1) | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 20 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 20 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 238 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 238 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| PLAS-W | 0 | N/A | 360 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1027 (2) | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 20 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 20 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 238 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 238 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 91 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 360 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1028 (3) | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 20 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 20 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 238 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 238 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 91 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 360 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1029 (4) | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 20 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 20 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 238 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 238 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 91 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 360 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1029A | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 10 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 10 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 50 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| MSTC | 20 | CHR | 50 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 50 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 200 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1030 | |||||||||||||||||
| BSBRD | 0 | N/A | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | Removed | |||||||||
| MSTC | 0 | N/A | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | Removed | |||||||||
| VFT | 0 | N/A | 49 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | Removed | ||||||||
| 7 | MSTC | 20 | CHR | 49 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | Abated | |||||||
| ACT | 0 | N/A | 49 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 150 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1031A | |||||||||||||||||
| BSBRD | 0 | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Room # Not Observed | |||||||||
| MSTC | 0 | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | ||||||||||
| VFT | 0 | N/A | 25 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N/A | N/A | N/A | |||||||||
| 7 | MSTC | 20 | CHR | 25 SF | 97539-X | MSTC FOR 97538 | N/A | N/A | N/A | ||||||||
| ACT | 0 | N/A | 25 SF | 97540-X | 2'X4' POCK MARK | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 180 SF | 97541-X | WALL-BRD | N/A | N/A | N/A | |||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | |||||||||
| ROOM 1032 (5) | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 204 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | MOD | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 204 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 204 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 522 SF | 97543-X | PLAS | Y | GOOD | MOD | |||||||||
| ROOM 1033 (6) | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 204 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 204 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 204 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 522 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1034 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 17 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 17 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 323 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 153 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 468 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1035 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 18 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 504 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1036 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 28 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1037 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 18 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 504 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1038 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 18 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| PLAS-W | 0 | N/A | 504 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97865-X | 2'X41 THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1039 | Room # Not Observed | ||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| 7 | VFT | 3 | CHR | 48 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 48 SF | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | ||||||||
| PLAS-A | 0 | N/A | 28 SF | 97543-X | PLAS | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 180 SF | 97543-X | PLAS | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | N/A | N/A | N/A | |||||||||
| ROOM 1040 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 18 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 100 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 100 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| PLAS-W | 0 | N/A | 504 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1041 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 18 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 504 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 192 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1042 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 270 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1043 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97334-X | 4" BULK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 29 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | N/A | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | N/A | 440 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | N/A | 440 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 792 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | N/A | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | N/A | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 484 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | N/A | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1044 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 144 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1045 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 144 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1046 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 29 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | N/A | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | N/A | 440 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | N/A | 440 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 792 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | N/A | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | N/A | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 484 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | N/A | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 104 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 29 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 792 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 484 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1048 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 144 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1049 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 15 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 144 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1050 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 29 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 792 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 484 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1051 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 15 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 15 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 414 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 132 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 5 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1052 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 16 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 16 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 5 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 5 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 432 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 143 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 5 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1054 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 5 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 5 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | N/A | 360 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | |||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | N/A | 99 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | |||||||||
| 5 | PLAS-W | 5 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1055 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 5 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Abated | |||||||
| 7 | MSTC | 5 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | Abated | |||||||
| WALL-BRD | N/A | 360 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | |||||||||
| ACT | N/A | 100 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | |||||||||
| 5 | PLAS-W | 5 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | Abated | ||||||||
| ROOM 1056 | |||||||||||||||||
| 7 | VFT | 5 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 5 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | N/A | 504 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | |||||||||
| ACT | N/A | 143 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | |||||||||
| 5 | PLAS-W | 5 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1057 | |||||||||||||||||
| 7 | VFT | 5 | CHR | 48 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 5 | CHR | 48 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | N/A | 288 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | |||||||||
| ACT | N/A | 64 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | |||||||||
| 5 | PLAS-W | 5 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1058 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 5 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Abated | |||||||
| 7 | MSTC | 5 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | Abated | |||||||
| WALL-BRD | N/A | 378 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | |||||||||
| ACT | N/A | 121 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | |||||||||
| 5 | PLAS-W | 5 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | Abated | ||||||||
| ROOM 1059 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1060 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1061 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 216 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 35 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1062 (JC) | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1063 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 198 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 30 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1064 | Room # Not Observed | ||||||||||||||||
| BSBRD | 0 | N/A | 25 SF | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| MSTC | 0 | N/A | 25 SF | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | |||||||||
| 7 | PIPE-DRN | 10 | CHR | 97524-X | DRAIN FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DCW | 20 | N/A | 97525-X | ICE WATER FITG | N/A | N/A | N/A | |||||||||
| 7 | VFT | 3 | CHR | 425 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 425 SF | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | ||||||||
| WALL-BRD | 0 | N/A | 684 SF | 97541-X | WALL-BRD | N/A | N/A | N/A | |||||||||
| ACT | 0 | N/A | 357 SF | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | |||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | |||||||||
| ROOM 1065 | Room # Not Observed | ||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| BSBRD | 0 | N/A | 15 SF | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| MSTC | 0 | N/A | 15 SF | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | |||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | ||||||||
| WALL-BRD | 0 | N/A | 414 SF | 97541-X | WALL-BRD | N/A | N/A | N/A | |||||||||
| ACT | 0 | N/A | 132 SF | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | |||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | |||||||||
| ROOM 1066 | Room # Not Observed | ||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| ROOM 1067 | Room # Not Observed | ||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| ROOM 1068 | Room # Not Observed | ||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-STM | 2 | CHR | 97534-X | STM FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-CON | 2 | CHR | 97535-X | COND FITG | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 738 SF | 97543-X | PLAS | N/A | N/A | N/A | |||||||||
| PLAS-A | 0 | N/A | 330 SF | 97543-X | PLAS | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | N/A | N/A | N/A | |||||||||
| ROOM 1069A | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| VFT | 0 | N/A | 168 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 168 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 168 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 150 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1069A | |||||||||||||||||
| BSBRD | 0 | N/A | 11 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 11 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| VFT | 0 | N/A | 70 SF | 97538- | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 70 SF | 97539- | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 70 SF | 97540- | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 306 SF | 97541- | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PLAS-W | 1 | CHR | 97542- | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1070 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 14 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 14 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 104 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 104 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 104 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 240 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1072 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 187 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 504 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1073 (Linen) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 144 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 450 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1074 (JC) | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1075 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1076 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1077 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1078 | Room # Not Observed | ||||||||||||||||
| BSBRD | 0 | N/A | 18 SF | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| MSTC | 0 | N/A | 18 SF | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | |||||||||
| 7 | VFT | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | |||||||||
| 7 | MSTC | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97541-X | WALL-BRD | N/A | N/A | N/A | |||||||||
| ACT | 0 | N/A | 192 SF | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | |||||||||
| 5 | PLAS-W | CHR | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ||||||||||
| ROOM 1079 | |||||||||||||||||
| BSBRD | 0 | N/A | 14 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | Removed | ||||||||
| MSTC | 0 | N/A | 14 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | Removed | ||||||||
| 7 | VFT | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Abated | ||||||||
| 7 | MSTC | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | Abated | ||||||||
| WALL-BRD | 0 | N/A | 378 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 121 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | Abated | |||||||||
| ROOM 1080 | |||||||||||||||||
| BSBRD | 0 | N/A | 11 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | Removed | ||||||||
| MSTC | 0 | N/A | 11 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | Removed | ||||||||
| 7 | VFT | CHR | 48 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Abated | ||||||||
| 7 | MSTC | CHR | 48 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | Abated | ||||||||
| WALL-BRD | 0 | N/A | 288 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | Removed | ||||||||
| ACT | 0 | N/A | 64 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | Abated | |||||||||
| ROOM 1081 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 13 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | Removed | ||||||||
| MSTC | 0 | N/A | 13 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | Removed | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Abated | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | Abated | |||||||
| WALL-BRD | 0 | N/A | 342 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | Removed | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | MOD | Abated | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | Abated | ||||||||
| ACT | 0 | N/A | 90 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | Removed | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | Abated | ||||||||
| ROOM 1082 | |||||||||||||||||
| BSBRD | 0 | N/A | 13 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 13 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 360 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 100 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1084 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 16 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 16 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 432 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1085 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 15 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 15 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 100 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 100 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 414 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW | 5 | CHR | 97549-X | HW FITG | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97550-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 132 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1086 | Room # Not Observed | ||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| ROOM 1087 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1088 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 220 SF | 97543-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-DHW 5 | 5 | CHR | 10 LF | 97549-X | HW FITG | Y | GOOD | MOD | No Change | |||||||
| 7 | PIPE F-DCW | 5 | CHR | 10 LF | 97550-X | CW FITG | Y | GOOD | MOD | No Change | |||||||
| PLAS-W | 0 | N/A | 558 SF | 97543- | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1089 | |||||||||||||||||
| BSBRD | 0 | N/A | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | |||||||||
| MSTC | 0 | N/A | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | |||||||||
| 7 | VFT | 3 | CHR | 48 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 48 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 216 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 32 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1090 | |||||||||||||||||
| BSBRD | 0 | N/A | 15 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 15 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 396 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 120 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1091 | |||||||||||||||||
| BSBRD | 0 | N/A | 15 SF | 97334-X | 4'' BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 15 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 120 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 120 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 396 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 121 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1092 | |||||||||||||||||
| BSBRD | 0 | N/A | 34 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 34 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 560 SF | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 560 SF | 97537-X | MSTC FOR 97536 | N | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 918 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 560 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM C101 | |||||||||||||||||
| BSBRD | 0 | N/A | 15 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 15 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 414 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 120 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| ROOM C1010 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 936 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 352 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| ROOM C1011 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 360 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 75 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| ROOM C103 | |||||||||||||||||
| BSBRD | 0 | N/A | 54 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 54 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 1494 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 600 SF | 97865-X | 21X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| ROOM C104 | |||||||||||||||||
| BSBRD | 0 | N/A | 34 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 34 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 936 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 352 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| ROOM C105 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 58 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 58 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 640 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 640 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 640 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 1584 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ROOM C105A | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 38 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 38 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 400 SF | 97538-X | 1'X1' TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 400 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 640 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 1044 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ROOM C105B | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 22 SF | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 22 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 20 | CHR | 208 SF | 97539-X | MSTC FOR 97538 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 208 SF | 97540-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 612 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ROOM C107 | |||||||||||||||||
| MSTC | 0 | N/A | 15 SF | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 414 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ACT | 0 | N/A | 120 SF | 97865-X | 2'X4' THCK WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| ROOM C108 | |||||||||||||||||
| BSBRD | 0 | N/A | N/A | 97334-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | N/A | 97335-X | MSTC FOR 97334 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 252 SF | 97541-X | WALL-BRD | Y | GOOD | MOD | No Change |