BLDG200F8R2010.xls
XLS spreadsheet 175 KB Posted
- Attached to
- Z1DA--578-25-003 Renovate Elevators B200 (Construction) at the Hines VA Hospital in Hines, IL
- Solicitation number
- 36C25225R0036_3
About this file
This Excel file (BLDG200F8R2010.xls) is an asbestos materials inventory and abatement tracking document for Building 200's 8th floor, detailing the presence, location, and status of various potentially hazardous materials across multiple rooms. The document systematically catalogs materials such as vinyl floor tiles (VFT), mastics (MSTC), wall materials, baseboards, ceiling tiles, duct insulation, and other building components, with each entry marked as either "Removed" or "Abated" indicating the material's current status.
The inventory covers approximately 60-70 rooms (numbered 800-894 and C81-C89), with consistent material types recurring across different spaces. Common materials tracked include 9"x9" tan floor tiles with brown and white streaks, 4" black baseboards, wall-board, elevator plastics, and various insulation types. While the document does not specify the exact date of assessment, it appears to be a 2010 re-inspection report focused on identifying and documenting the removal or abatement of potential asbestos-containing materials, which is consistent with federal safety and environmental regulations for building maintenance and renovation.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLDG 200 8TH FL
| LOCATION | ACM % | TYPE | QTY | SAMPLE | MATERIAL DESCRIPTION | REEVALUATION 2010 | COMMENTS | Abated | Date | Work Order | Project No. | Report | Point of Contact | Notes | |||
| RANK | FUNCTION | FRIABLE | COND | POT FOR | This floor is renovated. No ACMs listed | ||||||||||||
| Y/N | DIST | here were seen in the 2010 re-inspection. | |||||||||||||||
| AREA 8TH FLOOR | |||||||||||||||||
| ROOM 800 | |||||||||||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9'' TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Removed | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| PLAS-W | N/A | N/A | N/A | 97548-X | ELV PLAS | N/A | N/A | N/A | Abated | ||||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | Abated | ||||||||
| ROOM 800A | |||||||||||||||||
| DUCT | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | |||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| PLAS-W | N/A | N/A | N/A | 97548-X | ELV PLAS | N/A | N/A | N/A | Removed | ||||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM 8006 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| ROOM 801 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | |||||||||
| N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | |||||||||
| N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | |||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 802 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | |||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 803 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 804 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 805 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 806 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 807 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 808 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 809 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 810 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| ACT | N/A | N/A | N/A | 97516-X | 2'X4' THK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 811 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 812 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| ACT | N/A | N/A | N/A | 97516-X | 2'X4' THK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 813 | |||||||||||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM 814 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 815 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 816 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 817 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 818 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| OTHR | N/A | N/A | N/A | 97329- | FIRE DOOR | ||||||||||||
| ROOM 819 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 820 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 821 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 822 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 823 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 824 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 825 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 25X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 827 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 828 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 829 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 830 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 831 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 832 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRO MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 833 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 834 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM 835 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| 7 | PLAS-W | N/A | N/A | N/A | 97327- | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| WALL-BRD | N/A | N/A | N/A | 97328- | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| ROOM 836 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326- | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 837 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| ROOM 837 | |||||||||||||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 838 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM 839 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 840 | |||||||||||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Removed | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM 841 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 842 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 843 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 844 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 845 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 846 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ROOM 846 | |||||||||||||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 847 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 848 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 849 | |||||||||||||||||
| NSFM, | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 850 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 6 | FIRESTOP | N/A | N/A | N/A | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | Abated | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 851 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 852 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BRN BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 854 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | ||||||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 855 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 856 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 857 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 858 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 859 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 860 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 861 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 862 | |||||||||||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ROOM 863 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 864 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | PIPE-DRN | N/A | N/A | N/A | 97524-X | DRAIN FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW 25 | N/A | N/A | N/A | 97525-X | ICE WATER FITG | N/A | N/A | N/A | Removed | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 865 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 866 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| VFT | N/A | N/A | N/A | 97526-X | GRY SHEET STAIRS | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97527-X | MSTC FOR 97526 | N/A | N/A | N/A | Removed | ||||||||
| ROOM 868 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ROOM 869 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ROOM 870 | N/A | N/A | N/A | Removed | |||||||||||||
| DUCT | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 871 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | PIPE-DRN | N/A | N/A | N/A | 97524-X | DRAIN FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW 20 | N/A | N/A | N/A | 97525-X | ICE WATER FITG | N/A | N/A | N/A | Removed | |||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 872 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 873 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 874 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ROOM 875 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 876 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| ROOM 877 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| ROOM 878 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Abated | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | |||||||||||
| ROOM 879 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 880 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BRN BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | ||||||||||||
| ROOM 881 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BRN BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 882 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| ROOM 882 | |||||||||||||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 884 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 885 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BRN BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM 886 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | Removed | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| VFT | N/A | N/A | N/A | 97526-X | GRY SHEET STAIRS | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97527-X | MSTC FOR 97526 | N/A | N/A | N/A | Removed | ||||||||
| ROOM 888 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | Removed | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Removed | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | Removed | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-A | N/A | N/A | N/A | 97326-X | PLAS | N/A | N/A | N/A | Removed | ||||||||
| PLAS-W | N/A | N/A | N/A | 97326-X' | PLAS | N/A | N/A | N/A | Removed | ||||||||
| 7 | PIPE F-DHW | N/A | N/A | N/A | 97549-X | HW FITG | N/A | N/A | N/A | Abated | |||||||
| 7 | PIPE F-DCW | N/A | N/A | N/A | 97550-X | CW FITG | N/A | N/A | N/A | Abated | |||||||
| ROOM 889 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Abated | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | |||||||||||
| ROOM 890 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Abated | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Removed | |||||||
| ROOM 891 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Abated | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Removed | |||||||
| ROOM 892 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Abated | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | |||||||||||
| ROOM 893 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | Removed | ||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| 5 | PLAS-W | N/A | N/A | N/A | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | Abated | |||||||
| ROOM C81 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| PLAS-W | N/A | N/A | N/A | 97548-X | ELV PLAS | N/A | N/A | N/A | Removed | ||||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM C810 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM C811 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | ||||||||||||
| ROOM C83 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | ||||||||||||
| ROOM C84 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Removed | ||||||||
| ROOM C84 | |||||||||||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Abated | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | ||||||||||||
| ROOM C85 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM C86 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM C87 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" ELK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM C88 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed | ||||||||
| MSTC | N/A | N/A | N/A | 97335-X | MSTC FOR 97334 | N/A | N/A | N/A | Abated | ||||||||
| 7 | VFT | N/A | N/A | N/A | 97536-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | Abated | |||||||
| 7 | MSTC | N/A | N/A | N/A | 97537-X | MSTC FOR 97536 | N/A | N/A | N/A | Removed | |||||||
| ACT | N/A | N/A | N/A | 97865-X | 2'X4' THCK WRM W/PNHL | N/A | N/A | N/A | Removed | ||||||||
| ROOM C89 | |||||||||||||||||
| WALL-BRD | N/A | N/A | N/A | 97328-X | WALL-BRD | N/A | N/A | N/A | Removed | ||||||||
| BSBRD | N/A | N/A | N/A | 97334-X | 4" BLK BSBRD | N/A | N/A | N/A | Removed |
This is the start of the file's text. The full file is on GovTribe.