BLDG200F13R2010.xls
XLS spreadsheet 204 KB Posted
- Attached to
- Z1DA--578-25-003 Renovate Elevators B200 (Construction) at the Hines VA Hospital in Hines, IL
- Solicitation number
- 36C25225R0036_3
About this file
This Excel file is a detailed asbestos survey and assessment document for Building 200, 13th Floor, cataloging various room materials and their potential asbestos-containing components. The document systematically inventories different room materials such as vinyl floor tiles (VFT), mastics (MSTC), baseboards (BSBRD), wall-board (WALL-BRD), and plaster surfaces across multiple rooms (Room 1300 through Room C139), noting their material type, quantity, condition, and potential asbestos presence.
The survey uses specific coding and classification systems to evaluate each material, with notations like "CHR" (potentially indicating chrysotile asbestos), condition ratings (such as "GOOD LOW"), and measurements in square feet. While the document does not indicate an active remediation project, it serves as a comprehensive inventory for potential future asbestos management or abatement efforts, providing detailed insights into the building's material composition and potential hazardous material risks.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLDG 200 13TH FL.
| LOCATION | ACM % | TYPE | QTY | SAMPLE | MATERIAL DESCRIPTION | REEVALUATION 2010 | COMMENTS | Abated | Date | Work Order | Project No. | Report | Point of Contact | Notes | |||
| RANK | FUNCTION | FRIABLE | COND | POT FOR | |||||||||||||
| Y/N | DIST | ||||||||||||||||
| AREA 13TH FLOOR | |||||||||||||||||
| ROOM 1300 | Room # Not Observed | ||||||||||||||||
| 7 | VFT | 3 | CHR | 375 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 375 SF | 97552-X | MSTC FOR 97551 | N/A | N/A | N/A | ||||||||
| ACT | 0 | N/A | 375 SF | 97559-X | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-CON | 20 | CHR | 97839-X | COND FITG | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 740 SF | 97841-X | ELV PLAS | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-STM | 30 | CHR | 97840- | STM FITG | N/A | N/A | N/A | |||||||||
| ROOM 1300A | Room # Not Observed | ||||||||||||||||
| 7 | VFT | 3 | CHR | 375 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 375 SF | 97552-X | MSTC FOR 97551 | N/A | N/A | N/A | ||||||||
| ACT | 0 | N/A | 300 SF | 97559-X | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-STM | 30 | CHR | 97840-X | STM FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-CON | 20 | CHR | 97839- | COND FITG | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 740 SF | 97841- | ELV PLAS | N/A | N/A | N/A | |||||||||
| ROOM 1300B | Room # Not Observed | ||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | |||||||||
| ROOM 1301 | Room # Not Observed | ||||||||||||||||
| MSTC | 0 | N/A | 15 SF | 97555-X | MSTC FOR 97556 | N/A | N/A | N/A | |||||||||
| BSBRD | 0 | N/A | 15 SF | 97556-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| ROOM 1303 | Room # Not Observed | ||||||||||||||||
| 7 | VFT | 3 | CHR | 320 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | ||||||||
| 7 | MSTC | 20 | CHR | 320 SF | 97552-X | MSTC FOR 97551 | N/A | N/A | N/A | ||||||||
| MSTC | 0 | N/A | 32 SF | 97555-X | MSTC FOR 97556 | N/A | N/A | N/A | |||||||||
| BSBRD | 0 | N/A | 32 SF | 97556-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| ROOM 1304 | Room # Not Observed | ||||||||||||||||
| 7 | VFT | 31 | CHR | 320 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 320 SF | 97552-X | MSTC FOR 97551 | N/A | N/A | N/A | ||||||||
| MSTC | 0 | N/A | 34 SF | 97555-X | MSTC FOR 97556 | N/A | N/A | N/A | |||||||||
| BSBRD | 0 | N/A | 34 SF | 97556-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| ROOM 1305 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 31 | CHR | 320 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | VFT Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 320 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 34 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 34 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| PLAS-A | 0 | N/A | 60 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 288 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1306 (Storage) | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 31 | CHR | 600 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 600 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 54 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 54 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE F-CON | 20 | CHR | 97839-X | COND FITG | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| VFT | 0 | N/A | 187 SF | 97836- | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 187 SF | 97837- | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 187 SF | 97838- | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1307 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 31 | CHR | 320 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 320 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 15 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 15 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 320 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 10 SF | 97833-X | 6" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 10 SF | 97834-X | MSTC FOR 97833 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 187 SF | 97835-X | 1'X1' TAN W/BRN,WHT THIN STRKS | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 187 SF | 97835-X | MSTC FOR 97835 LAB RESULTS | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 504 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1308 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | Room # Not Observed | ||||||||
| 7 | VFT | 31 | CHR | 320 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 320 SF | 97552-X | MSTC FOR 97551 | N/A | N/A | N/A | ||||||||
| ACT | 0 | N/A | 320 SF | 97559-X | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | N/A | N/A | N/A | |||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | N/A | N/A | N/A | |||||||||
| ROOM 1309 | Room # Not Observed | ||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| 7 | VFT | 31 | CHR | 320 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 320 SF | 97552-X | MSTC FOR 97551 | N/A | N/A | N/A | ||||||||
| ACT | 0 | N/A | 320 SF | 97559-X | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 432 SF | 97830-X | WALL-BRD | N/A | N/A | N/A | |||||||||
| MSTC | 0 | N/A | 187 SF | 97835-X | MSTC FOR 97835 LAB RESULTS | N/A | N/A | N/A | |||||||||
| ACT | 0 | N/A | 128 SF | 97838-X | 2'X4' POCK MARK | N/A | N/A | N/A | |||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ||||||||
| BSBRD | 0 | N/A | 15 SF | 97833- | 6" BRN BSBRD | N/A | N/A | N/A | |||||||||
| MSTC | 0 | N/A | 15 SF | 97834- | MSTC FOR 97833 | N/A | N/A | N/A | |||||||||
| VFT | 0 | N/A | 187 SF | 97835- | 1'X1' TAN W/BRN,WHT THIN STRKS | N/A | N/A | N/A | |||||||||
| ROOM 1310 | Room # Not Observed | ||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | |||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | |||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | N/A | N/A | N/A | |||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N/A | N/A | N/A | ||||||||
| MSTC | 0 | N/A | 19 SF | 97555-X | MSTC FOR 97556 | N/A | N/A | N/A | |||||||||
| BSBRD | 0 | N/A | 19 SF | 97556-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | |||||||||
| ACT | 0 | N/A | 160 SF | 97559-X | 2'X4' THIN WRM W/PNHL | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | N/A | N/A | N/A | |||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | N/A | N/A | N/A | |||||||||
| VFT | 0 | N/A | 410 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N/A | N/A | N/A | |||||||||
| 7 | MSTC | 5 | CHR | 410 SF | 97837-X | MSTC FOR 97836 | N/A | N/A | N/A | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | ||||||||
| ROOM 1311 | Room # Not Observed | ||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | N/A | N/A | N/A | |||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | N/A | N/A | N/A | |||||||||
| ROOM 1312 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | VFT Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 19 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1313 (Waiting Area) | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 19 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X. | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | NOT PRESENT, 2'X2' WHITE | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1314 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1315 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 19 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1316 (Toilet) | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Abated | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Abated | |||||||
| MSTC | 0 | N/A | 19 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Removed | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Removed | ||||||||
| ACT | 0 | N/A | 192 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| 7 | PIPE F-STM | 15 | CHR | 97831- | SECONDARY SUPPLY FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-CON | 15 | CHR | 97832- | SECONDARY RETURN FITG | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1317 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1318 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 29 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 792 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1319 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1320 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1321 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 29 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 484 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 20 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827- | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828- | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97829- | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| WALL-BRD | 0 | N/A | 792 SF | 97830- | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1322 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| ACT | 0 | N/A | 484 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 792 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1323 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1324 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1325 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 29 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 484 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 792 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1326 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 29 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 484 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 792 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1327 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1328A | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1328 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 10 SF | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | |||||||
| 7 | VFT | 3 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 29 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 484 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 10 LF | 97827-X | CW FITG | Y | GOOD | LOW | No Change | |||||||
| 7 | PIPE F-DHW | 20 | CHR | 10 LF | 97828-X | HW FITG | Y | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 792 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1329 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 29 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 484 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 792 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1330 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1331 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 192 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1332 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1333 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1334 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1335 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1336 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1337 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1338 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | CHR | 504 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | |||||||||
| ROOM 1339 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1340 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 5 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 3 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 20 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 187 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 0 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 504 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1341 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 15 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 3 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 20 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4'' BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 192 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1342 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 180 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1343 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 5 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 15 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 3 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 20 | CHR | 29 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 484 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 880 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1344 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 200 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1345 (Toilet) | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 0 | N/A | 200 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1346 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 6 | FIRESTOP | 15 | CHR | 97528-X | FIRESTOP WHT | Y | GOOD | LOW | No Change | ||||||||
| 7 | VFT | 3 | CHR | 440 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 440 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 29 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 29 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 484 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 880 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1347 | |||||||||||||||||
| WALL-BRD | 0 | N/A | 324 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| BSBRD | 0 | N/A | 10 SF | 97833-X | 6" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 10 SF | 97834-X | MSTC FOR 97833 | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 81 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 81 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 81 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| BSBRD | 0 | N/A | 30 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 30 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 10 LF | 97827-X | CW FITG | Y | GOOD | LOW | No Change | |||||||
| 7 | PIPE F-DHW | 20 | CHR | 10 LF | 97828-X | HW FITG | Y | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 1080 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 8000 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 8000 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT ' | 0 | N/A | 280 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-CON | 20 | CHR | 10 LF | 97839-X | COND FITG | Y | GOOD | LOW | No Change | |||||||
| 7 | PIPE F-STM | 30 | CHR | 97840-X | STM FITG | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349-1 | |||||||||||||||||
| BSBRD | 0 | N/A | 19 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 192 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 192 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 192 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349-2 | |||||||||||||||||
| BSBRD | 0 | N/A | 19 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 192 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 192 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 192 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349-3 | |||||||||||||||||
| BSBRD | 0 | N/A | 19 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 192 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 192 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 192 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349-4 | |||||||||||||||||
| BSBRD | 0 | N/A | 19 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 192 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 192 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 192 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349-5 | |||||||||||||||||
| BSBRD | 0 | N/A | 19 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 192 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 192 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 192 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349-6 | |||||||||||||||||
| BSBRD | 0 | N/A | 10 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 10 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 468 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 192 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 192 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 168 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349-7 | |||||||||||||||||
| BSBRD | 0 | N/A | 19 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 19 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 192 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 192 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 192 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1349-8 | |||||||||||||||||
| BSBRD | 0 | N/A | 10 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 10 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 504 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 192 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 192 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 192 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1350 | |||||||||||||||||
| BSBRD | 0 | N/A | 10 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 10 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 252 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 49 SF | 97836-X | 1'X1' TAN W/GRN & WHT STRKS | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 49 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 49 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1351 | |||||||||||||||||
| ACT | 0 | N/A | 80 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 360 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| BSBRD | 0 | N/A | 40 SF | 97833-X | 6" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 40 SF | 97834-X | MSTC FOR 97833 | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 80 SF | 97835-X | MSTC FOR 97835 LAB RESULTS | N | GOOD | LOW | No Change | ||||||||
| VFT | 0 | N/A | 80 SF | 97835-X | 1'X1' TAN W/BRN WHT STRK | N | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1353 | |||||||||||||||||
| BSBRD | 0 | N/A | 10 SF | 97340-X | 4" BRN BSBRD | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 10 SF | 97341-X | MSTC FOR 97340 | N | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 306 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| VFT | 0 | N/A | 72 SF | 97836-X | 1'X1' TAN W/GRN & WHT | N | GOOD | LOW | No Change | ||||||||
| 7 | MSTC | 5 | CHR | 72 SF | 97837-X | MSTC FOR 97836 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 72 SF | 97838-X | 2'X4' POCK MARK | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1354 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 13 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 13 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 99 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | Not Observed | ||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1355 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | N/A | N/A | N/A | No Change | |||||||||
| DUCT | N/A | N/A | N/A | N/A | N/A | N/A | N/A | No Change | |||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 13 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 13 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 100 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | Not Observed | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1356 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 192 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 560 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1357 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 48 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 48 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| ACT | 0 | N/A | 48 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | Not Observed | ||||||||
| WALL-BRD | 0 | N/A | 300 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1358 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 14 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 14 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 110 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | Not Observed | ||||||||
| WALL-BRD | 0 | N/A | 420 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1359 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 200 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 24 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1360 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 220 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 30 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1361 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 198 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 30 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1362 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1363 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 216 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 35 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1364 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | PIPE F-DCW | 20 | CHR | N/A | 97525-X | ICE WATER FITG | Y | GOOD | LOW | No Change | |||||||
| 7 | VFT | 3 | CHR | 357 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Abated | |||||||
| 7 | MSTC | 20 | CHR | 357 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Abated | |||||||
| MSTC | 0 | N/A | 19 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 357 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | Not Observed | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 10 LF | 97827-X | CW FITG | Y | GOOD | LOW | No Change | |||||||
| 7 | PIPE F-DHW | 20 | CHR | 10 LF | 97828-X | HW FITG | Y | GOOD | LOW | No Change | |||||||
| WALL-BRD | 0 | N/A | 760 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE-DRN | 15 | CHR | 97843-X | DRAIN FITG | Y | GOOD | LOW | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1365 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 13 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 13 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 132 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 460 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1366 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| VFT | 0 | N/A | 40 SF | 97347-X | GRY SHEET | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 40 SF | 97348-X | MSTC FOR 97347 | N | GOOD | LOW | No Change | ||||||||
| ROOM 1368 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | PIPE F-DCW | 20 | CHR | 97525-X | ICE WATER FITG | N/A | N/A | N/A | Not Observed | ||||||||
| PLAS-W | 0 | N/A | 738 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 330 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 7 | PIPE-DRN | 15 | CHR | 97843-X | DRAIN FITG | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1369 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 10 LF | 97827-X | CW FITG | Y | GOOD | LOW | No Change | |||||||
| 7 | PIPE F-DHW | 20 | CHR | 10 LF | 97828-X | HW FITG | Y | GOOD | LOW | No Change | |||||||
| PLAS-W | 0 | N/A | 558 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 220 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1370 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 13 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 13 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 132 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 460 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1371 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 357 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 357 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 19 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 357 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 10 LF | 97827-X | CW FITG | Y | GOOD | LOW | No Change | |||||||
| 7 | PIPE F-DHW | 20 | CHR | 10 LF | 97828-X | HW FITG | Y | GOOD | LOW | No Change | |||||||
| WALL-BRD | CHR | 760 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | |||||||||
| 5 | PLAS-W | 5 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| 7 | OTHR | 3 | CHR | 97843- | DRAIN FITG | N | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 15 | CHR | 97844- | CW FITG | Y | GOOD | LOW | |||||||||
| ROOM 1372 | |||||||||||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-A | 0 | N/A | 200 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1373 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| ACT | 0 | N/A | 135 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| PLAS-W | 0 | N/A | 480 SF | 97842- | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1374 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| ROOM 1375 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | |||||||||
| PLAS-W | 0 | N/A | 220 SF | 97842-X | PLAS | Y | GOOD | MOD | |||||||||
| PLAS-A | 0 | N/A | 30 SF | 97842-X | PLAS | Y | GOOD | MOD | |||||||||
| ROOM 1376 | |||||||||||||||||
| NSCM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| ROOM 1377 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| PLAS-W | 0 | N/A | 216 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| PLAS-A | 0 | N/A | 35 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1378 | |||||||||||||||||
| 77 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 18 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 18 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 192 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 560 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1379 | |||||||||||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 140 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 140 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 14 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 14 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 110 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 420 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1380 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 48 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 48 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| ACT | 0 | N/A | 48 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 200 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1381 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 13 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 13 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 99 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1382 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| DUCT | N/A | N/A | N/A | N/A | DUCT INS NS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CUR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 13 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 13 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 100 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 400 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1384 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 143 SF | 97551-X | 9"X9" TAN W/BRN WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 143 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | N/A | 16 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | ||||||||
| BSBRD | 0 | N/A | 16 SF | 97556-X | 4'' BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 143 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 480 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1385 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 132 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | No Change | |||||||
| 7 | MSTC | 20 | CHR | 132 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | No Change | |||||||
| MSTC | 0 | 15 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | No Change | |||||||||
| BSBRD | 0 | N/A | 15 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | No Change | ||||||||
| ACT | 0 | N/A | 132 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 460 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1386 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change | ||||||||
| NSWM | N/A | N/A | N/A | N/A | NSWM | N/A | N/A | N/A | No Change | ||||||||
| NSCM | N/A | N/A | N/A | N/A | NSCM | N/A | N/A | N/A | No Change | ||||||||
| VFT | 0 | N/A | 40 SF | 97347-X | GRY SHEET | N | GOOD | LOW | No Change | ||||||||
| MSTC | 0 | N/A | 40 SF | 97348-X | MSTC FOR 97347 | N | GOOD | LOW | No Change | ||||||||
| ROOM 1390 | |||||||||||||||||
| NSINS | N/A | N/A | N/A | N/A | NSINS | N/A | N/A | N/A | No Change | ||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Not Observed | |||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Not Observed | |||||||
| MSTC | 0 | N/A | 15 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Not Observed | ||||||||
| BSBRD | 0 | N/A | 15 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Not Observed | ||||||||
| ACT | 0 | N/A | 130 SF | 97559-X | 2'X4' THIN WRM W/PNHL | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DCW | 5 | CHR | 97827-X | CW FITG | Y | GOOD | LOW | No Change | ||||||||
| 7 | PIPE F-DHW | 20 | CHR | 97828-X | HW FITG | Y | GOOD | LOW | No Change | ||||||||
| WALL-BRD | 0 | N/A | 460 SF | 97830-X | WALL-BRD | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 10 SF | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | |||||||
| ROOM 1391 | Room # Not Observed | ||||||||||||||||
| 7 | VFT | 3 | CHR | 130 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N/A | N/A | N/A | ||||||||
| 7 | MSTC | 20 | CHR | 130 SF | 97552-X | MSTC FOR 97551 | N/A | N/A | N/A | ||||||||
| MSTC | 0 | N/A | 13 SF | 97555-X | MSTC FOR 97556 | N/A | N/A | N/A | |||||||||
| BSBRD | 0 | N/A | 13 SF | 97556-X | 4" BLK BSBRD | N/A | N/A | N/A | |||||||||
| WALL-BRD | 0 | N/A | 380 SF | 97830-X | WALL-BRD | N/A | N/A | N/A | |||||||||
| PLAS-A | 0 | N/A | 90 SF | 97842-X | PLAS | N/A | N/A | N/A | |||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | N/A | N/A | N/A | |||||||||
| ROOM 1392 | |||||||||||||||||
| 7 | VFT | 3 | CHR | 187 SF | 97551-X | 9"X9" TAN W/BRN & WHT STRKS | N | GOOD | LOW | Abated | |||||||
| 7 | MSTC | 20 | CHR | 187 SF | 97552-X | MSTC FOR 97551 | N | GOOD | LOW | Abated | |||||||
| MSTC | 0 | N/A | 19 SF | 97555-X | MSTC FOR 97556 | N | GOOD | LOW | Removed | ||||||||
| BSBRD | 0 | N/A | 19 SF | 97556-X | 4" BLK BSBRD | N | GOOD | LOW | Removed | ||||||||
| PLAS-A | 0 | N/A | 187 SF | 97842-X | PLAS | Y | GOOD | MOD | No Change | ||||||||
| 5 | PLAS-W | 3 | CHR | 97920-X | WALL-BRD MUD | Y | GOOD | MOD | No Change | ||||||||
| ROOM 1393 | |||||||||||||||||
| NSFM | N/A | N/A | N/A | N/A | NSFM | N/A | N/A | N/A | No Change |