This document provides details on a federal contract opportunity for infrastructure upgrades at a Veterans Affairs facility in New Orleans, Louisiana. The solicitation number is 36C77623B0038 and is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The opportunity type is a solicitation for construction services related to NOLA EHRM Infrastructure Upgrades at the New Orleans location. Specific requirements include performing upgrades to existing mechanical, electrical, and roofing systems across several buildings as depicted in the 21MB set of construction drawings referenced as file 2.7 - Drawings 07 of 17 - 00-MK-001 to 10-MJ-011.pdf. Responses to the solicitation are due on an unspecified date. The award date and any other contractual terms such as pricing or subcontracting goals are not included in this document.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CEILING AIR TERMINAL (ROUND)
FLEXIBLE DUCT
DUCT DOWN (ROUND)
DUCT UP (ROUND)
CD-1 12X12
100 CFM
PL105
A
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
DRAWING NUMBER WHERE DRAWN
PL105
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
DIRECTION OF PIPE PITCH (DOWN)
UNION
CAPPED OUTLET
POINT OF CONNECTION BETWEEN NEW AND
STRAINER
BALL VALVE
CHECK VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC OR MANUAL AIR VENT
PIPE OR DUCT BREAK (GRAPHIC ONLY -
COLD WATER PIPING
CONTINUOUS PIPE/DUCT)
(WALL TYPE)
DN
DN
UP
UP EXHAUST DUCT (UP & DOWN)
SUPPLY TOP REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN CEILING REGISTER OR GRILLE
EXHAUST OR RETURN REGISTER OR TOP GRILLE
DNUP RETURN DUCT (UP & DOWN)
SQUARE 3-WAY CEILING DIFFUSERS
SQUARE 2-WAY CEILING DIFFUSERS
SQUARE 1-WAY CEILING DIFFUSERS
EXHAUST OR RETURN CEILING REGISTER OR GRILLE
ROUND AND SQUARE 4-WAY CEILING DIFFUSERS
SECTION.)
10x8
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES EVEN IF
SYMBOL IS MISSING)
STANDARD RADIUS ELBOW (LONG RADIUS)
NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
LOUVER (LOUVER SPECIFIED IN ARCHITECTURAL
MANUAL VOLUME DAMPER
SUPPLY
RETURN45°
RETURN, NO SPLITTER (45° TAP)
STANDARD BRANCH SUPPLY OR
45°
AUTOMATIC CONTROL DAMPER MODULATING
EXISTING WORK
PUMP
S
T
DUCT SMOKE DETECTOR LOCATION (DETECTOR
PROVIDED BY DIVISION 26)
THERMOSTAT
TE TEMPERATURE SENSOR
VFD VARIABLE FREQUENCY DRIVE
DIFFUSER CALLOUT ( TYPE, SIZE, CFM)
PETE'S PLUG
STRAINER WITH BLOWDOWN VALVE & 3/4'' HOSE
CONNECTION
DRAIN/BLOWDOWN VALVE WITH 3/4'' HOSE
CONNECTION
SYMBOL
SYMBOL LEGEND
DESCRIPTION SYMBOL DESCRIPTION
COMBINATION FIRE/SMOKE DAMPER
1 HR FIRE RATED WALL
CEILING / WALL ACCESS PANEL
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
RISE OR DROP IN PIPE
THERMOMETER
PIPE UP
PIPE DOWN
GATE VALVE
AUTOMATIC AIR VENT
VENT PIPING
WASTE PIPING
HOT WATER CIRCULATION PIPING
HOT WATER PIPING
AV
CONNECT NEW DUCT TO EXISTING DUCT
BACK DRAFT DAMPER
BDD
FC
FLEXIBLE CONNECTION, EQUIPMENT,
VANED ELBOW (SHORT RADIUS)
EXISTING DUCT TO BE REMOVED
VIBRATION, OR SEISMIC
AUTOMATIC CONTROL DAMPER TWO
POSITION
EXISTING PIPE TO BE REMOVED
EXPANSION LOOP
TH TEMPERATURE AND HUMIDITY SENSOR
SUPPLY ARROW
EXHAUST ARROW
CONDENSATE PUMP
CIRCUIT SETTER
BALANCING VALVE
FLEXIBLE PIPE CONNECTION
EXPANSION JOINT
26-P-3
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
PUMP NO.3 IN BUILDING NO.26
EQUIPMENT ABBREVIATION (PUMP)
26-TU-I-I ITEM NUMBER (TERMINAL UNIT NO.1)
ITEM (TERMINAL UNIT SHOWN)
SERVED BY AIR HANDLER UNIT NO.1
BUILDING NO. WHERE EQUIPMENT IS LOCATED
VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF
RE RACK SENSOR
TRANSFER GRILLE
100FA
LEGACY ROOM NUMBER
100F8
ROOM DOOR TAG NUMBER
ROOM NAME
ROOM NAME
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP 629-22-700
LOCATION
''1
10% BASIS OF DESIGN 07.08.2022 CONSULTANT
CONSULTANT: A/E:
GDM
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
04-25-2023
FULLY
SPRINKLED
GDM
1584 MCNEIL ST, SUITE 200
DUPONT, WA 98327
P: 360.318.7095
JESSE BARKSDALE, LEED-AP, CPD
WWW.GDM-AE.COM
35% SCHEMATIC DESIGN 11.10.2022
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
65% DESIGN DEVELOPMENT 01.13.2023
03.17.202395% CONSTRUCTION DOCUMENTS
04.25.2023100% CONSTRUCTION DOCUMENTS
04-25-2023
A u to d e s k D o c s /2
-0
N e w
O rl e a n s
E H
R M
/2 -0
N e w O rl e a n s E
H R
M
M e c h
.r v t
00-MK-001
HVAC LEGEND, ABBREVIATION LIST, AND
GENERAL NOTES
JB KT
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% CONSTRUCTION
DOCUMENTS
GENERAL NOTES
1. PROVIDE SYSTEM STARTUP, TESTING, & ADJUSTMENTS OF INSTALLED
SYSTEMS TO MEET PERFORMANCE REQUIREMENTS INDICATED IN THE
CONTRACT DOCUMENTS.
2. CONTRACTOR SHALL SUPPORT SYSTEM COMMISSIONING AND SHALL
COORDINATE WITH PROJECT COMMISSIONING AGENT.
3. CONTRACTOR SHALL PROVIDE ALL DOCUMENTATION REQUIRED TO SUPPORT
SYSTEM COMMISSIONING.
4. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND
CONSTRUCTION FEES. FURNISH COPIES OF ALL CONSTRUCTION PERMITS,
FINAL APPROVED PERMITS, AND SIMILAR DOCUMENTS TO OWNER
DOCUMENTING COMPLIANCE WITH CODE REQUIREMENTS.
5. LOCATE ALL VALVES, TRAPS, TEST PORTS, DAMPERS, CONTROLS,
CLEANOUTS, ETC. TO BE ACCESSIBLE FOR MAINTENANCE, ADJUSTMENT, &
TESTING. PROVIDE ACCESS PANELS FOR ALL CONCEALED DEVICES. ACCESS
PANEL LOCATIONS SHALL BE COORDINATED WITH ARCHITECT.
6. ALL PIPING & DUCTWORK IN FINISHED ROOMS OR SPACES SHALL BE
CONCEALED IN A FURRED CHASE OR ABOVE THE SUSPENDED CEILING
SYSTEM. REFER TO ARCHITECTURAL DOCUMENTS FOR FURRING & CHASE
LOCATIONS & SIZES.
7. THE FIRST FIGURE OF DUCT SIZE CALLOUTS INDICATES DIMENSION OF FACE
SHOWN OR INDICATED. DUCT SIZES ARE NET INSIDE DIMENSIONS. PROVIDE
ANY APPLICABLE DUCT LINING AND INSULATION PER THESE PLANS AND
SPECIFICATIONS. NOMINAL OUTER DUCT DIMENSIONS ARE NET INSIDE
DIMENSIONS PLUS 2X INSULATION THICKNESS.
8. DUCTWORK SHALL BE 2.0" PRESSURE CLASS UNLESS OTHERWISE NOTED ON
THESE DRAWINGS.
9. CONSTRUCT DUCTWORK ACCORDING TO INTERNATIONAL ENERGY
CONSERVATION CODE SECTION C403.11.2.
10. PROVIDE TURNING VANES IN ALL MITERED RECTANGULAR DUCT ELBOWS &
TEES.
11. PROVIDE MANUAL BALANCING DAMPERS ON ALL NEW AND MODIFIED DUCT
BRANCHES TO AIR INLETS & OUTLETS. LOCATE DAMPERS AS CLOSE TO MAIN
TRUNK DUCT CONNECTION AS POSSIBLE. WHERE BRANCH DUCTWORK IS
INACCESSIBLE (SUCH AS ABOVE HARD LID CEILING SYSTEM), PROVIDE
BALANCING DAMPER AT REGISTER, GRILLE, OR DIFFUSER.
12. PROVIDE MOTORIZED DAMPERS ON OUTDOOR AIR SUPPLY, EXHAUST
OPENINGS, AND RELIEF OUTLETS. DAMPERS SHALL HAVE A MAXIMUM
LEAKAGE RATE OF 4 CFM PER SQUARE FOOT AT 1” W.C.
13. RELIEF GRAVITY DAMPERS SHALL HAVE A MAXIMUM LEAKAGE RATE OF 20
CFM PER SQUARE FOOT AT 1” W.C. DAMPERS SMALLER THAN 24” IN EITHER
DIRECTION SHALL HAVE A MAXIMUM LEAKAGE RATE OF 40 CFM PER SQUARE
FOOT AT 1” W.C.
14. PROVIDE COMPLETE CONDENSATE DRAINAGE SYSTEM FOR ALL SPLIT
SYSTEMS, VRF SYSTEMS, AND SIMILAR SYSTEMS WITH REFRIGERANT OR
CHILLED WATER COOLING INSTALLED PER THIS PROJECT. FIELD ROUTE
DRAINAGE PIPING FROM EQUIPMENT TO NEAREST DRAIN LOCATION (SUCH AS
SERVICE SINK, FUNNEL DRAIN, ETC.). SLOPE NON-PRESSURIZED DRAIN
PIPING TO DRAIN LOCATION. PIPING & FITTINGS SHALL BE COPPER. MINIMUM
PIPE SIZE SHALL BE 3/4". INCREASE PIPE SIZE WHERE APPLICABLE PER
INTERNATIONAL MECHANICAL CODE 307.2.2.
15. SIZE REFRIGERANT PIPING ON SPLIT SYSTEM UNITS PER MANUFACTURER'S
RECOMMENDATION.
16. TOTAL STATIC PRESSURE NOTED IN SCHEDULES SHALL BE ASSUMED TO
INCLUDE DUCT SYSTEM, TERMINAL UNITS, FILTERS, COILS, ETC.
17. ALL SUPPLY AIR FILTERS SHALL BE MERV-11 RATED. ALL
RETURN/EXHAUST/OUTSIDE AIR FILTERS SHALL BE MERV-11 RATED.
18. AIR INLET & OUTLET SIZES SHOWN ON PLANS ARE NECK SIZES. PROVIDE
ADDITIONAL PANS, HARDWARE, ETC., REQUIRED TO INSTALL AIR INLETS &
OUTLETS IN CEILING SYSTEM.
19. WALL REGISTER-TYPE AIR INLETS & OUTLETS SHALL BE INSTALLED AT 7" AFF
MINIMUM ELEVATION.
20. AIR INLETS & OUTLETS IN UNFINISHED SPACES OR OPEN CEILING AREAS
SHALL BE INSTALLED AT 96" AFF UNLESS OTHERWISE NOTED ON THESE
DRAWINGS.
21. ALL PRESSURES LISTED ARE GAGE PRESSURES UNLESS OTHERWISE NOTED.
22. COORDINATE ALL MECHANICAL, PLUMBING & FIRE PROTECTION WORK WITH
OTHER TRADES TO INSURE PROPER AND ADEQUATE INTERFACE OF THEIR
WORK WITH THE WORK SHOWN ON THESE DOCUMENTS. CONTRACTOR SHALL
PROVIDE COORDINATED SHOP DRAWINGS FOR APPROVAL PRIOR TO
FABRICATION AND INSTALLATION.
23. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH NFPA
70 STANDARDS AND LOCAL REQUIREMENTS.
24. ALL FIELD WIRING SHALL REQUIRE AN ELECTRICAL PERMIT AND SHALL BE
PERFORMED BY A LICENSED ELECTRICIAN.
25. A SHORT DASH IN A SCHEDULE TABLE CELL INDICATES THAT THE COLUMN
HEADING IS NOT USED OR NOT APPLICABLE TO THAT SCHEDULED ITEM.
26. MAINTAIN AND RESTORE (IF INTERRUPTED) ALL CONDUITS & CONDUCTORS,
PIPING, & DUCTWORK PASSING THROUGH RENOVATED AREAS AND
SERVICING UNDISTURBED AREAS.
27. REMOVE ALL ABANDONED DUCTWORK, PIPING, CONTROLS, WIRING, ETC.,
WHERE ACCESSIBLE IN RENOVATED AREAS.
28. WHERE CONTROLS ARE DEMOLISHED, REMOVE WIRING BACK TO NEAREST
CONTROL PANEL OR JUNCTION BOX. REMOVE ACCESSIBLE CONDUIT,
JUNCTION BOXES, ETC.
29. OWNER SHALL HAVE FIRST RIGHT OF REFUSAL FOR ALL EQUIPMENT AND
COMPONENTS REMOVED DURING DEMOLITION.
30. CONTRACTOR SHALL PROVIDE AND INSTALL ISOLATION VALVES IN SUPPORT
OF ALL PIPED EQUIPMENT AND UPDATE AS-BUILT DRAWINGS ON FINAL
PLACEMENT.
31. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL CUTTING &
RESTORATION WORK NECESSARY IN EXISTING AREAS OF THE BUILDING TO
PROVIDE WORK SHOWN ON THESE DOCUMENTS. REFER TO ARCHITECTURAL
DOCUMENTS FOR RESTORATION REQUIREMENTS. CUTTING WORK SHALL
INCLUDE SAWCUTTING, CORE-DRILLING, AND ALL SIMILAR WORK AS
REQUIRED BY THE TYPE OF CONSTRUCTION BEING PENETRATED OR
MODIFIED.
32. WHERE DIRECTION REGARDING RESTORATION AT SPECIFIC LOCATIONS OF
CUTTING, CORE-DRILLING, & SIMILAR ACTIVITIES DOES NOT EXIST IN THE
ARCHITECTURAL DOCUMENTS, RESTORATION SHALL INCLUDE PATCHING TO
MATCH EXISTING SURROUNDING CONSTRUCTION AND FINISHES. PATCHED
AREAS SHALL BE RE-PAINTED FULL HEIGHT OF WALL FROM WALL CORNER TO
WALL CORNER.
33. PROVIDE DRIP TRAY WITH LEAK DETECTOR MONITORED BY AND CONNECTED
TO DDC SYSTEM AT ALL LOCATIONS WHERE CONDENSING UNITS, INDOOR
UNITS, CONDENSATE PIPING, CW PIPING, OR ANY OTHER LIQUID-CARRYING
ELEMENTS ARE LOCATED ABOVE DATA EQUIPMENT. DRIP TRAYS SHALL BE
PROVIDED WITH 120V POWERED CONDENSATE PUMP. PROVIDE 3/4"
CONDENSATE DRAIN PIPING FROM PUMP TO DRAIN LOCATION. PUMPED
CONDENSATE DRAIN PIPING MAY BE CONNECTED TO OTHER PUMPED OR
GRAVITY CONDENSATE DRAIN PIPES IN THE SAME ROOM. COORDINATE WITH
EC TO PROVIDE 120V POWER FOR CONDENSATE PUMP.
ABBREVIATIONS LIST
°F DEGREES FAHRENHEIT
(E) EXISTING
A AMPERES
A/E ARCHITECT/ENGINEER
ABV ABOVE
AMPS AMPERES
AFF ABOVE FINISHED FLOOR
ASJ ALL SURFACE JACKET
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
BTUH BRITISH THERMAL UNITS PER HOUR
CFM CUBIC FEET PER MINUTE
CFSD COMBINATION FIRE/SMOKE DAMPER
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CW COLD WATER
COND CONDENSATE
DDC DIRECT DIGITAL CONTROL
DIA DIAMETER
DN DOWN
EA EXHAUST AIR
EC ELECTRICAL CONTRACTOR
ECM ELECTRONICALLY CONTROLLED MOTOR
EER ENERGY EFFICIENCY RATIO
ELEC ELECTRICAL
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
F FAHRENHEIT
FLA FULL LOAD AMPS
FLR FLOOR
FPM FEET PER MINUTE
FSD FIRE SMOKE DAMPER
FT FEET
GPF GALLONS PER FLUSH
GPM GALLONS PER MINUTE
GR GRAINS
GYP GYPSUM
H HEIGHT
HP HORSEPOWER
HR HOUR
HW HOT WATER
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
IN INCH
INDW INDIRECT WASTE
KW KILOWATT
KWH KILOWATT PER HOUR
LB POUND
LBS POUNDS
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH THOUSAND BRITISH THERMAL UNITS PER HOUR
MCA MINIMUM CIRCUIT AMPACITY
MCR MAIN COMPUTER ROOM
MFG MANUFACTURE
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
MRT MEAN RADIANT TEMPERATURE
NRC NOISE REDUCTION COEFFICIENT
OA OUTSIDE AIR
ORL OVERFLOW RAIN LEADER
PC PRESSURE CONDENSATE
PD PRESSURE DROP
PH PHASE
PVC POLYVINYL CHLORIDE
RA RETURN AIR
RL RAIN LEADER
RH RELATIVE HUMIDITY
RM ROOM
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SCOP SEASONAL COEFFICIENT OF PERFORMANCE
SEER SEASONAL ENERGY EFFICIENCY RATIO
SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL
ASSOCIATION
SQ FT SQUARE FEET
TEMP TEMPERATURE
TYP TYPICAL
V VENT
V VOLT
VA UNITED STATES DEPARTMENT OF VETERAN'S AFFAIRS
VFD VARIABLE FREQUENCY DRIVE
W/ WITH
W WASTE
W WATT
W WIDTH
W.C. WATER COLUMN
WG WATER GAUGE
Revisions: Date:
HANGER ROD UP TO
ATTACHMENT TO CEILING
STRUCTURE (TYP)
METAL CHANNEL STRUT
PIPE MOUNTING
STRAP (TYP)
PIPING (TYP)
GALVANIZED PIPE SHIELD
TO PROTECT PLASTIC
PIPING (TYP)
PIPE SADDLE (TYP)
STEEL STRAP
PIPE HANGER
ALL THREAD ROD
ATTACH TO STRUCTURE
PIPE
PROVIDE GALVANIZED PIPE SHIELD TO
PROTECT PLASTIC PIPING (PIPE SHIELDS
SHALL SURROUND ENTIRE PIPE
CIRCUMFERENCE)
6" MIN
PROVIDE GALVANIZED PIPE
SHIELD TO PROTECT PLASTIC PIPING
(PIPE SHIELDS SHALL SURROUND
ENTIRE PIPE CIRCUMFERENCE)
TURNBUCKLE
PIPE
EYE BOLT
TURNBUCKLE
INSULATION
PROVIDE GALVANIZED PIPE
SHIELD BETWEEN HANGER AND
INSULATION UP TO CENTERLINE OF PIPE
STEEL STRAP
PIPE
RIGID INSULATION
PIPE
PIPE INSULATION
10" MIN
6" MIN
PROVIDE GALVANIZED PIPE
SHIELD BETWEEN HANGER AND
INSULATION UP TO CENTERLINE
OF PIPE
PIPE HANGER
ALL THREAD ROD
ATTACH TO
STRUCTURE
EYE BOLT
RIGID INSULATION
STEEL STRAP
PIPE
EYE BOLT
PROVIDE GALVANIZED PIPE
SHIELD TO PROTECT PLASTIC PIPING (PIPE
SHIELDS SHALL SURROUND ENTIRE PIPE
CIRCUMFERENCE)
TURNBUCKLE
INSULATION
PROVIDE GALVANIZED PIPE
SHIELD BETWEEN HANGER AND
INSULATION UP TO CENTERLINE
OF PIPE
STEEL STRAP
PIPE
EYE BOLT
RIGID
INSULATION
CONDENSATE DRAIN
SIZE PER PLANS.
CLEANOUT
1-1/2" P-TRAP
PLUMBING FIXTURE AS
SHOWN ON PLANS
VENT PIPE
SIDE VIEW
FURRED-OUT WALL
CONDENSATE
CONNECTION
SLIP JOINT
NUT AND SEAL
ESCUTCHEON
1-1/2" FEMALE NPT
CONNECTION
JR SMITH 9200 CONDENSATE TRAP
16 GAUGE x 1" WIDE
HANGER STRAP.
SECURE EACH STRAP TO DUCT
WITH (2) #10 SELF TAPPING SHEET
METAL SCREWS.
SUPPLY DUCT. SEE
PLANS FOR DUCT SIZE.
NOTE:
1. PROVIDE AND CONSTRUCT DUCT HANGERS AND SUPPORTS PER 2006 SMACNA HVAC DUCT CONSTRUCTION STANDARDS FIGURE 5-5.
2. LENGTH OF SUPPORTS, STRAP SIZES, AND SIZES OF STEEL ANGLES AS REQUIRED FOR DUCT SIZE AND CONFIGURATION.
3. MAXIMUM 10' SPACING BETWEEN SUPPORTS.
4. DUCTS SHALL BE SUPPORTED INDEPENDENTLY AT EQUIPMENT AND ON BOTH SIDES OF AN EXPANSION OR FLEXIBLE JOINT.
5. HANGER SUPPORTS SHALL BE SECURELY FASTENED TO THE BUILDING OR STRUCTURE.
16 GAUGE x 1" WIDE
HANGER STRAP.
SECURE EACH STRAP TO DUCT
WITH (2) #10 SELF TAPPING
SHEET METAL SCREWS.
SUPPLY DUCT. SEE
PLANS FOR DUCT SIZE.
SPRING VIBRATION
ISOLATORS SPRING VIBRATION
ISOLATORS
6" MAX
SEE PLANS FOR DUCT SIZE
18 GA METAL
STRAP 1'' WIDE
(2) NUTS WITH WASHER AND
LOCK-WASHER.
THREADED ROD. ATTACH
TO STRUCTURE.
SHEET METAL CAN SAME
SIZE AS DIFFUSER NECK
T-BAR / HARD LID CEILING SYSTEM
COLLAR
FLEXIBLE DUCT
AIR INLET OR OUTLET
NOTE: NOTE:
1. USE THIS TYPE OF CONNECTION WHERE THERE IS
ENOUGYH CEILING SPACE TO KEEP KINGS OUT OF
FLEXIBLE DUCTS.
2. T-BAR CEILING SHOWN, USE GRILLES CONFIGURED
FOR HARD LID CEILING OR SURFACE MOUNTING FOR
HARD LID CEILING APPLICATIONS.
FLEXIBLE DUCT
AIR INLET OR OUTLET
T-BAR / HARD LID CEILING SYSTEM
SQUARE TO ROUND
TRANSISTION
1. USE THIS TYPE OF CONNECTION IN CONSTRICTED
CEILING SPACES.
2. T-BAR CEILING SHOWN, USE GRILLES CONFIGURED
FOR HARD LID CEILING OR SURFACE MOUNTING FOR
HARD LID CEILING APPLICATIONS.
WATER RETURN
WATER SUPPLY
MV
MANUAL AIR VENT
TEST PLUG (TYP)
UNION CONNECTIONS (TYP)
REDUCER, IF REQUIRED
SHUT OFF VALVE
3-WAY MODULATING CONTROL
VALVE WITH ELECTRONIC
ACTUATOR
WYE STRAINER WITH BLOWDOWN
VALVE & HOSE CONNECTIONS
FLEX HOSE CONNECTIONS
THESE COMPONENTS MAY BE PROVIDED
AS PART OF MANUFACTURER-ASSEMBLED
COIL CONNECTION KIT
NOTES:
1. ALL COIL CONNECTIONS SHALL BE MADE IN A COUNTER FLOW CONFIGURATION.
2. SUPPORT PIPING INDEPENDENT FROM CONNECTED COIL AND TERMINAL UNIT.
CRAC UNIT
CIRCULATION PUMP
CRAC UNIT
CHILLED WATER RETURN
CHILLED WATER SUPPLY
MV
MANUAL AIR VENT
TEST PLUG (TYP)
UNION CONNECTIONS (TYP)
REDUCER, IF REQUIRED
SHUT OFF VALVE
PRESSURE INDEPENDENT 2-WAY
CONTROL
VALVE WITH ELECTRONIC ACTUATOR
WYE STRAINER WITH BLOWDOWN
VALVE & HOSE CONNECTIONS
FLEX HOSE CONNECTIONS
THESE COMPONENTS MAY BE PROVIDED
AS PART OF MANUFACTURER-ASSEMBLED
COIL CONNECTION KIT
NOTES:
1. ALL COIL CONNECTIONS SHALL BE MADE IN A COUNTER FLOW
CONFIGURATION.
2. SUPPORT PIPING INDEPENDENT FROM CONNECTED COIL AND TERMINAL UNIT.
CIRCULATION PUMP
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP 629-22-700
LOCATION
''1
10% BASIS OF DESIGN 07.08.2022 CONSULTANT
CONSULTANT: A/E:
GDM
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
GDM
1584 MCNEIL ST, SUITE 200
DUPONT, WA 98327
P: 360.318.7095
JESSE BARKSDALE, LEED-AP, CPD
WWW.GDM-AE.COM
35% SCHEMATIC DESIGN 11.10.2022
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
65% DESIGN DEVELOPMENT 01.13.2023
03.17.202395% CONSTRUCTION DOCUMENTS
04.25.2023100% CONSTRUCTION DOCUMENTS
04-25-2023
A u to d e s k D o c s /2
-0
N e w
O rl e a n s
E H
R M
/2 -0
N e w O rl e a n s E
H R
M
M e c h
.r v t
00-MK-500
DETAILS
JB ADR
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% CONSTRUCTION
DOCUMENTS
TYPICAL PIPE SUPPORT DETAIL
TYPICAL INDIRECT DRAIN DETAIL
TYPICAL DUCT SUPPORT DETAIL
AIR INLET AND OUTLET DETAIL
CRAC UNIT WATER COILS - 3-WAY PIPING CONNECTIONS
CRAC UNIT WATER COILS - 2 WAY PIPING CONNECTION
ALL THREAD (TYP)
DEHUMIDIFICATION UNIT
UNISTRUT SUPPORT
DOUBLE NUTS ABOVE AND BELOW
UNISTRUT, WITH WASHERS BETWEEN
NUTS AND UNISTRUT
EXTERIOR WALL
FLASHING COLLAR
CAULK ALL AROUND
WALL CAP, SIZED AS SHOWN
ON PLANS
2"
2"
MOTORIZED 2-POSITION
DAMPER INTERLOCKED WITH
DEHUMIDIFICATION UNIT
CAT-6 (MINIMUM) ETHERNET CABLE
CONNECT TO NETWORK SWITCH
FRONT/BOTTOM TEMPERATURE
SENSOR (CENTERED, MAXIMUM 1'
FROM BOTTOM OF CABINET)
RACK-MOUNT ENVIRONMENTAL
MONITOR WITH INTEGRAL
TEMPERATURE & HUMIDITY SENSORS
(4' +/-6" FROM BOTTOM OF CABINET)
REAR TOP TEMPERATURE SENSOR
(CENTERED, MAXIMUM 1' FROM TOP
OF CABINET)
DATA CABINET
SENSOR WIRING
FRONT/TOP TEMPERATURE SENSOR
(CENTERED, MAXIMUM 1' FROM TOP OF
CABINET)
NOTES:
1. ATTACH SENSORS TO DATA CABINET/RACK. DO NOT ATTACH TO CABINET DOOR.
CONDENSING UNIT
WALL SUPPORT BRACKET (TYP)
NOTES:
1) PROVIDE WALL SUPPORT SYSTEM TO MEET UNIT WEIGHT AND SIZE.
2) WALL SUPPORT TO BE MINIMUM 7 FEET AFF.
3) PROVIDE WALL SUPPORT SYSTEM TO MEET SEISMIC RESTRAINT REQUIREMENTS.
4) PROVIDE MOUNTING HARDWARE TO ATTACH UNIT TO WALL SUPPORTS AS RECOMMENDED BY UNIT MANUFACTURER.
PIPE
150# RAISED FACE
FLANGES (TYP)
SUPPORT ROD (TYP)
EXPANSION LOOPS
STACKED EXPANSION LOOP
PIPE (TYP)
150# RAISED FACE
FLANGES (TYP)
SUPPORT ROD
EXPANSION LOOP
EXPANSION LOOP
FULL PORT BALL VALVE (TYP)
PRESSURE GAUGE (TYP)
2-4 PIPE DIAMETERS MAX (TYP)
INLINE PUMP
HANGER ROD UP TO STRUCTURE
CLEVIS PIPE HANGER
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP 629-22-700
LOCATION
''1
10% BASIS OF DESIGN 07.08.2022 CONSULTANT
CONSULTANT: A/E:
GDM
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
GDM
1584 MCNEIL ST, SUITE 200
DUPONT, WA 98327
P: 360.318.7095
JESSE BARKSDALE, LEED-AP, CPD
WWW.GDM-AE.COM
35% SCHEMATIC DESIGN 11.10.2022
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
65% DESIGN DEVELOPMENT 01.13.2023
03.17.202395% CONSTRUCTION DOCUMENTS
04.25.2023100% CONSTRUCTION DOCUMENTS
04-25-2023
A u to d e s k D o c s /2
-0
N e w
O rl e a n s
E H
R M
/2 -0
N e w O rl e a n s E
H R
M
M e c h
.r v t
00-MK-501
DETAILS
JB ADR
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% CONSTRUCTION
DOCUMENTS
DEHUMIDIFICATION UNIT SUPPORT
DUCT PENETRATION OF WALL WITH WALL CAP
DATA CABINET MONITORING DETAIL
WALL SUPPORT DETAIL
EXPANSION LOOP DETAIL
INLINE PUMP DETAIL
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP 629-22-700
LOCATION
''1
10% BASIS OF DESIGN 07.08.2022 CONSULTANT
CONSULTANT: A/E:
GDM
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
04-25-2023
FULLY
SPRINKLED
GDM
1584 MCNEIL ST, SUITE 200
DUPONT, WA 98327
P: 360.318.7095
JESSE BARKSDALE, LEED-AP, CPD
WWW.GDM-AE.COM
35% SCHEMATIC DESIGN 11.10.2022
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
65% DESIGN DEVELOPMENT 01.13.2023
03.17.202395% CONSTRUCTION DOCUMENTS
04.25.2023100% CONSTRUCTION DOCUMENTS
04-25-2023
A u to d e s k D o c s /2
-0
N e w
O rl e a n s
E H
R M
/2 -0
N e w O rl e a n s E
H R
M
M e c h
.r v t
00-MK-600
SCHEDULES
JB KT
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% CONSTRUCTION
DOCUMENTS
1. ASJ SHALL INCLUDE VAPOR BARRIER.
NOTES:
SUPPLY & RETURN AIR DUCT INSULATION IN UNCONDITIONED SPACE 12.00 - - 4.40 - X FIBERGLASS WITH ASJ 1
SUPPLY & RETURN AIR DUCT INSIDE BUILDING 6.00 - - 2.00 - X FIBERGLASS WITH ASJ 1
OUTSIDE AIR TO INDOOR CONDENSING UNIT, INSIDE CONDITIONED SPACE 12.00 - - 4.40 - X FIBERGLASS WITH ASJ 1
OUTSIDE AIR TO INDOOR CONDENSING UNIT, IN UNCONDITIONED SPACE 21.00 - - 7.70 - X FIBERGLASS WITH ASJ 1
INDOOR CONDENSING UNIT EXHAUST, INSIDE CONDITIONED SPACE 6.00 - - 2.00 - X FIBERGLASS WITH ASJ 1
INDOOR CONDENSING UNIT EXHAUST, IN UNCONDITIONED SPACE 6.00 - - 2.00 - X FIBERGLASS WITH ASJ 1
(MIN) (MAX) (MIN, 1") (IN) INSIDE DUCT OUTSIDE DUCT
APPLICATION R-VALUE K-VALUE NRC THICKNESS INSULATION LOCATION TYPE NOTES
DUCT INSULATION & LINING SCHEDULE
1. PROVIDE WITH TEMPERING VALVE. TEMPERING VALVE TO BE LOCATED IN WALL WITH AN ACCESS PANEL OR EXPOSED UNDER SINK.
NOTES:
01-P-504 LAVATORY STAINLESS STEEL, 18"X18", UNDERMOUNT, GOOSENECK FAUCET, WRIST BLADE HANDLES 2.00 - 1.50 0.50 0.50 0.50 - UNDERMOUNT - WHITE - - - - 1
WASTE INDW VENT HW CW GPM GPF (LBS) W AMP VOLT PHASE
SYMBOL FIXTURE DESCRIPTION PLUMBING CONNECTIONS (IN) FLOW MOUNTING WEIGHT FINISH ELECTRICAL NOTES
PLUMBING FIXTURE SCHEDULE
1. PROVIDE WITH ECM MOTOR
NOTES:
03-CP-41 BELL AND GOSSETT ECOCIRC 20-18 03-CRAC-41 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
03-CP-31 BELL AND GOSSETT ECOCIRC 20-18 03-CRAC-31 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
03-CP-21 BELL AND GOSSETT ECOCIRC XL 36-45 03-CRAC-21 INLINE CENTRIFUGAL 13 - 28.00 8.40 - 4,600 0.16 200 120 1 INLINE 16 1
03-CP-11 BELL AND GOSSETT ECOCIRC 20-18 03-CRAC-11 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
02-CP-31 BELL AND GOSSETT ECOCIRC 20-18 02-CRAC-31 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
01-CP-41 BELL AND GOSSETT ECOCIRC 20-18 01-CRAC-32 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
01-CP-32 BELL AND GOSSETT ECOCIRC 20-18 01-CRAC-32 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
01-CP-31 BELL AND GOSSETT ECOCIRC 20-18 01-CRAC-31 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
01-CP-22 BELL AND GOSSETT ECOCIRC 20-18 01-CRAC-22 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
01-CP-21 BELL AND GOSSETT ECOCIRC 20-18 01-CRAC-21 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
01-CP-13 BELL AND GOSSETT ECOCIRC 20-18 01-CRAC-13 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
01-CP-12 BELL AND GOSSETT ECOCIRC XL 55-45 01-CRAC-12 INLINE CENTRIFUGAL 13 - 40.00 12.00 - 4,600 0.50 500 208 1 INLINE 22 1
01-CP-11 BELL AND GOSSETT ECOCIRC 20-18 01-CRAC-11 INLINE CENTRIFUGAL 8 - 15.00 4.50 - 4,800 0.06 100 120 1 INLINE 10 1
GPM (DESIGN) GPM (MIN) (FT) HEAD (FT) (FT) HP W VOLT PHASE (LBS)
SYMBOL MANUFACTURER MODEL SERVICE TYPE FLOW HEAD CONTROL NPSHR RPM ELECTRICAL MOUNTING WEIGHT NOTES
PUMP SCHEDULE
4. PROVIDE WITH WALL MOUNTED THERMOSTAT/HUMIDITY SENSOR.
3. PROVIDE WITH BACNET DDC INTERFACE.
2. PROVIDE WITH CONDENSATE PUMP. CONDENSATE PUMP SHALL BE POWERED BY INDOOR UNIT.
1. COMPUTER ROOM AIR CONDITIONING UNIT WITH DEDICATED HUMIDIFICATION AND DEHUMIDIFICATION CAPABILITIES.
NOTES:
05-CRAC-14 BLDG K ROOM 1L108 LIEBERT MMD24E CEILING 21.3 19.1 - - - - 966 0.40 0.00 208 1 22.3 27.9 30 225 1,2,3,4
05-CRAC-13 BLDG K ROOM 1L107 LIEBERT MMD24E CEILING 21.3 19.1 - - - - 966 0.40 0.00 208 1 22.3 27.9 30 225 1,2,3,4
05-CRAC-12 BLDG K ROOM 1L110 LIEBERT DME027E WALL 21.8 21.5 - - - - 1098 0.40 0.00 208 1 22.3 27.9 30 225 1,2,3,4
05-CRAC-11 BLDG L ROOM 1L110 LIEBERT DME027E WALL 21.8 21.5 - - - - 1098 0.40 0.00 208 1 22.3 27.9 30 225 1,2,3,4
04-CRAC-14 BLDG K ROOM 1K104 LIEBERT DME027E WALL 21.8 21.5 - - - - 1098 0.40 0.00 208 1 22.3 27.9 30 225 1,2,3,4
04-CRAC-13 BLDG K ROOM 1K104 LIEBERT DME027E WALL 21.8 21.5 - - - - 1098 0.40 0.00 208 1 22.3 27.9 30 225 1,2,3,4
04-CRAC-12 BLDG K ROOM 1K103 LIEBERT DME027E WALL 21.8 21.5 - - - - 1098 0.40 0.00 208 1 22.3 27.9 30 225 1,2,3,4
04-CRAC-11 BLDG K ROOM 1K103 LIEBERT DME027E WALL 21.8 21.5 - - - - 1098 0.40 0.00 208 1 22.3 27.9 30 225 1,2,3,4
03-CRAC-41 BLDG H ROOM 4H113 LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
03-CRAC-31 BLDG H ROOM 3H130A LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
03-CRAC-21 BLDG H ROOM 2H200C LIEBERT MM92C DUCTED CONCEALED 60.8 50.0 45 55 13.3 16 2500 2.00 0.20 208 3 43.2 54 60 498 1,2,4
03-CRAC-11 BLDG H ROOM 1H211 LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
02-CRAC-31 BLDG D ROOM 3D101-E LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
01-CRAC-41 BLDG B ROOM 4B161A LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
01-CRAC-32 BLDG C ROOM 3C152A LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
01-CRAC-31 BLDG B ROOM 3B161A LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
01-CRAC-22 BLDG C ROOM 2C152A LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
01-CRAC-21 BLDG B ROOM 2B161A LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
01-CRAC-13 BLDG C ROOM 1C228 LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
01-CRAC-12 BLDG C ROOM 1C114C LIEBERT MM92C DUCTED CONCEALED 60.8 50.0 45 55 13.3 16 2500 2.00 0.20 208 3 43.2 54 60 498 1,2,4
01-CRAC-11 BLDG B ROOM 1B179 LIEBERT PW011UC FLOOR 40.2 33.8 45 55 7.5 4.1 2000 0.75 0.20 208 3 35.3 44.1 45 575 1,2,3,4
MBH MBH °F °F FT CFM HP ESP (IN WG) VOLT PHASE FLA MCA MOCP (LBS)
SYMBOL SERVES MANUFACTURER MODEL TYPE TOTAL COOLING SENSIBLE COOLING CHILL WATER SUPPLY CHILL WATER RETURN GPM WATER PD SUPPLY FAN ELECTRICAL WEIGHT NOTES
COMPUTER ROOM INDOOR UNIT
1. PROVIDE WITH PROTECTIVE CAGE.
NOTES:
05-DHU-02 MUNTERS HC-150 BLDG L ROOM 1L110 150 55 3.2 6 6 - 2.90 - 208 1 70 1
05-DHU-01 MUNTERS HC-150 BLDG L ROOM 1L107 150 55 3.2 6 6 - 2.90 - 208 1 70 1
04-DHU-02 MUNTERS HC-150 BLDG K ROOM 1K104 150 55 3.2 6 6 - 2.90 - 208 1 70 1
04-DHU-01 MUNTERS HC-150 BLDG K ROOM 1K103 150 55 3.2 6 6 - 2.90 - 208 1 70 1
(CFM) (GR/HR) SUPPLY RETURN KW AMP VOLT PHASE (LBS)
SYMBOL MANUFACTURER MODEL SPACE SERVED CFM REACTIVATION AIRFLOW LOAD RUNOUT SIZE (INCH) DRAIN ELECTRICAL WEIGHT NOTES
DEHUMIDIFIER SCHEDULE
NOTES:
05-CU-14 05-CRAC-14 LIEBERT PFH027A_PLN AIR-COOLED 2 2.69 93.3 208 1 20.5 24.8 30 241
05-CU-13 05-CRAC-13 LIEBERT PFH027A_PLN AIR-COOLED 2 2.69 93.3 208 1 20.5 24.8 30 241
05-CU-12 05-CRAC-12 LIEBERT PFH027A_PLN AIR-COOLED 2 2.69 93.3 208 1 20.5 24.8 30 241
05-CU-11 05-CRAC-11 LIEBERT PFH027A_PLN AIR-COOLED 2 2.69 93.3 208 1 20.5 24.8 30 241
04-CU-14 04-CRAC-14 LIEBERT PFH027A_PLN AIR-COOLED 2 2.69 93.3 208 1 20.5 24.8 30 241
04-CU-13 04-CRAC-13 LIEBERT PFH027A_PLN AIR-COOLED 2 2.69 93.3 208 1 20.5 24.8 30 241
04-CU-12 04-CRAC-12 LIEBERT PFH027A_PLN AIR-COOLED 2 2.69 93.3 208 1 20.5 24.8 30 241
04-CU-11 04-CRAC-11 LIEBERT PFH027A_PLN AIR-COOLED 2 2.69 93.3 208 1 20.5 24.8 30 241
TONS DB ( °F) VOLT PHASE FLA MCA MOCP (LBS)
SYMBOL SERVES MANUFACTURER MODEL TYPE NOMINAL SCOP DESIGN TEMP ELECTRICAL WEIGHT NOTES
COMPUTER ROOM AIR CONDITIONER SYSTEMS - CONDENSING UNIT SCHEDULE
NOTES:
WC-2 BROAN 643FA SUPPLY PAINT TO MATCH EXISTING EXTERIOR COLOR
WC-1 BROAN 643 EXHAUST PAINT TO MATCH EXISTING EXTERIOR COLOR
SYMBOL MANUFACTURER MODEL FINISH NOTES
WALL CAP SCHEDULE
3. PROVIDE WITH VAPOR BARRIER.
2. PROVIDE WITH ALUMINUM JACKETING IN ALL EXTERIOR LOCATIONS.
1. PROVIDE WITH PVC JACKETING IN ALL EXPOSED LOCATIONS (UTILITY ROOMS, STORAGE ROOMS, ETC.).
NOTES:
REFRIGERANT PIPING 0-150 0.25-0.29 125 1.50 1.50 2.00 - - FLEXIBLE ELASTOMERIC 2,3
HYDRONIC PIPING 40-140 0.21-0.28 100 1.50 1.50 2.00 2.00 2.00 FIBERGLASS W/ ASJ 1,2,3
CW 40-60 0.28-0.27 75 0.50 0.50 1.00 1.00 1.00 FIBERGLASS W/ ASJ 1,2,3
CONDENSATE DRAIN 40-60 0.21-0.27 75 - 1.00 1.00 1.00 1.00 FLEXIBLE ELASTOMERIC 2,3
( °F) K FACTOR MRT ( °F) <1" 1" - 1-1/4" 1-1/2" - 3" 4" - 8" >8"
APPLICATION TEMP RANGE INSULATION CONDUCTIVITY NOMINAL PIPE SIZE (IN) TYPE NOTES
PIPE INSULATION SCHEDULE
5. PROVIDE MANUAL AIR DAMPERS AT EACH BRANCH DUCT TO A SINGLE DIFFUSER, REGISTER OR GRILLE.
4. COORDINATE AIR TERMINAL TYPE WITH THE ARCHITECTURAL REFLECTED CEILING PLAN.
3. FURNISH ALL PRODUCTS OF A SINGLE MANUFACTURER.
2. PROVIDE ALL RETURN, EXHAUST AND TRANSFER GRILLES AND REGISTERS WITH FIXED 35 º OR 45 º DEFLECTION BLADES UNLESS OTHERWISE NOTED.
1. REFER TO PLANS FOR SIZE AND QUANTITY.
NOTES:
EG-1 PRICE 630 EXHAUST DUCT/GYP BOARD GRILLE PRIME COAT 1,2,3,4,5
TG-1 PRICE 630 TRANSFER DUCT/GYP BOARD GRILLE PRIME COAT 1,2,3,4
RG-1 PRICE 630 RETURN DUCT/GYP BOARD GRILLE PRIME COAT 1,2,3,4,5
SD-1 PRICE 620 SUPPLY DUCT/GYP BOARD GRILLE PRIME COAT 1,3,4,5
SYMBOL MANUFACTURER MODEL SERVICE MOUNTING TYPE STYLE MATERIAL NOTES
AIR INLETS AND OUTLETS SCHEDULE
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP 629-22-700
LOCATION
''1
10% BASIS OF DESIGN 07.08.2022 CONSULTANT
CONSULTANT: A/E:
GDM
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
GDM
1584 MCNEIL ST, SUITE 200
DUPONT, WA 98327
P: 360.318.7095
JESSE BARKSDALE, LEED-AP, CPD
WWW.GDM-AE.COM
35% SCHEMATIC DESIGN 11.10.2022
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
65% DESIGN DEVELOPMENT 01.13.2023
03.17.202395% CONSTRUCTION DOCUMENTS
04.25.2023100% CONSTRUCTION DOCUMENTS
04-25-2023
A u to d e s k D o c s /2
-0
N e w
O rl e a n s
E H
R M
/2 -0
N e w O rl e a n s E
H R
M
M e c h
.r v t
00-MK-601
SEQUENCE OF OPERATIONS
JB ADR
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% CONSTRUCTION
DOCUMENTS
SEQUENCE OF OPERATIONS
1. NEW COMPUTER ROOM AIR CONDITIONING UNIT — TR SPACES
1.1 DESCRIPTION: COMPUTER ROOM AIR CONDITIONING UNITS SHALL PROVIDE TEMPERATURE AND
HUMIDITY CONTROL FOR THE SPACES THAT THEY SERVE USING MANUFACTURER’S CONTROL
SEQUENCES.
1.2 SPACE CONDITIONING: CRAC UNITS SHALL RECEIVE TEMPERATURE AND HUMIDITY SETPOINTS FROM THE BUILDING DDC SYSTEM. THE UNITS SHALL OPERATE DURING BOTH OCCUPIED AND UNOCCUPIED HOURS USING MANUFACTURER’S PREPROGRAMMED SEQUENCES TO HEAT, COOL, DEHUMIDIFY, AND HUMIDIFY THE SPACE TO MAINTAIN CONDITION REQUIREMENTS SPECIFIED FOR THE DATA CENTER
EQUIPMENT.
1.3 SPACE CONDITION MONITORING: THE DDC SYSTEM SHALL MONITOR THE SPACE USING DEDICATED TEMPERATURE AND HUMIDITY SENSORS. IF CONDITIONS IN THE SPACE ARE ABOVE OR BELOW THE
ALLOWABLE CONDITIONS (USER ADJUSTABLE MIN AND MAX SETPOINTS FOR TEMPERATURE AND
HUMIDITY) FOR 5 MIN (ADJUSTABLE) OR MORE, AN ALARM SHALL BE INITIATED ON THE DDC SYSTEM.
1.4 FIRE SHUTDOWN: THE HVAC SYSTEM WILL SHUTDOWN ON A FIRE ALARM SIGNAL FROM THE BUILDING FIRE ALARM SYSTEM. THIS IS DONE THRU AN INTERLOCKING SAFETY RELAY THAT REMOVES CONTROL
POWER TO THE DDC.
1.4.1 FANS SHALL BE DEACTIVATED.
1.4.2 COMPRESSORS SHALL BE DEACTIVATED.
1.5 HUMIDITY SENSOR AND TEMPERATURE SENSOR
1.5.1 DDC MONITORING (TE): DDC TO MONITOR AND TREND THE ROOM TEMPERATURE.
1.5.2 DDC MONITORING (HE): DDC TO MONITOR AND TREND THE ROOM RELATIVE HUMIDITY.
1.5.3 ALARM: TEMPERATURE SENSOR (TE): DDC TO MONITOR TEMPERATURE AND SEND AN ALARM IF
TEMPERATURE OUTSIDE TEMPERATURE SETPOINT BY 5°F FOR MORE THAN 5 MINUTES (USER
ADJUSTABLE FOR TIME AND VALUE OUTSIDE RANGE).
1.5.4 ALARM: HUMIDITY SENSOR (HE): DDC TO MONITOR RELATIVE HUMIDITY AND SEND AN ALARM
UPON FAILURE TO MEET HUMIDITY SETPOINTS.
1.6 HUMIDITY AND TEMPERATURE SEPOINTS — TR SPACES
1.6.1 TEMPERATURE
1.6.1.1 LOW TEMPERATURE SETPOINT: 64°F
1.6.1.2 HIGH TEMPERATURE SETPOINT: 81°F
1.6.2 HUMIDITY
1.6.2.1 LOW HUMIDITY SETPOINT: 30% RH
1.6.2.2 HIGH HUMIDITY SETPOINT: 60% RH
2. EXISTING HVAC SYSTEMS — TR SPACES
2.1 DESCRIPTION: EXISITNG HVAC SYSTEMS INCLUDING VAV, COMPUTER ROOM AIR CONDITIONING UNITS OR OTHERS SHALL REMAIN IN OPERATION TO PROVIDE TEMPERATURE AND HUMIDITY CONTROL FOR
THE SPACES THAT THEY SERVE. EXISTING CONTROL SEQUENCES TO REMAIN UNCHANGED, WITH
UPDATED SETPOINTS BELOW.
2.2 SPACE CONDITION MONITORING: THE DDC SYSTEM SHALL MONITOR THE SPACE USING NEW
DEDICATED TEMPERATURE AND HUMIDITY SENSORS. IF CONDITIONS IN THE SPACE ARE ABOVE OR
BELOW THE ALLOWABLE CONDITIONS (USER ADJUSTABLE MIN AND MAX SETPOINTS FOR
TEMPERATURE AND HUMIDITY) FOR 5 MIN (ADJUSTABLE) OR MORE, AN ALARM SHALL BE INITIATED ON
THE DDC SYSTEM.
2.3 HUMIDITY AND TEMPERATURE SENSORS
2.3.1 DDC MONITORING (TE): DDC TO MONITOR AND TREND THE ROOM TEMPERATURE.
2.3.2 DDC MONITORING (HE): DDC TO MONITOR AND TREND THE ROOM RELATIVE HUMIDITY.
2.3.3 ALARM: TEMPERATURE SENSOR (TE): DDC TO MONITOR TEMPERATURE AND SEND AN ALARM IF
TEMPERATURE OUTSIDE TEMPERATURE SETPOINT BY 5°F FOR MORE THAN 5 MINUTES (USER
ADJUSTABLE FOR TIME AND VALUE OUTSIDE RANGE).
2.3.4 ALARM: HUMIDITY SENSOR (HE): DDC TO MONITOR RELATIVE HUMIDITY AND SEND AN ALARM
UPON FAILURE TO MEET HUMIDITY SETPOINTS.
2.4 HUMIDITY AND TEMPERATURE SEPOINTS — TR SPACES
2.4.1 TEMPERATURE
2.4.1.1 LOW TEMPERATURE SETPOINT: 64°F
2.4.1.2 HIGH TEMPERATURE SETPOINT: 81°F
2.4.2 HUMIDITY
2.4.2.1 LOW HUMIDITY SETPOINT: 30% RH
2.4.2.2 HIGH HUMIDITY SETPOINT: 60% RH
3. COMPUTER ROOM AIR CONDITIONING UNIT SPACES WITH DEHUMIDIFIER UNITS: 1K103, 1K104, 1L107, 1L110 — TR
SPACES
3.1 DESCRIPTION: COMPUTER ROOM AIR CONDITIONING UNITS SHALL PROVIDE TEMPERATURE AND
HUMIDITY CONTROL FOR THE SPACES THAT THEY SERVE USING MANUFACTURER’S CONTROL
SEQUENCES.
3.2 SPACE CONDITIONING: CRAC UNITS SHALL RECEIVE TEMPERATURE AND HUMIDITY SETPOINTS FROM THE BUILDING DDC SYSTEM. THE UNITS SHALL OPERATE DURING BOTH OCCUPIED AND UNOCCUPIED HOURS USING MANUFACTURER’S PREPROGRAMMED SEQUENCES TO HEAT, COOL, DEHUMIDIFY, AND HUMIDIFY THE SPACE TO MAINTAIN CONDITION REQUIREMENTS SPECIFIED FOR THE DATA CENTER
EQUIPMENT.
3.2.1 CRAC UNITS SHALL BE THE FIRST STAGE OF DEHUMIDIFICATION.
3.2.2 DEHUMIDIFIER UNITS SHALL BE SECOND STAGE OF DEHUMIDIFICATION. UNIT SETPOINTS
SHALL BE ADJUSTED SO THAT DEHUMIDIFIERS ACTIVATE IF CRAC UNITS CANNOT MAINTAIN
REQUIRED SPACE HUMIDITY RANGE.
3.3 SPACE CONDITION MONITORING: THE DDC SYSTEM SHALL MONITOR THE SPACE USING DEDICATED TEMPERATURE AND HUMIDITY SENSORS. IF CONDITIONS IN THE SPACE ARE ABOVE OR BELOW THE
ALLOWABLE CONDITIONS (USER ADJUSTABLE MIN AND MAX SETPOINTS FOR TEMPERATURE AND
HUMIDITY) FOR 5 MIN (ADJUSTABLE) OR MORE, AN ALARM SHALL BE INITIATED ON THE DDC SYSTEM.
3.4 FIRE SHUTDOWN: THE HVAC SYSTEM WILL SHUTDOWN ON A FIRE ALARM SIGNAL FROM THE BUILDING FIRE ALARM SYSTEM. THIS IS DONE THRU AN INTERLOCKING SAFETY RELAY THAT REMOVES CONTROL
POWER TO THE DDC.
3.4.1 FANS SHALL BE DEACTIVATED.
3.4.2 COMPRESSORS SHALL BE DEACTIVATED.
3.4.3 DEHUMIDIFICATION UNIT SHALL BE DEACTIVATED.
3.5 HUMIDITY SENSOR AND TEMPERATURE SENSOR
3.5.1 DDC MONITORING (TE): DDC TO MONITOR AND TREND THE ROOM TEMPERATURE.
3.5.2 DDC MONITORING (HE): DDC TO MONITOR AND TREND THE ROOM RELATIVE HUMIDITY.
3.5.3 ALARM: TEMPERATURE SENSOR (TE): DDC TO MONITOR TEMPERATURE AND SEND AN ALARM IF
TEMPERATURE OUTSIDE TEMPERATURE SETPOINT BY 5°F FOR MORE THAN 5 MINUTES (USER
ADJUSTABLE FOR TIME AND VALUE OUTSIDE RANGE).
3.5.4 ALARM: HUMIDITY SENSOR (HE): DDC TO MONITOR RELATIVE HUMIDITY AND SEND AN ALARM
UPON FAILURE TO MEET HUMIDITY SETPOINTS.
3.6 HUMIDITY AND TEMPERATURE SEPOINTS — TR SPACES
3.6.1 TEMPERATURE
3.6.1.1 LOW TEMPERATURE SETPOINT: 75°F
3.6.1.2 HIGH TEMPERATURE SETPOINT: 81°F
3.6.2 HUMIDITY
3.6.2.1 LOW HUMIDITY SETPOINT: 30% RH
3.6.2.2 HIGH HUMIDITY SETPOINT: 60% RH
4. CONNECT TO RUN INDICATION DRY CONTACT.
3. PROVIDE RELAY AS NECESSARY TO ENABLE/DISABLE POWER TO UNIT.
2. SPACE TEMPERATURE AND HUMIDITY MAY BE PROVIDED AS SEPARATE SENSORS OR COMBINED SENSOR UNITS.
1. PROVIDE GATEWAY IF REQUIRED TO CONNECT FACTORY UNIT CONTROLLER TO DDC SYSTEM.
NOTES:
RUN INDICATION X 4
UNIT ALARM X 5
ENABLE/DISABLE X 3
DEHUMIDIFICATION UNIT
SPACE HUMIDITY AND TEMPERATURE X X X X X X X 2
HUMIDITY AND TEMPERATURE SENSOR X X X X
UNIT ALARM X
FIRE ALARM SHUTDOWN X X X
UNIT ENABLE COMMAND X X X X
SCHEDULE COMMAND X X X
COOLING SETPOINT X X X
SPACE AIR TEMPERATURE SETPOINT X X X
HUMIDIFIER COMMAND X X X
SUPPLY FAN STATUS X X X X X
RETURN AIR HUMIDITY X X X
RETURN AIR TEMPERATURE X X X
COMPUTER ROOM AIR CONDITIONING UNIT X X 1
T E
M P
E R
A T
U R
E
P R
E S
S U
R E
R E
LA
T
IV
E
H U
M
ID
IT
Y
G P
M
C F
M
P E
R C
E N
T
B T
U H
R
K W
K W
H
S E
T P
O
IN
T
S T
A T
U S
O N
/O F
F
F
IL
T E
R S
T A
T U
S
S T
A T
U S
O P
E N
/C
LO
S E
D
S T
A T
U S
N O
. O F
S T
A R
T S
T
IM
E D
O V
E R
R
ID
E
O N
/O F
F
O P
E N
/C
LO
S E
LO
C
K O
U T
E N
A B
LE
/D
IS
A
B
LE
H
IG
H A
N A
LO
G
LO
W
A N
A
LO
G
H
IG
H B
IN
A
R Y
LO
W
B
IN
A R
Y
P R
O O
F
S E
N S
O R
F A
IL
F
LO
W F
A
IL
C O
M M
U N
IC
A
T
IO
N S
F A
IL
D
IA
G N
O S
T
IC
S
G E
N E
R A
L A
LA
R
M
G R
A P
H
IC
S
T R
E N
D
IN
G
T
IM
E S
C H
E D
U
LI
N G
INPUT OUTPUT INPUT OUTPUT ALARMS PROGRAMS
SYSTEM POINT DESCRIPTION ANALOG BINARY SYSTEM FEATURES NOTES
SYSTEM POINTS LIST - HVAC SYSTEMS
UP
UP
UP
01-MJ-011
01-MJ-013
01-MJ-012
01-MJ-011
01-MJ-012
01 B
01 9.2
01 4
01 4.2
01-MJ-013
01 2
01 G 01 H 01 J 01 K 01 L 01 M01 F01 C01 D01 A01 A.4
M.1 01 E
01 E
01 1
01 8
01 9
01 7
01 9.6
01 1.4
01 3
01-MJ-011
01-MJ-011
01 5
01 6
01 6.3
01 8.2
CHF (OC)
1C220
A CHF (OC)
1C222
SECY (OC)
1B208
ITAC (OC)
1B141
CS (OC)
1B139
OFF CHF (FS)
1B151
BA (OC)
1C224
ADM (OC)
1B140
MA ASST (OC)
1C226
CUB (FS)
1B193A
CUB (FS)
1B175C
CUB (FS)
1B192A
MEDIA (FS)
1B154
OFF A CHF
(FS)
1B152
CUB CST SRV
(FS)
1B150
SEC/WAIT (FS)
1B153
CHF (CD)
1B159
A CHF (CD)
1B158
LD CODE (CD)
1B162
LD CODE (CD)
1B161
CUB (CD)
1B172B
CUB (CD)
1B170A
CUB (CD)
1B170C
CUB (CD)
1B173B
CUB (CD)
1B173A
CUB (CD)
1B170D
CUB (CD)
1B170B
CUB (CD)
1B171A
CUB (CD)
1B172C
SECY (CD)
1B160
WORK (CD)
1B157
A CHF (HIM)
1B143
CHF (HIM)
1B144
SECY (HIM)
1B201
CUB (HIM)
1B195A
CUB (HIM)
1B193B
WAIT/ROI
(HIM)
1B200
CHF (WA)
1B137
A CHF (WA)
1B138
SECY (WA)
1B134
OP CTR (WA)
1B130
OFF SPV (WA)
1B132
A CHF (HE)
1C135
CUB (MCCF)
1B174A
CUB (MCCF)
1B175A
CUB (MCCF)
1B174B
BUS CTR (HE)
1C125
T
1B176
CHIEF
1C203
A CHF
1C201
TECH
1C196A
WORKROOM
1C205
SUPV (MCCF)
1B155
IP SUP (HE)
1C134
IP CLRK (HE)
1C124
SECY (MCCF)
1C132B
CUB PSA (HE)
1C130B
CUB PSA (HE)
1C130A
CUB PSA (HE)
1C130C
ADMIS (HE)
1C122
CUB ELIG (HE)
1C131
CUB PSA (HE)
1C132D
A CHF
1C199
ACCNT CHF
1C214 ACCNT CHF
1C213
ACCNT CHF
1C212
ACCNT CHF
1C211
COMP
AUDITOR
1C215
COMP
OFFICER
1C216
BDGT
1C192E
BDGT
1C192B
BDGT
1C192A
BDGT
1C192F
BDGT
1C217A
TECH
1C192D
TECH
1C192C
TECH
1C200A
TECH
1C194A
TECH
1C217B
TECH
1C196C
AUDITOR
1C193
AUDITOR
1C197
AUDITOR
1C195
RECPT
1C190A
T
1C186
T
1C219
AUDITOR
1C191
BREAK
1C210
SERVICE BAY
1C114
EC
1C223
EC
1B180
SERVICE BAY
1B123
TR
1C114C
1A104B
NORM ELEC
1C114A
DETAILS (HE)
1C136
WAIT (OC)
1C227
CUB CS (HE)
1C132C
STOR (HE)
1C126
EMER ELEC
1C114B
TR
1B123D
1B114A
EMER ELEC
1B123A
NORM ELEC
1B123B
SEC/WAIT
1B106
CONF/CLASS
(OC)
1B135
T
1B204
CUB (FS)
1B191A
T
1B178
TR
1C228
1C149
WAIT
1C190
SERV ELEV
LOBB
1B120
PUB ELEV
LOBBY
1B100
WORKROOM
(HIM)
1B194
CLINICAL
SUPER (NSA)
1B102
CLINICAL
SUPER (NSA)
1B103
T
1C141
T
1C143
WC
1C144
LOUNGE
1C145
RECPT
1C137
PANTRY
1C146
CHAPLAIN
1B105
CHAPLAIN
1B107
CHAPLAIN
1B109
EUCHARIST
1B111
QUIET
1B116
T
1B108
T
1B110
STOR
1B112
HK
1B114
STOR/FILE
(FS)
1B190
ISO (HIM)
1B203
PV (HIM)
1B142
STOR
1C196B
SLEEP
1C166 T/S
1C166A
ST
1C181
T/S
1C179A
T/S
1C174A
SLEEP
1C174
SLEEP
1C165 SLEEP
1C175
T/S
1C165A
T/S
1C164A
SLEEP
1C164
SLEEP
1C177
T/S
1C177A
T/S
1C175A
SLEEP
1C179SLEEP
1C162
T/S
1C162A
WAIT
1C160
CC
1C178 CONF
1C185
RETAIL AREA
1C101
VESTIBULE
1C150
ADMIS (HE)
1C123
STOR
1C221
WAIT
1C132A
MONITOR
1C163
POLY
1C161
EQUIP
1C168 T
1C160A
BREAK
1C169
ELEV
BS-1
FUTURE ELEV
BS-2
ELEV
BS-4
ELEV
BS-3
STAIR
STB-1
CORR
1B-C01
CORR
1B-C02
CORR
1B-C03
AISLE
1B-C08
CORR
1B-C07
CORR
1B-C05
CORR
1B-C06
AISLE
1B-C09
AISLE
1B-C10
AISLE
1B-C11
AISLE
1B-C12
AISLE
1B-C13
AISLE
1B-C14
AISLE
1B-C15
AISLE
1B-C16
AISLE
1C-C01A
AISLE
1C-C01B
AISLE
1C-C01C
AISLE
1C-C01D
AISLE
1C-C03
AISLE
1C-C04
AISLE
1C-C04AAISLE
1C-C04B
AISLE
1C-C05
AISLE
1C-C06
AISLE
1C-C07
AISLE
1C-C12
AISLE
1C-C11
AISLE
1C-C09
AISLE
1C-C08
AISLE
1C-C08A
SECY (HE)
1B172A
STOR
1C133
HK
1C139
VESTIBULE
1B121
CORR
1C101-K
CORR
1B-C02A
HK
1B206
NOUR
1C180
AISLE
1C-C010
AISLE
1C-C07A
SECURITY
1C114D
1C104A
UNASSIGNED
1B174GSECURITY
1B123C
CORR
1C-C02
SECY/WAIT
(OC)
1C225
RETAIL PREP
1C101A
CORR
1B-C04
AISLE
1B-C04A
AISLE
1C-C00
CORR
1C-C01
CLEAN
1C167
SOILED
1C176
CONNECTOR
HALL
1B115A
TR
1B179
1B145
IT/LVSR
1C190B
CHAPEL
1B115
CLOSET
1B115B
1-1/4" CHS/R UP. SEE 2/01-MJ-021
FOR CONTINUATION
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP 629-22-700
LOCATION
''1
10% BASIS OF DESIGN 07.08.2022 CONSULTANT
CONSULTANT: A/E:
GDM
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
04-25-2023
FULLY
SPRINKLED
GDM
1584 MCNEIL ST, SUITE 200
DUPONT, WA 98327
P: 360.318.7095
JESSE BARKSDALE, LEED-AP, CPD
WWW.GDM-AE.COM
35% SCHEMATIC DESIGN 11.10.2022
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
65% DESIGN DEVELOPMENT 01.13.2023
03.17.202395% CONSTRUCTION DOCUMENTS
04.25.2023100% CONSTRUCTION DOCUMENTS
04-25-2023
A u to d e s k D o c s /2
-0
N e w
O rl e a n s
E H
R M
/2 -0
N e w O rl e a n s E
H R
M
M e c h
.r v t
01-MH-011
FIRST FLOOR HVAC PLAN - BUILDINGS B
AND C
JB KT
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% CONSTRUCTION
DOCUMENTS
3/32" = 1'-0"1
FIRST FLOOR HVAC PLAN BUILDINGS B & C
KEY PLAN
D
E
F
G
K
H
J1 J2
M3 M1 M2
N1 N2
P
Q B1 B2
C1 C2
NORTH
B & C
DN
UP
DN
UP
DN
DN
UP
01-MJ-022
01-MJ-022
01-MJ-024
01-MJ-024
01-MJ-021
01-MJ-021
01-MJ-023
01-MJ-023
01 B
01 9.2
01 4
01 4.2
01 2
01 G 01 H 01 J 01 K 01 L 01 M01 F01 C01 D01 A01 A.4
M.1 01 E
01 1
01 8
01 10
01 9
01 7
01 9.6
01 1.4
01 3
01 5
01 6
01 6.3
01 8.2
CLEAN
2B120
COMM
CENTER
2B118
CONSULT
2C126
NOUR
2C108
TR
2C114C
2C114B
RETHERM
2B101
CONSULT
2C124
HK
2B112
TR
2B123D
2B110A
STOR/EQUIP
2B103
CLEAN
2B155D
2B159
CHUTE
2B105
COMM
CENTER
2C104
MED ROOM
2B155B
SOILED
2B155E
2B161
SERVICE BAY
2B123
SERVICE BAY
2C114
OFF
PHY/CON/NRS
2C120
HOUSE STAFF
2B104
PHARMACIST
2C118
ST
2C119
SOC WRK
2C121
HK
2C122
SOC WRK
2C123
PHY/CON/NRS
2C112
STAFF
LOUNGE
2B102
STAFF
LOCKER
2B126
DIET
2C116
NOUR
2B122
HEAD NURSE
2C113
CARE
PROVIDER
2C111
STOR/EQUIP
2C103
HEAD NURSE
2B116
EC
2B153
NORM ELEC
2C114A
EMER ELEC
2C114B
NORM ELEC
2B123B
EMER ELEC
2B123A
SOILED
2C152B
2C152
CLEAN
2C106
EC
2C154
PATIENT
2B146
PATIENT NEG
2B143
PATIENT
2B145
PATIENT POS
2B165
PATIENT
2B151
PATIENT
2B152
PATIENT
2B157
PATIENT
2B159
PATIENT
2B161
PATIENT
2B163
PATIENT
2B164
PATIENT
2B144 PATIENT
2B148
PATIENT
2B150 PATIENT
2B154
PATIENT
2B156
PATIENT
2B158
PATIENT
2B160
PATIENT
2B162
PATIENT
2C145 PATIENT
2C151
PATIENT
2C147 PATIENT
2C157
PATIENT
2C159
PATIENT
2C161
PATIENT
2C163
PATIENT
2C155
PATIENT
2C149
PATIENT
2C160
PATIENT POS
2C165
PATIENT
2C141
PATIENT
2C144 PATIENT
2C146 PATIENT
2C148
PATIENT
2C150
PATIENT
2C153
PATIENT
2C156
PATIENT
2C158
PATIENT
2C164
PATIENT NEG
2C140
CONF/
REPORT
2B106
SUB-STATION
2B132H
SUB-STATION
2B130A
SUB-STATION
2B130C
SUB-STATION
2B130E
SUB-STATION
2B132D
SUB-STATION
2B132F
SUB-STATION
2C131GSUB-STATION
2C131C
SUB-STATION
2C131ESUB-STATION
2C131A
SUB-STATION
2C133A
SUB-STATION
2C133C
RESPITE
2B166
2B172
T
2C145A
T
2C162A T
2C160A
T
2C151A T
2C155A
T
2C157A
T
2C159A T
2C161A
T
2C163A
T
2C164A
T
2C149A
T
2C158A
T
2C156A
T
2C153A
T
2C148A T
2C146A
T
2C144A
ISO T
2C142A
ISO T
2C140A
T
2C143A
T
2C147A
T
2B146A
T
2B140A T
2B142A
T
2B147A T
2B145A
T
2B149A
T
2B151A
T
2B152A
T
2B159A
T
2B161A
T
2B163A
ISO T
2B165A
ISO T
2B141A
T
2B164A
T
2B162A T
2B160A
T
2B158AT
2B156A
T
2B154A
T
2B150A T
2B148A
T
2B144A
ISO T
2B143A
MALE
2C101B
ANTE POS
2C165B
X-RAY
2C105
X-RAY ALC
2B115
HC ST
2B126A
TYP T
2B167
ANTE POS
2B165B
PATIENT NEG
2B141
PATIENT
2B142
PATIENT
(BAR)
2B140
PATIENT
2B147
PATIENT
2B149
PATIENT NEG
2C142 PATIENT
2C162
ISO T
2C165A
PATIENT
2C143
T
2C141A
PUB ELEV
LOBBY
2B100
SERV ELEV
LOBBY
2B107
SUPPLY
2C131D
ST
2B125
T
2C167
FEMALE
2C101A
RESPITE
2C166
2C172
CARE
PROVIDER
2B114
CORR
2B-C01A
CORR
2B-C01
CORR
2B-C04
CORR
2B-C02
CORR
2B-C03
AISLE
2B-C03A
CORR
2C-C03
CORR
2C-C04
CORR
2B-C01B
CORR
2B-C05
ELEV
BS-1
FUTURE ELEV
BS-2
ELEV
BS-4
ELEV
BS-3
STAIR
STB-1
SHAFT
SHB01
SHAFT
SHB03
SHAFT
SHC06
SHAFT
SHC05B
SHAFT
SHC05A
SUB-STATION
2C133E
CC
2C105A
CC
2C165C
CC
2B165C
ON CALL
2B129
ON CALL
2B131
PC1
2C115
CLEAN
2C152C
2C154
MED ROOM
2C152ESTAIR
STC-4
STAIR
STC-3
SECURITY
2C114D
SECURITY
2B123C
PC1
2C109
SUB-STATION
2B132B
CORR
2B-C04B
HC T/S
2B129A
CLST
2B129B
CLST
2B131A T/S
2B131B
ALCOVE
2C-C03B
T
2B157A
SUPPLY
2B132A
CORR
2C-C05
SHAFT
SHC05C
WAITING
2A100A
TR
2B155C
TR
2C152G
ELEV
BP-5
ELEV
BP-6
ELEV
BP-7
AISLE
BP-8
TR
2C152A
TR
2B155F
NURISHMENT
STATION
2B132C
01-MJ-022
01-MJ-024
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP 629-22-700
LOCATION
''1
10% BASIS OF DESIGN 07.08.2022 CONSULTANT
CONSULTANT: A/E:
GDM
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
04-25-2023
FULLY
SPRINKLED
GDM
1584 MCNEIL ST, SUITE 200
DUPONT, WA 98327
P: 360.318.7095
JESSE BARKSDALE, LEED-AP, CPD
WWW.GDM-AE.COM
35% SCHEMATIC DESIGN 11.10.2022
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
65% DESIGN DEVELOPMENT 01.13.2023
03.17.202395% CONSTRUCTION DOCUMENTS
04.25.2023100% CONSTRUCTION DOCUMENTS
04-25-2023
A u to d e s k D o c s /2
-0
N e w
O rl e a n s
E H
R M
/2 -0
N e w O rl e a n s E
H R
M
M e c h
.r v t
01-MH-021
SECOND FLOOR HVAC PLAN - BUILDINGS B
AND C
JB KT
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% CONSTRUCTION
DOCUMENTS
3/32" = 1'-0"1
SECOND FLOOR HVAC PLAN BUILDINGS B & C
KEY PLAN
D
E
F
G
K
H
J1 J2
M3 M1 M2
N1 N2
P
Q B1 B2
C1 C2
NORTH
DN
UP
DN
DN
DN
UP
UP
01-MJ-032
01-MJ-032
01-MJ-034
01-MJ-034
01-MJ-031
01-MJ-031
01-MJ-033
01-MJ-033
01 B
01 9.2
01 4
01 4.2
01 2
01 G 01 H 01 J 01 K 01 L 01 M01 F01 C01 D01 A01 A.4
M.1 01 E
01 1
01 8
01 10
01 9
01 7
01 9.6
01 1.4
01 3
01 5
01 6
01 6.3
01 8.2
BLOOD GAS
LAB
3C120
COMM
CENTER
3C103
CONSULT
3C124
TR
3C114C
3C114B
CHUTE
3B105
COMM
CENTER
3B118
HOUSE STAFF
3B104
HEAD NURSE
3C112
SOC WRK
3C121
SOC WRK
3C123
PHYS/CON/
NRS
3C110
STAFF
LOCKER
3B126
DIET
3C116
CARE
PROVIDER
3B114
HEAD NURSE
3B116
PHARMACIST
3C118
NOUR
3B122
TR
3B123D
3B110A
STOR/EQUIP
3B103
SERVICE BAY
3B123
SERVICE BAY
3C114
RETHERM
3B101
NORM ELEC
3B123B
EMER ELEC
3B123A
EMER ELEC
3C114B
NORM ELEC
3C114A
SOILED
3C152B
3C152
CLEAN
3B120
FEMALE
3C101A
X-RAY ALC
3C104
PHYS/CON/
NRS
3C122
STOR/EQUIP
3C102
MALE
3C101B
X-RAY ALC
3B115
PATIENT NEG
3B141 PATIENT NEG
3B143
PATIENT
3B145
PATIENT
3B147
ISO T
3B165A
T
3B163A
T
3B161A
T
3B159A
PATIENT
3B149
T
3B157A
T
3B152A
PATIENT
3B151
PATIENT
3B140
PATIENT
3B142
PATIENT
3B144
PATIENT
3B146
PATIENT POS
3B165
T
3B164A
T
3B160AT
3B158A
T
3B156A
T
3B162A
PATIENT
3B148
PATIENT
3B150
T
3B154A
T
3B151A
PATIENT
3B152
T
3B149A
T
3B147A T
3B145A
ISO T
3B141A
ISO T
3B143A
PATIENT
3B157
PATIENT
3B159
PATIENT
3B161
PATIENT
3B163
PATIENT
3B164
PATIENT
3B154
PATIENT
3B156
PATIENT
3B158
PATIENT
3B160
PATIENT
3B162
T
3B150A
T
3B148A T
3B146A
T
3B144A
T
3B142A
T
3B140A
EC
3C154
SUB-STATION
3B130A SUPPLY
3B130B
SUB-STATION
3B130C
SUPPLY
3B130D
SUB-STATION
3B130E SUB-STATION
3B132D
SUPPLY
3B132E
RESPITE
3B166
3B172
SERV ELEV
LOBBY
3B107
PUB ELEV
LOBBY
3B100
HK
3B112
NOUR
3C108
CLEAN
3C106
SOILED
3B155E
3B161
EC
3B153
SUB-STATION
3C131A
SUB-STATION
3C131C
SUB-STATION
3C131E
SUB-STATION
3C133A
SUB-STATION
3C133C SUB-STATION
3C133E
T
3C163A
ISO T
3C140A
ISO T
3C142A T
3C144A
T
3C146A
PATIENT
3C146
T
3C148A
PATIENT
3C148
PATIENT
3C150
T
3C150A
PATIENT
3C153
T
3C153A
T
3C156A
PATIENT
3C156
PATIENT
3C158
T
3C158A
T
3C162A
PATIENT
3C160
T
3C160A
T
3C141A
ISO T
3C165A
PATIENT
3C162
PATIENT
3C164
PATIENT
3C163
PATIENT
3C161PATIENT
3C159
PATIENT
3C157
SUPPLY
3C131D
SUPPLY
3C133B
RESPITE
3C166
3C172
T
3C164A
T
3C159A
T
3C161A T
3C157A
T
3C155A T
3C151A
T
3C149A
T
3C147A
T
3C145A T
3C143A
PATIENT NEG
3C140
PATIENT NEG
3C142
PATIENT
3C155
PATIENT
3C151
PATIENT
3C149
PATIENT
3C147
PATIENT
3C145
PATIENT
3C143
PATIENT
3C141
PATIENT POS
3C165
ANTE POS
3C165B
STAFF
LOUNGE
3B102
ST
3B124
T
3B167
T
3C167
ANTE POS
3B165B
HC ST
3B126A
AISLE
3B-C01A
CORR
3B-C01
CORR
3B-C01B
CORR
3B-C02
CORR
3B-C05
CORR
3B-C03
CORR
3C-C03
CORR
3C-C04A
CORR
3C-C02
ELEV
BS-1
FUTURE ELEV
BS-2
ELEV
BS-4
ELEV
BS-3
STAIR
STB-1
SHAFT
SHB01
SHAFT
SHB03
SHAFT
SHC06
SHAFT
SHC05B
SHAFT
SHC05A
SUPPLY
3B132A
SUPPLY
3C133D
TR
3B161A
CC
3B130H
TR
3C152A
CC
3C109
HK
3C125
CC
3C165C
CC
3B165C
ST
3B227
CARE
PROVIDER
3C230
CLEAN
3B155D
3B159
MED ROOM
3B155B
AISLE
3B-C03A
CLEAN
3C152C
3C154
MED ROOM
3C152E
AISLE
3C-C02A
STAIR
STC-4
STAIR
STC-3
SECURITY
3C114D
SECURITY
3B123C
UNASSIGNED
3C117
PATIENT
3C144
CORR
3B-C04B
SUB-STATION
3B132B
SUB-STATION
3C131G
AISLE
3B-C04A
ALCOVE
3C-C03B
ALCOVE
3B-C02A
OFF PCI
3B131
HC ON CALL
3B129
HC T/S
3B129A
PHYS/CON/NRS
3B130
CLST
3B129B
CONSULT
3C126
SUPPLY
3C131H
SHAFT
SHC05C
CORR
3C-C06
WAITING
3A100A
TEL CLST
3B155C
TEL CLST
3C152D
CONF/
REPORT
1C190C
NURISHMENT
STATION
3C131F
NURISHMENT
STATION
3B132C
2" CHR
2" CHS
2" CHR
2" CHS
01-MJ-034
01-MJ-032
2" EXPANSION LOOPS
WITH +/- 4" MOVEMENT
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP 629-22-700
LOCATION
''1
10% BASIS OF DESIGN 07.08.2022 CONSULTANT
CONSULTANT: A/E:
GDM
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
04-25-2023
FULLY
SPRINKLED
GDM
1584 MCNEIL ST, SUITE 200
DUPONT, WA 98327
P: 360.318.7095
JESSE BARKSDALE, LEED-AP, CPD
WWW.GDM-AE.COM
35% SCHEMATIC DESIGN 11.10.2022
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
65% DESIGN DEVELOPMENT 01.13.2023
03.17.202395% CONSTRUCTION DOCUMENTS
04.25.2023100% CONSTRUCTION DOCUMENTS
04-25-2023
A u to d e s k D o c s /2
-0
N e w
O rl e a n s
E H
R M
/2 -0
N e w O rl e a n s E
H R
M
M e c h
.r v t
01-MH-031
THIRD FLOOR HVAC PLAN - BUILDINGS B
AND C
JB KT
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% CONSTRUCTION
DOCUMENTS
3/32" = 1'-0"1
THIRD FLOOR HVAC PLAN BUILDINGS B & C
KEY PLAN
D
E
F
G
K
H
J1 J2
M3 M1 M2
N1 N2
P
Q B1 B2
C1 C2
NORTH
UPDN
DN
DN
UP
01-MJ-041
01-MJ-041
01-MJ-041
01-MJ-041
01-MJ-042
01-MJ-042
01 B
01 9.2
01 4
01 4.2
01 2
01 G 01 H 01 J 01 K 01 L 01 M01 F01 C 01 D01 A01 A.4
M.1 01 E
01 E
01 1
01 8
01 10
01 9
01 7
01 9.6
01 1.4
01 3
01 5
01 6
01 6.3
01 8.2
SERVICE BAY
4B123
SERVICE BAY
4C114
CONSULT
4B105
NOUR
4B122
TR
4B123D
4B114A
RETHERM
4B121
CHUTE
4B104
COMM
CENTER
4B118
STAFF
LOUNGE
4B109
CONF/
REPORT
4B106
HOUSE STAFF
4B107
RESIDENT
CONF
4B108
PCI
4B102
SOC WRK
4B110
CLEAN
4B155D
4B159
DIET
4B125
HEAD NURSE
4B114
CARE
PROVIDER
4B116
WAITING
4A100A
STOR/EQUIP
4B103
HC ST
4B126A
STAFF
LOCKER
4B126
EC
4B153
TR
4C114C
4C132B
NORM ELEC
4B123B
EMER ELEC
4B123A
EMER ELEC
4C114B
NORM ELEC
4C114A
PATIENT NEG
4B143
MED ROOM
4B155B
SOILED
4B155E
4B161
CLEAN
4B120
ISO T
4B141A
ISO T
4B143A
PATIENT
4B163
T
4B145A
PATIENT
4B161
T
4B147A
PATIENT
4B159
T
4B149A
PATIENT
4B157
T
4B151A
PATIENT
4B152
T
4B140A
PATIENT
4B164
T
4B142A
PATIENT
4B162
T
4B144A
PATIENT
4B160
T
4B146A T
4B148A
PATIENT
4B158
T
4B150A
PATIENT
4B156
T
4B154A
PATIENT
4B154
T
4B156A
PATIENT
4B151
T
4B158A
PATIENT
4B149
T
4B160A
PATIENT
4B147
T
4B162A
PATIENT
4B145
T
4B164A
PATIENT
4B142
PATIENT
4B140
T
4B163A
PATIENT
4B150
T
4B161A
PATIENT
4B148
T
4B159A
PATIENT
4B146
T
4B157A
PATIENT
4B144
T
4B152A
SUB-STATION
4B130A
SUB-STATION
4B130C
SUB-STATION
4B130E
SUB-STATION
4B132H