2.6 - Drawings 06 of 17 - 03-AC-011 to 11-AE-011.pdf
PDF 21 MB Posted
- Solicitation number
- 36C77623B0038
About this file
This document provides details on a federal contract opportunity for infrastructure upgrades at a Veterans Affairs facility in New Orleans, Louisiana. The solicitation number is 36C77623B0038 and is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin. It is seeking construction services for NOLA EHRM Infrastructure Upgrades at the New Orleans location, as outlined in 21MB of drawings contained in an attached file. The opportunity type is listed as a solicitation. No further information is provided on response dates, pricing terms, or set-asides in the pre-solicitation documentation.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C L
CL
C L
CL
C L
C LCL
CL C L
FDFD
AP
AP
KEY PLAN
NORTH
GENERAL NOTES ARCHITECTURAL
A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY
TO ADD OR REMOVE CABLES WITHOUT RESEALING.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE
EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.
GENERAL NOTES REFLECTED CEILING
A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL SHEET NOTES
GYP. BD. CEILING SYSTEM
2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.
DOWN LIGHT FIXTURE
LEGEND
KEYED NOTES
1'X4' LIGHT FIXTURE
8' X 7" LIGHT FIXTURE
2'X4' LIGHT FIXTURE
2'X2' SUPPLY
2'X2' RETURN
T SPEC
1H109
MAS: RECEPT
1H102
TECH/ CLEAN
1H108
EXAM
1H112
EXAM
1H111
INTV
1H206
BLOOD DRAW
1H116
BLOOD DRAW
1H120
BLOOD DRAW
1H117
BLOOD DRAW
1H119
BLOOD DRAW
1H118
CHIEF
1H214
INTV
1H201
INTV
1H208
INTV
1H200
T SPEC
1H110
ST
1H210
T SPEC
1J226
INTV
1J110D
OFF COUNSEL
1J252
EXAM
1J230
GROUP THERAPY
1J124
STOR-SOC ACTIV
1J273
INTAKE
1J242
FAMILY WAITING
1J136
FAM COUNSEL
1J131
GROUP THERAPY
1J120
T 1J136A
FAM COUNSEL
1J132
FAM COUNSEL
1J130
GROUP THERAPY
1J122
GROUP THERAPY
1J118
RECEPT
1J110A
GROUP THERAPY
1J126
OFF COUNSEL
1J205
OFF COUNSEL
1J207
OFF COUNSEL
1J216
TELEMED
1J274
OFF COUNSEL
1J219
TECH
1J253A
HK
1J212
ST
1J275
RES OFF
1J307
RES OFF
1J315
RES OFF
1J314
TR
1J301B
RES OFF
1J312
OFF RES
1J310
PROG LDR
1J311
OFF COUNSEL
1J238
RES OFF
1J302RES OFF
1J304
OFF RES
1J309
OFF COUNSEL
1J268
OFF COUNSEL
1J241
OFF COUNSEL
1J248
OFF COUNSEL
1J239
OFF COUNSEL
1J249
OFF COUNSEL
1J218
OFF COUNSEL
1J267
OFF COUNSEL
1J264
OFF COUNSEL
1J206
OFF COUNSEL
1J204
ST
1J277
OFF COUNSEL
1J262
T SPEC
1J224
EXAM
1J228
INTAKE
1J225
GROUP THERAPY
1J227
OFF COUNSEL
1J233
SOILED
1J210
MEDS
1J231
COPY
1J215
OFF COUNSEL
1J232
OFF COUNSEL
1J250
TREAT
1J236
SERVICE BAY
1J299
SERVICE BAY
1J104
NORM ELEC
1J299B
EMER ELEC
1J299A
RES OFF
1J313
OFF COUNSEL
1J251
T 1J127
ST
1J214
ST
1J211
TRMT/ RELAX
1J200
HK
1J261
TYP BIOFDBK TRTMT
1J265
MULTI-PURPOSE
1J116
OFF COUNSEL
1J263
T 1J270
INTV
1H202
TR
1H211
NORM ELEC
1J104B
EMER ELEC
1J104A
TR
1J102A
FAM COUNSEL
1J129
PSA
1J110C
TELEMED
1J272
T 1J271
UNASSN
1J316
PTSD CLINIC: WAITING
1J112
SUBSTANCE ABUSE
CLINIC: WAITING
1J111
SOILED
1H114
LOBBY
1H100
WC
1J110H
FEMALE
1J103
MALE
1J101
T 1J128
STOR
1J208
SUPRV
1H213
PHLEB RECEPT
1H103
ELEC
1H113A
INTAKE
1J203
INTAKE
1J222
OFF COUNSEL
1J220
BIOFDBK TRTMT
1J209
OFF COUNSEL
1J221
INTAKE
1J223
OFF COUNSEL
1J217
INTAKE
1J243
OFF COUNSEL
1J244
OFF COUNSEL
1J246
OFF COUNSEL
1J237
UNASSN
1J235
OFF COUNSEL
1J247
OFF COUNSEL
1J245
OFF COUNSEL
1J266
OFF COUNSEL
1J269
UNASSN
1J276
CONF STAFF
1J305
RES OFF
1J303
ELIG CLERK
1H203
ELIG CLERK
1H204
WAITING
1H104
SERV ELEV LOBBY
1J105
STAIR
1J-STJ-3
VEST
1J100
STAIR
STJ-2
STAIR
STH-1
PSA
1J110B
WAITING
1H100A
CORR
1H-C05
CORR
1H-C06
CORR
1H-C07
CATER KIT
1J116A
CORR
1J-C02
CORR
1J-C03 CORR
1J-C04
CORR
1J-C05
CORR
1J-C01
AISLE
1J-C01C
AISLE
1J-C01A
CORR
1J-C09
CORR
1J-C06
CORR
1J-C07 CORR
1J-C08
CORR
1J-C10
SHAFT
SHJ04A
KIOSK
1J206F
EWC
1J206G
MENTAL HEALTH CLINIC:
WAITING
1J110
LVSR
1J102B
INTV
1J110E
AISLE
1J-C01B
CLEAN SUPPLY
1J234
INTV
1H209
INTV
1H207
INTV
1H205
HK
1H115
CORR
1H-C04
AISLE
1H-C08
TECH
1J253B
WC
1J110J
RES OFF
1J306
PSA(2)
1H212
LOW VOLT
1J301A
ALC
1H-C04A
WC
1H101
AISLE
1H-C05A AISLE
1H-C05B
UNASSIGNED
1H113B
WAITING
1H100B
OUTPATIENT STAIR
1H100C
CAFE
1J106
STORAGE
1J106A
CLOS
1J105.2
CLOS
1J100A
CAFE SERVING
1J106B
ELEV
JS-5
ELEV
JS-6
ELEV
JP-1
ELEV
JP-3
ELEV
JP-2
ELEV
JP-4
03-AJ-013
E1
03-AJ-013
E3
CIRC DESK
1H135
FILE/ WRK
1H136
ADMIN CUBS
1H137
PAT WELL COORD
1H139
CLASSRM
1H134
CLASSRM
1H132
CLASSRM
1H130
DEMO KIT
1H132A
COUNSEL
1H142
COUNSEL
1H141
PAT ED CUBS
1H140
READING AREA
1H138
CLOS
1H130A
CLOS
1H134A
ALC
1H132B
ALC
1H134C
CORR
1H-C02
EXAM
1H134B
EXAM
1H130B
CORR
1H-C01
BLOOD DRAW
1H116
BLOOD DRAW
1H120
BLOOD DRAW
1H117
BLOOD DRAW
1H119
BLOOD DRAW
1H118
CHIEF
1H214
TR
1H211
SOILED
1H114
SUPRV
1H213
CORR
1H-C05
CORR
1H-C06
HK
1H115
CORR
1H-C04
PSA(2)
1H212
ALC
1H-C04A
UNASSIGNED
1H113B
64' - 2 3/4"
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AC-011
H & J
LEVEL 1 REFLECTIVE CEILING PLAN
BUILDINGS H & J
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R H
O U
S E
3/32" = 1'-0"F2
FIRST FLOOR REFLECTIVE CEILING PLAN BUILDINGS H & J
3/32" = 1'-0"C5
FIRST FLOOR REFLECTIVE CEILING PLAN BUILDING H WING
NORTH
Revisions: Date:
C L
CL
C L
C LCL
CL C L
FD
KEY PLAN
NORTH
GENERAL NOTES ARCHITECTURAL
A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY
TO ADD OR REMOVE CABLES WITHOUT RESEALING.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE
EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.
GENERAL NOTES REFLECTED CEILING
A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL SHEET NOTES
GYP. BD. CEILING SYSTEM
2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.
DOWN LIGHT FIXTURE
LEGEND
KEYED NOTES
1'X4' LIGHT FIXTURE
8' X 7" LIGHT FIXTURE
2'X4' LIGHT FIXTURE
2'X2' SUPPLY
2'X2' RETURN
EXAM
2H112
EXAM
2H110
EXAM
2H111
RECEPT
2H101
PSA MGR
2H120
EXAM
2H113
EXAM
2H109
EXAM
2H106
CLEAN SUPPLY
2H119
EXAM
2H108
COPY/ STOR
2H103
PHY MGR
2H116
NS STN
2H114
CONSULT
2H118
PROVID
2H117
CLERKS
2H102
ELEC
2H200A
ST
2H130
ST
2H128
INVENTORY CNTRL
2J200F
STAFF LOUNGE
2J317
INVESTIG DRUGS
2J214
SUPRV
2J212
CONF
2J315
OFF
2J210
CONSULT
2J118
CONSULT
2J117
SERVICE BAY
2J104
RECEIVING
2J205
ST
2J211
CNTRL SUBST
2J201
FILLING AND
DISPENSING
2J200
NORM ELEC
2J104B
EMER ELEC
2J104A
TR
2J102A
DISPENSING
2J116
MAIL OUT
2J200D
REF/FR
2J200B
PROSTH SUPPLY
2J200G
FILLING
2J200C
PHARMACY: WAITING
2J110A
MALE
2J101
FEMALE
2J103
RECEIVING
2J119
EXAM
2J255
EXAM
2J248
EXAM
2J251
EXAM
2J250
CLEAN/ MED
2J262
EXAM
2J222
EXAM
2J249
I-GLASS FITTING/
DISPLAY
2J254B
VIS FIELD EXAM
2J238
PRE-TEST
2J244
PRE-TEST
2J246
PRE-TEST
2J247
TYP PRE-TEST
2J245
IVFA
2J257
SUB-WAIT
2J220
EXAM
2H107
EXAM
2J223
SPEC EXAM
2J229
SOILED
2J281
EXAM
2J226
EXAM
2J227
EYE PROCED
2J280
IVFA/ PENTACAM
2J259
IVFA/ PENTACAM
2J263
DILATION SUB-WAIT
2J292
U-S/OCT
2J258
ELECTRO DX
2J256
YAG LASER
2J275
LOW VOLT
2J300A
PROVID/ VIST
2J311
LOW V TRAINING
2J232
CONSULT/ VIST
2J310
CHIEF
2J307
SPEC EXAM
2J237
CONF
2J114
ST
2J283
TYP LOUNGE
2J308
EXCIMER LASER
2J276
T 2J290
EXAM
2J221
LOW V EXAM
2J230
T 2J112
VIS FIELD EXAM
2J239
PAT ED/CONTACT LENS
2J254A
ADMIN
2J312
WORK
2J291
EYE CLINIC: WAITING
2J111
WORKSPACE
2J240
STOR
2J279
ARGON LASER
2J277
WORKSPACE
2J241
ST
2J208
ADMIN
2J264
ADMIN
2J265
SOILED
2J204
HK
2J203
VAULT
2J202
HK
2J282
NORM ELEC
2J299B
EMER ELEC
2J299A
SERVICE BAY
2J299
ANTE
2J207
COPY
2J235
PROVIDERS
2J305
NUR MGR
2J314
SOCIAL WORK
2J313 BROS
2J309
CLEAN
2J294
RECEPT
2J111A
INTV
2J111C
WC
2J111B
INTV
2J111D
EXAM
2J224
EXAM
2J252
SPEC EXAM
2J236
SERVICE BAY
2H200
T 2H105
CONF
2H124
CASHIER
2H127
PAT FUNDS
2H129
TRAVEL CLERK
2H126
PHONE BANK
2J206
ORDER ENTRY
2J209
UNASSN
2H123
UNASSN
2H122
UNASSN
2H121
UNASSN
2H115
SERV ELEV LOBBY
2J105
PUB ELEV LOBBY
2J100
AISLE
2H-C01
AISLE
2H-C02
CORR
2H-C06
CORR
2H-C04
CORR
2H-C08
CORR
2H-C03
CORR
2H-C05
CORR
2H-C07
KIOSK
2J113
ALC
2J225
ALC
2J240A
ALC
2J243
ALC
2J260
CORR
2J-C06
CORR
2J-C01
CORR
2J-C04
CORR
2J-C05
CORR
2J-C07 CORR
2J-C08
CORR
2J-C09
AISLE
2J-C04AAISLE
2J-C04B
AISLE
2J-C07A
AISLE
2J-C07B
AISLE
2J-C08A
CUST SERV
2J115
UNASSN
2J316
EXTEMP CMPD
2J200E
WAITING
2H100A
LVSR
2J102B
LOW V STOR
2J230A
CONSULT/ VIEW
2J234
WORKSPACE
2J242
ALC
2J262A
ALC
2J278
COPY
2J213A
STOR
2J213
ANTE
2J115A
HK
2H201
EXAM
2J228
STAIR
STH-2
FILLING AND
DISPENSING
2J200A
PHARMACY: WAITING
2J110B
WAITING DISPOSITION
2H100B
STAIR
2J-STJ-3
AISLE
2J-C10
LVSR
2H200B
TR
2H200C
TR
2J300B
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AC-021
H & J
LEVEL 2 REFLECTIVE CEILING PLAN
BUILDINGS H & J
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R H
O U
S E
3/32" = 1'-0"F1
SECOND FLOOR REFLECTIVE CEILING PLAN BUILDINGS H & J
C L
CL
C L
C LCL
CL C L
KEY PLAN
NORTH
GENERAL NOTES ARCHITECTURAL
A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY
TO ADD OR REMOVE CABLES WITHOUT RESEALING.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE
EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.
GENERAL NOTES REFLECTED CEILING
A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL SHEET NOTES
GYP. BD. CEILING SYSTEM
2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.
DOWN LIGHT FIXTURE
LEGEND
KEYED NOTES
1'X4' LIGHT FIXTURE
8' X 7" LIGHT FIXTURE
2'X4' LIGHT FIXTURE
2'X2' SUPPLY
2'X2' RETURN
SHARED CONF
3J125
SEC
3J311
TELE-MED
3J316
PROV/RES/STUDENT
3J315
EXAM
3J254
EXAM
3J256
EXAM
3J283
EXAM
3J276
EXAM
3J252
T 3J237A
PROCED (LEAD)
3J260
PROCED (LEAD)
3J237
GU URINE
3J239
T 3J239A
T 3J260A
SERVICE BAY
3J299
SERVICE BAY
3J104
NORM ELEC
3J299B
NORM ELEC
3J104B
EMER ELEC
3J104A
TR
3J102A
EMER ELEC
3J299A
PAT EXAM
3J250
INTV
3J110C
ISO EXAM
3J206
ISO T
3J206A
EXAM
3J203
T 3J130
CLEAN/ EQUIP
3J215
ST
3J211
TRIAGE
3J229
SPEC EXAM (LEAD)
3J236
CLEAN/ MED
3J208
ST
3J214
EXAM
3J223
PAT EXAM
3J248
EXAM
3J224
EXAM
3J226
EXAM
3J201
PAT EXAM
3J249
EXAM
3J205
EXAM
3J222
SPEC EXAM
3J209
SPEC EXAM
3J216
WORKSPACE
3J218
INTV
3J110D
RECEPT
3J110A
WC
3J110B
EXAM
3J230
ALC
3J235
TRIAGE
3J225
STAFF LOUNGE/
LOCKERS
3J317
WORK
3J122
HK
3J213
SOILED
3J210
EXAM
3J221
EXAM
3J232
EXAM
3J228
SPEC EXAM
3J217
EXAM
3J280
EXAM
3J278
EXAM
3J279
CONF
3J301
TRIAGE
3J253
TRIAGE
3J275
EXAM
3J272
SPEC EXAM
3J267
CLEAN/ EQUIP
3J264
EXAM
3J281
ISO EXAM
3J285
ISO T
3J285A
CLEAN/MED
3J287
T 3J116
CONSULT
3J113INTV
3J111C
INTV
3J111D
RECEPT
3J111A
WC
3J111B
T 3J126
TR
3J300B
T 3J120
COPY
3J124
ADVOCATE
3J115
WORK
3J245
TELE-MED
3J308
MOD A CONF
3J309
RN MGR
3J123
CLINIC MGR
3J310
SEC
3J262
ADM ASST
3J243
WORKSPACE
3J268
CONSULT
3J132 ITAC
3J114
PROV/RES/STUDENT
3J307
PROCED
3J112
ALC
3J258
MODULE A: WAITING
3J110
MODULE D: WAITING
3J111
MALE
3J101
SUPPLY/ EQUIP
3J244
FEMALE
3J103
KIOSK
3J131
KIOSK
3J121
WORKSPACE
3J269
PHARM
3J242
WORKSPACE
3J219
OFF CHIEF (RT)
3H113
COPY/ STOR
3H134
OFF COORD
3H109
OFF COORD
3H108
ADMIN
3H141A
OFF COORD
3H107
PHYS OFF
3H110
OFF CHIEF (PULM)
3H112
PM & MSA: CONF
3H130
CLER
3H136
CLER
3H138C
CLER
3H138D
OFF ITAC
3H114A
OFF ADMIN
3H116 OFF CHF SERV
3H114
OFF ASST CHF
3H115
OFF ST PHYS
3H120
OFF ST PHYS
3H121OFF ST PHYS
3H122 OFF ST PHYS
3H119
OFF ST PHYS
3H118
OFF CHF RES
3H138B
COPY/ STOR
3H133
CLER
3H138A
ELEC
3H123
EWC
3J127
EWC
3J117
EXAM
3J231
EXAM
3J233
PAT EXAM
3J247
EXAM
3J274
EXAM
3J255
EXAM
3J257
SPEC EXAM
3J286
SPEC EXAM
3J266
SPEC EXAM
3J259
ALC
3J288
EXAM
3J273
EXAM
3J271
EXAM
3J282
HK
3H125
UNASSN
3H106
EXAM
3J202
EXAM
3J204
EXAM
3J200
CAST CUBICLE C
3J245C
PUB ELEV LOBBY
3J100
SERV ELEV LOBBY
3J105
ALC
3J207
ALC
3J220
ALC
3J234
TYP CAST CUBICLE B
3J245B
CAST CUBICLE A
3J245A ALC
3J270A ALC
3J284
AISLE
3H-C01A
AISLE
3H-C03
AISLE
3H-C04
CORR
3H-C02
AISLE
3J-CO1A
AISLE
3J-CO1B
AISLE
3J-CO1C
AISLE
3J-CO1D
CORR
3J-C01
CORR
3J-C02
CORR
3J-C03
CORR
3J-C04
CORR
3J-C05
CORR
3J-C06
CORR
3J-C07
CORR
3J-C08
CORR
3J-C09
AISLE
3J-CO4A
AISLE
3J-CO6B
CORR
3H-C06
CORR
3H-C05
CORR
3H-C01
CC
3J270B
LVSR
3J102B
TRAINING/WRKRM
3H140
SEC/WAIT
3H138E
OFF ST PHYS
3H117
FILE
3H135
SEC/WAIT
3H100
SW SOC WRKR
3H101
SW EQUIP STOR
3H105
SW CHIEF
3H104
SW SUPER
3H103
SW SUPER
3H102
HK
3J265
AISLE
3H-C05A
ALC
3J247A
T 3J112A
STAIR
3J-STJ-3
LOW VOLT
3J300A
ST
3H126
ST
3H124 SHAFT
SHH01
AISLE
3J-C04B
CLOS
1J100A
CAFE SERVING
1J106B
ELEV
JS-5
ELEV
JS-6
ELEV
JP-1
ELEV
JP-3
ELEV
JP-2
ELEV
JP-4
SHAFT
SHJ01
SHAFT
SHJ02
03-AJ-033
F1
03-AJ-033
F3
TR
3H130A
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AC-031
H & J
LEVEL 3 REFLECTIVE CEILING PLAN
BUILDINGS H & J
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R H
O U
S E
3/32" = 1'-0"F1
THIRD FLOOR REFLECTIVE CEILING PLAN BUILDINGS H & J
C LCL
KEY PLAN
NORTH
GENERAL NOTES ARCHITECTURAL
A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY
TO ADD OR REMOVE CABLES WITHOUT RESEALING.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE
EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.
GENERAL NOTES REFLECTED CEILING
A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL SHEET NOTES
GYP. BD. CEILING SYSTEM
2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.
DOWN LIGHT FIXTURE
LEGEND
KEYED NOTES
1'X4' LIGHT FIXTURE
8' X 7" LIGHT FIXTURE
2'X4' LIGHT FIXTURE
2'X2' SUPPLY
2'X2' RETURN
T 4J274
MAX-FAC
4J447
ORAL SURG/RECOVERY
4J443
ORAL SURG
4J445
ORAL SURG RES
4J441
ORAL SURG
4J449
HYGIENE
4J277
COLOR MATCH
4J271
SURG STOR/MEDS
4J286
LINEN/ SPD CARTS
4J290
CHIEF
4J301
DENTAL TRTMT
4J255
DENTAL TRTMT
4J272
DENTAL TRTMT
4J268
DENTAL TRTMT
4J248
DENTAL TRTMT
4J243
DENTAL TRTMT
4J256
DENTAL TRTMT
4J250
DENTAL TRTMT
4J258
DENTAL TRTMT
4J254
DENTAL TRTMT
4J251
DENTAL TRTMT
4J249
DENTAL TRTMT
4J263
DENTAL TRTMT
4J240
DENTAL TRTMT
4J242
DENTAL TRTMT
4J244
DENTAL TRTMT
4J247
LOUNGE
4J304
PAN-X
4J261
INTV
4J111CINTV
4J111D
RECEPT
4J111A
T 4J112
ADMIN
4J303
SOIL SPD CART
HOLDING
4J292
ASST CHIEF
4J302
DENTAL CLINIC:
WAITING
4J111
PAN-X
4J276
TR
4J300B
CERAMIC LAB
4J293
PHYS/ PROV/ STUDENT
4J308SEC
4J310
EXAM
4J222
EXAM
4J228
EXAM
4J200
EXAM
4J202
SPEC EXAM
4J217
WORKSPACE
4J218
MOD E CONF
4J311
HK
4J213
TRIAGE
4J225
RECEPT
4J110A
ST
4J214
GASTRIC MOTILITY
4J237
DIR
4J309
HC ST
4J267A
GEN PROCED
4J235
SERVICE BAY
4J104
SOILED
4J210
CLEAN SUPPLY
4J215
SPEC EXAM
4J209
SPEC EXAM
4J216
EXAM
4J226
TRIAGE
4J229
EXAM
4J204
EXAM
4J201
UA LAB
4J124
T 4J122 T
4J118
SHARED MP CONF
4J114
WC
4J110B
INTV
4J110C
INTV
4J110D
CLEAN/ MED
4J208
NORM ELEC
4J104B
EMER ELEC
4J104A
TR
4J102A
T 4J237A
ISO EXAM
4J206
ISO T
4J206A
SHARED COPY
4J115
EXAM
4J116
MODULE E: WAITING
4J110
MALE
4J101
FEMALE
4J103
RES/ PROV/ STUDENT
4J315
KIOSK
4J123
STAFF LKR
4J267
EXAM
4J117
WORKSPACE
4J219
SERVICE BAY
4J299
NORM ELEC
4J299B
EMER ELEC
4J299A
HC ST
4J294A
HYGIENE
4J275
DENTAL/ PROS LAB
4J291
STAFF LKR
4J294
ST
4J288
DENTAL TRTMT
4J273
DENTAL STOR
4J245
RES CONF
4J266
STAFF LOUNGE
4J317
ST
4J211
WC
4J111B
EWC
4J119
KIOSK
4J113
SPEC EXAM
4J236
ORAL SURG OFF
4J287
DENTAL ASST
4J295
EXAM
4J203
EXAM
4J205
EXAM
4J224
EXAM
4J223
EXAM
4J221
EXAM
4J232
EXAM
4J230
EXAM
4J231
EXAM
4J233
DENTAL TRTMT
4J246
DENTAL TRTMT
4J260
DENTAL TRTMT
4J262
DENTAL TRTMT
4J241
DENTAL TRTMT
4J257
DENTAL TRTMT
4J270
DENTAL TRTMT
4J259
SOILED
4J269
OFF
4H105
OFF
4H104
ASSIST CHIEF
4H109
CONF
4H130
OFF
4H118
OFF
4H103
OFF
4H106
ACOS AMB CARE
4H111
OFF
4H119
OFF
4H116
OFF
4H121
DERM OFF
4H122
CUB
4H134C
CUB
4H134E
CUB
4H134D
CUB
4H134BCUB
4H134A
CUB
4H133C
CUB
4H133E
CUB
4H133D CUB
4H134F
OFF
4H107
OFF
4H117
OFF
4H120
COPY/ STOR
4H114
ELEC
4H125
TR
4H113
ASST CHIEF
4H123
MH COPY/ WORK
4H108
MHS CHIEF
4H100
MH SOCIAL WORK
4H124
ITAC ANALYST
4H102
HSS OFFICER
4H101
PSA-1
4H132A
PSA-2
4H132B
PSA-3
4H132D
PSA-4
4H132C
STOR
4J289
SERV ELEV LOBBY
4J105
ALC
4J207
ALC
4J220
ALC
4J234
CORR
4J-C01
AISLE
4J-CO1A
AISLE
4J-CO1B
AISLE
4J-CO1CAISLE
4J-CO1D
CORR
4J-C02
CORR
4J-C03
CORR
4J-C04
CORR
4J-C05
CORR
4J-C06
CORR
4J-C07
CORR
4J-C08
CORR
4J-C09
CORR
4J-C010
CORR
4J-C011
PUB ELEV LOBBY
4J100
AISLE
4J-CO6A
AISLE
4J-CO7A
AISLE
4J-CO5A
CC
4J235B
AISLE
4H-C03
CORR
4H-C02
AISLE
4H-C06A
AISLE
4H-C05
CORR
4H-C05A
CORR
4H-C01
CORR
4H-C06
LVSR
4J102B
DIRTY LAB
4J291A
AISLE
4H-C01A
HK
4H127
MED GAS MANIFOLD
4J297
CORR
4J-CO13HK
4J264
STAIR
4J-STJ-3
LOW VOLT
4J300A
ST
4H128
ST
4H126
SHAFT
SHH02
UNASSN
4H130A
CUB
2J279B
CUB
2J279C
CUB
2J279D
03-AJ-043
F4
03-AJ-043
F1
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AC-041
H & J
LEVEL 4 REFLECTIVE CEILING PLAN
BUILDINGS H & J
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R H
O U
S E
3/32" = 1'-0"E1
FOURTH FLOOR REFLECTIVE CEILING PLAN BUILDINGS H & J
C LCL
KEY PLAN
NORTH
GENERAL NOTES ARCHITECTURAL
A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY
TO ADD OR REMOVE CABLES WITHOUT RESEALING.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE
EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.
GENERAL NOTES REFLECTED CEILING
A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL SHEET NOTES
GYP. BD. CEILING SYSTEM
2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.
DOWN LIGHT FIXTURE
LEGEND
KEYED NOTES
1'X4' LIGHT FIXTURE
8' X 7" LIGHT FIXTURE
2'X4' LIGHT FIXTURE
2'X2' SUPPLY
2'X2' RETURN
EXAM
5J224
EXAM
5J226
ISO EXAM
5J206
SPEC EXAM
5J215
CHIEF
5J301
EXAM
5J200
EXAM
5J202
ST
5J214
SOILED
5J210
SPEC EXAM
5J216
TRIAGE
5J225
EXAM
5J233
EXAM
5J231
EXAM
5J230
EXAM
5J205
EXAM
5J201
CLEAN/ MED
5J208
T 5J122
TELE-MED
5J316
CALIB/ STOR
5J241
AUDIO SUITE 4
5J248
AUDIO SUITE 3
5J246
AUDIO SUITE 2
5J244
AUDIO SUITE 1
5J242
AUDIO SUITE 5
5J250
HEARING- AID LAB
5J243
FITTING/ EXAM
5J111T
TYP CERUMEN MGT
5J265
ROTARY CHAIR
5J260
TYP AUDIO TECH
5J263
AUDIO SUITE 6A
5J251A
AUDIO SUITE 7A
5J253A AUDIO SUITE 8A
5J255A
AUDIO SUITE 9A
5J262A
AUDIO TECH
5J261
AUDIO TECH
5J259
AUDIO THERAPY
5J286
AUDIO THERAPY
5J283
EQ STOR
5J258
AUD/SP LKR/LOUNGE
5J308
ADMIN ASST
5J303
DERM: PROCED
5J237
T 5J235A
SERVICE BAY
5J104
SHARED CONF
5J114
T 5J112
TYP EXAM
5J203
SHARED COPY
5J116
HK
5J212
DE:PHOTO THER
5J238
ISO T
5J206A
DE: LAB
5J311
AUDITORY REHAB
5J281
EXAM
5J204
TR
5J300B
CLER
5J304
AUDIO THERAPY
5J284
AUDIO THERAPY
5J285
AUDIO THERAPY
5J287
POSTUR
5J247
VESTIB
5J249
RECEPT
5J110A
MODULE C: WAITING
5J110
TR
5J102A
ST
5J256
T 5J118
CONSULT
5J124
INTV
5J110C
WC
5J110B
INTV
5J111C
WC
5J111B
WORKSPACE
5J282
GEN PROCED
5J235
AUDIOLOGY/SPEECH:
WAITING
5J111
FEMALE
5J103
MALE
5J101
WORKSPACE
5J218
STAFF LOUNGE
5J317
WORKSPACE
5J219
SERVICE BAY
5J299
NORM ELEC
5J299B
EMER ELEC
5J299A
SPD SOILED
5J209
HK
5J257
INTV
5J110D
INTV
5J111D
EXAM
5J228
DE: MED-PREP
5J239
MOD C CONF
5J309
TRIAGE
5J229
HC T/SHWR
5J238A
TYP EXAM
5J222
TYP EXAM
5J223
EXAM
5J221
EXAM
5J232
SPEC EXAM
5J207
SPEC EXAM
5J236
CLEAN/ EQUIP
5J240
PROVIDER, RESIDENT
WORK
5J315
AUD/SP WORK AREA
5J302
COPY
5J245
ALC
5J288
UNASSN
5J115
PUB ELEV LOBBY
5J100
KIOSK
5J123
EWC
5J117
KIOSK
5J113
CORR
5J-C02
CORR
5J-C01
CORR
5J-C03
CORR
5J-C04
ALC
5J207A
ALC
5J220
ALC
5J234
AUDIO SUITE 4A
5J248A
AUDIO SUITE 3A
5J246A
AUDIO SUITE 2A
5J244A
AUDIO SUITE 1A
5J242A
AUDIO SUITE 5A
5J250A
AUDIO SUITE 6
5J251
AUDIO SUITE 7
5J253
AUDIO SUITE 8
5J255
AUDIO SUITE 9
5J262
SERV ELEV LOBBY
5J105
CORR
5J-C05
CORR
5J-C06
CORR
5J-C08
CORR
5J-C010
CORR
5J-C011
AISLE
5J-CO6A
AISLE
5J-CO5A
AISLE
5J-CO5B
AISLE
5J-CO1A
AISLE
5J-CO1B
RECEPT
5J111A
TYP SPECIAL PROCED
5J111P
SPECIAL PROCED
5J111Q
SPEECH ANALYSIS
5J111L
T 5J111S
SPEECH GRP THERAPY
5J111R
CAT WKRM
5J111M
SPEECH PATH
5J111K
SPEECH THERAPY
5J111G
SPEECH THERAPY
5J111H
SPEECH THERAPY
5J111F
SPEECH PATH
5J111N
TYP SPEECH PATH
5J111J
CORR
5J-C07B
CORR
5J-C07C
CORR
5J-C07
LVSR
5J102B
HEARING AID CENTER
5J111E
VEST
5J111U
ELECTRO- PHYS
5J278
CERUMEN MGT
5J280
PATH LAB
5J312
CC
5J235B
STAIR
5J-STJ-3
LOW VOLT
5J300A
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AC-051
J
LEVEL 5 REFLECTIVE CEILING PLAN
BUILDING J
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R H
O U
S E
3/32" = 1'-0"F1
FIFTH FLOOR REFLECTIVE CEILING PLAN BUILDING J
KEY PLAN
NORTH
GENERAL NOTES ARCHITECTURAL
A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY
TO ADD OR REMOVE CABLES WITHOUT RESEALING.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE
EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.
GENERAL NOTES REFLECTED CEILING
A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL SHEET NOTES
GYP. BD. CEILING SYSTEM
2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.
DOWN LIGHT FIXTURE
LEGEND
KEYED NOTES
1'X4' LIGHT FIXTURE
8' X 7" LIGHT FIXTURE
2'X4' LIGHT FIXTURE
2'X2' SUPPLY
2'X2' RETURN
MODULE G: WAITING
6J110
MODULE H: WAITING
6J111
TYP EXAM
6J205
ISO EXAM
6J206
ISO T
6J206A
TYP SOILED
6J262
TYP T
6J130
CLEAN/ EQUIP
6J215
TYP TELE-MED
6J239
T 6J260A
T 6J120
T 6J126
ST
6J214
TR
6J300B
PROCED
6J237
SPEC EXAM
6J217
MH OFF
6J250
CONSULT
6J113
TELE- RETINAL
6J123
MH OFF
6J245
TYP CLEAN/ MED
6J208
EXAM
6J256
EXAM
6J279EXAM
6J269
EXAM
6J271
MH OFF
6J244
TRIAGE
6J251
TRIAGE
6J273
EXAM
6J277
SPEC EXAM
6J265
EXAM
6J255
EXAM
6J275
CLEAN/ MED
6J283
ST
6J211
TYP T
6J237A
EXAM
6J202
EXAM
6J232
EXAM
6J204
EXAM
6J200
EXAM
6J233
SPEC EXAM
6J236
TYP SPEC EXAM
6J216
SPEC EXAM
6J259
EXAM
6J274
PHARM
6J247
PHARM
6J249
WORKSPACE
6J267
TYP WC
6J110B
ISO EXAM
6J281
EXAM
6J226
WORKSPACE
6J235
TRIAGE
6J225
T 6J117
WORKSPACE
6J243
CONFERENCE
6J302
CLINIC MGR
6J310
ADM MGR
6J241
SHARED COPY
6J124
ADVOCATE
6J116
ITAC
6J115
WC
6J111B
TYP ALC
6J284
INTV
6J110D INTV
6J111C
INTV
6J111D
TYP WORKSPACE
6J218
IOP TEST
6J122
SOC WRK
6J114TYP INTV
6J110C
PHYS, RES, PROV &
STUDENTS
6J315
PHYS, RES, STUDENT
6J308
TYP CLEAN/ EQUIP
6J261
TYP SOILED
6J210
HK
6J212
TYP RECEPT
6J110A
RECEPT
6J111A
ISO T
6J281A
SHARED M-P CONF
6J125
FEMALE
6J103
MALE
6J101
TYP STAFF LOUNGE
6J317
TYP PROCED
6J260
RN MGR
6J242
SERVICE BAY
6J104
SERVICE BAY
6J299
NORM ELEC
6J299B
EMER ELEC
6J299A
EXAM
6J201
TYP WORKSPACE
6J219
WORKSPACE
6J257
EXAM
6J272
EXAM
6J254
EXAM
6J252
TRIAGE
6J229
TR
6J102A
CONSULT
6J132
OFFICE
6J311
CONFERENCE
6J309
EXAM
6J228
TYP SPEC EXAM
6J209
EXAM
6J203 EXAM
6J224
EXAM
6J222
EXAM
6J223
EXAM
6J230
EXAM
6J221
EXAM
6J231
MH OFF
6J248
MH OFF
6J246
TELE-MED
6J240
EXAM
6J270
EXAM
6J253
EXAM
6J268
SPEC EXAM
6J264
SPEC EXAM
6J282
EXAM
6J276
EXAM
6J278
PUB ELEV LOBBY
6J100
AISLE
6J-CO1D
AISLE
6J-CO1C
AISLE
6J-CO1B
KIOSK
6J131
AISLE
6J-CO1A
TYP SERV ELEV LOBBY
6J105
CORR
6J-C02
CORR
6J-C03
CORR
6J-C04
CORR
6J-C05
CORR
6J-C06 CORR
6J-C07
CORR
6J-C08ALC
6J280
ALC
6J266A
ALC
6J258
ALC
6J243A
TYP ALC
6J207
ALC
6J220
ALC
6J234
CORR
6J-C010
CORR
6J-C01
EWC
6J127
KIOSK
6J121
EWC
6J117A
LVSR
6J102B
TYP CC
6J234B
CHRG NS
6J303
UNASSN
6J316
TYP HK
6J263
CONSULT
6J112
ALC
6J243B
CC
6J266B
STAIR
6J-STJ-3
LOW VOLT
6J300A
CLOS
1J100A
CAFE SERVING
1J106B
NORM ELEC
6J104B
ELEV
JS-5
ELEV
JS-6
ELEV
JP-1
ELEV
JP-3
ELEV
JP-2
ELEV
JP-4
SHAFT
SHJ01
SHAFT
SHJ02
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AC-061
J
LEVEL 6 REFLECTIVE CEILING PLAN
BUILDING J
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R H
O U
S E
3/32" = 1'-0"E1
SIXTH FLOOR REFLECTIVE CEILING PLAN BUILDING J
KEY PLAN
GENERAL NOTES ARCHITECTURAL
A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY
TO ADD OR REMOVE CABLES WITHOUT RESEALING.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE
EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.
GENERAL NOTES REFLECTED CEILING
A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL SHEET NOTES
GYP. BD. CEILING SYSTEM
2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.
DOWN LIGHT FIXTURE
LEGEND
KEYED NOTES
1'X4' LIGHT FIXTURE
8' X 7" LIGHT FIXTURE
2'X4' LIGHT FIXTURE
2'X2' SUPPLY
2'X2' RETURN
INTV
7J111C
T 7J120
T 7J126
INTV
7J111D
HK
7J210
PHYS, RES, PROV,
STUDENT
7J312
TYP EXAM
7J201
T 7J220A
T 7J221A
ST
7J209
ISO SPEC EXAM
7J214
TRIAGE/ TELE-RET
7J225
CHS EXAM
7J202
CLEAN/ MED
7J213
EXAM
7J204
SPEC EXAM
7J207
WORKSPACE
7J230
TRIAGE
7J200
SHARED COPY
7J123CHS WAITING
7J125
EXAM
7J219
EXAM
7J221
EXAM
7J218
ISO T
7J231A
EXAM
7J220
MODULE F: WAITING
7J110
RECEPT
7J111A
CHS: PROCED
7J206
TYP NUTRN
7J112T
MEDS
7J113
CLEAN/ EQUIP
7J115
SOILED
7J116
T 7J118
T
7J114 NS STN
7J112Q
NS STN
7J112S
ISO TRTMT
7J119
SPEC EXAM
7J263
ISO EXAM
7J281
TRIAGE
7J271
EXAM/ (NS MGR)
7J275
WORKSPACE
7J262
EXAM
7J253
EXAM
7J269
EXAM
7J279
TRIAGE
7J251
EXAM
7J270
EXAM
7J272
EXAM
7J266
SPEC EXAM
7J260
SPEC EXAM
7J257
EXAM
7J277
EXAM
7J268
SPEC EXAM
7J280
EXAM
7J274
PHYS/ RES/ STUDENT
7J307
WORKSPACE
7J241
WC
7J111B
EXAM
7J254
EXAM
7J250
FAMILY COUNSEL
7J247
EXAM
7J252
MODULE B: WAITING
7J111
T 7J258A
CONSULT
7J248
PROCED
7J258
MOD F/B CONF
7J311
CLEAN/ MED
7J235
EXAM
7J245
CHIEF
7J308
EEG READING
7J309
EMG
7J236
EEG
7J237
TYP EEG
7J239
EXAM
7J246
EEG STOR/ EQ
7J244
TYP EMG
7J238
EEG WORK
7J310
CLEAN/MED
7J283
WORKSPACE
7J265
TR
7J102A
T 7J206A
SOILED
7J208
ST
7J212 CLEAN SUPPLY
7J232
SPEC EXAM
7J233
EXAM
7J227
EXAM
7J255
EEG STOR/ MOVE
7J243
INFUS TRTMT
7J112F
STAFF LOUNGE
7J317
FEMALE
7J103
MALE
7J101
NORM ELEC
6J104B
SERVICE BAY
7J104
NORM ELEC
7J104B
SERVICE BAY
7J299
NORM ELEC
7J299B
EMER ELEC
7J299A
ISO T
7J119A
WORK
7J112P
ISO T
7J281A
EXAM
7J267
EXAM
7J276
EXAM
7J226
CONSULT/OFF
7J224
ISO EXAM
7J231
EXAM
7J228
PCMC
7J215
WMNS COORD
7J217
EXAM
7J229
CORR
7J-C03
EXAM
7J203
T 7J201A
WM PHYS, RES, PROV,
STUDENT
7J315
CC NRS MGR
7J301
LOW VOLT
7J300A
T 7J202A
T 7J217A
CONF
7J122
NUTRN
7J112R
SERV ELEV LOBBY
7J305
AISLE
7J-CO1A
INFUS TRTMT
7J112A
TYP INFUS
TRTMT
7J112B
INFUS TRTMT
7J112C
INFUS TRTMT
7J112D
INFUS TRTMT
7J112E
INFUS TRTMT
7J112G
INFUS TRTMT
7J112H
INFUS TRTMT
7J112I
INFUS TRTMT
7J112J
INFUS TRTMT
7J112K
INFUS TRTMT
7J112L
INFUS TRTMT
7J112M
INFUS TRTMT
7J112N
INFUS TRTMT
7J112OAISLE
7J-CO1B
AISLE
7J-CO1C
ELEV
JS-5
ELEV
JS-6
ELEV
JP-1
ELEV
JP-3
ELEV
JP-2
ELEV
JP-4
CORR
7J-C01
RECEPT
7J125A
CORR
7J-C02
CORR
7J-C04
CORR
7J-C05
CORR
7J-C06
CORR
7J-C07
CORR
7J-C08
CORR
7J-C09
CORR
7J-C010
ALC
7J230A
ALC
7J242
ALC
7J256
CC
7J264 ALC
7J278
EWC
7J127
KIOSK
7J121
SHAFT
SHJ01
SHAFT
SHJ02
ALC
7J216B
CHS:LAB
7J216A
CC
7J206B
ALC
7J282
ALC
7J240
ALC
7J262A
LVSR
7J102B
ALC
7J202B
ALC
7J201B
ALC
7J220B
ALC
7J221B
ALC
7J217B
ALC
7J231B
CC
7J241A
HK
7J261
ALC
7J285
VEST
7J-C02A
KIOSK
7J125B
WORKSPACE
7J216
EEG WAITING
7J110A
CLEAN/EQUIP
7J259
STAIR
7J-STJ-3
CC CASE MGR
7J306
CC PSA
7J303
CC ANALYST
7J302
TR
7J300B
PUB ELEV LOBBY
7J100
Room 4J450
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AC-071
J
LEVEL 7 REFLECTIVE CEILING PLAN
BUILDING J
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R H
O U
S E
3/32" = 1'-0"F1
SEVENTH FLOOR REFLECTIVE CEILING PLAN BUILDING J
RE
TH
CR
F
OC
C1
S
GENERAL NOTE DEMOLITION
A. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION. BRING SIGNIFICANT
DISCREPANCIES TO THE ATTENTION OF THE COR. FOR REVIEW.
B. COORDINATE DEMOLITION TIMING WITH THE COR. PRIOR TO START.
C. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION, INCLUDING
MECHANICAL & FIRE SUPPRESSION SYSTEMS.
D. UPON COMPLETION OF DEMOLITION, PREPARE SUBSTRATE AS REQUIRED TO RECEIVE NEW FINISH
PER ARCHITECTURAL DRAWINGS. REPAIR ANY DAMAGE INCURRED DURING OR PRIOR TO THE
START OF WORK TO MATCH EXISTING CONDITION INCLUDING FIREPROOF MATERIALS.
E. SALVAGE AND RETURN TO C.O.R. EXISTING LIGHT FIXTURES TO BE REMOVED PER DRAWINGS.
F. EXISTING WALL MOUNTED DEVICES TO REMAIN UNLESS NOTED OTHERWISE, INCLUDED BUT NOT
LIMITED TO THERMOSTATS, LIGHT SWITCHES, OUTLETS, DATA PORTS, INTERIOR DEVICES, ETC.
FOLLOW ELECTRICAL, MECHANICAL, AND TELECOMMUNICATION DRAWINGS.
G. REMOVE EXISTING SIGNAGE, COORDINATE WITH C.O.R. ANY REQUIRED NEW SIGNAGE.
H. FOLLOW MECHANICAL DRAWINGS FOR GRILL, DIFFUSER, AND REGISTER DEMOLITION, CAP AND
REPAIR AS REQUIRED.
I. RELOCATE EXISTING WATER, DRAIN, CONDENSATE, & STEAM LINES OUTSIDE NEW T.R., REFER TO
PLUMBING DRAWINGS FOR COORDINATION.
GENERAL NOTES ARCHITECTURAL
A. THE COR. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO PENETRATE WALLS. INSTALLED PER
MANUFACTURERS REQUIREMENTS TO MATCH RATING OF WALL.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. FOLLOW INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. FOLLOW SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. FOLLOW SHEET 000-AJ-605 FOR ALL FINISHES
GENERAL NOTES REFLECTED CEILING
A. RESTORE AFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL NOTES INFECTION CONTROL
A. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL, PRECAUTION CLASS III. WHERE CORRIDOR IS SHOWN WITH IN AREA OF
HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET THE MORE STRINGENT REQUIREMENT.
B. ALL OTHER AREAS ON THIS SHEET PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE C, LOW
RISK GROUP AND INFECTION CONTROL PRECAUTION CLASS II UNLESS OTHERWISE NOTED.
C. REFER TO SHEET GI003 FOR SYMBOLS AND ABBREVIATIONS.
GENERAL SHEET NOTES
KEYED NOTES - DEMOLITION
KEYED NOTES
KEYED NOTES - RENOVATION
Room Name
LEGEND
LEGACY ROOM NUMBER
SIGNAGE ROOM NUMBER
TR
1H211
1H137
C7
03-AJ-013
E7
03-AJ-013
2R
10R11R 12R
18R
1H211
1R 29R
81R
115R
47R
128R
128R
19R
TR
1H211
1H137
1D
20D
7D
TR
1H211
1H137
79D
79D
5D
2D
4R
TR
1H211
1H137
8R 4R
27R
47R
10R
28R
2R
47R
27R
10R
2R
28R
47R
27R
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AJ-013
J
ENLARGED PLANS BUILDING H
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
3/8" = 1'-0"C3
ENLARGED FIRST FLOOR PLAN - RENOVATION
ROOM 1H2113/8" = 1'-0"C1
ENLARGED FIRST FLOOR PLAN - DEMOLITION
ROOM 1H211
3/8" = 1'-0"E1
ENLARGED FIRST FLOOR RCP - DEMOLITION
ROOM 1H211 3/8" = 1'-0"E3
ENLARGED FIRST FLOOR RCP - RENOVATION
ROOM 1H211
3/8" = 1'-0"C7
BUILDING SECTION 1
ROOM 1H211
3/8" = 1'-0"E7
BUILDING SECTION 2
ROOM 1H211
1R NEW DOOR, RE: SHEET 000-AJ-605 DOOR SCHEDULE.
2R INSTALL 4' X 8' 3/4" FIRE RATED PLYWOOD, VERTICAL, AC GRADE, 6" A.F.F. PER
WALL TYPE REFER TO SHEET 000-AJ-601. PAINT PLYWOOD W/ HIGH GLOSS, TWO
COATS, FIRE RESISTANT PAINT - COLOR WHITE. DO NOT PAINT OVER ONE FIRE
RATED STAMP ON EACH SHEET OF PLYWOOD.
4R CONTRACTOR TO PROVIDE APPROVAL SUBMITTAL FOR THE FIRE SPRINKLER
SYSTEM MODIFICATIONS IN EXISTING AND NEW TELECOMMUNICATION ROOMS
AND TELECOMMUNICATION SPACES. RELOCATE OR ADD NEW HEADS WHERE
REQUIRED, SPRINKLER HEADS TO BE WITHIN 12" OF THE CONCRETE
FLOOR/ROOF DECK ABOVE IN COMPLIANCE WITH NFPA13. COORDINATE
SPRINKLER SYSTEM SHUTDOWN/SCHEDULE WITH VA C.O.R. AND LOCAL FIRE
DEPARTMENT/AUTHORITY HAVING JURISDICTION.
8R OPEN TO STRUCTURE ABOVE.
10R 4" NEW VINYL BASE, COLOR TO MATCH EXISTING.
11R NEW STATIC DISSIPATIVE FLOORING TILE.
12R PAINT WALL FULL HEIGHT. FINISH TO MATCH EXISTING. PATCH AND REPAIR ANY
WALL DAMAGE TO MATCH EXISTING ADJACENT FINISHES AND TEXTURES.
18R NEW SEMI-RECESSED CLEAN AGENT FIRE EXTINGUISHER CABINET (DEPENDING
ON WALL CONDITION). MOUNT @ 48" TOP OF CABINET. FIELD VERIFICATION
REQUIRED.
19R NEW CARD READER AND KEYPAD.
27R NEW CABLE TRAY. RE: TELECOM.
28R NEW TELECOMMUNICATION EQUIPMENT, RE: TELECOM.
29R PATCH AND REPAIR PAINT AND BASE AT NEW WALL.
47R MECHANICAL UNIT, RE: MECHANICAL.
81R FLOORING TRANISTION REQUIRED, RE: SHEET AJ-602.
115R PAINT ENTIRE ROOM W/ HIGH GLOSS WHITE PAINT EXCEPT FOR PLYWOOD
WALLS.
128R PATCH EXISTING WALL WHERE DUCTWORK WAS REMOVED. MATCH EXISTING
CONSTRUCTION TYPE REFER TO MECHANICAL.
1D REMOVE EXISTING DOOR AND FRAME
2D DEMOLISH EXISTING LAY-IN CEILING ASSEMBLY.
5D REMOVE EXISTING LIGHT FIXTURE, RETURN TO OWNER?. RE: ELECTRICAL
7D INFECTIONS CONTROL PLAN DETAIL, RE: F5/000-AJ-604
20D REMOVE EXISTING FLOORING, VINYL AND BASE. PREP SLAB TO RECEIVE NEW
MATERIAL.
79D RELOCATE EXISTING DIFFUSER AND DUCTWORK. REFER TO MECHANICAL.
NORTH NORTH
NORTHNORTH
CR
F
OC
C 4
C
C
C
C
C2
C
J
S S
CR
GENERAL NOTE DEMOLITION
A. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION. BRING SIGNIFICANT
DISCREPANCIES TO THE ATTENTION OF THE COR. FOR REVIEW.
B. COORDINATE DEMOLITION TIMING WITH THE COR. PRIOR TO START.
C. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION, INCLUDING
MECHANICAL & FIRE SUPPRESSION SYSTEMS.
D. UPON COMPLETION OF DEMOLITION, PREPARE SUBSTRATE AS REQUIRED TO RECEIVE NEW FINISH
PER ARCHITECTURAL DRAWINGS. REPAIR ANY DAMAGE INCURRED DURING OR PRIOR TO THE
START OF WORK TO MATCH EXISTING CONDITION INCLUDING FIREPROOF MATERIALS.
E. SALVAGE AND RETURN TO C.O.R. EXISTING LIGHT FIXTURES TO BE REMOVED PER DRAWINGS.
F. EXISTING WALL MOUNTED DEVICES TO REMAIN UNLESS NOTED OTHERWISE, INCLUDED BUT NOT
LIMITED TO THERMOSTATS, LIGHT SWITCHES, OUTLETS, DATA PORTS, INTERIOR DEVICES, ETC.
FOLLOW ELECTRICAL, MECHANICAL, AND TELECOMMUNICATION DRAWINGS.
G. REMOVE EXISTING SIGNAGE, COORDINATE WITH C.O.R. ANY REQUIRED NEW SIGNAGE.
H. FOLLOW MECHANICAL DRAWINGS FOR GRILL, DIFFUSER, AND REGISTER DEMOLITION, CAP AND
REPAIR AS REQUIRED.
I. RELOCATE EXISTING WATER, DRAIN, CONDENSATE, & STEAM LINES OUTSIDE NEW T.R., REFER TO
PLUMBING DRAWINGS FOR COORDINATION.
GENERAL NOTES ARCHITECTURAL
A. THE COR. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO PENETRATE WALLS. INSTALLED PER
MANUFACTURERS REQUIREMENTS TO MATCH RATING OF WALL.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. FOLLOW INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. FOLLOW SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. FOLLOW SHEET 000-AJ-605 FOR ALL FINISHES
GENERAL NOTES REFLECTED CEILING
A. RESTORE AFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL NOTES INFECTION CONTROL
A. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL, PRECAUTION CLASS III. WHERE CORRIDOR IS SHOWN WITH IN AREA OF
HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET THE MORE STRINGENT REQUIREMENT.
B. ALL OTHER AREAS ON THIS SHEET PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE C, LOW
RISK GROUP AND INFECTION CONTROL PRECAUTION CLASS II UNLESS OTHERWISE NOTED.
C. REFER TO SHEET GI003 FOR SYMBOLS AND ABBREVIATIONS.
GENERAL SHEET NOTES
KEYED NOTES - DEMOLITION
KEYED NOTES
KEYED NOTES - RENOVATION
Room Name
LEGEND
LEGACY ROOM NUMBER
SIGNAGE ROOM NUMBER
PM & MSA: CONF
3H130
3H100
17' - 8 1/2"
/4
1D
82D
TR
3H130
3H130A
99D
7D
PM & MSA: CONF
3H130
3H100
C7
03-AJ-033
F7
03-AJ-033
2R
10R
11R
8R
106R
1R18R
TR
3H130
3H130A
3H130A
23R
81R
10R
1A
115R
124R
126R
/4 " 47D
12R
PM & MSA: CONF
3H130
3H100
5D
83D
4R
79D79D
PM & MSA: CONF
3H130
3H100
TR
3H130
3H130A
107R
8R
4R
4R
27R
104R
2R
28R
10R
47R
10R
2R
28R
47R
27R
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AJ-033
J
ENLARGED PLANS BUILDING H
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
100% FINAL BID
DOCUMENTS
629-22-700
3/8" = 1'-0"C1
ENLARGED THIRD FLOOR PLAN - DEMOLITION
ROOM 3H130 3/8" = 1'-0"C3
ENLARGED THIRD FLOOR PLAN - RENOVATION
ROOM 3H130 & 3H130A
3/8" = 1'-0"F1
ENLARGED FIRST FLOOR RCP - DEMOLITION
ROOM 3H130 3/8" = 1'-0"F3
ENLARGED FIRST FLOOR RCP - RENOVATION
ROOMS 3H130A & 3H130
3/8" = 1'-0"C7
TR SECTION
ROOM 3H130A
3/8" = 1'-0"F7
TR & CONFERENCE ROOM SECTION
ROOM 3H130A & 3H130
1R NEW DOOR, RE: SHEET 000-AJ-605 DOOR SCHEDULE.
2R INSTALL 4' X 8' 3/4" FIRE RATED PLYWOOD, VERTICAL, AC GRADE, 6" A.F.F. PER
WALL TYPE REFER TO SHEET 000-AJ-601. PAINT PLYWOOD W/ HIGH GLOSS, TWO
COATS, FIRE RESISTANT PAINT - COLOR WHITE. DO NOT PAINT OVER ONE FIRE
RATED STAMP ON EACH SHEET OF PLYWOOD.
4R CONTRACTOR TO PROVIDE APPROVAL SUBMITTAL FOR THE FIRE SPRINKLER
SYSTEM MODIFICATIONS IN EXISTING AND NEW TELECOMMUNICATION ROOMS
AND TELECOMMUNICATION SPACES. RELOCATE OR ADD NEW HEADS WHERE
REQUIRED, SPRINKLER HEADS TO BE WITHIN 12" OF THE CONCRETE
FLOOR/ROOF DECK ABOVE IN COMPLIANCE WITH NFPA13. COORDINATE
SPRINKLER SYSTEM SHUTDOWN/SCHEDULE WITH VA C.O.R. AND LOCAL FIRE
DEPARTMENT/AUTHORITY HAVING JURISDICTION.
8R OPEN TO STRUCTURE ABOVE.
10R 4" NEW VINYL BASE, COLOR TO MATCH EXISTING.
11R NEW STATIC DISSIPATIVE FLOORING TILE.
12R PAINT WALL FULL HEIGHT. FINISH TO MATCH EXISTING. PATCH AND REPAIR ANY
WALL DAMAGE TO MATCH EXISTING ADJACENT FINISHES AND TEXTURES.
18R NEW SEMI-RECESSED CLEAN AGENT FIRE EXTINGUISHER CABINET (DEPENDING
ON WALL CONDITION). MOUNT @ 48" TOP OF CABINET. FIELD VERIFICATION
REQUIRED.
23R PATCH AND REPAIR EXISTING WALL INTEROR AND EXTERIOR WITH THE SAME
MATERIAL AS EXISTING FINISH CONDITION.
27R NEW CABLE TRAY. RE: TELECOM.
28R NEW TELECOMMUNICATION EQUIPMENT, RE: TELECOM.
47R MECHANICAL UNIT, RE: MECHANICAL.
81R FLOORING TRANISTION REQUIRED, RE: SHEET AJ-602.
104R RELOCATED LIGTH FIXTURE.
106R PAINT ENTIRE ROOM TO MATCH EXISTING WALL COLOR.
107R PATCH REPAIR CEILING AND TILE GRID AT NEW WALL LOCATION.
115R PAINT ENTIRE ROOM W/ HIGH GLOSS WHITE PAINT EXCEPT FOR PLYWOOD
WALLS.
124R LOCATION OF RELOCATED WALL MONITOR, REFER TO ELECTRICAL.
126R OPEN EXISTING WALL TO PLACE CONDENSATE LINE AND PATH BACK TO MATCH
PRE-EXISTING CONDITIONS. REFER TO MECHANICAL.
1D REMOVE EXISTING DOOR AND FRAME
5D REMOVE EXISTING LIGHT FIXTURE, RETURN TO OWNER?. RE: ELECTRICAL
7D INFECTIONS CONTROL PLAN DETAIL, RE: F5/000-AJ-604
47D EXISTING MECHANICAL UNIT TO REMAIN, RE: MECHANICAL.
79D RELOCATE EXISTING DIFFUSER AND DUCTWORK. REFER TO MECHANICAL.
82D REMOVE FLOORING TO NEW WALL LOCATION PROTECT FLOOR TO REMAIN.
83D REMOVE CEILING TILE AND GRID. KEEP TILES FOR ADJACENT RENOVATED
CEILING.
99D REMOVE AND RELOCATE EXISTING WALL MONITOR AND IT CONDUIT PATHWAY
TO NEW WALL, REFER TO ELECTRICAL.
NORTH NORTH
F
C R
O C
C1
TR
4H113
4H123
1D
20D
7D
TR
4H113
4H123
C7
03-AJ-043
F7
03-AJ-043
2R
10R
11R 12R
1A
4H130A
1R
29R
81R
115R
8R
19R
18R
125R
128R
47R
TR
4H113
4H123
5D
79D
79D
2D
4R TR
4H113
4H123
8R
4R 27R
10R
28R
2R
47R
27R
10R
47R
27R
2R
28R
GENERAL NOTE DEMOLITION
A. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION. BRING SIGNIFICANT
DISCREPANCIES TO THE ATTENTION OF THE COR. FOR REVIEW.
B. COORDINATE DEMOLITION TIMING WITH THE COR. PRIOR TO START.
C. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION, INCLUDING
MECHANICAL & FIRE SUPPRESSION SYSTEMS.
D. UPON COMPLETION OF DEMOLITION, PREPARE SUBSTRATE AS REQUIRED TO RECEIVE NEW FINISH
PER ARCHITECTURAL DRAWINGS. REPAIR ANY DAMAGE INCURRED DURING OR PRIOR TO THE
START OF WORK TO MATCH EXISTING CONDITION INCLUDING FIREPROOF MATERIALS.
E. SALVAGE AND RETURN TO C.O.R. EXISTING LIGHT FIXTURES TO BE REMOVED PER DRAWINGS.
F. EXISTING WALL MOUNTED DEVICES TO REMAIN UNLESS NOTED OTHERWISE, INCLUDED BUT NOT
LIMITED TO THERMOSTATS, LIGHT SWITCHES, OUTLETS, DATA PORTS, INTERIOR DEVICES, ETC.
FOLLOW ELECTRICAL, MECHANICAL, AND TELECOMMUNICATION DRAWINGS.
G. REMOVE EXISTING SIGNAGE, COORDINATE WITH C.O.R. ANY REQUIRED NEW SIGNAGE.
H. FOLLOW MECHANICAL DRAWINGS FOR GRILL, DIFFUSER, AND REGISTER DEMOLITION, CAP AND
REPAIR AS REQUIRED.
I. RELOCATE EXISTING WATER, DRAIN, CONDENSATE, & STEAM LINES OUTSIDE NEW T.R., REFER TO
PLUMBING DRAWINGS FOR COORDINATION.
GENERAL NOTES ARCHITECTURAL
A. THE COR. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE
AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.
B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.
C. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO PENETRATE WALLS. INSTALLED PER
MANUFACTURERS REQUIREMENTS TO MATCH RATING OF WALL.
D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT
BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.
E. FOLLOW INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
F. FOLLOW SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.
G. FOLLOW SHEET 000-AJ-605 FOR ALL FINISHES
GENERAL NOTES REFLECTED CEILING
A. RESTORE AFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.
B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.
GENERAL NOTES INFECTION CONTROL
A. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL, PRECAUTION CLASS III. WHERE CORRIDOR IS SHOWN WITH IN AREA OF
HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET THE MORE STRINGENT REQUIREMENT.
B. ALL OTHER AREAS ON THIS SHEET PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE C, LOW
RISK GROUP AND INFECTION CONTROL PRECAUTION CLASS II UNLESS OTHERWISE NOTED.
C. REFER TO SHEET GI003 FOR SYMBOLS AND ABBREVIATIONS.
GENERAL SHEET NOTES
KEYED NOTES - DEMOLITION
KEYED NOTES
KEYED NOTES - RENOVATION
Room Name
LEGEND
LEGACY ROOM NUMBER
SIGNAGE ROOM NUMBER
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023
100% FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s
/2 -0
N e w O rl e a n s
E H
R M
/2 -0
N
O L A
E H
R M
C o n c o u rs e
A rc h
P ro d u c ti o n -R
.r v t
03-AJ-043
J
ENLARGED PLANS BUILDING H
ES BS
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL…