2.14 - Drawings 14 of 17 - 04-ED-011 to 10-EP-011.pdf
PDF 19 MB Posted
- Solicitation number
- 36C77623B0038
About this file
This document provides details on a federal contract opportunity for infrastructure upgrades at a Veterans Affairs facility in New Orleans, Louisiana. The solicitation number is 36C77623B0038 and is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin. It is seeking construction services for NOLA EHRM Infrastructure Upgrades at the New Orleans location, as outlined in the related file containing construction drawings. The opportunity type is listed as a solicitation. No further information is provided on response due dates, award timing, pricing terms, or set-asides. The summary focuses on the federal agency and location involved, as well as the purpose of the infrastructure upgrade project.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THIS DRAWING WAS PRODUCED FROM ORIGINAL
AS-BUILT DRAWINGS AND FIELD OBSERVATIONS, AND
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
UP
UP
UP
DN
J
DNDN
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
LOUNGE
1K116
ST
1K116A
ST
1K116B
DISPATCH & CUBICLES
1K114
TRANS SUPV
1K114A
SECURITY
1K106
TR
1K104
1K104
ELEC
1K108
ATTENDANT OFFICE
1K112
WC STOR
1K109
STAIR
STK-1
STAIR
STK-2
EQUIPMENT STORAGE
1K105
EQUIPMENT STORAGE
1K107
MECHANICAL
1K110
SECURITY
1K101
TR
1K103
1K103
STAIR
STK-3
STAIR
STK-4
OIL / WATER
INTERCEPTOR
1K128
04-ED-011
04-ED-011
04-ED-011
(E) DIST BOARD 'DC432'
(E) XFMR 'T6'
(E) DIST BOARD 'D424'
(E) PNL 'EQP4212'
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(X)UNLABELEDMOUNTED ON
CABLE TRAY
(TYP.)
(X)UNLABELED
(X)UNLABELED
TR
1K104
1K104
(E) PNL 'EQP4211'
(X)UNLABELED
(X)UNLABELED
(X)UNLABELED
(X)UNLABELED
(X)UNLABELED
MOUNTED ON
CABLE TRAY
(TYP.)
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(X)EQP4211-6,8
(X)UNLABELED
TR
1K103
1K103
(E) PNL 'R421A'
(E) PNL 'R421B'
ELEC
1K108
(E) SWBD 'USS04'
(E) SWBD 'EUSS04'
(E) PNL 'RC23'
(E) XFMR 'T3'
(E) PNL 'LC43'
(E) DIST BOARD 'DC433'
(E) PNL 'ELDC43'
(E) DIST BOARD 'EQDC43'
(E) XFMR 'T6'
(E) DIST BOARD 'EQDC23'
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
04-ED-011
OVERALL FIRST FLOOR POWER
DEMOLITION PLAN - BLDG. 04
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 04 POWER OVERALL DEMOLITION PLAN - LEVEL 1
1/4" = 1'-0"3
ENLARGED POWER DEMO PLAN - TR 1K104
1/4" = 1'-0"4
ENLARGED POWER DEMO PLAN - TR 1K103
1/4" = 1'-0"2
ENLARGED POWER DEMO PLAN - ELEC 1K108
DEMOLITION GENERAL NOTES
1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE ALL INTERRUPTIONS SERVICES WITH THE COR PRIOR TO
INITIATION OF WORK. NO DEMOLITION SHALL OCCUR UNTIL AFTER THE NEW OR
REPLACEMENT SYSTEMS ARE IN PLACE AND READY FOR CUT OVER.
3. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
4. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
5. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
6. PARTICULAR ATTENTION SHALL BE GIVEN TO THE PROTECTION OF EXISTING STRUCTURE
AND FINISHES TO PREVENT ANY DAMAGE OF EXISTING FINISHES. ANY ACCIDENTAL DAMAGE
INCURRED TO EXISTING CONDITIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO REPAIR OR CORRECT.
7. CONTRACTOR SHALL CONFIRM EXISTING CIRCUITING TO UPS EQUIPMENT AND RACK
MOUNTED RECEPTACLES IN EXISTING TELECOMMUNICATION ROOMS PRIOR TO
DEMOLITION. ANY EXISTING FEEDERS NOT SUPPLYING UPS EQUIPMENT OR RACK MOUNTED
RECEPTACLES TO REMAIN.
8. EXISTING RACK MOUNTED RECEPTACLES BEING UTILIZED TO REMAIN. CONTRACTOR TO
VERIFY RECEPTACLE UTLIZATION PRIOR TO DEMOLITION.
PLAN NOTES
1 EXISTING ELECTRICAL RECEPTACLES TO BE REMOVED. CONTRACTOR TO REMOVE
EXISTING CONDUIT AND CONDUCTORS BACK TO SOURCE.
2 EXISTING ELECTRICAL RECEPTACLE TO REMAIN.
3 EXISTING ELECTRICAL PANEL TO REMAIN.
3/32" = 1'-0"5
BLDG. 04 POWER DEMOLITION PLAN 4TH FLR - CONCOURSE
Revisions: Date:
UP
UP
DN
F
F F
F F
F
F F
F
F
DNDN
CB
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
LOUNGE
1K116
ST
1K116A
ST
1K116B
DISPATCH & CUBICLES
1K114
TRANS SUPV
1K114A
SECURITY
1K106
TR
1K104
1K104
ELEC
1K108
ATTENDANT OFFICE
1K112
WC STOR
1K109
STAIR
STK-1
STAIR
STK-2
EQUIPMENT STORAGE
1K105
EQUIPMENT STORAGE
1K107
MECHANICAL
1K110
SECURITY
1K101
TR
1K103
1K103
STAIR
STK-3
STAIR
STK-4
OIL / WATER
INTERCEPTOR
1K128
04-EP-011
04-EP-011
04-EP-011
04-EP-011
(E) PNL 'R421A'
(E) PNL 'R421B'
ELEC
1K108
(E) PNL 'EQP4212'
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
TR
1K104
1K104
R4212-1,3,5
EQP4213-17,19,21
60AF
60AT
PNL 'R4212' 1
EQP4213-2,4
EQP4213-10,12
EQP4213-6,8
EQP4213-14,16
2 2
20AS
20AF
20AS
20AF
30AS
30AF
30AS
30AF
EQP4212-6,8 2
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E) PNL 'EQP4211'
R4211-1,3,5
EQP4213-18,20,22
60AS
60AF
PNL 'R4211' 1
30AS
30AF
30AS
30AF
EQP4213-1,3
EQP4213-9,11
EQP4213-13,15
30AS
30AF
EQP4213-5,7
EQP4211-6,8
TR
1K103
1K103
(E) SWBD 'USS04'
(E) SWBD 'EUSS04'
(E) PNL 'RC23'
(E) XFMR 'T3'
(E) PNL 'LC43'
(E) DIST BOARD 'DC433'
(E) PNL 'ELDC43'
(E) DIST BOARD 'EQDC43'
(E) XFMR 'T6'
(E) DIST BOARD 'EQDC23'
(E) DIST BOARD 'DC432'
(E) XFMR 'T6'
(E) DIST BOARD 'D424'
XFMR 'T5-ECR4213'
PNL 'EQP4213'
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
04-EP-011
OVERALL FIRST FLOOR POWER PLAN -
BLDG. 04
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 04 POWER OVERALL PLAN - LEVEL 1
GENERAL NOTES
1. COORDINATE EXACT LOCATION OF MECHANICAL AND TELECOMMUNICATIONS EQUIPMENT
WITH THE CORRESPONDING DISCIPLINE'S DRAWINGS.
2. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
3. REFER TO ASSOCIATED TN SHEET FOR RACK QUANTITIES IN EXISTING AND NEW TR
SPACES.
4. ASSUMED CAPACITY AND LOAD AVAILABLE TO PANELS BEING USED IN SCOPE OF WORK.
CONTRACTOR TO VERIFY SUFFICIENT LOAD IS AVAILABLE PRIOR TO ADDING EQUIPMENT TO
ASSOCIATED PANELS TO AVOID POTENTIAL PANEL OVERLOAD.
PLAN NOTES
1 CONTRACTOR TO PROVIDE NEW 208V, 100A, 3-PHASE PANEL FOR NEW RACK POWER. REFER
TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR CONDUIT AND CONDUCTOR SIZING
REQUIREMENTS.
2 CONTRACTOR TO PROVIDE NEW 208V, SINGLE-PHASE POWER IN HARD-WIRED JUNCTION
BOX FOR MECHANICAL HVAC UNIT. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001
FOR CONDUIT AND CONDUCTOR SIZING REQUIREMENTS.
3 USE EXISTING 225A SPARE BREAKERS IN EXISTING EQDC43 DISTRIBUTION PANEL FOR NEW
75KVA TRANSFORMER. REFER TO ELECTRICAL PANEL SCHEDULE ON 00-EJ-018 FOR
ADDITIONAL INFORMATION.
4 CONTRACTOR TO PROVIDE NEW 125A ENCLOSED CIRCUIT BREAKER AND ENCLOSURE TO BE
MOUNTED ON WALL. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR CONDUIT
AND CONDUCTOR SIZING REQUIREMENTS.
5 CONTRACTOR TO PROVIDE NEW 75KVA TRANSFORMER. REFER TO ELECTRICAL FEEDER
SCHEDULE ON 00-EG-001 FOR CONDUIT AND CONDUCTOR SIZING REQUIREMENTS.
6 CONTRACTOR TO PROVIDE NEW 208V, 225A, 3-PHASE SUB-FEED PANEL FOR NEW
MECHANICAL EQUIPMENT. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR
CONDUIT AND CONDUCTOR SIZING REQUIREMENTS.
7 CONTRACTOR TO PROVIDE NEW 120V POWER FOR NEW CIRC PUMP. REFER TO ELECTRICAL
FEEDER SCHEDULE ON 00-EG-001 FOR CONDUIT AND CONDUCTOR SIZING REQUIREMENTS.
8 CONTRACTOR TO PROVIDE NEW 208V, 60A, 3-PHASE POWER TERMINATING IN HARD-WIRED
JUNCTION BOX FOR NEW RACK POWER. JUNCTION BOX TO BE MOUNTED DIRECTLY ON
CABLE TRAY. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR CONDUIT AND
CONDUCTOR SIZING REQUIREMENTS.
1/4" = 1'-0"2
ENLARGED POWER PLAN - ELEC 1K108
1/4" = 1'-0"3
ENLARGED POWER PLAN - TR 1K104
1/4" = 1'-0"4
ENLARGED POWER PLAN - TR 1K103
3/32" = 1'-0"6
BLDG. 04 POWER PLAN 4TH FLR - CONCOURSE
1/4" = 1'-0"5
ENLARGED POWER PLAN - ELEC 1K102
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
UP
UP
UP
DNDN
05-ED-011
05-ED-011
05-ED-011
TR
1L110
1L110
SECURITY
1L108
TR
1L107
1L107
SECURITY
1L105
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
(E) PNL 'EQP5211'
TR
1L107
1L107
(E)UNLABELED
(E)UNLABELED (E)UNLABELED
(E)UNLABELED
(E)UNLABELED
MOUNTED ON
CABLE TRAY
(TYP.)
(X)UNLABELED
(E)UNLABELED
(X)UNLABELED
(X)UNLABELED
(E) PNL 'EQP5212'
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(X)UNLABELED
MOUNTED ON
CABLE TRAY
(TYP.)
(X)EQP5212-10,12
(X)UNLABELED
TR
1L110
1L110
(E) PNL 'R521A'
(E) PNL 'R521B'
(E) SWBD 'USS04'
(E) SWBD 'EUSS04'
(E) PNL 'RC23'
(E) XFMR 'T3'
(E) PNL 'LC43'
(E) DIST BOARD 'DC433'
(E) PNL 'ELDC43'
(E) DIST BOARD 'EQDC43'
(E) XFMR 'T6'
(E) DIST BOARD 'EQDC23'
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
05-ED-011
OVERALL FIRST FLOOR POWER
DEMOLITION PLAN - BLDG. 05
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 05 POWER OVERALL DEMOLITION PLAN - LEVEL 1
1/4" = 1'-0"3
ENLARGED POWER DEMO PLAN - TR 1L107
1/4" = 1'-0"4
ENLARGED POWER DEMO PLAN - TR 1L110
1/4" = 1'-0"2
ENLARGED POWER DEMO PLAN - ELEC 1L103
DEMOLITION GENERAL NOTES
1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE ALL INTERRUPTIONS SERVICES WITH THE COR PRIOR TO
INITIATION OF WORK. NO DEMOLITION SHALL OCCUR UNTIL AFTER THE NEW OR
REPLACEMENT SYSTEMS ARE IN PLACE AND READY FOR CUT OVER.
3. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
4. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
5. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
6. PARTICULAR ATTENTION SHALL BE GIVEN TO THE PROTECTION OF EXISTING STRUCTURE
AND FINISHES TO PREVENT ANY DAMAGE OF EXISTING FINISHES. ANY ACCIDENTAL DAMAGE
INCURRED TO EXISTING CONDITIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO REPAIR OR CORRECT.
7. CONTRACTOR SHALL CONFIRM EXISTING CIRCUITING TO UPS EQUIPMENT AND RACK
MOUNTED RECEPTACLES IN EXISTING TELECOMMUNICATION ROOMS PRIOR TO
DEMOLITION. ANY EXISTING FEEDERS NOT SUPPLYING UPS EQUIPMENT OR RACK MOUNTED
RECEPTACLES TO REMAIN.
8. EXISTING RACK MOUNTED RECEPTACLES BEING UTILIZED TO REMAIN. CONTRACTOR TO
VERIFY RECEPTACLE UTLIZATION PRIOR TO DEMOLITION.
PLAN NOTES
1 EXISTING ELECTRICAL RECEPTACLES TO BE REMOVED. CONTRACTOR TO REMOVE
EXISTING CONDUIT AND CONDUCTORS BACK TO SOURCE.
2 EXISTING ELECTRICAL RECEPTACLE TO REMAIN.
3 EXISTING ELECTRICAL PANEL TO REMAIN.
4 EXISTING UPS TO BE REMOVED. CONTRACTOR TO REMOVE EXISTING CONDUIT,
CONDUCTORS, AND JUNCTION BOXES BACK TO SOURCE.
3/32" = 1'-0"5
BLDG. 05 POWER DEMOLITION PLAN 4TH FLR - CONCOURSE
DN
(E) DIST BOARD 'D524' (E) XFMR 'T6'
(E) PNL 'R524'
(E) XFMR 'T3'
(E) PNL 'ER525'
(E) PNL 'ELS545'
(E) PNL 'L544'
(E) PNL 'LC544'(E) DIST BOARD '400A DX'
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
05-ED-041
OVERALL FOURTH FLOOR POWER
DEMOLITION PLAN - BLDG. 05
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 05 POWER OVERALL DEMOLITION PLAN - LEVEL 4
DEMOLITION GENERAL NOTES
1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE ALL INTERRUPTIONS SERVICES WITH THE COR PRIOR TO
INITIATION OF WORK. NO DEMOLITION SHALL OCCUR UNTIL AFTER THE NEW OR
REPLACEMENT SYSTEMS ARE IN PLACE AND READY FOR CUT OVER.
3. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
4. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
5. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
6. PARTICULAR ATTENTION SHALL BE GIVEN TO THE PROTECTION OF EXISTING STRUCTURE
AND FINISHES TO PREVENT ANY DAMAGE OF EXISTING FINISHES. ANY ACCIDENTAL DAMAGE
INCURRED TO EXISTING CONDITIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO REPAIR OR CORRECT.
7. CONTRACTOR SHALL CONFIRM EXISTING CIRCUITING TO UPS EQUIPMENT AND RACK
MOUNTED RECEPTACLES IN EXISTING TELECOMMUNICATION ROOMS PRIOR TO
DEMOLITION. ANY EXISTING FEEDERS NOT SUPPLYING UPS EQUIPMENT OR RACK MOUNTED
RECEPTACLES TO REMAIN.
8. EXISTING RACK MOUNTED RECEPTACLES BEING UTILIZED TO REMAIN. CONTRACTOR TO
VERIFY RECEPTACLE UTLIZATION PRIOR TO DEMOLITION.
UP
CB
F
F
F
F F
F
F F
F F
DNDN
05-EP-011
TR
1L107
1L107
TR
1L110
1L110
05-EP-011
05-EP-011
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
(E) PNL 'R521A'
(E) PNL 'R521B'
XFMR 'T5-EQP5213' 4
5PNL 'EQP5213'
(E)UNLABELED
(E)UNLABELED (E)UNLABELED
(E)UNLABELED
UNDER DISC.
(E)UNLABELED
(E)UNLABELED (E) PNL 'EQP5211'
TR
1L107
1L107
EQP5213-17,19,21
R5211-1,3,5
60AS
60AF
PNL 'R5211' 1
EQP5213-2,4
EQP5213-10,12
EQP5213-6,8
EQP5213-14,16
EQP5211-1,3
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E) PNL 'EQP5212'
TR
1L110
1L110
EQP5213-18,20,22
R5212-1,3,5
60AS
60AF
PNL 'R5212' 1
EQP5213-1,3
EQP5213-9,11
EQP5213-5,7 EQP5213-13,15
2 2
30AS
30AF
30AS
30AF
EQP5212-1,3
30AS
30AF
30AS
30AF
SECURITY
1L108
(E) SWBD 'USS04'
(E) SWBD 'EUSS04'
(E) PNL 'RC23'
(E) XFMR 'T3'
(E) PNL 'LC43'
(E) DIST BOARD 'DC433'
(E) PNL 'ELDC43'
(E) DIST BOARD 'EQDC43'
(E) XFMR 'T6'
(E) DIST BOARD 'EQDC23'
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
05-EP-011
OVERALL FIRST FLOOR POWER PLAN -
BLDG. 05
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 05 POWER OVERALL PLAN - LEVEL 1
GENERAL NOTES
1. COORDINATE EXACT LOCATION OF MECHANICAL AND TELECOMMUNICATIONS EQUIPMENT
WITH THE CORRESPONDING DISCIPLINE'S DRAWINGS.
2. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
3. REFER TO ASSOCIATED TN SHEET FOR RACK QUANTITIES IN EXISTING AND NEW TR
SPACES.
4. ASSUMED CAPACITY AND LOAD AVAILABLE TO PANELS BEING USED IN SCOPE OF WORK.
CONTRACTOR TO VERIFY SUFFICIENT LOAD IS AVAILABLE PRIOR TO ADDING EQUIPMENT TO
ASSOCIATED PANELS TO AVOID POTENTIAL PANEL OVERLOAD.
PLAN NOTES
1 CONTRACTOR TO PROVIDE NEW 208V, 100A, 3-PHASE PANEL FOR NEW RACK POWER. REFER
TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR CONDUIT AND CONDUCTOR SIZING
REQUIREMENTS.
2 CONTRACTOR TO PROVIDE NEW 208V, SINGLE-PHASE POWER IN HARD-WIRED JUNCTION
BOX FOR MECHANICAL HVAC UNIT. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001
FOR CONDUIT AND CONDUCTOR SIZING REQUIREMENTS.
3 CONTRACTOR TO PROVIDE NEW 125A ENCLOSED CIRCUIT BREAKER AND ENCLOSURE TO BE
MOUNTED ON WALL. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR CONDUIT
AND CONDUCTOR SIZING REQUIREMENTS.
4 CONTRACTOR TO PROVIDE NEW 75KVA TRANSFORMER. REFER TO ELECTRICAL FEEDER
SCHEDULE ON 00-EG-001 FOR CONDUIT AND CONDUCTOR SIZING REQUIREMENTS.
5 CONTRACTOR TO PROVIDE NEW 208V, 225A, 3-PHASE SUB-FEED PANEL FOR NEW
MECHANICAL EQUIPMENT. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR
CONDUIT AND CONDUCTOR SIZING REQUIREMENTS.
6 CONTRACTOR TO PROVIDE NEW 208V, 60A, 3-PHASE POWER TERMINATING IN HARD-WIRED
JUNCTION BOX FOR NEW RACK POWER. JUNCTION BOX TO BE MOUNTED DIRECTLY ON
CABLE TRAY. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR CONDUIT AND
CONDUCTOR SIZING REQUIREMENTS.
1/4" = 1'-0"2
ENLARGED POWER PLAN - ELEC 1L103
1/4" = 1'-0"3
ENLARGED POWER PLAN - TR 1L107
1/4" = 1'-0"4
ENLARGED POWER PLAN - TR 1L110
3/32" = 1'-0"5
BLDG. 05 POWER PLAN 4TH FLR - CONCOURSE
(E) DIST BOARD 'D524' (E) XFMR 'T6'
(E) PNL 'R524'
(E) XFMR 'T3'
(E) PNL 'ER525'
(E) PNL 'ELS545'
(E) PNL 'L544'
(E) PNL 'LC544'(E) DIST BOARD '400A DX'
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
05-EP-041
OVERALL FOURTH FLOOR POWER PLAN -
BLDG. 05
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 05 POWER OVERALL PLAN - LEVEL 4
GENERAL NOTES
1. COORDINATE EXACT LOCATION OF MECHANICAL AND TELECOMMUNICATIONS EQUIPMENT
WITH THE CORRESPONDING DISCIPLINE'S DRAWINGS.
2. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
3. REFER TO ASSOCIATED TN SHEET FOR RACK QUANTITIES IN EXISTING AND NEW TR
SPACES.
4. ASSUMED CAPACITY AND LOAD AVAILABLE TO PANELS BEING USED IN SCOPE OF WORK.
CONTRACTOR TO VERIFY SUFFICIENT LOAD IS AVAILABLE PRIOR TO ADDING EQUIPMENT TO
ASSOCIATED PANELS TO AVOID POTENTIAL PANEL OVERLOAD.
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
DN
UP
UP
DN
PMRS SCI EXAM
1M028
PMRS SCI EXAM
1M030
PMRS EXAM
1M036
PMRS EXAM
1M038
PMRS EXAM
1M040
PMRS EXAM
1M037
PMRS EXAM
1M039
PMRS EXAM
1M035
PMRS SCI EXAM
1M031
PMRS SCI EXAM
1M029 CONSULT
1M042
PROS EXAM
1M045
T
1M034
DRESS
1M044
CAST ROOM
1M076
PROS EXAM
1M043
PROS EXAM
1M047
PROS EXAM
1M049
ELEV EQUIP
1M015
MOLD ROOM
1M055
CLEAN LINEN
1M077
RESTR LAB
1M054
DUST ROOM
1M062
FUME ROOM
1M066
MAINT
1M064
LAB
1M056
LAB
1M058 LAB
1M060
WC PARTS
1M069
SEWING RM
1M052
CAD/CAM
1M075
P/O PARTS
1M057
WC REPAIR
1M068
SOIL HOLD
1M071
HK
1M073
SHOE
1M053
WC HOLDING
1M063
TRASH
1M072
TRTMT
1M112
BAR TRTMT
1M111
TRTMT
1M110
MAT AREA
1M114
NURSE STATION
1M033
PT OFFICE
1M137
PT OFFICE
1M142
CONF/ CLASSRM
1M143
RESID
1M135
RESID
1M131
RESID
1M132
RESID
1M129
RESID
1M128
RESID
1M134
RESID
1M130
RESID
1M133
SEC
1M125
COPY/ FAX
1M126
WAITING
1M124
TR
1M115A
1M240
STAFF LCKR
1M146 STAFF LOUNGE
1M147
WOMEN LCKR
1M161
MEN LCKR
1M156
REC OFFICE
1M154
REC OFFICE
1M153
CLEAN
1M160
POOL ROOM
1M162
OT GYM
1M113PT GYM
1M095
LINEN
1M108
WC ALC A
1M067
EQUIP STOR
1M061
MAIL AREA
1M074
TRTMT
1M107
BAR TRTMT
1M106
CERVICAL TRTMT
1M105
REC THER STOR
1M163
SOIL HOLD
1M158
DR
1M032B
DR
1M032A
DR
1M139
DR
1M140
DR
1M141
HK
1M109
MAIN STREET
1M019
HK
1M159
PROS CONF
1M093
AISLE C
1M144
ST
1M050
ELECTRO
1M046
WC ACTIVE
1M065
PROS OFFICE
1M080
CHIEF OFFICE
1M083
PURCH AGNT
1M085GAIT LANE
1M078
PROS OFFICE
1M081
SEC/ WAIT
1M079A
ST
1M121
STOR
1M082
MULTI-PUR RM
1M092
PURCH AGNT
1M087
PURCH AGNT
1M089
PURCH AGNT
1M091
PURCH AGNT
1M084
PURCH AGNT
1M086
COPY/ FAX
1M088
PURCH AGNT
1M090
CORR A
1M026
ST
1M148
NORM ELEC
1M014
EMER ELEC
1M013
NORM ELEC
1M116
POOL EQUIP
1M165
DEHUMIDIFICATION
EQUIP
1M164
FILE ROOM
1M127
SALON
1M024
FEMALE
1M016
MALE
1M017
PT/ OT ADMIN
1M103
UTILITY AREA
1M104
SOIL HOLD
1M097
DRESS
1M098
DRESS
1M099
CARDIO AREA
1M118
BAL QUEST
1M102
WC STOR
1M119A
OT STOR/ PAT PROJ
1M117
T
1M101
SUB WAIT
1M100
PT STOR
1M119
VESTIBULE
1M151
DR
1M138
WAITING
1M007
SERV ELEV LOBBY
1M122
MP-01
1M021A
STAIR M1
1M022
MS-03
1M123
STAIR M2
1M150
PROS REP
1M006
MEDS
1M048
BRAIN TRAIN
1M096
CHUTE ROOM
1M149
LOBBY
1M152
CORR C
1M041
CORR D
1M059
AISLE
1M079
AISLE B
1M051
AISLE A
1M094
AISLE
1M136
CORR
1M010
CORR
1M018
CORR C
1M027
CORR D
1M070
STOR
1M157
RECEP
1M155
CORR A
1M120
T
1M025A
STOR
1M025B
SANCTUARY
1M023
ADMIN WKRM
1M005A
SUNDRY SHOP
1M025
CHECK OUT
1M005B
CHECK OUT
1M005D
STOR
1M023A
RECEPT
1M004
FAMILY T
1M011
ST
1M145
SECUR DESK
1M003
ENTRY
1M002
VESTIBULE
1M001
WC ALC
1M012
MP-02
1M021B
PUB ELEV LOBBY
1M020
LVSR
1M115
STAFF COURT
1M147A
PASS
1M005C
CORR A
1M151A
06-ED-011
06-ED-011
06-ED-011
06-ED-011
(E) PNL 'R62123'
(E) PNL 'R62113'
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
(E) PNL 'ECR62131A'
(E) PNL 'ECR62131B'
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(X)ECR62131A-5
(X)ECR62131A-7
(X)ECR62131A-9
(X)ECR62131A-11
(X)ECR62131A-15
(X)ECR62131A-6
(X)ECR62131A-8
(X)ECR62131A-10
(X)ECR62131A-17
(X)ECR62131-13
(X)ECR62131A-21,23
(X)ECR62131A-12
(X)ECR62131A-14
(X)ECR62131A-16
(X)ECR62131A-22
(X)ECR62131A-18
(X)ECR62131A-20
TR
1M115A
1M240
MOUNTED ON
CABLE TRAY
(TYP.)
(E) DIST BOARD 'D6212'
(E) XFMR 'T7'
(E) PNL 'D6412'
(E) PNL 'L6412' (E) PNL 'LC6412'
(E) PNL 'ECR62121'
(E) PNL 'R62122B'
(E) PNL 'R62122A'
(E) PNL 'R62121B'
(E) PNL 'R62121A'
NORM ELEC
1M116
(E) PNL 'ECL6411'
(E) PNL 'ECR62111'
(E) XFMR 'T5'
EMER ELEC
1M013
(E) XFMR 'T8'
(E) DIST BOARD 'D6211'
(E) PNL 'R62112A'
(E) PNL 'R62112B'(E) PNL 'R62111A'
(E) PNL 'R62111B'
(E) PNL 'LC6411'
(E) PNL 'L6411'
(E) DIST BOARD 'D6411'
NORM ELEC
1M014
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
06-ED-011
OVERALL FIRST FLOOR POWER
DEMOLITION PLAN - BLDG. 06
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 06 POWER OVERALL DEMOLITION PLAN - LEVEL 1
1/4" = 1'-0"2
ENLARGED POWER DEMO PLAN - TR 1M240
1/4" = 1'-0"3
ENLARGED POWER DEMO PLAN - NORM 1M116
1/4" = 1'-0"5
ENLARGED POWER DEMO PLAN - EMER 1M013
1/4" = 1'-0"4
ENLARGED POWER DEMO PLAN - NORM 1M014
DEMOLITION GENERAL NOTES
1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE ALL INTERRUPTIONS SERVICES WITH THE COR PRIOR TO
INITIATION OF WORK. NO DEMOLITION SHALL OCCUR UNTIL AFTER THE NEW OR
REPLACEMENT SYSTEMS ARE IN PLACE AND READY FOR CUT OVER.
3. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
4. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
5. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
6. PARTICULAR ATTENTION SHALL BE GIVEN TO THE PROTECTION OF EXISTING STRUCTURE
AND FINISHES TO PREVENT ANY DAMAGE OF EXISTING FINISHES. ANY ACCIDENTAL DAMAGE
INCURRED TO EXISTING CONDITIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO REPAIR OR CORRECT.
7. CONTRACTOR SHALL CONFIRM EXISTING CIRCUITING TO UPS EQUIPMENT AND RACK
MOUNTED RECEPTACLES IN EXISTING TELECOMMUNICATION ROOMS PRIOR TO
DEMOLITION. ANY EXISTING FEEDERS NOT SUPPLYING UPS EQUIPMENT OR RACK MOUNTED
RECEPTACLES TO REMAIN.
8. EXISTING RACK MOUNTED RECEPTACLES BEING UTILIZED TO REMAIN. CONTRACTOR TO
VERIFY RECEPTACLE UTLIZATION PRIOR TO DEMOLITION.
PLAN NOTES
1 EXISTING ELECTRICAL RECEPTACLES TO BE REMOVED. CONTRACTOR TO REMOVE
EXISTING CONDUIT AND CONDUCTORS BACK TO SOURCE.
2 EXISTING ELECTRICAL RECEPTACLE TO REMAIN.
3 EXISTING ELECTRICAL PANEL TO REMAIN.
4 EXISTING UPS TO BE REMOVED. CONTRACTOR TO REMOVE EXISTING CONDUIT,
CONDUCTORS, AND JUNCTION BOXES BACK TO SOURCE.
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
DN
UP
UP
DN
TR
2M066A
2M252
PAT
2M021
BAR PAT
2M019
PAT
2M108
MEDS
2M016
PANTRY
2M004
MULTI-PUR
2M003
EQUIP
2M034
QUIET/ DEN
2M032
CARE TEAM
2M061
BAR PAT
2M099
ISO PAT
2M020
T
2M021A T
2M022A
PAT
2M022
PAT
2M023
PAT
2M024
PAT
2M025
PAT
2M026
PAT
2M115
PAT
2M114
PAT
2M112
PAT
2M111 PAT
2M110
T
2M108A
CARE TEAM
2M065
BAR T
2M099A
ISO PAT
2M101
QUIET/ DEN
2M121
LAUN
2M012
VT
2M015
NOUR
2M030
VEST
2M031
CORR E
2M018
VEST
2M120
LIVING/DINING
2M116
CORR E
2M107
ACAD WKRM
2M062
LAUN
2M037
QUIET/ DEN
2M057
QUIET/ DEN
2M094
ACAD WKRM
2M064
PHY THER
2M128
CONF/ CLASSRM
2M142
SOC WORK
2M137
DIETITIAN
2M136
MDS COORD
2M139
PANTRY
2M127A
NURSE MAN
2M138
MED DIR
2M132
THERAPIST
2M128A
VEST
2M093
LIVING/DINING
2M052
VEST
2M056
HK
2M055
PAT
2M046
CORR E
2M043
CLEAN LINEN
2M010A
LIVING/DINING
2M090
SOIL
2M008
MEDS
2M041
NOUR
2M053
VT
2M054
CLEAN LINEN
2M035A
LIVING/DINING
2M029
CORR B
2M001
CORR E
2M079
WC ALC B
2M059
WC ALC B
2M125
CORR B
2M063
T
2M024A
T
2M023A
T
2M026A
T
2M025A
T
2M028A
T
2M027A
PAT
2M027
PAT
2M028
PAT
2M113
T
2M114A
T
2M115A
T
2M112A
T
2M113A
T
2M110A
T
2M111A
T
2M020A
BAR PAT
2M080
BAR PAT
2M044
PAT
2M040
ISO PAT
2M045
T
2M081A
ISO PAT
2M081
PAT
2M082
PAT
2M083
PAT
2M084
PAT
2M085
PAT
2M051
T
2M088A
PAT
2M050
PAT
2M049
PAT
2M048
PAT
2M047
BAR T
2M044A
BAR T
2M080A
T
2M040A
PAT
2M038
T
2M083A
T
2M082A
T
2M085A
T
2M084A
T
2M087A
T
2M086A
PAT
2M086
PAT
2M087
PAT
2M088
T
2M050A T
2M051A
T
2M048A
T
2M049AT
2M046A
T
2M047A
VT
2M118
HK
2M103
SOIL
2M070
MEDS
2M106
NOUR
2M117
EMER ELEC
2M119
CLEAN LINEN
2M097A
VT
2M092
MEDS
2M078
LAUN
2M074A
NOUR
2M091 CLEAN LINEN
2M074
HK
2M073
PAT
2M109
T
2M126
HK
2M011
T
2M109A
LAUN
2M102
NORM ELEC
2M007
EMER ELEC
2M009
CARE GIVER
2M014
CG
2M039
T
2M045A
PAT
2M089
T
2M089A
CG
2M076
ASST MAN
2M140
STOR
2M134A
CG
2M104
BAR T
2M019A
EXTERIOR COURTYARD
2M033
EXTERIOR COURTYARD
2M122
EXTERIOR COURTYARD
2M058
EXTERIOR COURTYARD
2M095
RECEP
2M002
ST
2M098
ST
2M017
MP-01
2M005A
STAIR M1
2M006
STAIR M2
2M124
SERV ELEV LOBBY
2M067
MS-03
2M068
CLEAN
2M013
EQUIP
2M096
ST
2M075
CHUTE ROOM
2M069
CLEAN
2M100
CLEAN
2M072
CORR B
2M123
VT
2M002A
COPY/ FAX
2M133
FOOD PREP
2M060
FOOD PREP
2M030A
LOUNGE
2M143
MULTI-PUR
2M127
ST
2M130
CORR G
2M129
DR OFFICE 1
2M141
DR OFFICE 2
2M135
T
2M101A
T
2M038A
CLEAN
2M036
ST
2M042
CORR F
2M010
CORR F
2M097
CORR F
2M071
CORR F
2M035
MP-02
2M005B
LVSR
2M066
OUT TER
2M143A
STOR
2M131
SEC
2M134
06-ED-021
06-ED-021
06-ED-021
06-ED-021
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
(E) PNL 'ECR62231B'
(E) PNL 'ECR62231A'
TR
2M066A
2M252
MOUNTED ON
CABLE TRAY
(TYP.)
(X)ECR62231A-29
(E)UNLABELED
(X)ECR62231A-21,23
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(X)ECR62231A-20
(X)ECR62231A-18
(X)ECR62231A-16
(X)ECR62231A-14
(X)ECR62231A-12
(X)ECR62231A-10
(X)ECR62231A-8
(X)ECR62231A-6,19,17,15,13,11,7,5
(E) PNL 'ECR62221B'
(E) PNL 'ECR62221A'
(E) PNL 'R62222B'
(E) PNL 'R62222A'
(E) PNL 'R62221B'
(E) PNL 'R62221A'
(E) PNL 'LC6422' (E) PNL 'L6422'
(E) DIST BOARD 'D6422'
(E) DIST BOARD 'D6222'
(E) XFMR 'T6'
(E) PNL 'R62223'
(E) PNL 'EQR622'
EMER ELEC
2M119
(E) PNL 'ECR62211A'
(E) PNL 'ECR62211B'
(E) PNL 'ELSR6221' (E) PNL 'ELSL6421'
(E) PNL 'ECL6421'
(E) PNL 'ECRD6221'
(E) XFMR 'T6'
EMER ELEC
2M009
(E) PNL 'LC6421'
(E) PNL 'L6421'
(E) DIST BOARD 'D6421' (E) XFMR 'T7'
(E) PNL 'R62213'
(E) DIST BOARD 'D6221'
(E) PNL 'R62212B'
(E) PNL 'R62212A'(E) PNL 'R62211B'
(E) PNL 'R62211A'
NORM ELEC
2M007
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
06-ED-021
OVERALL SECOND FLOOR POWER
DEMOLITION PLAN - BLDG. 06
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 06 POWER OVERALL DEMOLITION PLAN - LEVEL 2
1/4" = 1'-0"2
ENLARGED POWER DEMO PLAN - TR 2M252
1/4" = 1'-0"3
ENLARGED POWER DEMO PLAN - EMER 2M119
1/4" = 1'-0"5
ENLARGED POWER DEMO PLAN - EMER 2M009
1/4" = 1'-0"4
ENLARGED POWER DEMO PLAN - NORM 2M007
DEMOLITION GENERAL NOTES
1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE ALL INTERRUPTIONS SERVICES WITH THE COR PRIOR TO
INITIATION OF WORK. NO DEMOLITION SHALL OCCUR UNTIL AFTER THE NEW OR
REPLACEMENT SYSTEMS ARE IN PLACE AND READY FOR CUT OVER.
3. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
4. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
5. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
6. PARTICULAR ATTENTION SHALL BE GIVEN TO THE PROTECTION OF EXISTING STRUCTURE
AND FINISHES TO PREVENT ANY DAMAGE OF EXISTING FINISHES. ANY ACCIDENTAL DAMAGE
INCURRED TO EXISTING CONDITIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO REPAIR OR CORRECT.
7. CONTRACTOR SHALL CONFIRM EXISTING CIRCUITING TO UPS EQUIPMENT AND RACK
MOUNTED RECEPTACLES IN EXISTING TELECOMMUNICATION ROOMS PRIOR TO
DEMOLITION. ANY EXISTING FEEDERS NOT SUPPLYING UPS EQUIPMENT OR RACK MOUNTED
RECEPTACLES TO REMAIN.
8. EXISTING RACK MOUNTED RECEPTACLES BEING UTILIZED TO REMAIN. CONTRACTOR TO
VERIFY RECEPTACLE UTLIZATION PRIOR TO DEMOLITION.
PLAN NOTES
1 EXISTING ELECTRICAL RECEPTACLES TO BE REMOVED. CONTRACTOR TO REMOVE
EXISTING CONDUIT AND CONDUCTORS BACK TO SOURCE.
2 EXISTING ELECTRICAL RECEPTACLE TO REMAIN.
3 EXISTING ELECTRICAL PANEL TO REMAIN.
4 EXISTING UPS TO BE REMOVED. CONTRACTOR TO REMOVE EXISTING CONDUIT,
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
DN
UP
UP
DN
ON CALL ROOM
3M079
MULTI-PUR
3M074
PANTRY
3M074A
MECH ROOM
3M081
CORR B
3M001
LOUNGE/ LOCKERS
3M078
CORR
3M071
OUTDOOR TERRACE
3M037
ASST. MANG.
3M073
PANTRY
3M004
MULTI-PUR
3M003
QUIET/ DEN
3M034
CARE TEAM
3M036
BAR T
3M021A
QUIET/ DEN
3M069
VEST
3M033
CORR
3M020
VEST
3M068
LIVING/DINING
3M064
CORR
3M055
LIVING/DINING
3M031
HK
3M051
SOIL
3M010
NORM ELEC
3M009
EMER ELEC
3M011 TR
3M040A
3M111
T
3M076
MEDS
3M018
EQUIP
3M044
LAUN
3M014
VT
3M017
NOUR
3M032
CLEAN LINEN
3M012A
HK
3M013
CG
3M016
PAT
3M023
BAR PAT
3M021
PAT
3M056ISO PAT
3M022
T
3M023A
T
3M024A
PAT
3M024
PAT
3M025
PAT
3M026
PAT
3M027
PAT
3M028
PAT
3M063
PAT
3M062
PAT
3M060
PAT
3M059
PAT
3M058
T
3M056A
T
3M026A
T
3M025A
T
3M028A
T
3M027A
T
3M030A
T
3M029A
PAT
3M029
PAT
3M030
PAT
3M061
T
3M062A
T
3M063A
T
3M060A
T
3M061A
T
3M058A
T
3M059A
T
3M022A
PAT
3M057
T
3M057A
ACAD WKRM
3M039
VT
3M066
MEDS
3M054
NOUR
3M065
NORM ELEC
3M067
CLEAN LINEN
3M045A
LAUN
3M050
CG
3M052 T
3M049A
BAR PAT
3M047
BAR T
3M047A
ISO PAT
3M049
SERV ELEV LOBBY
3M041
ST
3M046
ST
3M019
STAIR M1
3M006
MP-01
3M005A STAIR M2
3M072
MS-03
3M042
CLEAN
3M015
T/SHWR
3M079A
CLEAN
3M048
WC ALC B
3M007
EQUIP
3M008
CHUTE ROOM
3M043
FOOD PREP
3M032A
VT
3M002A
CORR F
3M012
CORR F
3M045
OUTDOOR TERRACE
3M035
OUTDOOR TERRACE
3M070
MP-02
3M005B
LVSR
3M040
ST
3M080
WC ALC B
3M075
PASS
3M077
TR
3M104
3M104
06-ED-031
06-ED-031
06-ED-031
06-ED-031
06-ED-031
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
(E) PNL 'ECR62331'
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED (E)UNLABELED
(E)UNLABELED
MOUNTED ON
CABLE TRAY
(TYP.)
(X)ECR62331-1,3
(X)ECR62331-19
TR
3M040A
3M111
(X)ECR62331-5
(X)ECR62331-7
(X)ECR62331-9
(X)ECR62331-11
(X)ECR62331-13
(X)ECR62331-17
(X)ECR62331-15
(E) DIST BOARD 'D6232'
(E) XFMR 'T5'
(E) DIST BOARD 'D6432'
(E) PNL 'L6432'(E) PNL 'LC6432'
(E) PNL 'R62322A'
(E) PNL 'R62322B'
(E) PNL 'R62321A'
(E) PNL 'R62321B'
(E) PNL 'ECR62321'
NORM ELEC
3M067(E) PNL 'ECL6431'
(E) PNL 'ECR62311'
(E) XFMR 'T5'
EMER ELEC
3M011
(E) PNL 'LC6431'
(E) PNL 'L6431'
(E) DIST BOARD 'D6431' (E) XFMR 'T6'
(E) DIST BOARD 'D6231'
(E) PNL 'R62312A'
(E) PNL 'R62312B'(E) PNL 'R62311A'
(E) PNL 'R62311B'
NORM ELEC
3M009
(E) PNL 'ECR62312'
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(X)ECR62312-3
MOUNTED ON
CABLE TRAY
(TYP.)
(X)UNLABELED
TR
3M104
3M104
4(X)ECR62312-2
(X)ECR62312-5
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
06-ED-031
OVERALL THIRD FLOOR POWER
DEMOLITION PLAN - BLDG. 06
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 06 POWER OVERALL DEMOLITION PLAN - LEVEL 3
1/4" = 1'-0"2
ENLARGED POWER DEMO PLAN - TR 3M252
1/4" = 1'-0"3
ENLARGED POWER DEMO PLAN - NORM 3M067
1/4" = 1'-0"4
ENLARGED POWER DEMO PLAN - EMER 3M011
1/4" = 1'-0"5
ENLARGED POWER DEMO PLAN - NORM 3M009
1/4" = 1'-0"6
ENLARGED POWER DEMO PLAN - TR 3M104
DEMOLITION GENERAL NOTES
1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE ALL INTERRUPTIONS SERVICES WITH THE COR PRIOR TO
INITIATION OF WORK. NO DEMOLITION SHALL OCCUR UNTIL AFTER THE NEW OR
REPLACEMENT SYSTEMS ARE IN PLACE AND READY FOR CUT OVER.
3. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
4. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
5. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
6. PARTICULAR ATTENTION SHALL BE GIVEN TO THE PROTECTION OF EXISTING STRUCTURE
AND FINISHES TO PREVENT ANY DAMAGE OF EXISTING FINISHES. ANY ACCIDENTAL DAMAGE
INCURRED TO EXISTING CONDITIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO REPAIR OR CORRECT.
7. CONTRACTOR SHALL CONFIRM EXISTING CIRCUITING TO UPS EQUIPMENT AND RACK
MOUNTED RECEPTACLES IN EXISTING TELECOMMUNICATION ROOMS PRIOR TO
DEMOLITION. ANY EXISTING FEEDERS NOT SUPPLYING UPS EQUIPMENT OR RACK MOUNTED
RECEPTACLES TO REMAIN.
8. EXISTING RACK MOUNTED RECEPTACLES BEING UTILIZED TO REMAIN. CONTRACTOR TO
VERIFY RECEPTACLE UTLIZATION PRIOR TO DEMOLITION.
PLAN NOTES
1 EXISTING ELECTRICAL RECEPTACLES TO BE REMOVED. CONTRACTOR TO REMOVE
EXISTING CONDUIT AND CONDUCTORS BACK TO SOURCE.
2 EXISTING ELECTRICAL RECEPTACLE TO REMAIN.
3 EXISTING ELECTRICAL PANEL TO REMAIN.
4 EXISTING UPS TO BE REMOVED. CONTRACTOR TO REMOVE EXISTING CONDUIT,
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
DN
UP
CB
CB
CB
CB
CB
CB
CB
CB
EMER ELEC ROOM
4M009
WET MECH
4M010
ELEC SWITCHGEAR
4M003
CENTRAL STOR
4M005
HK STOR
4M014
CART STAGING
4M008
FOOD PREP
4M012
RESIDENT STOR
4M002
CLEAN STAG
4M011
TR
4M015A
4M113
CORR B
4M001
CORR B
4M006
MS-03
4M013
STAIR M2
4M004
VEST
4M004A
LVSR
4M015
CHUTE
4M007
GENERAL STORAGE
4M016
(E)UNIT SUBSTATION
USS06
(E)UNIT SUBSTATION
EUSS06
(E) CB '06-5M2-S1'
(E) CB '06-4M2-S2'
(E) CB '06-4M2-S16'
(E) CB '06-4M2-S15'
(E) CB '06-4M1-S13'
(E) CB '06-4M1-S14'
(E) CB '06-4M2-S3'
06-ED-041
(E) PNL 'EQP6441B'
(E) PNL 'EQP6441A'
(E) DIST BOARD 'EQD6441'
(E) PNL 'EC'
(E) PNL 'ESS'
(E) PNL 'ELS'
(E) PNL 'EQR624'
(E) XFMR 'T4'
(E) XFMR 'T3'
(E) DIST BOARD 'ECD6441'
(E) XFMR 'T5-1'
(E) XFMR 'T3'
(E) PNL 'ELSR6241' (E) XFMR 'T5-1'
(E) DIST BOARD 'ELSD6441'
(E) DIST BOARD 'D6441'(E) DIST BOARD 'D6442'
(E) DIST BOARD 'D6443'
(E) PNL 'P6442'
(E) PNL 'L6442'
(E) PNL 'LC6442'
(E) XFMR 'T4'
(E) PNL 'R62421A'
(E) PNL 'R62421B'
(E) CB 'UNLABELED'
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
(E) PNL 'ECR62421'
(E)UNLABELED
(E)UNLABELED (E)UNLABELED
(E)UNLABELED
MOUNTED ON
CABLE TRAY
(TYP.)
(X)ECR62421-7(X)ECR62421-2,4
TR
4M015A
4M113
(X)ECR62421-5
(X)ECR62421-9
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
06-ED-041
OVERALL FOURTH FLOOR POWER
DEMOLITION PLAN - BLDG. 06
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 06 POWER OVERALL DEMOLITION PLAN - LEVEL 4
1/4" = 1'-0"2
ENLARGED POWER DEMO PLAN - TR 4M115
DEMOLITION GENERAL NOTES
1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE ALL INTERRUPTIONS SERVICES WITH THE COR PRIOR TO
INITIATION OF WORK. NO DEMOLITION SHALL OCCUR UNTIL AFTER THE NEW OR
REPLACEMENT SYSTEMS ARE IN PLACE AND READY FOR CUT OVER.
3. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
4. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
5. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
6. PARTICULAR ATTENTION SHALL BE GIVEN TO THE PROTECTION OF EXISTING STRUCTURE
AND FINISHES TO PREVENT ANY DAMAGE OF EXISTING FINISHES. ANY ACCIDENTAL DAMAGE
INCURRED TO EXISTING CONDITIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO REPAIR OR CORRECT.
7. CONTRACTOR SHALL CONFIRM EXISTING CIRCUITING TO UPS EQUIPMENT AND RACK
MOUNTED RECEPTACLES IN EXISTING TELECOMMUNICATION ROOMS PRIOR TO
DEMOLITION. ANY EXISTING FEEDERS NOT SUPPLYING UPS EQUIPMENT OR RACK MOUNTED
RECEPTACLES TO REMAIN.
8. EXISTING RACK MOUNTED RECEPTACLES BEING UTILIZED TO REMAIN. CONTRACTOR TO
VERIFY RECEPTACLE UTLIZATION PRIOR TO DEMOLITION.
PLAN NOTES
1 EXISTING ELECTRICAL RECEPTACLES TO BE REMOVED. CONTRACTOR TO REMOVE
EXISTING CONDUIT AND CONDUCTORS BACK TO SOURCE.
2 EXISTING ELECTRICAL RECEPTACLE TO REMAIN.
3 EXISTING ELECTRICAL PANEL TO REMAIN.
4 EXISTING UPS TO BE REMOVED. CONTRACTOR TO REMOVE EXISTING CONDUIT,
UP
DN
F
PMRS SCI EXAM
1M028
PMRS SCI EXAM
1M030
PMRS EXAM
1M036
PMRS EXAM
1M038
PMRS EXAM
1M040
PMRS EXAM
1M037
PMRS EXAM
1M039
PMRS EXAM
1M035
PMRS SCI EXAM
1M031
PMRS SCI EXAM
1M029 CONSULT
1M042
PROS EXAM
1M045
T
1M034
DRESS
1M044
CAST ROOM
1M076
PROS EXAM
1M043
PROS EXAM
1M047
PROS EXAM
1M049
ELEV EQUIP
1M015
MOLD ROOM
1M055
CLEAN LINEN
1M077
RESTR LAB
1M054
DUST ROOM
1M062
FUME ROOM
1M066
MAINT
1M064
LAB
1M056
LAB
1M058 LAB
1M060
WC PARTS
1M069
SEWING RM
1M052
CAD/CAM
1M075
P/O PARTS
1M057
WC REPAIR
1M068
SOIL HOLD
1M071
HK
1M073
SHOE
1M053
WC HOLDING
1M063
TRASH
1M072
TRTMT
1M112
BAR TRTMT
1M111
TRTMT
1M110
MAT AREA
1M114
NURSE STATION
1M033
PT OFFICE
1M137
PT OFFICE
1M142
CONF/ CLASSRM
1M143
RESID
1M135
RESID
1M131
RESID
1M132
RESID
1M129
RESID
1M128
RESID
1M134
RESID
1M130
RESID
1M133
SEC
1M125
COPY/ FAX
1M126
WAITING
1M124
TR
1M115A
1M240
STAFF LCKR
1M146 STAFF LOUNGE
1M147
WOMEN LCKR
1M161
MEN LCKR
1M156
REC OFFICE
1M154
REC OFFICE
1M153
CLEAN
1M160
POOL ROOM
1M162
OT GYM
1M113PT GYM
1M095
LINEN
1M108
WC ALC A
1M067
EQUIP STOR
1M061
MAIL AREA
1M074
TRTMT
1M107
BAR TRTMT
1M106
CERVICAL TRTMT
1M105
REC THER STOR
1M163
SOIL HOLD
1M158
DR
1M032B
DR
1M032A
DR
1M139
DR
1M140
DR
1M141
HK
1M109
MAIN STREET
1M019
HK
1M159
PROS CONF
1M093
AISLE C
1M144
ST
1M050
ELECTRO
1M046
WC ACTIVE
1M065
PROS OFFICE
1M080
CHIEF OFFICE
1M083
PURCH AGNT
1M085GAIT LANE
1M078
PROS OFFICE
1M081
SEC/ WAIT
1M079A
ST
1M121
STOR
1M082
MULTI-PUR RM
1M092
PURCH AGNT
1M087
PURCH AGNT
1M089
PURCH AGNT
1M091
PURCH AGNT
1M084
PURCH AGNT
1M086
COPY/ FAX
1M088
PURCH AGNT
1M090
CORR A
1M026
ST
1M148
NORM ELEC
1M014
EMER ELEC
1M013
NORM ELEC
1M116
POOL EQUIP
1M165
DEHUMIDIFICATION
EQUIP
1M164
FILE ROOM
1M127
SALON
1M024
FEMALE
1M016
MALE
1M017
PT/ OT ADMIN
1M103
UTILITY AREA
1M104
SOIL HOLD
1M097
DRESS
1M098
DRESS
1M099
CARDIO AREA
1M118
BAL QUEST
1M102
WC STOR
1M119A
OT STOR/ PAT PROJ
1M117
T
1M101
SUB WAIT
1M100
PT STOR
1M119
VESTIBULE
1M151
DR
1M138
WAITING
1M007
SERV ELEV LOBBY
1M122
MP-01
1M021A
STAIR M1
1M022
MS-03
1M123
STAIR M2
1M150
PROS REP
1M006
MEDS
1M048
BRAIN TRAIN
1M096
CHUTE ROOM
1M149
LOBBY
1M152
CORR C
1M041
CORR D
1M059
AISLE
1M079
AISLE B
1M051
AISLE A
1M094
AISLE
1M136
CORR
1M010
CORR
1M018
CORR C
1M027
CORR D
1M070
STOR
1M157
RECEP
1M155
CORR A
1M120
T
1M025A
STOR
1M025B
SANCTUARY
1M023
ADMIN WKRM
1M005A
SUNDRY SHOP
1M025
CHECK OUT
1M005B
CHECK OUT
1M005D
STOR
1M023A
RECEPT
1M004
FAMILY T
1M011
ST
1M145
SECUR DESK
1M003
ENTRY
1M002
VESTIBULE
1M001
WC ALC
1M012
MP-02
1M021B
PUB ELEV LOBBY
1M020
LVSR
1M115
STAFF COURT
1M147A
PASS
1M005C
CORR A
1M151A
(E) PNL 'R62113'
(E) PNL 'R62123'
06-EP-011
06-EP-011
06-EP-011
06-EP-011
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
(E) PNL 'ECR62131A'
(E) PNL 'ECR62131B'
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
(E)UNLABELED
TR
1M115A
1M240
R62112B-37,39,41
ECR62131A-1,3,5
R62112B-38,40,42
ECR62131A-2,4,6
60AS
60AF
(E) PNL 'D6212'
(E) XFMR 'T7'
(E) PNL 'D6412'
(E) PNL 'L6412' (E) PNL 'LC6412'
(E) PNL 'ECR62121'
(E) PNL 'R62122B'
(E) PNL 'R62122A'
(E) PNL 'R62121B'
(E) PNL 'R62121A'
NORM ELEC
1M116
NORM ELEC
1M014
(E) XFMR 'T8'
(E) PNL 'D6211'
(E) PNL 'R62112A'(E) PNL 'R62111B'
(E) PNL 'LC6411'
(E) PNL 'L6411'
(E) PNL 'D6411'
(E) PNL 'R62111A'
(E) PNL 'R62112B'
(E) XFMR 'T5'
(E) PNL 'ECR62111'
(E) PNL 'ECL6411'
EMER ELEC
1M013
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
06-EP-011
OVERALL FIRST FLOOR POWER PLAN -
BLDG. 06
MER AJW
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
3/32" = 1'-0"1
BLDG. 06 POWER OVERALL PLAN - LEVEL 1
GENERAL NOTES
1. COORDINATE EXACT LOCATION OF MECHANICAL AND TELECOMMUNICATIONS EQUIPMENT
WITH THE CORRESPONDING DISCIPLINE'S DRAWINGS.
2. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
3. REFER TO ASSOCIATED TN SHEET FOR RACK QUANTITIES IN EXISTING AND NEW TR
SPACES.
4. ASSUMED CAPACITY AND LOAD AVAILABLE TO PANELS BEING USED IN SCOPE OF WORK.
CONTRACTOR TO VERIFY SUFFICIENT LOAD IS AVAILABLE PRIOR TO ADDING EQUIPMENT TO
ASSOCIATED PANELS TO AVOID POTENTIAL PANEL OVERLOAD.
PLAN NOTES
1 CONTRACTOR TO PROVIDE NEW 208V, 60A, 3-PHASE POWER TERMINATING IN HARD-WIRED
JUNCTION BOX FOR NEW RACK POWER. JUNCTION BOX TO BE MOUNTED DIRECTLY ON
CABLE TRAY. REFER TO ELECTRICAL FEEDER SCHEDULE ON 00-EG-001 FOR CONDUIT AND
CONDUCTOR SIZING REQUIREMENTS.
2 CONTRACTOR TO PROVIDE NEW L21-20R RECEPTACLE FOR NEW RACK POWER.
RECEPTACLE TO BE MOUNTED DIRECTLY ON CABLE TRAY. PROVIDE 3#12 PHASE
CONDUCTORS, 1#12 NEUTRAL & 1#12 GROUND. ROUTE CONDUCTORS IN 3/4" CONDUIT.
1/4" = 1'-0"2
ENLARGED POWER PLAN - TR 1M240
1/4" = 1'-0"3
ENLARGED POWER PLAN - NORM 1M116
1/4" = 1'-0"4
ENLARGED POWER PLAN - NORM 1M014
1/4" = 1'-0"5
ENLARGED POWER PLAN - EMER 1M013
UP
DN
F
TR
2M066A
2M252
PAT
2M021
BAR PAT
2M019
PAT
2M108
MEDS
2M016
PANTRY
2M004
MULTI-PUR
2M003
EQUIP
2M034
QUIET/ DEN
2M032
CARE TEAM
2M061
BAR PAT
2M099
ISO PAT
2M020
T
2M021A T
2M022A
PAT
2M022
PAT
2M023
PAT
2M024
PAT
2M025
PAT
2M026
PAT
2M115
PAT
2M114
PAT
2M112
PAT
2M111 PAT
2M110
T
2M108A
CARE TEAM
2M065
BAR T
2M099A
ISO PAT
2M101
QUIET/ DEN
2M121
LAUN
2M012
VT
2M015
NOUR
2M030
VEST
2M031
CORR E
2M018
VEST
2M120
LIVING/DINING
2M116
CORR E
2M107
ACAD WKRM
2M062
LAUN
2M037
QUIET/ DEN
2M057
QUIET/ DEN
2M094
ACAD WKRM
2M064
PHY THER
2M128
CONF/ CLASSRM
2M142
SOC WORK
2M137
DIETITIAN
2M136
MDS COORD
2M139
PANTRY
2M127A
NURSE MAN
2M138
MED DIR
2M132
THERAPIST
2M128A
VEST
2M093
LIVING/DINING
2M052
VEST
2M056
HK
2M055
PAT
2M046
CORR E
2M043
CLEAN LINEN
2M010A
LIVING/DINING
2M090
SOIL
2M008
MEDS
2M041
NOUR
2M053
VT
2M054
CLEAN LINEN
2M035A
LIVING/DINING
2M029
CORR B
2M001
CORR E
2M079
WC ALC B
2M059
WC ALC B
2M125
CORR B
2M063
T
2M024A
T
2M023A
T
2M026A
T
2M025A
T
2M028A
T
2M027A
PAT
2M027
PAT
2M028
PAT
2M113
T
2M114A
T
2M115A
T
2M112A
T
2M113A
T
2M110A
T
2M111A
T
2M020A
BAR PAT
2M080
BAR PAT
2M044
PAT
2M040
ISO PAT
2M045
T
2M081A
ISO PAT
2M081
PAT
2M082
PAT
2M083
PAT
2M084
PAT
2M085
PAT
2M051
T
2M088A
PAT
2M050
PAT
2M049
PAT
2M048
PAT
2M047
BAR T
2M044A
BAR T
2M080A
T
2M040A
PAT
2…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .