2.4 - Drawings 04 of 17 - 01-AE-011 to 02-AE-052.pdf

PDF 18 MB Posted

Attached to
NOLA EHRM Infrastructure Upgrades Construction - New Orleans, LA 629-22-700
Solicitation number
36C77623B0038
Issued by

About this file

This document provides details on a federal contract opportunity for infrastructure upgrades at a Veterans Affairs facility in New Orleans, Louisiana. The solicitation number is 36C77623B0038 and is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The opportunity type is a solicitation for construction services related to electrical, heating, ventilation and air conditioning infrastructure upgrades at the New Orleans VA medical center. The solicitation includes 17 drawings related to the project scope across various buildings. Responses are due based on the standard solicitation timeline and award will be made to a single contractor to complete the upgrades by the specified deadline.

View the file

Other files

File Type Posted
36C77623B0038 0007.pdf PDF
Tech Questions Tracker - NOLA - 8-25-23.pdf PDF
Brand Name JA - NOLA EHRM.pdf PDF
Tech Questions Tracker - NOLA - 8-23-23.pdf PDF
36C77623B0038 0006.pdf PDF
36C77623B0038 0005.pdf PDF
Tech Questions Tracker - NOLA - 8-9-23.pdf PDF
36C77623B0038 0004.pdf PDF
Specs and Drawings - NOLA EHRM - Addendum No 2.pdf PDF
36C77623B0038 0003.pdf PDF
Specs and Drawings - NOLA EHRM - Addendum No 1.pdf PDF
36C77623B0038 0002.pdf PDF
NOLA EHRM Site Visit Sign-In Sheet 19 July 23.pdf PDF
36C77623B0038 0001.pdf PDF
Site Visit Instructions.pdf PDF
2.12 - Drawings 12 of 17 - 00-EG-001 to 02-ED-051.pdf PDF
2.2 - Drawings 02 of 17 - 000-AJ-601 to 000-AJ-606.pdf PDF
2.17 - Drawings 17 of 17 - 04-FP-100 to 11-FP-110.pdf PDF
1 - Specifications.pdf PDF
2.10 - Drawings 10 of 17 - 04-TD-011 to 08-TD-051.pdf PDF
2.13 - Drawings 13 of 17 - 02-EP-011 to 03-EP-071.pdf PDF
2.5 - Drawings 05 of 17 - 02-AC-011 to 03-AE-071.pdf PDF
2.16 - Drawings 16 of 17 - 00-FP-000 to 03-FP-111.pdf PDF
2.11 - Drawings 11 of 17 - 08-TN-011 to 00-TJ-028.pdf PDF
2.9 - Drawings 09 of 17 - 02-TN-011 to 03-TN-071.pdf PDF
IFB 36C77623B0038 - 6-29-23.pdf PDF
6 - Contractor Safety and Environmental Record.docx DOCX document
4 - DBA Wage Rates - Orleans County - 06-16-23.pdf PDF
2.1 - Drawings 01 of 17 - GI001 to GI003.pdf PDF
2.6 - Drawings 06 of 17 - 03-AC-011 to 11-AE-011.pdf PDF
2.8 - Drawings 08 of 17 - 00-TG-001 to 02-TD-052.pdf PDF
2.14 - Drawings 14 of 17 - 04-ED-011 to 10-EP-011.pdf PDF
2.15 - Drawings 15 of 17 - 01-EJ-001 to 00-EJ-026.pdf PDF
2.7 - Drawings 07 of 17 - 00-MK-001 to 10-MJ-011.pdf PDF
3 - HVAC Load Calculations.pdf PDF
5 - Limitations on Subcontracting - Construction.docx DOCX document
2.3 - Drawings 03 of 17 - 00-CG-001 to CJ-A102.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

UP

RE

TH

TH

RE

RE

TH

TH

RE

RE

RE

RE

RE

RE

RE

RE

RE

CR

OC

O

CC

R

CHF (OC)

1C220

A CHF (OC)

1C222

SECY (OC)

1B208

ITAC (OC)

1B141

CS (OC)

1B139

OFF CHF (FS)

1B151

BA (OC)

1C224

ADM (OC)

1B140

MA ASST (OC)

1C226

CUB (FS)

1B191C

CUB (FS)

1B191B

CUB (FS)

1B193A

CUB (FS)

1B192A

CUB (FS)

1B192B

MEDIA (FS)

1B154

OFF A CHF (FS)

1B152

CUB CST SRV (FS)

1B150

CUB (FS)

1B192C

CUB (FS)

1B191D

SEC/WAIT (FS)

1B153

CHF (CD)

1B159

A CHF (CD)

1B158

LD CODE (CD)

1B162

LD CODE (CD)

1B161

SECY (CD)

1B160

WORK (CD)

1B157

A CHF (HIM)

1B143

CHF (HIM)

1B144

SECY (HIM)

1B201

CUB (HIM)

1B195A

CUB (HIM)

1B193D

CUB (HIM)

1B193B

CUB (HIM)

1B195B

CUB (HIM)

1B195D

CUB (HIM)

1B195C

CUB (HIM)

1B192F

CUB (HIM)

1B192D

CUB (HIM)

1B192E

CUB (HIM)

1B193CWAIT/ROI (HIM)

1B200

CHF (WA)

1B137

A CHF (WA)

1B138

SECY (WA)

1B134

OP CTR (WA)

1B130

OFF SPV (WA)

1B132

A CHF (HE)

1C135

BUS CTR (HE)

1C125

T 1B176

CHIEF

1C203

A CHF

1C201

WORKROOM

1C205

SUPV (MCCF)

1B155

IP SUP (HE)

1C134

IP CLRK (HE)

1C124

ADMIS (HE)

1C122

A CHF

1C199

ACCNT CHF

1C214 ACCNT CHF

1C213

ACCNT CHF

1C212

ACCNT CHF

1C211

COMP AUDITOR

1C215

COMP OFFICER

1C216

BDGT

1C217A

TECH

1C217B

AUDITOR

1C193

AUDITOR

1C197

AUDITOR

1C195

RECPT

1C190A

T 1C186

T 1C219

AUDITOR

1C191

BREAK

1C210

SERVICE BAY

1C114

EC

1C223

EC

1B180

SERVICE BAY

1B123

TR

1C114C

NORM ELEC

1C114A

DETAILS (HE)

1C136

WAIT (OC)

1C227

STOR (HE)

1C126

EMER ELEC

1C114B

TR

1B123D

EMER ELEC

1B123A

NORM ELEC

1B123B

SEC/WAIT

1B106

CONF/CLASS (OC)

1B135

T 1B204

CUB (FS)

1B191A

T 1B178

TR

1C228

WAIT

1C190

SERV ELEV LOBB

1B120

PUB ELEV LOBBY

1B100

WORKROOM (HIM)

1B194

CLINICAL SUPER (NSA)

1B102CLINICAL SUPER (NSA)

1B103

T 1C141

T 1C143

WC

1C144

LOUNGE

1C145

RECPT

1C137

PANTRY

1C146

CHAPLAIN

1B105

CHAPLAIN

1B107

CHAPLAIN

1B109

EUCHARIST

1B111

QUIET

1B116

T 1B108

T 1B110

STOR

1B112

HK

1B114

STOR/FILE (FS)

1B190

ISO (HIM)

1B203

PV (HIM)

1B142

SLEEP

1C166

T/S 1C166A

ST

1C181

T/S 1C179A

T/S 1C174A

SLEEP

1C174

SLEEP

1C165

SLEEP

1C175

T/S 1C165A

T/S 1C164A

SLEEP

1C164

SLEEP

1C177

T/S 1C177A

T/S 1C175A

SLEEP

1C179

SLEEP

1C162

T/S 1C162A

WAIT

1C160

CC

1C178 CONF

1C185

RETAIL AREA

1C101

VESTIBULE

1C150

ADMIS (HE)

1C123

STOR

1C221

MONITOR

1C163

POLY

1C161

EQUIP

1C168

T 1C160A

BREAK

1C169

ELEV

BS-1

FUTURE ELEV

BS-2

ELEV

BS-4

ELEV

BS-3

CORR

1B-C01

CORR

1B-C02

CORR

1B-C03

AISLE

1B-C08

CORR

1B-C05

CORR

1B-C06

AISLE

1B-C09

AISLE

1B-C10

AISLE

1B-C11

AISLE

1B-C12

AISLE

1B-C13

AISLE

1C-C01A

AISLE

1C-C01C

AISLE

1C-C01D

AISLE

1C-C03

AISLE

1C-C04

AISLE

1C-C04AAISLE

1C-C04B

AISLE

1C-C05

AISLE

1C-C06

AISLE

1C-C08

AISLE

1C-C08A

STOR

1C133

HK

1C139

VESTIBULE

1B121

CORR

1C101-K

CORR

1B-C02A

HK

1B206

NOUR

1C180

SECURITY

1C114D

UNASSIGNED

1B174G

CUB (HIM)

1B192H

SECURITY

1B123C

CORR

1C-C02

SECY/WAIT (OC)

1C225

RETAIL PREP

1C101A

CORR

1B-C04

AISLE

1B-C04A

AISLE

1C-C00

CORR

1C-C01

CLEAN

1C167

SOILED

1C176

ASR

1B113

CONNECTOR HALL

1B115A

TR

1B179

IT/LVSR

1C190B

CHAPEL

1B115

CLOSET

1B115B

01-AJ-011

D3

01-AJ-011

D1

01-AJ-014

C1

01-AJ-014

C4

01-AJ-015

C1

01-AJ-015

C3

GENERAL SHEET NOTES

NORTH

ROOM ALLOCATION LEGEND

EXISTING TO REMAIN

KEYED NOTES

KEY PLAN

A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY

TO ADD OR REMOVE CABLES WITHOUT RESEALING.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

NEW LOCATION

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AE-011

B & C

OVERALL FIRST FLOOR PLAN - BUILDINGS

B & C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

3/32" = 1'-0"F1 FIRST FLOOR OVERALL PLAN BUILDING H & J

KEY PLAN

Q B

C

D

E

F

G

J

H

K

L M

P

N

S H

O T

G U

N

F

IS

H E

R H

O U

S E

NORTH

Revisions: Date:

DN

UP

DN

UP

DN

DN

UP

RE

TH

TH

RE

RE

TH

TH

RE

RE

RE

RE

RE

RE

RE

CR

CR

OC

OC

CLEAN

2B120

COMM CENTER

2B118

CONSULT

2C126

NOUR

2C108

TR

2C114C

RETHERM

2B101

CONSULT

2C124

HK

2B112

TR

2B123D

STOR/EQUIP

2B103

CLEAN

2B155D

CHUTE

2B105

COMM CENTER

2C104

MED ROOM

2B155B

SOILED

2B155E

SERVICE BAY

2B123

SERVICE BAY

2C114

OFF PHY/CON/NRS

2C120

HOUSE STAFF

2B104

PHARMACIST

2C118

SOC WRK

2C121

HK

2C122

SOC WRK

2C123

PHY/CON/NRS

2C112

STAFF LOUNGE

2B102

STAFF LOCKER

2B126

DIET

2C116

NOUR

2B122

HEAD NURSE

2C113

CARE PROVIDER

2C111

STOR/EQUIP

2C103

HEAD NURSE

2B116

EC

2B153

NORM ELEC

2C114A

EMER ELEC

2C114B

NORM ELEC

2B123B

EMER ELEC

2B123A

SOILED

2C152B

CLEAN

2C106

EC

2C154

PATIENT

2B146

PATIENT NEG

2B143

PATIENT

2B145

PATIENT POS

2B165

PATIENT

2B151

PATIENT

2B152

PATIENT

2B157

PATIENT

2B159

PATIENT

2B161

PATIENT

2B163

PATIENT

2B164

PATIENT

2B144

PATIENT

2B148

PATIENT

2B150

PATIENT

2B154

PATIENT

2B156

PATIENT

2B158

PATIENT

2B160

PATIENT

2B162

PATIENT

2C145

PATIENT

2C151

PATIENT

2C147

PATIENT

2C157

PATIENT

2C159

PATIENT

2C161

PATIENT

2C163

PATIENT

2C155

PATIENT

2C149

PATIENT

2C160

PATIENT POS

2C165

PATIENT

2C141

PATIENT

2C144

PATIENT

2C146

PATIENT

2C148

PATIENT

2C150

PATIENT

2C153

PATIENT

2C156

PATIENT

2C158

PATIENT

2C164PATIENT NEG

2C140

CONF/ REPORT

2B106

SUB-STATION

2B132H

SUB-STATION

2B130A

SUB-STATION

2B130C

SUB-STATION

2B130E

SUB-STATION

2B132D

SUB-STATION

2B132F

SUPPLY

2B130B

SUPPLY

2B132G

SUPPLY

2B132E

SUB-STATION

2C131G

SUB-STATION

2C131C

SUB-STATION

2C131E

SUB-STATION

2C131A

SUB-STATION

2C133A

SUB-STATION

2C133C

RESPITE

2B166

T 2C145A

T 2C162A

T 2C160A

T 2C151A

T 2C155A

T 2C157A

T 2C159A

T 2C161A

T 2C163A

T 2C164A

T 2C149A

T 2C158A

T 2C156A

T 2C153A

T 2C148A

T 2C146A

T 2C144A

ISO T

2C142A

ISO T

2C140A

T 2C143A

T 2C147A

T 2B146A

T 2B140A

T 2B142A

T 2B147A

T 2B145A

T 2B149A

T 2B151A

T 2B152A

T 2B159A

T 2B161A

T 2B163A

ISO T

2B165A

ISO T

2B141A

T 2B164A

T 2B162A

T 2B160A

T 2B158A

T 2B156A

T 2B154A

T 2B150A

T 2B148A

T 2B144A

ISO T

2B143A

MALE

2C101B

ANTE POS

2C165B

X-RAY

2C105

X-RAY ALC

2B115

HC ST

2B126A

TYP T

2B167

ANTE POS

2B165B

PATIENT NEG

2B141

PATIENT

2B142

PATIENT (BAR)

2B140

PATIENT

2B147

PATIENT

2B149

PATIENT NEG

2C142

PATIENT

2C162

ISO T

2C165A

PATIENT

2C143

T 2C141A

PUB ELEV LOBBY

2B100

SERV ELEV LOBBY

2B107

SUPPLY

2C131B

SUPPLY

2C131D

SUPPLY

2C131H

SUPPLY

2C133B

ST

2B125

T 2C167

FEMALE

2C101A

RESPITE

2C166

CARE PROVIDER

2B114

CORR

2B-C01A

CORR

2B-C01

CORR

2B-C04

CORR

2B-C02

CORR

2B-C03

AISLE

2B-C03A

CORR

2C-C03

CORR

2C-C04

CORR

2B-C01B

CORR

2B-C05

ELEV

FUTURE ELEV ELEV

ELEV

SHAFT

SHAFT

SHAFT

SHC06

SHAFT

SHAFT

SUB-STATION

2C133E

SUPPLY

2C133D

SUPPLY

2C131F

CC

2B130F

CC

2C105A

CC

2C165C

CC

2B165C

ON CALL

2B129

ON CALL

2B131

PC1

2C115

CLEAN

2C152C

MED ROOM

2C152E

SECURITY

2C114D

SECURITY

2B123C

PC1

2C109

SUB-STATION

2B132B

CORR

2B-C04B

HC T/S

2B129A

CLST

2B129B

CLST

2B131A

T/S 2B131B

ALCOVE

2C-C03B

ALCOVE

2B-C02A

T 2B157A

SUPPLY

2B130D

SUPPLY

2B132A

CORR

2C-C05

SHAFT

TR

2B155C

TR

2C152G

ST

2C119

01-AJ-025

C1

01-AJ-025

C3

01-AJ-027

C1

01-AJ-027

C4

01-AJ-026

B1

01-AJ-028

B1

TR

2B161A

TR

2C152A AISLE

BP-8

01-AJ-026

D1

01-AJ-028

D1

GENERAL SHEET NOTES

NORTH

ROOM ALLOCATION LEGEND

EXISTING TO REMAIN

KEYED NOTES

KEY PLAN

A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY

TO ADD OR REMOVE CABLES WITHOUT RESEALING.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

NEW LOCATION

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AE-021

B & C

OVERALL SECOND FLOOR PLAN -

BUILDINGS B & C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

3/32" = 1'-0"F1 SECOND FLOOR OVERALL PLAN BUILDING H & J

KEY PLAN

Q B

C

D

E

F

G

J

H

K

L M

P

N

S H

O T

G U

N

F

IS

H E

R H

O U

S E

DN

UP

DN

DN

DN

UP

UP

RE

TH

TH

RE

RE

TH

RE

RE

RE

RE

TH

RE

RE

RE

CR

CR

OC

OC

BLOOD GAS LAB

3C120

COMM CENTER

3C103

CONSULT

3C124

TR

3C114C

CHUTE

3B105

COMM CENTER

3B118

HOUSE STAFF

3B104

HEAD NURSE

3C112

SOC WRK

3C121

SOC WRK

3C123

PHYS/CON/ NRS

3C110

STAFF LOCKER

3B126

DIET

3C116

CARE PROVIDER

3B114

HEAD NURSE

3B116

PHARMACIST

3C118

NOUR

3B122

TR

3B123D

STOR/EQUIP

3B103

SERVICE BAY

3B123

SERVICE BAY

3C114

RETHERM

3B101

NORM ELEC

3B123B

EMER ELEC

3B123A

EMER ELEC

3C114B

NORM ELEC

3C114A

SOILED

3C152B

CLEAN

3B120

FEMALE

3C101A

X-RAY ALC

3C104

PHYS/CON/ NRS

3C122

STOR/EQUIP

3C102

MALE

3C101B

X-RAY ALC

3B115

PATIENT NEG

3B141 PATIENT NEG

3B143

PATIENT

3B145

PATIENT

3B147

ISO T

3B165A

T 3B163A

T 3B161A

T 3B159A

PATIENT

3B149

T 3B157A

T 3B152A

PATIENT

3B151

PATIENT

3B140

PATIENT

3B142

PATIENT

3B144

PATIENT

3B146

PATIENT POS

3B165

T 3B164A

T 3B160A

T 3B158A

T 3B156A

T 3B162A

PATIENT

3B148

PATIENT

3B150

T 3B154A

T 3B151A

PATIENT

3B152

T 3B149A

T 3B147A

T 3B145A

ISO T

3B141A

ISO T

3B143A

PATIENT

3B157

PATIENT

3B159

PATIENT

3B161

PATIENT

3B163

PATIENT

3B164

PATIENT

3B154

PATIENT

3B156

PATIENT

3B158

PATIENT

3B160

PATIENT

3B162

T 3B150A

T 3B148A

T 3B146A

T 3B144A

T 3B142A

T 3B140A

EC

3C154

SUB-STATION

3B130A SUPPLY

3B130B

SUB-STATION

3B130C

SUPPLY

3B130D

SUB-STATION

3B130E

SUB-STATION

3B132D

SUB-STATION

3B132HSUPPLY

3B132E

RESPITE

3B166

SUB-STATION

3B132F

SERV ELEV LOBBY

3B107

PUB ELEV LOBBY

3B100

HK

3B112

NOUR

3C108

CLEAN

3C106

SOILED

3B155E

EC

3B153

SUB-STATION

3C131A

SUB-STATION

3C131C

SUB-STATION

3C131E

SUB-STATION

3C133A

SUB-STATION

3C133C SUB-STATION

3C133E

T 3C163A

ISO T

3C140A

ISO T

3C142A

T 3C144A

T 3C146A

PATIENT

3C146

T 3C148A

PATIENT

3C148

PATIENT

3C150

T 3C150A

PATIENT

3C153

T 3C153A

T 3C156A

PATIENT

3C156

PATIENT

3C158

T 3C158A

T 3C162A

PATIENT

3C160

T 3C160A

T 3C141A

ISO T

3C165A

PATIENT

3C162

PATIENT

3C164

PATIENT

3C163

PATIENT

3C161PATIENT

3C159

PATIENT

3C157

SUPPLY

3C131B

SUPPLY

3C131D

SUPPLY

3C133B

RESPITE

3C166

T 3C164A

T 3C159A

T 3C161A

T 3C157A

T 3C155A

T 3C151A

T 3C149A

T 3C147A

T 3C145A

T 3C143A

PATIENT NEG

3C140

PATIENT NEG

3C142

PATIENT

3C155

PATIENT

3C151

PATIENT

3C149

PATIENT

3C147

PATIENT

3C145

PATIENT

3C143

PATIENT

3C141

PATIENT POS

3C165

ANTE POS

3C165B

STAFF LOUNGE

3B102

ST

3B124

T 3B167

T 3C167

ANTE POS

3B165B

HC ST

3B126A

AISLE

3B-C01A

CORR

3B-C01

CORR

3B-C01B

CORR

3B-C02

CORR

3B-C05

CORR

3B-C03

CORR

3C-C03

CORR

3C-C04A

CORR

3C-C02

ELEV

BS-1

FUTURE ELEV

BS-2

ELEV

ELEV

STAIR

STB-1

SHAFT

SHB01

SHAFT

SHAFT

SHAFT

SHAFT

SUPPLY

3B132A

SUPPLY

3B132G

SUPPLY

3C133D

TR

3B161A

CC

3B130H

TR

3C152A

CC

3C109

HK

3C125

CC

3C165C

CC

3B165C

ST

3B227

CARE PROVIDER

3C230

CLEAN

3B155D

MED ROOM

3B155B AISLE

3B-C03A

CLEAN

3C152C

MED ROOM

3C152E

AISLE

3C-C02A

STAIR

STC-4

STAIR

STC-3

SECURITY

3C114D

SECURITY

3B123C

UNASSIGNED

3C117

PATIENT

3C144

CORR

3B-C04B

SUB-STATION

3B132B

SUB-STATION

3C131G

ALCOVE

3C-C03B

ALCOVE

3B-C02A

OFF PCI

3B131

HC ON CALL

3B129

HC T/S

3B129A

PHYS/CON/NRS

3B130

CLST

3B129B

CONSULT

3C126

SUPPLY

3C131H

SHAFT

CORR

3C-C06

WAITING

3A100A

TEL CLST

3B155C

TEL CLST

3C152D

CONF/ REPORT

1C190C

01-AJ-035

C1

01-AJ-035

C4

01-AJ-037

C1

01-AJ-037

C4

01-AJ-036

B1

01-AJ-038

B1

01-AJ-038

D1

01-AJ-036

D1

GENERAL SHEET NOTES

NORTH

ROOM ALLOCATION LEGEND

EXISTING TO REMAIN

KEYED NOTES

KEY PLAN

A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY

TO ADD OR REMOVE CABLES WITHOUT RESEALING.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

NEW LOCATION

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AE-031

B & C

OVERALL THIRD FLOOR PLAN - BUILDINGS

B & C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

3/32" = 1'-0"F1 THIRD FLOOR OVERALL PLAN BUILDING H & J

KEY PLAN

Q B

C

D

E

F

G

J

H

K

L M

P

N

S H

O T

G U

N

F

IS

H E

R H

O U

S E

UPDN

DN

DN

UP

TH

RE

RE

TH

TH

RE

RE

RE

RE

RE

RE

RE

CR

OC

SERVICE BAY

4B123

SERVICE BAY

4C114

CONSULT

4B105

NOUR

4B122

TR

4B123D

RETHERM

4B121

CHUTE

4B104

COMM CENTER

4B118

STAFF LOUNGE

4B109

CONF/ REPORT

4B106

HOUSE STAFF

4B107

RESIDENT CONF

4B108

PCI

4B102

SOC WRK

4B110

CLEAN

4B155D

DIET

4B125

HEAD NURSE

4B114

CARE PROVIDER

4B116

STOR/EQUIP

4B103

HC ST

4B126A

STAFF LOCKER

4B126

EC

4B153

TR

4C114C

NORM ELEC

4B123B

EMER ELEC

4B123A

EMER ELEC

4C114B

NORM ELEC

4C114A

PATIENT NEG

4B143

MED ROOM

4B155B

SOILED

4B155E

CLEAN

4B120

ISO T

4B141A

ISO T

4B143A

PATIENT

4B163

T 4B145A

PATIENT

4B161

T 4B147A

PATIENT

4B159

T 4B149A

PATIENT

4B157

T 4B151A

PATIENT

4B152

T 4B140A

PATIENT

4B164

T 4B142A

PATIENT

4B162

T 4B144A

PATIENT

4B160

T 4B146A

T 4B148A

PATIENT

4B158

T 4B150A

PATIENT

4B156

T 4B154A

PATIENT

4B154

T 4B156A

PATIENT

4B151

T 4B158A

PATIENT

4B149

T 4B160A

PATIENT

4B147

T 4B162A

PATIENT

4B145

T 4B164A

PATIENT

4B142

PATIENT

4B140

T 4B163A

PATIENT

4B150

T 4B161A

PATIENT

4B148

T 4B159A

PATIENT

4B146

T 4B157A

PATIENT

4B144

T 4B152A

SUB-STATION

4B130A

SUB-STATION

4B130C

SUB-STATION

4B130E

SUB-STATION

4B132H

SUB-STATION

4B132D

SUB-STATION

4B132F

RESPITE

4B166

ANTE POS

4B165B

PATIENT NEG

4B141

PATIENT POS

4B165

PUB ELEV LOBBY

4B100

SERV ELEV LOBBY

4B111

X-RAY ALC

4B115

SUPPLY

4B130D

SUPPLY

4B130B

SUPPLY

4B132E

ISO T

4C134A

BED STATION ISO

4C134

BED STATION

4C128

BED STATION

4C130

BED STATION

4C132

T 4C135

CLEAN

4C137

SOILED

4C141

EQ CLEAN STOR

4C136

MED

4C127

DIALYSATE STOR

4C120

CH NURSE

4C126

STOR STERILE

4C123

WATER TREAT

4C110

EQUIP SERVICE

4C111

WC

4C113

CUB

4C122B

CC

4C118

LOCKER

4C112

ST

4C121

T 4B167

T/S 4C106A

T/S 4C105A

T/S 4C104A

ON CALL

4C107

ON CALL

4C103

ON CALL

4C106

ON CALL

4C105

ST

4B127A

ISO T

4B165A

NOUR

4C139

OFF PHYSICIAN

4C124

CUB

4C122A

T/S 4C107A

HC T/S

4C103A

T/S 4C102A

ON CALL

4C102

ON CALL

4C104

EQUIP SOIL/PREP

4C138

NURSE STA

4C125

AISLE

4B-C01A

CORR

4B-C01

CORR

4B-C02 CORR

4B-C03

CORR

4B-C04

CORR

4B-C04A

CORR

4C-C01

CORR

4C-C02

CORR

4C-C03

CORR

4C-C04

CORR

4C-C05

CORR

4C-C06

AISLE

4C-C06A

ELEV

BS-1

FUTURE ELEV

BS-2

ELEV

BS-4

ELEV

BS-3

STAIR

STB-1

SHAFT

SHB01

SHAFT

SHB03

SHAFT

SHC06

SHAFT

SHC05B

SHAFT

SHC05A

SUPPLY

4B132A

SUPPLY

4B132G

SCALE

4C119

HK

4B112

CC

4B165C

P/C/N OFFICE

4B113

AISLE

4B-C03A

TR

4B161A

STAIR

STC-4

SECURITY

4B123C

SECURITY

4C114D

SUB-STATION

4B132B

CORR

4B-C01B

CORR

4B-C04B

CLST

4C107B

CLST

4C105B

CLST

4C103B

CLST

4C102B

CLST

4C104B

CLST

4C106B

CORR

4B-C05

ALCOVE

4B-C02A

ALCOVE

4C136A

ALCOVE

4C128A

MALE

4C101B

FEMALE

4C101A

SHAFT

SHC05C

TR

4B155C

01-AJ-044

C1

01-AJ-044

C3

01-AJ-045

B1

01-AJ-045

D1

GENERAL SHEET NOTES

NORTH

ROOM ALLOCATION LEGEND

EXISTING TO REMAIN

KEYED NOTES

KEY PLAN

A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY

TO ADD OR REMOVE CABLES WITHOUT RESEALING.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

NEW LOCATION

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AE-041

B & C

OVERALL FOURTH FLOOR PLAN -

BUILDINGS B & C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

3/32" = 1'-0"F1 FOURTH FLOOR OVERALL PLAN BUILDING H & J

KEY PLAN

Q B

C

D

E

F

G

J

H

K

L M

P

N

S H

O T

G U

N

F

IS

H E

R H

O U

S E

C L

KEY PLAN

NORTH

GENERAL NOTES ARCHITECTURAL

A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY

TO ADD OR REMOVE CABLES WITHOUT RESEALING.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE

EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.

GENERAL NOTES REFLECTED CEILING

A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.

B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.

GENERAL SHEET NOTES

GYP. BD. CEILING SYSTEM

2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.

DOWN LIGHT FIXTURE

LEGEND

KEYED NOTES

1'X4' LIGHT FIXTURE

8' X 7" LIGHT FIXTURE

2'X4' LIGHT FIXTURE

2'X2' SUPPLY

2'X2' RETURN

01-AJ-011

D5

CHF (OC)

1C220

A CHF (OC)

1C222

SECY (OC)

1B208

ITAC (OC)

1B141

CS (OC)

1B139

OFF CHF (FS)

1B151

BA (OC)

1C224

ADM (OC)

1B140

MA ASST (OC)

1C226

MEDIA (FS)

1B154

OFF A CHF (FS)

1B152

CUB CST SRV (FS)

1B150

SEC/WAIT (FS)

1B153

CHF (CD)

1B159

A CHF (CD)

1B158

LD CODE (CD)

1B162

LD CODE (CD)

1B161

SECY (CD)

1B160

WORK (CD)

1B157

A CHF (HIM)

1B143

CHF (HIM)

1B144

SECY (HIM)

1B201

CHF (WA)

1B137

A CHF (WA)

1B138

SECY (WA)

1B134

OP CTR (WA)

1B130

OFF SPV (WA)

1B132

A CHF (HE)

1C135

BUS CTR (HE)

1C125

T 1B176

CHIEF

1C203

A CHF

1C201

WORKROOM

1C205

SUPV (MCCF)

1B155

IP SUP (HE)

1C134

IP CLRK (HE)

1C124

ADMIS (HE)

1C122

A CHF

1C199

ACCNT CHF

1C214

ACCNT CHF

1C213 ACCNT CHF

1C212

ACCNT CHF

1C211

COMP AUDITOR

1C215

COMP OFFICER

1C216

BDGT

1C217A

TECH

1C217B

AUDITOR

1C193

AUDITOR

1C197

AUDITOR

1C195

RECPT

1C190A

T 1C186

T 1C219

AUDITOR

1C191

BREAK

1C210

SERVICE BAY

1C114

EC

1C223

EC

1B180

SERVICE BAY

1B123

TR

1C114C

NORM ELEC

1C114A

DETAILS (HE)

1C136

WAIT (OC)

1C227

STOR (HE)

1C126

EMER ELEC

1C114B

TR

1B123D

EMER ELEC

1B123A

NORM ELEC

1B123B

SEC/WAIT

1B106

CONF/CLASS (OC)

1B135

T 1B204

T 1B178

TR

1C228

WAIT

1C190

SERV ELEV LOBB

1B120

PUB ELEV LOBBY

1B100

WORKROOM (HIM)

1B194

CLINICAL SUPER (NSA)

1B102CLINICAL SUPER (NSA)

1B103

T 1C141

T 1C143

WC

1C144

LOUNGE

1C145

RECPT

1C137

PANTRY

1C146

CHAPLAIN

1B105

CHAPLAIN

1B107

CHAPLAIN

1B109

EUCHARIST

1B111

QUIET

1B116

T 1B108

T 1B110

STOR

1B112

HK

1B114

STOR/FILE (FS)

1B190

ISO (HIM)

1B203

PV (HIM)

1B142

SLEEP

1C166

T/S 1C166A

ST

1C181

T/S 1C179A

T/S

1C174A SLEEP

1C174

SLEEP

1C165

SLEEP

1C175

T/S 1C165A

T/S 1C164A

SLEEP

1C164

SLEEP

1C177

T/S 1C177A

T/S 1C175A

SLEEP

1C179

SLEEP

1C162

T/S 1C162A

WAIT

1C160 CC

1C178 CONF

1C185

RETAIL AREA

1C101

VESTIBULE

1C150

ADMIS (HE)

1C123

STOR

1C221

MONITOR

1C163

POLY

1C161

EQUIP

1C168

T 1C160A

BREAK

1C169

ELEV

BS-1

FUTURE ELEV

BS-2

ELEV

BS-4

ELEV

BS-3

STAIR

STB-1

CORR

1B-C01

CORR

1B-C02

CORR

1B-C03

CORR

1B-C05

AISLE

1B-C09

AISLE

1B-C10

AISLE

1B-C11

AISLE

1B-C13

AISLE

1C-C01D

AISLE

1C-C03

AISLE

1C-C04

AISLE

1C-C04A

AISLE

1C-C04B

AISLE

1C-C05

AISLE

1C-C06

AISLE

1C-C08

AISLE

1C-C08A

STOR

1C133

HK

1C139

VESTIBULE

1B121

CORR

1C101-K

CORR

1B-C02A

HK

1B206

NOUR

1C180

AISLE

1C-C07A

SECURITY

1C114D

UNASSIGNED

1B174G

SECURITY

1B123C

CORR

1C-C02

SECY/WAIT (OC)

1C225

RETAIL PREP

1C101A

CORR

1B-C04

AISLE

1B-C04A

AISLE

1C-C00

CORR

1C-C01

CLEAN

1C167

SOILED

1C176

ASR

1B113 CONNECTOR HALL

1B115A

TR

1B179

IT/LVSR

1C190B

CHAPEL

1B115

CLOSET

1B115B

01-AJ-011

D7

01-AJ-014

F1

01-AJ-014

F4

01-AJ-015

C6

01-AJ-015

C8

7"

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AC-011

B & C

LEVEL 1 REFLECTED CEILING PLAN

BUILDINGS B & C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

3/32" = 1'-0"F1

FIRST FLOOR REFLECTIVE CEILING PLAN

KEY PLAN

Q B

C

D

E

F

G

J

H

K

L M

P

N

S H

O T

G U

N

F

IS

H E

R H

O U

S E

NN NN NNNNNNN

N

N

N

N

N N

N

N

N

N

NN NN NNNNNNNNN

N N N N NN N N N N N N N

N N N N N N N N

N

KEY PLAN

NORTH

GENERAL NOTES ARCHITECTURAL

A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY

TO ADD OR REMOVE CABLES WITHOUT RESEALING.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE

EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.

GENERAL NOTES REFLECTED CEILING

A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.

B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.

GENERAL SHEET NOTES

GYP. BD. CEILING SYSTEM

2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.

DOWN LIGHT FIXTURE

LEGEND

KEYED NOTES

1'X4' LIGHT FIXTURE

8' X 7" LIGHT FIXTURE

2'X4' LIGHT FIXTURE

2'X2' SUPPLY

2'X2' RETURN

CLEAN

2B120

COMM CENTER

2B118

CONSULT

2C126

NOUR

2C108

TR

2C114C

RETHERM

2B101

CONSULT

2C124

HK

2B112

TR

2B123D

STOR/EQUIP

2B103

CLEAN

2B155D

CHUTE

2B105

COMM CENTER

2C104

MED ROOM

2B155B

SOILED

2B155E

SERVICE BAY

2B123

SERVICE BAY

2C114

OFF PHY/CON/NRS

2C120

HOUSE STAFF

2B104

PHARMACIST

2C118

ST

2C119

SOC WRK

2C121

HK

2C122

SOC WRK

2C123

PHY/CON/NRS

2C112

STAFF LOUNGE

2B102

STAFF LOCKER

2B126

DIET

2C116

NOUR

2B122

HEAD NURSE

2C113

CARE PROVIDER

2C111

STOR/EQUIP

2C103

HEAD NURSE

2B116

EC

2B153

NORM ELEC

2C114A

EMER ELEC

2C114B

NORM ELEC

2B123B

EMER ELEC

2B123A

SOILED

2C152B

CLEAN

2C106

EC

2C154

PATIENT

2B146

PATIENT NEG

2B143

PATIENT

2B145

PATIENT POS

2B165

PATIENT

2B151

PATIENT

2B152

PATIENT

2B157

PATIENT

2B159

PATIENT

2B161

PATIENT

2B163

PATIENT

2B164

PATIENT

2B144

PATIENT

2B148

PATIENT

2B150

PATIENT

2B154

PATIENT

2B156

PATIENT

2B158

PATIENT

2B160 PATIENT

2B162

PATIENT

2C145

PATIENT

2C151

PATIENT

2C147

PATIENT

2C157

PATIENT

2C159

PATIENT

2C161

PATIENT

2C163

PATIENT

2C155

PATIENT

2C149

PATIENT

2C160

PATIENT POS

2C165

PATIENT

2C141

PATIENT

2C144

PATIENT

2C146

PATIENT

2C148

PATIENT

2C150

PATIENT

2C153

PATIENT

2C156

PATIENT

2C158

PATIENT

2C164

PATIENT NEG

2C140

CONF/ REPORT

2B106

SUB-STATION

2B132H

SUB-STATION

2B130A

SUB-STATION

2B130C

SUB-STATION

2B130E

SUB-STATION

2B132D SUB-STATION

2B132F

SUPPLY

2B130B

SUPPLY

2B132G

SUPPLY

2B132E

SUB-STATION

2C131G

SUB-STATION

2C131C

SUB-STATION

2C131E

SUB-STATION

2C131A SUB-STATION

2C133A

SUB-STATION

2C133C

RESPITE

2B166

T 2C145A

T 2C162A

T 2C160A

T 2C151A

T 2C155A

T 2C157A

T 2C159A

T 2C161A

T 2C163A

T 2C164A

T 2C149A

T 2C158A

T 2C156A

T 2C153A

T 2C148A

T 2C146A

T 2C144A

ISO T

2C142A

ISO T

2C140A

T 2C143A

T 2C147A

T 2B146A

T 2B140A

T 2B142A

T 2B147A

T 2B145A

T 2B149A

T 2B151A

T 2B152A

T 2B159A T

2B161A

T 2B163A

ISO T

2B165A

ISO T

2B141A

T 2B164A

T 2B162A

T 2B160A

T 2B158A

T

2B156AT

2B154A T

2B150A

T 2B148A

T 2B144A

ISO T

2B143A

MALE

2C101B

ANTE POS

2C165B

X-RAY

2C105

X-RAY ALC

2B115

HC ST

2B126A

TYP T

2B167

ANTE POS

2B165B

PATIENT NEG

2B141

PATIENT

2B142

PATIENT (BAR)

2B140

PATIENT

2B147

PATIENT

2B149

PATIENT NEG

2C142

PATIENT

2C162

ISO T

2C165A

PATIENT

2C143

T 2C141A

PUB ELEV LOBBY

2B100

SERV ELEV LOBBY

2B107

SUPPLY

2C131B SUPPLY

2C131D

SUPPLY

2C131H

SUPPLY

2C133B

ST

2B125

T 2C167

FEMALE

2C101A

RESPITE

2C166

CARE PROVIDER

2B114

CORR

2B-C01A

CORR

2B-C01

CORR

2B-C04

CORR

2B-C02

CORR

2B-C03

AISLE

2B-C03A

CORR

2C-C03

CORR

2C-C04

CORR

2B-C01B

CORR

2B-C05

ELEV

BS-1

FUTURE ELEV

BS-2

ELEV

BS-4

ELEV

BS-3

STAIR

STB-1

SHAFT

SHB01

SHAFT

SHB03

SHAFT

SHC06

SHAFT

SHC05B

SHAFT

SHC05A

SUB-STATION

2C133E

SUPPLY

2C133D

SUPPLY

2B132C

SUPPLY

2C131F

CC

2B130F

CC

2C105A

CC

2C165C

CC

2B165C

ON CALL

2B129

ON CALL

2B131

PC1

2C115

CLEAN

2C152C

MED ROOM

2C152E

STAIR

STC-4

STAIR

STC-3

SECURITY

2C114D

SECURITY

2B123C

PC1

2C109

SUB-STATION

2B132B

CORR

2B-C04B

HC T/S

2B129ACLST

2B129B

CLST

2B131A T/S

2B131B

ALCOVE

2C-C03B

ALCOVE

2B-C02A

T 2B157A

SUPPLY

2B130D

SUPPLY

2B132A

CORR

2C-C05

SHAFT

SHC05C

WAITING

2A100A

TR

2B155C

TR

2C152G

01-AJ-025

F1

01-AJ-025

F4

01-AJ-027

F1

01-AJ-027

F4

TR

2C152A

AISLE

BP-8

TR

2B161A

01-AJ-026

F1

01-AJ-028

F1

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AC-021

B & C

LEVEL 2 REFLECTED CEILING PLAN

BUILDINGS B & C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

0' 4' 8' 16'

KEY PLAN

Q B

C

D

E

F

G

J

H

K

L M

P

N

S H

O T

G U

N

F

IS

H E

R H

O U

S E

3/32" = 1'-0"F1

SECOND FLOOR REFLECTIVE CEILING PLAN BUILDINGS B & C

N N N N N N

N N N N N N

N N

N N N N N N N

N N N N N

NN NN N

NN NN NNN

NNNNNN

NNNNNN

KEY PLAN

NORTH

GENERAL NOTES ARCHITECTURAL

A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY

TO ADD OR REMOVE CABLES WITHOUT RESEALING.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE

EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.

GENERAL NOTES REFLECTED CEILING

A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.

B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.

GENERAL SHEET NOTES

GYP. BD. CEILING SYSTEM

2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.

DOWN LIGHT FIXTURE

LEGEND

KEYED NOTES

1'X4' LIGHT FIXTURE

8' X 7" LIGHT FIXTURE

2'X4' LIGHT FIXTURE

2'X2' SUPPLY

2'X2' RETURN

BLOOD GAS LAB

3C120

COMM CENTER

3C103

CONSULT

3C124

TR

3C114C

CHUTE

3B105

COMM CENTER

3B118

HOUSE STAFF

3B104

HEAD NURSE

3C112

SOC WRK

3C121

SOC WRK

3C123

PHYS/CON/ NRS

3C110

STAFF LOCKER

3B126

DIET

3C116

CARE PROVIDER

3B114

HEAD NURSE

3B116

PHARMACIST

3C118

NOUR

3B122

TR

3B123D

STOR/EQUIP

3B103

SERVICE BAY

3B123

SERVICE BAY

3C114

RETHERM

3B101

NORM ELEC

3B123B

EMER ELEC

3B123A

EMER ELEC

3C114B

NORM ELEC

3C114A

SOILED

3C152B

CLEAN

3B120

FEMALE

3C101A

X-RAY ALC

3C104

PHYS/CON/ NRS

3C122

STOR/EQUIP

3C102

MALE

3C101B

X-RAY ALC

3B115

PATIENT NEG

3B141

PATIENT NEG

3B143

PATIENT

3B145

PATIENT

3B147

ISO T

3B165A

T 3B163A

T 3B161A

T 3B159A

PATIENT

3B149

T 3B157A

T 3B152A

PATIENT

3B151

PATIENT

3B140

PATIENT

3B142

PATIENT

3B144

PATIENT

3B146

PATIENT POS

3B165

T 3B164A

T 3B160A

T 3B158A

T 3B156A

T 3B162A

PATIENT

3B148

PATIENT

3B150

T 3B154A

T 3B151A

PATIENT

3B152

T 3B149A

T 3B147A

T 3B145A

ISO T

3B141A

ISO T

3B143A

PATIENT

3B157

PATIENT

3B159

PATIENT

3B161

PATIENT

3B163

PATIENT

3B164

PATIENT

3B154

PATIENT

3B156

PATIENT

3B158

PATIENT

3B160

PATIENT

3B162

T 3B150A

T 3B148A

T 3B146A

T 3B144A

T 3B142A

T 3B140A

EC

3C154

SUB-STATION

3B130A SUPPLY

3B130B

SUB-STATION

3B130C

SUPPLY

3B130D

SUB-STATION

3B130E

SUB-STATION

3B132DSUPPLY

3B132C

SUB-STATION

3B132HSUPPLY

3B132E

RESPITE

3B166

SUB-STATION

3B132F

SERV ELEV LOBBY

3B107

PUB ELEV LOBBY

3B100

HK

3B112

NOUR

3C108

CLEAN

3C106

SOILED

3B155E

EC

3B153

SUB-STATION

3C131A

SUB-STATION

3C131C

SUB-STATION

3C131E

SUB-STATION

3C133A

SUB-STATION

3C133C SUB-STATION

3C133E

T 3C163A

ISO T

3C140A

ISO T

3C142A

T 3C144A

T 3C146A

PATIENT

3C146

T 3C148A

PATIENT

3C148

PATIENT

3C150

T 3C150A

PATIENT

3C153

T 3C153A

T 3C156A

PATIENT

3C156

PATIENT

3C158

T 3C158A

T 3C162A

PATIENT

3C160

T 3C160A

T

3C141A ISO T

3C165A

PATIENT

3C162

PATIENT

3C164

PATIENT

3C163

PATIENT

3C161

PATIENT

3C159

PATIENT

3C157

SUPPLY

3C131B

SUPPLY

3C131D

SUPPLY

3C133B

RESPITE

3C166

T 3C164A

T 3C159A

T 3C161A

T 3C157A

T 3C155A

T 3C151A

T 3C149A

T 3C147A

T 3C145A

T 3C143A

PATIENT NEG

3C140

PATIENT NEG

3C142

PATIENT

3C155

PATIENT

3C151

PATIENT

3C149

PATIENT

3C147

PATIENT

3C145

PATIENT

3C143

PATIENT

3C141

PATIENT POS

3C165

ANTE POS

3C165B

STAFF LOUNGE

3B102

ST

3B124

T 3B167

T 3C167

ANTE POS

3B165B

HC ST

3B126A

AISLE

3B-C01A

CORR

3B-C01

CORR

3B-C01B

CORR

3B-C02

CORR

3B-C05

CORR

3B-C03

CORR

3C-C03

CORR

3C-C04A

CORR

3C-C02

ELEV

BS-1

FUTURE ELEV

BS-2

ELEV

BS-4

ELEV

BS-3

STAIR

STB-1

SHAFT

SHB01

SHAFT

SHB03

SHAFT

SHC06

SHAFT

SHC05B

SHAFT

SHC05A

SUPPLY

3B132A

SUPPLY

3B132G

SUPPLY

3C133D

TR

3B161A

CC

3B130H

TR

3C152A

CC

3C109

HK

3C125

CC

3C165C

CC

3B165C

ST

3B227

CARE PROVIDER

3C230

CLEAN

3B155D

MED ROOM

3B155B

AISLE

3B-C03A

CLEAN

3C152C

MED ROOM

3C152E

AISLE

3C-C02A

STAIR

STC-4

STAIR

STC-3

SECURITY

3C114D

SECURITY

3B123C

UNASSIGNED

3C117

PATIENT

3C144

CORR

3B-C04B

SUB-STATION

3B132B

SUPPLY

3C131F

SUB-STATION

3C131G

ALCOVE

3C-C03B

ALCOVE

3B-C02A

OFF PCI

3B131

HC ON CALL

3B129

HC T/S

3B129A

PHYS/CON/NRS

3B130

CLST

3B129B

CONSULT

3C126

SUPPLY

3C131H

SHAFT

SHC05C

CORR

3C-C06

WAITING

3A100A

TEL CLST

3B155C

TEL CLST

3C152D

CONF/ REPORT

1C190C

01-AJ-035

F1

01-AJ-035

F4

01-AJ-037

F1

01-AJ-037

F4

01-AJ-038

F1

01-AJ-036

F1

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AC-031

B & C

LEVEL 3 REFLECTED CEILING PLAN

BUILDINGS B & C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

KEY PLAN

Q B

C

D

E

F

G

J

H

K

L M

P

N

S H

O T

G U

N

F

IS

H E

R H

O U

S E

3/32" = 1'-0"F1

THIRD FLOOR REFLECTIVE CEILING PLAN BUILDINGS B & C

AP

APAPAP

AP

NNNNNNN

NN NN N

NN NN NNN

NNNNNN

KEY PLAN

NORTH

GENERAL NOTES ARCHITECTURAL

A. THE C.O.R. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR, TO ALLOW CABLES TO PENETRATE WALLS WITHOUT LIMITING ABILITY

TO ADD OR REMOVE CABLES WITHOUT RESEALING.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. REFER TO SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

G. PORTION OF WALL TO REMAIN UNTIL LOW VOLTAGE/TELECOM PROVIDER CAN RELOCATE

EXISTING EQUIPMENT. CONTRACTOR TO CORDINATE WITH VA COR AND PROVIDER.

GENERAL NOTES REFLECTED CEILING

A. RESTORE EFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.

B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.

GENERAL SHEET NOTES

GYP. BD. CEILING SYSTEM

2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.

DOWN LIGHT FIXTURE

LEGEND

KEYED NOTES

1'X4' LIGHT FIXTURE

8' X 7" LIGHT FIXTURE

2'X4' LIGHT FIXTURE

2'X2' SUPPLY

2'X2' RETURN

SERVICE BAY

4B123

SERVICE BAY

4C114

CONSULT

4B105

NOUR

4B122

TR

4B123D

RETHERM

4B121

CHUTE

4B104

COMM CENTER

4B118

STAFF LOUNGE

4B109

CONF/ REPORT

4B106

HOUSE STAFF

4B107

RESIDENT CONF

4B108

PCI

4B102

SOC WRK

4B110

CLEAN

4B155D

DIET

4B125

HEAD NURSE

4B114

CARE PROVIDER

4B116

WAITING

4A100A

STOR/EQUIP

4B103

HC ST

4B126A

STAFF LOCKER

4B126

EC

4B153

TR

4C114C

NORM ELEC

4B123B

EMER ELEC

4B123A

EMER ELEC

4C114B

NORM ELEC

4C114A

PATIENT NEG

4B143 MED ROOM

4B155B

SOILED

4B155E

CLEAN

4B120

ISO T

4B141A

ISO T

4B143A

PATIENT

4B163

T 4B145A

PATIENT

4B161

T 4B147A

PATIENT

4B159

T 4B149A

PATIENT

4B157

T 4B151A

PATIENT

4B152

T 4B140A

PATIENT

4B164

T 4B142A

PATIENT

4B162

T 4B144A

PATIENT

4B160

T 4B146A

T 4B148A

PATIENT

4B158

T 4B150A

PATIENT

4B156

T 4B154A

PATIENT

4B154

T 4B156A

PATIENT

4B151

T 4B158A

PATIENT

4B149

T 4B160A

PATIENT

4B147

T 4B162A

PATIENT

4B145

T 4B164A

PATIENT

4B142

PATIENT

4B140

T 4B163A

PATIENT

4B150

T 4B161A

PATIENT

4B148

T 4B159A

PATIENT

4B146

T 4B157A

PATIENT

4B144

T 4B152A

SUB-STATION

4B130A

SUB-STATION

4B130C

SUB-STATION

4B130E

SUB-STATION

4B132H

SUB-STATION

4B132D

SUB-STATION

4B132F

RESPITE

4B166

ANTE POS

4B165B

PATIENT NEG

4B141

PATIENT POS

4B165

PUB ELEV LOBBY

4B100

SERV ELEV LOBBY

4B111

X-RAY ALC

4B115

SUPPLY

4B130D

SUPPLY

4B130B

SUPPLY

4B132E

ISO T

4C134A

BED STATION ISO

4C134

BED STATION

4C128

BED STATION

4C130

BED STATION

4C132

T 4C135

CLEAN

4C137

SOILED

4C141

EQ CLEAN STOR

4C136

MED

4C127

DIALYSATE STOR

4C120

CH NURSE

4C126

STOR STERILE

4C123

WATER TREAT

4C110

EQUIP SERVICE

4C111

WC

4C113

CUB

4C122B

CC

4C118

LOCKER

4C112 ST

4C121

T 4B167

T/S 4C106A

T/S 4C105A

T/S 4C104A

ON CALL

4C107

ON CALL

4C103

ON CALL

4C106

ON CALL

4C105

ST

4B127A

ISO T

4B165A

NOUR

4C139

OFF PHYSICIAN

4C124

CUB

4C122A

T/S 4C107A

HC T/S

4C103A

T/S 4C102A

ON CALL

4C102

ON CALL

4C104

EQUIP SOIL/PREP

4C138

NURSE STA

4C125

AISLE

4B-C01A

CORR

4B-C01

CORR

4B-C02

CORR

4B-C03

CORR

4B-C04

CORR

4B-C04A

CORR

4C-C01

CORR

4C-C02 CORR

4C-C03

CORR

4C-C04

CORR

4C-C05

CORR

4C-C06

AISLE

4C-C06A

ELEV

BS-1

FUTURE ELEV

BS-2

ELEV

BS-4

ELEV

BS-3

STAIR

STB-1

SHAFT

SHB01

SHAFT

SHB03

SHAFT

SHC06

SHAFT

SHC05B

SHAFT

SHC05A

SUPPLY

4B132A

SUPPLY

4B132G

SCALE

4C119

HK

4B112

CC

4B165C

P/C/N OFFICE

4B113

AISLE

4B-C03A

TR

4B161A

STAIR

STC-4

SECURITY

4B123C

SECURITY

4C114D

SUB-STATION

4B132B

CORR

4B-C01B

CORR

4B-C04B

CLST

4C107B

CLST

4C105B

CLST

4C103B

CLST

4C102B

CLST

4C104B

CLST

4C106B

CORR

4B-C05

ALCOVE

4B-C02A

ALCOVE

4C136A

ALCOVE

4C128A

MALE

4C101B

FEMALE

4C101A

SHAFT

SHC05C

TR

4B155C

01-AJ-044

F1

01-AJ-044

F4

01-AJ-045

F1

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AC-041

B & C

LEVEL 4 REFLECTED CEILING PLAN

BUILDINGS B & C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

KEY PLAN

Q B

C

D

E

F

G

J

H

K

L M

P

N

S H

O T

G U

N

F

IS

H E

R H

O U

S E

3/32" = 1'-0"F1

FOURTH FLOOR REFLECTIVE CEILING PLAN BUILDINGS B & C

TH

F

F

FD

TR

1C114C

1A104B

128R

128R

128R

T 1C143

SECURITY

1C114D

STOR

1C133

TR

1C114C

1A104B

T 1C143

SECURITY

1C114D

STOR

1C133

TR

1C114C

1A104B

94D

101D

STOR

1C133

SECURITY

1C114D

T 1C143

TR

1C114C

1A104B

130R

SECURITY

1C114D

STOR

1C133

T 1C143

130R

GENERAL NOTE DEMOLITION

A. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION. BRING SIGNIFICANT

DISCREPANCIES TO THE ATTENTION OF THE COR. FOR REVIEW.

B. COORDINATE DEMOLITION TIMING WITH THE COR. PRIOR TO START.

C. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION, INCLUDING

MECHANICAL & FIRE SUPPRESSION SYSTEMS.

D. UPON COMPLETION OF DEMOLITION, PREPARE SUBSTRATE AS REQUIRED TO RECEIVE NEW FINISH

PER ARCHITECTURAL DRAWINGS. REPAIR ANY DAMAGE INCURRED DURING OR PRIOR TO THE

START OF WORK TO MATCH EXISTING CONDITION INCLUDING FIREPROOF MATERIALS.

E. SALVAGE AND RETURN TO C.O.R. EXISTING LIGHT FIXTURES TO BE REMOVED PER DRAWINGS.

F. EXISTING WALL MOUNTED DEVICES TO REMAIN UNLESS NOTED OTHERWISE, INCLUDED BUT NOT

LIMITED TO THERMOSTATS, LIGHT SWITCHES, OUTLETS, DATA PORTS, INTERIOR DEVICES, ETC.

FOLLOW ELECTRICAL, MECHANICAL, AND TELECOMMUNICATION DRAWINGS.

G. REMOVE EXISTING SIGNAGE, COORDINATE WITH C.O.R. ANY REQUIRED NEW SIGNAGE.

H. FOLLOW MECHANICAL DRAWINGS FOR GRILL, DIFFUSER, AND REGISTER DEMOLITION, CAP AND

REPAIR AS REQUIRED.

I. RELOCATE EXISTING WATER, DRAIN, CONDENSATE, & STEAM LINES OUTSIDE NEW T.R., REFER TO

PLUMBING DRAWINGS FOR COORDINATION.

GENERAL NOTES ARCHITECTURAL

A. THE COR. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO PENETRATE WALLS. INSTALLED PER

MANUFACTURERS REQUIREMENTS TO MATCH RATING OF WALL.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. FOLLOW INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. FOLLOW SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

G. FOLLOW SHEET 000-AJ-605 FOR ALL FINISHES

GENERAL NOTES REFLECTED CEILING

A. RESTORE AFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.

B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.

GENERAL NOTES INFECTION CONTROL

A. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL, PRECAUTION CLASS III. WHERE CORRIDOR IS SHOWN WITH IN AREA OF

HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET THE MORE STRINGENT REQUIREMENT.

B. ALL OTHER AREAS ON THIS SHEET PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE C, LOW

RISK GROUP AND INFECTION CONTROL PRECAUTION CLASS II UNLESS OTHERWISE NOTED.

C. REFER TO SHEET GI003 FOR SYMBOLS AND ABBREVIATIONS.

GENERAL SHEET NOTES

KEYED NOTES - DEMOLITION

KEYED NOTES

KEYED NOTES - RENOVATION

Room Name

LEGEND

LEGACY ROOM NUMBER

SIGNAGE ROOM NUMBER

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AJ-011

C

ENLARGED PLANS BUILDING C

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

3/8" = 1'-0"D3

ENLARGED FIRST FLOOR PLAN - RENOVATION

RM 1C114C / 1A104B3/8" = 1'-0"D1

ENLARGED FIRST FLOOR PLAN - DEMOLITION

RM 1C114C / 1A104B 3/8" = 1'-0"D5

ENLARGED FIRST FLOOR RCP - DEMOLITION

RM 1C114C / 1A104B 3/8" = 1'-0"D7

ENLARGED FIRST FLOOR RCP - RENOVATION

RM 1C114C / 1A104B

128R PATCH EXISTING WALL WHERE DUCTWORK WAS REMOVED. MATCH EXISTING

CONSTRUCTION TYPE REFER TO MECHANICAL.

130R REPLACE CEILING GRIDS & TILE TO PREVIOUS CONDITION.

Revisions: Date:

94D EXISTING CEILING GRID AND TILE TO BE REMOVED AND REINSTALLED AS

NEEDED TO GIVE ACCESS TO NEW MECHANICAL UNITS. REFER TO

MECHANICAL DRAWINGS.

101D REMOVE EXISTING CEILING GRID & TILE FOR ACCESS TO DUCT REMOVAL.

SEE MECHANICAL.

S

C 4

C 4

C 4

TH

RE RE

O C

C R

C 4

C

TR

1B179

1B145

5D

79D

2D

93D

TR

1B179

1B145

107R

27R

47R

120R 4R

TR

1B179

1B145

1D

8D

20D

84D

82D

100D

7D

7D

102D

C7

01-AJ-014

F7

01-AJ-014

TR

1B179

1B145

2A

2A

2A

2A

2R 11R

12R

10R

10R

108R

10R

10R

7' - 3 1/2"

2A

18R

B

1R

19R

115R

47R

128R

127R

127R

127R

10R

119R

2R

47R

27R

SLOPE

F

IE

L D

V E

R

IF

Y W

I T H

E X

I S T

IN

G

D U

C T

S

10R

28R

47R

119R

27R

2R

GENERAL NOTE DEMOLITION

A. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION. BRING SIGNIFICANT

DISCREPANCIES TO THE ATTENTION OF THE COR. FOR REVIEW.

B. COORDINATE DEMOLITION TIMING WITH THE COR. PRIOR TO START.

C. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION, INCLUDING

MECHANICAL & FIRE SUPPRESSION SYSTEMS.

D. UPON COMPLETION OF DEMOLITION, PREPARE SUBSTRATE AS REQUIRED TO RECEIVE NEW FINISH

PER ARCHITECTURAL DRAWINGS. REPAIR ANY DAMAGE INCURRED DURING OR PRIOR TO THE

START OF WORK TO MATCH EXISTING CONDITION INCLUDING FIREPROOF MATERIALS.

E. SALVAGE AND RETURN TO C.O.R. EXISTING LIGHT FIXTURES TO BE REMOVED PER DRAWINGS.

F. EXISTING WALL MOUNTED DEVICES TO REMAIN UNLESS NOTED OTHERWISE, INCLUDED BUT NOT

LIMITED TO THERMOSTATS, LIGHT SWITCHES, OUTLETS, DATA PORTS, INTERIOR DEVICES, ETC.

FOLLOW ELECTRICAL, MECHANICAL, AND TELECOMMUNICATION DRAWINGS.

G. REMOVE EXISTING SIGNAGE, COORDINATE WITH C.O.R. ANY REQUIRED NEW SIGNAGE.

H. FOLLOW MECHANICAL DRAWINGS FOR GRILL, DIFFUSER, AND REGISTER DEMOLITION, CAP AND

REPAIR AS REQUIRED.

I. RELOCATE EXISTING WATER, DRAIN, CONDENSATE, & STEAM LINES OUTSIDE NEW T.R., REFER TO

PLUMBING DRAWINGS FOR COORDINATION.

GENERAL NOTES ARCHITECTURAL

A. THE COR. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO PENETRATE WALLS. INSTALLED PER

MANUFACTURERS REQUIREMENTS TO MATCH RATING OF WALL.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. FOLLOW INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. FOLLOW SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

G. FOLLOW SHEET 000-AJ-605 FOR ALL FINISHES

GENERAL NOTES REFLECTED CEILING

A. RESTORE AFFECTED CEILINGS TO ORIGINAL CONDITION UNLESS NOTED OTHERWISE.

B. NOT ALL CEILING DEVICES SHOWN, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

C. EXTEND EXISTING WALL ASSEMBLY WITHIN SCOPE TO THE DECK AS REQUIRED.

GENERAL NOTES INFECTION CONTROL

A. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL, PRECAUTION CLASS III. WHERE CORRIDOR IS SHOWN WITH IN AREA OF

HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET THE MORE STRINGENT REQUIREMENT.

B. ALL OTHER AREAS ON THIS SHEET PLAN SHALL BE CONSIDERED CONSTRUCTION TYPE C, LOW

RISK GROUP AND INFECTION CONTROL PRECAUTION CLASS II UNLESS OTHERWISE NOTED.

C. REFER TO SHEET GI003 FOR SYMBOLS AND ABBREVIATIONS.

GENERAL SHEET NOTES

KEYED NOTES - DEMOLITION

KEYED NOTES

KEYED NOTES - RENOVATION

Room Name

LEGEND

LEGACY ROOM NUMBER

SIGNAGE ROOM NUMBER

PROJECT NO.

BUILDING NO.

DRAWING NO.

PROJECT TITLE

FLS

ISSUE DATE CHECKED BY DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

STAMP

LOCATION

''1

CONSULTANTS

GDM of Oregon

1000 W. STEUBEN ST., UNIT 3

BINGEN, WA 98605

P: 541.436.4723

ADAM GODDIN, PE

WWW.GDM-AE.COM

FOR OFFICIAL USE ONLY (FOUO)

04-25-2023

FULLY

SPRINKLED

PROGRAM

CONTRACTING

ACTIVITY

CENTRAL (PCAC)

10% BASIS OF DESIGN 07.08.2022

35% SCHEMATIC DESIGN 11.10.2022

65% DESIGN DEVELOPMENT 01.13.2023

95% CONSTRUCTION DOCUMENTS 03.17.2023

100% FINAL BID DOCUMENTS 04.25.2023

A u to d e s k D o c s

/2 -0

N e w O rl e a n s

E H

R M

/2 -0

N

O L A

E H

R M

C o n c o u rs e

A rc h

P ro d u c ti o n -R

.r v t

01-AJ-014

C

ENLARGED PLANS BUILDING B

ES BS

VA NEW ORLEANS (EHRM) ELECTRONIC

HEALTH RECORD MODERNIZATION

INFRASTRUCTURE UPGRADES

2400 CANAL STREET, NEW ORLEANS, LA 70119

100% FINAL BID

DOCUMENTS

629-22-700

3/8" = 1'-0"F1

ENLARGED FIRST FLOOR RCP - DEMOLITION

ROOM 1B179 3/8" = 1'-0"F4

ENLARGED FIRST FLOOR RCP - RENOVATION

ROOM 1B179

3/8" = 1'-0"C1

ENLARGED FIRST FLOOR PLAN - DEMOLITION

ROOM 1B179 3/8" = 1'-0"C4

ENLARGED FIRST FLOOR PLAN - RENOVATION

ROOM 1B179 3/8" = 1'-0"C7

TR SECTION 1

ROOM 1B179

3/8" = 1'-0"F7

TR SECTION 2

ROOM 1B179

1R NEW DOOR, RE: SHEET 000-AJ-605 DOOR SCHEDULE.

2R INSTALL 4' X 8' 3/4" FIRE RATED PLYWOOD, VERTICAL, AC GRADE, 6" A.F.F. PER

WALL TYPE REFER TO SHEET 000-AJ-601. PAINT PLYWOOD W/ HIGH GLOSS, TWO

COATS, FIRE RESISTANT PAINT - COLOR WHITE. DO NOT PAINT OVER ONE FIRE

RATED STAMP ON EACH SHEET OF PLYWOOD.

4R CONTRACTOR TO PROVIDE APPROVAL SUBMITTAL FOR THE FIRE SPRINKLER

SYSTEM MODIFICATIONS IN EXISTING AND NEW TELECOMMUNICATION ROOMS

AND TELECOMMUNICATION SPACES. RELOCATE OR ADD NEW HEADS WHERE

REQUIRED, SPRINKLER HEADS TO BE WITHIN 12" OF THE CONCRETE

FLOOR/ROOF DECK ABOVE IN COMPLIANCE WITH NFPA13. COORDINATE

SPRINKLER SYSTEM SHUTDOWN/SCHEDULE WITH VA C.O.R. AND LOCAL FIRE

DEPARTMENT/AUTHORITY HAVING JURISDICTION.

10R 4" NEW VINYL BASE, COLOR TO MATCH EXISTING.

11R NEW STATIC DISSIPATIVE FLOORING TILE.

12R PAINT WALL FULL HEIGHT. FINISH TO MATCH EXISTING. PATCH AND REPAIR ANY

WALL DAMAGE TO MATCH EXISTING ADJACENT FINISHES AND TEXTURES.

18R NEW SEMI-RECESSED CLEAN AGENT FIRE EXTINGUISHER CABINET (DEPENDING

ON WALL CONDITION). MOUNT @ 48" TOP OF CABINET. FIELD VERIFICATION

REQUIRED.

19R NEW CARD READER AND KEYPAD.

27R NEW CABLE TRAY. RE: TELECOM.

28R NEW TELECOMMUNICATION EQUIPMENT, RE: TELECOM.

47R MECHANICAL UNIT, RE: MECHANICAL.

107R PATCH REPAIR CEILING AND TILE GRID AT NEW WALL LOCATION.

108R PAINT NEW WALLS TO MATCH EXISTING COLOR AND SCHEEN.

115R PAINT ENTIRE ROOM W/ HIGH GLOSS WHITE PAINT EXCEPT FOR PLYWOOD

WALLS.

119R NEW ROOF STRUCTURE REFER TO F5 SHEET 000-AJ-601.

120R 16" X 30" ACCESS HATCH IN PLYWOOD DECKING.

127R CUT PATCH AND REWORK EXISTING CARPET TILES AROUND NEW ROOM.

128R PATCH EXISTING WALL WHERE DUCTWORK WAS REMOVED. MATCH EXISTING

CONSTRUCTION TYPE REFER TO MECHANICAL.

1D REMOVE EXISTING DOOR AND FRAME

2D DEMOLISH EXISTING LAY-IN CEILING ASSEMBLY.

5D REMOVE EXISTING LIGHT FIXTURE, RETURN TO OWNER?. RE: ELECTRICAL

7D INFECTIONS CONTROL PLAN DETAIL, RE: F5/000-AJ-604

8D DEMOLISH EXISTING WALL.

20D REMOVE EXISTING FLOORING, VINYL AND BASE. PREP SLAB TO RECEIVE NEW

MATERIAL.

79D RELOCATE EXISTING DIFFUSER AND DUCTWORK. REFER TO MECHANICAL.

82D REMOVE FLOORING TO NEW WALL LOCATION PROTECT FLOOR TO REMAIN.

84D PROTECT EXISTING FLOORING MATERIAL.

93D PROTECT EXISTING SPRINKLER HEAD.

100D PROTECT EXISTING TELECOM EQUIPMENT FROM ALL CONSTRUCTION DEBRIS

UNTIL IT IS DEMOED.

102D PROTECT EXISTING ELECTRICAL PANEL FROM ALL CONSTRUCTION DEBRIS UNTIL

IT IS RELOCATED.

NORTH NORTH

NORTHNORTH

RE

RE

CR

F

OC

C 1

S

T ectonic Copyrig ht 2007

TR

1C228

1C1491D

20D

17D

7D

7D

E1

01-AJ-015

E3

01-AJ-015

TR

1C228

1C149

2R 11R 12R10R

18R

C

1R

19R

115R8R

47R

126R

128R

TR

1C228

1C149

5D 5D

79D 2D

93D 93D

TR

1C228

1C149 8R

27R

4R 4R

10R

2R

28R

27R

47R

GENERAL NOTE DEMOLITION

A. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION. BRING SIGNIFICANT

DISCREPANCIES TO THE ATTENTION OF THE COR. FOR REVIEW.

B. COORDINATE DEMOLITION TIMING WITH THE COR. PRIOR TO START.

C. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION, INCLUDING

MECHANICAL & FIRE SUPPRESSION SYSTEMS.

D. UPON COMPLETION OF DEMOLITION, PREPARE SUBSTRATE AS REQUIRED TO RECEIVE NEW FINISH

PER ARCHITECTURAL DRAWINGS. REPAIR ANY DAMAGE INCURRED DURING OR PRIOR TO THE

START OF WORK TO MATCH EXISTING CONDITION INCLUDING FIREPROOF MATERIALS.

E. SALVAGE AND RETURN TO C.O.R. EXISTING LIGHT FIXTURES TO BE REMOVED PER DRAWINGS.

F. EXISTING WALL MOUNTED DEVICES TO REMAIN UNLESS NOTED OTHERWISE, INCLUDED BUT NOT

LIMITED TO THERMOSTATS, LIGHT SWITCHES, OUTLETS, DATA PORTS, INTERIOR DEVICES, ETC.

FOLLOW ELECTRICAL, MECHANICAL, AND TELECOMMUNICATION DRAWINGS.

G. REMOVE EXISTING SIGNAGE, COORDINATE WITH C.O.R. ANY REQUIRED NEW SIGNAGE.

H. FOLLOW MECHANICAL DRAWINGS FOR GRILL, DIFFUSER, AND REGISTER DEMOLITION, CAP AND

REPAIR AS REQUIRED.

I. RELOCATE EXISTING WATER, DRAIN, CONDENSATE, & STEAM LINES OUTSIDE NEW T.R., REFER TO

PLUMBING DRAWINGS FOR COORDINATION.

GENERAL NOTES ARCHITECTURAL

A. THE COR. RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE

AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE OF THE FACILITY.

B. PROVIDE UL LISTED FIRESTOPPING AT ALL PENETRATION OF FIRE AND/OR SMOKE RATED WALLS.

C. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO PENETRATE WALLS. INSTALLED PER

MANUFACTURERS REQUIREMENTS TO MATCH RATING OF WALL.

D. ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT

BETWEEN CONSTRUCTION AREA VIA THE BUILDING HVAC SYSTEM.

E. FOLLOW INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

F. FOLLOW SHEET 000-AJ-601 FOR ALL DETAILS & PARTITION TYPES.

G. FOLLOW SHEET 000-AJ-605 FOR ALL FINISHES

GENERAL NOTES…