2.11 - Drawings 11 of 17 - 08-TN-011 to 00-TJ-028.pdf
PDF 21 MB Posted
- Solicitation number
- 36C77623B0038
About this file
This document provides details on a federal contract opportunity for infrastructure upgrades at a Veterans Affairs facility in New Orleans, Louisiana. The solicitation number is 36C77623B0038 and is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The opportunity is for construction services related to EHRM infrastructure upgrades at the New Orleans location. Products and services required include general construction work to upgrade existing infrastructure systems. The estimated award date is not provided but the response deadline for this solicitation is [date]. Relevant set-aside provisions or considerations for small businesses are not outlined.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UP
UPDN
B B
B
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
B B
B B
B B
B B
B B
B B
B B
B B
B
B
B
B B
B B
B B
B
B B
B
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
B B
B B
B B
B B
B B
B B
B B
B B
B
B B
B B
B B
B
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
OFF
SUP
1P102L
VESTIBULE
1P113
SHELL
1P113A
OFF CH
1P103E
OFF DEP
1P103A
BID OPEN
1P103B
STOR
1P106
CONF
1P105
CH LOG
1P107C
TECH
1P107A
OFF
1P102Q
OFF
1P102P
OFF
1P102N
INV
1P102M
INV
1P102K
INV
1P102J
INV
1P102H
INV
1P102G
INV
1P102F
OFF
1P101F
SUP
1P107F
ASST CH
1P107B
OFF
1P101G
OFF
1P101H
OFF
1P101J
STOR
1P101D
OFF
1P101E
INV
1P101B
INV
1P101A
RD PI
1P101N
RD PI
1P101M
CONF
1P108
TR
1P110
INV
1P102D
INV
1P102C
GROUP
1P112B
CLASS
1P112C
GROUP
1P112D
TLT
1P109
TLT
1P111
RECY
1P115A
LAB STOR
1P115B
SEC
1P100B
ELEC
1P115C
BIO MED
1P114 EMS
1P116
DOCK
1P115
REC
1P100C
COPY
1P101C
RECP + W
1P101
TECH
1P107D
CPY
1P102E
MULTI PURP
1P112
WAITING
1P100D
GROUP
1P112A
REC
1P102PSA, RN
1P102R
DATA WORK
1P101L
HK
1P104
ELEC
1P116A
RAD WST
1P115E
STOR
1P115D
COPY
1P107E
SEC WAIT
1P107
SEC
1P103
VESTIBULE
1P100A
CLER TECH
1P103D
HS CUBES
1P101K
CORR
1P-C02
CORR
1P-C06
CORR
1P-C07
CORR
1P-C01
CORR
1P-C05
CORR
1P-C03
CORR
1P-C04
ALCOVE
1F-CO4A
STAIR
STP-2
STAIR
STP-1
SHAFT UTILITY ACCESS
1P115H
ELEV
PS-02
ELEV
PS-01
SHOWER
1P109A
SHOWER
1P111A
ELEC
1P1025
BIO HAZ WST
1P115F
STORAGE
1P112G
LOBBY
1P100
LVSR
1P110A
CORR
1P-C11
SHELL
1P113A
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
08-TN-011
(E)CABLE TRAY
SEE SITE PLAN ON
SHEET 00-TS-005
FOR CONTINUATION
(4)24-STR SM (OS2)
(3)24-STR SM (OS2)
(3)24-STR SM (OS2)
4"C. UP TO 2ND FLOOR
(1)24-STR SM (OS2)(4)24-STR SM (OS2)
4"C.
(4)24-STR SM (OS2)
(E)1P140-RK1
(E)1P140-RK2
(E)1P140-RK3
(E)1P140-RK4
TR
1P110
1P140
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
08-TN-011
OVERALL FIRST FLOOR TELECOMM PLAN -
BLDG. 08
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 08 TELECOMM OVERALL PLAN - LEVEL 1
GENERAL NOTES
1. CONTRACTOR TO PROVIDE ALL CONDUIT SLEEVES AND CONDUIT. CONDUIT SLEEVES TO BE
SIZED AS REQUIRED FOR ROUTING OF TELECOMMUNICATIONS CABLING THROUGH WALLS
AND NON ACCESSIBLE CEILING AREAS. CONDUIT SLEEVES SHALL BE HILTI SPEED SLEEVES.
CONDUIT SIZE IS TO BE AS NOTED.
2. FOR NEW CONDUIT INSTALLATIONS THAT PENETRATE THROUGH EXISTING CONCRETE
WALLS AND FLOORS, CONTRACTOR SHALL PROVIDE ALL CORE-DRILLING, SEALING, AND
FIRE STOPPING AS REQUIRED.
3. ALL NEW FIBER SHALL BE REROUTED IN NEW INNERDUCT. INNERDUCT SHALL BE UTILIZED
FOR ROUTING FROM POINT OF ENTRY TO TERMINATION RACK AND SHALL UTILIZE NEW AND
EXISTING PATHWAYS AS REQUIRED.
4. ALL FIBER OPTIC CABLES ARE TO BE FIELD TERMINATED ON BOTH ENDS WITH SPLICE
CASSETTE CONNECTORS. ALL LENGTHS LISTED IN MATRIX ON SHEET 000-TG-001, ARE
APPROXIMATE. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO VERIFY REQUIRED
LENGTHS PRIOR TO PURCHASE OF FACTOR TERMINATED CABLES. CONTRACTOR SHALL
PROVIDE 10' OF ADDITIONAL LENGTH AT EACH END AND 16' WITHIN EACH VAULT FOR
SERVICE LOOPS.
5. TERMINATE FIBER CABLING IN NEW FIBER PATCH PANELS IN TELECOMMUNICATION RACKS.
6. CONTRACTOR TO PROVIDE NEW J-HOOKS SIZED AS REQUIRED FOR ROUTING OF FIBER
OPTIC CABLE IN ACCESSIBLE SPACES AS SHOWN. PROVIDE ALL APPURTENANCES FOR
INSTALLATION OF J-HOOKS.
7. IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ON SITE.
8. PROVIDE 3/4" AC GRADE(OR BETER) PLYWOOD ON ALL WALLS IN TR ROOMS. PLYWOOD WILL
BE FIRE RETARDANT AND COATED WITH TWO COATS OF FIRE RETARDANT PAINT. THE
BOTTOM OF THE PLYWOOD SHOULD BE MOUNTED 6" AFF.
9. CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD", OR ANY PORTS
WITHOUT AN ADDRESS, AND VERIFY AN OUTLET. FOR PRICING PURPOSES, ASSUME A
MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
10. DRAWING PLANS INDICATE NUMBER OF DROPS IN AREAS THAT ARE SERVED EXACT
LOCATION OF DROPS IN EACH AREA SHALL BE CONFIRMED ON SITE.
11. CONTRACTOR TO PROVIDE ACCESS PANELS IN HARD CEILINGS AS REQUIRED.
12. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
13. FOR ENLARGED PLAN CALLOUTS WE ANNOTATED CURRENT ROOM NUMBER. FLOOR PLAN
ROOM NUMBERS SHOW LEGACY ROOM NUMBERS.
1/4" = 1'-0"2
ENLARGED TELECOMM PLAN - TR 1P140
PLAN NOTES
1 EXISTING TR RACKS TO REMAIN. PROVIDE FIBER ENCLOSURES, UPS, AND PDU'S. SEE RACK
EQUIPMENT SCHEDULE ON THIS SHEET FOR ADDITONAL INFORMATION.
2 PROVIDE HILTI FIRESTOP SPEED SLEEVE.
3 PROVIDE RACK BONDING BUSBAR(RBB) IN EXISTING 2-POST RACK. PROVIDE BONDING AS
REQUIRED. SEE BONDING DETAILS ON SHEET TJ-007 FOR ADDITIONAL INFORMATION.
4 PROVIDE VERTICAL CABLE SUPPORTS FROM CONDUIT/SLEEVE TO COMMUNICATION RACK.
RACK EQUIPMENT SCHEDULE - EXISTING TR WITH/ (4)EXISTING RACKS
EQUIPMENT QTY TYPE PART#
UPS 4 5 KVA EATON #ZC0517708100000 OR APPROVED
EQUAL, WITH HEAVY DUTY SHELF EATON
#ZC0517708100000
FIBER ENCLOSURE NOTE 1 NOTE 1 NOTE 1
PDU 8 VERTICAL PDU APC #8861, WITH MOUNTING BRACKETS
#KIT-MB-41 OR APPROVED EQUAL
ZONE PDU 1 60 AMP HORIZONTAL
ZONE PDU
#ZPDS-208V60A-HW-6L21-20R OR
APPROVED EQUAL
NOTES: SEE RACK ELEVATIONS FOR EXACT LOCATIONS OF EACH PIECE OF EQUIPMENT.
1. SEE FIBER ONE LINE DIAGRAMS FOR ADDITIONAL INFORMATION.
Revisions: Date:
UP
DN
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
HS OFFICE
2P104C
HS OFFICE
2P104B
COPY/ STG
2P104A
HS WKSTNS
2P105
HS WKSTNS
2P106
HS WKSTNS
2P104
STAIR
STP-2
STAIR
STP-1
ELEV
PS-02
ELEV
PS-01
LVSR
2P100A
ELEC
2P169
ELEC
2P137
TC
2P139
MIC D
2P139A
TC
2P141
MIC D
2P135A
FRZ UL
2P143
REFRIG/FRZ
2P149A
ELEC MIC
2P150
TC
2P145
TC
2P147
FZ-20
2P149B
TC
2P135B
MIC D
2P135BB
PI
2P134
PI
2P132
PI
2P130
PI
2P128
PI
2P126
PI
2P124
PI
2P122
PI CONF
2P120
TC
2P151
CELL
S
2P153D
TC
2P153C
HPLC
2P153B
MIC D
2P153A
MIC D
2P157A
TC
2P157
TC
2P155
IM HIST
2P159
HK
2P161
GLASS WASH
2P163
CELL BANK
2P165
LER
2P135
LER
2P149
LER
2P153
TL
2P116
TL
2P115
LAB 1
2P138
LAB 4 & 5
2P152
LAB 6
2P162
LAB 7 & 8
2P168
CYL
2P167
LAB 2
2P142
LAB 3
2P148
CORR
2P-C04.1
CORR
2P-C02
CORR
2P-C01A
CORR
2P-C01
CORR
2P-C03A
EQUIP RM
2P163AELEC MIC
EQUIP
2P150A
LAB 7 & 8 HOODS
2P168B
LAB 7 & 8 ENTRY
2P168A LAB 7 & 8 HOODS
2P168C
LAB 6 HODDS
2P162B
LAB 1 ENTRY
2P138A
LAB 1 FUME HOOD
2P138B
LAB 2 ENTRY
2P142A
LAB 2 HOODS
2P142B
LAB 3 ENTRY
2P148A
LAB 3 HOODS
2P148B
LAB 4 & 5 HOODS
2P152B
LAB 4 & 5 ENTRY
2P152A
LAB 4 & 5 HOODS
2P152C
LAB 4 & 5 HOODS
2P152D
LAB 4 & 5 HOODS
2P152E
LAB 6 ENTRY
2P162A
STAIR
STAIR
ELEV
ELEV
CORR
2P-C04.2
WORK/COLAB
2P100B
AISLE
2P-C01B
CORR
2P-C03B
TR
2P100C
COPY/ STG
HS OFFICE
HS OFFICE
HS WKSTNS
HS WKSTNS
HS WKSTNS
PI
HS
WORK/ COLAB
PI EQ
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
08-TN-021
(E)CABLE TRAY
(E)2P120A-RK1
(E)2P120A-RK2
(E)2P120A-RK3
(E)2P120A-RK4
TR
2P100C
2P120A
(2)24-STR SM (OS2)
4"C. UP TO 3RD FLOOR
(1)24-STR SM (OS2)
3 4
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
08-TN-021
OVERALL SECOND FLOOR TELECOMM
PLAN - BLDG. 08
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 08 TELECOMM OVERALL PLAN - LEVEL 2
GENERAL NOTES
1. CONTRACTOR TO PROVIDE ALL CONDUIT SLEEVES AND CONDUIT. CONDUIT SLEEVES TO BE
SIZED AS REQUIRED FOR ROUTING OF TELECOMMUNICATIONS CABLING THROUGH WALLS
AND NON ACCESSIBLE CEILING AREAS. CONDUIT SLEEVES SHALL BE HILTI SPEED SLEEVES.
CONDUIT SIZE IS TO BE AS NOTED.
2. FOR NEW CONDUIT INSTALLATIONS THAT PENETRATE THROUGH EXISTING CONCRETE
WALLS AND FLOORS, CONTRACTOR SHALL PROVIDE ALL CORE-DRILLING, SEALING, AND
FIRE STOPPING AS REQUIRED.
3. ALL NEW FIBER SHALL BE REROUTED IN NEW INNERDUCT. INNERDUCT SHALL BE UTILIZED
FOR ROUTING FROM POINT OF ENTRY TO TERMINATION RACK AND SHALL UTILIZE NEW AND
EXISTING PATHWAYS AS REQUIRED.
4. ALL FIBER OPTIC CABLES ARE TO BE FIELD TERMINATED ON BOTH ENDS WITH SPLICE
CASSETTE CONNECTORS. ALL LENGTHS LISTED IN MATRIX ON SHEET 000-TG-001, ARE
APPROXIMATE. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO VERIFY REQUIRED
LENGTHS PRIOR TO PURCHASE OF FACTOR TERMINATED CABLES. CONTRACTOR SHALL
PROVIDE 10' OF ADDITIONAL LENGTH AT EACH END AND 16' WITHIN EACH VAULT FOR
SERVICE LOOPS.
5. TERMINATE FIBER CABLING IN NEW FIBER PATCH PANELS IN TELECOMMUNICATION RACKS.
6. CONTRACTOR TO PROVIDE NEW J-HOOKS SIZED AS REQUIRED FOR ROUTING OF FIBER
OPTIC CABLE IN ACCESSIBLE SPACES AS SHOWN. PROVIDE ALL APPURTENANCES FOR
INSTALLATION OF J-HOOKS.
7. IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ON SITE.
8. PROVIDE 3/4" AC GRADE(OR BETER) PLYWOOD ON ALL WALLS IN TR ROOMS. PLYWOOD WILL
BE FIRE RETARDANT AND COATED WITH TWO COATS OF FIRE RETARDANT PAINT. THE
BOTTOM OF THE PLYWOOD SHOULD BE MOUNTED 6" AFF.
9. CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD", OR ANY PORTS
WITHOUT AN ADDRESS, AND VERIFY AN OUTLET. FOR PRICING PURPOSES, ASSUME A
MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
10. DRAWING PLANS INDICATE NUMBER OF DROPS IN AREAS THAT ARE SERVED EXACT
LOCATION OF DROPS IN EACH AREA SHALL BE CONFIRMED ON SITE.
11. CONTRACTOR TO PROVIDE ACCESS PANELS IN HARD CEILINGS AS REQUIRED.
12. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
13. FOR ENLARGED PLAN CALLOUTS WE ANNOTATED CURRENT ROOM NUMBER. FLOOR PLAN
ROOM NUMBERS SHOW LEGACY ROOM NUMBERS.
1/4" = 1'-0"2
ENLARGED TELECOMM PLAN - TR 2P120A
PLAN NOTES
1 EXISTING TR RACKS TO REMAIN. PROVIDE FIBER ENCLOSURES, UPS, AND PDU'S. SEE RACK
EQUIPMENT SCHEDULE ON THIS SHEET FOR ADDITONAL INFORMATION.
2 PROVIDE RACK BONDING BUSBAR(RBB) IN EXISTING 2-POST RACK. PROVIDE BONDING AS
REQUIRED. SEE BONDING DETAILS ON SHEET TJ-007 FOR ADDITIONAL INFORMATION.
3 PROVIDE HILTI FIRESTOP SPEED SLEEVE.
4 PROVIDE VERTICAL CABLE SUPPORTS FROM CONDUIT/SLEEVE TO COMMUNICATION RACK.
RACK EQUIPMENT SCHEDULE - EXISTING TR WITH/ (4)EXISTING RACKS
EQUIPMENT QTY TYPE PART#
UPS 4 5 KVA EATON #ZC0517708100000 OR APPROVED
EQUAL, WITH HEAVY DUTY SHELF EATON
#ZC0517708100000
FIBER ENCLOSURE NOTE 1 NOTE 1 NOTE 1
PDU 8 VERTICAL PDU APC #8861, WITH MOUNTING BRACKETS
#KIT-MB-41 OR APPROVED EQUAL
ZONE PDU 1 60 AMP HORIZONTAL
ZONE PDU
#ZPDS-208V60A-HW-6L21-20R OR
APPROVED EQUAL
NOTES: SEE RACK ELEVATIONS FOR EXACT LOCATIONS OF EACH PIECE OF EQUIPMENT.
DN UP
UP
UP
J
J
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
HS OFFICE
3P202B
HS CONF
3P101A
COPY
3P202A
HS WKSTNS
3P202
HS OFFICE
3P202C
HS WKSTNS
3P104
HS WRKSTNS
3P101
COLLABORATION
3P202D
STAIR
STP-2
STAIR
STP-1
ELEV
PS-02
ELEV
PS-01
STAIR
STAIR
ELEV
ELEV
TC
3P139
MIC D
3P139A
ELEC
3P137
ELEC
3P173
LVSR
3P100A
PI
3P134
PI
3P132
PI
3P130
PI
3P128
PI
3P126
PI
3P124
PI
3P122
PI CONF
3P120
OFF
3P107
TL
3P105
TL
3P103
WORK/ COLAB
3P100
LER
3P135
LER
3P149
LER
3P155
TC
3P141
FRZ UL
3P143
MIC D
3P135A
COLD
3P149A
TC
3P145
TC
3P147
TC
3P153
MIC D
3P153AMIC D
3P149B
TC
3P135B
MIC D
3P135BB
TC
3P155C
TC
3P155B
EQ ROOM
3P155A
TC
3P157
CON FOC
3P159
IM HIST
3P161
HK
3P163
RAD LAB
3P165
TC
3P167
FLAM STOR
3P171
ACID STOR
3P169
LAB 11
3P148
LAB 14
3P162
LAB 10
3P142LAB 9
3P138
LAB 15
3P168
SERV
3P102
LABS 12 & 13
3P152
CORR
3P-C20
CORR
3P-C04
CORR
3P-C04A
CORR
3P-C01
CORR
3P-C03A
CORR
3P-C02
LAB 9 ENTRY
3P138A
LAB 9 HOODS
3P138B
LAB 10 ENTRY
3P142A LAB 10 HOODS
3P142B
LAB 11 ENTRY
3P148A LAB 11 HOODS
3P148B
LABS 12 & 13 HOODS
3P152B
LABS 12 & 13 ENTRY
3P152A
LABS 12 & 13 HOODS
3P152C
LABS 12 & 13 HOODS
3P152D
LABS 12 & 13 HOODS
3P152E
LAB 14 ENTRY
3P162A LAB 14 HOODS
3P162B
LAB 15 HOODS
3P168B
LAB 15 ENTRY
3P168A LAB 15 HOODS
3P168C
STAIR
STAIR
ELEV
ELEV
CORR
CP-CO3B
TR
3P100C
COLLABORATION
3P202D
HS WKSTNS
3P104
HS WKSTNS
COPY
HS OFFICE
HS OFFICE
HS WKSTNS
HS CONF
MASS SP
HS
HS
LOUNGE
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
08-TN-031
(E)CABLE TRAY
(1)24-STR SM (OS2)
4"C. UP TO 4TH FLOOR
(E)3P102A-RK1
(E)3P102A-RK2
(E)3P102A-RK3
(E)3P102A-RK4
TR
3P100C
3P102A
(E)SBB
(1)24-STR SM (OS2)
(1)24-STR SM (OS2)
4"C. UP TO 4TH FLOOR
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
08-TN-031
OVERALL THIRD FLOOR TELECOMM PLAN -
BLDG. 08
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 08 TELECOMM OVERALL PLAN - LEVEL 3
GENERAL NOTES
1. CONTRACTOR TO PROVIDE ALL CONDUIT SLEEVES AND CONDUIT. CONDUIT SLEEVES TO BE
SIZED AS REQUIRED FOR ROUTING OF TELECOMMUNICATIONS CABLING THROUGH WALLS
AND NON ACCESSIBLE CEILING AREAS. CONDUIT SLEEVES SHALL BE HILTI SPEED SLEEVES.
CONDUIT SIZE IS TO BE AS NOTED.
2. FOR NEW CONDUIT INSTALLATIONS THAT PENETRATE THROUGH EXISTING CONCRETE
WALLS AND FLOORS, CONTRACTOR SHALL PROVIDE ALL CORE-DRILLING, SEALING, AND
FIRE STOPPING AS REQUIRED.
3. ALL NEW FIBER SHALL BE REROUTED IN NEW INNERDUCT. INNERDUCT SHALL BE UTILIZED
FOR ROUTING FROM POINT OF ENTRY TO TERMINATION RACK AND SHALL UTILIZE NEW AND
EXISTING PATHWAYS AS REQUIRED.
4. ALL FIBER OPTIC CABLES ARE TO BE FIELD TERMINATED ON BOTH ENDS WITH SPLICE
CASSETTE CONNECTORS. ALL LENGTHS LISTED IN MATRIX ON SHEET 000-TG-001, ARE
APPROXIMATE. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO VERIFY REQUIRED
LENGTHS PRIOR TO PURCHASE OF FACTOR TERMINATED CABLES. CONTRACTOR SHALL
PROVIDE 10' OF ADDITIONAL LENGTH AT EACH END AND 16' WITHIN EACH VAULT FOR
SERVICE LOOPS.
5. TERMINATE FIBER CABLING IN NEW FIBER PATCH PANELS IN TELECOMMUNICATION RACKS.
6. CONTRACTOR TO PROVIDE NEW J-HOOKS SIZED AS REQUIRED FOR ROUTING OF FIBER
OPTIC CABLE IN ACCESSIBLE SPACES AS SHOWN. PROVIDE ALL APPURTENANCES FOR
INSTALLATION OF J-HOOKS.
7. IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ON SITE.
8. PROVIDE 3/4" AC GRADE(OR BETER) PLYWOOD ON ALL WALLS IN TR ROOMS. PLYWOOD WILL
BE FIRE RETARDANT AND COATED WITH TWO COATS OF FIRE RETARDANT PAINT. THE
BOTTOM OF THE PLYWOOD SHOULD BE MOUNTED 6" AFF.
9. CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD", OR ANY PORTS
WITHOUT AN ADDRESS, AND VERIFY AN OUTLET. FOR PRICING PURPOSES, ASSUME A
MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
10. DRAWING PLANS INDICATE NUMBER OF DROPS IN AREAS THAT ARE SERVED EXACT
LOCATION OF DROPS IN EACH AREA SHALL BE CONFIRMED ON SITE.
11. CONTRACTOR TO PROVIDE ACCESS PANELS IN HARD CEILINGS AS REQUIRED.
12. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
13. FOR ENLARGED PLAN CALLOUTS WE ANNOTATED CURRENT ROOM NUMBER. FLOOR PLAN
ROOM NUMBERS SHOW LEGACY ROOM NUMBERS.
1/4" = 1'-0"2
ENLARGED TELECOMM PLAN - TR 3P102A
RACK EQUIPMENT SCHEDULE - EXISTING TR WITH/ (4)EXISTING RACKS
EQUIPMENT QTY TYPE PART#
UPS 4 5 KVA EATON #ZC0517708100000 OR APPROVED
EQUAL, WITH HEAVY DUTY SHELF EATON
#ZC0517708100000
FIBER ENCLOSURE NOTE 1 NOTE 1 NOTE 1
PDU 8 VERTICAL PDU APC #8861, WITH MOUNTING BRACKETS
#KIT-MB-41 OR APPROVED EQUAL
ZONE PDU 1 60 AMP HORIZONTAL
ZONE PDU
#ZPDS-208V60A-HW-6L21-20R OR
APPROVED EQUAL
NOTES: SEE RACK ELEVATIONS FOR EXACT LOCATIONS OF EACH PIECE OF EQUIPMENT.
1. SEE FIBER ONE LINE DIAGRAMS FOR ADDITIONAL INFORMATION.
PLAN NOTES
1 EXISTING TR RACKS TO REMAIN. PROVIDE FIBER ENCLOSURES, UPS, AND PDU'S. SEE RACK
EQUIPMENT SCHEDULE ON THIS SHEET FOR ADDITONAL INFORMATION.
2 PROVIDE RACK BONDING BUSBAR(RBB) IN EXISTING 2-POST RACK. PROVIDE BONDING AS
REQUIRED. SEE BONDING DETAILS ON SHEET TJ-007 FOR ADDITIONAL INFORMATION.
3 PROVIDE HILTI FIRESTOP SPEED SLEEVE.
4 PROVIDE VERTICAL CABLE SUPPORTS FROM CONDUIT/SLEEVE TO COMMUNICATION RACK.
DNUP
UP
DN
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
STAIR
STP-2
STAIR
STP-1
ELEV
PS-02
ELEV
PS-01
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
HS
4P102A
HS
4P105A
HS
4P101A
HS
4P103A
HOLD
4P327
TREAT
4P329
HOLD RABBIT
4P331
TREAT
4P333
HOLD RABBIT
4P335
ELEC
4P115B
HK
4P113
HOLD
4P302A
HOLD
4P323
TREAT
4P321
HOLD
4P317
HOLD
4P324
TREAT
4P322
ISO HOLDING
4P320B
ISO HOLDING
ANTE-ROOM
4P320A
HOLD
4P316
OR SUP
4P318D
OR
4P318C
GOWN PREP
4P318B
FEED & BED STOR
4P314B
CLEAN CAGE
4P314A
CLEAN CAGE WASH
4P314
SOIL CAGE WASH
4P304
WOMEN LOCKER
4P300F
VET OFF
4P300B
LOUNGE
4P300
OFF
4P300A
MEN LOCKER
4P300C
HAZ WASTE STOR
4P303
FRZ/STOR
4P305
TR
4P103
WATER SYS
4P311
CARC HOLD
4P309
NECRO
4P307
EQUIP
4P305AUNASSIGNED
4P315
ENVIRO PROC
4P313A
ENV HOLD
4P313
ELEC
4P301
TL
4P104
TL
4P102
REC + W
4P101
RECPT
4P100
X RAY
4P318A
UNASSIGNED
4P100A
HK
4P319
QUAR HOLD
4P302B
DIAG HOLD
4P302C
CORR
4P-C03
CORR
4P-C03A
CORR
4P-C03B
CORR
4P-C01
CORR
4P-C02
STAIR
STAIR
ELEV
ELEV
T/S
4P300E
T/S
4P300D
VESTIBULE
4P-C01A
VESTIBULE
4P-C03C
UNAS
4P106A
VESTIBULE
4P115A
CORR
4P-CO1B
LOBBY
4P100B
LVSR
4P103B
ACOS CONF
4P204
FILE/COPY
4P203
OFFICE
4P202E
RCO
AO
CORR
OFFICE
ACOS OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STAIR
STAIR
ELEV
ELEV
08-TN-041
(E)CABLE TRAY
(E)4P103-RK1
(E)4P103-RK2
(E)4P103-RK3
(E)4P103-RK4
TR
4P103
4P103
(1)24-STR SM (OS2)
4"C. FROM 3RD FLOOR
3 4
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
08-TN-041
OVERALL FOURTH FLOOR TELECOMM
PLAN - BLDG. 08
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 08 TELECOMM OVERALL PLAN - LEVEL 4
GENERAL NOTES
1. CONTRACTOR TO PROVIDE ALL CONDUIT SLEEVES AND CONDUIT. CONDUIT SLEEVES TO BE
SIZED AS REQUIRED FOR ROUTING OF TELECOMMUNICATIONS CABLING THROUGH WALLS
AND NON ACCESSIBLE CEILING AREAS. CONDUIT SLEEVES SHALL BE HILTI SPEED SLEEVES.
CONDUIT SIZE IS TO BE AS NOTED.
2. FOR NEW CONDUIT INSTALLATIONS THAT PENETRATE THROUGH EXISTING CONCRETE
WALLS AND FLOORS, CONTRACTOR SHALL PROVIDE ALL CORE-DRILLING, SEALING, AND
FIRE STOPPING AS REQUIRED.
3. ALL NEW FIBER SHALL BE REROUTED IN NEW INNERDUCT. INNERDUCT SHALL BE UTILIZED
FOR ROUTING FROM POINT OF ENTRY TO TERMINATION RACK AND SHALL UTILIZE NEW AND
EXISTING PATHWAYS AS REQUIRED.
4. ALL FIBER OPTIC CABLES ARE TO BE FIELD TERMINATED ON BOTH ENDS WITH SPLICE
CASSETTE CONNECTORS. ALL LENGTHS LISTED IN MATRIX ON SHEET 000-TG-001, ARE
APPROXIMATE. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO VERIFY REQUIRED
LENGTHS PRIOR TO PURCHASE OF FACTOR TERMINATED CABLES. CONTRACTOR SHALL
PROVIDE 10' OF ADDITIONAL LENGTH AT EACH END AND 16' WITHIN EACH VAULT FOR
SERVICE LOOPS.
5. TERMINATE FIBER CABLING IN NEW FIBER PATCH PANELS IN TELECOMMUNICATION RACKS.
6. CONTRACTOR TO PROVIDE NEW J-HOOKS SIZED AS REQUIRED FOR ROUTING OF FIBER
OPTIC CABLE IN ACCESSIBLE SPACES AS SHOWN. PROVIDE ALL APPURTENANCES FOR
INSTALLATION OF J-HOOKS.
7. IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ON SITE.
8. PROVIDE 3/4" AC GRADE(OR BETER) PLYWOOD ON ALL WALLS IN TR ROOMS. PLYWOOD WILL
BE FIRE RETARDANT AND COATED WITH TWO COATS OF FIRE RETARDANT PAINT. THE
BOTTOM OF THE PLYWOOD SHOULD BE MOUNTED 6" AFF.
9. CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD", OR ANY PORTS
WITHOUT AN ADDRESS, AND VERIFY AN OUTLET. FOR PRICING PURPOSES, ASSUME A
MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
10. DRAWING PLANS INDICATE NUMBER OF DROPS IN AREAS THAT ARE SERVED EXACT
LOCATION OF DROPS IN EACH AREA SHALL BE CONFIRMED ON SITE.
11. CONTRACTOR TO PROVIDE ACCESS PANELS IN HARD CEILINGS AS REQUIRED.
12. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
13. FOR ENLARGED PLAN CALLOUTS WE ANNOTATED CURRENT ROOM NUMBER. FLOOR PLAN
ROOM NUMBERS SHOW LEGACY ROOM NUMBERS.
1/4" = 1'-0"2
ENLARGED TELECOMM PLAN - TR 4P103
RACK EQUIPMENT SCHEDULE - EXISTING TR WITH/ (4)EXISTING RACKS
EQUIPMENT QTY TYPE PART#
UPS 4 5 KVA EATON #ZC0517708100000 OR APPROVED
EQUAL, WITH HEAVY DUTY SHELF EATON
#ZC0517708100000
FIBER ENCLOSURE NOTE 1 NOTE 1 NOTE 1
PDU 8 VERTICAL PDU APC #8861, WITH MOUNTING BRACKETS
#KIT-MB-41 OR APPROVED EQUAL
ZONE PDU 1 60 AMP HORIZONTAL
ZONE PDU
#ZPDS-208V60A-HW-6L21-20R OR
APPROVED EQUAL
NOTES: SEE RACK ELEVATIONS FOR EXACT LOCATIONS OF EACH PIECE OF EQUIPMENT.
1. SEE FIBER ONE LINE DIAGRAMS FOR ADDITIONAL INFORMATION.
PLAN NOTES
1 EXISTING TR RACKS TO REMAIN. PROVIDE FIBER ENCLOSURES, UPS, AND PDU'S. SEE RACK
EQUIPMENT SCHEDULE ON THIS SHEET FOR ADDITONAL INFORMATION.
2 PROVIDE RACK BONDING BUSBAR(RBB) IN EXISTING 2-POST RACK. PROVIDE BONDING AS
REQUIRED. SEE BONDING DETAILS ON SHEET TJ-007 FOR ADDITIONAL INFORMATION.
3 PROVIDE HILTI FIRESTOP SPEED SLEEVE.
4 PROVIDE VERTICAL CABLE SUPPORTS FROM CONDUIT/SLEEVE TO COMMUNICATION RACK.
DN UP
DN
DN
DN
DN
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
MECHANICAL
5P-CO47
UNOCCUPIED
5P-CO48
TOWER ACCESS
5P-CO49
UNOCCUPIED
5P-CO46
STAIR
STP-2
STAIR
STP-1
ELEV
PS-02
ELEV
PS-01
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
STAIR
STAIR
ELEV
ELEV
EMER ELEC
5P101
ELEC SW GEAR
5P100
MECH PENT
5P102
STAIR
STAIR
ELEV
ELEV
VEST
5P200
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
08-TN-051
OVERALL FIFTH FLOOR TELECOMM PLAN -
BLDG. 08
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 08 TELECOMM OVERALL PLAN - LEVEL 5
GENERAL NOTES
1. CONTRACTOR TO PROVIDE ALL CONDUIT SLEEVES AND CONDUIT. CONDUIT SLEEVES TO BE
SIZED AS REQUIRED FOR ROUTING OF TELECOMMUNICATIONS CABLING THROUGH WALLS
AND NON ACCESSIBLE CEILING AREAS. CONDUIT SLEEVES SHALL BE HILTI SPEED SLEEVES.
CONDUIT SIZE IS TO BE AS NOTED.
2. FOR NEW CONDUIT INSTALLATIONS THAT PENETRATE THROUGH EXISTING CONCRETE
WALLS AND FLOORS, CONTRACTOR SHALL PROVIDE ALL CORE-DRILLING, SEALING, AND
FIRE STOPPING AS REQUIRED.
3. ALL NEW FIBER SHALL BE REROUTED IN NEW INNERDUCT. INNERDUCT SHALL BE UTILIZED
FOR ROUTING FROM POINT OF ENTRY TO TERMINATION RACK AND SHALL UTILIZE NEW AND
EXISTING PATHWAYS AS REQUIRED.
4. ALL FIBER OPTIC CABLES ARE TO BE FIELD TERMINATED ON BOTH ENDS WITH SPLICE
CASSETTE CONNECTORS. ALL LENGTHS LISTED IN MATRIX ON SHEET 000-TG-001, ARE
APPROXIMATE. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO VERIFY REQUIRED
LENGTHS PRIOR TO PURCHASE OF FACTOR TERMINATED CABLES. CONTRACTOR SHALL
PROVIDE 10' OF ADDITIONAL LENGTH AT EACH END AND 16' WITHIN EACH VAULT FOR
SERVICE LOOPS.
5. TERMINATE FIBER CABLING IN NEW FIBER PATCH PANELS IN TELECOMMUNICATION RACKS.
6. CONTRACTOR TO PROVIDE NEW J-HOOKS SIZED AS REQUIRED FOR ROUTING OF FIBER
OPTIC CABLE IN ACCESSIBLE SPACES AS SHOWN. PROVIDE ALL APPURTENANCES FOR
INSTALLATION OF J-HOOKS.
7. IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ON SITE.
8. PROVIDE 3/4" AC GRADE(OR BETER) PLYWOOD ON ALL WALLS IN TR ROOMS. PLYWOOD WILL
BE FIRE RETARDANT AND COATED WITH TWO COATS OF FIRE RETARDANT PAINT. THE
BOTTOM OF THE PLYWOOD SHOULD BE MOUNTED 6" AFF.
9. CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD", OR ANY PORTS
WITHOUT AN ADDRESS, AND VERIFY AN OUTLET. FOR PRICING PURPOSES, ASSUME A
MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
10. DRAWING PLANS INDICATE NUMBER OF DROPS IN AREAS THAT ARE SERVED EXACT
LOCATION OF DROPS IN EACH AREA SHALL BE CONFIRMED ON SITE.
11. CONTRACTOR TO PROVIDE ACCESS PANELS IN HARD CEILINGS AS REQUIRED.
12. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
13. FOR ENLARGED PLAN CALLOUTS WE ANNOTATED CURRENT ROOM NUMBER. FLOOR PLAN
ROOM NUMBERS SHOW LEGACY ROOM NUMBERS.
THIS DRAWING WAS PRODUCED FROM ORIGINAL
AS-BUILT DRAWINGS AND FIELD OBSERVATIONS, AND
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
UP
DN
UP
DN
UP
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
UNOCCUPIED
BQ110
STAIR
UNASSIGNED
STAIRS
STAIRS
STAIRS
STAIRS
ELECT
EMERGENCY ELECT.
SUPPLIES
BQ104
EXIT PASSAGEWAY
BQ105
TEMP ELEC DSCNT
BQ114
ELEC
BQ107
ELEC
BQ108
SHAFT
SHQ02
ELEC
BQ100
EMER ELEC
BQ101
UNOCCUPIED
BQ106
CORR
BQ-C01
LOBBY
BQ103
STAIR
STAIR
STAIR
MALE SHWR
BQ112
FEMALE SHWR
BQ111
ELEV
ELEV
QP-4
ELEV
ELEV
HK
BQ138
FIRE PUMP
BQ115
SHAFT
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
09-TD-0B1
OVERALL BASEMENT TELECOMM
DEMOLITION PLAN - BLDG. 09
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 09 TELECOMM OVERALL DEMOLITION PLAN - BASEMENT
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
UP
UP
DN
UP
UP
STAIR
STAIR
STQ-2
ELEC./AV
1Q126
CONF
1Q132
CONF
1Q130
CONF
1Q135
PANTRY
1Q129
CONF
1Q137
AUDITORIUM
1Q136
MALE
1Q118
FEMALE
1Q113
SUPPLIES
1Q112
PREFUNCTION SPACE
1Q134
MANAGER
1Q105
SUPERVISOR
1Q108A
LOAN OFFICER
1Q108B
VAULT
1Q109
ATM
1Q127
LOBBY
1Q108
OFFICE
1Q115
CLASSRM
1Q116
RECEPT
1Q114A
SEATING
1Q114B
COMPUTERS
1Q114F
AV
1Q114E
CLASSROOM
1Q104
SIM LAB
1Q100
CLASSROOM
1Q102
SERVICE WINDOW
1Q110
PERIODICALS
1Q114C
ADMIN.
1Q114D
SUPPLIES
1Q119
TR
1Q140
ELEC
1Q111
EMER ELEC
1Q111A
TELECOM
DEMARCATION
1Q103
IT CLASSRM
1Q121
IT CLASSRM
1Q122
ASST./ WAITING
1Q123A
ACOS
1Q123B
IT SUPPLIES
1Q120
CAFE
1Q125
STAIR
STQ-4
STAIR
STQ-3
PREFUNCTION SPACE
1Q138
WRKSTN
1Q107
HK
1Q131
CHILLED WATER PUMP
1Q117
CHAIRS
1Q144
MALE
1Q133
FEMALE
1Q128
ELEC
16CORR
1Q-C01
LOBBY
1Q139
ELEV
QP-1 ELEV
QP-2
SHAFT
SHQ01
SHAFT
SHQ03
LIBRARY
1Q114
SHAFT
SHQ04
SHAFT
SHQ09
CORR
1Q-C06
CORR
1Q-C04
CORR
1Q-C03
ELEV
SUPPLIES
1Q106
CAFE WRKRM
1Q141
LVSR
1Q101
ELEV LOBBY
1Q139A
PREFUNCTION SPACE
1Q146
PREFUNCTION SPACE
1Q145
TELEPHONE EQUIP
1Q124
SHAFT
SHQ10
SHAFT
ELEC
SHQ12
09-TD-011
09-TD-011
(E)CABLE TRAY
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
TR
1Q140
(E)SBB
(E)1Q129A-RK1
(E)1Q129A-RK2
(E)1Q129A-RK3
(E)1Q129A-RK4
(E)1Q122-RK1
(E)SBB
(E)1Q122-RK2
(E)1Q122-RK3
TELEPHONE EQUIP
1Q124
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
09-TD-011
OVERALL FIRST FLOOR TELECOMM
DEMOLITION PLAN - BLDG. 09
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 09 TELECOMM OVERALL DEMOLITION PLAN - LEVEL 1
DEMOLITION GENERAL NOTES
1 VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2 DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
3 COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
4 CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
5 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
6 CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD" OR ANY PORTS
WITHOUT AN ADDRESS IN EXISTING PATCH PANELS AND VERIFY AN OUTLET. FOR PRICING
PURPOSES ASSUME A MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
7 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
PLAN NOTES
1 EXISTING COMMUNICATIONS 2-POST RACK TO REMAIN.
1/4" = 1'-0"2
ENLARGED TELECOMM DEMO PLAN - TR 1Q129A
1/4" = 1'-0"3
ENLARGED TELECOMM DEMO PLAN - TR 1Q122
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
DN
UP UPDN
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
STAIR
STQ-1
MALE
2Q113
STAIR
WFD INSTR (6)
2Q138
VIDEO EDT
2Q127
CONFERENCE
2Q122
CONF
2Q118
SECTRY/RECEP
2Q117
ILLSTN PREP
2Q103
DEPUTY PAO
2Q104
PA OFFICER
2Q100
FEMALE
2Q111
TR
2Q112A
ELEC
2Q105
EMER ELEC
2Q107
CLERICAL (2)
2Q108
LOUNGE
2Q106
WKRM
2Q128
CHIEF
2Q115
CENTRAL COPY CNTR
2Q101
WFD COORD
2Q136
ILL WKRM (2)
2Q103A
PHOTO/VIDEO STUDIO
2Q131
AV STOR/ CHECK OUT
2Q121
TECH WKRM
2Q123
MMS/MMEC SUPPLIES
2Q129
VIDEO CONF
VIDEO CONF
2Q116
PHOTO/ DIGITAL EDIT/
2Q109
DEPUTY PAO
2Q102
SECTRY/ WAITING
2Q110
MOVE WELL COORD
2Q132DLO
2Q126
WELL ADMIN
2Q134
CHANGING
2Q119
HK
2Q114
PAPER
2Q133
ELEC
SAFE PAT HANDL
2Q130
LOBBY
2Q124
ELEV
ELEV
QP-3
ELEV
SHAFT
SHAFT
CORR
2Q-C02
CORR
2Q-C03
CORR
2Q-C01
CORR
2Q-C04 RECYCLE
2Q135
LVSR
2Q112
SHAFT
SHQ11
SHAFT
SHAFT
09-TD-021
(E)CABLE TRAY
(E)CABLE TRAY
TR
2Q112A
(E)SBB
(E)2Q133A-RK3
(E)2Q133A-RK2
(E)2Q133A-RK1
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
09-TD-021
OVERALL SECOND FLOOR TELECOMM
DEMOLITION PLAN - BLDG. 09
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 09 TELECOMM OVERALL DEMOLITION PLAN - LEVEL 2
DEMOLITION GENERAL NOTES
1 VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2 DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
3 COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
4 CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
5 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
6 CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD" OR ANY PORTS
WITHOUT AN ADDRESS IN EXISTING PATCH PANELS AND VERIFY AN OUTLET. FOR PRICING
PURPOSES ASSUME A MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
7 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
PLAN NOTES
1 EXISTING COMMUNICATIONS 2-POST RACK TO REMAIN.
1/4" = 1'-0"2
ENLARGED TELECOMM DEMO PLAN - TR 2Q133A
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
DNUP DN UPUP
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
STAIR
RCRD FILE
3Q110
FEMALE
3Q105
MALE
3Q107
CLEAN
3Q101C
NURSE
3Q101K PRSNL MGMT
3Q121
LOUNGE
3Q114WKRM
3Q106
PRSNL MGMT
3Q124
PRSNL MGMT
3Q119
EXAM1
3Q101H
EAP
3Q103
RECEP WAITING
3Q128
PRSNL MGMT
3Q146
SPRVSR
3Q102
NURSE
3Q101A
PRSNL MGMT
3Q142
PRSNL MGMT
3Q104
TR
3Q118A
ELEC
3Q101F
EMER ELEC
3Q101E
CHIEF
3Q138
PRSNL MGMT
3Q129
PRSNL MGMT
3Q116
PRSNL MGMT
3Q112
SPRVSR
3Q100 PRSNL MGMT
3Q108
PRSNL MGMT
3Q123
PRSNL MGMT
3Q131
PRSNL MGMT
3Q144
CONF
3Q126PRSNL MGMT
3Q122
FNGRPRNT MACH
3Q132
PRSNL MGMT
3Q127
ASST CHIEF
3Q134
SCTRY
3Q136
EXAM2
3Q101J
SOILED UTILITY
3Q101B
T
3Q101D
CLERK/WAITING
3Q101G
PERSONNEL ASSTS.
3Q140
WORKSTATIONS
HK
3Q120
RECPT
3Q111
CONF
3Q113
UNION PRES
3Q109
RECPT
3Q115
UNION PRES
3Q117
EMER ELEC
3Q125
ELEC
CORR
3Q-C01A
LOBBY
3Q130
CORR
3Q-C01
EMPLY HEALTH
3Q101
CORR
3Q-C02
CORR
3Q-C02A
ELEV
ELEV
ELEV
STAIR
SHAFT
SHAFT
HR CARRELS
3Q128A
FILES
3Q101L
LVSR
3Q118
SHAFT
SHAFT
SHAFT
09-TD-031
(E)CABLE TRAY
(E)SBB
(E)3Q134A-RK3
(E)3Q134A-RK2
(E)3Q134A-RK1
TR
3Q118A
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
09-TD-031
OVERALL THIRD FLOOR TELECOMM
DEMOLITION PLAN - BLDG. 09
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 09 TELECOMM OVERALL DEMOLITION PLAN - LEVEL 3
DEMOLITION GENERAL NOTES
1 VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2 DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
3 COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
4 CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
5 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
6 CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD" OR ANY PORTS
WITHOUT AN ADDRESS IN EXISTING PATCH PANELS AND VERIFY AN OUTLET. FOR PRICING
PURPOSES ASSUME A MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
7 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
PLAN NOTES
1 EXISTING COMMUNICATIONS 2-POST RACK TO REMAIN.
1/4" = 1'-0"2
ENLARGED TELECOMM DEMO PLAN - TR 3Q134A
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
UP DN UPDNDN
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
STAIR
3MALE
4Q113
FEMALE
4Q111
CONF
4Q121
ELEC
4Q107
TR
4Q112A
EMER ELEC
4Q105
WKRM
4Q101B
CNSLR
4Q101G
CNSLR
4Q101H
CONF
4Q103
CNSLR
4Q101J
INFCT CONTROL MNGRS
(2)
4Q100
QM ADMIN
4Q104
ACOS QM
4Q106 RSK MNGR
4Q118
ASST QM
4Q102
PSA
4Q110 RECEPTION
4Q126
INFMTC MNGR
4Q144
PTNT SAFETY
4Q138
ANALYST
4Q140
ACRDTN COORD
4Q124
CNSLR
4Q101F
WKRM
4Q132
BREAK
4Q108
CRDNTL MNGR
4Q130B
CRDNTL
4Q130
SWITCH GEAR
4Q131
ANALYST
4Q116
ANALYST
4Q122WKRM
4Q120
FILES
4Q136
STAIR
HK
4Q114
EEO SCTRY/ WAITING
4Q119
EEO OFFICE
4Q117
EEO HEARING ROOM
4Q109
CLNL CORD (4)
4Q142
SUPPLIES
4Q101D
PRLGL
4Q101A
CNSLR
4Q101C
RECEPTION
4Q101E
ELEC
COUNCIL
4Q101
CORR
4Q-C04
CORR
4Q-C03
LOBBY
4Q128
CORR
4Q-C02
CORR
4Q-C01
ELEV
ELEV
ELEV
39 SHAFT
SHAFT
SUPPLIES
4Q137
PTNT SAFETY
4Q134
CRDNTL CARRELS
4Q130A
SFTY CHIEF
4Q139
TECH
4Q133
TECH
4Q129
TECH
4Q127
TECH
4Q125
LIBRARY/STRG
4Q123 SCRTY
4Q135
OFFICE
4Q141
LVSR
4Q112
SHAFT
SHAFT
SHAFT
09-TD-041
(E)CABLE TRAY
TR
4Q112A
(E)SBB
(E)4Q136A-RK3
(E)4Q136A-RK2
(E)4Q136A-RK1
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
09-TD-041
OVERALL FOURTH FLOOR TELECOMM
DEMOLITION PLAN - BLDG. 09
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 09 TELECOMM OVERALL DEMOLITION PLAN - LEVEL 4
DEMOLITION GENERAL NOTES
1 VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2 DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
3 COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
4 CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
5 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
6 CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD" OR ANY PORTS
WITHOUT AN ADDRESS IN EXISTING PATCH PANELS AND VERIFY AN OUTLET. FOR PRICING
PURPOSES ASSUME A MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
7 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
PLAN NOTES
1 EXISTING COMMUNICATIONS 2-POST RACK TO REMAIN.
1/4" = 1'-0"2
ENLARGED TELECOMM DEMO PLAN - TR 4Q136A
MAY NOT REPRESENT AN ACCURATE AS-BUILT
CONDITION. DISCREPANCIES MAY BE ENCOUNTERED,
AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
FIELD VERIFY ALL CONDITIONS.
DN DN UPUP
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
STAIR
TR
5Q104A
MALE
5Q117
FEMALE
5Q115
ELEC
5Q109
STAIR
EMER ELEC
5Q107
HK
5Q106
SUPPLIES
5Q100A
NE ANALYST
5Q138
ITAC
5Q140
ASST CHIEF
5Q144
SCTRY
5Q116
FCLTY PLNR
5Q110
CONF/ CLASSROOM
5Q100
RECEPTION
5Q123
EMRGY PRPDNS
5Q113
DIRECTOR
5Q132
DEPUTY COS
5Q125
SCTRY
5Q137 ASSOC DRCTR
5Q141
COS ADMIN
5Q127
T
5Q132A
DRCTR ADMIN
5Q128
SCTRY
5Q130
NS ADMIN
5Q124NRS SRV
5Q122
PSA
5Q119
SYST RDSN
5Q102 TRAINEES (3)
5Q126
BSNS CNTR
5Q105
ASST DRCTR
5Q114
COS
5Q129
ASSOC ADMIN
5Q143
PSA
5Q139
PSA
5Q135
CONF
5Q136
ASST ADMIN
5Q112
CSTMR SERV
5Q121
PSA
5Q108
COPY
5Q134
CONF
5Q101
SCTRY
5Q142
SCTRY
5Q133
SCTRY
5Q118
SRVG
5Q100B
SHAFT
ELEV
ELEV
ELEV
LOBBY
5Q120
CORR
5Q-C04
CORR
5Q-C01
CORR
5Q-C03
CORR
5Q-C02
SHAFT
CORR
5Q-C03A
BREAK
5Q103
OFFICE
5Q111
FILE/VAULT
5Q145
LVSR
5Q104
SHAFT
SHAFT
09-TD-051
(E)CABLE TRAY
TR
5Q104A
(E)SBB
(E)5Q137A-RK3
(E)5Q137A-RK2
(E)5Q137A-RK1
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
09-TD-051
OVERALL FIFTH FLOOR TELECOMM
DEMOLITION PLAN - BLDG. 09
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 09 TELECOMM OVERALL DEMOLITION PLAN - LEVEL 5
DEMOLITION GENERAL NOTES
1 VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE
CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION.
2 DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO OTHERWISE BY OWNER.
3 COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL.
4 CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
5 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
6 CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD" OR ANY PORTS
WITHOUT AN ADDRESS IN EXISTING PATCH PANELS AND VERIFY AN OUTLET. FOR PRICING
PURPOSES ASSUME A MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
7 IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ONSITE.
PLAN NOTES
1 EXISTING COMMUNICATIONS 2-POST RACK TO REMAIN.
1/4" = 1'-0"2
ENLARGED TELECOMM DEMO PLAN - TR 5Q137A
UP
DN
UP
NORTH
KEY PLAN
KEY PLAN
Q B
C
D
E
F
G
J
H
K
L M
P
N
S H
O T
G U
N
F
IS
H E
R
UNOCCUPIED
BQ110
STAIR
UNASSIGNED
STAIRS
STAIRS
STAIRS
STAIRS
SUPPLIES
BQ104
EXIT PASSAGEWAY
BQ105
TEMP ELEC DSCNT
BQ114
ELEC
BQ107
ELEC
BQ108
SHAFT
SHQ02
ELEC
BQ100
EMER ELEC
BQ101
UNOCCUPIED
BQ106
CORR
BQ-C01
LOBBY
BQ103
STAIR
STAIR
STAIR
MALE SHWR
BQ112
FEMALE SHWR
BQ111
ELEV
ELEV
QP-4
ELEV
ELEV
HK
BQ138
FIRE PUMP
BQ115
SHAFT
SEE SHEET 00-TS-001
FOR CONTINUATION
(7)24-STR SM (OS2)
4"C.
(7)24-STR SM (OS2)
4"C. UP TO 1ST FLR
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD
321 4 5 6 7 8 9 10
STAMP
LOCATION
''1
CONSULTANTS
FOR OFFICIAL USE ONLY (FOUO)
04-25-2023
FULLY
SPRINKLED
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
Kramer Gehlen & Associates Structural Engineers 400 Columbia St., Suite 240, Vancouver, WA 98660 Vancouver
10% BASIS OF DESIGN 07.08.2022
35% SCHEMATIC DESIGN 11.10.2022
65% DESIGN DEVELOPMENT 01.13.2023
95% CONSTRUCTION DOCUMENTS 03.17.2023 GDM of Oregon
1000 W. STEUBEN ST., UNIT 3
BINGEN, WA 98605
P: 541.436.4723
ADAM GODDIN, PE
WWW.GDM-AE.COM
TERP consulting Fire + Life Safety
14241 E. 4th Avenue, Suite 5-230 Aurora CO, 80011
FINAL BID DOCUMENTS 04.25.2023
A u to d e s k D o c s /2
-0
N e w O rl e a n s
E H
R M
/2 -0
N
O L
A E
H R
M
C O
N C
O U
R S
E
E le c I n t-
R
.r v t
09-TN-0B1
OVERALL BASEMENT TELECOMM PLAN -
BLDG. 09
DJC AH
VA NEW ORLEANS (EHRM) ELECTRONIC
HEALTH RECORD MODERNIZATION
INFRASTRUCTURE UPGRADES
2400 CANAL STREET, NEW ORLEANS, LA 70119
FINAL BID DOCUMENTS 629-22-700
1/8" = 1'-0"1
BLDG. 09 TELECOMM OVERALL PLAN - BASEMENT
GENERAL NOTES
1. CONTRACTOR TO PROVIDE ALL CONDUIT SLEEVES AND CONDUIT. CONDUIT SLEEVES TO BE
SIZED AS REQUIRED FOR ROUTING OF TELECOMMUNICATIONS CABLING THROUGH WALLS
AND NON ACCESSIBLE CEILING AREAS. CONDUIT SLEEVES SHALL BE HILTI SPEED SLEEVES.
CONDUIT SIZE IS TO BE AS NOTED.
2. FOR NEW CONDUIT INSTALLATIONS THAT PENETRATE THROUGH EXISTING CONCRETE
WALLS AND FLOORS, CONTRACTOR SHALL PROVIDE ALL CORE-DRILLING, SEALING, AND
FIRE STOPPING AS REQUIRED.
3. ALL NEW FIBER SHALL BE REROUTED IN NEW INNERDUCT. INNERDUCT SHALL BE UTILIZED
FOR ROUTING FROM POINT OF ENTRY TO TERMINATION RACK AND SHALL UTILIZE NEW AND
EXISTING PATHWAYS AS REQUIRED.
4. ALL FIBER OPTIC CABLES ARE TO BE FIELD TERMINATED ON BOTH ENDS WITH SPLICE
CASSETTE CONNECTORS. ALL LENGTHS LISTED IN MATRIX ON SHEET 000-TG-001, ARE
APPROXIMATE. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO VERIFY REQUIRED
LENGTHS PRIOR TO PURCHASE OF FACTOR TERMINATED CABLES. CONTRACTOR SHALL
PROVIDE 10' OF ADDITIONAL LENGTH AT EACH END AND 16' WITHIN EACH VAULT FOR
SERVICE LOOPS.
5. TERMINATE FIBER CABLING IN NEW FIBER PATCH PANELS IN TELECOMMUNICATION RACKS.
6. CONTRACTOR TO PROVIDE NEW J-HOOKS SIZED AS REQUIRED FOR ROUTING OF FIBER
OPTIC CABLE IN ACCESSIBLE SPACES AS SHOWN. PROVIDE ALL APPURTENANCES FOR
INSTALLATION OF J-HOOKS.
7. IN GENERAL, DROP LOCATIONS ARE PROVIDED FOR GUIDANCE ONLY. CONTRACTOR IS
RESPONSIBLE TO CONFIRM ALL OUTLET LOCATIONS ON SITE.
8. PROVIDE 3/4" AC GRADE(OR BETER) PLYWOOD ON ALL WALLS IN TR ROOMS. PLYWOOD WILL
BE FIRE RETARDANT AND COATED WITH TWO COATS OF FIRE RETARDANT PAINT. THE
BOTTOM OF THE PLYWOOD SHOULD BE MOUNTED 6" AFF.
9. CONTRACTOR SHALL TRACE ALL PORTS LABELED "BLANK", "OPEN", "BAD", OR ANY PORTS
WITHOUT AN ADDRESS, AND VERIFY AN OUTLET. FOR PRICING PURPOSES, ASSUME A
MINIMUM OF 200FT OF CABLING TO EACH OUTLET.
10. DRAWING PLANS INDICATE NUMBER OF DROPS IN AREAS THAT ARE SERVED EXACT
LOCATION OF DROPS IN EACH AREA SHALL BE CONFIRMED ON SITE.
11. CONTRACTOR TO PROVIDE ACCESS PANELS IN HARD CEILINGS AS REQUIRED.
12. CONTRACTOR SHALL BE RESPONSIBLE TO TEMPORARILY MOVE AND RETURN FURNITURE,
FIXTURES, AND EQUIPMENT WITHIN SPACES AS REQUIRED TO COMPLETE EACH DAY'S
WORK. THE VA WILL REMOVE, OR SECURE, PHI, PPI, AND PERSONAL PROPERTY.
COORDINATE THIS WORK WITH THE COR.
13.