This file is a comprehensive set of electrical construction drawings for the USCG Offshore Patrol Cutters (OPC) Homeport Pier at Naval Station Newport, Newport, Rhode Island. The drawings cover the complete electrical infrastructure required for the pier facility, including power distribution, communications, lighting, grounding, and cathodic protection systems. The project involves two electrical substations (P1W and P1E) with 30 KVA transformers each, multiple power mounds providing 480V shore power receptacles and industrial power connections, and comprehensive cabling and ductbank systems throughout the pier. Key electrical components specified include unit substations with 3000A, 450V ratings, 15KV switchgear structures, SF6 insulated pad-mounted switches, line insulation monitoring systems, and advanced metering infrastructure (AMI) for power monitoring.

The electrical systems are designed to support multiple vessel tie-in capabilities with safety interlocks, heat trace systems for freeze protection on exposed piping, dual high-mast lighting poles with LED fixtures, and integrated communications networks utilizing fiber optic cables and CAT6 copper cabling. The design includes comprehensive grounding and lightning protection systems with bare copper conductors embedded in concrete, cathodic protection for steel piles using high-potential aluminum anodes, and multiple electrical manholes positioned throughout the site. The contract specifications reference compliance with the USCG Electrical Shore Ties CSTO standard, National Electrical Code, and IEEE standards. The drawings indicate a project cost reference of approximately $247 million and include provisions for phased commissioning, testing, and coordination with existing Naval Station infrastructure and Substation 1 power distribution systems.

View the file

Other files

File Type Posted
2026-0816-HAI-USCG Homeport OPC Pier-Geotech Engineering Report Rev 2.pdf PDF
Amendment 0008 USCG OPC.pdf PDF
Updated Attachment H - USCG OPC Pier Price Proposal Form REV 6.docx DOCX document
Updated Attachment H - USCG OPC Pier Price Proposal Form REV 5.docx DOCX document
Amendment 0006 USCG OPC.pdf PDF
Attachment Z - Pier 1 - Amendment 006 Drawings.pdf PDF
Updated Attachment H - UCCG OPC Pier Price Proposal Form REV 4.docx DOCX document
Updated Attachment H - UCCG OPC Pier Price Proposal Form REV 3.docx DOCX document
24.168 NOAA OMAO Bulkhead Pile Driving Summary Table 07.31.24 to 08.01.24.pdf PDF
24.168 NOAA OMAO Bulkhead Pile Driving Summary Table 06.25.24 to 06.27.24.pdf PDF
SUB-0284 PDA49B_A.pdf PDF
SUB-0262 Interim PDA Test Pile Logs for Pier Piles - Bent 35 B - A.pdf PDF
24.107 NOAA OMAO Ship & Support Facility Relocation Newport RI - PDA Report - Pier Bent 19.pdf PDF
24.107 NOAA OMAO Ship Support Facility Relocation Newport RI - PDA Report - Pier Bent 25 and 27.pdf PDF
Amendment 0005 USCG OPC.pdf PDF
Attachment W - Pier 1 - Amendment 005 Drawings.pdf PDF
Attachment Y - Appendix A Record drawing 11836 125 Submarine Cable Relocation.pdf PDF
24.168 NOAA OMAO Bulkhead Pile Driving Summary Table 08.07.24 to 08.08.24.pdf PDF
24.168 NOAA OMAO Bulkhead Pile Driving Summary Table 08.20.24 to 08.23.24 (1).pdf PDF
Bulkhead Pile Plan.pdf PDF
24.168 NOAA OMAO Bulkhead Pile Driving Summary Table 08.20.24 to 08.23.24.pdf PDF
24.168 NOAA OMAO Bulkhead Pile Driving Summary Table 09.03.24 to 09.06.24.pdf PDF
NOAA OMAO Survey Reports 100 Percent Pre-Final Submittal 04072022.pdf PDF
SUB-0105 Trestle Piles 4C 6B - PDA and Test Pile Logs.pdf PDF
Trestle Summary.pdf PDF
SUB-0TBD Interim PDA and Test Pile Logs For Trestle Pile 17B.pdf PDF
Attachment V - Pier 1 - Amendment 004 Drawings.pdf PDF
Attachment C - Construction Experience Project Data Sheet.docx DOCX document
Attachment D - Past Performance Questionnaire.docx DOCX document
Updated Attachment F - SB Participation Commitment Document.docx DOCX document
Attachment S - Pier 1 - Amendment 003 Drawings.pdf PDF
CJA ML-23-80 - Redacted.pdf PDF
JA ML-26-40 USCG Kaeser Compressed Air System - Redacted.pdf PDF
JA ML-26-43 USCG Sanitary Pumps - Redacted.pdf PDF
Updated Attachment H - UCCG OPC Pier Price Proposal Form REV 2.docx DOCX document
Attachment Q - Spc 100 Final Specs Appendix D - (With Placeholders).pdf PDF
Amendment 0002 USCG OPC.pdf PDF
Updated Attachment H - UCCG OPC Pier Price Proposal Form REV 1.pdf PDF
Attachment M - 01 45 35_Schedule_of_Special_Inspections.pdf PDF
Attachment N - 01 45 35_Statement_of_Special_Inspections.xlsx XLSX spreadsheet
Attachment L - Site Visit Log.pdf PDF
Updated Attachment F - SB Participation Commitment Document.pdf PDF
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment I - SECNAV FORM 5512.pdf PDF
1826479dwg04of05_MECH.pdf PDF
Solicitation - N4008526R0001.pdf PDF
Attachment D - Past Performance Questionnaire.pdf PDF
Attachment H - UCCG OPC Pier Price Proposal Form.pdf PDF
1826479dwg01of05_GEN-CIV.pdf PDF
Attachment E - Historical Small Business Utilization.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Approved by Frank Cole USCG MASI

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L K

V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:3 :1

P

M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In it ia ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1 -S

.r v t

G-002

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

IN

D

E X

O F

D R

A W

IN

G

S

S H

E E

T

O F

MN

12936571

CHG HBF

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T, R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

NEK

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

G -0

GENERAL SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

1 G-001 12936570 TITLE SHEET

2 G-002 12936571 INDEX OF DRAWINGS - SHEET 1 OF 2

3 G-003 12936572 INDEX OF DRAWINGS - SHEET 2 OF 2

4 G-004 12936573 GENERAL ABBREVIATIONS

5 G-101 12936574 OVERVIEW EXISTING SITE CONTROLS

6 G-102 12936575 GENERAL SITE PLAN

7 G-103 12936576 GENERAL ARRANGEMENT PLAN

8 G-104 12936577 GENERAL ARRANGEMENT SECTION

9 G-105 12936578 CONTRACTOR ACCESS ROUTE PLAN

10 G-106 12936579 MOORING ARRANGEMENT PLAN

11 G-107 12936580 BATHYMETRIC SURVEY PLAN

LIST OF SHEETS

GEOTECHNICAL SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

23 B-101 12936592 ESTIMATED TOP OF WEATHERED ROCK CONTOUR PLAN

24 B-601 12936593 SOIL BORING LOGS - SHEET 1 OF 6

25 B-602 12936594 SOIL BORING LOGS - SHEET 2 OF 6

26 B-603 12936595 SOIL BORING LOGS - SHEET 3 OF 6

27 B-604 12936596 SOIL BORING LOGS - SHEET 4 OF 6

28 B-605 12936597 SOIL BORING LOGS - SHEET 5 OF 6

29 B-606 12936598 SOIL BORING LOGS - SHEET 6 OF 6

STRUCTURAL SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

50 S-001 12936619 STRUCTURAL ABBREVIATION (BASE BID)

51 S-002 12936620 STRUCTURAL GENERAL NOTES - SHEET 1 OF 2 (BASE BID)

52 S-003 12936621 STRUCTURAL GENERAL NOTES - SHEET 2 OF 2 (BASE BID)

53 S-004 12936622 STRUCTURAL DESIGN LOADS AND STANDARD DETAILS - SHEET 1 OF 2

54 S-005 12936623 STRUCTURAL DESIGN LOADS AND STANDARD DETAILS - SHEET 2 OF 2

55 SD001 12936624 STRUCTURAL DEMOLITION NOTES (BASE BID)

56 SD101 12936625 OVERALL STRUCTURAL DEMOLITION PLAN (BASE BID)

57 SD102 12936626 PIER 1 DEMOLITION PLAN

58 SD103 12936627 S45N BULKHEAD DEMOLITION PLAN

59 SD104 12936628 S45S BULKHEAD DEMOLITION PLAN (BASE BID)

60 SD201 12936629 S45N BULKHEAD DEMOLITION ELEVATION

61 SD202 12936630 TEMPORARY SHEETING BULKHEAD ELEVATION

62 SD301 12936631 TYPICAL SECTION FOR PIER 1 DEMOLITION (BASE BID)

63 SD302 12936632 TYPICAL SECTION FOR BULKHEAD DEMOLITION

64 SD303 12936633 SECTION OF DEMOLITION AT S45N BULKHEAD (BASE BID)

65 SD501 12936634 MISCELLANEOUS DEMOLITION DETAILS

66 SD601 12936635 PIER 1 AND S45N BULKHEAD DEMOLITION PHOTOGRAPHS (BASE BID)

67 SD602 12936636 S45N BULKHEAD DEMOLITION PHOTOGRAPHS (BASE BID)

68 S-101 12936637 OVERALL BULKHEAD PLAN (BASE BID)

69 S-102 12936638 GENERAL DECK PLAN

70 S-103 12936639 PILE PLAN - SHEET 1 OF 7

71 S-104 12936640 PILE PLAN - SHEET 2 OF 7

72 S-105 12936641 PILE PLAN - SHEET 3 OF 7

73 S-106 12936642 PILE PLAN - SHEET 4 OF 7

74 S-107 12936643 PILE PLAN - SHEET 5 OF 7

75 S-108 12936644 PILE PLAN - SHEET 6 OF 7

76 S-109 12936645 PILE PLAN - SHEET 7 OF 7

77 S-110 12936646 FRAMING PLAN - SHEET 1 OF 7

78 S-111 12936647 FRAMING PLAN - SHEET 2 OF 7

79 S-112 12936648 FRAMING PLAN - SHEET 3 OF 7

80 S-113 12936649 FRAMING PLAN - SHEET 4 OF 7

81 S-114 12936650 FRAMING PLAN - SHEET 5 OF 7

82 S-115 12936651 FRAMING PLAN - SHEET 6 OF 7

83 S-116 12936652 FRAMING PLAN - SHEET 7 OF 7

84 S-117 12936653 CONCRETE PLANKS PLAN - SHEET 1 OF 7

85 S-118 12936654 CONCRETE PLANKS PLAN - SHEET 2 OF 7

86 S-119 12936655 CONCRETE PLANKS PLAN - SHEET 3 OF 7

87 S-120 12936656 CONCRETE PLANKS PLAN - SHEET 4 OF 7

88 S-121 12936657 CONCRETE PLANKS PLAN - SHEET 5 OF 7

89 S-122 12936658 CONCRETE PLANKS PLAN - SHEET 6 OF 7

90 S-123 12936659 CONCRETE PLANKS PLAN - SHEET 7 OF 7

91 S-124 12936660 DECK PLAN - SHEET 1 OF 7

92 S-125 12936661 DECK PLAN - SHEET 2 OF 7

93 S-126 12936662 DECK PLAN - SHEET 3 OF 7

94 S-127 12936663 DECK PLAN - SHEET 4 OF 7

95 S-128 12936664 DECK PLAN - SHEET 5 OF 7

96 S-129 12936665 DECK PLAN - SHEET 6 OF 7

97 S-130 12936666 DECK PLAN - SHEET 7 OF 7

98 S-131 12936667 FENDER PILE PLAN - SHEET 1 OF 6

99 S-132 12936668 FENDER PILE PLAN - SHEET 2 OF 6

STRUCTURAL SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

100 S-133 12936669 FENDER PILE PLAN - SHEET 3 OF 6

101 S-134 12936670 FENDER PILE PLAN - SHEET 4 OF 6

102 S-135 12936671 FENDER PILE PLAN - SHEET 5 OF 6

103 S-136 12936672 FENDER PILE PLAN - SHEET 6 OF 6

104 S-137 12936673 DECK DRAINAGE PLAN - SHEET 1 OF 2

105 S-138 12936674 DECK DRAINAGE PLAN - SHEET 2 OF 2

106 S-201 12936675 PIER SOUTHERN ELEVATION - SHEET 1 OF 3

107 S-202 12936676 PIER SOUTHERN ELEVATION - SHEET 2 OF 3

108 S-203 12936677 PIER SOUTHERN ELEVATION - SHEET 3 OF 3

109 S-204 12936678 PIER NORTHERN ELEVATION - SHEET 1 OF 3

110 S-205 12936679 PIER NORTHERN ELEVATION - SHEET 2 OF 3

111 S-206 12936680 PIER NORTHERN ELEVATION - SHEET 3 OF 3

112 S-207 12936681 REPAIRED S45N BULKHEAD ELEVATION & PIER 1 SECTION

113 S-208 12936682 S45S BULKHEAD ELEVATION (BASE BID)

114 S-301 12936683 PIER LONGITUDINAL SECTIONS - SHEET 1 OF 2

115 S-302 12936684 PIER LONGITUDINAL SECTIONS - SHEET 2 OF 2

116 S-303 12936685 PIER ABUTMENT & APPROACH SLAB LONGITUDINAL SECTION

117 S-304 12936686 LONGITUDINAL SECTIONS AT UTILITY TRENCH

118 S-305 12936687 LONGITUDINAL SECTION CROSS UTILITY TRENCH AT ABUTMENT

119 S-306 12936688 PIER ABUTMENT & UTILITY TRENCH TRANSVERSE SECTION

120 S-307 12936689 PIER TRANSVERSE SECTIONS - SHEET 1 OF 5

121 S-308 12936690 PIER TRANSVERSE SECTIONS - SHEET 2 OF 5

122 S-309 12936691 PIER TRANSVERSE SECTIONS - SHEET 3 OF 5

123 S-310 12936692 PIER TRANSVERSE SECTIONS - SHEET 4 OF 5

124 S-311 12936693 PIER TRANSVERSE SECTIONS - SHEET 5 OF 5

125 S-401 12936694 ABUTMENT & LANDSIDE FRAMING PART PLAN

126 S-402 12936699 OUTBOARD SUBSTATION PART PLAN

127 S-403 12936700 INBOARD SUBSTATION PART PLAN

128 S-404 12936697 S45S BULKHEAD PART PLAN & SECTION (BASE BID)

129 S-501 12936698 TURBIDITY CURTAIN NOTES & DETAILS (BASE BID)

130 S-502 12936699 PILE DETAILS - CONCRETE-FILLED STEEL PIPE PILES

131 S-503 12936704 PILE DETAILS - STEEL PILES

132 S-504 12936701 CONCRETE PILE CAP DETAILS - SHEET 1 OF 3

133 S-505 12936706 CONCRETE PILE CAP DETAILS - SHEET 2 OF 3

134 S-506 12936703 CONCRETE PILE CAP DETAILS - SHEET 3 OF 3

135 S-507 12936708 REINFORCED BOLLARD FOUNDATION DETAILS

136 S-508 12936705 REINFORCEMENT DETAILS FOR CONCRETE BLOCKOUT AT BENT 43 - SHEET 1 OF 2

137 S-509 12936706 REINFORCEMENT DETAILS FOR CONCRETE BLOCKOUT AT BENT 43 - SHEET 2 OF 2

138 S-510 12936707 CONCRETE DUCTBANK REINFORCEMENT DETAILS

139 S-511 12936708 REINFORCEMENT DETAILS

140 S-512 12936709 CONCRETE BEAM DETAILS

141 S-513 12936710 TYPICAL PIER DUCTBANK DETAILS

142 S-514 12936711 LANDSIDE PIPE PILES CONNECTION DETAILS

143 S-515 12936712 PRECAST CONCRETE PLANK DETAILS

144 S-516 12936713 CONDUITS AND FITTINGS AT EXPANSION JOINT

145 S-517 12936714 PRECAST MANHOLE DETAILS

146 S-518 12936715 UTILITY TRENCH COVER DETAILS

147 S-519 12936716 FENDER SYSTEM DETAILS - SHEET 1 OF 2

148 S-520 12936717 FENDER SYSTEM DETAILS - SHEET 2 OF 2

149 S-521 12936718 PIPE SUPPORT DETAILS

150 S-522 12936719 MISCELLANEOUS SECTIONS & DETAILS - SHEET 1 OF 2

151 S-523 12936720 MISCELLANEOUS SECTIONS & DETAILS - SHEET 2 OF 2

152 S-524 12936721 S45N BULKHEAD MODIFICATION DETAILS - SHEET 1 OF 2

153 S-525 12936722 S45N BULKHEAD MODIFICATION DETAILS - SHEET 2 OF 2

154 S-526 12936723 S45S BULKHEAD DETAILS - SHEET 1 OF 3 (BASE BID)

155 S-527 12936724 S45S BULKHEAD DETAILS - SHEET 2 OF 3 (BASE BID)

156 S-528 12936725 S45S BULKHEAD DETAILS - SHEET 3 OF 3 (BASE BID)

157 S-529 12936730 AIR COMPRESSOR FOUNDATION & STEEL FRAME PART PLAN

158 S-530 12936727 AIR COMPRESSOR DETAILS

159 S-531 12936728 AIR COMPRESSOR FOUNDATION DETAILS

160 S-532 12936729 AIR COMPRESSOR STAIRS ACCESS DETAILS - SHEET 1 OF 2

161 S-533 12936730 AIR COMPRESSOR STAIRS ACCESS DETAILS - SHEET 2 OF 2

162 S-534 12936731 15KV SWITCHGEAR STRUCTURE DETAILS

163 S-601 12936732 STEEL PILE SCHEDULE

164 S-602 12936733 FENDER PILE SCHEDULE - SHEET 1 OF 2

165 S-603 12936734 FENDER PILE SCHEDULE - SHEET 2 OF 2

DREDGE SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

30 CN101 12936599 OVERALL DREDGING PLAN (BASE BID)

31 CN301 12936600 DREDGING SECTIONS - SHEET 1 OF 3 (BASE BID)

32 CN302 12936601 DREDGING SECTIONS - SHEET 2 OF 3 (BASE BID)

33 CN303 12936602 DREDGING SECTIONS - SHEET 3 OF 3 (BASE BID)

HAZARDOUS MATERIALS SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

12 H-101 12936581 HAZARDOUS MATERIALS NOTES & PLAN

CIVIL SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

34 C-001 12936603 CIVIL LEGEND, ABBREVIATIONS & GENERAL NOTES (BASE BID)

35 C-002 12936604 GENERAL NOTES (BASE BID)

36 CD101 12936605 SITE DEMOLITION PLAN (BASE BID)

37 CD102 12936606 UTILITY DEMOLITION PLAN - PIER 1 LAND SIDE (BASE BID)

38 C-101 12936607 SITE PLAN (BASE BID)

39 C-102 12936608 UTILITY PLAN - PIER 1 LAND SIDE (BASE BID)

40 C-103 12936613 COMPOSITE UTILITY LAYOUT PLAN - PIER 1 LANDSIDE (BASE BID)

41 C-201 12936610 UTILITY PROFILES - SHEET 1 OF 2

42 C-202 12936611 UTILITY PROFILES - SHEET 2 OF 2 (BASE BID)

43 C-501 12936612 EROSION CONTROL NOTES & DETAILS (BASE BID)

44 C-502 12936613 SITE DETAILS - SHEET 1 OF 6 (BASE BID)

45 C-503 12936614 SITE DETAILS - SHEET 2 OF 6

46 C-504 12936615 SITE DETAILS - SHEET 3 OF 6

47 C-505 12936616 SITE DETAILS - SHEET 4 OF 6

48 C-506 12936617 SITE DETAILS - SHEET 5 OF 6

49 C-507 12936618 SITE DETAILS - SHEET 6 OF 6

SURVEY SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

13 V-001 12936582 CODDINGTON COVE EXISTING CONDITIONS OVERVIEW

14 V-101 12936583 EXISTING CONDITIONS - PIER 2 LANDSIDE

15 V-102 12936584 EXISTING CONDITIONS - PIER 1 LANDSIDE

16 V-103 12936585 EXISTING CONDITIONS - RETENTION POND

17 V-104 12936586 EXISTING CONDITIONS - NOAA BUILDING

18 V-105 12936587 EXISTING CONDITIONS - PIER 1 SHEET 1 OF 5

19 V-106 12936588 EXISTING CONDITIONS - PIER 1 SHEET 2 OF 5

20 V-107 12936589 EXISTING CONDITIONS - PIER 1 SHEET 3 OF 5

21 V-108 12936590 EXISTING CONDITIONS - PIER 1 SHEET 4 OF 5

22 V-109 12936591 EXISTING CONDITIONS - PIER 1 SHEET 5 OF 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L K

V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:3 :1

P

M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In it ia ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1 -S

.r v t

G-003

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

IN

D

E X

O F

D R

A W

IN

G

S

S H

E E

T

O F

MN

12936572

CHG HBF

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T, R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

NEK

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

G -0

ELECTRICAL SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

190 E-001 12936759 ELECTRICAL LEGEND, ABBREVIATIONS & GENERAL NOTES

191 E-101 12936760 ELECTRICAL DECK PLAN - SHEET 1 OF 7

192 E-102 12936761 ELECTRICAL DECK PLAN - SHEET 2 OF 7

193 E-103 12936762 ELECTRICAL DECK PLAN - SHEET 3 OF 7

194 E-104 12936763 ELECTRICAL DECK PLAN - SHEET 4 OF 7

195 E-105 12936764 ELECTRICAL DECK PLAN - SHEET 5 OF 7

196 E-106 12936765 ELECTRICAL DECK PLAN - SHEET 6 OF 7

197 E-107 12936766 ELECTRICAL DECK PLAN - SHEET 7 OF 7

198 E-108 12936767 ELECTRICAL SITE PLAN - PIER 2

199 E-109 12936768 ELECTRICAL SITE PLAN - PIER 1

200 E-110 12936769 ELECTRICAL SITE PLAN - NOAA BUILDING

201 E-111 12936770 ELECTRICAL SITE PLAN - BUILDING 76

202 E-112 12936771 CATHODIC PROTECTION PILE PLAN

203 E-113 12936772 GROUNDING PLAN - PIER WEST

204 E-114 12936773 GROUNDING PLAN - PIER EAST

205 E-115 12936774 LIGHTNING PROTECTION PLAN - PIER WEST

206 E-116 12936775 LIGHTNING PROTECTION PLAN - PIER EAST

207 E-401 12936776 SUBSTATION P1W PART PLAN & ELEVATION

208 E-402 12936777 SUBSTATION P1E PART PLAN & ELEVATION

209 E-403 12936778 SUBSTATION GROUNDING PART PLANS

210 E-404 12936779 SUBSTATION P1W VAULT PART PLAN & ELEVATION

211 E-405 12936780 SUBSTATION P1E VAULT PART PLAN & ELEVATION

212 E-501 12936781 MANHOLE & DUCTBANK DETAILS

213 E-502 12936782 15KV SWITCHGEAR STRUCTURE DETAILS

214 E-503 12936783 POWER MOUND DETAILS - SHEET 1 OF 2

215 E-504 12936784 POWER MOUND DETAILS - SHEET 2 OF 2

216 E-505 12936785 METERING SYSTEM DETAILS - SHEET 1 OF 3

217 E-506 12936786 METERING SYSTEM DETAILS - SHEET 2 OF 3

218 E-507 12936787 METERING SYSTEM DETAILS - SHEET 3 OF 3

219 E-508 12936788 LUMINAIRE SCHEDULE & DETAILS

220 E-509 12936789 HIGH MAST LIGHTING DETAILS

221 E-510 12936790 SUBSTATION P1E SWITCHGEAR ELEVATIONS

222 E-511 12936791 SUBSTATION P1W SWITCHGEAR ELEVATIONS

223 E-512 12936792 MISCELLANEOUS DETAILS - SHEET 1 OF 2

224 E-513 12936793 MISCELLANEOUS DETAILS - SHEET 2 OF 2

225 E-514 12936794 HEAT TRACE CABINET & DETAILS

226 E-601 12936795 PRIMARY & DEMOLITION ONE LINE DIAGRAM

227 E-602 12936796 PIER ONE LINE DIAGRAM - EAST

228 E-603 12936797 PIER ONE LINE DIAGRAM - WEST

229 E-604 12936798 COMMUNICATIONS ONE LINE DIAGRAM

230 E-605 12936799 MANHOLE SCHEDULE & FOLDOUT DIAGRAMS

231 E-606 12936800 MINI POWER CENTER PANEL SCHEDULES

232 E-607 12936801 SWITCHGEAR BREAKER CONTROL DIAGRAM

233 E-608 12936802 HEAT TRACE ONE LINE DIAGRAM & SCHEDULES

234 E-609 12936803 LIGHTING CONTROL DIAGRAMS

235 E-610 12936804 SUBSTATION P1E SWITCHGEAR SCHEDULE

236 E-611 12936805 SUBSTATION P1W SWITCHGEAR SCHEDULE

237 E-612 12936806 SUBSTATION P1E PANEL SCHEDULES

238 E-613 12936807 SUBSTATION P1W PANEL SCHEDULES

239 E-614 12936808 FEEDER SCHEDULE - SHEET 1 OF 2

240 E-615 12936809 FEEDER SCHEDULE - SHEET 2 OF 2

MECHANICAL SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

166 M-001 12936735 MECHANICAL LEGEND, ABBREVIATIONS & GENERAL NOTES

167 M-101 12936736 MECHANICAL PLAN - SHEET 1 OF 7

168 M-102 12936737 MECHANICAL PLAN - SHEET 2 OF 7

169 M-103 12936738 MECHANICAL PLAN - SHEET 3 OF 7

170 M-104 12936739 MECHANICAL PLAN - SHEET 4 OF 7

171 M-105 12936740 MECHANICAL PLAN - SHEET 5 OF 7

172 M-106 12936741 MECHANICAL PLAN - SHEET 6 OF 7

173 M-107 12936742 MECHANICAL PLAN - SHEET 7 OF 7

174 M-301 12936743 MECHANICAL LONGITUDINAL SECTIONS - SHEET 1 OF 2

175 M-302 12936744 MECHANICAL LONGITUDINAL SECTIONS - SHEET 2 OF 2

176 M-303 12936745 MECHANICAL TRANSVERSE SECTIONS

177 M-401 12936746 MECHANICAL COMPRESSED AIR ENCLOSURE - PART PLAN

178 M-402 12936747 REDUCED PRESSURE BACKFLOW PREVENTER DETAILS

179 M-501 12936748 NORTHERN MECHANICAL ENCLOSURE DETAILS

180 M-502 12936749 SOUTHERN MECHANICAL ENCLOSURE DETAILS

181 M-503 12936750 PIER HEATED ENCLOSURE - SANITARY AND FRESH WATER

182 M-504 12936751 PIPE SUPPORT DETAILS - SHEET 1 OF 2

183 M-505 12936752 PIPE SUPPORT DETAILS - SHEET 2 OF 2

184 M-506 12936753 MECHANICAL ENCLOSURE VFD PUMP CONTROLLER DETAILS

185 M-601 12936754 MECHANICAL PIPE SCHEDULES

186 M-701 12936755 COMPRESSED AIR SCHEMATIC (BID OPTION)

187 M-702 12936756 COMPRESSED AIR HEAT RECOVERY SCHEMATIC

188 M-703 12936757 POTABLE FRESH WATER (FW) SCHEMATIC

189 M-901 12936758 MECHANICAL UTILITIES ISOMETRIC VIEWS

ELECTRICAL SUBSTATION 1 SHEET INDEX

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

241 ES101 12936810 ELECTRICAL SITE PLAN - SUBSTATION 1

242 ES102 12936811 SUBSTATION 1 PLAN VIEW

243 ES501 12936812 BREAKER 152-11 ELEVATION VIEW

244 ES601 12936813 SUBSTATION 1 SINGLE LINE DIAGRAM

245 ES602 12936814 BREAKER 152-11 SCHEMATIC DIAGRAM

246 ES603 12936815 BREAKER 152-11 DIGITAL CONTROL DIAGRAM

247 ES604 12936816 BREAKER 152-11 COMMUNICATIONS DIAGRAM

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

KEY INTERLOCK

MAXIMUM

REF

S

WP

RD

REQ'D

TRANSFORMER

DELTA CONNECTION, 3∅, 3 W.

GROUNDED WYE CONNECTION, 3∅., 4W.

600V POWER AIR CIRCUIT BREAKER, DRAWOUT TYPE

SHIP-TO-SHORE RECEPTACLE, 450V, 500A, 3∅, 3P. MIL. SPEC MIL. C24368

EQUIPMENT RECEPTACLE

FUSE - DRAWOUT TYPE

DRY TYPE TRANSFORMER

FUSE

AMMETER, AMMETER SWITCH

DEMAND WATTHOUR METER

VOLTMETER, VOLTMETER SWITCH

CONTROL SWITCH

FUSED SAFETY SWITCH, NO. OF POLES, SIZE OF SW. AND FUSE SIZE

AS SHOWN, 480V. U.O.N. STAINLESS

STEEL ENCLOSURE,NEMA 4X. NF INDICATES

NON-FUSED

LED INDICATOR LIGHT (PUSH-TO-TEST WHERE

SHOWN) R = RED, G = GREEN

RECEPTACLE-125V., 15A SINGLE CONVENIENCE

NEMA 5-15, WEATHERPROOF.

SOLID STATE TRIP

SURGE PROTECTIVE DEVICE

LIGHTING POLE, TYPE AS SHOWN

LED LIGHTING FIXTURE

SINGLE POLE 20A, 125V. SWITCH "WP"

INDICATES WEATHERPROOF

HOMERUN TO PANELBOARD, SIZE AND NUMBER

OF CONDUCTORS AND CONDUIT AS SHOWN ON

THE PLANS. CONDUITS IN DECK MUST BE PVC

(SCH. 40). CONDUITS RUN EXPOSED (UNDER DECK)

MUST BE PVC COATED RIGID GALVANIZED STEEL.

GROUND CONDUCTOR (BCSD) UON

GROUNDING CONNECTION. EXOTHERMIC WELDING

PROCESS

GROUND ROD CONNECTION

HEAT TRACE

600V CIRCUIT BREAKER, MOLDED CASE, 3 PH. U.O.N.

POTENTIAL TRANSFORMER WITH NUMBER AND

RATIO AS INDICATED.

GROUND ROD

LIGHTNING ARRESTER

AUXILIARY CONTACTS

N0-NORMALLY OPEN

NC-NORMALLY CLOSED

CURRENT TRANSFORMER WITH NUMBER

AND RATIO AS INDICATED.

PHOTOCELL

PUSH BUTTON-MOMENTARY

EXISTING CABLE DESIGNATION (NOT USED)

DUCTBANK SECTION LOOKING IN DIRECTION

OF ARROWS

SPARE DUCT SAME SIZE AS ADJACENT DUCT

PROPOSED CABLE DESIGNATION (TYPICAL).

SEE CABLE SCHEDULE

HEAVY LINE INDICATES BOTTOM OF DUCTBANK

IMPEDANCE

TRANSFORMER

WEATHER PROOF

XFMR

Z

WP

A, AMP AMPERES

AC ALTERNATING CURRENT

AF AMPERE FRAME

AFF ABOVE FINISHED FLOOR

AIC AMPERES INTERRUPTING CAPACITY

AM

AT

AMMETER

AMPERE TRIP

AUXILIARYAUX

AWG AMERICAN WIRE GAUGE

BCHD

BCSD

BKR

BLDGS

BARE COPPER HARD DRAWN

BARE COPPER SOFT DRAWN

BREAKER

BUILDINGS

C

CAB

CKT

COMB.

COMM

CONT.

CU.

DIA.

DIST.

DN.

CONDUIT

CABINET

CIRCUIT

COMBINATION

COMMUNICATIONS

CONTINUITY

COPPER

DIAMETER

DISTRIBUTION

DOWN

DPDT

DT

DWG.

EA

ELEV

EMER

ENCL.

E.O.

EQ.

EQUIP.

EX., EXIST.

EXP.

F

FDRS

FR

FT

G, GND

GA

GND FAT

GOV'T

GRS

HD'RM

HOA

HPS

DOUBLE POLE, DOUBLE THROW

DRY TYPE

DRAWING

EACH

ELEVATION

EMERGENCY

ENCLOSURE

ELECTRICALLY OPERATED

EQUAL

EQUIPMENT

EXISTING

EXPANSION

FAHRENHEIT

FEEDERS

FRAME

FEET, FOOT

GROUND

GAUGE

GROUND FAULT

GOVERNMENT

GALVANIZED RIGID STEEL

HEADROOM

HAND OFF AUTO

HIGH PRESSURE SODIUM

HR

HT

HV

HZ

IC

ID

INST

KCMIL

KV

KVA

LG

LLF

HOUR

HEAT TRACE

HIGH VOLTAGE

HERTZ

INTERRUPTING CAPACITY

IDENTIFICATION

INSTANTANEOUS

THOUSANDS OF CIRCULAR MILLS

KILOVOLTS

KILOVOLT AMP

LONG TIME

LUMEN LOSS FACTOR

LTG

LV

MAX

MCB

MFR

MH

MHW

MIL

MIN.

MISC.

MLW

MTG.

MTL

MV

N.C.

NEC

NEMA

LIGHTING

LOW VOLTAGE

MAIN CIRCUIT BREAKER

MANUFACTURER

MANHOLE

MEAN HIGH WATER

MILITARY

MINIMUM

MISCELLANEOUS

MEAN LOW WATER

MOUNTING

MATERIAL

MEDIUM VOLTAGE

NORMALLY CLOSED

NATIONAL ELECTRICAL CODE

NEUTRAL

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NEUT.

N.O.

NO., #

NP

OC

OW

P

PC

PH, ∅

PNL

PRI.

PVC

PW

RCPT

LT LIGHT

WHD

W

VM

V

UON

UL

TYP

TVSS

TR

TEL

SYM

SWGR

SW

S.S.

STA

SPEC

SHT

SEP

SEC.

RMS

SCH

ROOT MEANS SQUARED

SCHEDULE

SECONDARY

SEPARATE

SHORT TIME

SPECIFICATION

STATION

STAINLESS STEEL

SWITCH

SWITCHGEAR

SYMMETRICAL

TELEPHONE

TRIP

TRANSIENT VOLTAGE SURGE SUPPRESSOR

TYPICAL

UNDERWRITERS LABORATORY

UNLESS OTHERWISE NOTED

VOLT

VOLTMETER

WIRE, WATTS

WATT-HOUR DEMAND METER

NORMALLY OPEN

NUMBER

NAMEPLATE

ON CENTER

OILY WASTE

POLE

PHOTOCELL

PHASE

PANEL

PRIMARY

POLYVINYL CHLORIDE

POTABLE WATER

RECEPTACLE

ROAD

REFERENCE

REQUIRED

ABBREVIATIONS

LEGEND GENERAL NOTES:

DUCTBANK

EXISTING TELEPHONE DUCTBANK

DETAIL NUMBER

DRAWING NUMBER WHERE SHOWN

HIGH MAST LIGHTING POLE

NAVIGATION LIGHT POLE

LOCKOUT RELAY86

TS TEST SWITCH

GROUND DETECTION RELAY

OCT BREAKER OVERCURRENT TRIP ALARM

ETS EMERGENCY TRIP SWITCH

TCS TRIP CONTROL SWITCH (ONE PER BREAKER)

TELEPHONE TERMINAL CABINET

KEY NOTE

CABLE DESIGNATION-SEE SCHEDULE

LUMINAIRE SYMBOL.

FEATURES TO BE PROVIDED UNDER THIS

CONTRACT SHOWN THUS

EXISTING FEATURES SHOWN THUS

DISCONNECT, REMOVE AND DISPOSE OF

EXISTING ELECTRICAL EQUIPMENT/UTILITIES AND

ASSOCIATED APPURTENANCES SHOWN ON PLAN.

COMMUNICATIONS MANHOLE

POWER MANHOLE

AMI ADVANCED METERING INFRASTRUCTURE

CASCON CASUALTY CONTROL

CT CURRENT TRANSFORMER

PT POTENTIAL TRANSFORMER

A AS

FIBER ENCLOSURE WITH FIBER PATCH PANELF

JUNCTION BOXJ

LINE INSULATION MONITORING SYSTEMLIM

METER SOCKET AND AMI METER

HMI HUMAN MACHINE INTERFACE

CURRENT TRANSFORMER

SPD

SST

WP

GR

3P 30A 30A

VSV

CS

WHD

T , K

M

J

T

PC

NO NC

480V/120V

G

1. PROVIDE NECESSARY COMPONENTS REQUIRED FOR MAKING FINAL CONNECTION OF ALL EQUIPMENT INSTALLED OR MODIFIED AS PART OF THIS CONTRACT.

2. ALARM INDICATION AND CONTROL WIRING IN JUNCTION BOXES MUST BE WIRED TO NUMBERED TERMINAL STRIPS AND IDENTIFIED AS TO START AND END OF

RUN.

3. ELECTRICAL EQUIPMENT INSTALLED AGAINST CONCRETE OR MASONRY WALLS MUST BE INSTALLED WITH A 1/4" SPACE BETWEEN THE EQUIPMENT AND THE

MOUNTING SURFACE. SPACERS MUST BE STAINLESS STEEL, PVC OR NYLON.

4. PROVIDE TEST PITS (AND COORDINATE WITH CIVIL AS REQUIRED) TO DETERMINE LOCATION OF EXISTING UTILITIES BEFORE CONSTRUCTION OF DUCTBANK.

DUCTBANK MUST COORDINATE WITH EXISTING AND OTHER PROPOSED UTILITIES. MODIFY PROFILES TO SUIT EXISTING CONDITIONS.

5. UTILITIES AND ELECTRICAL EQUIPMENT SHOWN ON PIER ACCESS ROAD WERE EXISTING AT THE TIME OF FIELD SURVEY AND MAY HAVE BEEN ALTERED BEFORE CONSTRUCTION BEGINS. CONTRACTOR MUST VERIFY INFORMATION SHOWN ON THE DRAWINGS. COORDINATE WITH THE GOVERNMENT BEFORE

REMOVAL OF SAME.

6. EXTERIOR ENCLOSURES MUST BE NEMA 3RX OR 4X RATED AND UTILIZE TYPE 316 STAINLESS STEEL HARDWARE. NEMA 3RX ENCLOSURES MUST BE

CONSTRUCTED OF TYPE 316 STAINLESS STEEL.

7. SEE USCG ELECTRICAL SHORE TIES CSTO REV B (SILC-CSTO-36 11 21 27 11-04) SECTION 2.4.6 FOR ADDITIONAL ELECTRICAL INSTALLATION AND ACCEPTANCE

TESTING REQUIREMENTS THAT ARE NOT COVERED IN THE PROJECT SPECIFICATIONS.

8. CONDUIT TYPES MUST BE:

A. LANDSIDE IN CONCRETE ENCASED DUCTBANK: PVC SCHEDULE 40

B. ON PIER IN CONCRETE ENCASED DUCTBANK: PVC SCHEDULE 80

C. EXPOSED BELOW PIER, ON PIER EXTERIOR, AND TURNING UP INTO TOPSIDE EQUIPMENT: RTRC TYPE XW.

D. EXPOSED IN SUBSTATION P1E AND P1W: RTRC TYPE XW

E. EXPOSED IN UTILITY TRENCH: RTRC TYPE XW.

P

C

H HEAT TRACE MULTIPLE ENTRY CONNECTION BOX. HT-X

DENOTES HEAD TRACE PANEL, CIRCUIT NUMBER "X"

1 2

A X

T THERMOSTAT

THERMOSTATT

ATS AUTOMATIC TRANSFER SWITCH

EMH ELECTRIC MANHOLE

AHU AIR HANDLING UNIT

HVAC HEATING VENTILATING AND AIR CONDITIONING

LIGHTNING PROTECTION AIR TERMINAL

DLO DIESEL LOCOMOTIVE CABLE

500:5

TRI-PHASE CONTROLLERTPC

PHASE LOSS RELAYPLR

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A

TL

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:1

:3

P M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In iti a ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1

-E

.r v t

E-001

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

E

LE

C

TR

IC

A

L

LE

G E

N D

, A B

B R

E V

IA

TI

O N

S

G E

N E

R A

L N

O

TE

S

RJW

12936759

DPF GLV

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T , R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

WRB

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

E -0

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

David Ferguson

T

A

B

D

E

F

383940414243

C 5419 424141

44 44 44 19 45

44 44 44 19 46

41 41 41 19 42

41 41 41 19 43

SUBSTATION P1W

9 19

E-401 C1

C PIERL

9 19 7

EMH-BC-4142

2020 20 20

67 20

7 19 8

2019 434141 2041

19 19 19 19 19 19

EMH-CD-4041

491623303743 0

KEY PLAN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A

TL

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:1

:3

P M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In iti a ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1

-E

.r v t

E-101

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

E

LE

C

TR

IC

A

L D

E C

K P

LA

N

S

H E

E T

O

F

RJW

12936760

DPF GLV

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T , R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

WRB

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

E -1

PLAN

NORTH

SCALE: 1/8" = 1'-0"

ELECTRICAL DECK PLAN - SHEET 1 OF 7

B2

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES, SEE

DRAWING E-001. FOR POWER AND COMMUNICATIONS ONE LINE

DIAGRAMS SEE DRAWINGS E-601, E-602, E-603 AND E-604. FOR FEEDER

SCHEDULE SEE DRAWINGS E-614 AND E-615.

2. PROVIDE EXPANSION/DEFLECTION FITTINGS ON ALL CONDUITS

CROSSING EXPANSION JOINTS. SEE STRUCTURAL DRAWINGS FOR

LOCATIONS.

GENERAL SHEET NOTES:

1/8" = 1' - 0" 0 5' 10' 15' 30'

SHEET KEYNOTES:

1. PROVIDE HEAT TRACING CABLE ON FRESH WATER PIPING IN

UTILITY TRENCH. FOR ADDITIONAL INFORMATION SEE

DRAWINGS E-514, E-608, AND E-612.

M A

T C

H

LI

N E

B 2/

E -1

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

B

D

E

F

3031323334353637

C

2067 2220

41 41 41 19 42

41 41 41 19 43

44 44 44 19 45

44 44 44 19 46

9 19

20 28

41 4141

41 4141

1946 44

1945 44

20 2854

C PIERL

FRONT

FRONT

TMH-CD-3334

HIGH MAST

LIGHTING

POLE LC1

7 19 8

EMH-DE-3334

EMH-BC-3334

H

P1-HTCP-8

H

P1-HTCP-4

P1W-MPC-PMA-1

P1W-MPC-PMA-3

P1W-MPC-PMB-3

P1W-MPC-PMB-1

M

M

491623303743 0

KEY PLAN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A

TL

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:1

:3

P M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In iti a ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1

-E

.r v t

E-102

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

E

LE

C

TR

IC

A

L D

E C

K P

LA

N

S

H E

E T

O

F

RJW

12936761

DPF GLV

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T , R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

WRB

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

E -1

PLAN

NORTH

SCALE: 1/8" = 1'-0"

ELECTRICAL DECK PLAN - SHEET 2 OF 7

B2

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES, SEE

DRAWING E-001. FOR POWER AND COMMUNICATIONS ONE LINE

DIAGRAMS SEE DRAWINGS E-601, E-602, E-603 AND E-604. FOR FEEDER

SCHEDULE SEE DRAWINGS E-614 AND E-615.

2. PROVIDE EXPANSION/DEFLECTION FITTINGS ON ALL CONDUITS

CROSSING EXPANSION JOINTS. SEE STRUCTURAL DRAWINGS FOR

LOCATIONS.

GENERAL SHEET NOTES:

M A

T C

H

LI

N E

B 2/

E -1

M A

T C

H

LI

N E

B 2/

E -1

SHEET KEYNOTES:

1. SANITARY SEWER HEATED ENCLOSURE. SEE MECHANICAL DRAWINGS

FOR DETAILS.

2. COMPRESSED AIR AND FRESH WATER HEATED ENCLOSURE. SEE

MECHANICAL DRAWINGS FOR DETAILS.

3. POWER MOUND P1W-PMA. SEE DETAILS ON DRAWINGS E-503 AND E-504.

4. POWER MOUND P1W-PMB. SEE DETAILS ON DRAWINGS E-503 AND E-504.

5. PROVIDE HEAT TRACING CABLE ON FRESH WATER PIPING IN UTILITY

TRENCH. FOR ADDITIONAL INFORMATION SEE DRAWINGS E-514, E-608,

AND E-612.

6. MANUAL TRANSFER SWITCH AND PORTABLE EQUIPMENT RECEPTACLE

SERVING BACKUP POWER TO SEWER PUMP CONTROLLER. MOUNT

EQUIPMENT TO TYPE 316 STAINLESS STEEL STRUT SUPPORTS. SEE

FEEDER 31 ON FEEDER SCHEDULE FOR CONDUIT AND WIRE TO EXTEND

FROM EMH-BC-3334 TO TRANSFER SWITCH.

7. PROVIDE HEAT TRACING CABLE ON EXPOSED SEWER PIPING. FOR

ADDITIONAL INFORMATION SEE DRAWINGS E-514, E-608, AND E-612.

8. HIGH MAST LIGHTING POLE LC1. FOR HIGH MAST LIGHT POLE SCHEDULE

AND DETAILS SEE DRAWINGS E-508 AND E-509. SEE FEEDER 64 FOR

CONDUIT AND WIRING FROM EMH-BC-4142 TO POLE. EMH-BC-4142 IS

SHOWN ON DRAWING E-101.

9. SEE P1W-MPC-PMB PANEL SCHEDULE ON DRAWING E-606 FOR CONDUIT

AND WIRING FROM PANEL ENCLOSURE UNIT HEATER AND ALARM BOX.

10. SEE P1W-MPC-PMA PANEL SCHEDULE ON DRAWING E-606 FOR CONDUIT

AND WIRING FROM PANEL ENCLOSURE UNIT HEATER AND ALARM BOX.

11. PANEL P1W-MPC-PMB. SEE PANEL SCHEDULE ON DRAWING E-606. SEE

FEEDER 61 FOR CONDUIT AND WIRING FROM EMH-DE-3334 TO PANEL.

MOUNT EQUIPMENT TO TYPE 316 STAINLESS STEEL STRUT SUPPORTS.

12. PANEL P1W-MPC-PMA. SEE PANEL SCHEDULE ON DRAWING E-606. SEE

FEEDER 60 FOR CONDUIT AND WIRING FROM EMH-BC-3334 TO PANEL.

MOUNT EQUIPMENT TO TYPE 316 STAINLESS STEEL STRUT SUPPORTS.

13. MANUAL TRANSFER SWITCH AND PORTABLE EQUIPMENT RECEPTACLE

SERVING BACKUP POWER TO SEWER PUMP CONTROLLER. MOUNT

EQUIPMENT TO TYPE 316 STAINLESS STEEL STRUT SUPPORTS. SEE

FEEDER 31 ON FEEDER SCHEDULE FOR CONDUIT AND WIRE TO EXTEND

FROM EMH-DE-3334 TO TRANSFER SWITCH.

14. SEE COMMUNICATIONS ONE LINE DIAGRAM AND FEEDER SCHEDULE FOR

CONDUIT AND WIRING FROM WATER ENCLOSURE AMI METER TO

COMMUNICATIONS MANHOLE SYSTEM.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

D

E

F

242526272829

C

19 8

C PIERL

TMH-CD-2930

H

H

P1-HTCP-23

191919

EMH-CD-2930

P1-HTCP-9

H

P1-HTCP-11

H

P1-HTCP-6

491623303743 0

KEY PLAN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A

TL

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:1

:4

P M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In iti a ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1

-E

.r v t

E-103

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

E

LE

C

TR

IC

A

L D

E C

K P

LA

N

S

H E

E T

O

F

RJW

12936762

DPF GLV

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T , R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

WRB

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

E -1

PLAN

NORTH

SCALE: 1/8" = 1'-0"

ELECTRICAL DECK PLAN - SHEET 3 OF 7

B2

1/8" = 1' - 0" 0 5' 10' 15' 30'

SHEET KEYNOTES:

1. PROVIDE HEAT TRACING CABLE ON EXPOSED SEWER PIPING.

FOR ADDITIONAL INFORMATION SEE DRAWINGS E-514, E-608,

AND E-612.

2. PROVIDE HEAT TRACING CABLE ON FRESH WATER PIPING IN

UTILITY TRENCH. FOR ADDITIONAL INFORMATION SEE

DRAWINGS E-514, E-608, AND E-612.

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES, SEE

DRAWING E-001. FOR POWER AND COMMUNICATIONS ONE LINE

DIAGRAMS SEE DRAWINGS E-601, E-602, E-603 AND E-604. FOR FEEDER

SCHEDULE SEE DRAWINGS E-614 AND E-615.

2. PROVIDE EXPANSION/DEFLECTION FITTINGS ON ALL CONDUITS

CROSSING EXPANSION JOINTS. SEE STRUCTURAL DRAWINGS FOR

LOCATIONS.

GENERAL SHEET NOTES:

M A

T C

H

LI

N E

B 2/

E -1

M A

T C

H

LI

N E

B 2/

E -1

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

D

E

F

17181920212223

C

19 8

C PIERL

EMH-CD-1920

191919

19 8

191919

TMH-CD-1920

P1-HTCP-2

H

491623303743 0

KEY PLAN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A

TL

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:1

:4

P M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In iti a ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1

-E

.r v t

E-104

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

E

LE

C

TR

IC

A

L D

E C

K P

LA

N

S

H E

E T

O

F

RJW

12936763

DPF GLV

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T , R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

WRB

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

E -1

PLAN

NORTH

SCALE: 1/8" = 1'-0"

ELECTRICAL DECK PLAN - SHEET 4 OF 7

B2

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES, SEE

DRAWING E-001. FOR POWER AND COMMUNICATIONS ONE LINE

DIAGRAMS SEE DRAWINGS E-601, E-602, E-603 AND E-604. FOR FEEDER

SCHEDULE SEE DRAWINGS E-614 AND E-615.

2. PROVIDE EXPANSION/DEFLECTION FITTINGS ON ALL CONDUITS

CROSSING EXPANSION JOINTS. SEE STRUCTURAL DRAWINGS FOR

LOCATIONS.

GENERAL SHEET NOTES:

M A

T C

H

LI

N E

B 2/

E -1

M A

T C

H

LI

N E

B 2/

E -1

SHEET KEYNOTES:

1. PROVIDE HEAT TRACING CABLE ON FRESH WATER PIPING IN

UTILITY TRENCH. FOR ADDITIONAL INFORMATION SEE

DRAWINGS E-514, E-608, AND E-612.

2. PROVIDE HEAT TRACING CABLE ON EXPOSED SEWER PIPING.

FOR ADDITIONAL INFORMATION SEE DRAWINGS E-514, E-608,

AND E-612.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

10111213141516

10 10 10 19 11

10 10 10 19 14

38 38 38 19 39

38 38 38 19 40

10 1010

10 1010

38 3838

38 3838

20 28

20 28

C PIERL

FRONT

FRONT

TMH-CD-1314

EMH-DE-1314

H

H

H

P1-HTCP-21

P1-HTCP-17

P1-HTCP-19

P1-HTCP-15

HIGH MAST

LIGHTING

POLE LC2

19 19 19

EMH-BC-1314

EMH-DE-0910

EMH-BC-0910

TMH-CD-0910

EMH-CD-0910

HH

P1-HTCP-3P1-HTCP-7

P1-HTCP-1

HH

H

P1-HTCP-5

P1E-MPC-PMA-3

P1E-MPC-PMA-1

P1E-MPC-PMB-1

P1E-MPC-PMB-3

M

M

14 11

491623303743 0

KEY PLAN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A

TL

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:1

:5

P M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In iti a ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1

-E

.r v t

E-105

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

E

LE

C

TR

IC

A

L D

E C

K P

LA

N

S

H E

E T

O

F

RJW

12936764

DPF GLV

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T , R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

WRB

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

E -1

PLAN

NORTH

SCALE: 1/8" = 1'-0"

ELECTRICAL DECK PLAN - SHEET 5 OF 7

B2

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES, SEE

DRAWING E-001. FOR POWER AND COMMUNICATIONS ONE LINE

DIAGRAMS SEE DRAWINGS E-601, E-602, E-603 AND E-604. FOR FEEDER

SCHEDULE SEE DRAWINGS E-614 AND E-615.

2. PROVIDE EXPANSION/DEFLECTION FITTINGS ON ALL CONDUITS

CROSSING EXPANSION JOINTS. SEE STRUCTURAL DRAWINGS FOR

LOCATIONS.

GENERAL SHEET NOTES:

M A

T C

H

LI

N E

B 2/

E -1

M A

T C

H

LI

N E

B 2/

E -1

SHEET KEYNOTES:

1. SANITARY SEWER HEATED ENCLOSURE. SEE MECHANICAL DRAWINGS

FOR DETAILS.

2. COMPRESSED AIR AND FRESH WATER HEATED ENCLOSURE. SEE

MECHANICAL DRAWINGS FOR DETAILS.

3. POWER MOUND P1E-PMA. SEE DETAILS ON DRAWINGS E-503 AND E-504.

4. POWER MOUND P1E-PMB. SEE DETAILS ON DRAWINGS E-503 AND E-504.

5. PROVIDE HEAT TRACING CABLE ON FRESH WATER PIPING IN UTILITY

TRENCH. FOR ADDITIONAL INFORMATION SEE DRAWINGS E-514, E-608,

AND E-612.

6. MOUNT TRANSFER SWITCH AND PORTABLE EQUIPMENT RECEPTACLE

SERVING BACKUP POWER TO SEWER PUMP CONTROLLER. MOUNT

EQUIPMENT TO TYPE 316 STAINLESS STEEL STRUT SUPPORTS. SEE

FEEDER 32 ON FEEDER SCHEDULE FOR CONDUIT AND WIRE TO EXTEND

FROM EMH-BC-1314 TO TRANSFER SWITCH.

7. PROVIDE HEAT TRACING CABLE ON EXPOSED SEWER PIPING. FOR

ADDITIONAL INFORMATION SEE DRAWINGS E-514, E-608, AND E-612.

8. FOR HIGH MAST LIGHT POLE SCHEDULE AND DETAILS SEE DRAWINGS

E-508 AND E-509. SEE FEEDER 65 FOR CONDUIT AND WIRING FROM EMH-

DE-3334 TO POLE. EMH-DE-3334 IS SHOWN ON DRAWING E-102.

9. SEE P1E-MPC-PMB PANEL SCHEDULE ON DRAWING E-606 FOR CONDUIT

AND WIRING FROM PANEL ENCLOSURE UNIT HEATER AND ALARM BOX.

10. SEE P1E-MPC-PMA PANEL SCHEDULE ON DRAWING E-606 FOR CONDUIT

AND WIRING FROM PANEL ENCLOSURE UNIT HEATER AND ALARM BOX.

11. PANEL P1E-MPC-PMB. SEE PANEL SCHEDULE ON DRAWING E-606. SEE

FEEDER 63 FOR CONDUIT AND WIRING FROM EMH-BC-1314 TO PANEL.

MOUNT EQUIPMENT TO TYPE 316 STAINLESS STEEL STRUT SUPPORTS.

12. PANEL P1E-MPC-PMA. SEE PANEL SCHEDULE ON DRAWING E-606. SEE

FEEDER 62 FOR CONDUIT AND WIRING FROM EMH-DE-1314 TO PANEL.

MOUNT EQUIPMENT TO TYPE 316 STAINLESS STEEL STRUT SUPPORTS.

13. MANUAL TRANSFER SWITCH AND PORTABLE EQUIPMENT RECEPTACLE

SERVING BACKUP POWER TO SEWER PUMP CONTROLLER. MOUNT

EQUIPMENT TO TYPE 316 STAINLESS STEEL STRUT SUPPORTS. SEE

FEEDER 32 ON FEEDER SCHEDULE FOR CONDUIT AND WIRE TO EXTEND

FROM EMH-DE-1314 TO TRANSFER SWITCH.

14. SEE COMMUNICATIONS ONE LINE DIAGRAM AND FEEDER SCHEDULE FOR

CONDUIT AND WIRING FROM WATER ENCLOSURE AMI METER TO

COMMUNICATIONS MANHOLE SYSTEM.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

56789

10 10 10 19 11

10 10 10 19 14

38 38 38 19 39

38 38 38 19 40 19 9 19 8

SUBSTATION P1E

59 673623 2020

38 38 38 19 39

48 53

13 49 12 72

E-402 C1

C PIERL

13 49 12 72

EMH-DE-0405

EMH-DE-0607

19 19 19 1919

19 9 19 87

19 19 19 1919

23 6920

20 6824

38 38 38 19 40 13 72

EMH-CD-0405TMH-CD-0506

EMH-EF-0607 20 20

20 20

19 56194

491623303743 0

KEY PLAN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A

TL

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:1

:5

P M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In iti a ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1

-E

.r v t

E-106

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

E

LE

C

TR

IC

A

L D

E C

K P

LA

N

S

H E

E T

O

F

RJW

12936765

DPF GLV

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T , R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

WRB

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

E -1

PLAN

NORTH

SCALE: 1/8" = 1'-0"

ELECTRICAL DECK PLAN - SHEET 6 OF 7

B2

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES, SEE

DRAWING E-001. FOR POWER AND COMMUNICATIONS ONE LINE

DIAGRAMS SEE DRAWINGS E-601, E-602, E-603 AND E-604. FOR FEEDER

SCHEDULE SEE DRAWINGS E-614 AND E-615.

2. PROVIDE EXPANSION/DEFLECTION FITTINGS ON ALL CONDUITS

CROSSING EXPANSION JOINTS. SEE STRUCTURAL DRAWINGS FOR

LOCATIONS.

GENERAL SHEET NOTES:

M A

T C

H

LI

N E

B 2/

E -1

M A

T C

H

LI

N E

B 2/

E -1

SHEET KEYNOTES:

1. PROVIDE HEAT TRACING CABLE ON EXPOSED SEWER PIPING.

FOR ADDITIONAL INFORMATION SEE DRAWINGS E-514, E-608,

AND E-612.

2. PROVIDE HEAT TRACING CABLE ON FRESH WATER PIPING IN

UTILITY TRENCH. FOR ADDITIONAL INFORMATION SEE

DRAWINGS E-514, E-608, AND E-612.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

34 012

7 19 9 19

24 20 68

20 23

4 19 6 19 5

AIR COMPRESSOR ENCLOSURE 1

721213 49

C PIERL

EMH-P1-4

19 19 19 19 19

C1

E-513

C2

E-513

P1-HTCP-13

H

20 20

491623303743 0

KEY PLAN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A

TL

A N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

06 FEB 2026

LCDR Samuel Newton ROICC

/2

/2

:1

:0

P M

A u to d e s k D o c s /2

U

S C

G O

C R

H o m e p o rt

In iti a ti v e O

P C

P ie r_

/P

IE

R

U S

C G

-1

-E

.r v t

E-107

U S

C G

O C

R H

O M

E P

O R

T

IN

IT

IA

T

IV

E O

P C

P

IE

R

E

LE

C

TR

IC

A

L D

E C

K P

LA

N

S

H E

E T

O

F

RJW

12936766

DPF GLV

Frank Cole USCG MASI

MRI/CWJ

1826479

N E

W P

O R

T , R

I N

A V

A L

S T

A T

IO

N

N E

W P

O R

T

JWJ

WRB

HPN

C I

C O

R E

H

A M

P T

O N

R O

A D

S

E -1

PLAN

NORTH

SCALE: 1/8" = 1'-0"

ELECTRICAL DECK PLAN - SHEET 7 OF 7

A2

SHEET KEYNOTES:

1. MAKE CONNECTION TO EXTERIOR DISCONNECT SWITCH

PROVIDED WITH ELEVATED AIR COMPRESSOR. SEE MECHANICAL

DRAWINGS FOR DETAILS OF AIR COMPRESSOR ENCLOSURE. SEE

DRAWING E-513 FOR ADDITIONAL DETAILS ON CONDUIT RUN

FROM UNDERGROUND UP TO DISCONNECT SWITCH.

2. PROVIDE ELECTRICAL MANHOLE. SEE DETAIL ON E-501.

3. PROVIDE HEAT TRACING CABLE ON FRESH WATER PIPING IN

UTILITY TRENCH. FOR ADDITIONAL INFORMATION SEE DRAWINGS

E-514, E-608, AND E-612.

4. PROVIDE HEAT TRACING CABLE ON EXPOSED SEWER PIPING.

FOR ADDITIONAL INFORMATION SEE DRAWINGS E-514, E-608, AND

E-612.

5. TERMINATE HEAT TRACING CIRCUIT AT PIPE PENETRATION

THROUGH BULKHEAD.

6. PROVIDE WATERTIGHT CONDUIT PENETRATION THROUGH

EXISTING BULKHEAD.

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES, SEE

DRAWING E-001. FOR POWER AND COMMUNICATIONS ONE LINE

DIAGRAMS SEE DRAWINGS E-601, E-602, E-603 AND E-604. FOR FEEDER

SCHEDULE SEE DRAWINGS E-614 AND E-615.

2. PROVIDE EXPANSION/DEFLECTION FITTINGS ON ALL CONDUITS

CROSSING EXPANSION JOINTS. SEE STRUCTURAL DRAWINGS FOR

LOCATIONS.

GENERAL SHEET NOTES:

M A

T C

H

LI

N E

B 2/

E -1

M A

T C

H

LI

N E

S E

E E

-1

1/8" = 1' - 0" 0 5' 10' 15' 30'

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

XXX

X

X

X

X

X

X

X

X

X

X

X

X

X

E

E

E

T

X X X

X X X

T

T

W

X X

X

X

E

T

X

T

X

SS

Cx

Cx

C x

C x

Cx Cx

Cx

(E) TMH "M"

USCG MAT BUILDING 1406

(E) TMH "N"

(E) TMH "O"

(E) TMH "Q"

(E) EMH4580E

(E) EMH4118E

(E) EMH4121E

(E) EMH4119E

2 19 3

2 19 19 19

2 19 19 19

6EMH P1-5 EMH P1-6

(E) EMH4120E

(E) EMH4582E(E) EMH4116E

Cx CxCx Cx

C

LIMIT OF DISTURBANCE, TYP

IR ZONE BOUNDARY

X E

E

E

E

E

E

E

W

T

T

W

T

W

T

T

W

T

E

E

T

T

W

W

W

W

W

E

T

W

E

E

E

T

E

E

E

T

E

T

E

E

E

W

ACU

CR

CR

CR

ACU

ACU

CR ACU

M

M

CR

ACU

CR

M

D

D

D

D

D

D

D

D

D D

DD

G

D

D

D

D

D

D

E-108

EL

EC

TR

IC

AL

S

IT

E

PL

AN

PI

ER

DPF GLV RJW

PLAN

NORTH

1" = 50' 50' 0 50' 100'

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

- M

ID

-A

TL

AN

TI

C

CI

C

OR

E

- H

AM

PT

ON

R

OA

DS

NA

VA

L S

TA

TI

ON

NO

RF

OL

K, V

A

NA

VA

L

ST

AT

IO

N

NE

W

PO

RT

NE

W

PO

RT

, R

I

US

CG

O

CR

H O

M

EP

O

RT

IN

IT

IA

TI

VE

O

PC

P

IE

R

MRI/CWJ

JWJ

HPN

1826479

WRB

LCDR Samuel Newton ROICC

Frank Cole USGC MASI

06 FEB 2026MA

TC

HL

IN

E

A2 /E-

PIER 2

BURMA ROAD

PIER ACCESS ROAD

GENERAL SHEET NOTES:

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES SEE

DRAWINGS E-001.

2. FOR SITE POWER AND COMMUNICATIONS ONE LINE DIAGRAMS SEE

DRAWINGS E-601 AND E-604. FOR FEEDER SCHEDULES SEE DRAWINGS

E-614 AND E-615.

SHEET KEYNOTES:

1. ROUTE CABLING IN EXISTING SPARE DUCTS.

2. PROVIDE CONCRETE ENCASED DUCTBANK.

3. SEE DETAIL B1/C-502 FOR TRENCH REPAIR WORK.

4. SEE DETAIL B2/C-502 FOR TRENCH REPAIR WORK.

5. SEE DETAIL C2/C-502 FOR TRENCH REPAIR WORK.

6. PROVIDE ELECTRICAL MANHOLE.

KEY PLAN

1" = 50'SCALE:

ELECTRICAL SITE PLAN - PIER 2A2

12936767

X X X X

X

X

X

X

XXXXXXXX

X

X X

X X X X X X

X

X X

X

E

E

E

W

T W

T

T

E

T

X X X

X X X X X

E

E

S S

E

E

W W

W W W W W

S

S S

S S S

S S

S

W

G G

G G

G G

G G

G

G

G

G

G

G

CR

Cx Cx

Cx

Cx

Cx

Cx

Cx

Cx

Cx Cx

G G G

G

G

G G G G G G G G G G G

G

G

SS

SS

SS SS SS SS

D

D

D

SD

D

SS

D

D

W

W

(E) TMH "K"

(E) TMH "J"

(E) TMH "I"

(E) TMH-4

(E) TMH-3

(E) EMH4121AE

(E) EMH4122E

(E) EMH4123E

(E) EMH-L8

EMH P1-1

EMH P1-2

EMH P1-3

COMPRESSED AIR ENCLOSURE

SEWER LIFT

STATION

15KV SWITCH P1W-SW

1 19

2023 24

19 5194 6

19 64

124913 72

6 2

20682

3 TYP

EMH P1-4

SEE DRAWING E-502 FOR 15KV

SWITCHGEAR STRUCTURE DETAILS

Cx Cx

COMMUNICATIONS MANHOLE SERVING

IDA LEWIS SHORE TIE STATIONCOMMUNICATIONS

MANHOLE SERVING WILLOW

SHORE TIE STATION

19 5

19 97 19 8 19 1919 19 19 2

EMH P1-3A

191919 19

1919 19 1919 19 2

EMH P1-2A

1 2

19 2

2 19 19 19

2 19 19 19

SUBSTATION 1 9

EMH P1-7

EMH P1-8

1919 191919

199 8 2

49 10

13 1010 71

RPZ

70 10

2 5

15KV SWITCH P1E-SW

Cx

LIMIT OF DISTURBANCE, TYP

IR ZONE BOUNDARY

5 812 X

E

E

E

E

E

E

E

W

T

T

W

T

W

T

T

W

T

E

E

T

T

W

W

W

W

W

E

T

W

E

E

E

T

E

E

E

T

E

T

E

E

E

W

ACU

CR

CR

CR

ACU

ACU

CR ACU

M

M

CR

T T

ACU

CR

M

D

D

D

D

D

D

D

D

D D

DD

G

D

D

D

D

D

D

(E) TMH "M"

(E) TMH "K"

(E) TMH "J"

(E) TMH "I"

(E) TMH-4

(E) TMH-3

(E) TMH-2

(E) TMH-1

(E) TMH "F"

(E) TMH "E"

(E) TMH "D"

(E) TMH "C"

(E) TMH "B"

(E) TMH "A"

BUILDING 76

USCG MAT BUILDING 1406

(E) TMH "N"

(E) TMH "O"

(E) TMH "Q"

(E) EMH4580E

(E) EMH4118E

(E) EMH4121AE

(E) EMH4121E

(E) EMH4122E

(E) EMH4123E

(E) EMH-L8

EMH P1-1

EMH P1-2

EMH P1-3

COMPRESSED AIR ENCLOSURE

(E) EMH4119E

SEWER LIFT

STATION

15KV SWITCH P1W-SW

2 19 3

1 19

20 23 24

19 5194 6

19 64

124913 72

20 24

20 24

20 682

3 TYP

2 TYP

EMH P1-4

SEE DRAWING E-502 FOR 15KV

SWITCHGEAR STRUCTURE DETAILS

COMMUNICATIONS MANHOLE SERVING

IDA LEWIS SHORE TIE STATIONCOMMUNICATIONS

MANHOLE SERVING WILLOW

SHORE TIE STATION

19 5

19 97 19 8 19 1919 19 19 2

EMH P1-3A

191919 19

1919 19 1919 19 2

EMH P1-2A

1 2

19 2

2 19 19 19

2 19 19 19

2 19 19 19

2 19 19 19

SUBSTATION 1 9

EMH P1-5 EMH P1-6

EMH P1-7

EMH P1-8

69 81

1919 19 1919

199 8 2

49 10

13 1010 71

RPZ

70 10

2 5

23 69

15KV SWITCH P1E-SW

(E) EMH4121AE

(E) EMH4236E

(E) EMH4120E

(E) EMH4582E(E) EMH4116E

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

IR ZONE BOUNDARY

IR ZONE BOUNDARY

IR ZONE BOUNDARY

5 812

E-109

EL

EC

TR

IC

AL

S

IT

E

PL

AN

PI

ER

DPF GLV RJW

1" = 50'SCALE:

ELECTRICAL SITE PLAN - PIER 1A2

PLAN

NORTH

1" = 50' 50' 0 50' 100'

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

- M

ID

-A

TL

AN

TI

C

CI

C

OR

E

- H

AM

PT

ON

R

OA

DS

NA

VA

L S

TA

TI

ON

NO

RF

OL

K, V

A

NA

VA

L

ST

AT

IO

N

NE

W

PO

RT

NE

W

PO

RT

, R

I

US

CG

O

CR

H O

M

EP

O

RT

IN

IT

IA

TI

VE

O

PC

P

IE

R

MRI/CWJ

JWJ

LCDR Samuel Newton ROICC

Frank Cole USGC MASI

06 FEB 2026

MA

TC

HL

IN

E A2

/E -1

MA

TC

HL

IN

E A2

/E -1

FOR CONTINUATION SEE E-107

PIER ACCESS ROAD

PIER ACCESS ROAD

BURMA ROAD

AC

CE

SS

R

OA

D

GENERAL SHEET NOTES:

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES SEE

DRAWINGS E-001.

2. FOR SITE POWER AND COMMUNICATIONS ONE LINE DIAGRAMS SEE

DRAWINGS E-601 AND E-604. FOR FEEDER SCHEDULES SEE DRAWINGS

E-614 AND E-615.

SHEET KEYNOTES:

1. PROVIDE CONCRETE ENCASED DUCTBANK PARALLEL TO EXISTING

DUCTBANK BETWEEN MANHOLES.

2. PROVIDE CONCRETE ENCASED DUCTBANK.

3. ROUTE FEEDER 24 THROUGH EXISTING SPARE DUCTS FROM TMH "I"

TO TMH "F", WHICH IS SHOWN ON DRAWING E-110.

4. STAND MOUNTED DUPLEX PUMP CONTROL PANEL FOR LIFT STATION.

SEE DETAIL C4/E-513.

5. SEE DETAIL B1/C-502 FOR TRENCH REPAIR WORK.

6. SEE DETAIL B2/C-502 FOR TRENCH REPAIR WORK.

7. SEE DETAIL C2/C-502 FOR TRENCH REPAIR WORK.

8. PROVIDE ELECTRICAL MANHOLE.

9. FOR ADDITIONAL WORK IN SUBSTATION 1 SEE ES DRAWINGS.

10. PROVIDE DIRECT BURIED CONDUIT.

11. PROVIDE PANEL P1E-MPC-RPZ. SEE PANEL SCHEDULE ON E-606.

PROVIDE DIRECT BURIED CONDUITS FROM PANEL TO RPZ ENCLOSURE

AND LIFT STATION COMMUNICATIONS ENCLOSURE, SEE PANEL

SCHEDULE FOR CONDUIT & WIRE. SEE DETAIL B4/E-513 FOR PANEL

MOUNTING.

12. COORDINATE DUCTBANK RAIL CROSSING WITH RIDOT. THE

CONTRACTOR WILL NOTIFY THE CONTRACTING OFFICER IN WRITING A

MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO PERFORMING ANY

WORK WITHIN OR ADJACENT TO THE RAILROAD EASEMENT AREA. NO

WORK WILL BE PERFORMED BY THE CONTRACTOR WITHIN THE

RAILROAD EASEMENT AREA UNTIL THE REQUIRED EASEMENT OR

AUTHORIZATION HAS BEEN OBTAINED BY THE GOVERNMENT AND THE

CONTRACTOR HAS RECEIVED WRITTEN NOTICE FROM THE

CONTRACTING OFFICER AUTHORIZING WORK WITHIN THE EASEMENT

AREA.

13. STAND MOUNTED COMMUNICATIONS ENCLOSURE FOR LIFT STATION.

ENCLOSURE TO BE 36"W x 36"T x 10"D. ENCLOSURE TO HAVE DUPLEX

RECEPTACLE, AUTODIALER (SEE SPEC SECTION 33 32 16), 50 PAIR 110

BLOCK, AND 25 PAIR 710/110 BUILDING ENTRANCE PROTECTOR. SEE

DETAIL C4/E-513.

KEY PLAN

12936768

X

X

X

XX

X

X

X

X X X X

X X

X X

X

XE

W

W W

W

W

W W

W

W

E

T

E

E

T

E

T

E

G

G G

C x

C x

C x

ACU

CR

CR

ACU

ACU

CR ACU

M

M

T T

ACU

CR

M

D

D

D

D

D

D

D

D

D D

DD

G G G G G G G G

G

G

(E) TMH-2

(E) TMH-1

(E) TMH "F"

(E) TMH "E"

(E) TMH "D"

2 TYP

(E) EMH4121AE

(E) EMH4236E

LIMIT OF DISTURBANCE, TYP

IR ZONE BOUNDARY

X E

E

E

E

E

E

E

W

T

T

W

T

W

T

T

W

T

E

E

T

T

W

W

W

W

W

E

T

W

E

E

E

T

E

E

E

T

E

T

E

E

E

W

ACU

CR

CR

CR

ACU

ACU

CR ACU

M

M

CR

T T

ACU

CR

M

D

D

D

D

D

D

D

D

D D

DD

G

D

D

D

D

D

D

(E) TMH "M"

(E) TMH "K"

(E) TMH "J"

(E) TMH "I"

(E) TMH-4

(E) TMH-3

(E) TMH-2

(E) TMH-1

(E) TMH "F"

(E) TMH "E"

(E) TMH "D"

(E) TMH "C"

(E) TMH "B"

(E) TMH "A"

BUILDING 76

USCG MAT BUILDING 1406

(E) TMH "N"

(E) TMH "O"

(E) TMH "Q"

(E) EMH4580E

(E) EMH4118E

(E) EMH4121AE

(E) EMH4121E

(E) EMH4122E

(E) EMH4123E

(E) EMH-L8

EMH P1-1

EMH P1-2

EMH P1-3

COMPRESSED AIR ENCLOSURE

(E) EMH4119E

SEWER LIFT

STATION

15KV SWITCH P1W-SW

2 19 3

1 19

20 23 24

19 5194 6

19 64

124913 72

20 24

20 24

20 682

3 TYP

2 TYP

EMH P1-4

SEE DRAWING E-502 FOR 15KV

SWITCHGEAR STRUCTURE DETAILS

COMMUNICATIONS MANHOLE SERVING

IDA LEWIS SHORE TIE STATIONCOMMUNICATIONS

MANHOLE SERVING WILLOW

SHORE TIE STATION

19 5

19 97 19 8 19 1919 19 19 2

EMH P1-3A

191919 19

1919 19 1919 19 2

EMH P1-2A

1 2

19 2

2 19 19 19

2 19 19 19

2 19 19 19

2 19 19 19

SUBSTATION 1 9

EMH P1-5 EMH P1-6

EMH P1-7

EMH P1-8

69 81

1919 19 1919

199 8 2

49 10

13 1010 71

RPZ

70 10

2 5

23 69

15KV SWITCH P1E-SW

(E) EMH4121AE

(E) EMH4236E

(E) EMH4120E

(E) EMH4582E(E) EMH4116E

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

IR ZONE BOUNDARY

IR ZONE BOUNDARY

IR ZONE BOUNDARY

5 812

E-110

EL

EC

TR

IC

AL

S

IT

E

PL

AN

NO

AA

B

UI

LD

IN

G

DPF GLV RJW

PLAN

NORTH

1" = 50' 50' 0 50' 100'

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

- M

ID

-A

TL

AN

TI

C

CI

C

OR

E

- H

AM

PT

ON

R

OA

DS

NA

VA

L S

TA

TI

ON

NO

RF

OL

K, V

A

NA

VA

L

ST

AT

IO

N

NE

W

PO

RT

NE

W

PO

RT

, R

I

US

CG

O

CR

H O

M

EP

O

RT

IN

IT

IA

TI

VE

O

PC

P

IE

R

MRI/CWJ

JWJ

LCDR Samuel Newton ROICC

Frank Cole USGC MASI

06 FEB 2026

MATCHLINE A2/E-111

MA

TC

HL

IN

E A2

/E -1

PIER ACCESS ROAD

AN

DE

RS

EN

A

VE

GENERAL SHEET NOTES:

1. FOR ELECTRICAL ABBREVIATIONS, LEGEND & GENERAL NOTES SEE

DRAWINGS E-001.

2. FOR SITE POWER AND COMMUNICATIONS ONE LINE DIAGRAMS SEE

DRAWINGS E-601 AND E-604. FOR FEEDER SCHEDULES SEE DRAWINGS

E-614 AND E-615.

3. BACKGROUND UTILITIES SHOWN ARE IMPORTED FROM THE NOAA PIER

PROJECT DRAWINGS AND WERE NOT DEVELOPED BY THE SURVEY

UNDER THIS CONTRACT.

SHEET KEYNOTES:

1. PROVIDE CONCRETE ENCASED DUCTBANK PARALLEL TO EXISTING

DUCTBANK BETWEEN MANHOLES.

2. ROUTE FEEDER 24 THROUGH EXISTING SPARE DUCTS FROM TMH "F"

TO TMH "I, WHICH IS SHOWN ON DRAWING E-109.

3. SEE DETAIL B1/C-502 FOR TRENCH REPAIR WORK.

4. COORDINATE DUCTBANK RAIL CROSSING WITH RIDOT. THE

CONTRACTOR WILL NOTIFY THE CONTRACTING OFFICER IN WRITING A

MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO PERFORMING ANY

WORK WITHIN OR ADJACENT TO THE RAILROAD EASEMENT AREA. NO

WORK WILL BE PERFORMED BY THE CONTRACTOR WITHIN THE

RAILROAD EASEMENT AREA UNTIL THE REQUIRED EASEMENT OR

AUTHORIZATION HAS BEEN OBTAINED BY THE GOVERNMENT AND THE

CONTRACTOR HAS RECEIVED WRITTEN NOTICE FROM THE

CONTRACTING OFFICER AUTHORIZING WORK WITHIN THE EASEMENT

AREA.

KEY PLAN1" = 50'SCALE:

ELECTRICAL SITE PLAN - NOAA BUILDINGA2

12936769

E

C x

C x

C x

C x

C x

Cx Cx

Cx

Cx

(E) TMH "C"

(E) TMH "B"

(E) TMH "A"

BUILDING 76

2 LIMIT OF DISTURBANCE, TYP

X E

E

E

E

E

E

E

W

T

T

W

T

W

T

T

W

T

E

E

T

T

W

W

W

W

W

E

T

W

E

E

E

T

E

E

E

T

E

T

E

E

E

W

ACU

CR

CR

CR

ACU

ACU

CR ACU

M

M

CR

T T

ACU

CR

M

D

D

D

D

D

D

D

D

D D

DD

G

D

D

D

D

D

D

(E) TMH "M"

(E) TMH "K"

(E) TMH "J"

(E) TMH "I"

(E) TMH-4

(E) TMH-3

(E) TMH-2

(E) TMH-1

(E) TMH "F"

(E) TMH "E"

(E) TMH "D"

(E) TMH "C"

(E) TMH "B"

(E) TMH "A"

BUILDING 76

USCG MAT BUILDING 1406

(E) TMH "N"

(E) TMH "O"

(E) TMH "Q"

(E) EMH4580E

(E) EMH4118E

(E) EMH4121AE

(E) EMH4121E

(E) EMH4122E

(E) EMH4123E

(E) EMH-L8

EMH P1-1

EMH P1-2

EMH P1-3

COMPRESSED AIR ENCLOSURE

(E) EMH4119E

SEWER LIFT

STATION

15KV SWITCH P1W-SW

2 19 3

1 19

20 23 24

19 5194 6

19 64

124913 72

20 24

20 24

20 682

3 TYP

2 TYP

EMH P1-4

SEE DRAWING E-502 FOR 15KV

SWITCHGEAR STRUCTURE DETAILS

COMMUNICATIONS MANHOLE SERVING

IDA LEWIS SHORE TIE STATIONCOMMUNICATIONS

MANHOLE SERVING WILLOW

SHORE TIE STATION

19 5

19 97 19 8 19 1919 19 19 2

EMH P1-3A

191919 19

1919 19 1919 19 2

EMH P1-2A

1 2

19 2

2 19 19 19

2 19 19 19

2 19 19 19

2 19 19 19

SUBSTATION 1 9

EMH P1-5 EMH P1-6

EMH P1-7

EMH P1-8

69 81

1919 19 1919

199 8 2

49 10

13 1010 71

RPZ

70 10

2 5

23 69

15KV SWITCH P1E-SW

(E) EMH4121AE

(E) EMH4236E

(E) EMH4120E

(E) EMH4582E(E) EMH4116E

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

LIMIT OF DISTURBANCE, TYP

IR ZONE BOUNDARY

IR ZONE BOUNDARY

IR ZONE BOUNDARY

5 812

E-111

EL

EC

TR

IC

AL

S

IT

E

PL

AN

BU

ILD

IN

G

DPF GLV RJW

PLAN

NORTH

1" = 50' 50' 0 50' 100'

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .