W9128A-19-R-0014_Drawings_-_Package_1_(Part_5_of_11).pdf

PDF 10 MB Posted

Attached to
Quad A, Building 131 and Central Utility Plant (CUP), and Buildings 130 and 132, Schofield Barracks, Hawaii
Solicitation number
W9128A-19-R-0014
Issued by

About this file

W9128A-19-R-0014 Drawings - Package 1 (Part 5 of 11)

View the file

Other files

File Type Posted
W9128A-19-R-0014_-_Section_00_22_16,_Attachment_A.docx DOCX document
W9128A-19-R-0014_Am-0007_Drawings_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0007_Drawings_-_Package_2.pdf PDF
W9128A-19-R-0014_Am-0007_Specifications_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0007.pdf PDF
W9128A-19-R-0014_Am-0006.pdf PDF
W9128A-19-R-0014_Am-0006_Drawings_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0006_Drawings_-_Package_2.pdf PDF
W9128A-19-R-0014_Am-0005.pdf PDF
W9128A-19-R-0014_Am-0004_Specifications_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0004_Drawings_-_Package_2.pdf PDF
W9128A-19-R-0014_Am-0004.pdf PDF
W9128A-19-R-0014_Am-0004_Drawings_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0003.pdf PDF
W9128A-19-R-0014_Am-0002.pdf PDF
W9128A-19-R-0014_Am-0001_Specifications_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0001_Drawings_-_Package_2_(Part_1_of_2).pdf PDF
W9128A-19-R-0014_Am-0001_Specifications_-_Package_2.pdf PDF
W9128A-19-R-0014_Am-0001_Drawings_-_Package_2_(Part_2_of_2).pdf PDF
W9128A-19-R-0014_Am-0001.pdf PDF
W9128A-19-R-0014_Am-0001_Drawings_-_Package_1.pdf PDF
W9128A-19-R-0014_Request_for_Proposal.pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_11_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_6_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_1_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_13_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_11_of_14).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_1_(Part_3_of_3).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_2_(Part_3_of_3).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_7_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_12_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_9_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_3_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_4_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_10_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_2_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_10_of_11).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_1_(Part_2_of_3).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_2_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_8_of_11).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_2_(Part_2_of_3).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_7_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_14_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_6_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_3_of_11).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_1_(Part_1_of_3).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_9_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_1_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_4_of_11).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_2_(Part_1_of_3).pdf PDF
Show 40 more

Latest 50 of 52 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3/4 " TRAVEL

3/4 " TRAVEL 3/8 "

G1

G3

E1

H1

H1

G1

G1

G4 H1

G1

G4

E1

G1

H1

G3

G3

H1

H2

H1

H2

H1

H2

G3

G3

D1

G5

D1

G3

M1

D3

D3

H1

H1

H1

D2

C1

G2

G1

G1

H1

G3

M1 H1

P1 P1

SHEET KEYNOTES

GENERAL SHEET NOTES

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

H O

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W A

II

R E

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

I

S

C H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

N

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

T

F

IL

E N

A M

E

12:30:20 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-401.dgn

J U

N E

RTA

1'-0" 1'-0"

6"

6"

TREAD TREAD

FLOOR MOUNTED

A5A

WALL MOUNTED

A5B

BRACKETS

EQUALLY

SPACED NOT

MORE THAN

4'-0" OC

POSTS

EQUALLY

SPACED NOT

MORE THAN

4'-0" OC

EMBED 12"

INTO CONC

A5

TYPICAL HANDRAIL ELEV

1/2"=1'-0"

3/8 "R

3/4 "

R

IS

E R

TREAD

A7

DETAIL

1 1/2"=1'-0"

2 1/4 "

PLAN

C7A

ELEVATION

C7B

C7C

SECTION

C7C

A-401

C7B

A-401

/4

/4

6"

C7

RETURN

HANDRAIL

1 1/2"=1'-0"

G4

G1

G1

SIDE

TOP

FRONT

/8

/4

1 1/4 "3"1 1/4 "

2 7/8 "

/2

1.25"R

G7

DETAIL

1 1/2"=1'-0"

A8

GUARD ELEV

3RD FLR

3/4"=1'-0"

ELEVATION

1/4 "

H1 SECTION

SLIDE BOLT SLOT

INFILL

1 3/4 "

ROD SLOT

1 1/8 " SLIDE

SLIDE BOLT

3/4 "

LC

LC

R1

R2

R3

R4

R3

R4

R4

R3

(PIECE 1 OF 2)

(PIECE 2 OF 2)

SLIDE BOLT /

SLIDE ROD

ASSEMBLY

C1

REMOVABLE RAIL

3"=1'-0"

E7

DETAIL

3/4"=1'-0"

F7

DETAIL

EQ EQ

EQ EQ

6"

/4

T R

E A

D

TREAD

TREAD

TREAD

12"

12" TREAD

TREAD

DN

TREAD12"

F7

A-401

E7

A-401

12"

TREAD

TREAD

UP

TREAD 12"

C5

STAIR S03 / S04 PLAN

(STAIR S05 / S06 SIM)

F8

A-401

A8

A-401

C8

A-401

12"

12"

C7A

A-401

F1

A-401

/4

6"

7"

DN

UP

UP

T R

E A

D

3'-0"

3'-0"

NOSING NOSING

NOSING

NOSING

F8

GUARD ELEV

3RD FLR STAIR

C8

GUARD ELEV

STAIR

(DASHED

CONDITION)

3"EQEQ

3"

M

IN

1'-0"

FLR

3 R D

FLR

2 N D

FLR

1 S T

E1

STAIR S02 PLAN

E3

STAIR S07 PLAN

6'-6"

F3

STAIR S08 PLAN (S01 SIM)

F1

STAIR S08 ELEV (S01 SIM)

C7

A-401

C7

A-401

SIM

C1

A-401

C1

1/4"=1'-0" 1/4"=1'-0"

1/4"=1'-0"1/4"=1'-0"

1/4"=1'-0" 3/4"=1'-0"

3/4"=1'-0"3/4"=1'-0"

(S01)- 3 EQ RISERS @ 7"

(S08)- 2 EQ RISERS @ 7"

R

IS

E R

S

(S01)- 2T @ 12" = 2'-0"

PLAN

NORTH

1.SEE SHEET A-001 FOR GENERAL NOTES.

2.SEE SHEET A-101 FOR SHEET LEGEND.

3.EXISTING STAIRS: REMOVE ALL HANDRAILS AND GUARD.

INSTALL NEW HANDRAILS AND GUARD.

4.NEW STAIRS: CONSTRUCT STAIRS S01 AND S08 IN

ACCORDANCE WITH PLANS AND DETAILS ON SHEET A-401.

5.THE FINISH COLOR FOR ALL STAIR COMPONENTS SHALL BE

DARK BRONZE ANODIZED. COMPONENTS INCLUDE:

GUARD, HANDRAIL, POST, AND BRACKET.

SC: 3/4"=1'-0"

4" 16"0 8" 12"

SC: 1/4"=1'-0"

0 4'-0"2'-0"

SC: 1/2"=1'-0"

0 1'-0" 2'-0"

SC: 1 1/2"=1'-0"

0 8"4"0 2" 4"

SC: 3"=1'-0"

FG FINISH GRADE

E1 EXST CONC LANDING, TREAD, OR RISER

F1 CONCRETE SLAB, SEE CIVIL AND STRUCTURAL DWGS

G1 GUARD TOP, BOTTOM, AND POST:

MATERIAL:ALUMINUM

SIZE: 1.25-INCH NOM PIPE SIZE, SCHED 40, OD= 1.66"

INSTALL: INSTALL GUARD MIN 42-INCHES ABOVE STAIR

NOSING

G2 GUARD PICKET:

MATERIAL:ALUMINUM

SIZE: 0.5-INCH NOM PIPE SIZE, SCHED 40, OD= 0.84"

INSTALL: INSTALL PICKETS MAX 4.75-INCHES ON CNTR

G3 GUARD POST BRACKET W/ PIPE ADAPTER:

MATERIAL:ALUMINUM

SIZE: PER MANUFACTURER STD

G4 GUARD POST ANCHOR PLATE:

MATERIAL:ALUMINUM

SIZE: SEE DWGS

G5 GUARD OR HANDRAIL POST ESCUTCHEON PLATE:

MATERIAL:ALUMINUM

SIZE: PER MANUFACTURER STD

H1 HANDRAIL AND POST:

MATERIAL:ALUMINUM

SIZE: 1.25-INCH NOM PIPE SIZE, SCHED 40, OD= 1.66"

INSTALL: INSTALL HANDRAIL 34-INCHES ABOVE STAIR

NOSING

H2 HANDRAIL WALL BRACKET:

MATERIAL:ALUMINUM

SIZE: PER MANUFACTURER STD

C1 SAFETY NOSING (STAIRS S01 AND S08 ONLY)

TYPE: RIBBED BAR ABRASIVE STRIPS

BASE MATL: EXTRUDED ALUMINUM ALLOY 6063 T-5

ABRASIVE:ALUM OXIDE SILICON CARBIDE GRANULE IN A

UV PROTECTED, 2 PART EPOXY, EMBEDED

INTO EXTRUDED CHANNELS

SIZE: 3-INCH WIDE x 3-INCH FROM EACH END

INSTALL: TOP OF ALUM AND CONC TREAD SHALL BE

FLUSH

M1 SEE MECHANICAL DRAWINGS FOR DUCT SIZE

P1 MECH DUCT ENCLOSURE, SEE BASE DET A4/A-502. PTN

TOP TERMINATION SHALL EXTEND 1-INCH INTO CEILING

D1 THIS DIMENSION IS DEPENDANT ON THE LOCATION OF

THE GUARD POST MOUNTING TO CLEAR EXST SLAB

REINFORCING

D2 THIS DIMENSION IS DEPENDANT ON THE LOCATION OF

THE HANDRAIL FROM NOSING TO FACE OF POST

MOUNTING TO CLEAR EXST SLAB REINFORCING. MIN

12-INCHES

D3 3-INCH DIMENSION FROM EDGE OF CONCRETE TO FACE

OF POST. EMBED POST MIN 6" DEEP IN NON-SHRINK

GROUT

R1 REMOVABLE HANDRAIL:

MATERIAL:ALUMINUM

SIZE: 1.25-INCH NOM PIPE SIZE, SCHED 40, OD= 1.66"

INSTALL: PROVIDE SLIDE BOLT TO ENGAGE SLOT CUT IN

POST; SLOT IN H1 POST SHALL BE MACHINED

FROM SOLID ALUM BILLET INFILL

R2 INFILL TO RETAIN SLIDE BOLT:

MATERIAL:ALUMINUM

SIZE: MINIMUM 1.38"Ø x 6" L

INSTALL: MACHINE INFILL MATERIAL TO RECEIVE SLIDE

BOLT (SLOT SIZE: 0.65625" x 0.90625")

R3 SLIDE BOLT (PIECE 1 OF 2):

MATERIAL:ALUMINUM

SIZE: 0.625" W x 0.875" H x 4.375" L FLAT BAR

INSTALL: TAP SLIDE BOLT TO RECEIVE THREADED

SLIDE ROD (PIECE 2 OF 2). APPLY SILICONE

LUBRICANT

R4 SLIDE ROD (PIECE 2 OF 2):

MATERIAL:ALUMINUM

SIZE: 0.375"Ø x 2.50" L

INSTALL: FASTEN TO SLIDE BOLT (PIECE 1 OF 2)

P T

IO

N A

L V

A L

U E

A

IR

P

L A

N S A

N D D

E T

A

IL

S

A-401

BLDG 131

J P

A K

P

K A I

P

K

I, M F

U R

U S

H O

J P

A K s b -1

A -4

.d g n

4 18

C

C

C

D N

D N

DN

4'-0"

8'-6" AT S01

14'-3" AT S08

1T@12")

1'-0"

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:29 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-402.dgn

J U

N E

RTA

URWCWCWC

A B C D

DCBA

TSCD

SD WR

PTD

PARTITION IN

FOREGROUND

LAV

WR

LAV

SH

SHWR

CTRLS

SHWR

HEAD

SHWR

HEAD

SHWR

CTRLS

SH

SHWR PTN

FOREGROUND

A

B

WC

PTD GB1

SND

TTD

WR

WR

PTD

C D

WC LAV

TSCD

SD

MG

PT1

WR GWB

PT1

WR GWB

LAV WC

A

TP3

WC WC

B

TSCD

PT1

WR GWB

LAVWC

C WR

PTD

D

SD

LAV LAV

MG

MG

BA DC

SC

B

PARTITION IN

FOREGROUND

US

PT1

WR GWB

TSCD

TTD

TTD

TP1

TP

CT1

TILE

CT1

TILE

SHWR

HEAD

SHWR

CTRLS

SH

TTD

GB2

PT1

WR GWB

PT1

WR GWB

CT1

TILE

C

BENCH

BENCH

CT1

TILE

CT1

TILE

TP3

PTN

CT1

TILE

CT1

TILE

CT1

TILE

3'-9"

TP2

PTN

TP2

SCR

SC

DET A1/A-406

SHWR PTN SHWR PTN

TPTP

MS

RB1

87"

LIGHT

FIXT

LIGHT

FIXT

87"

A1

TOILET 146 / 103 (SIM)

1/4"=1'-0"

A5

JAN 157 / 114 (SIM)

1/4"=1'-0"

B1

WOMEN SHOWER 156 / 113 (SIM)

1/4"=1'-0"

D1

WOMEN 155 / 112 (SIM)

1/4"=1'-0"

E1

MEN SHOWER 153 / 110 (SIM)

1/4"=1'-0"

F1

MEN 154 / 111 (SIM)

1/4"=1'-0"

M7

M7

W1

W1

W1

W2W2

W1

W2

M7

TILE

OCCURS

BEHIND

LOCKERS

TILE

OCCURS

BEHIND

LOCKERS

C

O U

R S

E S

T Y

P

C

O U

R S

E S

T Y

P

C

O U

R S

E S

T Y

P

M7

W3

W3

EQ EQ

CT

FULL

CT

FULL

EQ EQ

EQEQ

CT

FULL

CNTR ON

FIXT

C

CT4

CG

ELECTRIC

WATER

COOLER

TILE

CT

FULL

EQ EQ

B5

CORR 144 / 101

1/4"=1'-0"

1'-6"

ALIGN

SHEET KEYNOTES

GENERAL SHEET NOTES

CLR

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

F1 FLOOR SHALL SLOPE TO DRAIN, SEE DET A9/A-507

F2 FLOOR SHALL SLOPE TO DRAIN, SEE DET F7/A-507

F3 BENCH, SEE DETAIL E5/A-504

F7 FINISH FLOOR MATERIAL PATTERN DIRECTION

P1 PLUMBING FIXTURE: LAVATORY, WATER CLOSET, URINAL,

OR MOP SINK; SEE SPECIFICATION 22 00 00 PLUMBING

P2 ELECTRIC WATER COOLERS; SEE SEE SPECIFICATION 22

00 00 PLUMBING

T1 WOMEN TOILET ACCESSORIES (TYP): TTD, SND, TSCD

T2 MEN TOILET STALL ACCESSORIES (TYP): TTD, TSCD

T3 PAPER TOWEL DISPENSER (CFCI); WASTE RECEPTACLE

(CFCI)

M5 CORNER GUARD; SEE DET E7/A-504

M6 LOCKERS; SEE SPECIFICATION 10 51 13

M7 UNDER-LAVATORY GUARD

W1 TILE WAINSCOT CAP, SEE DET B7/A-507

W2 TILE CORNER, SEE DET B9/A-507

W3 ACCESS PANEL, SEE DET G7/A-504, SEE SPECIFICATION

08 31 00 FOR MATERIAL

F8

TOILET 146 PLAN

1/4"=1'-0"

/8

4'-5" 4'-6" 1'-6"

/8

2'-8 1/2 "

13'-1 1/2 "

5'-5" 7"

E1/A-402

B1/A-402

A5/A-402

7'-0"7'-9"

1'-5"

5'-5" 7"

2'-0"

E Q

E Q

/8

/8

/8

/8

13'-1 1/2 "

/8

3'-0"3'-0"

1'-6"

A6

CEILING PLAN

1/4"=1'-0"

A8

FLOOR PLAN

1/4"=1'-0"

F1/A-402

D1/A-402

2'-0"

S8

M6

F1

F3

F3

M6

F2

F1

P1

P1

P1

P1

P2 P1S2

T3

T3

T3

T1

T1

T2

S8

1'-4"

A1/A-402

M5

CLR

E Q

E Q

1. SEE SHEET A-001 FOR GENERAL NOTES.

2.SEE SHEET A-101 AND A-104 FOR FLOOR AND CEILING PLAN

SHEET LEGEND, RESPECTIVELY

3.SEE SHEET AF601 FOR INTERIOR FINISH SCHEDULE AND

LEGEND

4.SEE SHEET A-406 FOR TOILET ACCESSORY SCHEDULE AND

MOUNTING HEIGHTS

5.SEE SHEET A-406 FOR TOILET FIXTURE AND ACCESSORY

MOUNTING HEIGHTS.

6.SEE SHEET A-502 FOR PARTITION TYPES

S2 S10 S11

S14

S15

S13

S14

S14

S17

S17

S16

S14

S16

S8W

S18

S1S8 P1

S9

F1

A-504 A7

A-504 A7

5'-1"

P1

E Q

E Q

S8

S5

/8

F7

F7

F7

T3

B5/A-402

FULL CT

CNTR

P T

IO

N A

L V

A L

U E s b -1

A -4

.d g n

A-402

BLDG 131

SCALE: 1/4"=1'-0"

0 4' 8'2'

A

B

C

D

KEY

ELEV

INT

PLAN

NORTH

J P

A K

P

K A I

P

K A I

J P

A K

A N

D I

N T

E R

IO

R E

L E

V A

T

IO

N S

E N

L A

R G

E D R

E S

T R

O O

M F

L O

O R P

L A

N

C E

IL

IN

G P

L A

N

21 21

SHWR

MEN

SHWR

WOMEN

JAN

STOR

MEN

WOMEN

TOILET

CORR

WOMEN

MEN

SHWR

MEN

SHWR

WOMEN

SHEET KEYNOTES

GENERAL SHEET NOTES

K1 BASE AND WALL MILLWORK

A1 REFRIGERATOR (GFGI)

A2 RANGE (GFGI)

A3 RANGE HOOD (CFCI) ABOVE

A4 MICROWAVE (CFCI) ABOVE

F7 FINISH FLOOR MATERIAL PATTERN DIRECTION

P1 SS SINK, FIXTURE, AND GARBAGE DISPOSAL (CFCI)

P2 VANITY AND FIXTURE

P3 WATER CLOSET

P4 TUB

P5 WALL ACCESS PANEL, SEE DET G7/A-504

V1 VANITY AREA, SEE DETAIL A5/A-506: MEDICINE CABINET,

SOAP DISH, TOOTHBRUSH/TUMBLER HOLDER, TOWEL

RING

L1 ELECTRIC LOAD CENTER, SEE ELECTRICAL DWGS

U1 CLOSET SHELF AND ROD ABOVE

M1 FAN COIL UNIT, SEE MECHANICAL DWGS

M2 MECHANICAL SUPPLY AND DUCT, SEE MECHANICAL DWGS

M5 CORNER GUARD, SEE DET E7/A-504

S1 UNIT ROOM SIGNAGE 'A' AND 'B'

C1 EXST EXPOSED CONCRETE (NEW GWB AT THIRD FLOOR

ONLY)

SEE GENERAL SHEET NOTES ON CEILING PLANS FOR EXST

EXPOSED CONCRETE CEILING PREPARATION RQMTS

C2 GYPSUM BOARD CEILING OR SOFFIT

C3 SOFFIT ABOVE

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:31 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-403.dgn

J U

N E

RTA

C1

C2

C1

C2

C2 C2

C1 C1

C2

C2

C1C2

C2

7'-2"

A1E

A-505

A1D

A-505

A1C

A-505

A1B

A-505

A1A

A-505

A1B

A-505

A1A

A-505

A1E

A-505

A1D

A-505

A1C

A-505

A1B

A-505

A1B

A-505

7'-2"

1.SEE SHEET A-001 FOR GENERAL NOTES.

2.SEE SHEET A-101 AND A-104 FOR FLOOR AND CEILING PLAN

SHEET LEGEND, RESPECTIVELY

3.SEE SHEET AF601 FOR ROOM FINISH SCHEDULE AND

LEGEND

4.SEE SHEET A-404 FOR UNIT INTERIOR ELEVATIONS

5.SEE SHEET A-502 FOR PARTITION TYPES

6.FIXTURES AND ACCESSORIES ARE SHOWN IN PLAN OR

ELEVATION AND APPLY TO SIMILAR ROOMS (MIRRORED

CONDITIONS) THAT ARE NOT OTHERWISE NOTED.

7.PROVIDE CONCEALED SOLID BLOCKING FOR ALL WALL

MOUNTED ACCESSORIES. SEE DET G9/A-504

A1A

A-505

A1A

A-505

C1

C2

C2

C1

C1

SIM

1'-5"

3'-8"

1'-5"

1'-5"

2'-7 1/8 " 2'-2 1/8 "

2'-1 3/4 "

2'-1"

2'-9 3/4 "

3'-11"

A1

CEILING PLAN - TYPICAL UNIT

1/4"=1'-0"

A6

FLOOR PLAN - TYPICAL UNIT

1/4"=1'-0"

5'-4"

2'-1 5/8 "1'-6"

5'-7"

1'-7" 5'-4"

5'-7"

5'-7" 5'-7"3"

3" 3"

34'-0"

4'-0" 4'-0"4'-0"4'-0"

34'-0"

4'-0"4'-0" 4'-0"4'-0"

6 6

S1

A1

K1

P1

M1

S4

S3

S3

S2

M2

S3

3'-10"

S3

S3

3'-10"

U4 U4

U4 U4

U

U

U

U

U

U

U2

U2

S5

M2

A1

K1

P1

A2

S3 S1 S3

M1

S3S3 S3S3

S5

A7/A-506

A7/A-506

F1/A-404

C3

C3

S1

S1

C3 C3

S2 S2

S2

S3

S2

U1

S4

S4

S7

S15

S15

S7

S2

S4

M1

C3

M1

C1

S19

S19

M1

M1

M2

M2

A2 A3

A4

V1

A3

A4

S3 S3C3

C3

3" 3"

11 3/4 "

3" 3"

3"3"

P4

F1/A-404

P3

P3

P4

P5

P5

5 5/8 "

1'-8"

6"

5 5/8 "

1'-0"

6" 5 5/8 " 1'-8" 6"

6" 12"

5 5/8 "

4"

5 5/8 " 1'-8" 6" 4"

3"

6"

12" 5 5/8 "

C13

L1

L1

E1/A-404 E1/A-404

E1/A-404 E1/A-404

S2 S2

S2 S2

S2S2

S20

S20

M5

M5 M5

M5 M5

3"

M5

M5

M5

P2 V1

P2

M5

S20

S20

S20

S20

C1

C1

C1

C1

U1

U1 U1

C3

C3 C3

C O

N C R

O C

O N

C R

O

M5

S4 S5

F4/A-404F4/A-404

F4/A-404 F4/A-404

F7

F7

F7

F7

P T

IO

N A

L V

A L

U E s b -1

A -4

.d

SCALE: 1/4"=1'-0"

0 4' 8'2'

A

B

C

D

KEY

ELEV

INT

PLAN

NORTH

A-403

E N

L A

R G

E D U

N

IT

F

L O

O R P

L A

N

BLDG 131

A N

D C

E

IL

IN

G P

L A

N

J P

A K

P

K A I

J P

A K

P

K A I

GRID GRID

GRID

GRID

GRID

GRID

GRID GRID

GRID

GRID

GRID

GRID

BATH

U108

LIVING

U108

LIVING

U107

KITCHEN

U107

KITCHEN

U108

CLO B

U108

CLO A

U108

CLO A

U107

CLO B

U107

BATH

U107

BEDROOM A

U107

BEDROOM B

U107

BEDROOM B

U108

BEDROOM A

U108

KITCHEN

U107

LIVING

U107

KITCHEN

U108

LIVING

U108

CORR

BEDROOM A

U107

BEDROOM B

U107

CLO B

U107

CLO A

U107

BEDROOM B

U108

BEDROOM A

U108

BATH

U108

BATH

U107

CLO A

U108

CLO B

U108

SHEET KEYNOTES

GENERAL SHEET NOTES

K1 BASE AND WALL MILLWORK

A1 REFRIGERATOR (GFCI)

P1 SS SINK , FIXTURE, AND GARBAGE DISPOSAL (CFCI)

M2 MECHANICAL DUCT, SEE MECHANICAL DWGS

L1 SS FOLDING TABLE (CFCI)

L2 SS GARMENT RACK (CFCI)

W4 TILE TUB JOINT AT MASONRY WALL, SEE DET D7/A-507

W5 TILE WALL FIN EDGE, SEE DET D9/A-507

W6 ALIGN FACE OF CONC WITH FACE OF EXST MASONRY

T1 TR CABLE LADDER, SEE TELECOMMUNICATIONS DWGS

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:36 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-404.dgn

J U

N E

RTA

C D

PT1

IR GWB

CLOSET

SHELF

A-506

G1

D

EQEQ

IR GWB

PT1

RB1

BASE AS

SCHED

B

IR GWB

PT1

RB1

BASE AS

SCHED

ROBE

HOOK at

60" AFF

LC

L1

L2

B (C AT 205 & 305)

4'-0" (205 & 305)

5'-2"

MIRROR

GLASS

(16"x70") W/

SS FRAME

A

WC TUBTUB

TB

TPH B C

CT1

TILE

PT1

WR GWB

TP

SCRC

SC

CT3

WC

D

TUB

SHWR

HEAD

"3

PT1

WR GWB

MECH

REGISTER

2"

CT1

TILE

1'-6"

ACCESS

PNL DET

G7/A-504

BULLNOSE

TRIM BASE

3"x12"

BULLNOSE

TRIM BASE

3"x12"

CT3

DRYER

(GFGI)

MG

E1

BEDROOM B U107 (U108 SIM)

1/4"=1'-0"

E4

LAUNDRY 131 (205 & 305 SIM)

1/4"=1'-0"

F1

BATH U107 (U108 SIM)

1/4"=1'-0"

F4

CLOSET B U107 (U108 SIM)

1/4"=1'-0"

W4

SHWR

NICHE

DET

A5/A-507

W5

WALL

TRIM

EQ EQ

CG

JOINT

D1

MAIL ACCESS 129C

1/4"=1'-0"

RB1

BASE AS

SCHED

IR GWB

PT1

EQ EQ

C

RB1

IR GWB

PT1

PT1

CMU

A-504 A-504

E9 A9

F7

UNIT CHASE

1/4"=1'-0"

A1

K1

P1

M2

1.SEE SHEET A-001 FOR GENERAL NOTES.

2.SEE SHEET A-101 FOR FLOOR PLAN SHEET LEGEND

3.SEE SHEET AF601 FOR INTERIOR FINISH SCHEDULE AND

LEGEND

4.SEE SHEET A-406 FOR TOILET ACCESSORY SCHEDULE AND

MOUNTING HEIGHTS

5.SEE SHEET A-502 FOR PARTITION TYPES

6.FIXTURES AND ACCESSORIES ARE SHOWN IN PLAN OR

ELEVATION AND APPLY TO SIMILAR ROOMS (MIRRORED

CONDITIONS) THAT ARE NOT OTHERWISE NOTED

7.PROVIDE CONCEALED SOLID BLOCKING FOR ALL WALL

MOUNTED ACCESSORIES, SEE DET G9/A-504

S20

M2

S5C1

S20

M2

C1

1'-2"6"

C1

S4

6"6" 4" 3" 6"6"

W6

M2 A1

P1

K1

S3

S20

S5

T1

E7 CHASE at EF/TR (FLR 1-3) 1/4"=1'-0"

C1

A L

IG

N

F O

S

1'-3"

6" 4"

P T

IO

N A

L V

A L

U E s b -1

A -4

.d

A-404

BLDG 131

J P

A K

P

K A I

P

K A I

J P

A K

IN

T

E R

IO

R E

L E

V A

T

IO

N S

SCALE: 1/4"=1'-0"

0 4' 8'2'

6 16

C

D

STAIR

S04

STAIR

S05

UNIT

UNIT

201 209

301 309

UNIT

EF

TR

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:37 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-406.dgn

J U

N E

RTA

M A

X

M A

X

9"

" 5

"4

M A

X

T O F

IN

F

L R

S

P O

U T H

T

M A

X

TYPICAL

LAVATORY

ELEC WATER

COOLER

SHOWER

CONTROLS

PAPER TOWEL DISPENSER

& WASTE RECEPTACLE

BOTTLE

FILLING

STATION

C L

C L

C L

C L

BOTTOM OF

REFLECTIVE

EDGE

SHOWER HEAD

SHOWER CONTROLS

SOAP HOLDER

UTILITY SHELF WITH

MOP/BROOM HOLDERS

HEIGHT TO

DISPENSER

HANDLE

SCALE: 1/2"=1'-0"

2' 4'0 1'

SHOWER ENCLOSURE

MG

SD

WR

PTD

TP

SH

US

SHOWER

HEAD

TOWEL PIN

A1 1/2"=1'-0"

TYPICAL FIXTURE AND ACCESSORY MOUNTING HEIGHTS

STILE

CEILING

S H

W R D

O O

R

TP2

URINAL

EQ EQ

TP1

SC

PTD

SCR

US

SH

SND

SD

WR

GB-1

TP

TTD

TP1

GB-2

TSCD

SHOWER CURTAIN, VINYL

PAPER TOWEL DISPENSER, SURFACE MOUNTED

SOAP HOLDER

SANITARY NAPKIN DISPOSAL

TOWEL PIN, DOUBLE HOOK, CONCEALED MOUNTING

TOILET ENCLOSURE, SEE SHT AF601

TOILET TISSUE DISPENSER, SURFACE MOUNTED

SOAP DISPENSER, LAVATORY MOUNTED

TOILET SEAT COVER DISPENSER, SURFACE MOUNTED

WASTE RECEPTACLE, SURFACED MOUNTED

TOILET ACCESSORY SCHEDULE

CODE DESCRIPTION

1-1/2" OD GRAB BAR, 42" L., CONCEALED MOUNTING

1-1/2" OD GRAB BAR, 36" L., CONCEALED MOUNTING

GENERAL SHEET NOTES

TP2 SHOWER ENCLOSURE, SEE SHT AF601

MG

TP3

MIN

3'-1"

MIN

3'-0"

CEILING

TP3

MIN

2'-0"

MIN

2'-0"

MIN

1'-0"

1'-6"

MAX

1'-0"

ACCESSIBLE

WATER CLOSET

ACCESSIBLE

WATER CLOSET

TYPICAL WATER CLOSET TYPICAL WATER CLOSET

C L

C L

GB-2

TSCD

GB-1

TTD

SND

9"

EQ

PER PLAN

EQ

C L

TP1

9"

(PER

PLAN)

5'-1"

CLEAR STILE

CEILING

TP1

D O

O R

2'-1"

SND

TSCD

(PER

PLAN)

TTD

ALIGN

ROOM ENTRY SCREEN

ROOM ENTRY SCREEN, SEE SHT AF601

SS POST

SS POST

CAP (TYP)

SHOWER CURTAIN ROD, HEAVY DUTY, SS, 84" AFF

SS UTILITY SHELF W/ MOP/BROOM HOLDERS &

HOOKS, 8" X 34" W., SURFACE MOUNTED

MIRROR GLASS (18" X 30"), WITH SS FRAME

SS POST

SS POST CAP

T & B (TYP)

A L

IG

P T

IO

N A

L V

A L

U E s b -1

A -4

.d

A-406

O

U N

T

IN

G H

E

IG

H T S

T Y

P

IC

A L F

IX

T U

R E A

N D A

C C

E S

S O

R Y

BLDG 131

GENERAL SHEET NOTES

J P

A K

P

K A I

J P

A K

P

K

I, G

T

O Y

A M

A

DETAILED ACCESSORY DESCRIPTION

SEE SPECIFICATION 10 28 13 TOILET ACCESSORIES FOR 3.

SCREEN PARTITIONS. STABILIZE PATITION ASSEMBLY

TO ENABLE ANCHORING OF TOILET, SHOWER, AND ENTRY

PROVIDE CONCEALED BLOCKING IN SUSPENDED CEILING 2.

ACCESSORIES, SEE DET G9/A-504

ENABLE ANCHORING OF ALL WALL MOUNTED TOILET

PROVIDE CONCEALED BLOCKING IN PARTITION TYPES TO 1.

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:39 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-501.dgn

J U

N E

RTA

GUTTEREXPANSION

CAP

GUTTER

GUTTER LAP

DETAIL

SL DN

ISOMETRIC

SECTION A-A

NTS

A

A

HALF FULL SIZE3"=1'-0"

3 1/4"

13/16" 13/16"

5/8"

4 1/2 "

2 1/2 "

/2

FACE OF EIFS

OR EFS

DASHED LINE

INDICATES

HORIZ EIFS

BAND WHERE

OCCURS

WALL OR

COLUMN

3/16" DIA SS

HEX BOLT &

NUT W/ LOCK

WASHER

LEAD EXP

SHIELD

( PROVIDE

SPACER

SLEEVE AT

INSULATION)

3 1/2 "

C OF VENTL

EQ EQ

BASE SECURED

W/ SELF

TAPPING

GASKET

SCREWS SET

IN SEALANT

EPDM

RUBBER

VENT THRU

ROOF (SEE

MECH DWGS

FOR SIZE)

MET ROOF

PANEL

CENTER VENT

BETWEEN

STANDING

SEAMS

GUTTER

ENDS

1/8" THK X

1 1/2" WIDE

SS WALL

BRACKET

PRE-FINISHED

MET GUTTER

EXST EIFS

M

IN

PAINT VENT TO

MATCH MET

ROOF PANEL

COLOR

1/2" SS WIRE

MESH CAP

ANCHORED

W/ SS BAND

CLAMP

/2

/2

DASHED LINE

REMOVE EXST

GUTTER STRAP

EXST ROOF

SYSTEM

DOWNSPOUT

DET C9/A-501

16GA x 1 1/2"W

PRE-FINISHED

MET STRAP

OVER DS

NOTE:

GUTTER EXPANSION JOINT / HIGH POINT

LOCATIONS SHOWN ON SHEET A-201.

DRAIN

SL TO

DRAIN

SL TO

1/4" DIA X

2 1/2" LONG

SS LAG BOLT

W/ WASHER

EXST VENT

PENETRATION

VERIFY

CRIMP SHT

MET FLASH

OVER EXST

STANDING

SEAM

DOUBLE ROW

HIGH PERF

ROOFING

SEALANT

SHEET METAL

COVER FINISH

TO MATCH

SSSR

EXST SSSR

STANDING

SEAM

SEALANT

ALONG

LEADING EDGE

OF COVER

1/8" THK x 1"

WIDE MET

BRACKET AT

30" OC

1/8" THK x 1"

WIDE MET

GUTTER STRAP

AT 30" OC

/4

COPPER WIRE

STRAINER

METAL ANGLE

1" x 1" x 3/16"

1"1"

9"

0 2" 4" 0 2" 4"

0 2" 4"

0 2" 4"

SEE SHT A-103 AND A-108 FOR LOCATIONS

SEE SHT A-103 AND A-108 FOR LOCATIONS

DIRECTION OF

ROOF SLOPE

S L

0 2" 4"

SHT MET

FLASHING

7"

/2

EXST SSSR ON

EXST PURLIN

NEW OR

EXISTING EIFS

NEW OR EXST

CONC OR CMU

MET TRACK

SEE STRUCT

DWGS

E9

GUTTER EXP JT DET

SCALE AS NOTED

E7

GUTTER DETAIL

3"=1'-0"

C7

VENT THRU ROOF DET

NTS

C9

DOWNSPOUT DET

3"=1'-0"

A9

ROOF PANEL COVER

3"=1'-0"

A7

RAKE DETAIL

3"=1'-0"

2"8"2"

1'-0" S

L /2

CONC SPLASH BLOCK

A5

NTS PROVIDE SPLASH BLOCK AT ALL DOWNSPOUTS

3"6"3"

1 1/2 "

(4" THK SIDES)

CONCRETE

PRECAST

BLDG

SIZE

W L H

131 1 10'-8" 17'-4" 8'-0"

131 2 10'-8" 17'-4" 8'-0"

ENCL

131 1 10'-8" 17'-4" 8'-0"

131 2 10'-8" 17'-4" 8'-0"

WxL

EXST SITE ENCL

C5

NTS

EXISTING SITE ENCLOSURES

FORREST

BROWN (3'-0"

OR NEAREST

COURSE JT)

NOTES:

1.SEE CIVIL SHT CS101 FOR EXST SITE ENCL LOCATIONS

2.PROVIDE NEW EXTERIOR PAINT COATING FOR ALL EXST SITE ENCLOSURES

3.NEW PAINT COATING SHALL BE APPLIED TO ALL EXST SURFACES

4.SEE SHEET A-201 EXTERIOR COLOR LEGEND FOR FINISH CODE DESCRIPTION

5.PROVIDE CONTINUOUS HORIZONTAL WALL MOUNTED GUARD AT INTERIOR OF

ENCLOSURE. MOUNTING HEIGHT SHALL ALIGN WITH CONTAINER PROTRUSION

PT4

P T

IO

N A

L V

A L

U E s b -1

A -5

.d

A-501

P

K A I

R O

O F A

N D M

IS

C

E L L

A N

E O

U

D

T A

IL

S

BLDG 131

B

C H

U N

B

C H

U N

IF

B3

B1

B2 T1B2T1

B1

B3

T1B2

B3

E1

E1

P1P1

P1

P1

B4

P8

P7

D1

P7

B4

P1

D1 B3

B1

P1

E1

P1P1

P6 P6

P2

R4 R1

P2P5A P5B

P5 P5

R1

P5A

T1B2

E1

G6

W2

S2

W3

W1 W1

T1B2

B3

P1

E1

B3

P1

E1

G3G2G3 OR

PER FIN

SCHED

G3

PER FIN

SCHED

CT2

FULL

HGT

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:43 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-502.dgn

J U

N E

RTA

GENERAL SHEET NOTES

SHEET KEYNOTES

G1

G1

S1

A1

S1

G2

G2

S1

A1

E1

G2

S3

A2

3"

S2

S3

S4

S7 G2

S1

S4

S8

G3

TYP (UON)

E1

G3

S2

4" TYP (UON)

S5

G2

G4

S1

A1

SF

S11

G2

G3

S1

A1

SF

S10

S14

S9

CT2

G4

G4

S1

A1

S13

CT1

G2

G4

S1

A1

S15

CT2

G4

G4

S1

A1

CT1

CT2

CT1

S16 G3

G4

S1

A1

CT2

G2

G4

S4

A1

S18

E1

G4

S4

7" TYP (UON)

S17

M1

C1

M1

C1

CT1

PTN DETAILS:

TOP: D2/A-502

BOT: A2/A-502

PTN DETAILS:

TOP: D2/A-502

BOT: A2/A-502

MIN STC 45

MIN STC 45

1-HR

UL NO. U419

MIN STC 45

MIN STC 45

MIN STC 45

MIN STC 45

PTN DETAILS:

TOP: D1/A-502

BOT: A1/A-502

S6

: S7

A1

S7W

: S7W

E1

G2

S2

4" TYP (UON)

E1

G2

S5

G2

G2

S1

A1

SF

MIN STC 45

G2

G4

S1

A1

CT1

MIN STC 45

1-HR

UL NO. U419

PTN DETAILS:

TOP: D2/ - (SIM)

BOT: A2/ - (SIM)

PTN DETAILS:

TOP: F1, F2/ -

BOT: A1/A-502

PTN DETAILS:

TOP: F1, F2/ -

BOT: A1/A-502

PTN DETAILS:

TOP: F1, F2/ -

BOT: A1/A-502

PTN DETAILS:

TOP: F1, F2/ -

BOT: C1/A-502

B O T

A 1/

A -5

T O P F 1, F

2/

P T N D

E

T

A

IL

S

PTN DETAILS:

TOP: F1, F2/ -

BOT: C1/A-502

PTN DETAILS:

TOP: F1, F2/ -

BOT: C2/A-502

PTN DETAILS:

TOP: F1, F2/ -

BOT: C1/A-502

PTN DETAILS:

TOP: F1, F2/ -

BOT: C2/A-502

PTN DETAILS:

TOP: F1, F2/ -

BOT: C1/A-502

CT1CT3

CT3

CT3

CT3

CT3

CT3

S8W

CT2

: S8

: S8W

G3

G3

S1

A1

PTN DETAILS:

TOP: F1, F2/ -

BOT: A1/A-502

S19

PTN DETAILS:

TOP: F1, F2, F4/-

BOT: A1/A-502

PTN DETAILS:

TOP: D2, D4/ -

BOT: A2/A-502

PTN DETAILS:

TOP: F1, F2, F4/ -

BOT: C1/A-502

PTN DETAILS:

TOP: F1, F2, D4/-

BOT: A1/A-502

SEE

DISCIPLINE

DWGS FOR SIZE

SEE INTERIOR

FINISH SCHED

FOR FINISH

SEE INTERIOR

FINISH SCHED

FOR FINISH

S20 G2

S6

1-HR

UL NO. U415

G5

PTN DETAILS:

TOP: D1/A-502

BOT: D1/- (SIM)

: S8WG3

PTN DETAILS:

TOP: F1, F2, F4/-

BOT: C1/A-502

PTN DETAILS:

BOT: C2/A-502

SIM

E1 EXST OR NEW MASONRY OR CONC

G1 5/8-INCH GYPSUM WALL BD

G2 5/8-INCH TYPE 'X' IMPACT RESISTANT GYPSUM BD

G3 5/8-INCH TYPE 'X' WATER-RESISTANT GYPSUM BD

G4 5/8-INCH TYPE 'X' GLASS MAT WATER-RESISTANT GYPSUM

TILE BACKING BD

G5 1-INCH GYPSUM LINER PANEL

G6 5/8-INCH GLASS MAT EXTERIOR GYPSUM SHEATHING BD

S1 362S162-54 METAL STUD @ 16" OC

S2 362S125-43 METAL STUD @ 16" OC

S3 250S125-43 METAL STUD @ 16" OC

S4 600S125-43 METAL STUD @ 16" OC

S5 7/8" HAT CHNL - HORIZONTAL @ 16" OC

S6 2 1/2" C-H STUD 20GA @ 24" OC

A1 4" SOUND ATTENUATION BATT

A2 3" SOUND ATTENUATION BATT

SF 18 GA EXPANDED STEEL FABRIC

M1 CONCRETE MASONRY UNIT, SEE PLANS FOR SIZE

C1 CONCRETE WALL OR COLUMN

CT1 CERAMIC TILE - WAINSCOT

CT2 CERAMIC TILE - FULL HEIGHT; FLOOR TO CEILING

CT3 CERAMIC TILE TRIM DET B7/A-507

W1 EXTEND MEMBRANE 4" ABOVE WAINSCOT AT SHOWERS

ONLY

W2 REINF CONC CURB, SEE STRUCTURAL DRAWINGS

W3 EXTERIOR FINISH SYSTEM, (EFS-2)

B1 SEE INTERIOR FINISH SCHEDULE FOR BASE AND FLOOR

MATERIAL

B2 ACOUSTIC SEALANT: SET STUD TRACK IN TWO ROWS OF

CONT ACOUSTIC SEALANT

B3 ACOUSTIC SEALANT: CONTINUOUS ACOUSTIC SEALANT

BENEATH GYPSUM BOARD SHEATHING, BOTH SIDES

B4 CERAMIC TILE FINISH, WITH THINSET ON REINFORCE

MORTAR BED. SLOPE TO FLOOR DRAIN. TILE

INSTALLATION METHOD TCNA F215

T1 TOP AND BOTTOM TRACK SHALL MATCH THE SIZE AND

GAUGE OF THE CORRESPONDING PARTITION METAL STUD.

R1 EXST STEEL STANDING SEAM ROOF

R2 EXST ROOF PURLIN; VERIFY SPAN BETWEEN PURLINS

R3 R-30 FIBERGLASS FOIL-FACED THERMAL BATT INSULATION

WITH METAL RETAINING STRAPS

R4 SOUND ANTTENUATION BATT; FILL GAP BETWEEN ROOF

PANEL AND TOP OF BOX BEAM

P1 PARTITION AS SCHEDULE

P2 DOUBLE 362S162-54 METAL STUD

P3 362S162-54 METAL STUD AT 24 -INCHES OC

P4 MET STUD TOP TRACK FORMS BOX BEAM, CONNECTS

STUDS TOGETHER

P5 ANCHOR STUD BOX BEAM TO TOP OF PARTITION

P5A 14 GA METAL ANGLE; ANCHOR TO STUD BOX BEAM AND

TO PURLIN

P5B 14 GA METAL ANGLE; USE TO CONNECT PARALLEL AND

PERPENDICULAR BOX BEAMS TO EACH OTHER

P6 14 GA VERTICAL SLIDE CLIP AT EACH STUD

P7 ANCHOR STUD TO STRUCTURE AT TOP AND MID-POINT

P8 SUSPENDED CEILING AS SCHEDULED

D1 WALL & FLOOR TILE COND AT DEPRESSED SLAB, SEE DET

A7/A-507

P1

C1

G2

S1

A1

SF

PTN DETAILS:

TOP: F1, F2/ -

BOT: A1/A-502

S22

1.SEE SHEET A-101, A-402, AND A-403 FOR LOCATIONS OF

PARTITION TYPES.

2. INSTALL 5/8" 'IMPACT RESISTANT' GWB, FROM FLOOR TO

8'-0" ABOVE FINISH FLOOR AT MAIN CIRCULATION AREAS:

SEE INTERIOR FINISH SCHEDULE.

3. INSTALL 5/8" GLASS MAT WATER RESISTANT GYPSUM TILE

BACKING BOARD ON ALL WALLS SCHEDULED TO RECEIVE

CERAMIC TILE FINISH. COORDINATE LOCATION OF

CERAMIC TILE WALL FINISH/ WAINSCOT WITH INTERIOR

FINISH SCHEDULE ON SHEET AF601. PROVIDE 5/8" 'WATER

RESISTANT' GWB ABOVE CERAMIC TILE WAINSCOT.

4.UNLESS OTHERWISE NOTED, PARTITION STUD GAUGE TO

BE DESIGNED TO AN L/240 DEFLECTION (FOR PARTITION

ASSEMBLY) AS REQUIRED BY CODE.

5.ON PARTITIONS TO RECEIVE TILE FINISH, PARTITION STUD

GAGE TO BE DESIGNED TO L/360 DEFLECTION OR LESS

(FOR PARTITION ASSEMBLY) AS RECOMMENDED BY T.C.A.

6.OFFSET ALL ELECTRICAL AND TELECOM J-BOXES LOCATED

ON OPPOSITE SIDES OF A PARTITION A MINIMUM OF 24" OC

AND EXTEND INSULATION IF PARTITION TYPE CONTAINS

INSULATION AROUND BOXES. ACOUSTIC SEAL ALL

ELECTRICAL AND DATA J-BOXES RECESSED IN PARTITIONS.

7. INSTALL GWB CONTROL JOINT ON CONTINUOUS

PARTITIONS IN EXCESS OF 30'-0" AT A MAXIMUM

INCREMENT OF 20'-0" OC. IF MULTIPLE CONTROL JOINTS

ARE REQUIRED, THEN EQUALLY SPACE JOINTS ALONG

ENTIRE PARTITION.

8.PROVIDE (2) POWDER ACTUATED FASTENERS (ALLOWABLE

SHEAR CAPACITY = 420 LBS/FASTENER MIN) THROUGH THE

CFS TRACK AT EACH STUD. INSTALL PER

MANUFACTURER'S REQUIREMENTS.

9.POWDER ACTUATED FASTENERS SHALL BE INSTALLED

AFTER CONC HAS CURED FOR 7 DAYS OR AFTER CONC HAS

REACHED A MIN COMPRESSIVE STRENGTH OF 2,000 PSI.

0 8"4"0 8"4"

A1 0 8"4"

EXST 4'-

0" O

C

0 8"4"

0 8"4"

0 8"4"

R2

R3R2

BEYOND

R3 R2

R4

P3

0 8"4"

SEE PLAN

0 8"4"0 8"4"

0 8"4"0 8"4"

PTN TERM at BOT 1 1/2"=1'-0"

A2 PTN TERM at BOT 1 1/2"=1'-0"

A4 PTN TERM at BOT 1 1/2"=1'-0"

C2 PTN TERM at BOT 1 1/2"=1'-0"

C1 PTN TERM at BOT 1 1/2"=1'-0"

D1 PTN ANCHOR at TOP 1 1/2"=1'-0"

D2 PTN ANCHOR at TOP 1 1/2"=1'-0"

D4

CONCRETE COND

PTN ANCHOR at

1 1/2"=1'-0"

F1

PERP TO PURLIN

PTN ANCHOR at TOP

1 1/2"=1'-0" F2

PARALLEL TO PURLIN

PTN ANCHOR at TOP

1 1/2"=1'-0" F4

CONCRETE COND

PTN ANCHOR at

1 1/2"=1'-0"

P T

IO

N A

L V

A L

U E s b -1

A -5

.d

A-502

P

K A I

:3

:4

P

M

A N

S I-

D

P E

N T

B L

P L T

D R

V

B W a n d

G ra y s c a le

P e n .t b l p o h -n e ta p p \c a d \m is c \M

S -W

O R

K S

P A

C E \S ta n d a rd s \p lt c fg \P

D F -A

E C v .p lt c fg

S A

V E

D B

Y

/1

/2

M O

D E

L N

A M

E c p w -w o rk \p o h -1 \j e c p m k \d

\1 s b -1

A -5

.d g n

P A

R T

IT

IO

N T

Y P

E S A

N D D

E T

A

IL

S

BLDG 131

B

C H

U N

P

K A I

B

C H

U

SHAFT

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:47 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-504.dgn

J U

N E

RTA

EXST SOFFIT

FRAMING

ADD SOFFIT

FRAMING AS

NECESSARY

LINE OF EXST

SOFFIT FRMG

EXST 5/8" GYP

SHEATHING 5/8" GMGS

CMU OR CONC

EXST CMU

0 2" 4"

0 2" 4"

NEW

NEW INSUL TO

MATCH EXST

THICKNESS

N E

W

*NOTE

*NOTE

EXST INSUL

EXST INSUL

NEW

INSULATION TO

MATCH EXST

THICKNESS

EXST CONC

WHERE

OCCURS

E X

S T

REINF MESH

C O

N C

S O

N R

Y

REINF MESH

*NOTE:

APPLY EFS FINISH COAT OVER NEW INSULATION AND EXISTING EFS

FINISH TO CONCEAL JOINTS AND PROVIDE FLUSH SURFACE. TAPER

EXST INSULATION EDGE TO FACILITATE FLUSH TRANSITION WITH NEW

EXST AND NEW INSULATION INTERSECTION SHALL NOT ALIGN WITH

EXST TRANSITION BETWEEN NEW AND EXST WALL MATERIAL

*NOTE:

APPLY EFS FINISH COAT OVER NEW INSULATION AND EXISTING EFS

FINISH TO CONCEAL JOINTS AND PROVIDE FLUSH SURFACE. TAPER

EXST INSULATION EDGE TO FACILITATE FLUSH TRANSITION WITH NEW

PROVIDE RIGID MET SUPPORT AT INTERSECTION OF EXST AND NEW

MATERIAL TO ENABLE FLUSH ALIGNMENT OF SUBSTRATE MATERIALS

AND EFS FINISH

C3

HORIZ EFS TRANSITION DET

3"-1'-0"

A3

VERT EFS TRANSITION DET

3"=1'-0"

4"

362S125-33

MET STUD

@ 16" OC

FINISH FLOOR

& BASE

WASHER

BOX

SEALANT

WINDOW

FRAME

EIFS ON CMU

OR CONC

GLAZING IR GYP BD

BEYOND

1/2 "

WASHER /

DRYER

SILL ROH 1/8" R EDGES

IMPACT

RESISTANT

TYPE X GYP BD

SOLID SURFACE

(SS1)

0 8"4"

TYP WASHER/DRYER CHASE

A5

1 1/2"=1'-0"

1/2 "

LAVATORY

MIRROR

SEALANT

FINISH FLOOR

PROVIDE

BLKG TO

SUPPORT

WALL MTD

LAV

6" MAX

8" MIN

M A

X

362S125-43

MET STUD

@ 16" OC

M

IN

S

ID

E S

/2 T

Y P

PARTITION

AS SCHED

1/8" R EDGES

MIRROR

REFLECTIVE

EDGE +40" AFF

7"

0 8"4"

1/2" PLYWD

TREATED PAINT

EDGES (PT1)

5/8" TYPE 'X'

GLASS MAT

WR GYP TILE

BACKING BD

CT

5/8" TYPE 'X' GLASS

MAT WR GYP TILE

BACKING BD

SOLID SURFACE

(SS1)

TYP LAVATORY DETAIL

A7

1 1/2"=1'-0"

PT1

ALL WD

EDGES

CT WALL

FIN

PARTITION

AS SCHED

SEE INTERIOR ELEVATION FOR

ADDITIONAL INFORMATION

TWO UNITS - 32 DOORS EACH

MAILBOXES

BACKLOADED

FRAME RO W/

METAL/WOOD

STUDS

0 8"4"

MAIL ACCESS DETAIL

A9

1 1/2"=1'-0"

MAILROOMMAIL ACCESS

FF

2 4 2 4

2 4

CLG AS

SCHED

3/4" PLYWD

PLATFORM

1x3 TRIM 3

SIDES, W/1/8"R

(PAINT PT-1)

UNDERSIDE OF

EXST CONC

FLOOR

18GA

EXPANDED

STEEL FABRIC

18GA

EXPANDED

STEEL FABRIC

L TRIM W/

SEALANT &

BACKER ROD,

3 SIDES

FLR & BASE

AS SCHED

FULL SURROUND

METAL TRIM PER

MAILBOX MANUF

08"

EFS-2

M

O D

U L E

S

2'

4 MODULES

ALIGN

SURFACE MOUNTED

CELL PHONE LOCKERS

CELL PHONE LOCKER

E1

3/8"=1'-0"

6.5"Wx5.25"Hx5"D)

(QTY: 20; SIZE:

LOCKER

CELL PHONE

SURFACE MTD

1"

NOTE:

SEE FLOOR PLAN FOR LOCATIONS IN ARMS ROOM.

FRONT SIDE

1"3

2 3/4 "

FLOOR LINE

1/4 "R

O F W

A L L

T O F

A C

E

6"

OF WALL

TO FACE

0 2"1"

3/8" Ø STL ROD

(HOT-DIPPED

GALV)

PLAN

QTY: 8 PER ARMS VAULT

E3

FLOOR ANCHOR DETAIL

6"=1'-0"

2"

1"

HDWD (WD1)

BENCH, 1/4" R

ALL EDGES &

CORNERS

3"

2'-0"

0 1'6" E5

BENCH DETAIL

1"=1'-0"

WALL

1/4" SS PL W/

2 EA 3/8" DIA

SS LAG BOLTS

1 1/2" SQ SS

TUBE LEGS

1/8" x 3" SS

PLATE

1 1/2" SQ SS

TUBE LEGS

1/4" SS PL ON

RUBBER PAD

W/ 3/8" DIA SS

EXP BOLT

NOTES:

1.WELD AND GRIND SMOOTH ALL JOINTS

2.PROVIDE RUBBER SPACERS BENEATH EACH LEG PLATE TO PROVIDE

LEVEL BENCH SURFACE DUE TO FLOOR SLOPE. (MIN 1/4" THK)

METAL

STUDS

RESIL BASE IS

CONT AROUND

CORNER (TYP)

CONT VINYL

RETAINER

2"

0 2"1"

HIGH IMPACT

VINYL

ACRYLIC

EXTRUSION

1/4" RADIUS

E7

CORNER GUARD DETAIL

6"=1'-0"

NOTE: CORNER GUARD SHALL EXTEND FROM

FLOOR TO CEILING. RESILIENT BASE SHALL

TERMINATE INTO CORNER GUARD

DOOR AS

SCHED

1'-0"

PARTITION

AS SCHED

2 4

2 4

3/4 "

3'-0" AFF

METAL STUD

0 8"4"

MAILROOM COUNTER

E9

1 1/2"=1'-0"

COUNTER

BELOW

DOOR FRAME

PARTITION

AS SCHED

TRIM BELOW

1x4 TRIM

BOTH SIDES

(PAINT PT-1)

PARTIAL PLAN

COUNTER

EXTENSION

1x TRIM ALL

SIDES. 1/8" R

ALL EDGES

1x TRIM ALL

SIDES. 1/8" R

ALL EDGES

(PAINT PT-1)

2 LAYERS 3/4"

PRE-FINISHED

LAMINATE

PLYWD PANEL

(COLOR-WHITE)

1" 1" 1" 1"

FRAME OPENINGMET STUD PER

PTN TYPE

GYP BD PER

PTN TYPE

EXST CHASE

0 8"4"0 8"4"

8"

OPENING

FRAME

EXST 8" CMU

REFER TO PLUMBING DWGS FOR

LOCATION

0 8"4"

/8

PARTITION AS

SCHED

EXST WINDOW

EXST STL

COLUMN TO

REMAIN

SILL BELOW, SEE

DET B5/A-602

SEALANT &

BACKER ROD EXST MASONRY

TO REMAIN

CONC REINF,

SEE STRUCT

DWGS

FLUSH FIRE RATED

ACCESS PNL

(COLOR- PT1)

WALL ACCESS PANEL

G5

1 1/2"=1'-0"

PLAN DET

G3

1 1/2"=1'-0"

ACCESS PANEL

G7

1 1/2"=1'-0"

SIZE

GWB J - BEAD

FLUSH ACCESS

PANEL

(PAINT-MATCH

ADJACENT FIN)

ANCHOR PER

MANUF

STANDARD

ANCHOR PER

MANUF

STANDARD

SIZE = SEE MECH DWGS FOR SIZE

AND LOCATION

3"

EQ.

3 5/8 "

EQ.

3 5/8 "

10'-2"

3"

(E) METAL

STUD

ACCESSORY

WALL MTD.

BLOCKING: 362

S125-43 MET

STUD FLUSH

WITH STUD

FACE

0 8"4"

GYP BD

FACE OF NEW

G9

CONCEALED BLOCKING

1 1/2"=1'-0"

P T

IO

N A

L V

A L

U E s b -1

A -5

.d

IS

C E

L L

A N

E O

U S D

E T

A

IL

S

A-504

BLDG 131

P

K A I

M

IF

G

S T

B

C H

U N

B

C H

U N

C D

V

IF1

O F F S

E T

1" VIF

LOBBY

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:50 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-505.dgn

J U

N E

RTA

1/4"Ø BOLT

@ 6" OC

2 EA-2"x2"

HINGE PER

GWB MFR;

WELD TO MET

FRAME

SEALANT

HEMMED

ANGLE

MOLDING C

L G H

T 7/8" MET FURG

@ 24" OC

1-1/2" MET

CHANNEL, 36"

LONG 2 EA AT

OPNG

DOOR CATCH

PER GYP BD

MFR

5/8" GYP BD

CEILING

MET TRIM ON

ALL EDGES OF

GYP BD OPNG

MAIN

RUNNER

HANGER

WIRE

FACE OF

WALL

WALL

TRIM

SPLICE

MAIN

RUNNER

SEISMIC

LOCKING PIN

CROSS TO MAIN RUNNER CONNECTION DETAIL

CROSS

RUNNER

EDGE BEAD

1/8" Ø MIN

VERT HANGER

WIRE @ 4'-0"

3 TURNS MIN

WITHIN 3" (TYP)

CROSS RUNNER

MAIN

RUNNER

CROSS

RUNNER

SPLAY

BRACE

WIRE

ISOMETRIC VIEW

DETAIL AT WALL

250S125-27

STUD @ 16" OC

A L

IG

N W

E X

S T C

M U

3" 3"

250S125-27

STUD @ 16" OC

A L

IG

N W

E X

S T C

M U

T Y

P

T Y P

2" M

AX.

M A X

2'-2 1/8 " VIF7 5/8 "2'-7 1/8 " VIF

A1A

SOFFIT

A1B

SOFFIT

A1C

SOFFIT

A1D

SOFFIT

A1E

SOFFIT

SOFFIT:

7'-0" AT LIVING

7'-2" AT KITCHEN

1'-5"

ALIGN WITH

PLAN WALL

ALIGN WITH

PLAN WALL

250S125-27

STUD @ 16" OC

RUNNER

MAIN

RUNNER

CROSS

CEILING TILE

ACOUSTIC

8" MAX.

FACE OF WALL

FACE OF WALL

FLEXIBLE

SEALANT

C L

G H

T

8" MAX.

12 GA WIRE

HANGER @

4'-0" OC

ANCHORED

TO PURLINS,

WIRE MUST

NOT EXCEED

1:6 SLOPE

WIRE TIE @

3'-0" OC

ANCHORED

TO PURLINS

24"x24" OPENING

4"

MET FRAMES

1 1/2" CHANNEL

AT 24" OC

NOTES:

1.SPLICES & INTERSECTIONS OF RUNNERS SHALL BE ATTACHED W/ MECH.

INTERLOCKING CONNECTORS SUCH AS POP RIVETS, SCREWS, PINS,

PLATES WITH BENT TABS, OR OTHER APPROVED CONNECTORS. DESIGN

CONNECTORS FOR 2X DESIGN LOAD OR ULTIMATE AXIAL TENSION OR

COMPRESSION (MIN. 120#)

2.APPLICABLE FOR SUSPENDED ACOUSTIC CEILING TILE IN AREAS LARGER

THAN 144 SF SURROUNDED BY WALLS THAT CONNECT DIRECTLY TO THE

STRUCTURE ABOVE PER ASTM E580.

45° SPLAY

WIRE (1/8" Ø

MIN.) BRACING

IN VERTICAL

PLANES

THROUGH

MAIN AND

CROSS

BRACING.

SPLAY WIRE

BRACING @

12'-0" OC IN

BOTH

DIRECTIONS

ALL WIRES

ATTACHED TO

MAIN RUNNER

- 4 WIRES.

CONT HORIZ

STRUT TO

PREVENT

SPREADING

OF RUNNERS

ACOUSTIC

CLG TILE

NOT TO EXCEED 4'-0"

6" MAX.

M A X

7'-0" SOFFIT

7'-0" SOFFIT

8'-0" CEILING

0 8"4"

0 8"4" 0 8"4" 0 8"4" F5

CEILING ACCESS PANEL

VARIES

SUSP ACT

5/8" GYP BD

BEAD

CORNER

SCREEN CASE

PROJECTION

BRACKET

HANGER

SCREEN

PROJECTION

AS SCHED

MET STUD

ROD (CFCI)

THREADED

3/8" Ø

16" OC

MET STUDS @

362S125-27

FLANGE

TRIM

ADJUSTABLE

PROJECTOR

MOUNT, SEE

SPEC

CROSS TEE

MAIN BEAM

@ 4'-0" OC

PROJECTOR

MOUNT

SUPPORT

POST AND

MOUNTING

PLATE

SCREEN WITH MANUFACTURER

VRFY PROJECTOR DISTANCE TO

0 8"4"

C L

G H

T A

S S

C H

E D

C L

G H

T A

S S

C H

E D

BD

5/8" GYP

SCREEN WITH MANUFACTURER

VRFY PROJECTOR DISTANCE TO

3"

UNISTRUT

ELECTRICAL

CONDUITS

2'-1" AT U108 LAV

7'-0" SOFFIT

ANCHOR

STUD TO

STRUCT AT

TOP &

MID-POINT

SEE DET A1B

FOR NOTES

8'-0" CEILING (VIF)

8'-0" CEILING (VIF)

SPRINKLER,

SEE FX DWGS

THREADED

ROD (TYP)

SPRINKLER

PARTITION

AS SCHED

NEW CONC BEAM,

SEE STRUCT

DWGS

NEW CONC

INFILL, SEE

STRUCT

EXST

MASONRY

EXST

MASONRY

2'-0"

8 1/8 "8 1/8 "

VIF VIF

ANCHOR TO

UNDERSIDE OF

STRUCT PER

MANUF

RECOMMEN-

DATIONS

SUSP ACT

THREADED

ROD

1 1/2"=1'-0"

E9

PROJECTOR MOUNT DET

PROJECTION SCREEN/

1 1/2"=1'-0"

A9

SUSP CLG SEISMIC DETAIL

NTS

A1

SOFFIT DETAIL

1 1/2"=1'-0"

F1

ACOUSTIC CLG TILE DET

1 1/2"=1'-0"

F3

GYPSUM BD CEILING DET

1 1/2"=1'-0"

SEE A1C/—

FOR NOTES

5/8" TYPE 'X'

GYP BD

5/8" TYPE 'X'

GYP BD

5/8" TPYE 'X'

GWB CLG

ACCESS PANEL

5/8" TYPE 'X'

GYP BD

GYP BD

5/8" TYPE 'X'

250S125-33

MET STUD

@ 24" OC

TRACK SHALL

MATCH SIZE AND

GAUGE OF STUD

1-1/2" METAL

CHANNEL @

48" OC

3'-3" UON7 5/8 "3'-3" UON

DRILL THRU

TRACK TO

SET ROD

20 GAGE

STEEL

COVER

PLATE 4"

LARGER

THAN OD OF

PIPE

1/8" Ø TOGGLE

BOLTS @ 6" OC

W/ 3/16"x1 1/4"

FENDER

WASHERS

SEALANT

FORM

ANNULAR

SPACE FROM

MTL STUD

TRACK

1/8" Ø TOGGLE

BOLTS @ 6" OC

W/ 3/16"x1 1/4"

FENDER

WASHERS

20 GAGE

STEEL COVER

PLATE 4"

LARGER THAN

OD OF PIPE

SECTION

MET STUD

PARTITION

MINERAL WOOL

IN ANNULAR

SPACE

A7B

THRU CMU OR CONC (FLOOR SLAB SIM)

ELEVATION

NON-HARDENING

ACOUSTICAL

SEALANT

OPENING 1"

TO 1 3/8"

LARGER THAN

OD OF PIPE

OR CONDUIT

A7A

THRU MET STUD PARTITION

CMU OR

CONC WALL

NON-HARDENING

ACOUSTICAL

SEALANT

PIPE OR

CONDUIT

HANGER OR

MOUNT PER

MECHANICAL

DRAWINGS

MINERAL

WOOL IN

ANNULAR

SPACE

OPENING 1"

TO 1 3/8"

LARGER THAN

OD OF PIPE

OR CONDUIT

SECTION

NOTE:

SEE PLUMBING, MECHANICAL, ELECTRICAL, AND

TELECOMMUNICATIONS DRAWINGS FOR ADDITIONAL

PENETRATION INFORMATION AND DETAILS.

ELEVATION

MET STUD

SLEEVE

AROUND

OPENING

"L" TRIM ON

ALL SIDES

DUCT, SEE

MECH DWGS

MET STUD

PARTITION

NON-HARDENING

ACOUSTICAL

SEALANT

STRAP OR

ISOLATION

HANGER PER

MECHANICAL

DRAWINGS

MINERAL WOOL

IN ANNULAR

SPACE

SHT MET SLEEVE

AROUND OPNG

CMU/CONC

WALL

OPNG 1/2" - 3/4"

LARGER THAN

DUCT SIZE ON

ALL SIDES

NOTE:

1.SEE MECHANICAL DRAWINGS FOR ADDITIONAL PENETRATION INFORMATION

AND DETAILS.

A7 at SMOKE PARTITION

PIPE PENETRATION

NTS

D5 at SMOKE PARTITION

DUCT PENETRATION

NTS

P T

IO

N A

L V

A L

U E s b -1

A -5

.d

A-505

IS

C E

L L

A N

E O

U S D

E T

A

IL

S

B131 / CUP

P

K A I

B

C H

U N

B

C H

U N

M

IF

GRID

GRID

GRID

C4

C3

C7

G5D7 G7G7D7

D3 D1D5D3D5 D1 B7B1 B3 B5

C1 BASE CABINET

C2 WALL CABINET

C3 SCRIBE - FINISH SHALL MATCH CAB DOOR/DRAWER FRONT

A1 REFRIGERATOR (GFGI)

A2 RANGE (GFGI) - 30 INCH CLEAR SPACE

A3 RANGE HOOD (CFCI)

A4 MICROWAVE (GFGI)

P1 SINK AND FIXTURE, SEE PLUMBING SPEC 22 00 00

P2 LAVATORY AND FIXTURE, SEE PLUMBING SPEC 22 00 00

W1 COUNTER & RANGE BACKSPLASH: CERAMIC TILE BETWEEN

TOP OF COUNTER AND UNDERSIDE OF WALL CABINET.

PROVIDE MET EDGE DET D9/A-507

PD POWER AND/OR DATA OUTLET, SEE ELEC/COMM DRAWINGS

U1 MEDICINE CABINET 16" x 30" (QTY 2)

U2 TOWEL RING (TR) (QTY 2)

U3 TOOTHBRUSH/TUMBLER HOLDER (TTH) (QTY 2)

U4 SOAP DISH (SD) (QTY 2)

C1 C1

C1 C1 C1

C2 C2 C2

C2

C2 C2

C2

C1

C1

C5

C5

C5 C5

C5

C7

C7

M1

M1

M1

M1

M1 M1

M1

M1

M1

M1

M1

M1

M1

C9

H2

M4

M3

W2

H2

W2

W2W2 W2

W2 W2

W2

M3 M3

M3

M3 M3 M3

M3

M4

M4

M4

M4 M4 M4

M4

M2M2

M2 M2 M2 M3

M7

C8

C6 C6

C6 C8

M6M6

M6 M6 M6

M8

C4

C3

C3

H1

H1

C4

S1S1 S1

S1 S1 S1

S1

C1

C5

W2

M1

W1

C2

M3

M7

C1

M1

M4

M7

M1

M3

W2

I1

I1

M1 M1

M1

C9

H2

M1

C9

M4

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:52 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-506.dgn

J U

N E

RTA

3/4 "

/8

/2

TAB FINGER

PULL (FLUSH

W/ RAIL TOP)

RABBET TOP

SURFACE OF

RAIL FOR FLUSH

TAB PULL

PLACEMENT

INSET PANEL:

HDWD VENEER

ON 1/4" MDF

CAB DET

G3

4"2"0

SCALE: 3" = 1'-0"

NOTE: HDWD= WD1

/8

TOP RAIL: NET

3/4" x 2" HDWD

STILE: NET

3/4" x 2" HDWD

BOTTOM RAIL: NET

3/4" x 3.5" HDWD

RABBET

STILE AND

RAIL (TYP)

MAX MARGIN

FOR ALL

DWR/DOOR

FRONTS

CASEWORK ELEV

30"

BOX

8 FT

7 FT

CASEWORK ELEVCASEWORK ELEV

8 FT

A3 A5 A7 SCALE: 3/8" = 1'-0"SCALE: 3/8" = 1'-0"

24"

BOX

21"

BOX

RANGE

(GFGI)

30"

BOX

30"

BOX

27"

BOX

21"

BOX

SCALE: 3/8" = 1'-0"

ID #

30"

BOX

30"

BOX

21"

BOX

24"

BOX

30"

BOX

CASEWORK ELEV

SCALE: 3/8" = 1'-0"A1

0 32"12" 0 32"12" 0 32"12" 0 32"12"

A2

30"

A1

30"

30"

BOX

27"

BOX

30"

BOX

21"

BOX

15"

BOX

15"

BOX

A4

A4

A2

W1

TYP

A3

KNEE

SPACE

7'-2"

C2

C1

C3

P1

C2

C1

C3C3

PD

PD TYP

PD

TYP

SHT KEYNOTES - CASEWORK ELEV

18"H A3

A1

CQ 141 BREAK 136 TYP UNIT LAV TYP U107 KITCHEN

(U108 SIM)

AP

APAP

W1

W1

P1

W1

PT1

WR GWB

3/4"

SCRIBE

3/4"

SCRIBE

3/4"

SCRIBE

3/4"

SCRIBE

30"

BOX

6"6"

8 FT

7 FT

78"LIGHT

FIXT

U2

U3

TYP

U1

TYP

P2

48"

TYP

TYP

CENTER LAV

U4

6" 3/4 "

MIRROR

42"

6" 3/4 "

C8

C3

EQ SCRIBE

BOTH SIDES

3/4"

SCRIBE

3/4"

SCRIBE

PT1

WR GWB

PT1

WR GWB

SHT KEYNOTES-

CABINET DET: SHELF,

SIDE PANELS, AND

BOTTOM SHALL BE

SIM TO C8

OPEN CABINET DEPTH

SHALL BE 14 INCHES

(BOTH SIDES)

AXIS OF

SYMMETRY

TYP. BOX DEPTH

B O

X H

G T

D W

R F

R O

N T

T

Y P

ID #

R 1-1/16"

(TYP.)

B O

X H

G T

B O

X H

G T

B O

X H

G T

H G

T H

G T

D W

R F

R O

N T

T

Y P

TYP. BOX DEPTH

SCALE: 1 1/2" = 1'-0"

BASE CABINET DET

0 8"4"

B1

SCALE: 1 1/2" = 1'-0"

BASE CABINET DET

0 8"4"

B3

SCALE: 1 1/2" = 1'-0"

BASE CABINET DET

0 8"4"

B5

SCALE: 1 1/2" = 1'-0"

BASE CABINET DET

0 8"4"

B7

SCALE: 1 1/2" = 1'-0"

WALL CABINET DET

0 8"4"

D7

SCALE: 1 1/2" = 1'-0"

BASE CABINET DET

0 8"4"

D1

SCALE: 1 1/2" = 1'-0"

BASE CABINET DET

0 8"4"

D3

SCALE: 1 1/2" = 1'-0"

BASE CABINET DET

0 8"4"

D5

SCALE: 1 1/2" = 1'-0"

WALL CABINET DET

0 8"4"

G5

SCALE: 1 1/2" = 1'-0"

WALL CABINET DET

0 8"4"

G7

3"

R 1-1/16"

(TYP.)

CABINET

BEYOND

2"

2'-0"

/4

1'-9" 7

/4

/4

1'-10 1/2 "

3"

/4

2'-0"

1'-10 1/2 "

3"

1'-11 1/2 "

1'-10" 5

/4

/4

/4

R 1-1/16"

(TYP.)

2'-0"

R 1-1/16"

(TYP.)

2'-1"

R 1-1/16"

(TYP.)

/4

2'-1"

1'-11 1/2 "

H G

T

TYP. BOX DEPTH

3"

R 1-1/16"

(TYP.)

1'-10" 5

2'-1"

1'-11 1/2 "

1'-0"

1'-11 1/2 "

3"

SCALE: 1 1/2" = 1'-0"

CLOSET SHELF DET

0 8"4"

G1

1'-0"

A F F

PT1

PT1

3"

1'-11 1/2 "

/4

1'-0"

1'-0"

6"

MID-POINT END

2"

3/4" PLYWD W/

1/4" HDWD

EDGE, PAINT

SHELF / ROD

BRACKET

S2 2" H

W1 W1 W1

S2 2" H S2

S1

1'-0"

1 x 4

1 x 4 CLEAT AT

ENDS, PAINT

1 x 4 CONT

1 x 4 AT BRKT W2

HDWD (WD1)

EDGE BAND

1/8" THK(TYP)

2'-1" a t

U N

IT

K

IT

C H

E N a t

U N

IT

K

IT

C H

E N a t

U N

IT

K

IT

C H

E N

QTY- 3

a t

R A

N G

O D

SLOT

2"

R 1/2"

RANGE HOOD

OUTLET

/4 a t

U N

IT

K

IT

/4

16"D

SHT KEYNOTES - CABINET DET

CASEWORK SHEET NOTES

S2 4" H

SS SINK

SINK

VIT CHINA

RESIL

BASE AS

SCHED

1.25" DIA CHROME

PLATED STL ROD

& END SUPPORT

QTY- 2

/4

F

IX

E D F

R O

N T a t

B R

E A

K a t

B R

E A

K a t

B R

E A

K

W1

1. SEE SHEET A-001 FOR GENERAL NOTES AND ABBREVIATIONS.

2. SEE SHEET AF601 FOR INTERIOR FINISH LEGEND, CODE ID,

PRODUCT DESCRIPTION, AND INTERIOR INFORMATION.

3. CASEWORK FABRICATION SHALL CONFORM TO AWI

STANDARD (MINIMUM) AS REFERENCED IN PROJECT

SPECIFICATIONS.

S1 SOLID SURFACE (SS1) COUNTERTOP ON 3/4" PLYWOOD -

TERMITE TREATED

S2 SOLID SURFACE (SS1) BACKSPLASH AND ENDSPLASH

(TOPSET)

C1 BASE AND WALL CABINET FABRICATION SHALL BE

FRAMELESS CONSTRUCTION. TYP. CABINET BOX (TOP, SIDE

AND BOTTOM PANEL): 3/4 INCH PRE-FINISHED LAMINATE

PLYWOOD SHEET GOODS (COLOR-WHITE)

C2 TYP. CABINET BOX (REAR PANEL): MELAMINE ON 1/4 INCH

VENEER CORE PLYWOOD PANEL PRODUCT.

C3 TYP. DRAWER BOX (SIDE, FRONT, & REAR PANEL): 1/2 INCH

PRE-FINISHED LAMINATE PLYWOOD PANEL (COLOR-WHITE).

PROVIDE WHITE VINYL TAPE FOR ALL EDGES

C4 TYP. DRAWER BOX (BOTTOM PANEL): MELAMINE ON 1/4 INCH

VENEER CORE PLYWOOD PANEL PRODUCT. SET INTO DADO

JOINT AT SIDE AND FRONT DRAWER BOX PANELS

C5 HINGED DOOR FRONT: STILE AND RAIL W/ INSET PANEL; SEE

DET G3/A-506. HARDWOOD (WD1)

C6 TOP DRAWER BOX FRONT: HARDWOOD (WD1) VENEER ON

3/4" VENEER CORE PLYWOOD. PROVIDE 1/8" HARDWOOD

(WD1) EDGE BAND

C7 DRAWER BOX FRONT: STILE AND RAIL W/ INSET PANEL; SEE

DET G3/A-506. HARDWOOD (WD1)

C8 FIXED PANEL FRONT: HARDWOOD (WD1) VENEER ON 3/4"

VENEER CORE PLYWOOD. PROVIDE 1/8" THICK HARDWOOD

(WD1) EDGE BAND

C9 ADJUSTABLE SHELF: 3/4" PRE-FINISHED LAMINATE PLYWOOD

PANEL (COLOR-WHITE) W/ VINYL EDGE TAPE ALL SIDES

M1 1 x 4 BRACE

M2 CABINET BASE PLATFORM

M3 ANCHOR CABINET TO BLOCKING

M4 BLOCKING: 362S125-43 MET STUD, SEE DET G9/A-504

M6 TOE-KICK: BASE AS SCHEDULED, SEE SHEET AF601

M7 1 x 4 CLEAT

M8 1 x 4 GLUE TO PLYWOOD FOR STRENGTH

H1 SOFT CLOSE UNDERMOUNT DRAWER SLIDE. FULL-EXTENSION

H2 RECESSED ADJUSTABLE SHELF STANDARD W/ CLIPS (WHITE)

I1 ILLUMINATION, SEE ELECTRICAL DWGS

W1 CERAMIC TILE BACKSPLASH (CT4); 1/8" GROUT JOINTS

W2 WALL BOARD AS SCHEDULED

P T

IO

N A

L V

A L

U E s b -1

A -5

.d

A-506

B131 / CUP

P

K A I

M

IL

L W

O R

K D

E T

A

IL

S

P

K A I

B

C H

U N

B

C H

U

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:54 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-507.dgn

J U

N E

RTA

CERAMIC TILE

ALUM EDGE

TRIM ABOVE

90° ALUM EDGE

CORNER TRIM

ABOVE

CONT MET

STUD BLKG

CERAMIC TILE

MET STUD

V A

R

IE

S

MORTAR BED

WATERPROOF

MEMBRANE

REINFORCING

0 2"1"

0 2"1" 0 2"1"

GROUT

5/8" TYPE 'X'

GLASS MAT

WR GYP TILE

BACKING BD

WP MEMBRANE

WP MEMBRANE

ALUM OUTSIDE

CORNER TRIM

BASE

A7

6"=1'-0"

TILE WAINSCOT CAP

B7

6"=1'-0"

TILE CORNER

B9

6"=1'-0"

5/8" TYPE 'X'

GLASS MAT

WR GYP TILE

BACKING BD

SEALANT

MET STUD

5/8" TYPE 'X'

GLASS MAT

WR GYP TILE

BACKING BD

MET STUD

FLOOR TILE

WP MEMBRANE

WALL TILE

TCNA W245

0 2"1" 0 2"1"

TILE TUB JOINT

D7

6"=1'-0"

1/2" GLASS

MAT WR GYP

TILE BACKING

BOARD

CERAMIC

FIELD TILE

/8 J

T

FACE OF EXST

MASONRY

1/2" GLASS

MAT WR GYP

TILE BACKING

BOARD 1/2 "

1/2" WR GYP BD

CERAMIC

FIELD TILE

TUB

CT-1

CT-1

FACE OF EXST

MASONRY

TILE WALL FIN EDGE

D9

6"=1'-0"

CLEAR

SILICONE

SEALANT (TYP)

ALUM EDGE

TRIM SATIN FIN

ALUM EDGE

TRIM SATIN FIN

1/8 "

5/8" TYPE 'X'

WR GYP BD

WP MEMBRANE

MORTAR BED

REINF

CONC

FLOOR TILE

GRATE

LC DRAIN

0 2"1"

GROUT

FLOOR DRAIN DETAIL

A9

6"=1'-0"

DRAIN BODY

WALL TILE

TCNA W245

WP MEMBRANE

TRENCH DRAIN

FLOOR TILE

MORTAR BED

REINF

MEMBRANE

GMGS

CONC

0 2"1"

GROUT

SEALANT

TRENCH DRAIN DETAIL

F7

6"=1'-0"

FLOOR TILE

BEYOND

WALL

ALIGN WITH

1"

/4

VINYL STRIP

FLEXIBLE

BASE

RETAINER

3/4" ALUM

SHOWER

F9

FLEXIBLE SHOWER THRES

FULL SIZE WOMEN SHOWER 113 & 156 ONLY 0 1"1/2"

0 2" 4"

4"

CERAMIC TILE

CERAMIC TILE

1/8" GROUT JT

(ALL SIDES)

ELEVATION

PLAN

SHOWER NICHE

A5

3"=1'-0"

SOLID SURFACE

(SS1)

SOLID SURFACE

BOX (SS1)

/2

/2

DADO JOINT

(TYP)

/2

TILE GROUT JT

PARTITION AS

SCHED

SEE INT ELEV FOR EXACT PLACEMENT

5/8" TYPE 'X'

GLASS MAT

WR GYPSUM

TILE BACKING

BOARD

5/8" TYPE 'X'

GLASS MAT

WR GYPSUM

TILE BACKING

BOARD

P T

IO

N A

L V

A L

U E s b -1

A -5

.d

IS

C E

L L

A N

E O

U S D

E T

A

IL

S

A-507

BLDG 131

P

K A I

B

C H

U N

B

C H

U N

M

IF

P

K

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

12:30:56 PM7/16/2019

c:\pw-work\poh-1\j3ec9pmk\d0244227\18sb04-131_A-601.dgn

J U

N E

RTA

GENERAL SHEET NOTES

DOOR SCHEDULE REMARKS

DOOR

SIZE

H TWNO. TYPE MATL

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

6'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

6'-0"

3'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

D3

D1

D1

D1

D1

D5

D1

D1

D3

D1

D1

D1

D1

D5

D1

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

TYPE MATL

DOOR DETAILS

HEAD JAMB THRES

F1

F1

F1

F1

F1

F3

F1

F1

F1

F1

F1

F1

F1

F3

F1

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

FIRE

RATING

HDWR

SET REMARKSSTC

MISCELLANEOUS

DOOR FRAME TYPES

DOOR TYPES

3'-0" 7'-0" 1 3/4" D1 HM F1 HM309

DOOR

SIZE

H TWNO. TYPE MATL

5'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

4'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

6'-0"

3'-0"

6'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

7'-8"

3'-0"

3'-0"

3'-6"

6'-0"

3'-0"

3'-0"

6'-0"

3'-0"

5'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

7'-10"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

6'-10"

7'-10"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-10

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-10"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-10"

7'-0"

7'-10"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-10"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

D4

D1

D1

D1

D1

D1

D2

D1

D1

D1

D3

D3

D1

D1

D1

D1

D6

D2

D1

D1

D1

D1

D1

D1

D3

S1

D2

D5

D1

D1

D2

D1

D1

D5

D2

D2

D3

D5

D2

D1

S1

D3

D4

D1

D1

D1

D1

D1

D2

D1

D1

D1

D1

D3

D3

D1

D1

D1

D2

D1

D1

D1

D1

D1

D1

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

TYPE MATL

DOOR DETAILS

HEAD JAMB THRES

F2

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

D6

F1

F1

F1

F1

F1

F1

F1

F1

S1

F1

F3

F1

F1

F1

F1

F1

F3

F1

F1

F1

F3

F1

F1

S1

F1

F2

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

F1

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

HM

FIRE

RATING

HDWR

SET

DOOR SCHEDULE

REMARKSSTC

MISCELLANEOUS

SEE DOOR DETAIL SHT A-603

9" STL STL

4'-0" 6'-10" 9" D6 STL D6 STL

5'-0" 7'-10" 1 3/4" D4 HM F2 HM

118A

118B

ALUM ALUM

ALUM ALUM

HM

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

5'-0" 7'-10" 1 3/4" D4 HM F2 HM

161A

161B

SCWD

SCWD

SCWD

SCWD

SCWD

FIRST FLOOR

SECOND FLOOR

THIRD FLOOR

20 MIN

20 MIN

20 MIN

45 MIN

20 MIN

20 MIN

20 MIN

20 MIN

20 MIN

20 MIN

45 MIN

20 MIN

20 MIN

20 MIN

45 MIN

20 MIN

45 MIN

20 MIN

20 MIN

20 MIN

20 MIN

20 MIN

20 MIN

20 MIN

20 MIN

3'-0"

3'-0"

10'-0"

3'-0"

7'-0"

7'-0"

8'-0"

7'-0"

1 3/4"

1 3/4"

1 3/4"

D1

D1

D7

D1

HM

HM

HM

F1

F1

D7

F1

HM

HM

HM

CP1A

CP1B

CP1C

CP2

CENTRAL UTILITY PLANT

2" STL STL

FRAMEFRAME

STOREFRONT TYPES

1 3/4"7'-0"3'-0" D1

2'-6"

3'-0"

7'-0"

7'-0"

7'-0"

7'-0"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

D1

D1

D1

D2 HM

3'-0" 7'-0" 1 3/4" D2 HM

F1 HM

F1

F1

F1

F1

F1

HM

HM

HM

HM

HM

U1

U2

U3

U4

S04A

S04

2'-6"

2'-6"

SCWD

SCWD

SCWD

SCWD

25 20 MIN

UNIT

STAIR

60 MIN

60 MIN

3'-0" 7'-0" 1 3/4" D2 HM F1 HMS05A

3'-0" 7'-0" 1 3/4" D2 HM F1 HMS05

60 MIN

60 MIN

SEE DOOR DETAIL SHT A-603

20 MIN

20 MIN

20 MIN

20 MIN

F9/A-603 D9/A-603 F9/A-603 D9/A-603

F7/A-603

F7/A-603

F7/A-603

F9/A-603

D7/A-603

D7/A-603

D7/A-603

D9/A-603

09A

09A

A1B/A-603

A1B/A-603

A1D/A-603

F9/A-603

F9/A-603

F9/A-603

D9/A-603

D9/A-603

D9/A-603

F9/A-603 D9/A-603

F9/A-603

F9/A-603

F7/A-603

D9/A-603

D9/A-603

D7/A-603

F7/A-603

F9/A-603

F9/A-603

D7/A-603

D9/A-603

D9/A-603

F9/A-603 D9/A-603

A1A/A-603

A1A/A-603

A1A/A-603

A1A/A-603

A1A/A-603

A1A/A-603

A1A/A-603

F9/A-603 D9/A-603

F9/A-603

F9/A-603

F7/A-603

D9/A-603

D9/A-603

D7/A-603

F7/A-603

F9/A-603

F9/A-603

D7/A-603

D9/A-603

D9/A-603

F9/A-603 D9/A-603

A1A/A-603

A1A/A-603

A1A/A-603

A1A/A-603

A1A/A-603

A1A/A-603

A1A/A-603

F9/A-603

F9/A-603

F3/A-603

F9/A-603

D9/A-603

D9/A-603

D3/A-603

D9/A-603

B3/A-603

A3/A-603

A3/A-603

A1B/A-603

F7/A-603

F9/A-603

F7/A-603

D7/A-603

D9/A-603

D7/A-603

A1C/A-603

F7/A-603

F7/A-603

F7/A-603

D7/A-603

D7/A-603

D7/A-603

F7/A-603

F7/A-603

F7/A-603

D7/A-603

D7/A-603

D7/A-603

A1C/A-603

A1C/A-603

F7/A-603

F7/A-603

F7/A-603

D7/A-603

D7/A-603

D7/A-603

F7/A-603

F7/A-603

F7/A-603

D7/A-603

D7/A-603

D7/A-603

F1/A-603

F7/A-603

F9/A-603

D1/A-603

D7/A-603

D9/A-603 A3/A-603

A1B/A-603

A1B/A-603

A1B/A-603

A1B/A-603

A1A/A-603

A1B/A-603

F7/A-603 D7/A-603

D7/A-603

B7/A-603

F7/A-603

F7/A-603

B7/A-603

A1B/A-603

A1B/A-603

A1B/A-603

A1B/A-603

B7/A-603

F7/A-603

F9/A-603

B7/A-603

B7 + D7

D9/A-603 A1A/A-603

F5 & B5

D9/A-603F9/A-603

A3/A-603F9/A-603

F7/A-603

F9/A-603

F9/A-603

D9/A-603

D7/A-603

D9/A-603

D9/A-603

F9/A-603

F9/A-603

F9/A-603

F9/A-603

D9/A-603

D9/A-603

D9/A-603

D9/A-603

A1B/A-603

F9/A-603

F9/A-603

F9/A-603

F9/A-603

F9/A-603

D9/A-603

D9/A-603

D9/A-603

D9/A-603

D9/A-603

A3/A-603

F5 & D5

D7 & D9

F5 & D5 F5 & B5 A1B/A-603

A1B/A-603

F9/A-603 D9/A-603 A1A/A-603

F9/A-603 D9/A-603 A1B/A-603

F7/A-603 D7/A-603

F9/A-603 D9/A-603 A1C/A-603

F7/A-603 D7/A-603 A1B/A-603

A1B/A-603

A1B/A-603

A1B/A-603

A1A/A-603

A1B/A-603D7/A-603

D7/A-603

D7/A-603

D7/A-603

D7/A-603F7/A-603

F7/A-603

F7/A-603

F7/A-603

F7/A-603

F7/A-603 D7/A-603

A1C/A-603

A1C/A-603

D7/A-603

D7/A-603

D7/A-603F7/A-603

F7/A-603

F7/A-603

F7/A-603 D7/A-603

F7/A-603 D7/A-603

D7/A-603

D1/A-603

D7/A-603F7/A-603

F1/A-603

F7/A-603

F9/A-603 D9/A-603 A3/A-603

F7/A-603 A1B/A-603

A1B/A-603

A1B/A-603

A1B/A-603

D7/A-603F7/A-603

F7/A-603

F7/A-603 D7 & D9

D7/A-603

A3/A-603

B7/A-603

B7/A-603 B7/A-603

B7/A-603

B7 + D7

1, 3

SEE STOREFRONT DETAIL SHT A-603

B1/A-603

A3/A-603

A3/A-603

B1/A-603

A3/A-603

A3/A-603

07A

07A

12A

12A

12A

3'-0" 7'-0" 1 3/4" D2 HM F1 HM 16F9/A-603 D9/A-603

2'-0" 3'-0" 1 3/4" D1 HM F1 HM 26F7/A-603 D7/A-603

129A

129B

129C

E9/A-504

SEE SHEET A-603, DOOR AND STOREFRONT DETAILS8.

INTERIOR HM DOOR FRAME SHALL BE PAINT COLOR PT37.

MET ANCHOR BOLTS AND PLASTIC SHIMS

HOLLOW METAL FRAMES SHALL BE INSTALLED UTLIZING 6.

FN-1 (SEE SHEET A-201 EXTERIOR COLOR LEGEND)

ALUMINUM STOREFRONT FRAME COLOR SHALL MATCH 5.

FRAME FINISH

SEE SHEET AF601, GENERAL NOTES FOR DOOR AND 4.

FIRE RATED GLAZING AT STAIR VISION PANELS.

1/4" LAMINATED SAFETY GLASS. PROVIDE 60 MIN G2

TRANSMITTANCE -MIN 66%

LAMINATED INNER PANE. VISIBLE LIGHT

1" INSULATED, LOW 'E' GLASS ASSEMBLY W/ G1

GLAZING:3.

INFORMATION

10. SEE STRUCTURAL DWGS…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.