W9128A-19-R-0014_Am-0001_Drawings_-_Package_2_(Part_2_of_2).pdf
PDF 8 MB Posted
- Attached to
- Quad A, Building 131 and Central Utility Plant (CUP), and Buildings 130 and 132, Schofield Barracks, Hawaii
- Solicitation number
- W9128A-19-R-0014
About this file
W9128A-19-R-0014 Am-0001 Drawings - Package 2 (Part 2 of 2)
View the file
Other files
Show 40 more
Latest 50 of 52 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E-101
A
A.5
BLDG 130
s b -1
E -1
.d g n
B D
E A
D M
IN
IS
T R
A T
IO
N W
IN
G
F
IR
S T F
L O
O R E
L E
C T
R
IC
A L P
L A
N
SCALE: 1/8" = 1'-0"
B1
FIRST FLOOR ELECTRICAL PLAN - BDE ADMINISTRATION WING
MATCHLINE, SEE THIS SHEET
B
C
D
E
2 3 5
1 4
MATCHLINE, SEE THIS SHEET
BOLD LINES DENOTE NEW WORK.1.
NOTES:
M A
T C
H L
IN
E S
E E S
H E
E T
E -1
1HP/460V/3PH
FCU 130-5
12A-28,30,32
223W/115V/1PH
FCU 130-6
40W/120V/1PH, TYP
VAV
12A-11,13,15
12A-12,14,16
CRAWL SPACE BELOW
TO PANEL "MDP2" THROUGH
SEE
FOR WORK IN THIS ROOM,
ROOM, SEE
FOR WORK IN THIS
VIDEO MONITOR
+60" AFF FOR
D1
E-402
D6
E-403
A1
12A-1,3,5
12A-2,4,6
12A-21,23
3/4"C, 3#10, #10 GND
12L-1,5,9
PANEL "12L"
PANEL MDP2
SPACE AND HOMERUN TO
, TRANSITION TO CRAWL
3 , TYPICAL
FOR WORK IN THIS ROOM, SEE
NEMA 14-30R, TYP
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
12A-3612A-37
12S-27,29,32
333W/115V/1PH
FCU 130-9
PROJECTOR SCREEN
COORDINATE LOCATION OF ROUGH IN WITH FURNITURE PLAN AND ORDER.
SEE STRUCTURAL DRAWINGS FOR FOOTING PENETRATION AND SLAB REPAIR DETAILS.
DISCIPLINES. SEE STRUCTURAL DRAWINGS FOR FLOOR REPAIR DETAILS.
SAWCUT/CHIP EXISTING CONCRETE FLOOR TO EMBED CONDUIT. COORDINATE SIZE OF TRENCH WITH OTHER
FOR PROJECTOR
MOUNT RECEPTACLE
FLUSH CEILING
A M
E N
D M
E N
T
1/4HP/115V/1PH
FCU 130-12 1
J
U L
Y
ELEC
LOBBY
STAIR
S01
MECH
VEND
SEC DOC
SERVER
NOC
CORR
WOMEN
MEN
EF
LAUNDRY
CONF
STOR
SHWR
MEN
SHWR
WOMEN
STAIR
S02
STAIR
S03
STAIR
S04
VT CONF
VEST
TR
SIGINT
S-3 STOR
S-2 STOR
AREA
SECURE
JAN
S-6 STOR
S-3 FILES
ACCESS
134C
MAILROOM
S-3 OFF
S-6 OFF
OFF
SURGEON
S-2 OFF
SGT OFF
S-3 OPS
WORKSTATIONS
S-2/S-3/S-6
CT
ROOM, SEE
FOR WORK IN THIS
FOR WORK IN THIS ROOM, SEE
D2
C2
E-405
V
F
F
F
F
F
F
89W/115V/1PH
EF 130-2
1.5HP/460V/3PH
FCU 130-4
29 29
12A-29
12S-5,7
12A-31
CT
CT33 35
CT
35 CT
12A-33,35
VIA EF 130-6
TO 12A-34
1 3
3 3
12S-1,3
V
12S-2412S-9,11
85W/115V/1PH
FCU 130-7
11 9
10 8
85W/115V/1PH, TYP
FCU 130-8
12A-22,24,26
VIDEO MONITOR
+60" AFF FOR
VIDEO MONITOR
+60" AFF FOR
2,4,6
12S-
12S-26,28,30
10,12
12S-8, MONITOR
FOR VIDEO
+60" AFF
14A-6
F
ID
ID
12L-10
12L-8
2,4,6
12L-
12S-29
C
C
C
C
C
C
13 17 C
C
C
12S-13,17
12S-16,20
12S-14,18
12S-22
12S-21
CT35
WP
12S-21,22,33
E
12S-37
M
C
M E
12A-38
FOR PROJECTOR
MOUNT RECEPTABLE
FLUSH CEILING
E
EWC RECEPATCLE
DISCONNECT
WITH INTEGRAL
3/4HP/208V/1PH
ERV 130-2 2
12DA-40
F
12S-23,25
V V
V V
J
J J
J
FC
FC
FC
12A-25,27 32
27 32 32
28 32
V V V
V V
V
J
FC
J
J
J
FC
FC
FC
FC
23 21 21
12A-7,9
12A-8,10
12A-17,19
12A-18,20
E
A
211661
A.5
F
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
U
O P
T
IO
N
S C
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
H O
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
0 8'4' 16'
SCALE: 1/8"=1'-0"
PLAN
NORTH
KEY PLAN
Paul Uyeda
E-102
BLDG 130
s b -1
E -1
.d g n
B D
E A
D M
IN
IS
T R
A T
IO
N W
IN
G
F
IR
S T F
L O
O R E
L E
C T
R
IC
A L P
L A
B6
E -1
B
C
D
E
BOLD LINES DENOTE NEW WORK.1.
NOTES:
BDE ADMINISTRATION WING
FIRST FLOOR ELECTRICAL PLAN -
F
A.5
16 17 18 19 20 21
M A
T C
H L
IN
E S
E E S
H E
E T
NEMA 14-50
CT
VIDEO MONITORS
+60" AFF FOR
1"C, 3#8, #10 GND
12D-7
DISPOSAL
GARBAGE
12D-6,8
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
+80 AFF
MICROWAVE
TYPICAL
GROUND ROD,
TYPICAL
#2/0 BC GND,
CONTINUATION
SEE FORES101
PROJECTOR SCREEN
RECEPTACLE FOR PROJECTOR
FLUSH CEILING MOUNT
FMCP, MTR, FTR, FEP, HOME RUN TO MINI POWER CENTER.
3 - 4"C FOR SERVICE, 1 - 2"C FOR GROUND
DRAWINGS.
COORDINATE LOCATION OF RECEPTACLE WITH ARCHITECTURAL
SLAB REPAIR DETAILS.
SEE STRUCTURAL DRAWINGS FOR FOOTING PENETRATION AND
SEE STRUCTURAL DRAWINGS FOR FLOOR REPAIR DETAILS.
COORDINATE SIZE OF TRENCH WITH OTHER DISCIPLINES.
SAWCUT/CHIP EXISTING CONCRETE FLOOR TO EMBED CONDUIT.
A M
E N
D M
E N
T
1 1
J
U L
Y
ELEC
LOBBY
S-4 FILES
CORR
S-1 FILES
S-4 OFF
S-1 OFF
CMD CONF
SGT OFF
SR HR
MEN
WOMEN
STOR
S-1/S-4
OFF
FRSA
OFF
REENLIST
CORR
STOR
CMD
MECH
TR
CHAPLAIN
ASST
CHAPLAIN
ELEC
BREAK
CQ
STAIR
S08
VEND
S-1/S-4 WS
S-1/S-4 WS
S-1/S-4 WS
CMD WS
CSM
CMD
DUTY
DEP CMD
TOILET
CMD
STAIR
S07
STAIR
S06
STAIR
S05
JAN
ROOM, SEE
FOR WORK IN THIS
ROOM, SEE
FOR WORK IN THIS
ROOM, SEE
A6
D5
C6
E-405
CT
V
V
40W/115V/1PH, TYP
VAV
V
F
V
V
V
V
V
V
V
V V
V
V
VV
V
V
V
80W/115V/1PH
EF 130-2
60W/115V/1PH
EF 130-1
85W/115V/1PH
FCU 130-11
THIS ROOM, SEE
FOR WORK IN
2 4 12B-2,4
12B-1,3,5
12B-7,9
12B-6,8
12B-11,13
12B-27
12B-10,12,14
12B-25
12B-26 18,20
12B-16, 20 16 18
20 20
12B-17,19
12D-3
12D-5
12D-4
F
F
VIA EF 130-7
12D-2
22,24
12B-
12B-15
130-6
VIA EF
12F-10
21,23
12B-
3 , TYPICAL
12D-20
C 2
G G
5' MIN
12F-3,5
12F-4,6
12F-7
E
12B-28
M
V
E
A
211661
A.5
F
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
0 8'4' 16'
SCALE: 1/8"=1'-0"
PLAN
NORTH
KEY PLAN
E-105 s b -1
E -1
.d g n
SCALE: 1/8" = 1'-0"
A4
BOLD LINES DENOTE NEW WORK.1.
NOTES:
B
C
D
E
THIRD FLOOR ELECTRICAL PLAN - UEPH
T H
IR
D F
L O
O R E
L E
C T
R
IC
A L P
L A
N U
E P
H
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
FLOOR. SEE STRUCTURAL DRAWINGS FOR SPACING REQUIREMENTS.
HOMERUN TO MINI POWER CENTER. XRAY AND TONE PRIOR TO CORE DRILLING 2
3.
UNLESS INDICATED ON THE STRUCTURAL DRAWINGS.
PRESTRESSED CONCRETE PLANKS (TYPICAL FLOOR CONSTRUCTION)
THERE SHALL BE NO PENETRATIONS MADE THROUGH THE EXISTING
A M
E N
D M
E N
T
J
U L
Y
MECH
STAIR
S04
STAIR
S05
JAN
ELEC
VEND
LAUNDRY
TR
UNIT
U302
UNIT
U304
UNIT
U306
CORR
UNIT
U308
MECH
STOR
UNIT
U310
UNIT
U303
UNIT
U305
UNIT
U307
UNIT
U309
STOR
UNIT
U301
5 6 7 8 9 10 11 12 13 14 15 16 17
E-401
TYPICAL FOR NORTH SIDE
AREAS, SEE ,
FOR WORK IN LIVING
TYPICAL FOR SOUTH SIDE
AREAS, SEE ,
FOR WORK IN LIVING
A5
E-401
F
3/4HP/115V/1PH
FCU 130-11
3PH
27A/460V/
DOAS 130-1
C6
E-407
C2
E-407
#10 GND
3/4"C, 4#10, 32A-3,5,7
32A-8
M
32A-6
33A-2,4
32A-9,11
FOR WORK IN THIS ROOM, SEE
FOR WORK IN THIS ROOM, SEE
32A-1
CT
3/4"C,3#10, #10 GND
32A - 9,13,17
10,12,14
32A-
NEMA 14-30R, TYP
E5 #10 GND
2#10, 3/4"C, 32A-7 PANEL
DDC
F #10 GND
1"C, 3#10, MDP-8
2HP/115V/1PH
EF 130-7
12F-12
E
A
211661
A.5
F
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
0 8'4' 16'
SCALE: 1/8"=1'-0"
PLAN
NORTH
s b -1
E -4
.d g n
BOLD LINES DENOTE NEW WORK.1.
SCALE: 1/2" = 1'-0"
A1
SCALE: 1/2" = 1'-0"
D5
SCALE: 1/2" = 1'-0"
D1
NOTES APPLICABLE FOR THIS SHEET:
B
C
E
EF 130-5
480/277V, 3PH, 4W
PANEL "14A"
208/120V, 3PH, 4W
PANEL "12B"
XFMR
480-208Y/120V
75 KVA,
480/277V, 3PH, 4W
PANEL "14B"
0 1' 2' 3' 4'
SCALE: 1/2"=1'-0"
E L E
C T
R
IC
A L P
L A
N S
F
IR
S T F
L O
O R E
L E
C R
O O
M E
N L
A R
G E
135W/115V/1PH
EF 130-6
PANEL "12D"
480Y/277V, 3PH, 4W
PANEL "MDP"
FOR FIRE ALARM
MINI POWER CENTER
PENETRATION AND SLAB REPAIR.
SEE STRUCTURAL DRAWINGS FOR BUILDING
SEE STRUCTURAL DRAWINGS FOR SLAB REPAIR.
CUT EXISTING CONCRETE SLAB FOR NEW WORK.
208/120V, 3PH, 4W
PANEL "12DA"
208/120V, 3PH, 4W
PANEL "12S"
XFMR
480-208Y/120V
75 KVA,
208/120V, 3PH, 4W
PANEL "12DB"
208/120V, 3PH, 4W
PANEL "12A"
CT CABINET
GROUND BUS
METER AND
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
GB1
208Y/120V,3PH, 4W
PANEL "MDP2"
12F-1
PANEL "12F"
ELECTRICAL PLAN - ELEC ROOM 130
FIRST FLOOR ENLARGED
ELECTRICAL PLAN - ELEC ROOM 144
FIRST FLOOR ENLARGED
ELECTRICAL PLAN - ELEC ROOM 149
FIRST FLOOR ENLARGED
GB2
480-208Y/120V, XFMR
225 KVA,
4"C TO PANEL "UEPH-2"
A M
E N
D M
E N
T
J
U L
Y
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
ELEC
ELEC
ELEC
12A-36
12S-31
F
1A
XFMR
12D-2
12D-1
1B
XFMR
F
F
135W/115V/1PH
EF 130-4
12F-2
2A
XFMR
E-701 s b -1
E -7
.d g n
P A
N E
L S
C H
E D
U L E
S
BLDG 130
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
A M
E N
D M
E N
T
J
U L
Y
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
E-703 s b -1
E -7
.d g n
P A
N E
L S
C H
E D
U L E
S
BLDG 130
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
A M
E N
D M
E N
T
J
U L
Y
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
E-704 s b -1
E -7
.d g n
P A
N E
L S
C H
E D
U L E
S
BLDG 130
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
A M
E N
D M
E N
T
J
U L
Y
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
E-153
NOTES:
B4
THIRD FLOOR ELECTRICAL PLAN
T H
IR
D F
L O
O R E
L E
C T
R
IC
A L P
L A
N
BLDG 132
s b -1
E -1
.d g n
BOLD LINES DENOTE NEW WORK.1.
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
INDICATED ON THE STRUCTURAL DRAWINGS.
PRESTRESSED CONCRETE PLANKS (TYPICAL FLOOR CONSTRUCTION) UNLESS
THERE SHALL BE NO PENETRATIONS MADE THROUGH THE EXISTING
HOMERUN TO PANEL "B" VIA PIPE CHASES AND CRAWL SPACE BELOW.
3.
A M
E N
D M
E N
T
J
U L
Y
STORAGE
ELEC
UNIT
U302
UNIT
U301
STAIR
S02
UNIT
U304
CORR
UNIT
U303
LAUNDRY
306 STOR
VEND
TR
UNIT
U306
STAIR
S04
JAN
MECH
D
C
B
A
2 3 4 5 6 7
ROOMS, SEE
FOR WORK IN THESE
TYPICAL FOR NORTH SIDE
AREAS, SEE ,
FOR WORK IN LIVING
TYPICAL FOR SOUTH SIDE
E-451
A6
E-453
E-451
J
NEMA 14-30R
CT
17 17
B-18,20
3/4"C, 3#10, #10 GND
B-22,26
B-11
34 15
B-15,17,34
F
B-9
3/4HP/115V/1PH
EF 132-3
A
D
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
SCALE: 1/8"=1'-0"
PLAN
NORTH
KEY PLAN
0 8'4'
E-452
BLDG 132
s b -1
E -4
.d g n
F
IR
S T F
L O
O R E
N L
A R
G E
D E
L E
C T
R
IC
A L P
L A
N S
SCALE: 1/2" = 1'-0"
A7
1.
NOTES APPLICABLE FOR THIS SHEET:
SCALE: 1/2" = 1'-0"
C1
SCALE: 1/2" = 1'-0"
A4
C
C
D
2 3
0 1' 2' 3' 4'
SCALE: 1/2"=1'-0"
B
208Y/120V, 3PH, 4W
PANEL "UEPH"
208Y/120V, 3PH, 4W
PANEL "MDP"
208Y/120V, 3PH, 4W
PANEL "A"
BOLD LINES DENOTE NEW WORK.
LIGHT LINES DENOTE EXISTING CONDITION.
A-22
A
208Y/120V, 3PH, 4W
PANEL "B"
PANEL "FA"
PANEL "EF"
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
ELECTRICAL PLAN - ELEC ROOM 106
FIRST FLOOR ENLARGED
ELECTRICAL PLAN - MECH ROOM 107
FIRST FLOOR ENLARGED
ELECTRICAL PLAN - ER 112/MECH ROOM 111
FIRST FLOOR ENLARGED
FOR CONTINUATION
SEE ET151
53W/115V/1PH
FCU-132-8
5.
UNIT RISERS
2 - 1-1/2"C FOR
STRUCTURAL DRAWINGS.
FLOOR CONSTRUCTION) UNLESS INDICATED ON THE
EXISTING PRESTRESSED CONCRETE PLANKS (TYPICAL
THERE SHALL BE NO PENETRATIONS MADE THROUGH THE
WORKING CLEARANCE FOR ALL STARTERS AND SWITCHES.
COORDINAT WITH MECHANICAL AND PROVIDE NEC
OVERHEAD CONDUIT FOR TELECOM OUTLETS.
MOUNT OUTLETS TO TELECOM RACK.
FMCP, MTR, FTP, FEP HOMERUN TO PANEL "FA".
6.
A M
E N
D M
E N
T
J
U L
Y
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
F
E
1/2HP/208V/3PH
EXISTING AHU-1
A-24
EF-2,4
EF-6
EF-7
L6-20R
J
4EF-1,3,5
E
A-23
120V DDC PANEL
E
J
DETECTOR
AND DUCT SMOKE
115V UV LIGHTS
E
DETECTOR
DUCT SMOKE
TMGB
333W/115V/1PH
FCU 132-5
F
A-30
0.17HP/115V/1PH
EF 132-1
A-21
A-19
E
A-25
GWH
M
E M
E M
J
J
FOR UNIT FEEDERS
2 - 36" x 36" x 12" JB
F
MECH
EF
ELEC
MECH
E-453
BLDG 132
s b -1
E -4
.d g n
1.
NOTES APPLICABLE FOR THIS SHEET:
SCALE: 1/2" = 1'-0"
A1
6 7
A
B
E L E
C T
R
IC
A L P
L A
N S
S E
C O
N D A
N D T
H
IR
D F
L O
O R E
N L
A R
G
0 1' 2' 3' 4'
SCALE: 1/2"=1'-0"
6 7
A
B
SCALE: 1/2" = 1'-0"
A6
BOLD LINES DENOTE NEW WORK.
LIGHT LINES DENOTE EXISTING CONDITION.
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
ELECTRICAL PLAN - MECH 207/TR ROOMS 208
SECOND FLOOR ENLARGED
ELECTRICAL PLAN - MECH 307/TR ROOMS 308
THIRD FLOOR ENLARGED
3.
THE STRUCTURAL DRAWINGS.
(TYPICAL FLOOR CONSTRUCTION) UNLESS INDICATED ON
THE EXISTING PRESTRESSED CONCRETE PLANKS
THERE SHALL BE NO PENETRATIONS MADE THROUGH
SWITCHES.
WORKING CLEARANCE FOR ALL STARTERS AND
COORDINAT WITH MECHANICAL AND PROVIDE NEC
FOR SPACING REQUIREMENTS.
CORE DRILLING FLOOR. SEE STRUCTURAL DRAWINGS
HOMERUN TO PANEL "FA". XRAY AND TONE PRIOR TO
4.
A M
E N
D M
E N
T
J
U L
Y
E
1/2HP/208V/3PH
EXISTING AHU-2
82W/115V/1PH
FCU 132-7
TR308-6
F
E
B-27
TR308-1,3,5
L6-20R
TR308-4
B-16
208Y/120V, 3PH, 4W
PANEL "TR308"
TR308-2
TR308-7
DETECTOR
AND DUCT SMOKE
115V UV LIGHTS
E
B-30
DDC PANEL
TGB-2
E
E
J
DETECTOR
DUCT S,OKE
1"C, 3#10, #10 GND
B-33
28A/208V/3PH
DOAS 132-1
MECH
TR
MECH
TR
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
F 82W/115V/1PH
FCU 132-6
1/2HP/208V/3PH
EXISTING AHU-1
E
TR208-6
208Y/120V, 3PH, 4W
PANEL "TR208"
L6-20R
TR208-1,3,5
B-21
TR208-4
B-2
TR208-2
TR208-7
E
J
DETECTOR
AND DUCT SMOKE
115V UV LIGHTS
E
B-19
DDC PANEL
E
DETECTOR
DUCT SMOKE
TGB-1
E-751 s b -1
E -7
.d g n
P A
N E
L S
C H
E D
U L E
S
BLDG 132
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
A M
E N
D M
E N
T
J
U L
Y
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
T-103 s b -1
T -1
.d g n
SCALE: 1/8" = 1'-0"
B6
T -1
1.
NOTES:
16 17 18 19 20 21
M A
T C
H L
IN
E S
E E S
H E
E T
BDE ADMINISTRATION WING
FIRST FLOOR TELECOMMUNICATIONS PLAN -
B D
E A
D M
IN
IS
T R
A T
IO
N W
IN
G
F
IR
S T F
L O
O R T
E L E
C O
M M
U N
IC
A T
IO
N S P
L A
BOLD LINES DENOTE NEW WORK.
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
A M
E N
D M
E N
T
J
U L
Y
STUB UP WITHIN FURRED WALL AND EXTEND CONDUIT TO CABLE TRAY.
COIL 20 FEET OF SLACK IN CABLE TRAY IN EF 135.
AMI METER 1"C, 1-2/C AND 1-4/C RS-485 CABLE TO EF 135 VIA CRAWL SPACE.
DETAILS.
SEE STRUCTURAL DRAWINGS FOR FOOTING PENETRATION AND FLOOR REPAIR
STRUCTURAL DRAWINGS FOR FLOOR REPAIR DETAILS.
SAWCUT/CHIP EXISTING CONCRETE FLOOR TO EMBED CONDUIT. SEE
B
C
D
E
F
A.5
ELEC
LOBBY
S-4 FILES
CORR
S-1 FILES
S-4 OFF
S-1 OFF
CMD CONF
SGT OFF
SR HR
MEN
WOMEN
STOR
S-1/S-4
OFF
FRSA
OFF
REENLIST
CORR
STOR
CMD
MECH
TR
CHAPLAIN
ASST
CHAPLAIN
ELEC
BREAK
CQ
STAIR
S08
VEND
S-1/S-4 WS
S-1/S-4 WS
S-1/S-4 WS
CMD WS
CSM
CMD
DUTY
DEP CMD
TOILET
CMD
STAIR
S07
STAIR
S06
STAIR
S05
JAN
BATH
ROOM, SEE
T-402
C
C
C
C
C
C
C
C
C
C
C
C
C
CC
C
C C
C
C
C
C
C
C
C
C
C
C
C C
C
C
C D
D CT (18")
C T
C
C C
C CC
C C
C CC
C C
C
C
C
C
C
C C
J
J
C
C T
(1
T
E
DDC PANEL
1 RG-11
1 - 2"C
CATV
M
C
VIDEO MONITORS
+60" AFF FOR
M
1 - 1/2"C FOR GROUND
BACKBONE CABLING
2 - 4"C FOR
J 16" x 12" x 6" JB
2 T 4 D
4 - CAT 6
1"C, 2 x (1"C, 4 - CAT 6)
CABLE TRAY
STUB CONDUIT TO
1"C, 1 RG 6.
1"C, 2 - CAT 6
C
FOR PROJECTOR
FLUSH CEILING MOUNTED
E
A
211661
A.5
F
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
0 8'4' 16'
SCALE: 1/8"=1'-0"
PLAN
NORTH
T-402 s b -1
T -4
.d g n
BOLD LINES DENOTE NEW WORK.1.
NOTES APPLICABLE FOR THIS SHEET:
SCALE: 1/4" = 1'-0"
E1
F
IR
S T F
L O
O R E
N L
A R
G E
D T
E L E
C O
M P
L A
N S
D
SCALE: 1/4" = 1'-0"
E5
0 1' 2' 3' 4'
SCALE: 1/2"=1'-0"
SCALE: 1/4" = 1'-0"
A1
SCALE: 1/4" = 1'-0"
A5
B
C
TO TELECOM ROOM 122
PANEL "EF"
PANEL "TR 156"
SEE STRUCTURAL DRAWINGS FOR SLAB REPAIR.
COORDINATE SIZE OF TRENCH WITH OTHER DICIPLINE.
CUT EXISTING CONCRETE SLAB FOR NEW WORK.
PENETRATION AND SLAB REPAIR.
SEE STRUCTURAL DRAWINGS FOR BUILDING
STUB CONDUIT AT PATHWAY.
PROVIDE FIRE RATED PATHWAY.
AND GROUND
BACKBONE CABLING
2 - 4"C, 1 - 1-1/2"C FOR
GROUND
CABLING AND
BACKBONE
2 - 1-1/2"C FOR
4 - 4"C, GROUND
CABLING AND
BACKBONE
1 - 1-1/2"C FOR
2 - 4"C, CONDUITS
SERVICE ENTRANCE
110 BLCOKS
110 BLCOKS
(BY OTHERS)
FUTURE CATV EQUIPMENT
(BY OTHERS)
FUTURE CATV EQUIPMENT
110 BLCOKS
24"W x 8'H
TRAY LADDER (TYP)
NEW VERTICAL CABLE
FROM EF 130 TO TR 206
RATED PATHWAYS
PROVIDE 4 - 4"SQ FIRE
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
TGB-1B
FIRST FLOOR ENLARGED TELECOM PLAN - EF ROOM 135 FIRST FLOOR ENLARGED TELECOM PLAN - TR ROOM 122
FIRST FLOOR ENLARGED TELECOM PLAN - TR ROOM 156 FIRST FLOOR ENLARGED TELECOM PLAN - SERVER ROOM 123
SERVER
REINSTALL ILON
A M
E N
D M
E N
T
J
U L
Y
F R
O N
T
TMGB
TERMINAL
ENTRANCE
PROTECTIVE
C
TYPICAL
BOTTOM (8'-0"),
+12" AFF TO
BACKBOARD
RATED
3/4" THICK FIRE
OTHERS)
EQUIPMENT (BY
FUTURE CATV
M
IN
M
IN
36" MIN 36" MIN
AND 135.02
RACK135.01
TELECOM
1-1/2"DEEP
TYPE
LADDER
TRAY,
18" CABLE
C
E
F R
O N
T
PANEL "TR 122"
TYPICAL
BACKBOARD,
RATED TELECOM
3/4" THICK FIRE
C T
C
M
IN
TELECOM RACK 122.01
M
IN
36" MIN36" MIN
TGB-1A
DEEP
LADDER TYPE 1-1/2"
18" CABLE TRAY,
EF
TR
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
C
C T
TYPICAL
BACKBOARD,
RATED TELECOM
3/4" THICK FIRE
F R
O N
T
M
IN
36" MIN
36" MIN
M
IN
156.01
TELECOM RACK 1-1/2" DEEP
LADDER TYPE
18" CABLE TRAY,
C C
C C C
TR
SERVER
Paul Uyeda
Paul Uyeda
T-151
NOTES:
B4
BLDG 132
s b -1
T -1
.d g n
BOLD LINES DENOTE NEW WORK.1.
FIRST FLOOR TELECOMMUNCIATIONS PLAN
F
IR
S T F
L O
O R T
E L E
C O
M M
U N
IC
A T
IO
N S P
L A
N
OR UNDER MY SUPERVISION.
THIS WORK WAS PREPARED BY ME
LICENSE EXPIRATION DATE: 4/30/20
MK ENGINEERS, LTD.
P
A
ED
A
Y
.A S
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A .
,II
A H
W U
U L
K.U
PROVIDE 2"C ONLY WITH PULLSTRING. CONTROL WIRING PROVIDED BY OTHERS.
CONDUITS SHOWN ARE SPECIFIC TO UNIT.
HIGH SOLID CABLE TRAY MOUNTED +7'-4" AFF TO BOTTOM OF TRAY. SECTION
CABLE TRAY INTO 2 - 6" SECTIONS.
A M
E N
D M
E N
T
J
U L
Y
5 AMI METER 1"C, 1-2/C AND 1-4/C CABLE TO EF 112 VIA CABLE TRAY. COIL 20 FEET
OF SLACK IN CABLE TRAY IN EF 112.
STAIR
S01
STAIR
S02
STAIR
S05
STAIR
S04
STAIR
S03
LAUNDRY
CORR
ACTIVITY
UNIT
U101
UNIT
U103
UNIT
U104
UNIT
U106
RECYCLE
VEST
VEND
JAN
MECH
EF
ELEC
CQ
MECH
ACCESS
105C
MAILROOM
D
C
B
A
2 3 4 5 6 7 8
TYPICAL FOR NORTH SIDE
T-451
T-451
TYPICAL FOR SOUTH SIDE
D4
T-452
ROOM, SEE
FOR WORK IN THIS
C
C
C
C
C
C
C
C
JJ
D D
D D
D
D
E
24 T 4 E
1 C 2
N4X JB
18" x 18" x 6"
E
J
SCT (18")
M
D
AMI METER
ELECTRICAL
CT (12")
PANEL
DDC
C T
48" x 60" x 24" N4X, SS JB
16" x 12" x 6"D JB
TRAY TRANSITION
JUNCTION BOX TO CABLE
SEE DETAIL FOR
D6
T-510
A
D
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S
O P
T
IO
N
H O
F
IE
L D B
A R
R A
C K
S
O A
H U
H A
W A
II
F Y Q
U A
D A R
E P
A
IR
B
L D
G S
A
N D
N O
L U
L U
H I
H O
N O
L U
L U E
N G
IN
E E
R D
IS
T R
IC
T
R E
G
IO
N A
L E
N G
IN
E E
R
IN
G C
E N
T E
R
H O
N O
L U
L U D
IS
T R
IC
T
F T S
H A
F T
E R
H A
W A
II
F
IL
E N
A M
E
M
IT
C H
E L L N
A G
A T
A
M K E
N G
IN
E E
R S L T
D
P A
U L K
U Y
E D
A
J U
N E
RTA
M K E
N G
IN
E E
R S L T
D
SCALE: 1/8"=1'-0"
PLAN
NORTH
KEY PLAN
0 8'4'
| M - FY18 Quad A Repair Bldgs 130 and 132, AM-0001 Drawings |
| M-661 |
| 18037_B130_ELEC_Y190726_Amd1 |
| 18037_B132_ELEC_Y190726_Amd1 |
File details come from the government source that posted it.