W9128A-19-R-0014_Drawings_-_Package_1_(Part_10_of_11).pdf

PDF 10 MB Posted

Attached to
Quad A, Building 131 and Central Utility Plant (CUP), and Buildings 130 and 132, Schofield Barracks, Hawaii
Solicitation number
W9128A-19-R-0014
Issued by

About this file

W9128A-19-R-0014 Drawings - Package 1 (Part 10 of 11)

View the file

Other files

File Type Posted
W9128A-19-R-0014_-_Section_00_22_16,_Attachment_A.docx DOCX document
W9128A-19-R-0014_Am-0007_Drawings_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0007_Drawings_-_Package_2.pdf PDF
W9128A-19-R-0014_Am-0007_Specifications_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0007.pdf PDF
W9128A-19-R-0014_Am-0006.pdf PDF
W9128A-19-R-0014_Am-0006_Drawings_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0006_Drawings_-_Package_2.pdf PDF
W9128A-19-R-0014_Am-0005.pdf PDF
W9128A-19-R-0014_Am-0004_Specifications_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0004_Drawings_-_Package_2.pdf PDF
W9128A-19-R-0014_Am-0004.pdf PDF
W9128A-19-R-0014_Am-0004_Drawings_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0003.pdf PDF
W9128A-19-R-0014_Am-0002.pdf PDF
W9128A-19-R-0014_Am-0001_Specifications_-_Package_1.pdf PDF
W9128A-19-R-0014_Am-0001_Drawings_-_Package_2_(Part_1_of_2).pdf PDF
W9128A-19-R-0014_Am-0001_Specifications_-_Package_2.pdf PDF
W9128A-19-R-0014_Am-0001_Drawings_-_Package_2_(Part_2_of_2).pdf PDF
W9128A-19-R-0014_Am-0001.pdf PDF
W9128A-19-R-0014_Am-0001_Drawings_-_Package_1.pdf PDF
W9128A-19-R-0014_Request_for_Proposal.pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_11_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_6_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_1_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_5_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_13_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_11_of_14).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_1_(Part_3_of_3).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_2_(Part_3_of_3).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_7_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_12_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_9_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_3_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_4_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_10_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_2_of_11).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_1_(Part_2_of_3).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_2_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_8_of_11).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_2_(Part_2_of_3).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_7_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_14_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_6_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_3_of_11).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_1_(Part_1_of_3).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_9_of_11).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_2_(Part_1_of_14).pdf PDF
W9128A-19-R-0014_Drawings_-_Package_1_(Part_4_of_11).pdf PDF
W9128A-19-R-0014_Specifications_-_Package_2_(Part_1_of_3).pdf PDF
Show 40 more

Latest 50 of 52 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TO EXCEED 4 FEET.

LENGTH TO SUIT, BUT NOT

3/4" CONDUIT HANGAR STEM,

IN ALL DIRECTIONS, TYPICAL

SWIVEL FROM PERPENDICULAR

BALL ALIGNER, MIN. 45°

CAST METAL J-BOX WITH

ROOF LINE

LENGTH TO SUIT

1-5/8" X 1-5/8", GALVANIZED FINISH

MINIMUM STEEL WITH

CHANNEL IRON, 12 GAUGE

TYPICAL

COUPLING,

LUMINAIRE (1-4')

LED

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

H O

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W A

II

R E

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

I

S

C H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

N

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

T

F

IL

E N

A M

E

1:37:35 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EL402.dgn.dgn

J U

N E

RTA

P T

IO

N A

L V

A L

U E s b -B

E

L .d g n

EL402

L E

C T

R

IC

A L M

O U

N T

IN

G D

E T

A

IL

PLANS

AS INDICATED ON

MOUNTING HEIGHT

TO SUIT

FEED-IN STEM. LENGTH

3/4" CONDUIT POWER

ON PURLIN

J-BOX MOUNTED

ADJACENT LUMINAIRE

3/4" CONDUIT TO

METAL CONDUIT

3/4" FLEXIBLE

A1

MOUNTING DETAIL

NOT TO SCALE

T H

M L

B

K A

M I

M L

A M

BLDG 131

W A

Y N

E H

H A

N A

O K

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:37:36 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EL501.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

L .d

EL501

L

IG

H T

IN

G F

IX

T U

R E D

E T

A

IL

S

BLDG 131BLDG 131

TYPE A

TYPE A1

FEATURES

GENERAL DESCRIPTION

TYPE B

LAMP TYPE: LED

50 WATTS. LINEAR SUSPENDED LED FIXTURE

BATTERY PACK

50 WATTS. LINEAR SUSPENDED LED FIXTURE, W/ EMERGENCY

CCT: 3500K

CRI: 80 MIN

GENERAL DESCRIPTION

LUMENS: 5600

FINISH: WHITE OR PAINTED ALUMINUM

OVERALL SUSPENSION: PENDANT/CHAIN

ELECTRICAL: 277 VOLT BALLAST

CCT: 3500K

CRI: 80 MIN

ELECTRICAL: 277V

CCT: 3500K

CRI: 80 MIN

LUMENS: 4000

MOUNTING: SURFACE

HOUSING: HOUSING FORMED FROM COLD ROLLED STEEL

NOM. DIMENSIONS 2' W X 2' L X 4-3/4" D

ELECTRICAL: 277V

TYPE C

TYPE C1

TYPE D

TYPE D1

TYPE E

TYPE E1

TYPE F

35 WATTS. 2' X 2' LED SURFACE MOUNT

BATTERY PACK

35 WATTS. 2' X 2' LED SURFACE MOUNT, W/ EMERGENCY

31 WATTS. 2' X 4' LED RECESSED MOUNT

CCT: 3500K

CRI: 80 MIN

LUMENS: 4000

FINISH: PAINTED WHITE

LAMP TYPE: LED

CCT: 3500K

CRI: 80 MIN

LUMENS: 4000

32 WATTS. 4' LED WRAPAROUND

BATTERY PACK

32 WATTS. 4' LED WRAPAROUND, W/ EMERGENCY

NOM. DIMENSIONS 4' L X 8-5/8" W X 2-5/8" D

HOUSING: DIE-FORMED FROM COLD GAUGE COLD-ROLLED STEEL

MOUNTING: SURFACE

FINISH: WHITE ENAMEL ENDPLATES

LAMP TYPE: LED

CCT: 3500K

CRI: 80 MIN

LUMENS: 3000

35 WATTS. 4" WALL WASH LED

NOM. DIMENSIONS 4" DIAMETER

HOUSING: GALVANIZED STEEL MOUNTING/PLASTER FRAME

MOUNTING: RECESSED

ELECTRICAL: 120V OR 277VELECTRICAL: 120V OR 277V

BATTERY PACK

31 WATTS. 2' X 4' LED RECESSED MOUNT, W/ EMERGENCY

FINISH: MATTE WHITE POWDER PAINT

HOUSING: 22-GAUGE POWDER-PAINTED STEEL

NOM. DIMENSIONS 2' W X 4' L X 3" D

31 WATTS. 2' X 2' LED RECESSED MOUNT

LUMENS: 4000

NOM. DIMENSIONS 2' W X 2' L X 3" D

HOUSING: 22-GAUGE POWDER-PAINTED STEEL

MOUNTING: RECESSED

MOUNTING: RECESSED

FINISH: MATTE WHITE POWDER PAINT

TYPE B1

BATTERY PACK

31 WATTS. 2' X 2' LED RECESSED MOUNT, W/ EMERGENCY

MOUNTING: SUSPENDED MOUNT 9' AFF

NOM. DIMENSIONS 6-1/2" W X 4' L X 4" D

HOUSING: 100% UV STABILIZED POLYCARBONATE

NOTE: SUITABLE FOR DAMP LOCATION

DIFFUSER:

STANDARD T-BARTRIM:

EXTRUDED ACRYLIC DIFFUSER LINEAR

PRISMATIC LENS BACKED WITH ACRYLIC

OVERLAY

DIFFUSER:ACRYLIC PRISMATIC LENS

DIFFUSER:

STANDARD T-BARTRIM:

EXTRUDED ACRYLIC DIFFUSER LINEAR

PRISMATIC LENS BACKED WITH ACRYLIC

OVERLAY

DIFFUSER:ACRYLIC PRISMATIC LENS

FINISH: WHITE

LENS: PARABOLIC REFLECTOR, CONVEXED LENS

B

K A

M I

W A

Y N

E H

H A

N A

O

M L

A M

M L

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

2:30:40 PM7/11/2019

pw:\\COE-POHPWP08FTS.poh.ds.usace.army.mil:coe-pohpwp08fts.poh.ds.usace.army.mil\Documents\Military\02 SB\Projects\2018\18sb04 - FY19 OMA REPAIR QUAD A, BLDG 131 AND CENTRAL UTILITY PLANT, SB\02 Engineering Design\02 Plans and Specs\CAD_BIM\CADFiles\K-Ele

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

L .d

EL502

BLDG 131BLDG 131

L

IG

H T

IN

G F

IX

T U

R E

S D

E T

A

IL

S

PATTERN: 360 DEGREE

COVERAGE: 46-186 SQ M (500-2000 SF)

TIME DELAY: ADJUSTABLE 15 SEC TO 15 MIN

TECHNOLOGY: DUAL PASSIVE IR/ULTRASONIC

NOM. DIMENSIONS 4-1/2" DIA X 1-1/4" D

HOUSING: IMPACT RESISTANT INJECTION MOLDED ABS

MOUNTING: CEILING

FINISH: WHITE

TYPE KTYPE J

NOM. DIMENSIONS 11-3/8" W X 7-7/8" H X 1-3/4" D

WITH 19 mm (3/4") STROKE. DIRECTIONAL ARROWS AS REQUIRED

HOUSING: THERMOPLASTIC HOUSING, 152 mm (6") H LETTERS

ELECTRICAL: 277V

FINISH: WHITE

SHIELDING: FLAT SHEET ACRYLIC

LAMP TYPE: LED

FEATURES

OCCUPANCY SENSOREXIT SIGN

TYPE I

NOM. DIMENSIONS 12" L X 2.8" W X 1" H

MOUNTING: UNDERCABINET

ELECTRICAL: 120V

FINISH: WHITE

CCT: 3000K

CRI: 90 MIN

LUMENS: 388

LAMP TYPE: LED

TYPE H

CCT: 4000K

CRI: 90 MIN

LUMENS: 1300

NOM. DIMENSIONS 2' L X 5" W X 4" D

REFLECTORS: ACRYLIC DIFFUSER

ELECTRICAL: 120V AND 277V

FINISH: BRUSHED NICKEL, CHROME, OR BRONZE

TYPE G 26 WATTS. 2' TRADITIONAL SQUARE VANITY 6 WATTS. 12" LED UNDERCABINET10 WATTS. 4" DIA RECESSED LED DOWNLIGHT

FEATURES

LAMP TYPE: LED

GENERAL DESCRIPTION

MOUNTING: RECESSED

CCT: 3500K

CRI: 80 MIN

LUMENS: 740

ELECTRICAL: 120 OR 277V

NOM. DIMENSIONS 4" DIAMETER, 1" DEPTH

FINISH: MATTE WHITE

HOUSING: ALUMINUM DIE CAST OUTER FRAME. DURABLE, POWDER COAT PAINT

TO PREVENT RUST

TYPE L

CCT: 4000K

CRI: 85 MIN

LUMENS: 575

NOM. DIMENSIONS 4-1/4" H X 6-5/8" W X 1-5/8" D

HOUSING: FEATURES A WHITE ACRYLIC DIFFUSER WITH A PULL CHAIN

ELECTRICAL: 120V

FINISH: WHITE

10 WATTS. LED CLOSET LIGHT

NOTE: WET LOCATION LISTED (WP - WEATHERPROOF)

MOUNTING: WALL MOUNT 87" AFF. CENTERED ABOVE MIRROR.

MOUNTING: WALL MOUNT 7' AFF, ADJACENT TO CLOSET DOOR.

MOUNTING: CEILING

HOUSING: LOW PROFILE DESIGN, WITH ON/OFF ROCKER SWITCH. DIRECT WIRED.

LOW-PROFILE STEEL HOUSING.

HOUSING: CHROME

DIFFUSER: ALUMINUM REFLECTOR, DIFFUSED LENS DIFFUSER: EXTRUDED ACRYLIC DIFFUSER

LETTERS: RED

DIFFUSER: WHITE ACRYLIC DIFFUSER

DIFFUSER: WHITE ACRYLIC DIFFUSER

T H

M L

B

K A

M I

M L

A M

W A

Y N

E H

H A

N A

O K

ELECTRICAL: 24V (LOW VOLTAGE)

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:37:38 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EL503.dgn

J U

N E

EL503

P T

IO

N A

L V

A L

U E

CCT: 3500K

CRI: 80 MIN

GENERAL DESCRIPTION

INDIRECT/DIRECT INTENSITY RATIO: 20% UP/80% DOWN

OVERALL SUSPENSION: 48" ADJUSTABLE

NOM. DIMENSIONS 11-3/8" W X 7-7/8" H X 1-3/4" D

LUMENS: 10,000

BATTERY PACK

80 WATTS. LED SUSPEND MOUNT, W/ EMERGENCY

HOUSING: FIBERGLASS HOUSING

NOM. DIMENSIONS 6.8" W X 4' L X 4.2" D

FINISH: WHITE

CCT: 4000K

CRI: 70 MIN

LUMENS: 1650

12 WATTS. LED WALL SCONCE

HOUSING: DIE CAST ALUMINUM HOUSING

FINISH: EXTERIOR PARTS ARE PROVIDED WITH A ZINC INFUSED COAT

FINISH THAT PROVIDES RESISTANCE TO CORROSIONG AND WEATHERING.

BLACK FINISH.

CCT: 4000K

CRI: 80 MIN

ELECTRICAL: 120V OR 277V

ELECTRICAL: 120V OR 277V

LUMENS: 4,470

HOUSING: RUGGED CAST-ALUMINUM HOUSING WITH BRONZE POLYESTER POWDER PAINT

FOR LASTING DURABILITY

NOM. DIMENSIONS 12 15/16" W X 9" H X 7 1/2" D

FINISH: TEXTURED DARK BRONZE

30 WATTS. LED WALL MOUNTTYPE OTYPE N

TYPE P

TYPE M1

CCT: 3500K

CRI: 80 MIN

GENERAL DESCRIPTION

NOM. DIMENSIONS 2' W X 2' L X 1-1/2" D

LUMENS: 3600 - 3900

HOUSING: LUMINAIRE HOUSING AND END CAPS ARE DIE FORMED CODE GAUGE

COLD ROLLED STEEL

FINISH: REFLECTIVE GLOSS BAKED ENAMEL

NOTE: DOES NOT INTRUDE INTO USABLE PLENUM SPACE

ELECTRICAL: 277V

35 WATTS. 2' X 2' ZERO PLENUM TROFFER

CCT: 3500K

CRI: 80 MIN

GENERAL DESCRIPTION

NOM. DIMENSIONS 4 3/4" DIA. X 7 7/8" H

LUMENS: 1000 - 2000

ELECTRICAL: 277V

TYPE Q

FINISH: NATURAL ALUMINUM

HOUSING: DIE CAST ALUMINUM

10 WATTS. WALL MOUNTED COMPACT LED AREA LIGHT

CCT: 3500K

CRI: 80 MIN

GENERAL DESCRIPTION

LUMENS: 4000 - 4500

MOUNTING: SURFACE

TYPE R 45 WATTS. VANDAL RESISTANT/HIGH ABUSE LED

NOM. DIMENSIONS 8.5" W X44" L X 4" D

FINISH: HIGH GLOSS, WHITE POWDER COAT FINISH, AVERAGE MINIMUM REFLECTANCE 92%

NOTE: INCLUDE TAMPERPROOF SCREWS TO PREVENT UNAUTHORIZED ACCESS.

HOUSING: TAMPER-RESISTANT 16 GA POWDER PAINTED STEEL BACKPLATE

NOTE: DAMP LOCATION LISTED

MOUNTING: WALL, 9' AFF

MOUNTING: WALL, 6" ABOVE DOOR

MOUNTING: WALL, 6' AFF, ADJACENT TO DOOR

DIFFUSER: INJECTION MOLDED ACRYLIC LENS DIFFUSER: ACRYLIC LENS DIFFUSER: PRISMATIC GLASS LENS

MOUNTING: RECESSED

DIFFUSER: ACRYLIC LENS DIFFUSER: ACRYLIC LENS DIFFUSER: TAMPER-RESISTANT, INJECTION-MOLDED

POLYCARBONATE REFRACTOR

L

IG

H T

IN

G F

IX

T U

R E D

E T

A

IL

S

TYPE M1 80 WATTS. LED SUSPEND MOUNT

MOUNTING: SUSPENDED, 11' AFF

s b -B

E

L .d g n

BLDG 131

M L

A M

T H

M L

B

K A

M I

W A

Y N

E H

H A

N A

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:37:39 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EL601.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

L .d

EL601

L

IG

H T

IN

G C

O N

T R

O L D

IA

G R

A M

BLDG 131BLDG 131NTSA4

NTSA1

CONTROL DIAGRAM (RECREATION COURT)

S

ROW

FRONT

2 ROWS

BACK

ROW

FRONT

2 ROWS

BACK

ENTRANCE

LIGHT SWITCH

ENTRANCE

LIGHT SWITCH

1P-20A

SWITCH AT COURT

3P-30A

277 V COIL

1P-20A, 277V

6PM TO 10PM

TC

TC CONTACTOR

N

GREEN

GROUND

EARTH

NEUTRAL WHITE

UNSWITCHED

120/277

HOT BLACK

NO SCALE

COUPLER

1.

NOTES:

2.

WALL SWITCH

DIMMING

DIGITAL

IF APPLICABLE

(CORNER MOUNTED)

SENSOR

DIGITAL OCCUPANCY

WALL SWITCH

DIMMING

DIGITAL

D

CONTROLLER

DIMMING ROOM

D

D

DIGITAL OCCUPANCY SENSOR WITH DIMMING WIRING DIAGRAM

RC

D1

MOUNTED)

SENSOR (CEILING

OCCUPANCY

DIGITAL

HOT

#5

#6TEST

EMERGENCY

SET

UTILITY

STATUS #7

NORMAL HOT

NORMAL NEUTRAL

#4

#3

#13

#12

#10

#8#1

4-WIRE DIMMABLE LOADS

SW HOT

NEUTRAL

NORMAL HOT

NORMAL NEUTRAL

LOAD

GRAY

PURPLE

PURPLE

G R

A Y

SEE

ROOM CONTROLLER,

EXIT SIGN

NO SCALE

1.

NOTES:

2.

D6

EMERGENCY LIGHTING CONTROL UNIT WIRING DIAGRAM

CONTROLLER

DIMMING ROOM

TO ADDITIONAL

CONTROL UNIT

TO EMERGENCY LIGHTING

CABLE

RECOMMENDED

MANUFACTURE

SWITCHED HOT

0-10V CONTROL WIRING

PURPLE AND GREY CLASS 2

OTHERS

PROVIDED BY

CONTROL MODULE

FA DRY CONTACT

RC

UPON ACTIVATION OF THE FA SYSTEM, THE CONTROL UNIT SHALL TURN ON ALL LIGHT TO FULL BRIGHTNESS.

FA CONTROL MODULE PROVIDED BY OTHERS.

LIGHT TO CHARGE THE BATTERY PACK.

ALTHOUGH NOT SHOWN, THE EMERGENCY ALWAYS ON LINE SHALL BE RUN TO THE SWITCHED EMERGENCY

3.

70 725.48.

CLASS 2 0-10V WIRING SHALL BE IN CONDUIT. CONTROL CABLING INSTALLED IN CLASS 1 CONDUIT SHALL COMPLY WITH NFPH

OF OPERATION.

PROVIDE ADDITIONAL ROOM CONTROLLER TO SUPPLY THE NUMBER OF LIGHTING LOADS AS INDICATED ON THE SEQUENCE

CLASS 2 0-10 VOLT CONTROL WIRING ONLY REQUIRED FOR DIMMING FIXTURES.

COORDINATE ALL WIRING REQUIREMENTS WITH MANUFACTURER.

WALL WASH

NEAR PODIUM

(WITH DIMMER)

LIGHT SWITCH

NEAR PODIUM

(WITH DIMMER)

LIGHT SWITCH

RECESSED LIGHTS

LIGHT SWITCHES - CONFERENCE ROOM

OS

OS

D1

EL601

T H

M L

B

K A

M I

M L

A M

CKT 14B-2

SEE PANEL

NTSA8

PHOTOCELL WIRING DIAGRAM

N

PHOTOCELLLOAD

NEUTRAL

LIVE

L0

L1

W A

Y N

E H

H A

N A

O

211661

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:37:50 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP104.dgn

J U

N E

GFCI

GFCI

GFCI

GFCI

GFCI

1/4"=1'-0" A1

FIRST FLOOR POWER PLAN - ADMINISTRATION WINGS

EP403

E1

10 12

12 10

11 6 8

8 6

6 8

6 6

112E1-5,7

112E1-10,12

112E1-17

112E-2

112E1-9,11

112E1-22

112E1-24 112E1-16

112E1-18

112E1-20

112E1-2,4

112E1-1,3

112E-4

112E1-14

112E1-13,15

112E1-19

112E-2

112E1-21

EP406

E1

112E-12

112E1-16

112E1-19

112E-9,11,13

7-#12,#12 GND,3"C

112E1-6,8

112E-3

112E-1

112E-10

112E-6

208/120V,3�,4W

PNL 112E1480/277V,3�,4W

PNL 114E

208/120V,3�,4W

PNL 112E

208/120V,3�,4W

PNL 112E2

112E1-23

KEY PLAN

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EP104

IR

S T F

L O

O R P

O W

E R P

L A

N

MATCH LINE A - SEE EP105

4' 8'0 2'

SCALE: 1/4"=1'-0"

A D

M

IN

IS

T R

A T

IO

N W

IN

G

S

BLDG 131BLDG 131

PLAN

NORTH

KEY NOTES:

T H J

K

B

K A

M I

B

K A

M I, J

K R

O O

K

9 9

FLOOR MOUNTED RECEPTACLE POP UP TYPE.

EQUIPMENT.

COORDINATE RECEPTACLE LOCATION AND HEIGHT WITH

RECEPTACLE TO PROVIDE POWER FOR ELECTRIC WATER COOLER.

PAVILLION.

PROVIDE NEMA 4X JB. INTERCEPT EXISTING CIRCUITS FEEDING

EQUIPMENT.

CEILING MOUNTED RECEPTACLE FOR PROJECTOR/AUDIOVISUAL

DEDICATED RECEPTACLE FOR AUDIOVISUAL EQUIPMENT.

FOR TV.

MOUNT RECEPTACLE AT 60" AFF. DEDICATED RECEPTACLE

NOT LOSE POWER WHEN UPSTREAM GFCI RECEPTACLES TRIP.

WIRE CONDUIT TO ENSURE DOWNSTREAM RECEPTACLES DO

SCREEN.

PROVIDE POWER FOR CEILING MOUNTED PROJECTOR

DRAWINGS.

MOUNT RECEPTACLE 6" ABOVE TILE. SEE ARCH.

6" OF A POWER RECEPTACLE. SEE TELECOM DRAWINGS.

TELECOM OUTLETS SHALL BE LOCATED WITHIN1.

NOTES:

W A

Y N

E H

H A

N A

O K

A

E CD B A

CO

CORR

STOR

XO

1SG

TRAINING

TR

PLATOON

CORR

CMD CONF

PLATOON

PLATOON

PLATOON

NBC

COMM

CORR

ARMS VAULT

UNIT STOR

STOR

SECURE

JAN

WOMEN

MEN

SHWR

MEN

SHWR

WOMEN

TOILET

ELEC

N W P

R T

J

SM

SM

SM

SM

SM

SM

E

E

E

E

E

E

E

E

SM

SM

E

ESM

E

SM

E

SM

E

SM

E

SM

SM

E

SM

E

J

SM

EF

131-1

EF

131-3

J

VAV

131-4

VAV

131-3

VAV

131-2

VAV

131-1

VAV

131-5

VAV

131-6

VAV

131-7

VAV

131-8

131-10

VAV VAV

131-11

VAV

131-12 VAV

131-13

VAV

131-15

VAV

131-14

E

VAV

131-9

SM

211661

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:37:53 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP105.dgn

J U

N E

RTA

G F

C I

1/8"=1'-0" A1

EP401

EP408

A1

FIRST FLOOR POWER PLAN - UEPH

EP402

A1

PLAN

NORTH

0 8'4' 16'

M A

T C

H L

IN

E A S

E E E

P

M A

T C

H L

IN

E B S

E E E

P

BLDG 131

112C-16

112C-18

112C-14

480Y/277V,3Ø,4W

PANEL 1MDP

SEE TYP UNIT PLAN

U E

P H

F

IR

S T F

L O

O R P

O W

E R P

L A

N

EP105

208Y/120V,3Ø,4W

PANEL 112B

208Y/120V,3Ø,4W

PANEL 112C

208/120V,3�,4W

PANEL 112E

208Y/120V,3Ø,4W

PANEL E

s b -B

E

P .d g n

208Y/120V,3Ø,4W

PANEL 112A

6" OF A POWER RECEPTACLE. SEE TELECOM DRAWINGS.

TELECOM OUTLETS SHALL BE LOCATED WITHIN1.

NOTES:

J

K R

O O

K

T H

B

K A

M I

W A

Y N

E H

H A

N A

O K

A

CORR

ELEC

STORAGE

MECHANICAL

RECYCLE

UNIT

U101

UNIT

U102

UNIT

U104

UNIT

U103

UNIT

U108

UNIT

U107

UNIT

U110

UNIT

U109

UNIT

U106

B

C

D

E

MECHANICAL

STORAGE

RECYCLE

6 7 8 9 10 11 12 13 14 15 16

NW PRT

J s s s s ss ss

CKT CKT BKR BKR CKT CKT

NO. POLE AMP AMP POLE NO.

12 12 1 FCU‐1 1 20* 1.0 1.0 20* 1 FCU‐2 2 12 12

12 12 3 BED RM A RECEPT 1 20* 1.1 1.1 20* 1 BED RM B RECEPT 4 12 12

12 12 5 BED RM A RECEPT 1 20* 1.0 1.1 20* 1 BED RM B RECEPT 6 12 12

12 12 7 LIVING RM RECEPT 1 20* 1.1 1.1 20* 1 KITCHEN RECEPT 8 12 12

12 12 9 GARBAGE DISP 1 20* 1.1 1.1 20* 1 KITCHEN RECEPT 10 12 12

12 12 11 DOOR BELL 1 20* 0.5 1.1 20* 1 COOR/ BATH 12 12 12

12 12 13 REFRIG 1 20* 1.2 1.2 20* 1 RANGE HOOD 14 12 12

12 12 15 LIGHTING 1 20* 1.0 1.0 20* 1 S 16

17 PFB PFB 18

19 PFB PFB 20

21 PFB PFB 22

23 PFB PFB 24

25 PFB PFB 26

27 PFB 4.0 50 2 RANGE 28 8 10

29 PFB 4.0 ‐‐ ‐‐ 30 8 10

31 32 33 34 35 36 37 38 39 40 41 42

CONNECTED LOAD/PHASE NOTES: * AFCI BREAKER

TOTAL CONNECTED LOAD KVA

DEMAND FACTOR

TOTAL DEMAND LOAD KVA

DEMAND AMPS AMPS

17.3 48.1

12.7 11.9 24.6

70.3%

GN

D W

IR

E (A W G)

W

IR

E

SI

ZE

(A

W G) 208Y/120V, 1Ø, 3W

2P70A MAIN BRKR

100A BSSES

CONNECTED (KVA)USE USE

PHASE A PHASE B W

IR

E

SI

ZE

(A

W G)

TYP PNL UEPH

MIN A.I.C.

MOUNTING: RECESSED

GN

D W

IR

E (A W G)

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:07 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP402.dgn

J U

N E

RTA

J

J

A1 1/2"=1'-0"

114A

TRANSFORMER

480Y/277V,3Ø,4W

PANEL 1MDPCT CAB

114A

TRANSFORMER

METER

CT CAB

FLR FLR

CONT. ON SITE PLAN

FLR

GND BUS

A B C

D

ENLARGED ELECTRICAL PLAN AND ELEVATIONS (ELEC RM 138)

112C-25

RECEPT

FLR

208/120V,3Ø,4W

PANEL E

208Y/120V,3Ø,4W

PANEL 112C

METER

PAD

4" CONC HOUSEKEEPING

VIBRATION ISOLATION

DOOR

PAD

4" CONC HOUSEKEEPING

VIBRATION ISOLATION

TRANSFORMER E

GND BUS

208/120V,3Ø,4W

PANEL 112

PANEL 1MDPPANEL 112PANEL 112C

PANEL E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EP402

KEY

EL

INT

A

B

C

D

0 2' 4'1'

KEY NOTES:

1.

NOTES:

E N

L A

R G

E D E

L E

C T

R

IC

A L P

L A

N A

N D E

L E

V A

T

IO

N S

BLDG 131BLDG 131

(E L E

C R

M

P

O W

E R P

L

TO PANEL 112B.

FOR CONT.

MTD IN CRAWLSPACE. SEE DISTRIBUTION PLAN

MATCH EXST.

SAW CUT FLOOR TO INSTALL WIRING. REPAIR TO

WIRING PER ONE-LINE DIAGRAM.

NOT ALL WIRING, EQUIPMENT DEVICES INDICATED FOR CLARITY.

T H J

K

B

K A

M I

B

K A

M I, J

K R

O O

K

W A

Y N

E H

H A

N A

O K

A

E

ELEC

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:08 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP403.dgn

J U

N E

RTA

A1 1/2"=1'-0"

1/8"=1'-0" E1

208/120V,3Ø,4W

PANEL 112E

480/277V,3Ø,4W

PANEL 114E

208/120V,3Ø,4W

PANEL 112W

480/277V,3Ø,4W

PANEL 114W

TRANSFORMER 114W

TRANSFORMER 114E

208/120V,3Ø,4W

PANEL 112E1

208/120V,3Ø,4W

PANEL 112W1

ENLARGED ELECTRICAL PLAN AND ELEVATIONS ELEC (143) POWER PLAN

ENLARGED ELECTRICAL PLAN AND ELEVATIONS ELEC (125) POWER PLAN

112W-19

A B C D

A B C D

114E

TRANSFORMER

208/120V,3Ø,4W

PANEL 112E

208/120V,3Ø,4W

PANEL 112E1

480/277V,3Ø,4W

PANEL 114E

RECEPT

114E

TRANSFORMER

112W-21 208/120V,3Ø,4W

PANEL 112W

208/120V,3Ø,4W

PANEL 112W1

114W

TRANSFORMER

114W

TRANSFORMER

480/277V,3Ø,4W

PANEL 114W

RECEPT

112E-5

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EP403

EL

INT

A

B

L A

R G

E D E

L E

C T

R

IC

A L P

L A

N A

N D E

L E

V A

T

IO

N S

(E L E

C

E

L E

C

P

O W

E R P

L A

N

BLDG 131BLDG 131

0 2' 4'1'

T H J

K

B

K A

M I

B

K A

M I, J

K R

O O

K

W A

Y N

E H

H A

N A

O K

A

C

C

ELEC

ELEC

SM

E

EF

131-6

EF

131-5

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:10 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP404.dgn

J U

N E

RTA

F E

P

3RD FLR

WDW-

F E

P

A1 1/2"=1'-0"

114A

TRANSFORMER

480Y/277V,3Ø,4W

PANEL 1MDPCT CAB

114A

TRANSFORMER

METER

CT CAB

FLR FLR

CONT. ON SITE PLAN

FLR

GND BUS

ENLARGED ELECTRICAL PLAN AND ELEVATIONS (ELEC RM 138)

112C-25

RECEPT

FLR

208/120V,3Ø,4W

PANEL E

208Y/120V,3Ø,4W

PANEL 112C

TRANSFORMER E

METER

18"x18"x6"

J-BOX

24"x24"x18"

J-BOX

PAD

4" CONC HOUSEKEEPING

VIBRATION ISOLATION

DOOR

PAD

4" CONC HOUSEKEEPING

VIBRATION ISOLATION

TRANSFORMER E

GND BUS

208/120V,3Ø,4W

PANEL 112

PANEL 1MDPPANEL 112PANEL 112C

PANEL E

A1 1/2"=1'-0"

1/2"=1'-0" E1

122A-19

132A-19

208/120V,3Ø,4W

PANEL 122A

208/120V,3Ø,4W

PANEL 132A

C D

A B

A B

C D

208/120V,3Ø,4W

PANEL 122A

208/120V,3Ø,4W

PANEL 132A

2E-4

2E-6

ENLARGED ELECTRICAL PLAN AND ELEVATION ELEC (303) POWER PLAN

ENLARGED ELECTRICAL PLAN AND ELEVATION ELEC (203) POWER PLAN

J

RECEPT RECEPT

RECEPTRECEPT

RECEPT

RECEPT

RECEPT

RECEPT

120V,1Ø

FEP

120V,1Ø

FEP

FLRFLR

FLR FLR

FLR FLR

FLR FLR

12"x6"x6"

JBOX

12"x6"x6"

JBOX

J

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EP404

EL

INT

A

B

L A

R G

E D E

L E

C T

R

IC

A L P

L A

N A

N D E

L E

V A

T

IO

N S

(E L E

C

E

L E

C

P

O W

E R P

L A

N

BLDG 131BLDG 131

0 2' 4'1'

T H J

K

B

K A

M I

B

K A

M I, J

K R

O O

K

W A

Y N

E H

H A

N A

O K

A

ELEC

D

D

ELEC

ELEC

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:13 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP405.dgn

J U

N E

RTA

T T

T M

G B

A1 1/4"=1'-0"

ENLARGED PLAN AND ELEVATIONS EF (130) POWER PLAN

A A

C D

112D-6,8 112D-3 112D-2,4 112D-5

112D-1

(TYP)RECEPT

208/120V,3Ø,4W

PANEL 112D

208/120V,3Ø,4W

PANEL 112D

112D-7

112D-30

112D-9

TGMB

LT SW

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EL

INT

A

B

C

D

EP405

E N

L A

R G

E D E

L E

C T

R

IC

A L P

L A

N A

N D E

L E

V A

T

IO

N S

(E F

P

O W

E R P

L A

N

BLDG 131BLDG 131

KEY NOTES:

0 2' 4'1'

T H J

K

B

K A

M I

B

K A

M I, J

K R

O O

K

2 1 2 1

3 3 3 3

DISCONNECT.

85W, 120V, 1�, FCU PROVIDED WITH INTEGRAL

MATCH EXST.

SAWCUT FOOR TO INSTALL WIRING. REPAIR TO

MOUNTED TO EQUIPMENT RACK.

DUPLEX RECEPTACLE, RATED 30A, 208V, L6-30R,

RACK. 20A, 120V.

QUAD RECEPTACLE MOUNTED TO EQUIPMENT

W A

Y N

E H

H A

N A

O K

A

E

EF

E

FCU

131-6

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:15 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP406.dgn

J U

N E

RTA

T

TGB

T

TGB

A1 1/2"=1'-0"

E1

TGB

TGB

ENLARGED PLAN AND ELEVATIONS TR (108) POWER PLAN

ENLARGED PLAN AND ELEVATIONS TR (151) POWER PLAN

A B

DC

A B

DC

112E2-3 112E2-1

112E2-5,7

112W2-3 112W2-5,7

112W2-1

208/120V,3�,4W

PANEL 112E2

208/120V,3�,4W

PANEL 112W2

(TYP)RECEPT

(TYP)RECEPT

208/120V,3�,4W

PANEL 112W2

208/120V,3�,4W

PANEL 112E2112E2-2

112W2-2

112E2-11 112E2-9

112W2-11

112W2-9

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EP406

EL

INT

A

B

L A

R G

E D E

L E

C T

R

IC

A L P

L A

N A

N D E

L E

V A

T

IO

N S

(T R

T

R

P

O W

E R P

L A

N

BLDG 131BLDG 131

0 2' 4'1'

KEY NOTES:

1 2

3 3

DISCONNECT.

85W, 120V, 1�, FCU PROVIDED WITH INTEGRAL

MATCH EXST.

SAWCUT FOOR TO INSTALL WIRING. REPAIR TO

MOUNTED TO EQUIPMENT RACK.

DUPLEX RECEPTACLE, RATED 30A, 208V, L6-30R,

RACK. 20A, 120V.

QUAD RECEPTACLE MOUNTED TO EQUIPMENT

T H J

K

B

K A

M I

B

K A

M I, J

K R

O O

K

W A

Y N

E H

H A

N A

O K

A

TR

D

D

TR

E

FCU

131-5

E

131-4

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:19 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP407.dgn

J U

N E

RTA

A1 1/2"=1'-0"

1/2"=1'-0" E1

ENLARGED PLAN AND ELEVATIONS TR (206) POWER PLAN

ENLARGED PLAN AND ELEVATIONS TR (306) POWER PLAN

B

D

B

D

132B-1

122B-1208Y/120V,3�,4W

PANEL 122B

208Y/120V,3�,4W

PANEL 132B

C

A

C

A

208Y/120V,3�,4W

PANEL 132B

208Y/120V,3�,4W

PANEL 122B

(TYP)RECEPT

(TYP)RECEPT

122B-7

122B-5

122B-3

132B-3

132B-7

132B-5

132B-9

P T

IO

N A

L V

A L

U E s b -B

E

P .d g n

KEY

EL

INT

A

B

EP407

N

L A

R G

E D E

L E

C T

R

IC

A L P

L A

N A

N D E

L E

V A

T

IO

N S

(T R

T

R

P

O W

E R P

L A

N

BLDG 131BLDG 131

0 2' 4'1'

KEY NOTES:

T H J

K

B

K A

M I

B

K A

M I, J

K R

O O

K

DUPLEX RECEPTACLE DEDICATED TO TELECOM RACK.

122B-9

W A

Y N

E H

H A

N A

O K

A

D

D

TR

TR

E

FCU

131-10

E

131-11

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:22 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP408.dgn

J U

N E

RTA

GFCI GFCI

GFCI

GFCIGFCI

GFCI

GFCI

ENLARGED ELECTRICAL PLAN MECH (135) POWER PLAN

112C-20 112C-22

112C-24,26

112C-2

112C-4

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EP408

P

W E

R P

L A

N

E N

L A

R G

E D E

L E

C T

R

IC

A L P

L A

N M

E C

H

BLDG 131BLDG 131

0 2' 4'1'

120V,1�

GAS WATER HEATER GWH-1

120V,1�

GAS WATER HEATER GWH-5

120V,1�

GAS WATER HEATER GWH-4

120V,1�

GAS WATER HEATER GWH-3

120V,1�

GAS WATER HEATER GWH-2

.17HP, 120V, 1�

EF 131-8

T H J

K

B

K A

M I

B

K A

M I, J

K R

O O

K

XHP, 120V, 1�

CIRC PUMP HWRP-131-1

W A

Y N

E H

H A

N A

O K

A

10 11 12

B

MECH

J

J

J

J

J

E

E

E

E

E

SM

SM

SM

SM

SM

ESM

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:23 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP501.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

NTSB3

DUCT (1-WAY CONC ENCASED)

NTSB4

DUCT (2-WAY CONC ENCASED)

NTSB5

DUCT (4-WAY CONC ENCASED)

NTSA3

DUCT (2 WAY DIRECT BURY)

NTSA4

DUCT (4 WAY DIRECT BURY)

NTSA1

DUCT SECTION DB (NON-TRAFFIC AREA)

NTSC1

DUCT SECTION (TRAFFIC AREA)

NTSC3

DUCT SECTION (NON-TRAFFIC AREA)

NTSC4

DUCT SECTION (CONCRETE SIDEWALK)

COMPACTED

BACKFILL

DETECTABLE

WARNING TAPE

1. USE CONDUIT SIZES INDICATED IN

ELECTRICAL SITE PLANS & POWER

SINGLE LINE DIAGRAMS.

NOTE:

EP501

E L E

C T

R

IC

A L D

E T

A

IL

S

M

IN

F

O R S

E C

O N

D A

R Y D

U C

T S

M

IN

F

O R P

R

IM

A R

Y D

U C

T S

TACK COAT @ JOINTS

PROVIDE BITUMINOUS

BACKFILL

COMPACTED

WIDTH VARIES

S E

C O

N D

A R

Y D

U C

T S

M

IN

F

IM

A R

Y D

U C

T S

M

IN

F

COMPACTED BACKFILL

WARNING TAPE

DETECTABLE

GRADE

FINISHED

WARNING TAPE

DETECTABLE

AS INDICATED IN PLAN

CONCRETE ENCASED CONDUITCOHESIONLESS MATERIAL

OF MAX DENSITY FOR

COHESIVE MATERIAL & 95%

OF 90% OF MAX DENSITY FOR

SUBGRADE CUTS TO A MIN

COMPACT THE TOP 6" OF ALL

D W

G S

E E C

IV

IL

TO MATCH SITE CONDITIONS

NEW 12" THK BASE COURSE OR

12" MIN

TO MATCH SITE CONDITIONS

AC SURFACE COURSE OR

SAW CUT (TYP)

PRIME COAT

SURFACE

EXST AC

EXST BASE COURSE

EXST SUBBASE COURSE

SAW CUT

S E

C O

N D

A R

Y D

U C

T S

M

IN

F

IM

A R

Y D

U C

T S

M

IN

F

SIDEWALK

EXST CONC

CONC SIDEWALK

BASE COURSE

D W

G C

IV

IL

S E

E

COMPACTED BACKFILL

WARNING TAPE

DETECTABLE

SITE PLAN

AS INDICATED ON THE

CONDUIT SIZE & QUANTITY

CONCRETE ENCASED

WIDTH

TRENCH

BLDG 131BLDG 131

12" MIN 12" MIN

2"

2"

DISTRIBUTION PLAN

INDICATED IN THE

AND QUANTITY AS

CONDUCTOR SIZE

CONDUIT WITH

SAND CUSHION

M

IN

F

O R S

E C

O N

D A

R Y D

U C

T S

M

IN

F

O R P

R

IM

A R

Y D

U C

T S

FINISHED GRADE

WIDTH VARIES

(SIZE AS REQ'D)

PVC CONDUIT

DUCT AS INDICATED IN PLAN

CONCRETE ENCASED

2"

3"3"

3"

2"

3"3

3"

3"3

T H

B

K A

M I

B

K A

M I

W A

Y N

E H

H A

N A

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:24 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP502.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

NTSD1

TRANSFORMER (FRONT ELEVATION)

NTSD5

TRANSFORMER PAD

NTSA1

TRANSFORMER SECTION A-A

NTSA5

TRANSFORMER SECTION B-B

G G

DANGER

HIGH VOLTAGE

KEEP OUT

G G

G G

G G

G G

G G

(B

"B"

"A"

"B"

"A"

TRANSFORMER

TANK

COOLING FINS

(RADIATOR)

IF EQUIPPED

X1 X3

X0 X2

G

G

G

N

N

G

G G

G G

G

G G

G

N

EP502

E L E

C T

R

IC

A L D

E T

A

IL

S

BLDG 131BLDG 131

NAME PLATE

TRANSFORMER

RELIEF DEVICE

PRESSURE

OIL FILL PLUG

BUSHINGS (TYP)

SPADE TYPE

YELLOW) SEE NOTE 3

SIGN (REFLECTIVE PAINT

STENCILED WARNING

TRANSFORMER WIDTH (A)

T R

A N

S F

O R

M E

R H

E

IG

H T

C

PAINT YELLOW)

RATING (REFLECTIVE

STENCILED KVA

IF EQUIPPED

(RADIATOR

COOLING FINS

PAINT YELLOW)

RATING (REFLECTIVE

STENCILED PHASE

EACH WAY

#4 @ 12" T&B

HANDLE

PADLOCKABLE

IF EQUIPPED

(RADIATOR)

COOLING FINS

C O

N C

R E

T E P

A D L

E N

G T

H

L

T R

A N

S F

O R

M E

R D

E P

H T

8"

3"

8"

3"

CONCRETE PAD WIDTH (W)

TRANSFORMER WIDTH (A)

3/4"x10' LG (TYP)

CU CLAD STL,

GROUND ROD,

COMPARTMENT

SECONDARY

COMPARTMENT

PRIMARY

PAD

AROUND CONCRETE

GRAVEL FILL ALL

CONCRETE PAD

TRANSFORMER DEPTH (B)

12"12"

3"

T R

A N

S F

O R

M E

R H

E

IG

H T

H

ENTRANCE

FOR CABLE

OPENING

CONC PAD

LONG (TYP)

3/4"x10'

CU CLAD STL,

GROUND ROD,

CAPACITY

BASED ON XFMR

BARE CU, SIZE

CONDUCTOR,

GROUNDING

IF EQUIPPED

(RADIATOR)

COOLING FINS

GROUND PAD

ON XFMR CAPACITY

BARE CU, SIZE BASED

GROUNDING CONDUCTOR

LIMITING FUSES HOLDERS

BAY-O-NET CURRENT

TAP CHANGER

PARKING BRACKET (TYP)

BUSHING (TYP)

LOAD-BREAK

(TYP)

SURGE ARRESTER

AS NEUTRAL

SAME WIERE SIZE

BONDING JUMPER

SHIELD GROUNDING

GND WIRE FOR CABLE

#2 AWG BARE CU

FOR CABLE ENTRANCE

CONCRETE PAD OPENING

TYP

REMOVABLE STANCHION

MIN. BC (TYP)

#3/0 AWG

STANDARDS FOR COLORING CODE.

PER ANSI SPEC 253.1 TO COMPLY WITH OSHA

BARRIER POSTS ARE TO BE PAINTED YELLOW AS

NOTE:

4" MIN. ALL AROUND

M

IN

IM

U M

3000 PSI IN 28 DAYS

CONCRETE BASE

3/4" GALV. BOLT

FOR DRAINAGE

CRUSHED GRAVEL

5" STD. GRC PIPE

BOLTS TO CONTREACTING OFFICER

INSTALLATION. TURN OVER

TO BE REMOVED AFTER

FOR LIFTING THE BOLTS ARE

BOLTS TO ACT AS "HANDLES"

APART FOR SCREWING IN

WELD 2 NUTS (5/8") 180°

WITH CONCRETE

SHALL NOT BE FILLED

CAP 4" STD GALV. PIPE

FINISHED GRADE

NTSA8

REMOVABLE STANCHION DETAIL

(REMOVABLE STANCHION NOT INDICATED FOR CLARITY) (REMOVABLE STANCHION NOT INDICATED FOR CLARITY)

(REMOVABLE STANCHION NOT INDICATED FOR CLARITY)

DRAIN VALVE (SAMLER DEVICE NOT SHOWN)

HANDLE

PADLOCKABLE

BASE

GRAVEL

SPLICE (TYP)

SEAL SPARE CONDUITS. DUCT SEAL CONDUITS WITH CABLES.9.

PER SPEC 33 70 02.

PAD CABLE OPENING SHALL BE FILLED W/ MASONRY GROUT

UPON COMPLETION OF EQUIPMENT INSTALLATION, THE CONCRETE8.

PROTECTIVE CAP ON ALL PARKING STANDS.

PROVIDE 15kv INSULATED PARKING BUSHING W/ INSULATED7.

NORWOOD BROWN, #10045 PER DPW EXTERIOR STANDARDS.

FINISH COLOR FOR OUTDOOR CABINET SHALL BE6.

PAINTED IN THE ENCLOSURES.

PROVIDE DATE OF INSTALLATION OF THE EQUIPMENT TO BE5.

EARTH RESISTAANCE SHALL NOT EXCEDD 5 OHMS.4.

CONSTRUCTION.

USE ACTUAL DIMENSIONS OF MANUFACTURER'S DRAWING FOR

INDICATED DIMENSIONS OF TRANSFORMER IS APPROXIMATE.3.

DETAILS OF THE WARNING SIGN SHALL BE IAW IEEE STD.2.

DELTA PRIMARY AND 480/277V WYE SECONDARY.

THREE PHASE TRANSFORMER SHALL BE RATED 7.2kv/12.47kv1.

NOTES:

SEE SPEC

RADIAL FEED SWITCH,

OIL LEVEL INDICATOR

PRESSURE-VACUUM GAGE

THERMOMETER

SPLICE (TYP)

1/2"

T H

B

K A

M I

B

K A

M I

W A

Y N

E H

H A

N A

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

5:45:45 PM6/26/2019

pw:\\COE-POHPWP08FTS.poh.ds.usace.army.mil:coe-pohpwp08fts.poh.ds.usace.army.mil\Documents\Military\02 SB\Projects\2018\18sb04 - FY19 OMA REPAIR QUAD A, BLDG 131 AND CENTRAL UTILITY PLANT, SB\02 Engineering Design\02 Plans and Specs\CAD_BIM\CADFiles\K-Ele

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

NTSA1

HANDHOLE DETAILS, 2'x4'

EP504

BLDG 131BLDG 131

B1

ES502

NTSD1

PULLING IRON DETAILS

NTSF1

HANDHOLE COVER DETAIL

NTSA4

HANDHOLE SECTIONS DETAIL

D1

EP504

A4

EP504

F1

EP504

7/8" DIA

9"

3"

FINISH GRADE

COVER SEE2

SEE

PULLING IRONS

12" CONC. SECTION SEE

GROUND ROD

3" CONDUIT

SUBBASE 6"

COMPACTED GRAVEL

HH COMPONENTS

GROUND ALL METAL

AROUND

(T

YP.

2#

ALL

3'- 8 3 /4"

1'-9 1/4"

4'- 0"

2' - 1/2"

1'-9 5/16"

3'- 8 7 /8"

1 5/8"

1 5/8"

1'-9 3/8" 4'-

0"

3'- 9 1 /8"

2' - 1/2"

3 1/16"

T H

B

K A

M I

B

K A

M I

E L E

C T

R

IC

A L D

E T

A

IL

S

AT MINIMUM CONDUIT DEPTH

ACCOMODATE CONDUIT ENTRY

COURSES AS REQUIRED TO

BRICK UNDERLAY, NUMBER OF

2"

8" CONC. SECTION

3/4"

4#3 TRANSVERSE

" FRAME8

12" X 2" X

2#3 LONGITUDINAL

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:27 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP505.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

NTSA1 EP505

PLAN VIEW

SECTION A-A

SECTION B-B

XXXX LBS.

DETAIL A DETAIL B

A B

A

B

DUCT ENTRANCE DUCT ENTRANCE

GROUND ROD

GROUND WIRE

COPPER

#4 AWG BARE

B

A

B

A

48"

78"

78"

UNIFORM BEARING

CEMENT GROUT FOR

WITH DOUBLE NUTS.

STUDS 6" LONG

GROUT

NECKING

W/ GROOVE FOR

6" 78" 6"

90"

6"

48"

6"

60"

8"

6 1/2"

92 1/2"

6" 48" 6"

60"

78"

6 1/2"

8"

92 1/2"

6" 78" 6"

90"

78"

20" 13"4" 16"

24"

30"

24" 18"

7 5/8" 44 3/4" 7 5/8"7 5/8" 74 3/4" 7 5/8"

4"

4" 7 1/2"9"

4"

1 5/8" MIN.

/2

N O

T C

H

18"

18"

12"

4"

18" MAX.

12" MIN.

18"

60"

90"

6 1/2"

8"

6 1/2"

86"

92 1/2"

4 EACH SIDE, 4 SIDES

5" DIA KNOCKOUT

ELECTRICAL MANHOLE (4' x 6') DETAILS BLDG 131BLDG 131

DETAIL A, BELOW

DETAIL B, BELOW

T H

B

K A

M I

B

K A

M I

E L E

C T

R

IC

A L D

E T

A

IL

S

W A

Y N

E H

H A

N A

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:27 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP506.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EP506

A1

MANHOLE ACCESSORIES

A5

NEUTRAL / GROUND CONNECTION IN MANHOLE

INSULATORS

PORCELAIN

2 1/4"

A A

COVERSUMP FRAME

15"

/2

12"

7/8"

MANHOLE WALL

1/2"

3 1/2"

1/4"

SEAL 600V CABLE

WITH TAPE

600V GROUNDED

NEUTRAL

4/0 BARE COPPER

GROUND

2 1/4"

5"

/2 " 1 /2

2 5/8"R.

13"

3/8"

3"

6"

NOTE:

CABLE RACK DETAIL

PULLING IRON DETAIL

TYPICAL SUMP FRAME

AND COVER DETAIL

BOLTS AND EXPANSION SHIELDS

FASTEN BY MEANS OF 2 1/2"x1/2"1.

COVER HANDLE (2 HANDLES REQUIRED)

NO SCALE NO SCALE

T H

B

K A

M I

B

K A

M I

E L E

C T

R

IC

A L D

E T

A

IL

S

W A

Y N

E H

H A

N A

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:28 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP507.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

EP507

A1 NO SCALE

T H

B

K A

M I

B

K A

M I

E L E

C T

R

IC

A L D

E T

A

IL

S

TYPICAL 3' x 5' HANDHOLE

A8 NO SCALE

PULLING IRON DETAIL

D8 NO SCALE

LIFTING DEVICE DETAIL

F8 NO SCALE

SPACER BAR DETAIL

xxx

1/8"

COVER SLAB SECTION

COVER SLAB PLAN

E L E

C

E L E

C

PLAN

SECTION B-BSECTION A-A

2"

3" 3"2'-10 3/4"

3'-4 3/4"

/2

/2

CONC FILL

15" [ 33.9 FRAME

WELD TO [ FRAME

4#4 STL BARS

2#3 STL. BARS

2-LIFTING DEVICES

SPACER BAR

1/2" x 1/8" x 1"

SPACER BAR

6 5/8" 1'-3" 1'-3" 1'-3"

2"

1'-3" 6 5/8"

6'-2"

LIFTING DEVICE

3/16" 1/8" 1/8" 1/8" 3/16"

7" 7"5'-0"

B

AA

B

/8

/2

/8

/2

LETTERING, MINIMUM

MARKING, 2" HIGH

EMBOSSED (OR ENGRAVED)

OR PAVEMENT

FINISHED GRADE

#4 BARS @ 8" ON CENTER

#4 BARS @ 10" ON CENTER

(TYP)

TESTED TO 3,000 PSI

SHALL BE STRENGTH

CONCRETE WALLS

CLAD GROUND ROD WITH CLAMP

3/4"Ø x 10'-0" SECTIONAL COPPER

SLOPE FLR DN 1/2" TO SUMP

#4 BARS @ 10" ON CENTER

SUMP HOLE

12" x 12" x 12"D

SEE

PULLING-IN IRON,

7" 1'-0" 7"4'-0"

M

IN

4"

/2

3/8" CONC SLABS

4-PIECE REMOVABLE

#4 BARS @ 10" ON CENTER

SEE

DUCT ENTRANCE,

SEE

PULLING-IN IRON,

(TYP)

TESTED TO 3,000 PSI.

SHALL BE STRENGTH

CONCRETE WALLS

ROD WITH CLAMP

COPPER CLAD GROUND

3/4"Ø x 10'-0" SECTIONAL

SUMP HOLE

12" x 12" x 12"D

ON CENTER

#4 BARS @ 10"

6"

/2

2-1/2"

OR PAVEMENT

FINISHED GRADE

CONC SLABS

4-PIECE REMOVABLE

#4 BARS @ 8" ON CENTER

7"2'-0"1'-0"7"

1'-0 1/4" 1'-0 1/4" 1'-0 1/4"2" 2"

-3 /8

4#3 STL BARS15"[ 33.9 FRAME

2#3 STL BARS

15" [ 33.9 FRAME

1/2" x 1/8" x 1"

SPACER BAR

CORNER (TYP)

1/4" ROUNDED

1/2"

-1 /4

-1 /8 "2"

3"

U.S. STD. THREATD

DRILL & TAP FOR 3/4"

APPLY GREASE TO THREADS

3/4" BRASS PLUG W/ SLOT,

CONC SLAB

TOP OF REMOVABLE

ROUND STOCK

STEEL ROD FROM

1-3/8"Ø x 2-15/16"

15" [ 33.9 FRAME

TO [ FRAME

WELD ALL AROUND

-1 /2

9"

8-3/8"

TIE TO REBARS IN WALL

WALL, TYPICAL

INSTALL AT L OF C

IN WALL

TIE TO REBARS

PULLING-IN ROD

GALVANIZED

7/8" DIAMETER

GLAVANIZE L OR C FRAME, STEEL RODS, AND SPACER BAR ASSEMBLIES AFTER FABRICATION.2.

PROVIDE 2 EACH COVER LIFTING TOOL FOR HANDHOLE.1.

NOTES:

W A

Y N

E H

H A

N A

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:30 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP508.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

TYPICAL 3' x 5' HANDHOLE

A8 NO SCALE

PULLING IRON DETAIL

7'-8"

3-3/4"

1'-5 9/16" 1'-6 3/4"1'-6 3/4" 1'-6 3/4"

1/8"CLR

MAX

3/16"

CLR

MAX

3/16"

1/8"

1'-5 9/16"

3-3/4"

C L

R M

A X

/8

/4

C L

R M

A X

/8

/4

/2

8"

E L E

C

E L E

C

E L E

C

E L E

C

E L E

C

"B"

"B"

"A" "A"

7'-0"

6'-0"6" 6"

-0

5"

1'-6" 2-1/2"

2-1/2"

"D"

"D"

"D"

"D"

1'-6.01"

6"

1'-0"

DIA

6"

"F"

"F"

SLOPE 1"SLOPE 1"

C

C

"E""E"

C

"C" "C"

C

PULLING IRONS, TYP

C

EQUAL TO OR LESS THAN 60°.

SLING FLEET ANGLE SHALL BE 3.

UP = 2,800 PSI MINIMUM.

CONCRETE STRENGTH @ INITIAL PICK2.

SECTION.

BEAM SHALL BE USED TO LIFT EACH

4-POINT PICK-UP WITH SPREADER1.

LIFTING NOTES:

1'-5 9/16"4'-8 7/8"1'-5 9/16"

2 3/4"

3 3/4"

2 3/4"

3 3/4" 7'-1/2"

/2

C

C

24"

F

IE

L D V

E R

IF

Y

IRONS

FOR PULLING

1" DIA HOLES

"D" "D"

COVER, SEE

REMOVABLE CONCRETE

"COMM" - TELECOM

"ELEC" - ELECTRICAL

TOP SLAB & COVER LOGO:

(4 PER SECTION)

EQUIVALENT, TYP

P-52SL ANCHOR OR

DAYTON SUPERIOR

4 TON x 4-3/4" LG

DIA x 10'-0" GND ROD

1" DIA HOLE FOR 3/4"

SUMP

GND ROD

3/4" DIA x 10'-0"

1" DIA HOLE FOR

CONC COVERS

REMOVABLE

TYP ALL CORNERS

3/4" CHAMFER

(4 PER SECTION)

P-52SL ANCHOR OR EQUIVALENT, TYP

4 TON x 4-3/4" LG DAYTON SUPERIOR

SEE

CABLE RACK,

WALL REINFORCEMENT, SEE

AT DUCT ENTRANCES, PROVIDE ADDITIONAL1.

NOTES:

C

1'-6"

1'-6"

6"

6"

/2

(4 PER SECTION)

OR EQUIVALENT, TYP

SUPERIOR P-52SL ANCHOR

4 TON x 4-3/4" LG DAYTON

TYP, SEE

JOINT SEALER,

4" DEEP SUMP

7'-0"

3'-4"

C

1'-2" 1'-2"

2 3/4"

3 3/4"

2 3/4"

3 3/4" 5'-0 1/2"

TYP ALL CORNERS

3/4" CHAMFER

CONC COVERS

REMOVABLE

TYP, SEE

JOINT SEALER, C

IRONS

FOR PULLING

1" DIA HOLES

F

IE

L D V

E R

IF

Y

(S

E E W

A L L N

O T

E S

1'-1"

WALL REINFORCEMENT, SEE

AT DUCT ENTRANCES, PROVIDE ADDITIONAL1.

NOTES:

6"

C

6"

4" DEEP SUMP

PRECAST TOP COVER PLAN

PRECAST TOP COVER PLAN

BOTTOM SLAB

SECTION "A"

SECTION "C"

SECTION "E"

SECTION "B"

SECTION "D"

SECTION "F"

SCALE: 3/4"=1'-0" E-508

BLDG 131BLDG 131

E L E

C T

R

IC

A L D

E T

A

IL

S

T H

B

K A

M I

B

K A

M I

W A

Y N

E H

H A

N A

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:31 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP509.dgn

J U

N E

P T

IO

N A

L V

A L

U E s b -B

E

P .d

A1 A4 E-509

E L E

C T

R

IC

A L D

E T

A

IL

S

T H

B

K A

M I

B

K A

M I

1/2"

2"

/4

/4

/2

COVER FOR LOCATION)

OF REMOVABLE CONCRETE

1/8" x 1" (SEE PLAN

SPACER BAR 1/2" x

CONCRETE COVER

FRAME FOR REMOVABLE

L 2 1/2" x 2 1/2" x 1/4"

1/8

/2

1 3/4"

/8

/8

LENGTH

THICKNESS W/ INSERT

TO ANGLE FRAME. VERIFY

x 1 1/2" PLATE WELDED

FILLER PL 5/8" x 1 1/2"

COATS ZRC.

@ COAT WELDS W/ 2

GALVANIZING. CLEAN

WELD INSERT AFTER

STORAGE

INSERT PLUG DURING

FOR THREADING OPENING.

THREADED PLASTIC PLUG

DIA

1"

THIN SLAB INSERT

STAINLESS STEEL

3/4" DIA x 1 5/8" x 1/4" FRAME

L 2 1/2" x 2 1/2"

WHERE OCCUR

TERMINATORS

DUCT ENTRANCE

HANDHOLE WALL

C L

R /2

CLR

1/2"

WALL ELEVATION

SLAB TO TOP SLAB

FROM BOTTOM

EA SIDEOF DUCTS

ADD 1- #5 VERTICAL

LENGTH

ENTIRE WALL

ADD 2- #5 HORIZ.

CORNER

DIAGONAL EA

ADD 1-#4 x 3' LONG

LENGTH

ENTIRE WALL

ADD 1-#5 HORIZ

ELEC

1 3/4" 1 3/4"

3'-3 3/4"

1 3/4"

3'-3 3/4"

2"

/8

/8

/4

H O

L D T

H

IS

D

IM

E N

S

IO

N

2"

"COMM" - TELECOMM

"ELEC" - ELECTRICAL

COVER LOGO:

1 3/4"

CONSTRUCTION

FRAME WELDED

L 2 1/2" x 2 1/2" x 1/4"

GRND SMOOTH

TYP ALL CORNERS

SPACER

CONCRETE FILL

DEVICES

2-LIFTING

COVER

FOR REMOVABLE CONCRETE

SPACER BAR 1/2" x 1/8" x 1"

HOLD THIS DIMENSION

PLAN

SECTION

/2

2 1/2" x 2 1/2" x 1/4" FRAME

LIFTING DEVICE

6"

2"

3/4"

1 1/4" 1 1/4"

3/4"

/4

OR EQUIVALENT

SEALANT CONT

RAM-NEK JOINT

TYPICAL JOINT DETAIL

D1 4'x6' PRECAST CONCRETE HANDHOLE COVER DETAILS

SPACER BAR

PART ELEVATION

PART SECTION

LIFTING DEVICE

WELD STAINLESS STEEL THIN SLAB INSERT TO FRAME.

AND SPACER GARS AFTER FABRICATION, AFTER GALVANIZING,

HOT DIPPED GALVANIZED L FRAME OR FRAME, STEEL RODS, 1.

NOTE:

"A" "A"

"B""B"

4 1/8"

5" 5"

/2

/2 "4 1/8"

R=2 5/

PRECAST CONC WALL

(STAINLESS STEE)

BEARING PLATES

3/4" x 4" x 8"

2 1/8"

EQUIVALENT

SEALANT CONT. OR

RAM-NEK JOINT

3/8" CHAMFER, TYP

3/8" CHAMFER, TYP

TACK WELD

(STAINLESS STEE)

BEARING PLATES

3/4" x 4" x 8"

PULLING IRON

7/8" U-BOLT

EQUIVALENT

SEALANT CONT. OR

RAM-NEK JOINT

PULLING IRON

7/8" U-BOLT

E8

AT DUCT ENTRANCES

HANDHOLE REINFORCEMENT DETAIL

NOT TO SCALE

TYPICAL PULLING IRON DETAILS

SECTION "B" SECTION "A"

NOT TO SCALE

NOT TO SCALE

NOT TO SCALE

W A

Y N

E H

H A

N A

O

LOADS

OTHER

LOADS

OTHER

600A

FEEDER #3 (PREFERRED)

FEEDER #7

LOADS

OTHER

LOADS

OTHER

NC

LOADS

OTHER

NC

NO NC

NC

FIRE STATION

225 KVA

TP-140

3P800A

3P350A 3P350A 3P225A

B132B131B130

7.2KV

SUBSTATION

B133

750KVA

TP-133

2 1

#1/0 G, 4"C

4-500kcmil, KIOSK

2P30A

480Y/277V, 3Ø, 4W

SWBD A

500KVA

TP-131

XFMR

EXST

EMH-UE-A-3

EXST ELEC MANHOLE

HH-0123A

EXST ELEC HANDHOLE

SW7-1B

MTD SW

PAD

SW7-1A

MTD SW

EXST PAD

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:32 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP601.dgn

J U

N E

P T

IO

N A

L V

A L

U E

EP601

/51 WHM 5IN

/51 WHM 5IN

NOT TO SCALE

IN

G L E L

IN

E D

IA

G R

A M

ELECTRICAL SITE DEMOLITION SINGLE LINE DIAGRAM BLDG 131

E L E

C T

R

IC

A L S

IT

E D

E M

O L

IT

IO

N

KEY NOTES:

SPLICE TO NEW FEEDER FROM CUP. SEE SHT. EP651.

PULL INTO HANDHOLE. CUT EXCESS SLACK &

SITE PLAN). DISCONNECT FEEDER FROM SWBD AND

INTERCEPT KIOSK FEEDER WITH HANDHOLE (SEE

SEE EP603 FOR NEW FEEDER TO RECONNECT XFMR.

DISCONNECT & REMOVE EXISTING TP-133 FEEDER.

s b -B

E

P

T H

B K

B

K A

M I

B

K A

M I

W A

Y N

E H

H A

N A

O

(1ST FLR)

DISTRIBUTION PANEL 4B

1-#2480V-120/240V, 3Ø, 4W (1ST FLR)

150KVA TRANSFORMER

1-#2

(1ST FLR)

PANEL "2BJ"

1#4 GND

3"C, 4#4/0, 1#2 GND

4"C, 4#500 KCMIL,

WIREWAY

1#4 GND

3"C, 4#4/0, (2ND FLR)

(SECTIONS 1 & 2)

PANEL "2BE"

(3RD FLR)

PNL "2BG" (SECTIONS 1 & 2)

1-#2

4#4, 1 1/4"C

3#1, 1#8 GRD, 1 1/2"C

2"C, 3#1/0, 1#6 GND

3"C, 3#4/0, !#6 GND

(1ST FLR)

480V-20/208V, 3Ø, 4W

75KVA TRANSFORMER

3"C, 4#4/0, 1#4 GND

(1ST FLR)

PANEL "2BH"

2"C, 4#1/0, 1#6 GND

(1ST FLR)

PANEL "2BF"

10,000 AIC

PANEL "2BD"

10,000 AIC

PANEL "2BC"

10,000 AIC

PANEL "4BB"

10,000 AIC

PANEL "2BB"

10,000 AIC

PANEL "2BA"

277V

1P-20A

2 1/2"C

4-250MCM,

277V

1P-20A

4#4 1 1/4"C

14,000 AIC

PANEL "4BA" 1-#2

480V-20/208V, 3Ø, 4W

75KVA TRANSFORMER

480V-20/208V, 3Ø, 4W

75KVA TRANSFORMER

4#4, 1 1/4"C

3#1, 1#8 GRD, 1 1/2"C

FEED THRU LUGS FEED THRU LUGS

BARRACKS "B"

22,000 AIC

400A, 480V/277V, 3Ø, 4WSN

DISTRIBUTION PANEL "4B"

1-#3/0

PANEL

FIRE ALARM

480V-120/240V, 1Ø, 3W

1.5KVA TRANSFORMER

2P-30A

5A CLF

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

1:38:33 PM7/1/2019

c:\pw-work\poh-1\j3ec9evr\d0244374\18sb04-131_EP602.dgn

J U

N E

P T

IO

N A

L V

A L

U E

EP602

3P-125A

TC

TC

3P-125A

3P-125A

PFB

3P-100A

PFB

3P-70A

P -3

A

3P-100A

PFB

(25,000A/C MIN)

3P-125A

(25,000A/C MIN)

3P-225A

P -2

A

P -2

A

3P-150A

3P-225A

P -1

A

P -2

A

NOT TO SCALE

ELECTRICAL DEMOLITION SECONDARY SINGLE LINE DIAGRAM BLDG 131

IN

G L E L

IN

E D

IA

G R

A M

E L E

C T

R

IC

A L D

E M

O L

IT

IO

N S

E C

O N

D A

R Y

M

NOTES:

RELOCATE METER. SEE EP604.

FIRE PROTECTION DWGS.

DISCONNECT FIRE ALARM PANEL. SEE

TURN OVER TO CONTRACTING OFFICER

REMOVE EXST CTS AND METERS AND

s b -B

E

P .d g n

T H

B K

B

K A

M I

B

K A

M I

W A

Y N

E H

H A

N A

O

OTHER

LOADS

OTHER

LOADS

600A

OTHER

LOADS

OTHER

LOADS

NC

OTHER

LOADS

NC

NO NC

NC

TP-140

225 KVA

FIRE STATION

TP-131

500KVA

3P800A

3P350A 3P350A 3P225A

B132B130

SWBD

480Y/277V, 3Ø, 4W

SUBSTATION

7.2KV

1 2

EXISTING PAD

MTD SWITCH

"SW7-1B"

EXISTING PAD

MTD SWITCH

"SW7-1A"

EXISTING ELEC

MANHOLE "EMH-UE-A-3"

100A

EXST ELEC

HANDHOLE

"UE-A-19"

EXST B133 PAD

MTD XFMR

"TP-133"

FUTURE B130

PAD MTD XFMR

(PACKAGE 2)

PAD MTD SW

"SW-A"

14.4KV, 3Ø

ELEC

MANHOLE A

"EMH-A"

ELEC

MANHOLE C

"EMH-C"

ELEC

MANHOLE D

"EMH-D"

ELEC

MANHOLE B

"EMH-B"

FUTURE B132

PAD MTD XFMR

(PACKAGE 2)

BLDG 131 & CUP

XFMR A

750KVA, 7.2/12.47KV-

480Y/277V, 3Ø, 4W

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

5:05:04 PM7/2/2019

pw:\\COE-POHPWP08FTS.poh.ds.usace.army.mil:coe-pohpwp08fts.poh.ds.usace.army.mil\Documents\Military\02 SB\Projects\2018\18sb04 - FY19 OMA REPAIR QUAD A, BLDG 131 AND CENTRAL UTILITY PLANT, SB\02 Engineering Design\02 Plans and Specs\CAD_BIM\CADFiles\K-Ele

J U

N E

P T

IO

N A

L V

A L

U E

EP603A1

NOT TO SCALE

S

IN

G L E L

IN

E D

IA

G R

A M

ELECTRICAL PRIMARY SINGLE LINE DIAGRAM

E L E

C T

R

IC

A L P

R

IM

A

Y

BLDG 131

s b -B

E

P .d g n

T H

B K

B

K A

M I

B

K A

M I

W A

Y N

E H

H A

N A

O K

A

3-#4/0, #1/0 BC GND IN EXST 4"C

KEY NOTES:

5"C, 3-#4/0, #1/0 BC GND

SLACK FOR FUTURE SPLICE.

HANDHOLE INTERIOR TO PROVIDE

CABLES TWICE AROUND MANHOLE/

SPLICE CABLES IN MANHOLE, LOOP

DUCTS, REPAIR TO MATCH EXISTING

BREAK HANDHOLE WALLS TO INSTALL

SEQUENCE OF WORK

THE NUMBER AND DURATION OF OUTAGES AT B133:

A.

B.

C.

D.

E.

F.

G.

THE FOLLOWING SEQUENCE OF WORK IS SUGGESTED TO MINIMIZE

TP-133 FEEDER.

OPEN SW 2 AT EXST PAD MTD SW SW7-1B TO DE-ENERGIZE OLD

CLOSE TP-133 SWITCH 1 TO ENERGIZE TP-133 FROM PAD MTD SW A.

AND 7 TOGETHER.

TRANSFORMER AND PREVENT TYING EXISTING FEEDERS 3

SWITCH WITH OLD FEEDER (E.G., 2) TO DE-ENERGIZE THE

AS DIRECTED, PROVIDE OUTAGE AT B133. AT TP-133, OPEN

OFFICER. ENSURE NEW FEEDER TO TP-133 IS ENERGIZED.

COORDINATE AN OUTAGE FOR B133 WITH THE CONTRACTING

AND CONNECT.

CABLE TERMINATIONS TO MATCH EXISTING TP-133 CONNECTIONS

ENSURE THE SPARE SWITCH AT TP-133 (E.G., 1) IS OPEN. PROVIDE

AND TEST.

CONDUCTOR FROM PAD MTD SW TO TP-133 VIA NEW AND SPARE DUCTS,

ENSURE PAD MTD SW A SWITCH 2 IS OPEN. EXTEND NEW FEEDER

CONSTRUCT, ENERGIZE, AND TEST PAD MTD SW A.

EXTEND NEW DUCTS FROM MANHOLE A TO EXST HANDHOLE UE-A-19.

CONSTRUCT MANHOLES A AND B, AND INTERCONNECTING DUCTS.

5"C W/ PULLSTRING

/51 WHM 5IN

/51 WHM 5IN

FEEDER #3

FEEDER #7

(PREFERRED)

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

F Y Q

U A

D A R

E P

A

IR

B

L D

G

N O

L U

L U D

IS

T R

IC

T

F T S

H A

F T

E R

H A

W

G

IO

N A

L E

N G

IN

E E

R

IN

G C

E N

T E

R

H O

N O

L U

L U E

N G

IN

E E

R D

IS

T R

IC

T

H O

N O

L U

L U

H

O F

IE

L D B

A R

R A

C K

S

O A

H U

H A

W

D C

O N

S T

R U

C T C

E N

T R

A L U

T

IL

IT

Y P

L A

E N

A M

E

5:07:17 PM7/2/2019

pw:\\COE-POHPWP08FTS.poh.ds.usace.army.mil:coe-pohpwp08fts.poh.ds.usace.army.mil\Documents\Military\02 SB\Projects\2018\18sb04 - FY19 OMA REPAIR QUAD A, BLDG 131 AND CENTRAL UTILITY PLANT, SB\02 Engineering Design\02 Plans and Specs\CAD_BIM\CADFiles\K-Ele

J U

N E

P T

IO

N A

L V

A L

U E

EP606NOT TO SCALE

ELECTRICAL MANHOLE SCHEMATIC DIAGRAM

L E

C T

R

IC

A L M

A N

H O

L E S

C H

E M

A T

IC

D

IA

G R

M

BLDG 131

s b -B

E

P .d g n

T H

B K

B

K A

M I

B

K A

M I

W A

Y N

E H

H A

N A

O K

A

NOTES:

EXST CKT 18 CONDUCTORS

EXST ST LTG CONDUCTORS

EXST CKT 7, 3-#4/0, 15KV CABLES

EXST CKT 3, 3-#4/0, 15KV CABLES

NEW PAD MTD SW "A"

T-SPLICE TO EXTEND CKT 7 TO

BLOW EXISTING SPICE, PROVIDE

SHEET EP603 FOR CONDUCTOR SIZES

SW "A". SEE PRIMARY SINGLE LINE

MTD SW "SW7-1B" AND NEW PAD MTD

EXTEND NEW CABLES TO EXST PAD

EXCESS. PROVIDE T-SPLICE TO

SLACK CABLES IN MANHOLE AND CUT

AND PULL BACK INTO MANHOLE. COIL

CABLES FROM EXST SW "SW7-1B"

A T-SPLICE. DISCONNECT EXST

ENOUGH SLACK CABLES TO PROVIDE

IT APPEARS THAT THERE IS NOT

REPAIR TO MATCH EXST

BREAK MH WALLS TO INSTALL DUCTS,

5" C STUB OUTS TO PACKAGE 2 XFMR

CONDUIT AND CABLES (TYP)

LINE DIAGRAM, SHEET EP603, FOR

SEE ELECTRICAL PRIMARY SINGLE

PLAN

NORTH

PAD MTD SW "SW7-1B"

EXST 2-4C" TO EXST

2-5"C TO PAD MTD SW "SW-A"

SW "SW7-1B"

EXST PAD MTD

"UE-A-3"

MANHOLE

EXST

"UE-A-19"

HANDHOLE

EXST

"EMH-B"

MANHOLE

ELEC

"EMH-A"

MANHOLE

ELEC

"EMH-C"

MANHOLE

ELEC

"EMH-D"

MANHOLE

ELEC

"SW-A"

PAD MTD SW

"TP-131"

EXST TO

EXST B133 XFMR

B131 CUP XFMR

INDUSTRIAL BOLTED

NO. POLE AMP AMP POLE NO.

** ** 1 UNIT U102 2 90 6.3 6.3 90 2 UNIT U104 2 ** **

** ** 3 ‐ ‐‐ 6.3 6.3 ‐‐ ‐ 4 ** **

** ** 5 UNIT U202 2 90 6.3 6.3 90 2 UNIT U204 6 ** **

** ** 7 ‐ ‐‐ 6.3 6.3 ‐‐ ‐ 8 ** **

** ** 9 UNIT U302 2 90 6.3 6.3 90 2 UNIT U304 10 ** **

** ** 11 ‐ ‐‐ 6.3 6.3 ‐‐ ‐ 12 ** **

** ** 13 UNIT U106 2 90 6.3 6.3 90 2 UNIT U108 14 ** **

** ** 15 ‐ ‐‐ 6.3 6.3 ‐‐ ‐ 16 ** **

** ** 17 UNIT U206 2 90 6.3 6.3 90 2 UNIT U208 18 ** **

** ** 19 ‐ ‐‐ 6.3 6.3 ‐‐ ‐ 20 ** **

** ** 21 UNIT U306 2 90 6.3 6.3 90 2 UNIT U308 22 ** **

** ** 23 ‐ ‐‐ 6.3 6.3 ‐‐ ‐ 24 ** **

** ** 25 UNIT U110 2 90 6.3 6.3 90 2 S 26

** ** 27 ‐ ‐‐ 6.3 6.3 ‐‐ ‐ 28

** ** 29 UNIT U210 2 90 6.3 1.0 20 1 S 30

** ** 31 ‐ ‐‐ 6.3 1.0 20 1 S 32

** ** 33 UNIT U310 2 90 6.3 1.0 20 1 S 34

** ** 35 ‐ ‐‐ 6.3 1.0 20 1 S 36

37 PFB 3 100 100 3 PFB 38

39 ‐‐ ‐ 40…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.