Attch 38 LOCRF DRAWINGS AMENDMENT 09FEB2022.pdf
PDF 4 MB Posted
- Attached to
- F-22 Low Observable Component Repair Facility (LOCRF) Federal contract opportunity
- Solicitation number
- W9123621R2023
About this file
This solicitation is for the construction of a Low Observable Component Repair Facility to support F-22A aircraft maintenance at Langley Air Force Base in Virginia. The project includes construction of a 6,735 square meter facility with three low observable critical repair hangar bays, one wash rack hangar bay, shops, support spaces, administration areas, restrooms and mechanical/electrical rooms. Each hangar bay will be equipped with air filtration systems. Additional requirements include site utilities, pavements, security features and detection protection. The facility must withstand seismic and wind loads according to applicable codes and guides. Sustainable practices will be integrated under UFC 1-200-02. The facility will provide corrosion control maintenance space and a wash rack bay. Fire protection, male/female restrooms with showers and lockers, and electrical/mechanical support rooms will also be included. Site utilities must support F-22A power-up, data and diagnostic equipment needs. The construction contract duration is expected to be 730 calendar days.
View the file
Other files for this federal contract opportunity
Show all 50
F-22 Low Observable Component Repair Facility (LOCRF) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
16" DEEP MIN. CONC. TIE BEAM
W/ (2) #5 CONT. TOP, MIDDLE,
BOTTOM & #3 TIES AT 1'-4" O.C.
STEP B/TIE BEAM W/ ROOF
SLOPE. SEE E7/S-514
METAL DECK SEE PLAN
T/WALL EL.
SEE PLAN
CMU WALL, SEE
FDN. PLAN
SINGLE PL. CONN.
SEE F4/S-512
EMBED PL, SEE C4/S-512 S-321
A1
STEEL JOIST
SEE PLAN
METAL DECK SEE
PLAN
3/16 2 1/2
JOIST BRG.
SEE PLAN
CMU WALL, SEE FDN.
PLAN
8" DEEP BOND BEAM
W/ (2) #5 CONT.
3/8" X 4" X 8" PL. W/ (2)
3/8" ⌀ X 6" HSA'S
WALL CLADDING,
SEE ARCH.
STD. HOOK
GUTTER, SEE ARCH.
L5X3X1/4 (LLH) CONT.
PARTIAL HT. CMU COURSE
CMU LINTEL, SEE SCHEDULE, S-515
WINDOW, SEE ARCH.
LOOSE LINTEL*, SEE
SCHEDULE,
L4X4X1/4 CONT. DECK EDGE ANGLE
3/16 3-12
3/16 3-12
5/8" ⌀ DIAA AT 2'-0" OC IN VERT-SLOTTED
HOLE. FINGER TIGHTEN & MAR THREADS.
*DO NOT INSTALL WINDOWS UNTIL LINTELS ARE LOADED
WITH FULL WEIGHT OF WALL CLADDING
JOIST TCX 2" BEYOND
FACE OF WALL
3"
/E4 S-515
T O
S
8"
2"
L5X5X1/4 CONT. W/ PRE-
DRILLED HOLES
STEEL JOIST
SEE PLAN
METAL DECK, SEE
PLAN
CMU WALL, SEE
FDN. PLAN
T/WALL EL.
SEE PLAN
GRID
8" MIN. DEEP CIP CONC.
SLOPED RAKE BEAM OR
CMU SLOPED RAKE BEAM,
SEE E7/S-514
CLADDING, SEE ARCH.
DECK PERIMETER ATTACHMENT,
SEE S-002
JOIST BRIDGING
PER SJI
BRIDGING ANCHORAGE TO
WALL, SEE DET. A3/S-514
COPING, SEE ARCH.
3/4" ⌀ DISA AT MAX. 2'-0" O.C.
8" WALL TH: 4" EMBED
12" WALL TH: 6" EMBED
16" DEEP CMU BOND
BEAM W/ 2-#5 CONT. EA.
COURSE. STEP W/ ROOF
SLOPE PER DET. B3/S-514
L5X5X5/16 CONT
3"
2-#5 CONT.
STEEL JOIST
SEE PLAN
METAL DECK SEE PLAN
3/16 2 1/2
TYP
JOIST BRG.
SEE PLAN
CMU WALL, SEE
FDN. PLAN
CUT BLOCK AS REQ'D FOR
JOIST BRG. ELEV.
1/2" X 8" X 8" PL. W/ (2) 1/2"
⌀ X 8" HSA'S AT 4" GAGE
16" DEEP BOND
BEAM W/ 2-#5
CONT. EA. COURSE
SOLID GROUTED BOND BEAM
W/ 2 - #5 CONT.
METAL DECK SEE PLAN
T/STEEL
SEE PLAN
GRID
8" CMU WALL,
SEE FDN. PLAN
3/8" X 6" WIDE X 1'-0" LONG W/
3 - 1/2" X 6" HSA'S CENTERED
ON PL. & 2" FROM ENDS
WF BEAM, SEE PLAN
CONT. EDGE ANGLE, SEE
3/8" STIFF. PL. EA. SIDE
1/4 4
1'-4" LONG BEAM POCKET. BACKFILL
W/ GROUT AFTER BEAM INSTALL.
6"
CONT. RAKE BEAM & BOND
BEAM, SEE E7/S-514
/E7 S-321
CMU WALL REINF CONT TO TOP
OF WALL BEYOND, SEE PLAN
24" DEEP SOLID GROUTED BOND BEAM
W/ 2 - #5 CONT. TOP, BOTT, & MID.
#3 TIES @ 16" OC
METAL DECK, SEE PLAN
CMU WALL, SEE
FDN. PLAN
3/8" X 6" WIDE X 8" LONG W/ 2 - 1/2"
X 6" HCA'S CENTERED ON PL. & 2"
FROM EDGES
BEAM, SEE PLAN
3/8" STIFF. PL. EA. SIDE
1/4 4
6"
#4 CORNER BAR
1'-4" LONG BEAM POCKET
2 - #5 W/ 180° HOOK AROUND
CORNER STUD (ONE IN EA. DIR),
SEE S-601 FOR HOOK DIM'S
CMU WALL REINF, SEE PLAN
1/2" GAP
CMU WALL, SEE
FDN. PLAN
MIN.8" DEEP BOND BEAM
W/ 2-#5 CONT.
METAL DECK SEE PLAN
PARTIAL HT. CMU COURSE
1/2" X 6" X 6" PL. AT 2'-0"
OC W/ (2) 1/2" ⌀ X 5"
HSA'S AT 4" GAGE
5/8" ⌀ PUDDLE WELDS AT 12" OC,
METAL DECK TO PL.
CONT. 3/8" X 4" PL.
1/4
SOLID GROUTED BOND
BEAM W/ 2 - #5 CONT.
METAL DECK SEE PLAN
12" CMU WALL,
SEE FDN. PLAN
3/8" X 6" WIDE X 8" LONG W/
2 - 1/2" X 6" HSA'S CENTERED
ON PL. & 2" FROM EDGES
CONT. EDGE ANGLE, SEE
1'-4" LONG BEAM POCKET.
BACKFILL W/ GROUT AFTER
BEAM INSTALL.
/E7 S-321
CMU WALL REINF CONT
BEYOND, SEE PLAN
CMU WALL, SEE
FDN. PLAN
BRICK VENEER,
SEE ARCH
METAL DECK
SEE PLAN
PARTIAL HT. CMU COURSE
L8X4X1/2 CONT. W/ 1/2"
⌀ X 5" HSA'S AT 2'-0" OC
5/8" ⌀ PUDDLE WELDS AT 12" OC,
METAL DECK TO PL.
MIN.8" DEEP BOND
BEAM W/ 2-#5 CONT.
L5X3X1/4 (LLH)
CONT.
3/16 3-12
3/16 3-12
2X BLOCKING,
SEE ARCH
FV
3 1/2"
FV
1 1/2"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
R H
A M
M E
T T
N A
O F
IL
E
N O
A
W -2
-R
-2
BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_S_R19.rvt
2/9/2022 10:48:47 AM
S-321
R O
O F
F R
A M
IN
G
S E
C T
IO
N
S
I
F Y
F
-2
F O
R M
A L
T R
A
IN
IN
G
U N
IT
F T
U
P M
U L L
L P
O U
R C
IA
U
M S
T
IE
L S
T R
A
-2
-2
L O
W O
B S
E R
V A
B L
E C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
L
O C
R F
SCALE: = 1'-0"3/4"
0 1 2 31
SCALE: 3/4" = 1'-0"
C7
SECTION @ BEAM AT CIP TIE BEAM
SCALE: 1" = 1'-0"
E1
SECTION @ JOIST BRG. AT CMU WALL
SCALE: 3/4" = 1'-0"
E7
SECTION @ ROOF DECK AT EXT CMU PARAPET
SCALE: 3/4" = 1'-0"
E4
SECTION @ JOIST BRG. AT INT CMU WALL
SCALE: 3/4" = 1'-0"
C1
SECTION @ WF BEAM POCKET AT EXT'R WALL
SCALE: 3/4" = 1'-0"
C4
SECTION @ WF BEAM BRG. AT CMU CORNER
SCALE: 3/4" = 1'-0"
A1
SECTION @ INT'R CMU WALL
SCALE: = 1'-0"
0 1 21
1"
SCALE: 1" = 1'-0"
A4
SECTION @ JOIST BEAM POCKET
SCALE: 3/4" = 1'-0"
A7
SECTION @ SLOPED DECK EDGE
A
M E
N D
M E
N T
-0
-2
-0
-2
CAST-IN-PLACE CONC. (OR CMU)
TIE BEAM OR BOND BEAM
PLACE METAL LATH OR WIRE SCREEN OVER CELLS
NOT TO BE FILLED (FELT AND SHEET METAL ARE
NOT PERMITTED)
VERTICAL REINFORCING W/ ACI STANDARD HOOK AT
TOP OF WALL. PROVIDE MATCHING DOWELS IN
FOUNDATION AND LAP. SEE PLAN FOR SIZE AND
SPACING.
JOINT REINF AT 16" OC
CAULK EA. SIDE OF JOINTPROVIDE CENTERED OR
EACH FACE VERT. REINF
ON EA. SIDE OF MCJ TO
MATCH WALL REINF., TYP.
PREMOLDED RUBBER INSERT
NOTE: DISCONTINUE HORIZ. JOINT REINF. AT JOINT
HORIZ. BEAM REINF.
CORNER BARS TO MATCH
SIZE & QUANTITY OF BOND
BEAM REINF.
GROUT
3-VERT BARS AT
CORNER, TYP
TYP.
2' - 0" LAP MIN.
METAL LATHE
CMU WALL
HORIZ. BOND
BEAM REINF.,
SEE DETAILS
DOUBLE CORNER BAR TO
MATCH HORIZ. BOND BEAM
REINF. GROUT FILL
MCJ CONT. BOND BEAM W/ 1-#
5 EA. FACE TYP., UNO
REINF. EA. SIDE OF MCJ TO
MATCH WALL REINF., TYP, UNO
LINTEL REINF. SEE
SCHEDULE, S-515
TYPICAL
DOOR
OPENING
TYPICAL
OPENING
VERTICAL REINF, SEE PLAN
HORIZONTAL BOND BEAM,
SEE SECTIONS
CAST-IN DOWEL TO
MATCH VERT REINF
L A
P S
E E
S -6
1-#5 EACH FACE
2' - 10"2' - 10"
PROVIDE CLEANOUT AND
INSPECTION HOLES AT BOTT.
OF CMU WALL AT REINF.
NOTES:
1. SEE PLAN FOR VERTICAL REINFORCING. SEE GENERAL NOTES FOR ADDITIONAL INFORMATION.
TOP OF WALL
JAMB REINF. SEE
D1 & D5 ON S-516
LINTEL REINF. SEE
SCHEDULE, S-515
L A
P S
E E
S -6
B/WALL
SEE PLAN
B/WALL
SEE PLAN
STD. HOOK, TYP. AT
TOP OF WALLS
BOTH BARS CONT. THRU MCJ
ONE BAR CONT. THRU MCJ, TYP. AT
BOND BEAMS, UNO
CMU WALL,
TYP.
MTL. DECK
TYP.
JOIST BRIDGING PER
SJI
JOIST
L3x3x1/4 x 1'-0" LG W/ (2) 5/8"Ø
DISA'S (4" EMBED) TYP IN GROUTED
CELLS OR CIP CONCRETE
VERT. BAR POSITIONERS; LOCATE AT TOP
OF FIRST COURSE, AND ONE COURSE
BELOW TOP OF WALL.
VERT. REINF. SEE
PLAN
GROUT
CENTERED REINF. EACH FACE REINF.
C L R
E Q
E Q
STL DECK SEE PLAN
NON-LOAD BEARING INT'R
CMU WALL, SEE PLAN
/2
L3X3X12GA x CONT EA. SIDE
OF WALL W/ #12 TEK SCREWS
INTO STL DECK @ 12" O.C.
INSTALL TIGHT TO WALL BUT
DO NOT ATTACH.
FILL GAP W/ MINERAL WOOL
INSULATION WHERE REQD FOR FIRE
RATING. COORD W/ ARCH.
INTERIOR NON-LOAD BEARING
CMU WALL w/ #5 @ 40" OC MAX.
DIAA, 4" MIN. EMBED.
L A
P P
E R
S C
H
1' - 6"
CONC SLAB
SEE PLAN
(2) #4 CONT & #4 @
12" OC TRANSV.
C L R
REINF. SEE SECTION
CMU WALL
M
IN
. T/RAKE BEAM VARIES
SEE PLAN
S T
E P
1 ' - 8 "
B O
N D
B E
A M
1'
C M
U
T/METAL DECK
S-514
B3 TYP AT BOND BEAM STEP
REINF. SEE SECTION
SLOPED MASONRY RAKE BEAM OPTION
CMU TO MATCH
ROOF SLOPE
FULLY GROUTED CMU
BOND BEAM, TYP
T/RAKE BEAM VARIES
SEE PLAN
SLOPED CONCRETE
RAKE BEAM AT PARAPET,
SEE PARTIAL DETAIL FOR
MASONRY OPTION
CUT CMU BELOW
TOP BOND BEAM
8" 8"
CL
CL
8" 8"
8" CMU WALL AT COL.
CENTERLINE, SEE PLAN
SOLID GROUTED JAMB W/
1-#5 VERT.HSS COL, SEE PLAN
4" CMU WRAP, ALTERNATE
COURSES IN RUNNING
BOND
SEE ARCH.
8 9/16"
3/8" X 8" X 8" HOT DIP
GALV. BENT PL. CONT.
5/8" ⌀ DIAA AT 24" OC INTO
SOLID GROUTED BOND BEAM
BRICK VENEER*, SEE ARCH.
8" OR 12" CMU WALL, SEE PLAN
6"
EMBED.
5 5/8"
*MAXIMUM 16 FT HEIGHT OF BRICK SUPPORTED BY THIS CONFIGURATION
STL PURLIN BY PEMB MFR.
NON-LOAD BEARING
CMU WALL, SEE PLAN
L5X3X1/4 (LLV) x CONT EA. SIDE
OF WALL. INSTALL TIGHT TO
WALL BUT DO NOT ATTACH.
FILL GAP W/ MINERAL WOOL
INSULATION WHERE REQD FOR FIRE
RATING. COORD W/ ARCH.
1/
2"
3/16
TYP
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
R H
A M
M E
T T
N A
O F
IL
E
N O
A
W -2
-R
-2
BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_S_R19.rvt
2/9/2022 10:44:48 AM
S-514
M A
S O
N R
Y D
E T
A
IL
S
I
F Y
F
-2
F O
R M
A L
T R
A
IN
IN
G
U N
IT
F T
U
P M
U L L
L P
O U
R C
IA
U
M S
T
IE
L S
T R
A
-2
-2
L O
W O
B S
E R
V A
B L
E C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
L
O C
R F
SCALE: N.T.S.
E1
TYP MASONRY WALL CONSTRUCTION
SCALE: N.T.S.
B1
CMU CONTROL JOINT DETAIL
SCALE: N.T.S.
D3
CMU BOND BEAM CORNER DETAIL
SCALE: N.T.S.
B3
TYP STEPPED BOND BM DETAIL
SCALE: N.T.S.
E3
CMU WALL REINF. ELEVATION
SCALE: N.T.S.
A3
JOIST BRIDGING DETAIL
SCALE: N.T.S.
D1
CMU - VERT CELL REINF DETAIL SCALE: N.T.S.
D8
INT'R NON-LOAD BRG WALL SECTION
SCALE: N.T.S.
A6
TYP. INT'R NON-LOAD-BRG. CMU WALL
FDN. DETAIL
SCALE: N.T.S.
E7
ROOF CONCRETE TIE BEAM STEP DETAIL
SCALE: N.T.S.
D6
HSS COL WRAP DETAIL
SCALE: N.T.S.
A8
BRICK SHELF ANGLE DETAIL
SCALE: N.T.S.
B8
EXT'R NON-LOAD BRG WALL SECTION
A
M E
N D
M E
N T
-3
-2
-3
-2
A
M E
N D
M E
N T
-0
-2
-0
-2
1 1
EQUIPMENT SHEET NOTES
1. THE GOVERNMENT FURNISHED EQUIPMENT GFE LIST IDENTIFIES ITEMS
PROVIDE BY THE GOVERNMENT.
2. GF/GI IDENTIFIES GOVERNMENT FURNISHED/GOVERNMENT INSTALLED
EQUIPMENT. CONTRACTOR TO COORDINATE WITH THE GOVERNMENT TO
MAKE SURE THAT THIS WORK IS PERFORMED WITHOUT INTERFERENCE OF
OTHER WORK. CONTRACTOR TO PROVIDE FOR ANY AND ALL ELECTRICAL
OR MECHANICAL CONNECTIONS NECESSARY FOR OPERATION OF THE
EQUIPMENT AS SCHEDULED. SEE ENGINEERING DRAWINGS FOR FURTHER
INFORMATION.
3. GF/CI IDENTIFIES GOVERNMENT FURNISHED/CONTRACTOR INSTALLED
EQUIPMENT. CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES TO
MAKE SURE THE INSTALLED EQUIPMENT IS FULLY CONNECTED AND
OPERATIONAL. AFTER INSTALLATION EQUIPMENT SHALL BE TESTED TO
MAKE SURE ALL THE NECESSARY CONNECTIONS ARE MADE AND THE
EQUIPMENT IS FULLY OPERATIONAL. CONTRACTOR TO PROVIDE ALL
NECESSARY ELECTRICAL, PLUMBING AND MECHANICAL CONNECTIONS TO
GF EQUIPMENT INCLUSIVE OF LABOR AND MATERIAL NECESSARY FOR A
FULL FUNCTIONAL CONNECTION.
4. GF/CI EQUIPMENT NECESSARY CONNECTIONS SHALL BE VERIFIED BY THE
CONTRACTOR BEFORE ANY WORK AND INSTALLATION TAKES PLACE.
GENERAL SHEET NOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
R H
A M
M E
T T
N A
O F
IL
E
N O
A
W -2
-R
-2
BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_A_R19.rvt
2/8/2022 7:28:26 PM
A-011
E Q
U
IP
M E
N T
S C
H E
D U
L E
M
E T
A L
S T
E C
H
S H
O P
S
F Y
F
-2 F
O R
M A
L T
R A
IN
IN
G U
N
IT
F
T U
M
F
E S
T G
E R
R T
O M
E I
S G
R O
E T
H E
-2
-2
L O
W O
B S
E R
V A
B L
E C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
L
O C
R F
METALS SHOP EQUIPMENT SCHEDULE
EQUIPMENT NAME EQUIPMENT SIZE FOOTPRINT CLEARANCE REQUIRED POWER REQUIREMENT AMPS HVAC REQUIREMENTS PROCUREMENT & INSTALLATION NOTES
MANUAL HARDINGE METAL LATHE 6'x3'x6' 12'x9' 3 PHASE / 460V 30 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
LARGE CLAUSING MILL 6'x6'x8' 12'x12' 1 PHASE / 460V / AIR SUPPLY 13 HOSE AND REEL (100 PSI) GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
MILLER DYNASTY WELDER #1 2'x4'x6' 13'x8' TABLE/FUME EXTRACTOR INCLUDED 460V / 3 PHASE 88 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A - TABLE/FUME
EXTRACTOR IS GF/CI PHASE B
MILLERMATIC 221 MIG WELDER 2'x4'x6' 5'x7' FUME EXTRACTOR INCLUDED 1 PHASE / 110V / 30A 20 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C (INCLUDING FUME
EXTRACTOR)
ASSORTED CTK'S / CONSUMABLES / LOCKERS / BOXES N/A 30'x50' APPROXIMATE N/A N/A GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
HASS TL2 CNC LATHE 6'x9'x6' 15'x12' 3 PHASE / 220V / AIR SUPPLY 25 HOSE AND REEL (100 PSI) GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
HAAS VF2 CNC MILL 9'x9'x10' 15'x15' 3 PHASE / 240V / AIR SUPPLY 70 HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
HAAS VF4 CNC MILL CUTTER 14'x9'x10' 20'x15' 3 PHASE / 360V-480V / AIR SUPPLY 35 HOSE AND REEL (100 PSI) GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
OMAX WATERJET CUTTER 24'x12'x10' 30'x20' W/FORKLIFT ACCESS 3 PHASE / 480V / WATER DRAINAGE / AIR 6.5 HOSE AND REEL (100 PSI). WATER FAUCET BEHIND MACHINE GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
SMALL CLAUSING MILL 5'x6'x8' 12'x12' 240/480 SINGLE PHASE / AIR SUPPLY 11.7 HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
SMALL CLAUSING LATHE 6'x4'x6' 12'x10' 3 PHASE / 230V 32 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
LARGE CLAUSING LATHE 9'x4'x6' 15'x10' 3 PHASE / 460V 30 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
LARGE VERTICAL BAND SAW 6'x4'x7' 12'x10' 3 PHASE / 460V 5.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
SMALL HORIZONTAL METAL SAW 6'x3'x3' 12'x15' 3 PHASE / 460V 5.4 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
LARGE POWER PRESS 6'x3'x8' 12'x9' 3 PHASE / 460V 15.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
LARGE ARBOR PRESS 1'x2'x6' 4'x4' NONE N/A GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C
DEBURR SHAKER MACHINE 3'x2'x4' 7'x4' 3 PHASE / 230V 8.4 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
STANDUP DRILL PRESS 2'x3'x7' 8'x4' 1 PHASE / 230V 11.5 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
HEAT TREATING OVEN 3'x5'x8' 9'x12' 3 PHASE / 230V 100 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
BELT SANDER / BURR KING 3'x2'x5' 9'x8' 1 PHASE / 110V / 30A 13.4 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C
LARGE GRINDER / WIRE WHEEL 3'x2'x5' 9'x8' 3 PHASE / 220V 3.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
LARGE POWER SHEER 14'x7'x8' 20'x25' 3 PHASE 460V 3.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
LARGE HAND BREAK 10'x2'x4' 16'x12' NONE N/A GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
SMALL FOOT SHEAR 5'x6'x4' 11'x12' NONE N/A GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
S/M TABLE WITH BREAK, ROLLER 6'x12'x5' 12'x18' 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
MILLER DYNASTY WELDER #2 15'x8' TABLE / FUMER INC 10'x8' 1 OR 3 PHASE / 110V 88 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C
LARGE ACCORN WELD TABLE 5'x8'x4' 6'x10' 110V / AIR / REELS N/A GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
METAL IRON WORKER 5'x3'x6' 11'x9' 3 PHASE 460V 6.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
BALDOR GRINDER 3'x2'x5' 8'x4' 230V / 3 PHASE 5.9 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
BALDOR BUFFING WHEEL 8'x9' 8'x9' 2 PHASE / 230V 4.8 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
THOMAS CUTTING SAW 2'x2'x5' 7'x7' 230V SINGLE PHASE 11 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
TURRET SHEET METAL PUNCH 2'x3'x6' 8'x9' 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
SNAP-ON SAND BLASTER 4'x3'x6' 10'x9' 110V / AIR 2.2 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
CHOP SAW LARGE YELLOW 5'x4'x5' 11'x10' 230V / SINGLE PHASE 19 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
TABLE/SENSITIVE DRILL PRESS / HARDNESS TESTER 8'x7' 110V 110V 1.2 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
MILLER XMT 450 WELDER 3'x3'x5' 9'x9' 3 PHASE / 460V 67 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
HYPERTHERM PLASMA CUTTER 2'x2'x4' 3'x3' 1 PHASE / 230V 65 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
OXY-ACEYTYLENE RIG 3'x2'x5' 4'x4' 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C
MILLER MINI MIG WELDER 2'x3'x5' 3'x4' 110V / 220V PLUGS 30 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C
MACHINE ACCY TOOL BOXES 3'x5' NONE 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
SHEET METAL RACK 12'x21' NONE 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
SOUND STOCK METAL RACK 16'x5' NONE NONE N/A GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
LONG METAL RACK 5'x20' NONE 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
MACHINE SHOP TABLE 5'x8'x4' NONE NONE N/A GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B
WELD SHOP TIG TABLE 12'x6' NONE 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
MILLER 252 MIG WELDER 4'x3'x6' 11'x10' 230V SINGLE PHASE 42 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
KALAMAZOO BELT SANDER 4'x3'x6' 8'x9' 230V SINGLE PHASE 19 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A
LOW OBSERVABLE EQUIPMENT SCHEDULE
ROOM NO. ROOM NAME EQUIPMENT NAME MANUFACTURER / MODEL NO. EQUIPMENT SIZE POWER REQUIREMENTS HVAC REQUIREMENT PLUMBING REQUIREMENT COMMENTS PROCUREMENT & INSTALLATION NOTES
143 DAMAGE REMOVAL / PREP AREA SANDING BOOTH DUSTRON SERIES FILTER 1/DB-24-36-2X15 7'-6" H x 8' L x 24' W 3 PHASE / 460/480V STANDARD (FLA OF 18) 208/230V (FLA GOES TO 36) ALSO
AVAILABLE WITH A SMALL SURCHARGE IF USER REQUIRES. ALSO NEEDED IS 120V
SINGLE PHASE FOR THE BOOTH LIGHTS (WHICH ARE PRE-WIRED)
NONE - SELF CONTAINED,
RECIRCULATING WITH FILTERS
80-110PSI COMPRESSED AIR
SERVICE DROP
GFCI, NEW UNITS. CONTRACTOR TO
PROVIDE FINAL CONNECTION FOR
ELECTRICAL. ERECTED WITHIN THE SPACE.
142 BONDING / LAYUP AREA INDUSTRIAL WALK-IN OVEN BENKO SAHARA INDUSTRIAL OVENS
CUSTOM BUILT TO CLIENT SPECIFICATION
7' H x 16' D x 7' W 3 PHASE / 240 OR 480V STANDARD. ALTERNATE VOLTAGES AVAILABLE NONE NONE ASSUME GOVERNMENT WILL FURNISH
AN ELECTRIC OVEN. NO GAS OR
EXHAUST REQUIRED.
GFCI, NEW UNITS. CONTRACTOR TO
PROVIDE FINAL CONNECTION FOR
ELECTRICAL. SINGLE UNIT, INSTALLED
CONSTRUCTED.
141 PANEL SPRAY ROOM PAINT SPRAY BOOTH INCLUDING PACKAGED HVAC SYSTEM AS
SHOWN IN SPEC 11 52 00
CONFIGURATION OF PACKAGED HVAC
EQUIPMENT AS SPECIFIED IN SPEC 11 52
SEE SPEC 11 52 00 DEDICATED HVAC SYSTEM
DESIGNED AND SUPPLIED BY THE
SPRAY BOOTH VENDOR
BREATHING AIR SERVICE DROP,
COMPRESSED AIR SERVICE DROP,
NATURAL GAS
CFCI
117 LAUNDRY / RESPIRATOR ROOM RESPIRATOR WASHER AMERICAN AIRWORKS / GS2400 66" H x 26.5" D x 26" W 400#
5FT CORD. NEMA 5-15P 15A 120VAC / 1 PH / 60HZ / 9A 'CONNECT TO 20A BREAKER' NONE 40-75 PSI HW/CW FLOOR SINK, INDIRECT DRAIN TO SANITARY
GFCI, NEW UNITS. CONTRACTOR TO
PROVIDE FINAL CONNECTION FOR
ELECTRICAL AND PLUMBING. SINGLE UNIT,
INSTALLED CONSTRUCTED.
130 HAZMAT STG./DISPENSARY MOBILE STORAGE N/A 8'-10 1/2" W X 27' - 11 1/4" L NONE NONE NONE MECHANICALLY-ASSISTED WITH
SURFACE MOUNTED TRACKS. REFER TO
SPECIFICATION 10 56 26.13 MOBILE
STORAGE SHELVING
(MECHANICALLY-ASSISTED) FOR
ADDITIONAL INFORMATION.
CFCI
130 HAZMAT STG./DISPENSARY FLAM LOCKERS N/A 3'W X 5'L X 6'H NONE NONE NONE GFGI
130 HAZMAT STG./DISPENSARY CORROSIVE LOCKER N/A 3'W X 5'L X 5'H NONE NONE NONE GFGI
A
M E
N D
M E
N T
-2
-2
-2
-2
A
M E
N D
M E
N T
-0
-2
-0
-2
FOR INFORMATION ONLY:
THIS NOTE IS RELATED TO THE SMALL PARTS PAINT BOOTH IN ROOM 141. IT IS THE INTENT
OF THE GOVERNMENT TO HAVE THE SMALL PARTS PAINT BOOTH IN ROOM 141 PROVIDED
AND INSTALLED BY THE CONTRACTOR.
V F
D V
F D
VFD VFD
VFDVFD
VFDVFD
263 SF
MECH ROOM
541 SF
CTK
149C
808 SF
METALS TECH STAFF
29 SF
JAN.
56 SF
UNISEX RR
249 SF
MEN SHOWER/
LOCKER
150A
187 SF
WOMEN SHOWER/
LOCKER
150B
690 SF
ELECTRIC
3306 SF
MECHANICAL
61 SF
LO UNISEX RR
62 SF
LO UNISEX RR
265 SF
HOPPER
165 SF
HALLWAY
113 SF
LO COMM
697 SF
FIRE
29 SF
JAN
OMAX WATER
JET CUTTER
MACHINE
ACCY
TOOL
BOX
MACHINE
ACCY
TOOL
BOX
MACHINE
ACCY
TOOL
BOX
HAAS VF4 CNC
MILL
MACHINE SHOP
TABLE
HASS TL2
CNC LATHE
LARGE
CLAUSING
LATHE
MANUAL
HARDINGE
METAL
LATHE
SMALL
CLAUSING
LATHE
MACHINE
ACCY
TOOL
BOX
LARGE
CLAUSING
MILL
SMALL
CLAUSING
MILL
STAND UP
DRILL PRESS
BELT
SANDER/BURR
KING
LARGE
GRINDER/WIRE
WHEEL
BALDOR
GRINDER
TURRET SHEET
METAL PUNCH
BALDOR
BUFFING
WHEEL
SNAP ON
SAND
BLASTER
LARGE
ARBOR
PRESS
DEBURR
SHAKER
MACHINE
TABLE/SENSITIVE
DRILL
PRESS/HARDNESS
TESTER
56 SF
UNISEX RR
M A
T C
H
LI
N E
S E
E A
1/ A
1C
MATCHLINE
SEE A1/A101C
MATCHLINE
SEE A1/A101C
MATCHLINE
SEE A1/A101D
MATCHLINE
SEE A1/A101D
M A
T C
H
LI
N E
S E
E A
1/ A
1A
M A
T C
H
LI
N E
S E
E A
1/ A
1A
FLAM LOCKER
FLAM LOCKER
18' - 8" 18' - 6"
37' - 2"
3' - 4" 18' - 0" 10' - 0" 3' - 4" 3' - 4" 9' - 0" 6' - 4" 16' - 0" 6' - 4" 43' - 4" 3' - 4" 11' - 4" 8' - 0" 7' - 4" 8' - 0" 7' - 4"
11 12 1714
B
F
C
E
15 18
5209 SF
METALS TECH SHOP -
MACHINE
149A
156 SF
HALLWAY
140A
1"
72' - 0" 32' - 0" 30' - 4" 23' - 8"
134A
133A
149C
124C
149B
150A 150B
149A
135133B
134B
140B
7A-401
B7
A-401
B9
B.2
D
G
10 13 16
G.5
G.2
M2A
3'
4'
W1 W1
A1
A-305
M3A
M3A
M3A
M3AM3A
M3AM3A
3' - 4" 4' - 8"
M1B
M1F
M1C
M1F
M1F
M1F
M1D
M1F
M1E
M1D
M1D M1B
M1B
M1A
M1A
M1A
M1B
M1F
M1F
M1B M1B
S1C S1C
M1F
S1H S1H
S1HS1C
F1EF1E
S1E
M1D
M1D
M1E
M1D
M1D
M1D
M1E
M1F
A-401
F7
A-501
D7
A-501
D4
3'
2'
3'
8'
5'
3'
8'
A3
A-314
A-521
A7
11' - 6 1/2"
2' - 8" 39' - 4"
17' - 3" 9' - 4" 8' - 0"
8'
8'
72' - 7 1/4"
6'
6'
2'
2'
7' - 0"
11' - 0 5/8" 6' - 6"
20 TYP.
A-501
F1SIM.
23 23 23
4 1/4"
E Q
E Q
PARTITION LEGEND
GENERAL SHEET NOTES
FLOOR PLAN LEGEND & SHEET NOTES
A. ALL EXTERIOR WALLS TO BE DIMENSIONED TO THE FACE OF SHEATHING OR CONCRETE U.O.N.
B. ALL INTERIOR WALLS TO BE DIMENSIONED TO THE FACE OF STUD U.O.N.
C. ALL INTERIOR PARTITIONS SHALL BE AS TAGGED. SEE PARTITION TYPE DETAILS FOR MORE
INFORMATION. SEE ENLARGED PLANS FOR PARTITION TAGS NOT IDENTIFIED ON OVERALL FLOOR
PLANS.
D. PROVIDE 5/8" CEMENTITIOUS BACKER UNITS IN LIEU OF TYPICAL GWB AT ALL TILE AREAS INCLUDING, BUT NOT LIMITED TO:
A. BATHROOMS
B. SHOWER AREAS
E. PROVIDE 5/8" MOISTURE RESISTANT GWB ABOVE TILE IN WET AREAS, AND IN LOCKER ROOMS.
F. EXTEND SMOKE BARRIER PARTITION WALLS TO BOTTOM OF UPPER FLOOR STRUCTURE.
G. EQUIPMENT IS SHOWN AND LABELED IN DRAWINGS IN ROOMS 117, 130, 141-143, 149A, AND 149B FOR
PLANNING PURPOSES ONLY. REFER TO A-011 FOR GOVERNMENT FURNISHED EQUIPMENT (GFE)
SCHEDULES.
H. REFER TO DETAIL F-1 ON A-002 FOR TYPICAL DOOR INSTALLATION CLEARANCES.
I. DOORS TO BE PLACED TO THE NEAREST MASONRY JOINT PER THE PLAN DIMENSIONS, ALLOWING FOR
ABA COMPLIANCE PER SHEET A-002.
J. COORDINATE DIMENSIONED LOCATION OF A/V EQUIPMENT, TACK BOARDS, AND WHITE BOARDS WITH
OWNER PRIOR TO INSTALLATION.
K. COORDINATE DIMENSIONED LOCATION OF ALL SHOP EQUIPMENT W/ OWNER PRIOR TO INSTALLATION.
L. UNDERSLAB INSULATION: PROVIDE VAPOR BARRIER THROUGHOUT. PROVIDE 2" MIN. THICK RIGID
UNFACED INSULATION AT ALL PERIMETER EXTERIOR BUILDING WALLS FOR A MIN. DISTANCE OF 2'-0", OR
AS SHOWN ON DRAWINGS.
NON-RATED WALL SYSTEM
1-HOUR RATED WALL SYSTEM
SMOKE RATED WALL SYSTEM
PRECAST OR C.I.P. CONCRETE WALL SYSTEM
CONCRETE MASONRY UNIT WALL SYSTEM
NOTE: REFER TO PARTITION TAGS ON PLANS AND PARTITION TYPE DETAILS.
SEE SHEETS A006 AND A007 FOR PARTITION TYPES.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
R H
A M
M E
T T
N A
O F
IL
E
N O
A
W -2
-R
-2
BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_A_R19.rvt
2/9/2022 8:42:10 AM
A101E
F
IR
S T
F L
O O
R P
L A
N
A R
E A
E
F Y
F
-2 F
O R
M A
L T
R A
IN
IN
G U
N
IT
F
T U
M
F
E S
T G
E R
R T
O M
E I
S G
R O
E T
H E
-2
-2
L O
W O
B S
E R
V A
B L
E C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
L
O C
R F
N
KEY PLANSCALE: 1/8" = 1'-0"
A1
FIRST FLOOR PLAN - AREA E
SCALE: = 1'-0"
0 8 168
1/8"
KEYNOTE LEGEND
KEYNOTE COMMENT
6 CHAINLINK METAL CAGE WITH SLIDING PERSONNEL DOOR. SEE SHEET A-521.
7 EXPANSION JOINT
15 WHITE BOARD - 96"W x 48"H
18 S.S. CORNER GUARD ON CMU WALLS
19 MOP AND BROOM HOLDER WITH UTILITY SHELF
20 BOLLARDS, TYP.
23 PAINT FIRST 6'-0" OF STEEL COLUMNS SAFETY YELLOW, TYP.
A
M E
N D
M E
N T
-2
-2
-2
-2
A
M E
N D
M E
N T
-3
-2
-3
-2
A
M E
N D
M E
N T
-0
-2
-0
-2
3 3
BA
4 7
A
B
C
E
A-404
A-404
C1
B1
A-404 B8
A-404C8
B6
251 SF
WOMEN RR
231 SF
WOMEN CLEAN
LOCKER ROOM
164 SF
WOMEN SHWR
531 SF
MEN DIRTY LOCKER
ROOM
269 SF
WOMEN DIRTY
LOCKER ROOM
342 SF
LAUNDRY /
RESPIRATOR ROOM
305 SF
MEN RR
376 SF
MEN SHWR
472 SF
MEN CLEAN LOCKER
ROOM
C6
B7
C4
HI/LO
EWC
TA-2
TA-7
TA-1
TA-15
2' - 9 3/8" 1' - 6 1/2" 3' - 1 1/2" 2' - 10 7/8" 3' - 9 1/8"
TA-7TA-7
TA-6 TA-6
TA-1
TA-7
TA-2
TA-15
TA-7 TA-7
TA-11
TA-6TA-6
TA-9
TA-15
TA-15
TA-15
TA-15
TA-15
TA-15
TA-9
7' - 2" 6' - 4"
25' - 4 1/2"
BENCH, TYP.
5' - 0 3/4" 10' - 4" 5' - 0"
E1
A-304
A-402 A1
TA-6
TA-5
TA-6
TA-6
A-405A1 A7
5' - 1 1/4"
A5
A-404C8
SIM
A-405
C7
E5
E7
E1
A.5
B.2
D
/4
1'
/4
5'
/8
8' - 1 3/8" 5' - 4"
/4
/8
2'
3'
3'
3'
3'
/2
3'
3'
6' - 1 1/2"
5' - 6 1/8" 7' - 2" 6' - 3"
6' - 9 7/8" 27' - 0 3/4"
48"x30" CLEAR
FLOOR SPACE AT
LAVATORY, TYP.
TA-4
3' - 5"
3'
2'
4'
2'
/2
2'
6'
3'
/4
8'
6' - 11" 1' - 10"
3' - 9 1/8"
4' - 11 1/8"
TA-15TA-15
TA-15 TA-15
A-405
C1
A-405C5
A-403
A1
A7
TA-18
53 SF
JAN
A-404 F9
TA-20
TA-16
TA-16
TA-15
TA-16
TA-15
TA-16
TA-15TA-16
TA-15TA-16
A1
A-314
3' - 4" 8"
113A
113B
114A
114B
5' - 0 1/8"
E Q
5'
E
Q . 1' - 9"
EQ. EQ.
3'
3'
3' - 0"
3'
3'
7' - 0" 7' - 0" E Q
E
Q
7' - 0" 7' - 0"
3'
4'
1'
7'
12' - 5" 3' - 0" 3' - 0" 5' - 0"
3' - 6"3' - 1"3' - 1"2' - 6" 3' - 1"
1' - 11 7/8"
5' - 0" ø
5' - 0" ø
5' - 0" ø
5' - 0" ø
5' - 0" ø 5' - 0" ø
7'
5' - 0" ø
11' - 4"
15' - 10" 5'-0" CLEAR
6' - 4"
8'
5'
/4
10' - 4 1/4"
ALIGN
ALIGN
3' - 4 3/4"
5'
3'
/2
3'
3'
5'
1'
/8
S1A
F1C
S1D
F1CF1C
F1CF1C
F1E
S1B
S1H
S1J
S1H
S1H
S1H
S1C
S1C
S1C
S1E
S1D
S1G
S1H
S1H
S1G
S1G
F1E
M1F
S3A
S1E
S1A
S1E
F1EF1E
S1E
S1E
S1A
S1C
F1EF1E
S1A
S1B
S1E
F1C F1C
S1E
S1E
S1E
S1E
S3A
S1E
S1H
F1B
S1C
S1C
S1C
S1C
S1E
S1E
S1E
S1D
M1B
S3A
S1A
S1E
F1E F1E
F1E
F1E
S1C
S1H
F1C
S1HS1C
S1J
TA-11
TA-8
TA-8
TA-8
TA-12
TA-12
TA-12
TA-12
TA-12
TA-12
TA-12
TA-12
TA-12
TA-8
TA-10
BENCH, TYP.
ABA BENCH
BENCH, TYP.
BENCH, TYP. ABA BENCH
BENCH, TYP.
ABA
BENCH
BENCH, TYP.
BENCH,
TYP.
BENCH, TYP. BENCH, TYP.
BENCH, TYP.
ABA
BENCH
BENCH, TYP.
BENCH, TYP.
ABA
BENCH
BENCH,
TYP.
TA-13
TA-13
TA-13
TA-12
TA-13
TA-13
TA-13
TA-13
TA-13
TA-13
TA-13
TA-8
TA-16
TA-16
TA-16
TA-5
TA-5
TA-5
TA-21
TA-21TA-21
TA-21
TA-21TA-21
B
62 SF
LO UNISEX RR
29 SF
JAN
61 SF
LO UNISEX RR
3' - 10 7/8" 6' - 0 3/8"
TA-2
TA-1
TA-7
6'
/4
5'
/8
5'
7 5/8" 9' - 11"
1'
TA-2
TA-1
TA-7
TA-5
TA-6
TA-6
A-404
E1
E3
E5
B.2
7'
1"
5/
8"
1'
TA-5
TA-15
TA-15
TA-15
TA-10
TA-10
M1E
M3A
M1D
M1D
M1D
M3A
M1F
M1B
M3A
M3A
TA-8
TA-8
TA-21
TA-21
B
29 SF
JAN.
56 SF
UNISEX RR
165 SF
HALLWAY
TA-7
TA-2
TA-7
TA-2
TA-1
1'
1/ 8"
1'
7 5/8" 8' - 0 3/8" 8' - 0"
5'
/2
8'
7'
/8
6' - 5 3/8" 7 5/8"
HI/LO
EWC
TA-6
TA-1
TA-6
A-404
E6
E8
F1
TA-5
56 SF
UNISEX RR
B.2
TA-15
TA-15
4'
3'
1'
3'
TA-10
1'
/8
3'
2"
2' - 0 3/8"
149A
M1D
M1D
M1E
M1D
M1D
M3A
M1E
M3A
M1D
M1E
M3A
TA-8
TA-8
TA-10
TA-5
TA-21
TA-21
TA-1 36" CONCEALED MOUNTING GRAB BAR
RESTROOM ACCESSORY SCHEDULE
DESCRIPTIONMARK COMMENTS
A. HANDICAP ACCESSIBILITY IN ACCORDANCE WITH ABA STANDARDS.
B. INSULATE EXPOSED HOT WATER SUPPLY AND DRAIN PIPES PER ABA AND ADA REQUIREMENTS.
C. ACCESSORIES ARE CONTRACTOR FURNISHED CONTRACTOR INSTALLED (CFCI) UNLESS OTHERWISE
NOTED.
D. PROVIDE BLOCKING IN WALLS FOR ACCESSORIES.
E. SEE SPECIFICATION 10 28 13 FOR TOILET ACCESSORIES PRODUCT REQUIREMENTS.
F. SEE SHEET A002 FOR TYPICAL MOUNTING HEIGHTS.
G. SEE PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION ON PLUMBING FIXTURES.
42" CONCEALED MOUNTING GRAB BAR
SURFACE MOUNTED
30" CONCEALED MOUNTING GRAB BAR
18" CONCEALED MOUNTING GRAB BAR
PROCUREMENT
GFGI
GFGI
TA-2
TA-3
TA-4
TA-5
TA-6
TA-7
TA-8
TA-9
TA-10
TA-11
TA-12
TA-13
TA-14
TA-15
PAPER TOWEL DISPENSER
SOAP DISPENSER
TOILET TISSUE DISPENSER
WASTE RECEPTACLE
FOLDING SHOWER SEAT
MIRROR
MIRROR (CUSTOM SIZE)
SURFACE MOUNTED
SURFACE MOUNTED
SURFACE MOUNTED
SURFACE MOUNTED
CONCEALED MOUNTING
ANTI-BACTERIAL FABRIC CURTAIN
SHOWER CURTAIN ROD
SHOWER CURTAIN
SHOWER CURTAIN HOOKS
GARMENT HOOK, DOUBLE HOOK,
CONCEALED MOUNTING
TA-16
TA-17
TA-18
30" LONG, FLOOR MOUNTEDBENCH
ABA BENCH
URINAL SCREEN PARTITION
GFGI
ON RESTROOM DOORS, STALL
DOORS, AND SHOWER AREAS
PROVIDE 1 AT EVERY LATCH
SIDE OF ALL DOORS
HAND SANITIZER DISPENSER
METAL SHELF
METAL SHELF WITH 4 HOOKS AND
3 ROLLER CLIPS
TA-20
TA-19
SURFACE MOUNTED
FREE STANDING
PROVIDE AT ALL SHOWERS
NOT USED
PROVIDE 1 AT EVERY LATCH
SIDE OF ALL DOORS
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
TOILET SEAT COVER DISPENSER SURFACE MOUNTEDTA-21 CFCI
60 SF
RR
5/
8" 7'
EWC
TA-7
TA-1
TA-6
A-404 F3
F5
F7
8' - 0 3/8"
4' - 8 3/8" 3' - 4"
TA-15
TA-10
TA-2
1' - 6 3/4"
2"
M1D
M1C
M1D
M1D
M3A
M3A
TA-8
TA-5
TA-21
TA-15
TA-9
TA-12 TA-12
TA-9
TA-15
A-405F1A-405
F8
F6
F3
F5
TA-12TA-12
F10
TA-16TA-16 3' - 1 1/2"3' - 1 1/2"
/8
/8
5' - 1 1/2"
S1C
S1E
S1H
S1H
S1H
F1E
F1E
F1E
F1E
TA-13
TA-13 TA-13 TA-13
SMALL
LOCKERS AND BENCHES SCHEDULE
TYPE LOCATION
MEDIUM
BENCH
LARGE
SIZE
ROOM 117
ROOMS 118, 120, 122, 123
ROOMS 150A & 150B
QTY
N/A
ABA BENCH
12"W X 12"D X 12"H
12"W X 12"D X 36"H
48"W X 12"D X 36"H 2 STACK, 24 LOCKERS
2 STACK, 440 LOCKERS
6 STACK,150 LOCKERS
N/A
30"W X 10"D X 18"H
42"L X 20"D X 18"H
ROOMS 117, 118, 120, 122, 123, 150A, 150B
ROOMS 117, 118, 120, 122, 123, 150A, 150B
NOTE: SEE SPECIFICATIONS FOR MATERIALS, FINISHES, AND OTHER REQUIREMENTS FOR
LOCKERS AND BENCHES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
R H
A M
M E
T T
N A
O F
IL
E
N O
A
W -2
-R
-2
BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_A_R19.rvt
2/9/2022 8:43:54 AM
A-401
E N
L A
R G
E D
P L
A N
S
F Y
F
-2 F
O R
M A
L T
R A
IN
IN
G U
N
IT
F
T U
M
F
E S
T G
E R
R T
O M
E I
S G
R O
E T
H E
-2
-2
L O
W O
B S
E R
V A
B L
E C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
L
O C
R F
SCALE: = 1'-0"
0 4 84
1/4"
SCALE: 1/4" = 1'-0"
A1
ENLARGED RESTROOMS, SHOWERS & LOCKERS
SCALE: 1/4" = 1'-0"
B7
UNISEX RRS 136,138 & J.C. 137
SCALE: 1/4" = 1'-0"
B9
UNISEX RRS 145, 146, J.C. 147 & HALL
SCALE: 1/4" = 1'-0"
D7
RR 155 @ WASHRACK AREA
SCALE: 1/4" = 1'-0"
F7
WOMEN SHOWER/LOCKER 150B
MEN SHOWER/LOCKER 150A /
A
M E
N D
M E
N T
-3
-2
-3
-2
A
M E
N D
M E
N T
-0
-2
-0
-2
A.5
PRE-CAST CONCRETE PANEL
TYPE PC-1. SEE A-541 FOR
ADDITIONAL INFORMATION
STOREFRONT SYSTEM
BRICK SOLDIER COURSE BEYOND
FLUID APPLIED MEMBRANE AIR
BARRIER ON 5/8" SHEATHING
BRICK VENEER BEYOND
R-18 RIGID INSULATION
THRU-WALL FLASHING
GWB
STEEL FRAMING. REFER TO
STRUCTURAL.
GWB
SEALANT
HSS TUBE; SEE
STRUCTURAL
INSULATED LAMINATED GLASS
P.T. WOOD SHIM
BACKER ROD & SEALANT
METAL STUDS AT
24" O.C. WITH 5/8"
GWB
SEALANT
HSS TUBE; SEE
STRUCTURAL
METAL STUDS
P.T. WOOD SHIM
BACKER ROD & SEALANT
STOREFRONT SYSTEM
INSULATED LAMINATED
GLASS
SELF-ADHERING AIR BARRIER. LAP
OVER ANGLE AND TURN INTO
STOREFRONT SYSTEM OPENING TO
MAINTAIN AIR BARRIER CONTINUITY
SELF-ADHERING AIR BARRIER. LAP
OVER ANGLE AND TURN INTO
STOREFRONT SYSTEM OPENING TO
MAINTAIN AIR BARRIER CONTINUITY
SELF-ADHERING AIR BARRIER. LAP
OVER FLASHING TO MAINTAIN AIR
BARRIER CONTINUITY
2" AIR SPACE
LINE OF GWB
BEYOND
LINE OF GWB
BEYOND
LINE OF STOREFRONT JAMB
BEYOND
ALUMINUM SILL PAN FLASHING
WITH DRIP EDGE
5 1/4"
PROVIDE HORIZONTAL S.S.
ANCHORS AT 24" O.C. TYP. SEAL
ALL AROUND THE MASONRY
ANCHORS AFTER THE AB IS
PLACED.
PROVIDE WEEPS BETWEEN
PANELS
ELECTRICAL
FIXTURE
FURRING STRIP
1ST FLOOR
100' - 0"
B
STOREFRONT SYSTEM
BRICK SOLDIER COURSE
ALUMINUM SILL PAN
FLASHING WITH DRIP EDGE
FLUID-APPLIED MEMBRANE
BARRIER 8" CMU
R-18 RIGID INSULATION
PRECAST CONCRETE PANEL
TYPE PC-3, SECURED WITH S.S
STRAPS BACK TO CMU. SEE
A-541 FOR ADDITIONAL
INFORMATION
THRU WALL FLASHING
CEMENTOUS PARGING ON HIGH
IMPACT FIBERGLASS LATH
CONCRETE SPLASH BLOCK
GRADE
3" X 3" GALV. STEEL ANGLE AT
WINDOW SILL SECURED CMU
1 1/2" METAL STUDS
5/8" GWB
1/2" SOLID SURFACE
WINDOW SILL WITH
ROUNDED EDGE
GROUT CELLS SOLID
COMPRESSIBLE FILLER
INSULATING LAMINATED GLASS
P.T. WOOD SHIM
BACKER ROD & SEALANT
DOWNSPOUT BEYOND
SEALANT
LINE OF GWB BEYOND
CONCRETE SLAB - SEE
STRUCTURAL
BENTONITE WATERPROOFING - LAP AT TOP
OF CMU COURSE TO ENSURE AIR BARRIER
CONTINUITY
LAP SELF-ADHERING AIR
BARRIER OVER ANGLE AND
INTO THE WINDOW OPENING
TO ENSURE AIR BARRIER
CONTINUITY
SELF-ADHERING AIR BARRIER.
LAP OVER FLASHING TO
MAINTAIN AIR BARRIER
CONTINUITY
VAPOR BARRIER BELOW SLAB.
SEE STRUCTURAL
SPECIFICATIONS. SECURE
VAPOR BARRIER BELOW SLAB
WITH TERMINATION BAR.
1 7/8"
RIGID INSULATION TO FILL
CAVITY
PROVIDE HORIZONTAL S.S.
ANCHORS AT 24" O.C. TYP.
SEAL ALL AROUND THE
MASONRY ANCHORS
AFTER THE AB IS PLACED.
WATERPROOFING AT ALL BACK
SIDE OF CMU BELOW GRADE
DRIP EDGE
PROVIDE WEEPS BETWEEN PANELS
B
FACE OF BRICK VENEER BEYOND
R-18 RIGID INSULATION
STEEL ANGLE. REFER TO STRUCTURAL.
THRU WALL FLASHING
P.T. WOOD SHIM
BACKER ROD & SEALANT
INSULATED LAMINATED GLASS
STOREFRONT SYSTEM
CEILING AS SCHEDULED
LINE OF MULLION BEYOND
BACKER ROD & SEALANT
GWB
1 7/8"
LINE OF GWB BEYOND
FLUID-APPLIED MEMBRANE
BARRIER 8" CMU
PRECAST CONCRETE PANEL TYPE PC-1,
SECURED WITH S.S STRAPS BACK TO CMU AT 24"
O.C. SEE A-541 FOR ADDITIONAL INFORMATION
SELF-ADHERING AIR BARRIER. LAP
OVER FLASHING TO MAINTAIN AIR
BARRIER CONTINUITY
ANY THERMAL BREAKS
SHALL BE SEALED WITH
LOW PRESSURE SELF
EXPANDING FOAM SEALANT
BRICK TIE
WINDOW SHEET NOTES
A. PROVIDE S.S. BRICK PRECAST TIES AT 16" O.C. VERTICALLY AND 24" O.C.
HORIZONTALLY.
B. INSTALL MEMBRANE OVER FLASHING AND BRICK TIE PENETRATIONS
GENERAL SHEET NOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
R H
A M
M E
T T
N A
O F
IL
E
N O
A
W -2
-R
-2
BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_A_R19.rvt
2/8/2022 2:57:38 PM
A-562
W
IN
D O
W D
E T
A
IL
S
F Y
F
-2 F
O R
M A
L T
R A
IN
IN
G U
N
IT
F
T U
M
F
E S
T G
E R
R T
O M
E I
S G
R O
E T
H E
-2
-2
L O
W O
B S
E R
V A
B L
E C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
L
O C
R F
SCALE: = 1'-0"3"
SCALE: 3" = 1'-0"
A1
DETAIL AT TOWER WITH PRECAST
SCALE: 3" = 1'-0"
A5
WALL DETAIL AT WINDOW AT ADMIN
SCALE: 3" = 1'-0"
F5
TYPICAL HEAD DETAIL AT ADMIN
A
M E
N D
M E
N T
-0
-2
-0
-2
T.O. TOWER MASONRY
126' - 0"
A.5
PRE-CAST CONCRETE PANEL
TYPE PC-1. SEE A-541 FOR
ADDITIONAL INFORMATION
FLUID APPLIED MEMBRANE AIR
BARRIER / VAPOR BARRIER ON
5/8" SHEATHING
R-18 RIGID INSULATION
2" AIR SPACE
6" METAL STUDS
ATTACHMENT PLATE;
SEE STRUCTURAL
MESH CELL AIR VENT @
VERTICAL MASONRY JOINTS
STOREFRONT SYSTEM
SEALANT (CONT.)
GWB
STEEL COLUMN BEYOND
(PAINTED) - SEE STRUCTURAL
INSULATED LAMINATED
GLASS
HSS BEAM - SEE
STRUCTURAL
SELF-ADHERING AIR
BARRIER. LAP OVER
ANGLE AND TURN IN AT
OPENING FOR AIR
BARRIER CONTINUITY
PRECAST PARAPET SILL; SEE
SHEET A-541 FOR ADDITIONAL
INFORMATION
BRICK VENEER WITH 2" AIR
SPACE AND R-18 RIGID
INSULATION
DRIP EDGE
P.T. WOODSHIM
BACKER ROD
& SEALANT
FLUID APPLIED MEMBRANE AIR
BARRIER / VAPOR BARRIER ON
FACE 5/8" SHEATHING
ALUMINUM SILL PAN
FLASHING WITH DRIP
EDGE
FACTORY FINISHED STEEL
PLATE SECURED TO
STRUCTURE. COLOR TO MATCH
ADJACENT STOREFRONT
SYSTEM AND TOWER SOFFIT
PANELS
BRICK SOLDIER COURSE
SEALANT
HSS BEAM; SEE
STRUCTURAL
METAL STUDS @
24 " O.C. WITH
5/8" GWB
P.T. WOOD SHIM
BACKER ROD & SEALANT
STOREFRONT SYSTEM
LINE OF GWB BEYOND
LINE OF STOREFRONT JAMB
BEYOND
BRICK VENEER BEYOND
THRU-WALL FLASHING
INSULATED LAMINATED
GLASS
SELF-ADHERING AIR BARRIER. LAP
OVER ANGLE AND TURN INTO
STOREFRONT SYSTEM OPENING TO
MAINTAIN AIR BARRIER CONTINUITY
SELF-ADHERING AIR BARRIER. LAP
OVER FLASHING TO MAINTAIN AIR
BARRIER CONTINUITY
PROVIDE HORIZONTAL S.S.
ANCHORS AT 24" O.C. TYP.
HSS BEAM - SEE
STRUCTURAL
SELF-ADHERING AIR BARRIER. LAP
OVER FLASHING TO MAINTAIN AIR
BARRIER CONTINUITY
THRU-WALL FLASHING
LIGHT FIXTURE.
REFER TO
ELECTRICAL
FURRING STRIP
1/2" DIAMETER ANCHORS; SEE
STRUCTURAL
1ST FLOOR
100' - 0"
A.5
STOREFRONT SYSTEM
BRICK SOLDIER COURSE BEYOND
STEEL FRAMING. REFER
TO STRUCTURAL.
INSULATED LAMINATED GLASS
P.T WOOD SHIM
BACKER ROD & SEALANT
SELF-ADHERING AIR BARRIER. LAP
OVER ANGLE AND TURN INTO
STOREFRONT SYSTEM OPENING TO
MAINTAIN AIR BARRIER CONTINUITY
ALUMINUM SILL PAN FLASHING
WITH DRIP EDGE
1/2" SOLID SURFACE WINDOW
SILL WITH ROUNDED EDGE
SEALANT
LINE OF GWB BEYOND
R-18 RIGID INSULATION
PRECAST CONCRETE PANEL
TYPE PC-3, SECURED WITH S.S
STRAPS BACK TO CMU. SEE
A-541 FOR ADDITIONAL
INFORMATION
CONTINUOUS THRU WALL FLASHING
CEMENTOUS PARGING ON HIGH
IMPACT FIBERGLASS LATH
GRADE
CONCRETE SLAB - SEE
STRUCTURAL
BENTONITE WATERPROOFING - LAP AT TOP
OF CMU COURSE TO ENSURE AIR BARRIER
CONTINUITY
SELF-ADHERING AIR BARRIER.
LAP OVER FLASHING TO
MAINTAIN AIR BARRIER
CONTINUITY
2" AIR SPACE
FLUID APPLIED MEMBRANE AIR
BARRIER / VAPOR BARRIER ON
5/8" SHEATHING
GWB
METAL STUDS
5"
CONTINUOUS 2" RIGID
INSULATION UNDER ENTIRE
ENTRY VESTIBULE SLAB
VAPOR BARRIER BELOW
SLAB. SEE STRUCTURAL
SPECIFICATIONS.
PROVIDE HORIZONTAL S.S.
ANCHORS AT 24" O.C. TYP.
DRIP EDGE
WINDOW SHEET NOTES
A. PROVIDE S.S. BRICK PRECAST TIES AT 16" O.C. VERTICALLY AND 24" O.C.
HORIZONTALLY.
B. INSTALL MEMBRANE OVER FLASHING AND BRICK TIE PENETRATIONS
GENERAL SHEET NOTES
STOREFRONT SYSTEM
SHIM AS NECESSARY
SEALANT AND BACKER ROD
BOTH SIDES
EXTERIOR BRICK VENEER
5/8" GWB OVER 7/8" METAL
FURRING
CORNER BEAD
FLUID-APPLIED MEMBRANE
BARRIER OVER CMU
SUPPORT STEEL ANGLE AT
OPENING, REFER TO STRUCTURAL
R-11 RIGID INSULATION
SEALANT
GLAZING PER SCHEDULE
SEALANT
LINE OF MULLION BEYOND
FURRING WALL WHERE
SCHEDULED, REFER TO
FLOOR PLANS FOR DETAILS.
NOTE:
ALIGN FRONT OF
STOREFRONT FRAME WITH
BACK OF BRICK
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
R H
A M
M E
T T
N A
O F
IL
E
N O
A
W -2
-R
-2
BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_A_R19.rvt
2/8/2022 2:58:30 PM
A-563
W
IN
D O
W D
E T
A
IL
S
F Y
F
-2 F
O R
M A
L T
R A
IN
IN
G U
N
IT
F
T U
M
F
E S
T G
E R
R T
O M
E I
S G
R O
E T
H E
-2
-2
L O
W O
B S
E R
V A
B L
E C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
L
O C
R F
SCALE: = 1'-0"
0 8 168
1/8"SCALE: 3" = 1'-0"
A1
EAST TOWER CLERESTORY - PRECAST DETAIL
SCALE: 3" = 1'-0"
A6
TYP. TOWER BASE DETAIL
SCALE: 3" = 1'-0"
C1
STOREFRONT JAMB - BRICK
A
M E
N D
M E
N T
-3
-2
-3
-2
A
M E
N D
M E
N T
-0
-2
-0
-2
2 2
DOOR SCHEDULE SHEET NOTES
A. ALL EXTERIOR DOORS, SWING AND OVERHEAD, TO BE INSULATED.
B. ALL FIRE RATED DOORS, SWING, OVERHEAD AND SMOKE DOORS, AS SCHEDULED IN FIRE RATED PARTITIONS, TO BE LABELED BY MANUFACTURER AND CONNECTED TO THE FIRE ALARM SYSTEM.
C. ALL SMOKE RATED DOORS, SWING AND OVERHEAD, TO BE PROVIDED GASKETING AS SCHEDULED.
D. ALL EXTERIOR SWING DOORS TO RECEIVE THRESHOLDS AND WEATHERSTRIPPING.
E. ALL DOORS, SWING AND OVERHEAD, AS SCHEDULED IN STC RATED PARTITIONS, TO BE INSULATED FOR
SOUND AND PROVIDED WITH DOOR SEALS.
F. OVERHEAD DOORS, INCLUDING SHROUDS AND OTHER COMPONENTS, TO BE FACTORY FINISHED.
G. SEE SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE.
H. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL MOTORS AND CONTROLS
I. COORDINATE WITH ELECTRICAL AND SECURITY DRAWINGS FOR ALL CONNECTIONS AND CONTROLS FOR
ACCESS CONTROL AND SECURITY
J. COORDINATE WITH FIRE PROTECTION FOR ALL CONNECTIONS TO FIRE ALARM SYSTEM.
K. CONTRACTOR TO PROVIDE DOORS AND HARDWARE FOR AIR SHOWER ROOMS AS SCHEDULED. COORDINATE
CONTROLS AND HARDWARE WITH AIR SHOWER VENDOR.
L. COORDINATE DOOR ASSEMBLIES AND HARDWARE FOR SECURE STORAGE REQUIREMENTS, SEE SHEET A-004.
M. ALL DOORS AND FRAMES TO BE HEAVY DUTY.
N. AT INTERIOR DOORS, PROVIDE THRESHOLD AT ALL CHANGES IN FLOOR FINISH. SEE DRAWING I-601 FOR
DETAILS.
O. FOR DOORS 126A, 128A, 128E, 131A & 143B PROVIDE EXPLOSION PROOF MOTOR AS SPECIFIED.
GENERAL SHEET NOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
R H
A M
M E
T T
N A
O F
IL
E
N O
A
W -2
-R
-2
BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_A_R19.rvt
2/8/2022 7:39:18 PM
A-602
D O
O R
S C
H E
D U
L E
F Y
F
-2 F
O R
M A
L T
R A
IN
IN
G U
N
IT
F
T U
M
F
E S
T G
E R
D S
O U
D Y
S G
R O
E T
H E
-2
-2
L O
W O
B S
E R
V A
B L
E C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
L
O C
R F
DOOR SCHEDULE
DOOR NO. PAIR
DOOR DIMENSIONS
DOOR TYPE
MATERIALS
FIRE RATING HARDWARE SET
FRAME DETAILS
COMMENTSWIDTH HEIGHT THICKNESS MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB THRESHOLD
128E No 8' - 0" 10' - 0" 3" OH STL FACTORY PT 45 MIN. 13 OH STL PT E8/A-554 A8/A-554 STC 21, MOTORIZED, INSULATED, GASKETED
129 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 45 MIN. 17 F2 HM PT E2/A-552 A2/A-552 STC 45, GASKETED, INSULATED
130A Yes 6' - 0" 7' - 0" 1 3/4" D2 HM PT 45 MIN. 18 F3 HM PT E2/A-552 A2/A-552 GASKETED, STC 45
130B Yes 6' - 0" 7' - 0" 1 3/4" D2 HM PT 45 MIN. 18 F3 HM PT E2/A-552 A2/A-552 GASKETED, STC 45
131A No 8' - 0" 10' - 0" 3" OH STL FACTORY PT 45 MIN. 13 OH STL PT E8/A-554 A8/A-554 STC 21, MOTORIZED, INSULATED, GASKETED
131B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 45 MIN. 5 F2 HM PT E2/A-552 A2/A-552 STC 45, INSULATED, GASKETED
131C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
131D No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
132 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 45 MIN. 17 F2 HM PT E2/A-552 A2/A-552 STC 45, INSULATED, GASKETED
133A No 10' - 0" 10' - 0" 3" OH STL FACTORY PT 13 OH STL PT E1/A-554 A8/A-554 A1/A-554 MANUALLY OPERATED, INSULATED
133B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
134A Yes 6' - 0" 7' - 0" 1 3/4" D2 HM PT 27 F3 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
134B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 29 F2 HM PT E2/A-552 A2/A-552
135 Yes 6' - 0" 7' - 0" 1 3/4" D2 HM PT 27 F3 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
136 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 23 F2 HM PT E2/A-552 A2/A-552
137 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 11 F2 HM PT E2/A-552 A2/A-552 UNDERCUT
138 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 23 F2 HM PT E2/A-552 A2/A-552
139 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 6 F2 HM PT E2/A-552 A2/A-552 GASKETED, UNDERCUT
140A Yes 6' - 0" 7' - 0" 1 3/4" D2 HM PT SMOKE 25 F3 HM PT E2/A-552 A2/A-552 GASKETED
140B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 26 F2 HM PT E2/A-552 A2/A-552 GASKETED
141A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 5 F2 HM PT E2/A-552 A2/A-552 SECURE AREA. STC 30. GASKETED
141B No 8' - 0" 10' - 0" 3" OH STL FACTORY PT SMOKE 13 OH STL PT E8/A-554 A8/A-554 SECURE AREA. STC 21. GASKETED.
MOTORIZED. INSULATED.
141C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 5 F2 HM PT E2/A-552 A2/A-552 SECURE AREA. STC 30. GASKETED
141D No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 15 F2 HM PT E2/A-552 A2/A-552 SECURE AREA. STC 30. GASKETED
141E No 8' - 0" 10' - 0" 3" OH STL FACTORY PT 14 OH STL PT E8/A-554 A8/A-554 SECURE AREA. STC 21. GASKETED.
INSULATED.
142A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 5 F2 HM PT E2/A-554 A2/A-554 SECURE AREA. STC 30. GASKETED
142B No 8' - 0" 10' - 0" 3" OH STL FACTORY PT SMOKE 13 OH STL PT E8/A-554 A8/A-554 SECURE AREA. STC 21. GASKETED.
MOTORIZED. INSULATED.
142C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 5 F2 HM PT E2/A-552 A2/A-552 SECURE AREA. STC 30. GASKETED
142D No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 15 F2 HM PT E2/A-552 A2/A-552 SECURE AREA. STC 30. GASKETED
142E No 12' - 0" 10' - 0" 3" OH STL FACTORY PT 14 OH STL PT E8/A-554 A8/A-554 SECURE AREA. STC 21. GASKETED.
INSULATED.
143A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 5 F2 HM PT E2/A-552 A2/A-552 SECURE AREA. STC 30. GASKETED
143B No 8' - 0" 10' - 0" 3" OH STL FACTORY PT SMOKE 13 OH STL PT E8/A-554 A8/A-554 SECURE AREA. STC 21. GASKETED.
MOTORIZED. INSULATED.
143C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 5 F2 HM PT E2/A-552 A2/A-552 SECURE AREA. STC 30. GASKETED
144 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 15 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
145 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 23 F2 HM PT E2/A-552 A2/A-552 STC 30. PROVIDE DOOR SEALS
146 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 23 F2 HM PT E2/A-552 A2/A-552 STC 30. PROVIDE DOOR SEALS
147 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 11 F2 HM PT E2/A-552 A2/A-552 UNDERCUT
148 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 4 F2 HM PT E2/A-552 A2/A-552 STC 30. PROVIDE DOOR SEALS
149A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 28 F2 HM PT E2/A-552 A2/A-552 GASKETED, STC 30
149B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
149C No 12' - 0" 10' - 0" 3" OH STL FACTORY PT 13 OH STL PT E1/A-554 A8/A-554 A1/A-554 MANUAL, INSULATED, WEATHERSTRIP
149D No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 19 F2 HM PT E2/A-552 A2/A-552
149E No 14' - 0" 20' - 0" 3" OH STL FACTORY PT 13 OH STL PT E1/A-554 A8/A-554 A1/A-554 MOTORIZED, INSULATED, WEATHERSTRIP
149F No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
149G No 0' - 0" 0' - 0" - - - - - STL PT WALL OPENING FOR WELD CURTAIN
150A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552 STC 30
150B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552 STC 30
151 Yes 6' - 0" 7' - 0" 1 3/4" D2 HM PT 21 F3 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
152 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 2 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
153 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 6 F2 HM PT E2/A-552 A2/A-552 GASKETED
154 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 6 F2 HM PT E2/A-552 A2/A-552 GASKETED, UNDERCUT
155 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 23 F2 HM PT E2/A-552 A2/A-552 STC 30. PROVIDE DOOR SEALS
156 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 4 F2 HM PT E2/A-552 A2/A-552 STC 30. PROVIDE DOOR SEALS
157 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
158A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 45 MIN. 15 F2 HM PT E2/A-552 A2/A-552 STC 45, INSULATED, GASKETED
158B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
158C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
158D Yes 6' - 0" 7' - 0" 1 3/4" D2 HM PT 45 MIN. 18 F3 HM PT E2/A-552 A2/A-552 GASKETED
DOOR SCHEDULE
DOOR NO. PAIR
DOOR DIMENSIONS
DOOR TYPE
MATERIALS
FIRE RATING HARDWARE SET
FRAME DETAILS
COMMENTSWIDTH HEIGHT THICKNESS MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB THRESHOLD
100A Yes 6' - 0" 7' - 1 1/2" D5 AL/GL ANOD 1 F4 ALUM ANOD E1/A-551 A1/A-551 C1/A-551 WEATHERSTRIP; DOOR THICKNESS
VARIES BY MANUF.
100B Yes 6' - 0" 7' - 0" 1 3/4" D6 HM PT 3 F5 HM PT E4/A-552 A4/A-552
101A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 2 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
102 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 4 F1 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS
103 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 4 F1 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS
104 No 3' - 0" 7' - 0" 1 3/4" D3 HM PT 11 F1 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS, UNDERCUT
105 No 3' - 0" 7' - 0" 1 3/4" D3 HM PT 11 F1 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS, UNDERCUT
106 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 4 F1 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS
107 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 12 F1 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS
108A Yes 6' - 0" 7' - 2 1/2" 1 3/4" D5 AL/GL ANOD 10 F4 ALUM ANOD E1/A-552 A1/A-552 C1/A-552 COORD. WITH AIR SHOWER VENDOR.
DOOR THICKNESS VARIES BY
MANUFACTURER
108B Yes 6' - 0" 7' - 0" 1 3/4" D5 AL/GL ANOD 10 F4 ALUM ANOD E3/A-552 A3/A-552 C3/A-552 COORD. WITH AIR SHOWER VENDOR.
DOOR THICKNESS VARIES BY
MANUFACTURER
110 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 6 F1 HM PT E4/A-552 A4/A-552 GASKETED, UNDERCUT
111 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT SMOKE 6 F1 HM PT E4/A-552 A4/A-552 GASKETED
112 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 11 F1 HM PT E4/A-552 A4/A-552 UNDERCUT
113A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS
113B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552
114A No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS
114B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552
115 Yes 6' - 0" 7' - 0" 1 3/4" D6 HM PT 8 F5 HM PT E4/A-552 A4/A-552 STC 30. PROVIDE DOOR SEALS
116 No 3' - 0" 7' - 2 1/2" 1 3/4" D4 AL/GL ANOD 7 F6 ALUM ANOD E1/A-552 A1/A-552 C1/A-552 COORD. WITH AIR SHOWER VENDOR.
DOOR THICKNESS VARIES BY
MANUFACTURER
117 No 3' - 0" 7' - 0" 1 3/4" D4 AL/GL ANOD 7 F6 ALUM ANOD E3/A-552 A3/A-552 C3/A-552 COORD. WITH AIR SHOWER VENDOR.
DOOR THICKNESS VARIES BY
MANUFACTURER
118 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552
119 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552
120 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552
121 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552
122 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552
123 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 9 F1 HM PT E4/A-552 A4/A-552
124A No 8' - 0" 10' - 0" 3" OH STL FACTORY PT 13 OH STL PT A5/A-554 A8/A-554 A1/A-554 MANUAL OPERATION, INSULATED, WEATHERSTRIP, STC 21
124B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
124C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 2 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
125 No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 45 MIN. 17 F2 HM PT E2/A-552 A2/A-552 GASKETED, INSULATED, STC 45
126A No 8' - 0" 10' - 0" 3" OH STL FACTORY PT 45 MIN. 13 OH STL PT E8/A-554 A8/A-554 STC 21, MOTORIZED, INSULATED, GASKETED
126B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 45 MIN. 5 F2 HM PT E2/A-552 A2/A-552 STC 45, INSULATED, GASKETED
126C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
126D No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
127A No 8' - 0" 10' - 0" 3" OH STL FACTORY PT 13 OH STL PT E5/A-554 A8/A-554 SECURE STORAGE, INSULATED
127B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 5 F2 HM PT E2/A-552 A2/A-552 SECURE STORAGE
127C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 SECURE STORAGE, INSULATED, WEATHERSTRIP
128A No 8' - 0" 10' - 0" 3" OH STL FACTORY PT 45 MIN. 13 OH STL PT E8/A-554 A8/A-554 STC 21, MOTORIZED, INSULATED, GASKETED
128B No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 45 MIN. 5 F2 HM PT E2/A-552 A2/A-552 STC 45, INSULATED, GASKETED
128C No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 16 F2 HM PT E2/A-551 A2/A-551 C2/A-551 INSULATED, WEATHERSTRIP
128D No 3' - 0" 7' - 0" 1 3/4" D1 HM PT 45 MIN. 5 F2 HM PT E2/A-552 A2/A-552 STC 45, INSULATED, GASKETED
A
M E
N D
M E
N T
-0
-2
-0
-2
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
1 5
F
L
J
K
G
G.8
H
11'-0" MIN. 11'-0" MIN.
'-0
M
IN
72' - 0"
'-0
M
IN
F5
A-701
A5
A-701
PLENUM DOOR CONNECTION AND
OPERATORS BY BOOTH VENDOR
PLENUM DOORS BY BOOTH VENDOR
STRUCTURAL SUPPORTS BY
BOOTH VENDOR
INSULATED METAL WALL PANELS
BY BOOTH VENDOR
INSULATED METAL PANEL
CEILING, AND LIGHT FIXTURES BY
BOOTH VENDOR ABOVE
LADDER TO CATWALK
BY BOOTH VENDOR
ACCESS DOOR BY
BOOTH VENDOR
FILTER WALL INCLUDING
REQUIRED STRUCTURAL
SYSTEM AND MEDIA BY
BOOTH VENDOR
RECESS. TYP.
COORDINATE QTY AND
SIZES W/ EQUIPMENT
AND ACCESSORIES
RECESS. TYP.
COORDINATE QTY AND
SIZES W/ EQUIPMENT
AND ACCESSORIES
BUILDING STRUCTURE
STRUCTURAL SUPPORTS
BY BOOTH VENDOR AND
ENGINEERED BY BOOTH
VENDOR
18"X18" ARFF HOSE
ACCESS DOORS (TYP
ALL HANGAR DOORS)
FILTER WALL STRUCTURE, BY
BOOTH VENDOR, TO SUPPORT
FUTURE CHARCOAL FILTER
SYSTEM
CATWALK SYSTEM ABOVE
BY BOOTH VENDOR
FALL ARRESTOR RAIL AND
SUPPORTS BY BOOTH VENDOR
INSULATED METAL PANEL
CEILING, AND LIGHT FIXTURES
BY BOOTH VENDOR
C
LE
A
C
LE
A
CLEAR
10' - 0"
CLEAR
46' - 6"
CLEAR
10' - 0"
18"X18" ARFF HOSE
ACCESS DOORS
(TYP ALL DOORS)
FL JK GG.8H G.2
INSULATED METAL PANEL CEILING,
AND LIGHT FIXTURES BY BOOTH
VENDOR
PLENUM DOORS BY BOOTH VENDOR
INSULATED METAL WALL
PANELS AND SUPPORTS BY
BOOTH VENDOR
FILTER WALL AND MEDIA BY
BOOTH VENDOR
B.O. PANEL
17'-0"
B.O. PANEL
27'-0"
F A
LL
P
R O
T E
C T
IO
N
C
LE
A R
W O
R K
IN
G
H E
IG
H
T
T.O. DOOR
30'-0"
A-312
A4
COORD. OPENINGS AND
DOORS FOR FOAM
SYSTEM (TYP)
A7
A-564
PROVIDE CATWALK, COORDINATE TO
ALLOW FOR…
This is the start of the file's text. The full file is on GovTribe.