Attch 22 A 011 EQUIPMENT SCHEDULE METALS TECH and SHOPS.pdf

PDF 105 KB Posted

Attached to
F-22 Low Observable Component Repair Facility (LOCRF) Federal contract opportunity
Solicitation number
W9123621R2023
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This equipment schedule and federal contract opportunity document provide details for a low observable component repair facility project. The project involves construction of a 6,735 square meter facility at Langley Air Force Base in Virginia to provide maintenance capacity for 38 additional F-22A aircraft relocated from Tyndall Air Force Base. The facility will include three low observable critical repair bays, one wash rack bay, shops, administration spaces, and building systems support. Site utilities must support F-22A maintenance requirements. Construction is expected to last 730 calendar days. The facility design must comply with DoD anti-terrorism standards and integrate sustainable practices.

View the file

Other files for this federal contract opportunity

Other files attached to F-22 Low Observable Component Repair Facility (LOCRF), newest first.
File Type Posted
Attachment 8 - Revised Bid Schedule.pdf PDF
W9123621R2023 Amendment 13.pdf PDF
Attch 40 06 61 16 AMENDMENT 09 FEB 22.pdf PDF
Attch 41 Copy of GFE Equipment List_mjm edits 2020.09.24.xlsx XLSX spreadsheet
Attch 38 LOCRF DRAWINGS AMENDMENT 09FEB2022.pdf PDF
Attch 38 08 81 00 Glazing.pdf PDF
Attachment 8 - Revised CLIN Schedule.pdf PDF
Attch 35 32 01 19.61 SEALING OF JOINTS IN RIGID PAVEMENT.pdf PDF
Attch 25 01 11 00 Appendix to 01 11 00 Government Furnished Equipment.pdf PDF
Attch 24 P 601 PLUMBING SCHEDULES.pdf PDF
Attch 23 A 533 ROOF DETAILS.pdf PDF
Attch 37 33 32 16 PACKAGED UTILITY WASTEWATER PUMPING STATION.pdf PDF
Attch 34 13 34 19 METAL BUILDING SYSTEMS.pdf PDF
Attch 28 03 45 00 PRECAST ARCHITECTURAL CONCRETE.pdf PDF
Attch 36 32 13 14.13 CONCRETE PAVING FOR AIRFIELDS AND OTHER HEAVY DUTY PAVEMENTS.pdf PDF
Attch 33 10 56 26.13 MOBILE STORAGE SHELVING UNITS (MECHANICALLY-ASSISTED).pdf PDF
Attch 32 09 97 13.27 HIGH PERFORMANCE COATING FOR STEEL STRUCTURES.pdf PDF
Attch 31 09 90 00 PAINTS AND COATINGS.pdf PDF
Attch 30 08 34 16 CORROSION CONTROL HANGAR DOORS.pdf PDF
Attch 27 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS.pdf PDF
Attch 26 01 14 00 WORK RESTRICTIONS.pdf PDF
W9123621R2023 Amendment 10.pdf PDF
Site Visit 10 January.pdf PDF
W9123621R2023 Amendment 9.pdf PDF
Attachment 19 LOCRF RTA SID PACKAGE.pdf PDF
Attachment 16 LOCRF RTA DWGS PART 2 OF 3.pdf PDF
Attachment 15 LOCRF RTA DWGS PART 1 OF 3.pdf PDF
Attch 13- LOCRF 20Oct21 Blended Drawings Part 3 of 3.pdf PDF
Attch 10- LOCRF 20Oct21 Blended Drawings Part 1 of 3.pdf PDF
Attch 11- LOCRF 20Oct21 Blended Drawings Part 2 of 3.pdf PDF
W9123621R2023 Amendment 8.pdf PDF
W9123621R2023 Amendment 7.pdf PDF
W9123621R2023 Amendment 6.pdf PDF
W9123621R2023 LOCRF Amend 5.pdf PDF
W9123621R2023 Amendment 4.pdf PDF
A.07.24 - Amendment 3.pdf PDF
A.07.24 - Amendment 2.pdf PDF
Attch 12 - LOCRF 100 Specification Part 1 of 1.pdf PDF
Attachment 3 - Past Performance Questionnaire.pdf PDF
Attachment 7 - Small Business Participation Plan.pdf PDF
Solicitation W9123621R2023.pdf PDF
Attch 11 - LOCRF 100 Dwgs Part 2 of 2.pdf PDF
Attachment 2 - Company Specialized Experience.pdf PDF
Attachment 8 - CLIN Schedule.pdf PDF
Attachment 4 - Telephone Interview Questionnaire (For Government Use Only).pdf PDF
Attachment 6 - Small Business Subcontracting Record.pdf PDF
Attch 10 - LOCRF 100 Dwgs Part 1 of 2.pdf PDF
Attachment 1 - Proposal Data Sheet.pdf PDF
Attachment 5 - Letter of Commitment Sample.pdf PDF
Attachment 9 - Langley Environmental Management Special Conditions.pdf PDF
Show all 50

F-22 Low Observable Component Repair Facility (LOCRF) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EQUIPMENT SHEET NOTES

1. THE GOVERNMENT FURNISHED EQUIPMENT GFE LIST IDENTIFIES ITEMS

PROVIDE BY THE GOVERNMENT.

2. GF/GI IDENTIFIES GOVERNMENT FURNISHED/GOVERNMENT INSTALLED

EQUIPMENT. CONTRACTOR TO COORDINATE WITH THE GOVERNMENT TO

MAKE SURE THAT THIS WORK IS PERFORMED WITHOUT INTERFERENCE OF

OTHER WORK. CONTRACTOR TO PROVIDE FOR ANY AND ALL ELECTRICAL

OR MECHANICAL CONNECTIONS NECESSARY FOR OPERATION OF THE

EQUIPMENT AS SCHEDULED. SEE ENGINEERING DRAWINGS FOR FURTHER

INFORMATION.

3. GF/CI IDENTIFIES GOVERNMENT FURNISHED/CONTRACTOR INSTALLED

EQUIPMENT. CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES TO

MAKE SURE THE INSTALLED EQUIPMENT IS FULLY CONNECTED AND

OPERATIONAL. AFTER INSTALLATION EQUIPMENT SHALL BE TESTED TO

MAKE SURE ALL THE NECESSARY CONNECTIONS ARE MADE AND THE

EQUIPMENT IS FULLY OPERATIONAL. CONTRACTOR TO PROVIDE ALL

NECESSARY ELECTRICAL, PLUMBING AND MECHANICAL CONNECTIONS TO

GF EQUIPMENT INCLUSIVE OF LABOR AND MATERIAL NECESSARY FOR A

FULL FUNCTIONAL CONNECTION.

4. GF/CI EQUIPMENT NECESSARY CONNECTIONS SHALL BE VERIFIED BY THE

CONTRACTOR BEFORE ANY WORK AND INSTALLATION TAKES PLACE.

GENERAL SHEET NOTES

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

R H

A M

M E

T T

N A

O F

IL

E

N O

A

W -2

-R

-2

BIM 360://3012011031_F22 LOW OBSERVABLE FACILITY LOCRF/3012011031_LOCRF_A_R19.rvt

1/19/2022 4:10:04 PM

A-011

E Q

U

IP

M E

N T

S C

H E

D U

L E

M

E T

A L

S T

E C

H

S H

O P

S

F Y

F

-2 F

O R

M A

L T

R A

IN

IN

G U

N

IT

F

T U

M

F

E S

T G

E R

R T

O M

E I

S G

R O

E T

H E

-2

-2

L O

W O

B S

E R

V A

B L

E C

O M

P O

S

IT

E R

E P

A

IR

F A

C

IL

IT

Y

L

O C

R F

METALS SHOP EQUIPMENT SCHEDULE

EQUIPMENT NAME EQUIPMENT SIZE FOOTPRINT CLEARANCE REQUIRED POWER REQUIREMENT AMPS HVAC REQUIREMENTS PROCUREMENT & INSTALLATION NOTES

MANUAL HARDINGE METAL LATHE 6'x3'x6' 12'x9' 3 PHASE / 460V 30 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

LARGE CLAUSING MILL 6'x6'x8' 12'x12' 1 PHASE / 460V / AIR SUPPLY 13 HOSE AND REEL (100 PSI) GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

MILLER DYNASTY WELDER #1 2'x4'x6' 13'x8' TABLE/FUME EXTRACTOR INCLUDED 460V / 3 PHASE 88 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A - TABLE/FUME

EXTRACTOR IS GF/CI PHASE B

MILLERMATIC 221 MIG WELDER 2'x4'x6' 5'x7' FUME EXTRACTOR INCLUDED 1 PHASE / 110V / 30A 20 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C (INCLUDING FUME

EXTRACTOR)

ASSORTED CTK'S / CONSUMABLES / LOCKERS / BOXES N/A 30'x50' APPROXIMATE N/A N/A GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

HASS TL2 CNC LATHE 6'x9'x6' 15'x12' 3 PHASE / 220V / AIR SUPPLY 25 HOSE AND REEL (100 PSI) GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

HAAS VF2 CNC MILL 9'x9'x10' 15'x15' 3 PHASE / 240V / AIR SUPPLY 70 HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

HAAS VF4 CNC MILL CUTTER 14'x9'x10' 20'x15' 3 PHASE / 360V-480V / AIR SUPPLY 35 HOSE AND REEL (100 PSI) GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

OMAX WATERJET CUTTER 24'x12'x10' 30'x20' W/FORKLIFT ACCESS 3 PHASE / 480V / WATER DRAINAGE / AIR 6.5 HOSE AND REEL (100 PSI). WATER FAUCET BEHIND MACHINE GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

SMALL CLAUSING MILL 5'x6'x8' 12'x12' 240/480 SINGLE PHASE / AIR SUPPLY 11.7 HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

SMALL CLAUSING LATHE 6'x4'x6' 12'x10' 3 PHASE / 230V 32 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

LARGE CLAUSING LATHE 9'x4'x6' 15'x10' 3 PHASE / 460V 30 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

LARGE VERTICAL BAND SAW 6'x4'x7' 12'x10' 3 PHASE / 460V 5.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

SMALL HORIZONTAL METAL SAW 6'x3'x3' 12'x15' 3 PHASE / 460V 5.4 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

LARGE POWER PRESS 6'x3'x8' 12'x9' 3 PHASE / 460V 15.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

LARGE ARBOR PRESS 1'x2'x6' 4'x4' NONE N/A GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C

DEBURR SHAKER MACHINE 3'x2'x4' 7'x4' 3 PHASE / 230V 8.4 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

STANDUP DRILL PRESS 2'x3'x7' 8'x4' 1 PHASE / 230V 11.5 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

HEAT TREATING OVEN 3'x5'x8' 9'x12' 3 PHASE / 230V 100 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

BELT SANDER / BURR KING 3'x2'x5' 9'x8' 1 PHASE / 110V / 30A 13.4 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C

LARGE GRINDER / WIRE WHEEL 3'x2'x5' 9'x8' 3 PHASE / 220V 3.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

LARGE POWER SHEER 14'x7'x8' 20'x25' 3 PHASE 460V 3.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

LARGE HAND BREAK 10'x2'x4' 16'x12' NONE N/A GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

SMALL FOOT SHEAR 5'x6'x4' 11'x12' NONE N/A GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

S/M TABLE WITH BREAK, ROLLER 6'x12'x5' 12'x18' 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

MILLER DYNASTY WELDER #2 15'x8' TABLE / FUMER INC 10'x8' 1 OR 3 PHASE / 110V 88 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C

LARGE ACCORN WELD TABLE 5'x8'x4' 6'x10' 110V / AIR / REELS N/A GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

METAL IRON WORKER 5'x3'x6' 11'x9' 3 PHASE 460V 6.6 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

BALDOR GRINDER 3'x2'x5' 8'x4' 230V / 3 PHASE 5.9 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

BALDOR BUFFING WHEEL 8'x9' 8'x9' 2 PHASE / 230V 4.8 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

THOMAS CUTTING SAW 2'x2'x5' 7'x7' 230V SINGLE PHASE 11 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

TURRET SHEET METAL PUNCH 2'x3'x6' 8'x9' 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

SNAP-ON SAND BLASTER 4'x3'x6' 10'x9' 110V / AIR 2.2 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

CHOP SAW LARGE YELLOW 5'x4'x5' 11'x10' 230V / SINGLE PHASE 19 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

TABLE/SENSITIVE DRILL PRESS / HARDNESS TESTER 8'x7' 110V 110V 1.2 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

MILLER XMT 450 WELDER 3'x3'x5' 9'x9' 3 PHASE / 460V 67 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

HYPERTHERM PLASMA CUTTER 2'x2'x4' 3'x3' 1 PHASE / 230V 65 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

OXY-ACEYTYLENE RIG 3'x2'x5' 4'x4' 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C

MILLER MINI MIG WELDER 2'x3'x5' 3'x4' 110V / 220V PLUGS 30 GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE C

MACHINE ACCY TOOL BOXES 3'x5' NONE 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

SHEET METAL RACK 12'x21' NONE 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

SOUND STOCK METAL RACK 16'x5' NONE NONE N/A GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

LONG METAL RACK 5'x20' NONE 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

MACHINE SHOP TABLE 5'x8'x4' NONE NONE N/A GF/GI - (GOVERNMENT FURNISHED / GOVERNMENT INSTALLED) - PHASE B

WELD SHOP TIG TABLE 12'x6' NONE 110V / AIR / REELS N/A HOSE AND REEL (100 PSI) GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

MILLER 252 MIG WELDER 4'x3'x6' 11'x10' 230V SINGLE PHASE 42 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

KALAMAZOO BELT SANDER 4'x3'x6' 8'x9' 230V SINGLE PHASE 19 GF/CI - (GOVERNMENT FURNISHED / CONTRACTOR INSTALLED) - PHASE A

LOW OBSERVABLE EQUIPMENT SCHEDULE

ROOM NO. ROOM NAME EQUIPMENT NAME MANUFACTURER / MODEL NO. EQUIPMENT SIZE POWER REQUIREMENTS HVAC REQUIREMENT PLUMBING REQUIREMENT COMMENTS PROCUREMENT & INSTALLATION NOTES

143 DAMAGE REMOVAL / PREP AREA SANDING BOOTH DUSTRON SERIES FILTER 1/DB-24-36-2X15 7'-6" H x 8' L x 24' W 3 PHASE / 460/480V STANDARD (FLA OF 18) 208/230V (FLA GOES TO 36) ALSO

AVAILABLE WITH A SMALL SURCHARGE IF USER REQUIRES. ALSO NEEDED IS 120V

SINGLE PHASE FOR THE BOOTH LIGHTS (WHICH ARE PRE-WIRED)

NONE - SELF CONTAINED,

RECIRCULATING WITH FILTERS

80-110PSI COMPRESSED AIR

SERVICE DROP

GFCI, NEW UNITS. CONTRACTOR TO

PROVIDE FINAL CONNECTION FOR

ELECTRICAL. ERECTED WITHIN THE SPACE.

142 BONDING / LAYUP AREA INDUSTRIAL WALK-IN OVEN BENKO SAHARA INDUSTRIAL OVENS

CUSTOM BUILT TO CLIENT SPECIFICATION

7' H x 16' D x 7' W 3 PHASE / 240 OR 480V STANDARD. ALTERNATE VOLTAGES AVAILABLE NONE NONE ASSUME GOVERNMENT WILL FURNISH

AN ELECTRIC OVEN. NO GAS OR

EXHAUST REQUIRED.

GFCI, NEW UNITS. CONTRACTOR TO

PROVIDE FINAL CONNECTION FOR

ELECTRICAL. SINGLE UNIT, INSTALLED

CONSTRUCTED.

141 PANEL SPRAY ROOM PAINT SPRAY BOOTH SPRAY TECH JUNAIR JA509 5 SERIES

INCLUDING PACKAGED HVAC SYSTEM

SHOWN AS BASIS OF DESIGN ONLY

"13'-7"" H x 24'-5"" L x 19' W

CONFIGURATION OF PACKAGED HVAC

EQUIPMENT TO BE PROVIDED BY THE

GOVERNMENT

TBD - SEE NEEDS LIST. SINGLE POINT OF CONNECTION FOR SPRAY BOOTH /

MAKEUP AIR UNIT / CHILLER / EXHAUST FAN PACKAGE

DEDICATED HVAC SYSTEM

DESIGNED AND SUPPLIED BY THE

SPRAY BOOTH VENDOR

BREATHING AIR SERVICE DROP,

COMPRESSED AIR SERVICE DROP,

NATURAL GAS: 1.5m BTU/HR @

8-14"WC

115-227V; 16.26-7.44FLAMPS (GQT OF 12)

FOR 3-TUBE, HIGH OUTPUT T-5 LIGHT

FIXTURE. 115-277; 7.2-3.6FLAMPS

(QUANTITY OF 8) FOR 4-TUBE LIGHT

FIXTURE

CFCI

117 LAUNDRY / RESPIRATOR ROOM RESPIRATOR WASHER AMERICAN AIRWORKS / GS2400 66" H x 26.5" D x 26" W 400#

5FT CORD. NEMA 5-15P 15A 120VAC / 1 PH / 60HZ / 9A 'CONNECT TO 20A BREAKER' NONE 40-75 PSI HW/CW FLOOR SINK, INDIRECT DRAIN TO SANITARY

GFCI, NEW UNITS. CONTRACTOR TO

PROVIDE FINAL CONNECTION FOR

ELECTRICAL AND PLUMBING. SINGLE UNIT,

INSTALLED CONSTRUCTED.

130 HAZMAT STG./DISPENSARY MOBILE STORAGE N/A 8'-10 1/2" W X 27' - 11 1/4" L NONE NONE NONE MECHANICALLY-ASSISTED WITH

SURFACE MOUNTED TRACKS. REFER TO

SPECIFICATION 10 56 26.13 MOBILE

STORAGE SHELVING

(MECHANICALLY-ASSISTED) FOR

ADDITIONAL INFORMATION.

CFCI

130 HAZMAT STG./DISPENSARY FLAM LOCKERS N/A 3'W X 5'L X 6'H NONE NONE NONE GFGI

130 HAZMAT STG./DISPENSARY CORROSIVE LOCKER N/A 3'W X 5'L X 5'H NONE NONE NONE GFGI

A

M E

N D

M E

N T

-2

-2

-2

-2

FOR INFORMATION ONLY:

THIS NOTE IS RELATED TO THE SMALL PARTS PAINT BOOTH IN ROOM 141. IT IS THE INTENT

OF THE GOVERNMENT TO HAVE THE SMALL PARTS PAINT BOOTH IN ROOM 141 PROVIDED

AND INSTALLED BY THE CONTRACTOR.

Sheets
A-011 - EQUIPMENT SCHEDULE - METALS TECH & SHOPS

File details come from the government source that posted it. Updated .