About this file

This document provides specifications for solid surface fabrications required for the construction of a Low Observable Component Repair Facility at Langley Air Force Base. The project involves building a 6,735 square meter, four-bay facility including three low observable critical repair bays, one wash rack bay, shops, administration areas, and building system support spaces. Solid surface materials are specified for various components including counter tops, vanities, window sills, and shower wall panels. Material requirements include cast acrylic polymer meeting specified physical and chemical standards. Fabrication requirements include seamless joints, polished edges, and attachment of sinks and backsplashes. Installation instructions are provided for loose components, wall panels, sealants, and plumbing interfaces.

View the file

Other files for this federal contract opportunity

Other files attached to F-22 Low Observable Component Repair Facility (LOCRF), newest first.
File Type Posted
Attachment 7- Revised Small Business Participation Plan.pdf PDF
W9123621R2023 Amendment 14.pdf PDF
Attachment 8 - Revised Bid Schedule.pdf PDF
W9123621R2023 Amendment 13.pdf PDF
W9123621R2023 Amendment 12.pdf PDF
Attch 39 08 33 23 AMENDMENT 09 FEB 22.pdf PDF
Attch 40 06 61 16 AMENDMENT 09 FEB 22.pdf PDF
Attch 38 LOCRF DRAWINGS AMENDMENT 09FEB2022.pdf PDF
Attch 38 08 81 00 Glazing.pdf PDF
W9123621R2023 LOCRF Amendment 11.pdf PDF
Attch 21 01FEB2022 AMENDMENT_DRAWINGS.pdf PDF
Attachment 8 - Revised CLIN Schedule.pdf PDF
Attch 35 32 01 19.61 SEALING OF JOINTS IN RIGID PAVEMENT.pdf PDF
Attch 25 01 11 00 Appendix to 01 11 00 Government Furnished Equipment.pdf PDF
Attch 24 P 601 PLUMBING SCHEDULES.pdf PDF
Attch 23 A 533 ROOF DETAILS.pdf PDF
Attch 22 A 011 EQUIPMENT SCHEDULE METALS TECH and SHOPS.pdf PDF
Attch 36 32 13 14.13 CONCRETE PAVING FOR AIRFIELDS AND OTHER HEAVY DUTY PAVEMENTS.pdf PDF
Attch 33 10 56 26.13 MOBILE STORAGE SHELVING UNITS (MECHANICALLY-ASSISTED).pdf PDF
Attch 32 09 97 13.27 HIGH PERFORMANCE COATING FOR STEEL STRUCTURES.pdf PDF
Attch 31 09 90 00 PAINTS AND COATINGS.pdf PDF
Attch 30 08 34 16 CORROSION CONTROL HANGAR DOORS.pdf PDF
Attch 27 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS.pdf PDF
Attch 26 01 14 00 WORK RESTRICTIONS.pdf PDF
W9123621R2023 Amendment 10.pdf PDF
Site Visit 10 January.pdf PDF
Attachment 20 LOCRF RTA Specifications.pdf PDF
Attachment 18 LOCRF RTA FF and E PACKAGE.pdf PDF
Attachment 17 LOCRF RTA DWGS PART 3 OF 3.pdf PDF
Attachment 14 LOCRF RTA AF Sust Scoresheet GP vFeb2017.xlsx XLSX spreadsheet
W9123621R2023 Amendment 9.pdf PDF
Attachment 19 LOCRF RTA SID PACKAGE.pdf PDF
Attachment 16 LOCRF RTA DWGS PART 2 OF 3.pdf PDF
Attch 12- LOCRF 20Oct21 Blended Specifications.pdf PDF
Attch 13- LOCRF 20Oct21 Blended Drawings Part 3 of 3.pdf PDF
Attch 10- LOCRF 20Oct21 Blended Drawings Part 1 of 3.pdf PDF
W9123621R2023 Amendment 8.pdf PDF
W9123621R2023 Amendment 6.pdf PDF
W9123621R2023 LOCRF Amend 5.pdf PDF
A.07.24 - Amendment 1.pdf PDF
Attch 10 - LOCRF 100 Dwgs Part 1 of 2.pdf PDF
Attachment 1 - Proposal Data Sheet.pdf PDF
Attachment 5 - Letter of Commitment Sample.pdf PDF
Attachment 9 - Langley Environmental Management Special Conditions.pdf PDF
Attch 12 - LOCRF 100 Specification Part 1 of 1.pdf PDF
Attachment 3 - Past Performance Questionnaire.pdf PDF
Attachment 7 - Small Business Participation Plan.pdf PDF
Attachment 4 - Telephone Interview Questionnaire (For Government Use Only).pdf PDF
Attachment 6 - Small Business Subcontracting Record.pdf PDF
Solicitation W9123621R2023.pdf PDF
Show all 50

F-22 Low Observable Component Repair Facility (LOCRF) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOW OBSERVABLE COMPOSITE REPAIR FACILITY W91236-21-R-2023

Langley Air Force Base

SECTION 06 61 16

SOLID SURFACING FABRICATIONS

08/10

AMENDMENT 31 JAN 22

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM D570 (1998; E 2010; R 2010) Standard Test Method for Water Absorption of Plastics

ASTM D638 (2014) Standard Test Method for Tensile Properties of Plastics

ASTM D696 (2016) Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30 degrees C and 30 degrees C With a Vitreous Silica Dilatometer

ASTM D2583 (2013a) Indentation Hardness of Rigid Plastics by Means of a Barcol Impressor

ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials

ASTM G21 (2015) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)

CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers

CSA GROUP (CSA)

CSA B45.5-11/IAPMO Z124 (2011; Update 1 2012) Plastic Plumbing Fixtures - First Edition

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates

SECTION 06 61 16 Page 1

NSF INTERNATIONAL (NSF)

NSF/ANSI 51 (2012) Food Equipment Materials

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS SCS Global Services (SCS) Indoor Advantage

TILE COUNCIL OF NORTH AMERICA (TCNA)

TCNA Hdbk (2017) Handbook for Ceramic, Glass, and Stone Tile Installation

UNDERWRITERS LABORATORIES (UL)

UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings

1.2 SYSTEM DESCRIPTION

a. Work under this section includes counter tops, vanities with integral sinks, and window sills and other items utilizing solid polymer (solid surfacing) fabrication as shown on the drawings and as described in this specification. Do not change source of supply for materials after work has started, if the appearance of finished work would be affected.

b. In most instances, installation of solid polymer fabricated components and assemblies will require strong, correctly located structural support provided by other trades. To provide a stable, sound, secure installation, close coordination is required between the solid polymer fabricator/installer and other trades to ensure that necessary structural wall support, cabinet counter top structural support, proper clearances, and other supporting components are provided for the installation of wall panels, countertops, shelving, and all other solid polymer fabrications to the degree and extent recommended by the solid polymer manufacturer.

c. Appropriate staging areas for solid polymer fabrications. Allow variation in component size and location of openings of plus or minus 1/8 inch.

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval.. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.

"G, AE" code is applied where Architect/Engineer review and approval is required. "G, RO" code is applied where Government, Resident Office review and approval is required. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section

01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Detailed Drawings; G , AE

SECTION 06 61 16 Page 2

Installation; G , AE

SD-03 Product Data

Solid Polymer Material

Qualifications

Fabrications

Indoor air quality for solid surface seam and sealant products; S

SD-04 Samples

Material; G , AE

Counter and Vanity Tops ; G , AE

SD-06 Test Reports

Solid Polymer Material

SD-07 Certificates

Fabrications

Qualifications

Indoor Air Quality for solid surface fabrication products; S

SD-10 Operation and Maintenance Data

Clean-up

1.4 CERTIFICATIONS

1.4.1 Indoor Air Quality

Submit required indoor air quality certifications and validations in one submittal package.

1.4.1.1 Indoor Air Quality for Solid Surface Fabricated Products

Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification by other third-party program that products meet the requirements of this Section. Provide current product certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein.

1.4.2 Shop Drawings

Provide detailed drawings of counter tops, vanities with integral and window sills.

SECTION 06 61 16 Page 3

1.5 QUALITY ASSURANCE

1.5.1 Qualifications

To ensure warranty coverage, solid polymer fabricators must be certified to fabricate by the solid polymer material manufacturer being utilized.

Mark all fabrications with the fabricator's certification label affixed in an inconspicuous location. Fabricators must have a minimum of 5 years of experience working with solid polymer materials. Submit solid polymer manufacturer's certification attesting to fabricator qualification approval.

1.6 DELIVERY, STORAGE, AND HANDLING

Do not deliver materials to project site until areas are ready for installation. Deliver components and materials to the site undamaged, in containers clearly marked and labeled with manufacturer's name. Store materials indoors with adequate precautions taken to prevent damage to finished surfaces. Provide protective coverings to prevent physical damage or staining following installation, for duration of project.

1.7 WARRANTY

Provide manufacturer's warranty of ten years against defects in materials, excluding damages caused by physical or chemical abuse or excessive heat.

Provide warranty for material and labor for replacement or repair of defective material for a period of ten years after component installation.

PART 2 PRODUCTS

2.1 MATERIAL

Provide solid polymer material that is a homogeneous filled solid polymer;

not coated, laminated or of a composite construction; meeting CSA B45.5-11/IAPMO Z124 requirements. Provide materials with the minimum physical and performance properties specified. Superficial damage to a depth of 0.01 inch must be repairable by sanding or polishing. Provide amterial thickness as indicated on the drawings. Provide material not less than 1/4 inch in thickness. Submit a minimum 4 by 4 inch sample of each color and pattern for approval. Provide samples that indicate the full range of color and pattern variation. Retain approved samples as the standard for this work throughout the construction duration. Submit test report results from an independent testing laboratory attesting that the submitted solid polymer material meets or exceeds each of the specified performance requirements. Provide materials that meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type).

Provide certification or validation of indoor air quality for solid surface fabrication products.

2.1.1 Cast, 100 Percent Acrylic Polymer Solid Surfacing Material

Provide cast, 100 percent acrylic solid polymer material composed of acrylic polymer, mineral fillers, and pigments and meeting the following minimum performance requirements:

SECTION 06 61 16 Page 4

PROPERTY REQUIREMENT

(min. or max.)

TEST PROCEDURE

Tensile Strength 6800 psi (max.) ASTM D638

Hardness 60-Barcol Impressor (min.) ASTM D2583

Thermal Expansion .000023 in/in/F (max.) ASTM D696

Boiling Water Surface Resistance

No Change ANSI/NEMA LD 3 -3.05

High Temperature Resistance

No Change ANSI/NEMA LD 3 -3.06

Impact Resistance (Ball drop) ANSI/NEMA LD 3 -303

1/4 inch sheet 36 inches, 1/2 lb ball, no failure

1/2 inch sheet 140 inches, 1/2 lb ball, no failure

Mold & Mildew Growth No growth ASTM G21

Bacteria Growth No growth ASTM G21

Liquid Absorption (Weight in 24 hrs.)

0.1 percent max. ASTM D570

Flammability ASTM E84

Flame Spread 25 max.

Smoke Developed 30 max.

Sanitation "Food Contact" approval NSF/ANSI 51

2.1.2 Material Patterns and Colors

See Structural Interior Design (SID) Binder for desired color and patterns. Final Selection and Approval determined by A/E from comparable samples from procured vendor as demonstrated in the SID. Pattern and color must be consistent in appearance, throughout the entire depth (thickness) of the solid polymer material.

2.1.3 Surface Finish

Provide exposed finished surfaces and edges with a uniform appearance.

Exposed surface finish must be matte; gloss rating of 5-20.

2.2 ACCESSORY PRODUCTS

Provide accessory products, as specified below, manufactured by the solid polymer manufacturer or products approved by the solid polymer manufacturer for use with the solid polymer materials being specified.

SECTION 06 61 16 Page 5

2.2.1 Seam Adhesive

Provide a two-part adhesive kit to create permanent, inconspicuous, non-porous, hard seams and joints by chemical bond between solid polymer materials and components to create a monolithic appearance of the fabrication. Adhesive must be approved by the solid polymer manufacturer and color-matched to the surfaces being bonded where solid-colored, solid polymer materials are being bonded together. Provide clear or color matched seam adhesive where particulate patterned, solid polymer materials are being bonded together.

2.2.2 Panel Adhesive

Provide neoprene based panel adhesive meeting TCNA Hdbk, Underwriter's Laboratories (UL) listed. Use this adhesive to bond solid polymer components to adjacent and underlying substrates.

2.2.3 Silicone Sealant

Provide a mildew-resistant, FDA and OSHA Nationally Recognized Testing Laboratory (NRTL) listed silicone sealant or caulk in a clear formulation. The silicone sealant must be approved for use by the solid polymer manufacturer. Use sealant to seal all expansion joints between solid polymer components and all joints between solid polymer components and other adjacent surfaces such as walls, floors, ceiling, and plumbing fixtures.

2.2.4 Seam and Sealant Emissions

Provide seam and other accessory materials that meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type).

Provide validation of indoor air quality for solid surface seam and sealant products.

2.2.5 Conductive Tape

Provide manufacturer's standard conductive foil tape, 4 mils thick, applied around the edges of cut outs containing hot or cold appliances.

2.2.6 Mounting Hardware

Provide mounting hardware, including sink/bowl clips, inserts and fasteners for attachment of undermount sinks and lavatories.

2.3 FABRICATIONS

Provide factory or shop fabricated components to sizes and shapes indicated, to the greatest extent practical, in accordance with approved Shop Drawings and manufacturer's requirements. Provide factory cutouts for sinks, lavatories, and plumbing fixtures where indicated on the drawings. Contours and radii must be routed to template, with edges smooth. Defective and inaccurate work will be rejected. Submit product data indicating product description, fabrication information, and compliance with specified performance requirements for solid polymer, joint adhesive, sealants, and heat reflective tape.

SECTION 06 61 16 Page 6

2.3.1 Joints and Seams

Form joints and seams between solid polymer components using manufacturer's approved seam adhesive. Provide inconspicuous joints in appearance and without voids to create a monolithic appearance.

2.3.2 Edge Finishing

Rout and finish component edges to a smooth, uniform appearance and finish. Provide edge shapes and treatments, including any inserts, as detailed on the drawings. Rout all cutouts, then sand all edges smooth.

Repair or reject defective or inaccurate work.

2.3.3 Counter and Vanity Top Splashes

Fabricate backsplashes and end splashes from 1/2 inch thick solid surfacing material to be 4 inches high in conformance with dimensions and shapes as indicated on the drawings. Provide backsplashes and end splashes for all counter tops and vanity tops locations indicated on the drawings. Where available, provide shop fabricated permanently attached backsplashes.

2.3.3.1 Permanently Attached Backsplash

Fasten permanently attached backsplashes with seam adhesive and to form a radiused coved transition from countertop to backsplash.

2.3.3.2 End Splashes

Provide end splashes as loose for installation at the jobsite after horizontal surfaces to which they are to be attached have been installed.

2.3.4 Window Stools

Fabricate window stools from 1/2 inchthick solid surfacing, solid polymer material, including dimensions, edge shape, and other details selected from manufacturer's available pre-fabricated standards.

2.3.5 Counter and Vanity Tops

Fabricate all solid surfacing, solid polymer counter top and vanity top components from 1/2 inch thick material including details, dimensions, locations, and quantities as indicated on the Drawings. Provide complete counter tops with 4 inch high permanently attached with coved transition backsplash and loose endsplashes at all locations. Attach 2 inch wide reinforcing strip of polymer material under each horizontal counter top seam. Submit a minimum 1 foot wide by 6 inch deep, full size sample for each type of counter top shown on the project drawings. The sample must include the edge profile and backsplash as detailed on the project drawings. Provide solid polymer material of a pattern and color as indicated on the drawings. Provide sample that includes at least one seam and retain approved sample as standard for this work.

2.3.5.1 Counter Top With Sink

a. Stainless Steel or Vitreous China Sink. Provide countertops with sinks that include cutouts to template as furnished by the sink manufacturer. Provide manufacturer's standard sink mounting hardware for stainless steelrimless installation. Seal seam between sink and

SECTION 06 61 16 Page 7 counter top shall be sealed with silicone sealant. Install sink, faucet, and plumbing requirements in accordance with Section 22 00 00

PLUMBING,GENERAL PURPOSE.

2.3.5.2 Vanity Tops With Bowls

a. Provide one-piece vanity top and bowl fabrications that are a standard pre-fabricated product provided by the solid polymer manufacturer.

Each unit must include a vanity top with integral backsplash and sink bowl.

AMENDMENT 31 JAN 22* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

2.3.6 Shower Wal l Panel Syst em

Pr ovi de shower wal l encl osur es i n a syst em of sol i d pol ymer component s t o i ncl ude: panel s, cor ner t r i m, soap di sh, shampoo shel f , panel edge t r i m and shower pan. Pr ovi de di mensi ons of al l component s st andar d manuf act ur er ' s di mensi ons t o be f i el d cut t o f i t . Panel s must be f or med f r om manuf act ur er ' s st andar d 1/ 4 i nch t hi ck sheet pr oduct . Pr ovi de f ul l wi dt h and hei ght panel s wi t h seams occur r i ng onl y at t he i nsi de cor ner s of t he encl osur e. Soap di sh and shampoo shel f must be of a conf i gur at i on, shape, and l ocat i on as st andar d wi t h t he manuf act ur er ' s syst em.

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * AMENDMENT 31 JAN 22

PART 3 EXECUTION

3.1 INSTALLATION

3.1.1 Components

Do not install items that show visual evidence of biological growth.

Install all components and fabricated units plumb, level, and rigid. Make field joints between solid polymer components using solid polymer manufacturer's approved seam adhesives, to provide a monolithic appearance with joints inconspicuous in the finished work. Attach metal or vitreous china sinks and lavatory bowls to counter tops using solid polymer manufacturer's recommended clear silicone sealant and mounting hardware.

Install all solid polymer sinks and bowls using a color-matched seam adhesive. Install all plumbing connections to sinks and lavatories in accordance with Section 22 00 00 PLUMBING, GENERAL PURPOSE.

3.1.1.1 Loose Counter Top Splashes

Mount loose splashes in the locations noted on the drawings. Adhere loose splashes to the counter top with a color matched silicone sealant when the solid polymer components are solid colors. Use a clear silicone sealant to provide adhesion of particulate patterned solid polymer splashes to counter tops.

3.1.1.2 Wall Panels & Panel Systems

Use a neoprene-based panel adhesive for installation of wall panels and system components to substrates. Use seam adhesive to adhere all solid polymer components to each other with the exception of expansion joints and inside corners. Use a silicone sealant to join all inside corners and expansion joints between solid polymer components. Seal all joints between solid polymer components and non-solid polymer surfaces with a

SECTION 06 61 16 Page 8 clear silicone sealant.

3.1.2 Silicone Sealant

Use a clear, silicone sealant or caulk to seal all expansion joints between solid polymer components and all joints between solid polymer components and other adjacent surfaces such as walls, floors, ceiling, and plumbing fixtures. Sealant bead must be smooth and uniform in appearance and use the minimum size necessary to bridge any gaps between the solid surfacing material and the adjacent surface. Install continuous bead that runs the entire length of the joint being sealed.

3.1.3 Plumbing

Make plumbing connections to sinks and lavatories in accordance with Section 22 00 00 PLUMBING, GENERAL PURPOSE.

3.2 CLEAN-UP

Clean all components after installation and cover to protect against damage during completion of the remaining project items. Components damaged after installation by other trades will be repaired or replaced at the General Contractor's cost. Component supplier will provide a repair/replace cost estimate to the General Contractor who must approve estimate before repairs are made. Submit a minimum of six copies of maintenance data indicating manufacturer's care, repair and cleaning instructions. Provide maintenance video if available. Submit maintenance kit for matte finishes.

-- End of Section --

SECTION 06 61 16 Page 9

06 61 16 - SOLID SURFACING FABRICATIONS
PART 1 GENERAL
1.1 REFERENCES
1.2 SYSTEM DESCRIPTION
1.3 SUBMITTALS
1.4 CERTIFICATIONS
1.4.1 Indoor Air Quality
1.4.1.1 Indoor Air Quality for Solid Surface Fabricated Products

1.4.2 Shop Drawings

1.5 QUALITY ASSURANCE
1.5.1 Qualifications
1.6 DELIVERY, STORAGE, AND HANDLING
1.7 WARRANTY
PART 2 PRODUCTS
2.1 MATERIAL
2.1.1 Cast, 100 Percent Acrylic Polymer Solid Surfacing Material
2.1.2 Material Patterns and Colors
2.1.3 Surface Finish
2.2 ACCESSORY PRODUCTS
2.2.1 Seam Adhesive
2.2.2 Panel Adhesive
2.2.3 Silicone Sealant
2.2.4 Seam and Sealant Emissions
2.2.5 Conductive Tape
2.2.6 Mounting Hardware
2.3 FABRICATIONS
2.3.1 Joints and Seams
2.3.2 Edge Finishing
2.3.3 Counter and Vanity Top Splashes
2.3.3.1 Permanently Attached Backsplash
2.3.3.2 End Splashes
2.3.4 Window Stools
2.3.5 Counter and Vanity Tops
2.3.5.1 Counter Top With Sink
2.3.5.2 Vanity Tops With Bowls

2.3.6 Shower Wall Panel System

PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Components
3.1.1.1 Loose Counter Top Splashes
3.1.1.2 Wall Panels & Panel Systems
3.1.2 Silicone Sealant
3.1.3 Plumbing

3.2 CLEAN-UP

File details come from the government source that posted it. Updated .