10_28_13.pdf
PDF 76 KB Posted
- Attached to
- Fort Benning MATOC Federal contract opportunity
- Solicitation number
- W911SF-18-R-0022
About this file
This document contains a solicitation synopsis and related federal contract opportunity. The solicitation synopsis outlines an indefinite delivery/indefinite quantity contract to be awarded by the U.S. Army Mission and Installation Command at Fort Benning, Georgia. The contract period of performance will be one base year and four option years, with a minimum guarantee of $5,000 and a maximum task order value of $5 million. The work will include construction, repair, and related services at Fort Benning and satellite sites. The NAICS code is 236220 and it is set aside 100% for small businesses with a size standard of $36.5 million. The solicitation is scheduled for release on January 28, 2019 with proposals due around February 28, 2019. The point of contact is provided for any questions. The opportunity will be competed under Request for Proposal procedures.
Toilet Accessories
View the file
Other files for this federal contract opportunity
Show all 50
Fort Benning MATOC has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 10 28 13 Page 1
SECTION 10 28 13
TOILET ACCESSORIES
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z535.4 (2011) Product Safety Signs and Labels
ASTM INTERNATIONAL (ASTM)
ASTM C1036 (2016) Standard Specification for Flat Glass
ASTM F2285 (2004; R 2016; E 2016) Standard Consumer
Safety Performance Specification for Diaper Changing Tables for Commercial Use
ASTM G21 (2015) Standard Practice for Determining
Resistance of Synthetic Polymeric Materials to Fungi
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-03 Product Data
Finishes; G
Accessory Items; G
SD-04 Samples
Finishes; G
Accessory Items
SD-07 Certificates
SECTION 10 28 13 Page 2
Accessory Items
1.3 OMITTED
1.4 DELIVERY, STORAGE, AND HANDLING
Wrap toilet accessories for shipment and storage, then deliver to the jobsite in manufacturer's original packaging, and store in a clean, dry area protected from construction damage and vandalism.
1.5 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.
PART 2 PRODUCTS
2.1 MANUFACTURED UNITS
Provide toilet accessories where indicated in accordance with paragraph SCHEDULE. Provide each accessory item complete with the necessary mounting plates of sturdy construction with corrosion resistant surface.
Provide stainless steel products listed herein manufactured from materials containing a minimum of 50 percent recycled content. Provide data identifying percentage of recycled content for stainless steel toilet accessories.
2.1.1 Anchors and Fasteners
Provide anchors and fasteners capable of developing a restraining force commensurate with the strength of the accessory to be mounted and suited for use with the supporting construction. Provide tamperproof design oval heads exposed fasteners with finish to match the accessory.
2.1.2 Finishes
Except where noted otherwise, provide the following finishes on metal:
Metal Finish
Stainless steel No. 4 satin finish
Copper alloy and brass Chromium plated, bright
2.2 ACCESSORY ITEMS
Conform to the requirements for accessory items specified below. Submit fasteners proposed for use for each type of wall construction, mounting, operation, and cleaning instructions and one sample of each other accessory proposed for use. Incorporate approved samples into the finished work, SECTION 10 28 13 Page 3 provided they are identified and their locations noted. Submit certificate for each type of accessory specified, attesting that the items meet the specified requirements.
2.2.1 Mirrors, Glass (MG)
Provide Type I transparent flat type, Class 1-clear glass for mirrors.
Glazing Quality q1 6 mm 1/4 inch thick conforming to ASTM C1036. Coat glass on one surface with silver coating, copper protective coating, and mirror backing paint. Provide highly adhesive pure silver coating of a thickness which provides reflectivity of 83 percent or more of incident light when viewed through 6 mm 1/4 inch thick glass, free of pinholes or other defects. Provide copper protective coating with pure bright reflective copper, homogeneous without sludge, pinholes or other defects, of proper thickness to prevent "adhesion pull" by mirror backing paint.
Provide mirror backing paint with two coats of special scratch and abrasion-resistant paint and baked in uniform thickness to provide a protection for silver and copper coatings which will permit normal cutting and edge fabrication. Mirror shall be framed by stainless steel brackets for anchoring to walls.
2.2.2 Paper Towel Dispenser (PTD)
Provide spring lever type jumbo drum paper towel dispenser constructed of a minimum 0.03 inch Type 304 stainless steel, surface mounted. Furnish tumbler key lock locking mechanism.
2.2.3 Soap Dispenser (SD)
Provide soap dispenser surface mounted, liquid type consisting of a vertical Type 304 stainless steel tank with holding capacity of 1.2 L 40 fluid ounces with a corrosion-resistant all-purpose valve that dispenses liquid soaps, lotions, detergents and antiseptic soaps.
2.2.4 Shelf, Metal, Heavy Duty (SMHD)
Furnish a minimum 18 gauge stainless steel heavy duty metal shelf with hemmed edges. Provide shelves over 750 mm 30 inch with intermediate supports. Provide minimum of 16 gauge supports, welded to the shelf, and spaced no more than 750 mm 30 inch apart.
2.2.5 Toilet Tissue Dispenser (TTD)
Furnish Type II - surface mounted toilet tissue holder with two rolls of standard tissue stacked vertically. Provide stainless steel, satin finish cabinet.
2.2.6 Waste Receptacle (WR)
Provide Type 304 stainless steel waste receptacle, designed for surface mounting. Provide reusable liner, of the type standard with the receptacle manufacturer. Provide a minimum 5 gallon capacity.
2.2.7 Mop and Broom Holder (MH)
Stainless steel with grip jaw cam mechanism securing 4 mop or broom handles. Also includes hooks and storage shelf.
SECTION 10 28 13 Page 4
PART 3 EXECUTION
3.1 INSTALLATION
Do not install items that show visual evidence of biological growth.
Provide the same finish for the surfaces of fastening devices exposed after installation as the attached accessory. Provide oval exposed screw heads.
Install accessories at the location and height indicated. Protect exposed surfaces of accessories with strippable plastic or by other means until the installation is accepted. After acceptance of accessories, remove and dispose of strippable plastic protection. Coordinate accessory manufacturer's mounting details with other trades as their work progresses. Use sealants for brackets, plates, anchoring devices and similar items in showers (a silicone or polysulfide sealant) as they are set to provide a watertight installation. After installation, thoroughly clean exposed surfaces and restore damaged work to its original condition or replace with new work.
3.1.1 Recessed Accessories
Fasten accessories with wood screws to studs, blocking or rough frame in wood construction. Set anchors in mortar in masonry construction. Fasten to metal studs or framing with sheet metal screws in metal construction.
3.1.2 Surface Mounted Accessories
Mount on concealed backplates, unless specified otherwise. Conceal fasteners on accessories without backplates. Install accessories with sheet metal screws or wood screws in lead-lined braided jute, PTFE or neoprene sleeves, or lead expansion shields, or with toggle bolts or other approved fasteners as required by the construction. Install backplates in the same manner, or provide with lugs or anchors set in mortar, as required by the construction. Fasten accessories mounted on gypsum board and plaster walls without solid backing into the metal or wood studs or to solid wood blocking secured between wood studs, or to metal backplates secured to metal studs.
3.2 CLEANING
Clean material in accordance with manufacturer's recommendations. Do not use alkaline or abrasive agents. Take precautions to avoid scratching or marring exposed surfaces.
SECTION 10 28 13 Page 5
3.3 SCHEDULE
Accessories Required
Room or Space MH PTD & WR
(1 EACH)
SMHD SD MG TTD
103 1
115 1
101 1 1 1 1 1
102 1 1 1 1 1
113 1 1 1 1 1
114 1 1 1 1 1
216 1 1 1 1 1
217 1 1 1 1 1
234 1 1 1 1 1
235 1 1 1 1 1