08_14_00_Wood_Doors.pdf
PDF 42 KB Posted
- Attached to
- Fort Benning MATOC Federal contract opportunity
- Solicitation number
- W911SF-18-R-0022
About this file
This solicitation is for an indefinite delivery/indefinite quantity contract to provide construction and repair services at Fort Benning, Georgia. The contract will have a one year base period and four one-year options, with a minimum guarantee of $5,000 and maximum task order of $5 million. Services include construction, repair, maintenance, planning, and reporting for real property facilities. The solicitation will be issued on January 28, 2019 to small businesses, with proposals due February 28, 2019. The contract will be awarded by the Department of the Army Mission and Installation Contracting Command at Fort Leonard Wood.
Wood Doors
View the file
Other files for this federal contract opportunity
Show all 50
Fort Benning MATOC has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RENOVATE BUILDING xxxx, FT. BENNING, GA. xxxxx
SECTION 08 14 00 Page 1
SECTION 08 14 00
WOOD DOORS
PART 1 GENERAL
1.1 REFERENCES
See Scope of Work for additional information.
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
ARCHITECTURAL WOODWORK INSTITUTE (AWI)
AWI Quality Stds. (8th Edition) AWI Quality Standards
ASTM INTERNATIONAL (ASTM)
ASTM E 2074 (2000e1) Standard Test Method for Fire Tests of Door Assemblies, Including Positive Pressure Testing of Side-Hinged and Pivoted Swinging Door Assemblies
ASTM E 283 (2004) Determining the Rate of Air Leakage
Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
ASTM E 90 (2004) Standard Test Method for Laboratory
Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
Laminates
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 252 (2007) Standard Methods of Fire Tests of Door
Assemblies
NFPA 80 (2006; Errata 2008) Standard for Fire Doors and Other Opening Protectives
UNDERWRITERS LABORATORIES (UL)
UL 10B (2008) Fire Tests of Door Assemblies
1.2 SUBMITTALS
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES.
SD-02 Shop Drawings
SECTION 08 14 00 Page 2
Doors; G
Submit drawings or catalog data showing each type of door unit;
descriptive data of head and jamb weatherstripping with installation instructions shall be included]. Drawings and data shall indicate door type and construction, sizes, thickness, methods of assembly door louvers, and glazing.
SD-03 Product Data
Doors; G
Accessories
Water-resistant sealer
Sample warranty
Sound transmission class rating; G
Fire resistance rating; G
SD-06 Test Reports
Split resistance
Cycle-slam
Hinge loading resistance
Submit split resistance test report for doors tested in accordance with WDMA TM-5, cycle-slam test report for doors tested in accordance with WDMA TM-7, and hinge loading resistance test report for doors tested in accordance with WDMA TM-8.
1.3 DELIVERY, STORAGE, AND HANDLING
Deliver doors to the site in an undamaged condition and protect against damage and dampness. Stack doors flat under cover. Support on blocking, a minimum of 100 mm (4 inch) thick, located at each end and at the midpoint of the door. Store doors in a well-ventilated building so that they will not be exposed to excessive moisture, heat, dryness, direct sunlight, or extreme changes of temperature and humidity. Do not store in a building under construction until concrete, masonry work, and plaster are dry. Replace defective or damaged doors with new ones.
1.4 WARRANTY
Warrant doors free of defects as set forth in the door manufacturer's standard door warranty.
PART 2 PRODUCTS
2.1 DOORS
Provide doors of the types, sizes, and designs indicated specified.
SECTION 08 14 00 Page 3
2.1.1 Flush Doors
Provide staved lumber core, Type II flush doors conforming to WDMA I.S. 1-A with faces of sound grade hardwood or hardboard for painted finish grade, natural birch and or plastic laminate. Hardwood veneers shall be rotary cut. Finish plastic laminate faced doors on both vertical edges with laminated plastic of color matching faces.
2.1.2 Acoustical Doors
All latrine doors shall meet this requirement.
WDMA I.S. 1-A, solid core, constructed to provide Sound Transmission Class rating of 35 when tested in accordance with ASTM E 90.
2.1.3 Composite-Type Fire Doors
Provide doors specified or indicated to have a fire resistance rating conforming to the requirements of UL 10B, ASTM E 2074, or NFPA 252 for the class of door indicated. Affix a permanent metal label with raised or incised markings indicating testing agency's name and approved hourly fire rating to hinge edge of each door.
2.2 ACCESSORIES
2.2.1 Door Light Openings
Provide glazed openings with the manufacturer's standard wood moldings.
Provide moldings for doors to receive natural finish of the same wood species and color as the wood face veneers. Provide moldings on the exterior doors with sloped surfaces. Lip type moldings for flush doors.
2.2.2 Additional Hardware Reinforcement
Provide the minimum lock blocks to secure the specified hardware. The measurement of top, bottom, and intermediate rail blocks are a minimum 125 mm 5 inch by full core width. Comply with the manufacturer's labeling requirements for reinforcement blocking, but not mineral material similar to the core.
2.3 FABRICATION
2.3.1 Quality and Construction
Identify the standard on which the construction of the door was based [, identify the standard under which preservative treatment was made,] and identify doors having a Type I glue bond.
SECTION 08 14 00 Page 4
2.3.2 Preservative Treatment
Treat doors scheduled for restrooms, janitor closets and other possible wet locations including exterior doors with a water-repellent preservative treatment and so marketed at the manufacturer's plant in accordance with
WDMA I.S. 4.
2.3.3 Adhesives and Bonds
WDMA I.S. 1-A. Use Type I bond for exterior doors and Type II bond for interior doors. Provide a non-staining adhesive on doors with a natural finish.
2.3.4 Pre-fitting
Provide factory finished and factory pre-fitted doors for the specified hardware, door frame and door-swing indicated. Machine and size doors at the factory by the door manufacturer in accordance with the standards under which the doors are produced and manufactured. The work includes sizing, beveled edges, mortising, and drilling for hardware and providing necessary beaded openings for glass and louvers. Provide the door manufacturer with the necessary hardware samples, and frame and hardware schedules to coordinate the work.
2.3.5 Finishes
2.3.5.1 Field Painting
Factory prime or seal doors, and field paint.
2.3.5.2 Plastic Laminate Finish
All latrine doors shall be plastic laminate finished.
Factory applied, NEMA LD 3, General or Specific purpose type, 1.25 mm (0.050 inch) minimum thickness. Glue laminated plastic for hollow core doors to wood veneer, plywood, or hardboard backing to form door panel. Provide a combined thickness of laminate sheet and backing of 2.5 mm (0.10 inch) minimum.
2.3.5.3 Color
Provide door finish colors as selected by the Contracting Officer from the color selection samples.
2.3.6 Water-Resistant Sealer
Provide manufacturer's standard water-resistant sealer compatible with the specified finishes.
2.4 SOURCE QUALITY CONTROL
Meet or exceed the following minimum performance criteria of stiles of "B" and "C" label fire doors utilizing standard mortise leaf hinges:
SECTION 08 14 00 Page 5
a. Split resistance: Averages of ten test samples not less than 225 kilograms (500 pounds) load when tested in accordance with WDMA
TM-5.
b. Cycle-slam: 200,000 cycles with no loose hinge screws or other visible signs of failure when tested in accordance with the requirements of WDMA TM-7.
c. Hinge loading resistance: Averages of ten test samples not less than 315 kilograms( 700 pounds) load when tested for direct screw withdrawal in accordance with WDMA TM-8 using a No. 12, 30 mm( 1-1/4 inch) long, steel, fully threaded wood screw. Drill 4 mm( 5/32 inch) pilot hole, use 40 mm( 1-1/2 inch) opening around screw for bearing surface, and engage screw full, except for last 3 mm( 1/8 inch). Do not use a steel plate to reinforce screw area.
PART 3 EXECUTION
3.1 INSTALLATION
Before installation, seal top and bottom edges of doors with the approved water-resistant sealer. Seal cuts made on the job immediately after cutting using approved water-resistant sealer. Fit, trim, and hang doors with a 2 mm (1/16 inch) minimum, 3 mm (1/8 inch) maximum clearance at sides and top, and a 5 mm( 3/16 inch) minimum, 6 mm( 1/4 inch) maximum clearance over thresholds. Provide 10 mm (3/8 inch) minimum, 11 mm (7/16 inch) maximum clearance at bottom where no threshold occurs. Bevel edges of doors at the rate of 3 mm in 50 mm (1/8 inch in 2 inch). Door warp shall not exceed 6 mm(1/4 inch) when measured in accordance with WDMA I.S. 1-A.
3.1.1 Fire Doors
Install fire doors in accordance with NFPA 80. Do not paint over labels.
3.2 SCHEDULE
See drawing for door schedule.
-- End of Section --