J-1603000 Natural Gas.pdf

PDF 92 KB Posted

Attached to
Base Operations Support Services For NSA Annapolis and US Naval Academy, Annapolis, Maryland
Solicitation number
N6247026R0017
Issued by

About this file

This document is Section J-1603000 of a federal contract opportunity, containing five attachments that describe the natural gas utility systems at U.S. Naval Academy (USNA) and Naval Station Annapolis (NSAA).

The natural gas distribution systems at both installations are delivered by BG&E (Baltimore Gas & Electric) and enter at multiple isolation points including USNA Gates 1, 2, and 4, Badger Road, Kinkaid Road, Greenbury Point Road, and other designated locations. NSAA operates a medium-pressure system (~10 psi) and a low-pressure system with pipe sizes ranging from 1 to 6 inches in diameter. USNA operates two distinct systems: a medium-pressure system (~10 psi) and a high-pressure system (~97 psi), both serving multiple facilities including base housing, Naval Station facilities, Galley operations, and backup generators. The high-pressure system includes a separate portable boiler connection in the Midshipmen Store parking lot for use when the Central Heating Plant shuts down for maintenance. The contractor shall be responsible for safe and continuous operation of the natural gas delivery systems throughout the installations as designed, including monitoring and regulation of equipment controls, maintaining operating records and logs, and examination, lubrication, and adjustment of equipment and system components such as gauges, meters, piping, valves, pumps, controls, and pressure relief devices. Attachment J-1603000-04 (Natural Gas System Asset Data) and Attachment J-1603000-05 (Natural Gas Utilities Overview Document) are provided as separate documents, with the latter to be provided upon request after contract award.

View the file

Other files

File Type Posted
J-1604000-09 SAMPLE SLUDGE ANAYLSIS REPORT AND SLUDGE GENERATOR REPORT.pdf PDF
J-1503020-06 ASSET DATA AND FREQUENCIES FOR SCHEDULED WORK.xlsx XLSX spreadsheet
J-1502000.1-03 DHA ASSET DATA INDEX, SYSTEM DESCRIPTIONS AND ASSET DATA BY SYSTEM.xlsx XLSX spreadsheet
0100000 C General Information.pdf PDF
J-1605000-07-04 SAMPLE UTILITY CONSUMPTION REPORTING LOG.xlsx XLSX spreadsheet
J-1502000.1 Facility Investment - DHA.pdf PDF
J-1605000-06 SAMPLE NAVFAC BOILER AND UPV INSPECTION FORM AND INSPECTION CERTIFICATE.pdf PDF
J-0200000-07-07 Contractor Incident Report System (CIRS) Form.pdf PDF
J-1604000-14-01 STORMWATER MANAGEMENT REPORT-ANNAPOLIS JANUARY 2017.pdf PDF
J-1602000 Electrical.pdf PDF
J-1604000 Wastewater.pdf PDF
J-0200000 Management and Administration.pdf PDF
J-1607000 Chiller.pdf PDF
1501000 C Facility Management.pdf PDF
0200000 C Management and Administration.pdf PDF
N6247026R0017 Pre-Sol Notice.pdf PDF
J-1606000 Water.pdf PDF
Attachment F - Section F Deliverables.pdf PDF
J-1601000-04 SERVICE DESK GUIDE FOR UTILITY OUTAGES.pdf PDF
J-1605000-07-02 SAMPLE ROVING PATROL LOG.xlsx XLSX spreadsheet
J-1606000-03-02 WTP AND DISTRIBUTION SYSTEM DESCRIPTION 2.docx DOCX document
J-1601000-05 UTILITY INTERRUPTIONS ROAD AND PARKING LOT CLOSURE AUTHORIZATIONS REQUEST FORM.xlsx XLSX spreadsheet
1502000 C Facility Investment.pdf PDF
J-0200000-20 - ELINS.xlsx XLSX spreadsheet
J-1605000-09 HISTORICAL BOILER HRSG UPV TESTING AND CERTIFICATION SCHEDULE.xlsx XLSX spreadsheet
J-1607000-08 Cooling Tower Water Testing and Treatment Asset Data.xlsx XLSX spreadsheet
J-1502000-04 FACILITY DATA.xlsx XLSX spreadsheet
DRAFT Solicitation - N6247026R0017.pdf PDF
J-1604000-14-03 STORMWATER MANAGEMENT REPORT-ANNAPOLIS JANUARY 2017.pdf PDF
J-4 Pre-Award Inquiry Form.xlsx XLSX spreadsheet
J-1503020 Pest Control.pdf PDF
J-1601000-08 EXCAVATION-UTILITY MARKING AUTHORIZATIONS REQUEST FORM.xlsx XLSX spreadsheet
J-1503070-03 Special Event Project Historical Data.xlsx XLSX spreadsheet
1700000 C BSVE.pdf PDF
J-1604000-04 WASTEWATER SYSTEM ASSET DATA.xlsx XLSX spreadsheet
1503020 C Pest Control.pdf PDF
J-1605000-04 STEAM ASSET DATA.xlsx XLSX spreadsheet
1604000 C Wastewater.pdf PDF
1601000 C Utility Management.pdf PDF
J-1604000-15 PERMEABLE PAVEMENT AREAS.pdf PDF
J-0200000-02-02 DBA WAGE DETERMINATION.pdf PDF
J-1700000-05 HISTORICAL FUEL DELIVERY QUANTITIES.xlsx XLSX spreadsheet
1606000 C Water.pdf PDF
J-1503070 Special Events.pdf PDF
J-1502000 Facility Investment.pdf PDF
J-1607000-04 Chiller Plant and Distribution System Asset Data.xlsx XLSX spreadsheet
1605000 C Steam.pdf PDF
J-1503030 Integrated Solid Waste Management.pdf PDF
J-0200000-02-01 SCA WAGE DETERMINATION.pdf PDF
J-1606000-08 MDE SCHEDULE OF MONITORING REQUIREMENTS EXAMPLE.pdf PDF
Show 40 more

Latest 50 of 86 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION J-1603000

NATURAL GAS

ATTACHMENT

NUMBER

ATTACHMENT TITLE

J-1603000-01 DEFINITIONS AND ACRONYMS

J-1603000-02 REFERENCES AND TECHNICAL DOCUMENTS

J-1603000-03 NATURAL GAS SYSTEM DESCRIPTION

J-1603000-04 NATURAL GAS ASSET DATA

J-1603000-05 NATURAL GAS UTILITIES OVERVIEW DOCUMENT

ATTACHMENT J-1603000-01

DEFINITIONS AND ACRONYMS

SEE SEPARATE ATTACHMENT J-0200000-01

ATTACHMENT J-1603000-02

REFERENCES AND TECHNICAL DOCUMENTS

SEE SEPARATE ATTACHMENT J-0200000-03

ATTACHMENT J-1603000-03

NATURAL GAS SYSTEM DESCRIPTION

The natural gas distribution systems commence at the following isolation points:

USNA Gate 4 (North Boundary Road) Badger Road (BG&E Meter House) USNA-306 Pest Control Building (Perry Center) USNA-2 Officer’s Club USNA Gate 2 (South Boundary Road) USNA Gate 1 (South Boundary Road) Kinkaid Road (BG&E Gas Meter House) Greenbury Point Road (Providing service for BSC)

The NSAA natural gas distribution system includes all mechanically and electrically interlocked ancillary parts, equipment, and components required for safe and continuous operation of natural gas delivery throughout the installation as designed. Examples of these parts, equipment, and components include but are not limited to gauges, meters, piping, valves, pumps, controls, pressure relief devices, pressure reducing stations, etc. Safe and continuous operation per design requires tasks such as monitoring and regulation of equipment controls, maintaining operating records, logs, and reports, and examination, and lubrication and adjustment of equipment and system components.

North Severn:

Natural Gas is delivered by BG&E. This System is a medium-pressure system which is ~10psi.

This system enters the Naval Station from a BG&E Gas Meter House before the service begins.

Low-Pressure System:

Currently the low-pressure system supplies gas to several base housing locations and Naval Station Facilities.

The pipe sizes range from 1 inch to 6 inches in diameter.

U.S. Naval Academy:

Natural Gas is delivered by BG&E and enters at different locations. There are two types of Natural Gas Distribution Systems. One is the original medium pressure system which is ~10psi and the second is a high-pressure system which is ~97psi. Both systems enter the U.S. Naval Academy at a BG&E Gas Meter House.

Medium Pressure System:

Currently the medium pressure system supplies gas to several base housing locations and Naval Station Facilities.

The pipe sizes range from 1 inch to 6 inches in diameter. The drawings indicate that there are drop legs in this system.

High Pressure System This system exists throughout the lower portion of the Academy and includes multiple facilities including the Galley operations and the Galley backup generator. Each facility has a meter and regulator. The pipe sizes range from 1 inch to 6 inches in diameter. There is a separate connection for portable boiler hook-up, located in the Midshipmen Store parking lot outside of Bldg. USNA-1013. This is used when the CHP (Central Heating Plant) shuts down as scheduled for high temperature hot water summer repairs, in order to operate the potable boilers on natural gas.

The Natural Gas System Asset Data is provided in J-1603000-04.

A natural gas utilities graphic overview document is also provided upon request as a separate attachment after award. This document is purely supplemental and diagrammatical in nature. It is not necessarily an accurate representation of the current system configuration but may assist in understanding the overall system. Refer to J- 1603000-05 Natural Gas Utilities Overview Document.

ATTACHMENT J-1603000-04

NATURAL GAS SYSTEM ASSET DATA

SEE SEPARATE ATTACHMENT J-1603000-04

ATTACHMENT J-1603000-05

NATURAL GAS UTILITIES OVERVIEW DOCUMENT

J-1603000-05 IS TO BE PROVIDED UPON REQUEST AFTER AWARD