Amendment 0004_Hazmat Report.pdf

PDF 23 MB Posted

Attached to
Construction of P447 Explosive Railcar Yard
Solicitation number
N40085-20-R-0048
Issued by

About this file

This document includes an asbestos survey report and details of a related federal contract opportunity for construction work. The asbestos survey report documents inspection of buildings and areas at Naval Support Activity Crane in Crane, Indiana, and indicates that no asbestos-containing materials or trace asbestos were found in the affected areas. The related federal contract opportunity is solicitation number N40085-20-R-0048 from the Department of the Navy Naval Facilities Engineering Command for construction of an explosive railcar yard and new Defense Logistics Agency disposition site at Crane Army Ammunition Activity in Naval Support Activity Crane. The project scope includes demolition of existing buildings and rail infrastructure at the railcar site, construction of a new rail holding yard, and construction of a new operations building and storage building with associated site work at the Defense Logistics Agency site.

View the file

Other files

File Type Posted
Amendment 0010.pdf PDF
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Amendment 0007_200708 Amendment_Continuation Sheet.pdf PDF
Amendment 0007_200708 Amendment-civil dwgs.pdf PDF
Amendment 0006_Reference drawings B3248_B3249.pdf PDF
Amendment 0006_Reference drawings B2703_B2943.pdf PDF
Amendment 0006_Photo Attachment_Truck Scale Rad Detector.JPG JPG image
Amendment 0006_Photo Attachment Truck Scale RadDetector_Bldg 2943_03.JPG JPG image
Amendment 0006_Photo Attachment Bldg 2703 Internal 03.jpg JPG image
Amendment 0006_Reference drawings B2704.pdf PDF
Amendment 0006.pdf PDF
Amendment 0006_Photo Attachment Truck Scale RadDetector_Bldg 2943_02.JPG JPG image
Amendment 0006_200702 Structural Drawings.pdf PDF
Amendment 0006_Continuation Sheet 2 July 2020.pdf PDF
Amendment 0006_Photo Attachment Bldg 2703 External.jpg JPG image
Amendment 0006_Photo Attachment Bldg 2943 Internal.jpg JPG image
Amendment 0006_ ESS_DRAFT_REPORT.pdf PDF
Amendment 0006_Photo Attachment Bldgs 3248-3249 External.jpg JPG image
Amendment 0006_200630 Civil Drawings.pdf PDF
Amendment 0006_ Photo Attachment_Truck Scale.jpg JPG image
Amendment 0006_Photo Attachment Bldg 2943 External.jpg JPG image
Amendment 0006_Photo Attachment Bldg 2703 Internal 02.jpg JPG image
Amendment 0006_Photo Attachment Truck Scale_RadDetector_Bldg 2943_01.JPG JPG image
Amendment 0006_Photo Attachment Bldg 2703 Internal 01.jpg JPG image
Amendment 0005.pdf PDF
Amendment 0004_Geotechinical Report.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Amendment 0003_Bid Form.pdf PDF
Amendment 0003_200615 Amendment.pdf PDF
Amendment 0002.pdf PDF
Amendment 1.pdf PDF
Attachment G-1596603dwg05of11_E-T-O.pdf PDF
Attachment G-1596603dwg10of11_C.pdf PDF
Attachment G-1596603dwg01of11_G-V-B.pdf PDF
Attachment B - SECNAV_5512_1_11787-One Day Past Request.pdf PDF
Attachment G-1596603spc01of01.pdf PDF
Attachment G- 1596603dwg02of11_C.pdf PDF
Attachment C - Construction Experience Project Data Sheet.docx DOCX document
Attachment G-1596603dwg04of11_S-A-I-F-P-M.pdf PDF
Attachment E - Small Business Subcontracting Plan.docx DOCX document
Attachment G-1596603dwg09of11_C.pdf PDF
Attachment G-1596603dwg07of11_H-D.pdf PDF
Attachment G-1596603dwg08of11_V-B.pdf PDF
Attachment D - Past Performance Questionnaire.docx DOCX document
Attachment G-1596603dwg03of11_C.pdf PDF
Attachment G-1596603dwg11of11_R-E-T.pdf PDF
Attachment F - PPF.docx DOCX document
Show 40 more

Latest 50 of 53 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT NO.

W9Y21001

P447: CAAA Explosive Railcar Holding Yard & DLA Site

6.C – HAZARDOUS MATERIALS SURVEYS AND CERTIFICATIONS

Final Design Submittal

NAVAL FACILITIES ENGINEERING COMMAND (NAVFAC)

Naval Support Activity Crane - Crane, Indiana eProject Number: 1596603

18 December 2019

JACOBS / Ewing Cole A Joint Venture

FOR OFFICIAL USE ONLY

THIS PAGE INTENTIONALLY LEFT BLANK

A. BUILDING 2703

Jacobs/Ewing Cole - A Joint Venture 3 of 280

Building No:

Project Title:

Inspection Date:

WR#(if applicable):

1. Survey Summary

There is no ACM or trace asbestos in the affected areas.

CR-PRX11-ASB-FM-05100-000001 09MAR2017

*ACM = material with >1.0% asbestos content *Trace Asbestos = material with ≤ 1.0% asbestos content

A complete building inspection was performed. Certain objects and components were either inaccessible, could not be fully accessed or were outside of the scope of this survey; see the Additional Details page for clarification.

Additional Details:

Partial Building/Partial Object Inspection:

Complete Object Inspection (denote current location)

Partial Roof Inspection:

ASBESTOS SURVEY CERTIFICATE

NAVAL SUPPORT ACTIVITY CRANE

HM Survey at NSA Crane (Railcar Holding Yard)

9/17/2018 - 9/19/2018 & 9/26/2018

N/A

(Including Roof & Confined Spaces)Complete Building Inspection

Complete Roof Inspection

There is Asbestos Containing Material (ACM) in the affected areas.

There is trace asbestos in the affected areas.

There is assumed ACM in the affected areas based on presumptive evidence (PACM). Bulk sampling will be necessary to rebut the assumption.

There is suspect ACM in the affected areas. Bulk sampling is recommended.

P

Jacobs/Ewing Cole - A Joint Venture 4 of 280

CR-PRX11-ASB-FM-05100-000001 09MAR2017

2. Objectives

3. Sampling Scheme

4. Inaccessible Areas

The objectives of this survey were to identify, assess, and collect bulk samples of suspect ACM and identify presumed asbestos containing materials (PACM) in accordance with the United States Environmental Protection Agency (U.S. EPA) 40 Code of Federal Regulations (CFR), Part 61, Subpart M,(the National Emission Standard for Hazardous Air Pollutant{NESHAP}), the Occupational Safety and Health Administration (OSHA) Asbestos regulations 29 CFR Part 1926.1101, Construction Industry, and the U.S. EPA 40 CFR Part 763, Asbestos Hazard Emergency Response Act (AHERA).

Specified areas within the building and/or object(s) were surveyed for suspect ACM. Each suspect ACM was assigned a Homogeneous Area(HA) number.

Materials with distinctly separate layers (ex. floor tile and associated tile mastic) were each sampled and designated as separate HAs. Materials with an inseparable layering system (ex. drywall, dryall tape, drywall mud system) are sampled as a composite and designated as one HA. Sample locations were chosen to be representative of the suspect ACM present in the surveyed areas. Destructive and/or invasive sampling techniques may have been employed during this inspection. Each sample ID was designated with an HA number, letters representing the HA type [miscellaneous (MISC), surfacing material (SM), or thermal system insulation (TSI)], and the number of samples collected for each HA (i.e. 001, 002, etc). Sample IDs and sample locations were logged onto a sample chain-of-custody form and the samples were submitted to a laboratory for polorized light microscopy (PLM) or transmission electron microscopy (TEM) analysis.

This survey is not the definitive source for the identification of all ACM/PACM located within the building and/or object(s). Often materials are located in confined or inaccessible locations with little or no visible manifestation of their presence. Common examples are pipes or other utilities located behind chases, ceilings, walls, and materials within electrical fixtures. This survey may be used as a first reference but cannot be looked upon as a comprehensive listing of all ACM/PACM present.

Each material disturbed during renovation or demolition activities should be evaluated on a case-by-case basis in order to determine if the suspect material is included in this survey. This is especially relevant for material previously hidden, inaccessible or obscured. If a suspect material is not described in this survey, the material must be assumed to contain asbestos until subsequent sampling and analysis proves otherwise.

Jacobs/Ewing Cole - A Joint Venture 5 of 280

5. Polarized Light Microscopy (PLM) and Transmission Electron Microspy (TEM)

6. The following material(s) contain asbestos:

Samples collected of suspect ACM were transported to a laboratory for analysis by PLM or TEM. Analysis was performed according to the guidelines of the National Voluntary Laboratory Accreditation Program (NVLAP) administered by the National Institute of Standards and Technology (NIST).

The asbestos laboratory is accredited for PLM and TEM analysis by NVLAP.

The U.S. EPA “Method for the Determination of Asbestos in Bulk Building Materials,” Method 600/R-93/116, requires that all, multiple, distinct layers must be analyzed individually. Samples with initial PLM results <10% are point counted in order to determine an exact percentage of asbestos content.

The following material contains asbestos:

HA15 - Cementitious pipe elbow insulation (1.75% Chrysotile and 0.25% Crocidolite)

The following materials are assumed to contain asbestos:

HA7 - Metal fire doors (Assumed ACM) (see HA form for specific door locations that are assumed ACM)

Jacobs/Ewing Cole - A Joint Venture 6 of 280

7. Asbestos Recommendations

8. Non-Asbestos Materials Identified

The following materials do not contain asbestos:

HA1 - Tan flexible caulking;

HA2 - Black flexible caulking;

HA3 - White flexible caulking;

HA4 - Tan cove base mastic;

HA5 - 12"x12" vinyl floor tile, white with gray flecks;

HA6 - Black floor mastic;

HA8 - 12"x12" Mauve vinyl floor tile;

HA9 - Black floor mastic under mauve floor tile;

HA10 - 2'x4' white ceiling tiles, wormholes with gouges and pinholes;

HA11 - 2'x4' white ceiling tiles, wormtracks with gouges and pinholes;

HA12 - 1/2" Drywall composite;

HA13 - 5/8" Drywall composite;

HA14 - Cloth insulation wrap;

HA16 - White PVC roofing membrane;

HA17 - 1/2" white Densdeck sheeting;

HA18 - Black roofing tar and felt (inseparable);

HA19 - Black soft loose fill material in exhaust vent.

Black foam insulation on air conditioning, heating, and water lines is considered non-suspect material and does not contain asbestos. The Overhead Door on the north end of the building is non-suspect. Clear silicone caulking, located in multiple locations, is a non-suspect material. Fiberboard, or duct board, on the indoor furnaces is non-suspect material. White and pink fiberglass insulation, above the ceiling tiles is non-suspect material. The HVAC trunk lines and ductwork above the ceilings is also non-suspect material; some has aluminum covered fiberglass insulation while other duct is “flex-duct” with fiberglass insulation. All pipe insulation, paper and foil wrap over yellow fiberglass insulation, is non-suspect material (note that this is different from HA14 and HA15). The Poly IsoCyanurate (ISO) foam insulation on the roof is also a non-suspect material and does not contain asbestos.

Any work performed on the above mentioned asbestos material must be performed by properly licensed personnel and in accordance with applicable Federal and State regulations and Navy policy.

Jacobs/Ewing Cole - A Joint Venture 7 of 280

Additional Details:

Objects and items inaccessible and/or outside of scope of the inspection:

1. Rheem Air Conditioning unit located on the exterior of the South end of the building. It is not anticipated that this unit would have any asbestos material in the interior of the unit.

2. Carrier Air conditioning unit located on the exterior of the North end of the building. It is not anticipated that this unit would have any asbestos material in the interior of the unit.

3. Carrier gas furnace located in room 001 (North end). It is not anticipated that this unit would have any asbestos material in the interior of the unit.

4. Goodman gas furnace located in room 004. It is not anticipated that this unit would have any asbestos material in the interior of the unit.

5. All electrical panels, interior and exterior, were “live” and inaccessible.

6. All electrical wiring was fully enclosed in conduit and inaccessible.

7. Water heater inside of room 001 was fully enclosed. The subject water heater is fairly new and assumed not to contain asbestos.

8. There is a drywall ceiling above the lower ceiling tiles; the area between the upper drywall ceiling and the bottom of the roof could not be accessed. It is suspected that there is a void between those two layers with some type of insulating material.

9. Not all interior walls could be penetrated to determine the presence of insulation; the conference room walls, however, were observed to have pink fiberglass insulation, which is a non-suspect material.

Jacobs/Ewing Cole - A Joint Venture 8 of 280

Date:

Expiration: 1/8/2020

Phone: 812-863-4401

Email: darren.sipes@cjseto.com

Signature:

Inspector:

Inspector License #: 19A007067

Darren W. Sipes

1/14/2019

SIPES.DARREN.

W.1272863667

Digitally signed by

SIPES.DARREN.W.1272863667

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=CONTRACTOR, cn=SIPES.DARREN.W.1272863667 Date: 2019.01.14 13:32:36 -05'00'

Jacobs/Ewing Cole - A Joint Venture 9 of 280

Building:

Type: Accessible Inaccessible Occupied

Location:

Surfacing TSI

Category I

Nonfriable

LF

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

Description: N/A

Potential for Air Erosion: High Moderate

9/17/2018

Comments:

This material does not contain asbestos; it was recorded as HA1- MISC-001 and HA1-MISC-002 during this inspection. Some of the caulking has been painted over with blue paint.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration:

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 1

Material Description: Tan flexible caulking

Friability of Material:

Around the exterior door frames of the two single entry/exit doors (outside of rooms 001 & 002).

I

Jacobs/Ewing Cole - A Joint Venture 10 of 280

Location:

Surfacing TSI

Category I

Nonfriable

LF

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 2

Material Description: Black flexible caulking

Friability of Material:

Around all window frames around the perimeter of the walls (interior & exterior of windows).

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/17/2018

Comments:

This material does not contain asbestos; it was recorded as HA2- MISC-001 and HA2-MISC-002 during the current inspection. Some of the material has been painted blue.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 11 of 280

Location:

Surfacing TSI

Category I

Nonfriable

LF

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 3

Material Description: White flexible caulking

Friability of Material:

Interior: around all single door frames; around window frames on walls in rooms 003 & 005; in restrooms (006 & 008) around sinks, shower, urinals and toilets.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/17/2018

Comments:

This material does not contain asbestos; it was recorded as HA3- MISC-001 and HA3-MISC-002 during this inspection. Some areas have been painted white and brown.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 12 of 280

Location:

Surfacing TSI

Category I

Nonfriable

LF

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 4

Material Description: Tan cove base mastic

Friability of Material:

Interior on lower walls on back of black cove base.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/17/2018

Comments: This material does not contain asbestos; it was recorded as HA4- MISC-001 and HA4-MISC-002 during this inspection.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 13 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 5

3,172

Material Description: 12"x12" vinyl floor tile, white with gray flecks

Friability of Material:

Interior: rooms 001, conference room, 002, 003, 005, 006, and 008.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

<<1Percent Damage:

Low

Description: Walking surface, foot traffic.

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/17/2018

Comments: This material does not contain asbestos; it was recorded as HA5- MISC-001 and HA5-MISC-002 during this inspection.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 14 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 6

3,172

Material Description: Black floor mastic

Friability of Material:

Floor, under all 12"x12" white vinyl floor tile with gray flecks (HA5).

Located in rooms 001, conference room, 002, 003, 005, 006, and 008.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/17/2018

Comments:

This material does not contain asbestos; it was recorded as HA6- MISC-001 and HA6-MISC-002 during this inspection. Sample HA6- MISC-001 had some gray floor paint adhered to the sample.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 15 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 7

Material Description: Metal fire doors

Friability of Material:

6 doors in the following locations: northeast corner of room 001; door to conference room (in 001); door between room 001 & 002; door to room 005; main entry into room 002; and door to room 004.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/17/2018

Comments: This material is assumed to contain asbestos.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 16 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 8

Material Description: 12"x12" Mauve vinyl floor tile

Friability of Material:

Floor in room 004

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

Tiles are cracked, losing adhesion and minor water damage.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

50Percent Damage:

Low

Description: Walking surface and room contains HVAC unit and IT server.

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/18/2018

Comments:

This material does not contain asbestos; it was recorded as HA8-MISC- 001 and HA8-MISC-002 during this inspection. This HA replaces HA1 from inspections performed in 2011 and 2002.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 17 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 9

Material Description: Black floor mastic under Mauve floor tile

Friability of Material:

Floor of room 004; located under 12"x12" Mauve vinyl floor tile.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

Losing adhesion as some tiles are loose.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

9Percent Damage:

Low

Description: Walking surface.

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/18/2018

Comments:

This material does not contain asbestos; it was recorded as HA9-MISC- 001 and HA9-MISC-002 during this inspection. This HA replaces HA2 dated 11/14/2011.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 18 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

Description: Building is close to Army Demolition Range.

Potential for Air Erosion: High Moderate

9/18/2018

Comments: This material does not contain asbestos; it was recorded as HA10- MISC-001 and HA10-MISC-002 during this inspection.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

Sig. DamageOverall Rating:

<<1Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

Overall good condition, minor wear.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration:

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 10

2,482

Material Description:

2'x4' White ceiling tiles, wormholes with gouges & pinholes

Friability of Material:

Ceiling of rooms 001, conference room, 011, 012, 002, 008, 006, 005 and 003.

I

Jacobs/Ewing Cole - A Joint Venture 19 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 11

Material Description:

2'x4' White ceiling tiles, wormtracks with gouges and pinholes

Friability of Material:

Ceiling in rooms 006 and 008.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

<<1

Very minor water staining.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

<<1Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: Building is close to Army Demolition Range.

Potential for Air Erosion: High Moderate

9/18/2018

Comments: This material does not contain asbestos; it was recorded as HA11- MISC-001 and HA11-MISC-002 during this inspection.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 20 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 12

3,046

Material Description: 1/2" Drywall composite

Friability of Material:

Above ceiling tiles in rooms 001, conference room, 002, 003, 005, 006, 008.

Exposed ceiling in rooms 011, 012, 004 and 006.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/18/2018

Comments:

This material does not contain asbestos; it was recorded as HA12-MISC- 001 and HA12-MISC-002 during this inspection. The material is a composite of drywall, joint compound and tape.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 21 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

Description: N/A

Potential for Air Erosion: High Moderate

9/18/2018

Comments:

This material does not contain asbestos; it was recorded as HA13-MISC- 001 and HA13-MISC-002 during this inspection. The material is a composite of drywall, joint compound and tape.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: Potential for hand and foot contact.

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration:

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 13

3,884

Material Description: 5/8" Drywall composite

Friability of Material:

Interior walls in rooms 001, conference room, 002, 003, 004, 005, 006 and 008.

I

Jacobs/Ewing Cole - A Joint Venture 22 of 280

Location:

Surfacing TSI

Category I

Nonfriable

LF

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 14

Material Description: Cloth insulation wrap

Friability of Material:

Interior: applied over yellow fiberglass insulation on cold water lines along east side of building (primarily above ceiling tiles in room 001, but also present parallel to main entry/exit doors in rooms 001 & 002).

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

<<1

NE end of room 001, at base of pipe, has minor tears and exposed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

<<1Percent Damage:

Low

Description: Two pipe runs are long walls next to entry/exit doors.

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/19/2018

Comments:

This material does not contain asbestos; it was recorded as HA14-TSI- 001, HA14-TSI-002 and HA14-TSI-003 during this inspection. Some of the material has been painted over with white and green paint.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 23 of 280

Location:

Surfacing TSI

Category I

Nonfriable

LF

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 15

Material Description: Cementitious pipe elbow insulation

Friability of Material:

Room 002 southeast corner, above dropped ceiling tiles, on 5 elbows of cold water line.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

<1

No damage observed, other than from sampling.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: Located above main building entrance door.

Potential for Air Erosion: High Moderate

9/19/2018

Comments:

This material contains asbestos (1.75% Chrysotile and 0.25% Crocidolite). It was recorded as HA15-TSI-001 and HA15-TSI-002 during this inspection. The material is located on 5 pipe elbows (approximately 3" diameter and 6" length per elbow) and is covered with cloth insulation wrap (HA14) painted green.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 24 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 16

3,100

Material Description: White PVC Roofing Membrane

Friability of Material:

Roof

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/26/2018

Comments:

This material does not contain asbestos; it was recorded as HA16-MISC- 001 and HA16-MISC-002 during this inspection. Note: the samples had inseparable mastic and ISO felt.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 25 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 17

3,100

Material Description: 1/2" white Densdeck sheeting

Friability of Material:

Roof: under the ISO sheeting (which is under the roofing membrane) on top of wood decking.

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration: Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High

Description: N/A

Potential for Air Erosion: High Moderate

9/26/2018

Comments: This material does not contain asbestos; it was recorded as HA17- MISC-001 and HA17-MISC-002 during this inspection.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

I

Jacobs/Ewing Cole - A Joint Venture 26 of 280

Location:

Surfacing TSI

Category I

Nonfriable

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

Description: N/A

Potential for Air Erosion: High Moderate

9/26/2018

Comments:

This material does not contain asbestos; it was recorded as HA18-MISC-001 and HA18-MISC- 002 during this inspection. The amount of material could not be quantified, as it was only found in one location (out of 3 representative corings); it is suspected that this is debris from the previous roof replacement.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: N/A

Rate Potential for:

Significant

Damage

Sig. DamageOverall Rating:

0Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

No damage observed.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration:

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 18 unknown

Material Description: Black roofing tar & felt (inseparable)

Friability of Material:

Roof - observed only in spot (out of 3 corings) under the Densdeck sheeting, which is on top of the wood decking.

I

Jacobs/Ewing Cole - A Joint Venture 27 of 280

Location:

Surfacing TSI

Category I

Nonfriable

sq. ft.

Condition

Good

Inspector:

CR-PRX11-ASB-FM-05100-000006 15FEB2017

Description: Close proximity to Army Demolition Range

Potential for Air Erosion: High Moderate

9/26/2018

Comments: This material does not contain asbestos; it was recorded as HA19- MISC-001 and HA19-MISC-002 during this inspection.

Date:

Darren W. Sipes Accreditation Number: 19A007067

Minimal / No Damage

Description: Wind can easily move the material.

Rate Potential for:

Significant

Damage

Sig. DamageOverall Rating:

50Percent Damage:

Low

Description: N/A

Frequency of Potential Contact:

Localized

Physical

Description:

Type of Damage: Water

High Moderate

NESHAP Class:

Potential for Disturbance

High Moderate

Damaged

Damage

Low

Low

Unoccupied

Misc.

Category II

Friable

Distributed

Deterioration

The metal vent has holes and the material is spilling onto the roof.

Approximate Amount of Material (linear, square, or cubic feet):

Type of Suspect Material:

Influence of Vibration:

PHYSICAL ASSESSMENT DATA RECORDING FORM

Homogenous Area Number: 2703 19

Material Description: Black soft loose fill material

Friability of Material:

Metal exhaust vent on northern end of roof (material is in between a double-walled vent).

I

Jacobs/Ewing Cole - A Joint Venture 28 of 280

Note: All sampling locations are approximate.

Sampling Locations for Suspect Asbestos Containing Materials (ACM)

Legend

Contains Asbestos or Assumed Asbestos

Does Not Contain Asbestos

Area(s) Inspected

HA1-MISC-001 HA1-MISC-002

HA2-MISC-001

HA2-MISC-002

HA4-MISC-002

HA4-MISC-001

HA5-MISC-001

HA5-MISC-002

HA6-MISC-001

HA6-MISC-002

HA8-MISC-001

HA8-MISC-002

HA9-MISC-001

HA9-MISC-002 HA10-MISC-001

HA11-MISC-001

HA11-MISC-002

HA13-MISC-001

HA13-MISC-002

HA14-TSI-002

HA14-TSI-001 HA7

(Assumed ACM)

See HA for all locations

HA14-TSI-003

HA15-TSI-001

HA15-TSI-002

HA3-MISC-001

HA3-MISC-002 HA10-MISC-002

HA12-MISC-001

Conference Room

HA12-MISC-002

Break area

DRMO

Jacobs/Ewing Cole - A Joint Venture 29 of 280

Sampling Locations for Suspect Asbestos Containing Materials (ACM)

Legend

Contains Asbestos or Assumed Asbestos

Does Not Contain Asbestos

Area(s) Inspected

HA16-MISC-001

HA17-MISC-001

HA16-MISC-002

HA17-MISC-002

HA18-MISC-001

HA18-MISC-002

HA19-MISC-001

HA19-MISC-002

Exploratory sample location for validation

Jacobs/Ewing Cole - A Joint Venture 30 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA1

Does Not Contain Asbestos

HA2

Does Not Contain Asbestos

Jacobs/Ewing Cole - A Joint Venture 31 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA3

Does Not Contain Asbestos

HA4

Does Not Contain Asbestos

Jacobs/Ewing Cole - A Joint Venture 32 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA5

Does ot Contain Asbestos

HA6

Does ot Contain Asbestos

Jacobs/Ewing Cole - A Joint Venture 33 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA7

Assumed to Contain Asbestos

Jacobs/Ewing Cole - A Joint Venture 34 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA8

HA9

Does ot Contain Asbestos

Jacobs/Ewing Cole - A Joint Venture 35 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA10

HA11

Does ot Contain Asbestos

Jacobs/Ewing Cole - A Joint Venture 36 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA12

HA13

Does ot Contain Asbestos

Jacobs/Ewing Cole - A Joint Venture 37 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA14

Jacobs/Ewing Cole - A Joint Venture 38 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA15

Contains Asbestos (1.75% Chrysotile and 0.25% Crocidolite)

Jacobs/Ewing Cole - A Joint Venture 39 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA16

Jacobs/Ewing Cole - A Joint Venture 40 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA17

HA18

Does ot Contain Asbestos

Jacobs/Ewing Cole - A Joint Venture 41 of 280

Asbestos Inspection Photographs B2703, Complete Building Inspection– 17, 18, 19 & 26 Sep. 2018

HA19

Jacobs/Ewing Cole - A Joint Venture 42 of 280

Jacobs/Ewing Cole - A Joint Venture 43 of 280

Jacobs/Ewing Cole - A Joint Venture 44 of 280

Jacobs/Ewing Cole - A Joint Venture 45 of 280

Jacobs/Ewing Cole - A Joint Venture 46 of 280

Jacobs/Ewing Cole - A Joint Venture 47 of 280

OrderID: 161818799

Jacobs/Ewing Cole - A Joint Venture 48 of 280

OrderID: 161818799

Jacobs/Ewing Cole - A Joint Venture 49 of 280

Jacobs/Ewing Cole - A Joint Venture 50 of 280

OrderID: 161819149

Jacobs/Ewing Cole - A Joint Venture 51 of 280

Jacobs/Ewing Cole - A Joint Venture 52 of 280

Jacobs/Ewing Cole - A Joint Venture 53 of 280

BUILDING NO. 2703

OCCUPANTS/VISITORS

1/7/2019

DANGER

ASBESTOS

May Cause Cancer

Causes Damage to Lungs

The following materials in this building contain asbestos or are assumed to contain asbestos:

Room 002, SE Corner, Above Ceiling Tile on Cold

Water Line; Cementitious Pipe Elbow Insulation

(1.75% Chrysotile and 0.25% Crocidolite)

Metal fire doors (Assumed to contain ACM)

DO NOT DISTURB THESE MATERIALS WITHOUT PROPER

TRAINING AND AUTHORIZATION.

Contains Asbestos Fibers

Do not Breathe Dust

Avoid Creating Dust

ANYONE WHO WILL BE CONDUCTING ACTIVITY THAT COULD DISTURB ANY

BUILDING MATERIALS MUST CONTACT THE ASBESTOS PROGRAM MANAGER AT

EXTENSION 3353 PRIOR TO SUCH ACTIVITY.

Jacobs/Ewing Cole - A Joint Venture 54 of 280

Survey Date:

1.

There is no paint in the affected area(s). Nothing was sampled.

There is no LBP in the affected area(s). (See Table Below)

There is LBP in the affected area(s). (See Table Below)

CR-PRX11-LBP-FM-05100-000001 01SEP2016

WR No. (if applicable):

9/13/18, 9/14/18, 9/17/18

N/A

PAINT SURVEY CERTIFICATE

HM Survey at NSA Crane (Railcar Holding Yard)Project Title:

Building No.:

A complete building survey was perfromed at B2703. Certain objects and components were either inaccessible, could not be fully accessed, or were outside of the scope of this survey; see the Additional Details page for clarification.

Partial Building/Partial Object Survey:

Complete Building Survey (Including Roof & Confined Spaces)

Partial Roof Survey

Complete Object Survey (denote current location):

Survey Summary

Additional Details:

Lead Based Paint (LBP) is paint, varnish, shellac, or other surface coatings that contain lead equal to or greater than 5,000 parts per million (ppm), 0.5% by weight, or 1.0 mg/cm2 (40 CFR 745.103). See summary and results below for determinations. Disturbing paint containing any amount of lead may pose a safety risk.

Complete Roof Survey

C

C

P

C

P

T

T

T

Jacobs/Ewing Cole - A Joint Venture 55 of 280

3. Sampling Scheme

4.

This survey is not the definitive source for the identification of all LBP located within the building and/or objects. Often materials are located in confined or inaccessible locations with little or no visible manifestation of their presence. Common examples are pipes or other utilities located behind chases, ceilings, and materials within electrical fixtures. This survey may be used as a first reference but cannot be utilized as a comprehensive listing of all LBP present. Each material disturbed during renovation or demolition activities should be evaluated on a case-by-case basis in order to determine if the suspect material is included in this inspection.

The objectives of this survey were to identify, assess, and collect samples of potential Lead Based Paint (LBP) in accordance with the United States Consumer Product Safety Commission 16 CFR 1303, Environmental Protection Agency (EPA) 40 CFR 745, the Occupational Safety and Health Administration (OSHA) 29 CFR 1910.1025, General Industry Standard, and OSHA 29 CFR 1926.62, Construction Industry Standard.

Building areas and/or objects were surveyed for suspect LBP. Samples collected from similar building and/or object component areas were chosen to be representative of the suspect LBP present in the building and/or object areas. Each sample in this report is identified with a description that reflects the component, substrate, and color sampled.

In some instances, the MSDS/SDS of the paints used on a given surface can be located and reviewed to determine if it contains lead. If no lead is found in the MSDS/SDS, it will be noted on the sample results table along with the paint description and a copy of the MSDS/SDS will be attached to the report. Samples were collected in accordance with the following method:

CR-PRX11-LBP-FM-05100-000001 01SEP2016

Glazed brick/ceramic, porcelain, mirrors and factory applied finished (FAF) metal components, if present and in good condition, may be selectively tested for lead content on a discretionary basis due to difficulty removing a sufficient amount of paint from the surface for laboratory analysis. FAF building/object components in good condition will be listed in this report and will be assumed to contain LBP, but typically will not be sampled. During renovation activities these items are typically removed as whole components and therefore pose less of a lead hazard than other building/object components.

Inaccessible Areas

ASTM E 1729 “Field Collection of Dried Paint Samples for Lead Determination.” Using this method, paint chip samples were submitted to a laboratory for analysis under chain-of-custody (COC) protocol.

Jacobs/Ewing Cole - A Joint Venture 56 of 280

5.

6.

7. Laboratory Results - See attached lab report (if applicable).

Signature: Date:

Inspector:

Phone:

E-mail:

Paint Sample Locations Diagram and/or Photographs - See attached building diagram (s) and/or photos.

Paint chip or dust samples are collected for laboratory analysis by removing one to four square inches of paint from the surface. All layers of paint in the sampled area are included in the sample. Usually samples will contain some of the material beneath the paint, such as wood, plaster, or concrete particles. The amount of this material will be kept to a minimum. Samples collected of suspect LBP are shipped to a lead laboratory for analysis by Flame AAS. The lead laboratory is accredited for Flame AAS analysis by the Environmental Lead Laboratory Accreditation Program (ELLAP). ELLAP is an approved lead laboratory accreditation program under the Environmental Protection Agency (EPA) National Lead Laboratory Accreditation Program (NLLAP). Standard laboratory method EPA SW-846-3050B/7000 is used to quantify lead levels in paint chip sample(s). Sample analysis results are provided for each sample submitted to the laboratory.

If a given material is not described in this survey, the material must be assumed to contain LBP until subsequent sampling and analysis proves otherwise.

Flame Atomic Absorption Spectrophotometry (Flame AAS)

This is especially relevant for materials previously hidden, inaccessible or obscured.

darren.sipes@cjseto.com

812-863-4401

Darren W. Sipes

CR-PRX11-LBP-FM-05100-000001 01SEP2016

1/14/2019

SIPES.DARREN.

W.1272863667

Digitally signed by SIPES.DARREN.W.1272863667 DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=CONTRACTOR, cn=SIPES.DARREN.W.1272863667 Date: 2019.01.14 16:18:02 -05'00'

Jacobs/Ewing Cole - A Joint Venture 57 of 280

Paint Sample Results Summary Table Lead results are in parts per million (ppm).

Sample Description Material Location(s) Deteriorated Lead (ppm)

B2703LBP-1 Blue Paint Exterior: metal siding, window flashing, conduit, electrical panels, concrete window sills;

electrical panels;

No <90

" " Exterior: exhaust vents on north & west walls; No "

" " Exterior: corners of flashing of north overhead door and flashing around single doors. No "

B2703LBP-2

Light gray paint on AC

Unit (FAF) Exterior: Carrier AC unit on north end of building.

No

Assumed lead-based paint

B2703LBP-3 Faded light green paint on AC Unit (FAF)

Exterior: Rheem AC unit on south end of building.

No Assumed lead-based paint

B2703LBP-4

Brown exterior metal paint(FAF) Exterior: all guttering, downspouts and fascia (along roofline).

No

Assumed lead-based paint

B2703LBP-5 Brown paint on exhaust vent

Exterior: on exhaust vent on top of roof (north end) Yes 3,200

B2703LBP-6 Yellow over yellow paint Exterior: iron beam on south end of the building;

two metal posts on east side of building; Yes 83,000

" " and, on the southeast concrete walkway/entry support to the main entrance. " "

B2703LBP-7

Yellow over yellow over red paint Exterior: on northeast concrete walkway support (side of metal).

Yes 84,000

B2703LBP-8

Blue over brown over red paint Exterior: on north overhead door frame. Yes 52,000

B2703LBP-9 Black window paint (FAF) All windows around the perimeter of the building.

No

Assumed lead-based paint

B2703LBP-10 Brown door paint All metal doors, frames and overhead rollup door (exludes doors in rooms 011 & 012) No <97

CR-PRX11-LBP-FM-05100-000001 01SEP2016

No Paint to Sample

Lead-Based Paint (Bold) = ≥ 5,000 ppm, 0.5% by weight or 1.0 mg/cm2.

Jacobs/Ewing Cole - A Joint Venture 58 of 280

Sample Description Material Location(s) Deteriorated Lead (ppm)

B2703LBP-10 Brown door paint Interior window frames in rooms 003 & 005 No <97

B2703LBP-11 Brown over green over yellow paint Doors & frames in rooms 011 & 012 No 2,800

B2703LBP-12

Pewter paint on furnace

(FAF)

Interior: on Carrier Furnace in room 001 No

Assumed lead-based paint

B2703LBP-13

White over yellow over red paint Interior: steel support columns in room 001. No 57,000

B2703LBP-14 White wall paint Interior: on drywall and concrete walls in rooms 001, conference room, 002, 003, 005, 006, 008, 011, 012;

No <90

" " on drywall wall & ceiling in room 004 & drywall ceiling in shower room of 006. " "

B2703LBP-15 Beige paint Interior: metal stall walls & stall doors in room 006. No <160

B2703LBP-16 Tan painted metal (FAF) Exterior: under blue paint on all metal wall siding, exterior flashing around north overhead door; and, No Assumed lead-based paint

" " exterior window flashing and exterior single door flashing. " "

B2703LBP-17 Yellow paint on gas line Interior: on gas line in room 004. No 480

B2703LBP-18 White over teal paint Interior: block/conrete walls and conduit in room 004. No 1,600

B2703LBP-19

Dark gray paint on furnace (FAF) Interior: on Goodman gas furnace in room

004.

No

Assumed lead-based paint

B2703LBP-20 Gray floor paint Interior: under floor tiles and black mastic in rooms 001 & 004 No 1,100

Lead-Based Paint (Bold) = ≥ 5,000 ppm, 0.5% by weight or 1.0 mg/cm2.

CR-PRX11-LBP-FM-05100-000001 01SEP2016

No Paint to Sample

Jacobs/Ewing Cole - A Joint Venture 59 of 280

Sample Description Material Location(s) Deteriorated Lead (ppm)

B2703LBP-21 Red floor paint Interior: under floor tiles under black mastic in rooms 002 & 004 No 2,700

CR-PRX11-LBP-FM-05100-000001 01SEP2016

No Paint to Sample

Lead-Based Paint (Bold) = ≥ 5,000 ppm, 0.5% by weight or 1.0 mg/cm2.

Jacobs/Ewing Cole - A Joint Venture 60 of 280

Objects and items inaccessible and/or outside of the scope of the survey:

1. A yellow propane tank, located on the exterior to the north of the building, is not included in the scope of this survey. The subject tank provides propane to the building for heating purposes.

2. Electrical panels located on the interior of the building were in service and in good condition (paint is a factory applied finish);

per Crane's Lead Program Manager there is no need to sample these panels for Lead. There were 3 gray panels and 1 red fuse box observed.

3. The drywall ceiling located above the suspended ceiling tiles was unpainted drywall. Between the drywall ceiling and bottom of the roof is a void that could not be accessed.

Additional Details:

CR-PRX11-LBP-FM-05100-000001 01SEP2016

Jacobs/Ewing Cole - A Joint Venture 61 of 280

Paint Sampling Locations

Legend Contains Lead-Based Paint (sample > 5000 ppm) or Assumed LBP

Does Not Contain Lead-Based Paint (sample <5,000 ppm)

Area(s) Surveyed

B2703LBP-1 B2703LBP-17

B2703LBP-18

B2703LBP-15

B2703LBP-3

(FAF not sampled)

B2703LBP-21 B2703LBP-7

B2703LBP-10

B2703LBP-13

B2703LBP-11

B2703LBP-14 B2703LBP-20

B2703LBP-2

(FAF not sampled)

B2703LBP-8

B2703LBP-12

(FAF not sampled)

B2703LBP-6

B2703LBP-9

(FAF not sampled)

Conference Room

B2703LBP-19

(FAF not sampled)

B2703LBP-4

(FAF not sampled)

B2703LBP-16 (FAF not sampled) (under LBP-1)

Jacobs/Ewing Cole - A Joint Venture 62 of 280

Paint Sampling Locations

Legend Contains Lead-Based Paint (sample > 5000 ppm) or Assumed LBP

Does Not Contain Lead-Based Paint (sample <5,000 ppm)

Area(s) Surveyed

B2703LBP-5

Jacobs/Ewing Cole - A Joint Venture 63 of 280

Paint Survey Photographs B2703, Complete Building Survey – 9/13, 9/14 & 9/17/2018

B2703LBP-1

Does Not Contain Lead-based Paint

B2703LBP-2

Assumed to Contain Lead-based Paint (FAF)

Jacobs/Ewing Cole - A Joint Venture 64 of 280

B2703LBP-3

Assumed to Contain Lead-based Paint (FAF)

B2703LBP-4

Assumed to Contain Lead-based Paint (FAF)

Jacobs/Ewing Cole - A Joint Venture 65 of 280

B2703LBP-5

B2703LBP-6

Contains Lead-based Paint

Jacobs/Ewing Cole - A Joint Venture 66 of 280

B2703LBP-7

Contains Lead-based Paint

Jacobs/Ewing Cole - A Joint Venture 67 of 280

B2703LBP-8

B2703LBP-9

Assumed to Contain Lead-based Paint (FAF)

Jacobs/Ewing Cole - A Joint Venture 68 of 280

B2703LBP-10

B2703LBP-11

Does Not Contain Lead-based Paint

Jacobs/Ewing Cole - A Joint Venture 69 of 280

B2703LBP-12 (FAF)

Assumed to Contain Lead-based Paint (FAF)

B2703LBP-13

Contains Lead-based Paint

Jacobs/Ewing Cole - A Joint Venture 70 of 280

B2703LBP-14

B2703LBP-15

Does Not Contain Lead-based Paint

Jacobs/Ewing Cole - A Joint Venture 71 of 280

B2703LBP-17

B2703LBP-16

Assumed to Contain Lead-based Paint (FAF)

Jacobs/Ewing Cole - A Joint Venture 72 of 280

B2703LBP-18

B2703LBP-19

Assumed to Contain Lead-based Paint (FAF)

Jacobs/Ewing Cole - A Joint Venture 73 of 280

B2703LBP-20

B2703LBP-21

Does Not Contain Lead-based Paint

Jacobs/Ewing Cole - A Joint Venture 74 of 280

ConcentrationAnalyzed Weight RDL LeadClient SampleDescription Collected

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

6340 CastlePlace Dr., Indianapolis, IN 46250 Phone/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com indianapolislab@emsl.com

Attn: Darren Sipes CJ Seto Support Services LLC 13980 E. CAPT WJ Nelson Dr Bloomfield, IN 47424

Received: 09/25/18 9:55 AM

B2703.LBP.RailcarYard.EMCN028

Fax:

Phone: (812) 863-4401

Project:

9/14/2018Collected:

161818883 CustomerID: 32CJSS78A CustomerPO:

ProjectID:

EMSL Order:

Site: BLUE PAINT <90 ppm9/28/2018 0.2234 g

161818883-0001 909/13/2018B2703LBP - 1 ppm

Site: BROWN PAINT ON EXHAUST VENT 3200 ppm9/28/2018 0.2291 g

161818883-0002 879/13/2018B2703LBP - 5 ppm

Site: YELLOW OVER YELLOW PAINT 83000 ppm9/28/2018 0.2247 g

161818883-0003 22009/13/2018B2703LBP - 6 ppm

Site: YELLOW OVER YELLOW OVER RED PAINT 84000 ppm9/28/2018 0.226 g

161818883-0004 22009/13/2018B2703LBP - 7 ppm

Site: BLUE OVER BROWN OVER RED 52000 ppm9/28/2018 0.2216 g

161818883-0005 23009/13/2018B2703LBP - 8 ppm

Site: BROWN DOOR PAINT <97 ppm9/28/2018 0.2067 g

161818883-0006 979/14/2018B2703LBP - 10 ppm

Site: BROWN OVER GREEN OVER YELLOW PAINT 2800 ppm9/28/2018 0.2269 g

161818883-0007 889/14/2018B2703LBP - 11 ppm

Site: WHITE OVER YELLOW OVER RED PAINT 57000 ppm9/28/2018 0.2345 g

161818883-0008 21009/14/2018B2703LBP -…