0155_A_TANK VENT INSPECTION (5YR).docx

DOCX document 49 KB Posted

Attached to
USNS ARCTIC REGULAR OVERHAUL DRY DOCKING 2022 Federal contract opportunity
Solicitation number
N3220521R4207
Issued by
Department of the Navy Military Sealift Command

About this file

This document outlines requirements for a federal contract to refurbish air escape terminals, check valves, and inverted vent check valves associated with various tanks aboard the USNS Arctic. The contractor will be required to inspect all tank vents and submit condition reports, temporarily install blanks on vent pipes, refurbish valves and screens, clear obstructions from vent piping, repaint surfaces, and submit final condition reports. The enclosure lists the specific tank vent locations, types, materials and sizes. The related opportunity is a pre-solicitation notice for the USNS Arctic's regular overhaul and dry docking scheduled for January 2022, to be awarded by the Department of the Navy Military Sealift Command.

View the file

Other files for this federal contract opportunity

Other files attached to USNS ARCTIC REGULAR OVERHAUL DRY DOCKING 2022, newest first.
File Type Posted
Copy of J - 3 Category B Items ARCTIC REV 1.xlsx XLSX spreadsheet
S9555-AR-MMO-010_10_0.pdf PDF
USNS Arctic Master Calibration List.xlsx XLSX spreadsheet
S6161-PQ-FSE-010_3_0.pdf PDF
Machinery Control SystemSSDGLM2500 Sensors.docx DOCX document
AOE-8 List of Waster Sleeves.xls XLS spreadsheet
Q and A 2.docx DOCX document
J - 2 Category A Items ARCTIC REV 1.xlsx XLSX spreadsheet
0656_A_LIFE RAFT CERTIFICATION_REV-A-ARCTIC TAOE CCSI.docx DOCX document
0956_A_OVERHAULING SEA VALVES (5YR)_TAOE_CCSI.docx DOCX document
0955_A_STERN TUBE SEAL ASSEMBLY (5YR)(SCSI)_TAOE_CCSI.docx DOCX document
0953_A_ANCHORS CHAINS AND LOCKERS 5YR_TAOE_CCSI.docx DOCX document
0966_A_SHAFT ALIGNMENT AND BEARING REACTION CHECKS_TAOE_CSI.docx DOCX document
0967_A_SHAFT ALIGNMENT AND BEARING REACTION CHECKS 3 AND 4_TAOE_CSI.docx DOCX document
0962_A_CATHODIC PROTECTION (5YR)_TAOE_CCSI_REV 1.docx DOCX document
0968_A_SHAFT ALIGNMENT AND BEARING REACTION CHECKS (POST SEA TRIAL)_TAOE_CCSI.docx DOCX document
0959_A_UNDERWATER HULL CLEANING AND PAINTING-NWB(10YR)_TAOE_CCSI_REV 1.docx DOCX document
Q and A 1.docx DOCX document
0957_A_PROPELLER CLEAN AND POLISH_ON DOCK (2.5YR)_TAOE_CCSI.docx DOCX document
J - 3 Category B Items ARCTIC REV 1.xlsx XLSX spreadsheet
Arctic 2022 ROH Index REV 1.docx DOCX document
0963_A_SEA CHEST AND MARINE GROWTH PROTECTION (5YR)_TAOE_CCSI.docx DOCX document
0961_FREEBOARD PRESERVATION (5 YR)_TAOE_CCSI.docx DOCX document
WI 0405 REFERENCE TV-DTS SYSTEM PERFORMANCE SPECIFICATION TEST SHEET.docx DOCX document
J - 8 Request for Spec Clarification.doc DOC document
J - 12 Past Performance Data.doc DOC document
J - 14 Technical Data Non-Disclosure.docx DOCX document
J - 10 Interport Differential - Arctic Nov MTA 2018.docx DOCX document
J - 11 Dry Dock Evaluation Form.docx DOCX document
J - 9 Disclosure of Lobbying Activities SF-LLL.doc DOC document
J - 7 MSC Ship Repair Facility Survey.doc DOC document
J - 4 GFM LIST USNS ARCTIC FY 22 ROHDD.xlsx XLSX spreadsheet
J - 13 PAST PERFORMANCE QUESTIONNAIRE.docx DOCX document
J - 2 Category A Items ARCTIC.xls XLS spreadsheet
J - 3 Category B Items ARCTIC.xls XLS spreadsheet
N3220521R4207 ARCTIC Solicitation.docx DOCX document
SYNOPSIS N3220521R4207 USNS ARCTIC ROH 2022.docx DOCX document
SOURCES SOUGHT FOR USNS ARCTIC ROHDD 2022.docx DOCX document
Show all 38

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABSTRACT

This work item describes the requirement to refurbish air escape screened terminals, swing check valves for tank overflows, and inverted vent check valves associated with various tanks.

REFERENCES/ENCLOSURES

References MSC Drawing No. 506-6360553, Tank Vent Drawing Enclosure Tank Vent List

ITEM LOCATION/DESCRIPTION

Location/Quantity Locations: Various

1.1.1 Quantity: See Enclosure 2.2.1

Item Description/Manufacturer’s Data: None additional GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICE: None

NOTES

The contractor and all subcontractors, regardless of tier must consult the General Technical Requirements (GTR) to determine applicability to this work item. In performance of this work item, the contractor and all subcontractors regardless of tier must comply with the requirements of all applicable GTR’s including but not limited to GTR’s 1 through 7, 22, 23, 24, 28, and 29.

The contractor and all subcontractors regardless of tier are advised to review other work items under this contract, including but not limited to Work Items 002, 004, 013, 020, 021.to determine their effect on the work required under this work item. Many of the definitions relating to performance of this work item are found in Work Item 001.

QUALITY ASSURANCE REQUIREMENTS: None additional

STATEMENT OF WORK REQUIRED

1.2 Refurbish air escape screened terminals, overflow swing check valves, and inverted vent check valves associated with all tanks using References 2.1.1 and Enclosure 2.2.1 as guidance.

Accomplish a survey of tank vents identified in Enclosure 2.2.1. Submit an “as found” condition report that includes all vent locations, types, material, and sizes. Base inspections and repairs on tank vents being 6” diameter gooseneck vents where not specified in Enclosure 2.2.1.

1.2.1 Temporarily install blanks on all open vent pipes.

Lap all guides, stems, and seats.

Check discs for good contact with respective seats.

Replace flame screens with new 316 stainless steel mesh flame screens.

Prior to re-assembly, present the valves and screened terminals to the ABS Surveyor and OMT REP for inspection.

Prior to re-installation, demonstrate correct operation of the valves to the ABS Surveyor and OMT REP.

Clear obstructions and debris from tank vent piping for each tank associated with a valve or screened terminal using Reference 2.1.1 and Enclosure 2.2.1 as guidance.

1.3 After re-installation, present the valves and screened terminals to the ABS Surveyor and OMT REP for inspection.

1.4 Painting

Prepare, prime, paint and restore all new, soiled, and disturbed surfaces to match surrounding surfaces.

1.5 Reports

1.5.1 When inspection, service and testing reveal any deficiency a condition report is to be submitted to the OMT REP with recommended repairs and parts required. Submit one (1) electronic copy in Portable Document Format (PDF).

Provide an “as released” condition report to the OMT REP that includes a complete Enclosure 2.2.1 and a summary of all vent inspection and repairs. Submit one (1) electronic copy in Portable Document Format (PDF).

1.6 Manufacturer’s Representative: None

1.7 Preparation of Drawings: None additional

GENERAL REQUIREMENTS: None additional

USNS ARCTIC

(T-AOE 8)

HULL STRUCTUREN32205-21-R-420717 February 2021
ITEM NO. 155Category "A"MSC/N756/CSI

TANK VENT INSPECTION (ABS)

155-10

ENCLOSURE 2.2.1 – TANK VENT LIST

COMPARTMENT
LOCATION (FRAMES)
TYPE
VENT LOCATION
MATERIAL
SIZE (IN)

SHIP'S FUEL OIL TANKS

5-580-1-F
580-605
5-580-2-F
580-605
4-605-1-F
605-625
4-605-2-F
605-625
6-605-0-F
605-625
4-625-1-F
625-685
4-625-2-F
625-685
6-625-0-F
625-685
3-685-1-F
685-730
3-685-2-F
685-730
4-685-0-F
685-730
2-141-1-F
141-150
2-141-2-F
141-150
2-435-1-F
435-445
2-435-2-F
435-445
7-445-1-F
445-455
7-445-2-F
445-455

SHIP'S FUEL OIL TANKS

3-565-1-F
565-580
3-565-4-F
565-580
5-565-1-F
565-580
5-565-2-F
565-580

CONTAMINATED FUEL TANKS

3-445-3-F
445-455
7-430-0-FF
430-445
GOOSENECK
01-397-1

CARGO FUEL TANKS

7-65-0-FF
65-105
7-245-0-FF
245-265
GOOSENECK
01-255-2
7-395-1-FF
395-425(S)
7-395-2-FF
395-425(P)
GOOSENECK
01-407-2
7-425-1-FF
425-455(S)
7-425-2-FF
425-455(S)
GOOSENECK
01-421-2
7-565-0-FF
565-605(C)
GOOSENECK
01-564-2

CONVERTIBLE CARGO TANKS

7-150-0-FF/JJ
150-205

CONVERTIBLE CARGO TANKS

7-265-0-FF/JJ
265-330
GOOSENECK
01-265-1
7-330-0-FF/JJ
330-395
7-330-1-FF/JJ
330-362 (S)
7-330-2-FF/JJ
330-362 (P)

JP-5 TANKS

7-045-0-JJ
45-65
7-105-0-JJ
105-150
GOOSENECK
01-105-1
7-205-1-JJ
205-265(S)
7-205-2-JJ
205-265(P)
7-265-1-JJ
265-297 (S)
GOOSENECK
01-280-1
7-265-2-JJ
265-297 (P)
GOOSENECK
01-275-2
7-297-1-JJ
297-330 (S)
GOOSENECK
01-318-1
7-297-2-JJ
297-330 (P)
7-362-1-JJ
362-395 (S)
GOOSENECK
01-368-1
7-362-2-JJ
362-395 (P)

CONTAMINATED JP-5 TANKS

7-205-0-JJ
205-210
GOOSENECK
01-260-1

CONTAMINATED JP-5 TANKS

3-445-2-J
445-455
3-445-4-J
445-455

LUBE OIL TANKS

2-114-2-F
114-123
3-502-1-F
502-510(S)
3-502-3-F
502-510 (S)
3-502-5-F
502-510 (S)
3-502-7-F
502-510 (S)
3-502-9-F
502-510 (S)
3-502-11-F
502-510 (S)
3-510-2-F
510-518 (P)
3-510-4-F
510-518 (P)
3-510-6-F
510-518 (P)
3-510-8-F
510-518 (P)
3-510-10-F
510-518 (P)
3-510-12-F
510-518 (P)
4-502-1-F
502-510 (S)
4-502-3-F
502-510 (S)
4-502-5-F
502-510 (S)
4-502-7-F
502-510 (S)
4-502-9-F
502-510 (S)

LUBE OIL TANKS

4-502-11-F
502-510 (S)
4-502-13-F
502-510 (S)
4-510-2-F
510-518 (P)
4-510-4-F
510-518 (P)
4-510-6-F
510-518 (P)
4-510-8-F
510-518 (P)

LUBE OIL TANKS

4-510-10-F
510-518 (P)
4-510-12-F
510-518 (P)
4-510-14-F
510-518 (P)

OILY WASTE TANKS

7-488-0-F
488-499
7-499-0-F
499-510
7-483-1-F
483-488
7-483-2-F
483-488

POTABLE WATER TANKS

7-477-2-W
477-488 (P)
7-488-1-W
488-499 (S)
7-488-2-W
488-499 (P)
7-499-1-W
499-510 (S)

RESERVE FEED WATER TANKS

4-477-2-W
477-488 (P)
4-510-1-W
510-521 (S)

SALT WATER BALLAST TANKS

7-016-0-W
15-35

SEWAGE HOLDING TANKS

3-161-1-CHT
161-184
3-605-0-CHT
605-630

MISCELLANEOUS TANKS

WASTE WATER COLLECTING TANK
477-488 (C)
WASTE WATER COLLECTING TANK
538-543 (P)
SSDG COLLECTING TANK
483-488 (S)

MISCELLANEOUS TANKS

GAS TURBINE WASTE COLLECTING TANK
483-488 (P)
GAS TURBINE WASTE COLLECTING TANK
527-532 (S)
OILY WASTE COLLECTING TANK
521-527 (S)
USED OIL TANK
132-141 (P)
USED OIL COLLECTING TANK
532-538 (P)
CHAIN LOCKER SUMP
35-45 (C)
LO SUMP MMR 1
460-482
LO SUMP MMR 2
526-549
OILY WASTE DRAIN COLLECTING TANK/ CARGO JP-5 ROOM
221-225
OILY WASTE DRAIN COLLECTING TANK/ CARGO OIL ROOM
417-420
EMERGENCY GAS TURBINE FUEL TANK MMR1
496-499

MISCELLANEOUS TANKS

EMERGENCY GAS TURBINE FUEL TANK MMR2
518-521

File details come from the government source that posted it. Updated .