About this file

This is a structured cabling design drawing for Swartz Creek Middle School Unit B, created by Convergent Technology Partners. The drawing details the installation requirements for Category 6A UTP cabling throughout multiple classrooms and work/pull rooms, with specific placement instructions for wall and ceiling locations. The design was completed in January 2025 with a previous design iteration from December 2024.

The technical specifications require all UTP cable to be ANSI/TIA Category 6A standard, with wall locations utilizing surface-mounted single-gang back boxes with white two-port faceplates. The installation includes specific requirements for cable concealment in contractor-provided raceways, service loops for ceiling locations, white 8P/8C (RJ45) jack terminations, and grounding for all cabinets. The drawing includes a floor plan showing multiple classrooms (numbered 401-412) with marked UTP locations, telecom cabinets, and bus bar placements. The design emphasizes standardized mounting heights, particularly in relation to whiteboards, and includes specific requirements for blank keystone jack inserts in unused faceplate ports.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UNIT A

UNIT B

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1 1 1

TGB

SYMBOL LEGEND

WALL UTP LOCATION, QTY AS

NOTED

CEILING UTP LOCATION, QTY AS

NOTED

TELECOM CABINET

TELECOM BUS-BAR

REPLACE CABINETR

B

A

C D

E

FF

GENERAL NOTES

1. ALL UTP CABLE SHALL BE ANSI/TIA CATEGORY 6A.

PLACE WALL LOCATIONS IN A SURFACE MOUNTED

SINGLE-GANG BACK BOX WITH A WHITE TWO

PORT FACEPLATE.

2. THE UNUSED TOP PORT OF THE FACEPLATE IS TO

BE FILLED WITH A BLANK KEYSTONE JACK

INSERT.

3. PLACE WALL LOCATIONS CENTERED BELOW

WHITEBOARD AT STANDARD HEIGHT.

4. LOCATIONS WITHOUT WHITEBOARDS, CENTER

THE INSTALLATION ON THE WALL AT STANDARD

HEIGHT.

5. ALL CABLE BELOW CEILING SHALL BE

CONCEALED IN RACEWAY PROVIDED BY

CONTRACTOR.

6. PROVIDE CEILING LOCATION WITH SERVICE LOOP

LONG ENOUGH TO REACH THE FARTHEST

LOCATION IN THE ASSOCIATED ROOM. SECURELY

FASTEN SERVICE LOOP TO STRUCTURE.

7. TERMINATE ALL CATEGORY 6A CABLES ON WHITE

8P/8C (RJ45) JACKS.

8. LOCATION OF BUS BLOCKS ARE ESTIMATED, USE

BEST PRACTICES FOR INSTALLATION LOCATION.

9. FOR ESTIMATES ASSUME ALL CABINETS NEED

GROUNDING.

C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473

Phone: 810.720.3820 www.ctpartners.net

T E C H N O L O G Y P A R T N E R S

TECHNOLOGY DESIGN I CONSULTING I PLANNING

1/27/2025 DESIGN DLF

12/17/2024 DESIGN EGH

DATE ISSUE AUTHOR

SWARTZ CREEK

COMMUNITY SCHOOLS

STRUCTURED CABLING

SWARTZ CREEK

MIDDLE SCHOOL

MS-T101B

KEYMAP

101B

NTS

M.S. UNIT B

Sheets and Views
MS-T101B

File details come from the government source that posted it. Updated .