ELMS EE-T101-EE-T101.pdf
PDF 224 KB Posted
- Attached to
- 2025 E-Rate Network Cabling Additions
- Solicitation number
- RFP-SCC-250000001194-3
- Issued by
- Genesee County, Michigan
About this file
This is a technology design drawing for structured cabling at Elms Elementary School in the Swartz Creek Community Schools district, created by Convergent Technology Partners. The drawing details specifications for Category 6A UTP cable installation throughout the school building, including wall and ceiling mount locations. The design was created in January 2024 and includes a detailed floor plan showing cable drop locations, telecom cabinets, and bus-bar placements.
The technical specifications require all UTP cable to be ANSI/TIA Category 6A standard, with wall locations using surface-mounted single-gang back boxes with white two-port faceplates. Ceiling locations must include service loops long enough to reach the farthest location in associated rooms. All cabling below ceiling must be concealed in contractor-provided raceway, and all Category 6A cables must terminate on white 8P/8C (RJ45) jacks. The drawing also specifies that all cabinets require grounding, and unused faceplate ports must be filled with blank keystone jack inserts. The installation height requirements are standardized, with wall locations centered below whiteboards or centered on walls without whiteboards at standard height.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 1
1 11 11 11 11 11 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
TGB
SYMBOL LEGEND
UTP LOCATION, QTY AS
NOTED
CEILING UTP LOCATION,
QTY AS NOTED
TELECOM CABINET
TELECOM BUS-BAR
LOW VOLTAGE SLEEVE
REPLACE CABINETR
GENERAL NOTES
1. ALL UTP CABLE SHALL BE ANSI/TIA
CATEGORY 6A. PLACE WALL
LOCATIONS IN A SURFACE MOUNTED
SINGLE-GANG BACK BOX WITH A
WHITE TWO PORT FACEPLATE.
2. THE UNUSED TOP PORT OF THE
FACEPLATE IS TO BE FILLED WITH A
BLANK KEYSTONE JACK INSERT.
3. PLACE WALL LOCATIONS CENTERED
BELOW WHITEBOARD AT STANDARD
HEIGHT.
4. LOCATIONS WITHOUT WHITEBOARDS,
CENTER THE INSTALLATION ON THE
WALL AT STANDARD HEIGHT.
5. ALL CABLE BELOW CEILING SHALL BE
CONCEALED IN RACEWAY PROVIDED
BY CONTRACTOR.
6. PROVIDE CEILING LOCATION WITH
SERVICE LOOP LONG ENOUGH TO
REACH THE FARTHEST LOCATION IN
THE ASSOCIATED ROOM. SECURELY
FASTEN SERVICE LOOP TO
STRUCTURE.
7. TERMINATE ALL CATEGORY 6A CABLES
ON WHITE 8P/8C (RJ45) JACKS.
8. LOCATION OF BUS BLOCKS ARE
ESTIMATED, USE BEST PRACTICES
FOR INSTALLATION LOCATION.
9. FOR ESTIMATES ASSUME ALL
CABINETS NEED GROUNDING.
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
1/23/0225 DESIGN DLF
1/17/2024 DESIGN EGH
DATE ISSUE AUTHOR
SWARTZ CREEK
COMMUNITY SCHOOLS
STRUCTURED CABLING
EE-T101
ELMS ELEMENTARY
SCHOOLT101
NTS
ELMS FLOOR PLAN
| Sheets and Views |
| EE-T101 |
File details come from the government source that posted it. Updated .