HIGH SCHOOL HS-T101-HS-T101F.pdf

PDF 625 KB Posted

Attached to
2025 E-Rate Network Cabling Additions
Solicitation number
RFP-SCC-250000001194-3
Issued by
Genesee County, Michigan

About this file

This is a technical drawing/blueprint from Convergent Technology Partners for structured cabling work at Swartz Creek High School, specifically showing Unit F which includes the gymnasium area. The drawing details the placement of UTP (Unshielded Twisted Pair) cable locations, telecom cabinets, and bus-bar installations. The document specifies that all UTP cable must be ANSI/TIA Category 6A, with specific installation requirements including surface-mounted single-gang back boxes with white two-port faceplates, and proper placement relative to whiteboards at standard height.

The technical specifications include detailed requirements for cable installation, including concealment in contractor-provided raceway below ceiling, service loop requirements, white 8P/8C (RJ45) jack terminations, and grounding requirements for cabinets. The drawing shows layouts for various spaces including a gymnasium, lobby (room 705), boys' team room (716), boys' locker room (713), and girls' locker room (710). The document is dated January 24, 2025, with an earlier design date of December 17, 2024, and was created by Convergent Technology Partners located in Swartz Creek, MI.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UNIT F UNIT F

UNIT G

UNIT F

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

TGB

SYMBOL LEGEND

UTP LOCATION, QTY AS

NOTED

CEILING UTP LOCATION,

QTY AS NOTED

TELECOM CABINET

NEW TELECOM BUS-BAR

EXISTING BUS-BAR

OLD COMPUTER LAB

TGB

B C

A D

E F

G

GENERAL NOTES

1. ALL UTP CABLE SHALL BE ANSI/TIA

CATEGORY 6A. PLACE WALL LOCATIONS IN A

SURFACE MOUNTED SINGLE-GANG BACK BOX

WITH A WHITE TWO PORT FACEPLATE.

2. THE UNUSED TOP PORT OF THE FACEPLATE

IS TO BE FILLED WITH A BLANK KEYSTONE

JACK INSERT.

3. PLACE WALL LOCATIONS CENTERED BELOW

WHITEBOARD AT STANDARD HEIGHT.

4. LOCATIONS WITHOUT WHITEBOARDS,

CENTER THE INSTALLATION ON THE WALL AT

STANDARD HEIGHT.

5. ALL CABLE BELOW CEILING SHALL BE

CONCEALED IN RACEWAY PROVIDED BY

CONTRACTOR.

6. PROVIDE CEILING LOCATION WITH SERVICE

LOOP LONG ENOUGH TO REACH THE

FARTHEST LOCATION IN THE ASSOCIATED

ROOM. SECURELY FASTEN SERVICE LOOP TO

STRUCTURE.

7. TERMINATE ALL CATEGORY 6A CABLES ON

WHITE 8P/8C (RJ45) JACKS.

8. LOCATION OF BUS BLOCKS ARE ESTIMATED,

USE BEST PRACTICES FOR INSTALLATION

LOCATION.

9. FOR ESTIMATES ASSUME ALL CABINETS

NEED GROUNDING.

C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473

Phone: 810.720.3820 www.ctpartners.net

T E C H N O L O G Y P A R T N E R S

TECHNOLOGY DESIGN I CONSULTING I PLANNING

1/24/2025 DESIGN DLF

12/17/2024 DESIGN EGH

DATE ISSUE AUTHOR

SWARTZ CREEK

COMMUNITY SCHOOLS

STRUCTURED CABLING

SWARTZ CREEK HIGH

SCHOOL

HS-T101F

T101F

NTS

HIGH SCHOOL UNIT F KEYMAP

Sheets and Views
HS-T101F

File details come from the government source that posted it. Updated .