HIGH SCHOOL HS-T101-HS-T102.pdf

PDF 341 KB Posted

Attached to
2025 E-Rate Network Cabling Additions
Solicitation number
RFP-SCC-250000001194-3
Issued by
Genesee County, Michigan

About this file

This is a structured cabling design drawing for Swartz Creek Community Schools, specifically for Swartz Creek High School, created by Convergent Technology Partners. The drawing details the telecommunications infrastructure layout for the second floor of the high school, divided into Unit A and Unit B, with specifications for Category 6A UTP cable installations, telecom cabinets, and bus-bar locations. The design was issued on 12/17/2024 and 1/24/2025, with work to include installation of wall-mounted data ports, ceiling UTP locations, and telecom grounding infrastructure.

The technical specifications require all UTP cable to be ANSI/TIA Category 6A, installed in surface-mounted single-gang back boxes with white two-port faceplates, with specific mounting requirements below whiteboards at standard height. The scope includes installation of cable concealment in contractor-provided raceways, service loops for ceiling locations, white 8P/8C (RJ45) jack terminations, and grounding for all cabinets. The drawing shows multiple classroom locations, including former computer lab spaces, and includes detailed placement of telecommunications infrastructure throughout both units of the second floor, including a new locker room area in Unit B.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UNIT 2B

UNIT 2A

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

1 1

1 1

UNIT 2B

UNIT 2A

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

TGB

SYMBOL LEGEND

UTP LOCATION, QTY AS

NOTED

CEILING UTP LOCATION,

QTY AS NOTED

TELECOM CABINET

NEW TELECOM BUS-BAR

EXISTING BUS-BAR

OLD COMPUTER LAB

TGB

A2 B2

GENERAL NOTES

1. ALL UTP CABLE SHALL BE ANSI/TIA

CATEGORY 6A. PLACE WALL LOCATIONS IN A

SURFACE MOUNTED SINGLE-GANG BACK BOX

WITH A WHITE TWO PORT FACEPLATE.

2. THE UNUSED TOP PORT OF THE FACEPLATE

IS TO BE FILLED WITH A BLANK KEYSTONE

JACK INSERT.

3. PLACE WALL LOCATIONS CENTERED BELOW

WHITEBOARD AT STANDARD HEIGHT.

4. LOCATIONS WITHOUT WHITEBOARDS,

CENTER THE INSTALLATION ON THE WALL AT

STANDARD HEIGHT.

5. ALL CABLE BELOW CEILING SHALL BE

CONCEALED IN RACEWAY PROVIDED BY

CONTRACTOR.

6. PROVIDE CEILING LOCATION WITH SERVICE

LOOP LONG ENOUGH TO REACH THE

FARTHEST LOCATION IN THE ASSOCIATED

ROOM. SECURELY FASTEN SERVICE LOOP TO

STRUCTURE.

7. TERMINATE ALL CATEGORY 6A CABLES ON

WHITE 8P/8C (RJ45) JACKS.

8. LOCATION OF BUS BLOCKS ARE ESTIMATED,

USE BEST PRACTICES FOR INSTALLATION

LOCATION.

9. FOR ESTIMATES ASSUME ALL CABINETS

NEED GROUNDING.

C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473

Phone: 810.720.3820 www.ctpartners.net

T E C H N O L O G Y P A R T N E R S

TECHNOLOGY DESIGN I CONSULTING I PLANNING

1/24/2025 DESIGN DLF

12/17/2024 DESIGN EGH

DATE ISSUE AUTHOR

SWARTZ CREEK

COMMUNITY SCHOOLS

STRUCTURED CABLING

SWARTZ CREEK HIGH

SCHOOL

HS-T102

T1012

NTS

H.S. 2ND FLOOR UNIT A

T1012

NTS

H.S. 2ND FLOOR UNIT B

KEYMAP

Sheets and Views
HS-T102