KML Drwgs for Printing 10-15-25.pdf.crdownload
CRDOWNLOAD file 37 MB Posted
- Attached to
- Kent Memorial Library Expansion
- Solicitation number
- 33247
- Issued by
- Litchfield County, Connecticut
About this file
Kent Memorial Library Renovation Project - Architectural and Structural Design Documents
This comprehensive design document package consists of architectural, structural, and site plans prepared by Salamone & Associates, P.C. (architect), Morrissey Engineering, LLC (structural engineer), SLR International Corporation (civil engineer), and Sparc Fire Protection Engineering for the Kent Memorial Library located at 32 North Main Street, Kent, Connecticut. The project involves renovation and expansion of an existing library complex consisting of a 1922 original historic library building, 1958 and 1994 additions, and integration of an adjacent firehouse facility into a unified campus. The renovation includes comprehensive structural upgrades, mechanical and electrical system replacement, new connector construction between buildings, accessibility improvements, and restoration of historic elements. The scope encompasses approximately 11,320 square feet across basement, first floor, and second floor levels, with extensive demolition of non-structural elements, installation of new insulation and exterior finishes, and reconfiguration of interior spaces to support expanded library operations and community room facilities. Design loads follow 2022 Connecticut State Building Code standards including 40 PSF ground snow load, 89 MPH basic wind speed, and seismic design category B requirements.
The project includes detailed specifications for concrete construction (3,000-4,500 PSI compressive strength), structural steel framing (ASTM A992 Grade 50), wood framing (Douglas-Fir and pressure-treated materials), masonry work, and extensive MEP coordination throughout. Foundation design accommodates existing soil conditions with 1.5 tons per square foot bearing capacity and footings minimum 3'-6" below finish grade. The renovation maintains existing historic elements including the original 1922 library's slate roof and exterior brick while incorporating modern energy-efficient systems, fire protection requirements, and accessibility compliance. Financing sources and construction cost information are not specified in the design documents. The project timeline indicates substantial completion anticipated for 2026, with construction activities scheduled to begin spring 2026. Design documentation was finalized in October 2025 and prepared for bidding purposes.
Text of this file
EARTH
INSULATION - RIGID
CONCRETE
CONCRETE BLOCK
BRICK
SAND
WOOD - ROUGH
WOOD - FINISH
PLYWOOD
METAL
PARTICLE BOARD
INSULATION - BATT
GYPSUM
GRAVEL
STONE
MATERIALS_________
A
BUILDING SECTION
LOCATION ON SHEET
SHEET NUMBER
DOOR TAG101
LEVEL
A101
SIM
A4.1
G1
A7.1
B1
A101
SIM
A101
SIM WALL SECTION
LOCATION ON SHEET
SHEET NUMBER
DETAIL
LOCATION ON SHEET
SHEET NUMBER
WINDOW TAG
EXTERIOR ELEVATION
LOCATION ON SHEET
SHEET NUMBER
INTERIOR ELEVATION
LOCATION ON SHEET
SHEET NUMBER
SPOT ELEVATION
NORTH ARROW
109 EXISTING CONTOUR
109 NEW CONTOUR
1 REVISION
DETAIL
LOCATION ON SHEET
SHEET NUMBERA101
SIM
SYMBOLS_________________
ABBREVIATIONS
@ At & And " Inch, Inches ' Foot, Feet # Number or Pound
ABV Above AC Air Conditioning ACOUST Acoustic, Acoustical ACPL Acoustical Plaster ADA Americans with Disabilities Act ADD Addendum ADP Alan D. Paradis, RA AFF Above Finished Floor AHJ Authorities Having Juistiction AIA American Institute of Architects AIEE American Institute of Electrical Engineers AISC American Institute of Steel Construction ALUM Aluminum ANN Annunciator ANOD Anodized AP Access Panel APPROX Approximately ARCH Architect, Architectural ASCE American Society of Civil Engineers ASME American Society of Mechanical Engineers ASPH Asphalt ASTM American Society for Testing and Materials AT Acoustical Tile AT CLNG Acoustical Ceiling, Acoustical Tile Ceiling AUTO Automatic AVG Average
BAS Building Alarm System BD Board BEL Below BIT Bituminous BO Bottom Of BOT Bottom BRZ Bronze BRS Brass BSMT Basement BTU British Thermal Units BTUH British Thermal Units per Hour BTWN Between
C TO C Center to Center CAB Cabinet CAD Computer-Aided Drafting CB Catch Basin CBLK Concrete Block CCTV Closed Circuit Television CCW Counter Clockwise CEM Cement CFM Cubic Feet per Minute CFL Compact Fluorescent CFS Cubic Feet per Second CFT Cubic Foot CHJ Caleb H. Jacobsen CIRC Circumference CJ Control Joint CL Centerline CLEAR Clear Poly-Urethane Finish - Gloss CLL Contract Limit Line CLOS Closet CLNG Ceiling CMU Concrete Masonry Unit COAX Coaxial COL Column CONC Concrete CONST Construction CONT Continuous CONTR Contractor COP Copper CORR Corridor CPT Carpet CS Countersink, Countersunk CT Connecticut CU Cubic CUH Cabinet Unit Heater CW Clockwise CYD Cubic Yard CYL Cylinder
D Drain DB Dark Bronze DC Direct Current DEG Degree DEMO Demolish, Demolition DEPT Department DF Drinking Fountain DH Double Hung DIA Diameter DIAG Diagonal DIFF Diffuser, Diffused DIM Dimension DISL Disposal DISP Dispenser DIV Division DL Dead Load DN Down DP Dampproofing DPR Damper DR Door DS Downspout DSP Dry Standpipe DT Drain Tile DW Dishwasher DWG Drawing DWR Drawer
E East EA Each EIFS Exterior Insulation and Finish System EJ Expansion Joint EL Elevation ELEC Electrical ELEV Elevator, Elevation ELP Emergency Lighting Panel EMER Emergency ENTR Entrance EP Electrical Panel EPDM Ethylene Propylene Diene Monomer EQ Equal EQUIP Equipment EWH Electrical Water Heater EXC Excavate EXG Existing EXH Exhaust EXIST Existing EXP Expansion, Exposed EXT Exterior
F Fahrenheit FA Fire Alarm FAB Fabricate FACP Fire Alarm Control Panel FAG Fire Alarm Gong FAR Floor Area Ratio FBD Fiberboard FC Foot Candle FCAB Filing Cabinet FD Floor Drain FDC Fire Department Connection FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FF&E Fixtures, Furnishings, & Equipment FFE Finished Floor Elevation FGL Fiberglass FHC Fire Hose Cabinet FHR Fire Hose Rack FHS Fire Hose Station FIN Finish FIX Fixture FL Floor FLEX Flexible FM Fire Main FOC Face of Concrete FOF Face of Finish FOS Face of Stud FP Fireproof FPL Fireplace FR Fire Retardent FRGL Fire Rated Glazing FRAME Exposed Framing FT Foot, Feet FTG Footing FURN Furnish, Furniture FVC Fire Calve Cabinet
G Gas GA Gauge GALV Galvanized GC General Contractor GEN General GFI Ground Fault Interuppted GFRC Glass Fiber Reinforced Concrete GL Glass/Glazing GRAN Granite GYP Gypsum GWB Gypsum Wallboard
HB Hose Bibb HC Handicapped HDWR Hardware HDWD Hardwood HL Hydrant Ling HM Hollow Metal HORIZ Horizontal HPW High Pressure Sodium HR Hour Rating HT Height HTR Heater HV High Voltage HVAC Heating, Ventilating, & Air Conditioning HW Hot Water
ID Inside Diameter IN Inch INCAND Incandescent INFO Information INSUL Insulation INT Interior IW Indirect Waste
JAN Janitor JBOX Junction Box JC Janitor's Closet JT Joint
KP Kickplate KW Kilowatt KWH Kilowatt Hour
LA Landscape Architect LAD Ladder LAM Laminate, Laminated LAV Lavatory LB Pound (weight) LCD Liquid Crystal Diode LH Left Hand LIN Linoleum LJW Leonard J. Wyeth, AIA LL Live Load LTG Lighting LWC Light Weight Concrete
MACH Machine MAINT Maintenance MAS Masonry MATL Material MAX Maximum ME Mechanical Engineer MED CAB Medicine Cabinet MEP Mechanical, Electrical, Plumbng MH Manhole MIN Minimum MIR Mirror MISC Miscellaneous MO Masonry Opening MR GWB Moisture Resistant Gypsum Wallboard MTL Metal MTLC Metal Clad
N North NAT Natural NEC Natural Electric Code NFWH Non-Freeze Water Hydrant NAT FIN Natural Finish NI Nickel NIC Not in Contract NO Number NOM Nominal NR Noise Reduction NTS Not to Scale
OC On Center OD Outside Diameter OFF Office OH Overhead OHDR Overhead Door OPP Opposite OVFL Overflow OW Open Waste
PARTN Partition PBD Particle Board PL Property Line PLAM Plastic Laminate PLAS Plaster PLYWD Plywood PNL Panel PNT Paint, Painted PREFAB Prefabricated PSF Pounds per Square Foor PSI Pounds per Square Inch PTD Paper Towel Dispenser PTD/R Combination Paper Towel Dispenser/Receptacle PTR Paper Towel Receptacle
QTY Quantity QT Quarry Tile
R Riser, Radius RB Rubber Base RCP Reflected Ceiling Plan RD Roof Drain REBAR Reinforcing Bar REF Refrigerator REM Remove REQD Required REV Reverse RF Roof RH Right Hand RM Room RO Rough Opening ROW Right of Way RUB Rubber RT Runner Tile RWC Rain Water Conductor RWL Rain Water Leader
S South S&M Surfaced & Matched S&S Stained & Sealed S&V Stain & Varnish SAN Sanitary SC Solid Core SCD Seat Cover Dispenser SCHED Schedule SCR Screen SCW Solid Core Wood SD Soap Dispenser SDH Sara D. Holmes, AIA SE Structural Engineer SF Square Foot SFGL Safety Glass SIM Similar SND Sanitary Napkin Dispenser SPEC Specification SPK Speaker SPP Skim Coat Plaster Panted SS Solid Surface SSTL Stainless Steel ST Stone STL Steel STN Stain(ed) STO Storage STRUC Structure, Structural STW Storm Water SUSP Suspended SWBD Switchboard SY Square Yard SYM Symmetrical
T Tread, Thermostat T&B Top and Bottom T&G Tongue and Groove TBD To Be Determined by Architect TD Trench Drain TEL Telphone TER Terazzo TGL Tempered Glass TH Thermostat TO Top Of TOS Top of Steel TOSL Top of Slab TOW Top of Wall TPD Toilet Paper Dispenser TPTN Toilet Partition TR Tread TRAV Travertine TV Television TYP Typical
UL Underwriters' Laboratories UNO Unless Noted Otherwise USGBC United States Green Building Council
VAR Varnish VB Vapor Barrier VCT Vinyl Compsition Tile VIF Verify in Field VNR Veneer VP Vapor Proof VR Vapor Retarder VRM Vermiculite VS Victoria Su, AIA VCT Vinyl Composition Tile
W West W/ With W/O Without WA Wyeth Architects, LLC WB Wood Base WC Water Closet WD Wood WGL Wired Glass WIN Window WOM Walk-Off Mat WP Waterproof, Weatherproof WPT Working Point WR Water Resistant WS Weatherstripping, Water Stop WDVR Wood Veneer
X GWB Fire-X 5/8" GWB - 2 Layers
1. Perform construction work per Division 1 requirements.
2. Do not scale the drawings. Use dimensions, alignments and notes on the drawing to Locate all elements of construction. Verify that all layouts and alignments fit before beginning construction. Where alignments are required, alignments take precedent over dimensions.r
3. Report any errors, inaccuracies, misalignments, conflicts or missing dimensions to the architect before beginning the work. All communications are to be documented.
4. All work is to comply with applicable State and local codes.
5. Strictly adhere to manufacturer’s written installation and handling instructions and recommendations.
6. Review the intended fire and health-safety code compliance requirements with the architects before beginning work. Plan for fire-resistance ratings to fully encompass the rated spaces. This includes floors and ceilings.
7. Coordinate blocking for all listed and/or drawn items. This includes coordination with furniture and equipment supplied by the Owner.
8. Confirm all Contract Limit Lines in the field. Coordinate with the Owner and the architect: site access, parking, protection, staging and landscape elements to remain.
9. Provide all necessary barriers to protect the site and construction from unauthorized visitors.
10. Verify the locations of existing construction, utilities, site improvements and landscaping elements to remain. Notify the architect of any potential conflicts before beginning work.
11. Coordinate with the Owner and the Town the disposal of unwanted materials. Dispose of all waste materials offsite in a legal manner.
12. Dimensions in the Contract Documents are to rough frame unless noted otherwise.
13. All existing work affected by new construction is to be patched, repaired, cleaned and finished as required to match the quality standards of the new work.
14. Electronic media make it easy to create smaller or larger copies of the graphic Construction Documents. This renders written scales unreliable. The Drawing format is 24” x 36”. Scale references are set to that format only. The GC is responsible to coordinate proper document reproduction scales.
DEFINITIONS - See Division 1 of the Project Manual for more detail:
Furnish Supply and deliver to the Project site, ready for unpacking, assembly, installation and similar operations.
Install Operations at the Project site including the unloading, unpacking, assembly, erection, placing, anchoring, applying, working to dimension, finishing, curing, protecting, cleaning and similar operations.
Provide Furnish and install.
Or approved equal Means: approved by the Architect.
GENERAL NOTES_____________________________________________________________________
Contract Date
Drawn by
Checked by
Revisions & Notes
Code
Structural
MEP
Scale
Salamone & Associates, P.C.
116 North Plains Industrial Road Wallingford, CT 06492 P: 203 281 6895 F: 203 287 8728 W: salamoneassoc.com
Morrissey Engineering, LLC 58 Essex Street Deep River, CT 06417 P: 860 532 0312 W: morrisseyengineers.com
Sparc Fire Protection Engineering P: 203 391 6633, 212 392 5868 W: sparcfp.com
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G Issue Date
L I N E W I L L M E A S U R E 0' - 4" A T F U L L S C A L E
Civil
SLR International Corporation 99 Realty Drive Cheshire, CT 06037 P: 203 271 1773 W: slrconsulting.com
/2 /2
:0
:4
A M
As indicated
T1
TITLE SHEET
K e n t
M e m o ri a l L ib ra ry
11/1/21
SDH
LJW
N o rt h
M a in S tr e e t, K e n t, C T
10/15/25
DRAWING LIST________________________________________________________________________________
Sheet Number Sheet Name
General
T1 TITLE SHEET
T2 LIFE SAFETY
Civil
C1.01 EXISTING CONDITIONS
C1.02 SITE LAYOUT
C1.03 GRADING & UTILITIES
C1.04 SEDIMENTATION & EROSION CONTROLS
C1.05 SITE DETAILS
C1.06 SITE DETAILS
C1.07 SITE DETAILS
C1.08 SITE DETAILS
Architectural Site
AS0.1 SITE PLAN
AS1.0 SITE DETAILS
Architectural
D1.1 FIRST FLOOR AND SITE DEMOLITION PLAN
D1.2 SECOND FLOOR AND ROOF DEMOLITION
D3.1 DEMOLITION ELEVATIONS
Architectural
A1.0 BASEMENT AND FOUNDATION PLAN
A1.1 FIRST FLOOR PLAN OVERALL
A1.1A FIRST FLOOR PLAN - NORTH
A1.1B FIRST FLOOR PLAN - SOUTH
A1.2 SECOND FLOOR PLAN COMMUNITY ROOM
A1.3 ROOF PLAN
A2.1A REFLECTED CEILING PLAN - NORTH
A2.1B REFLECTED CEILING PLAN - SOUTH
A2.2 FIREHOUSE SECOND FLOOR RCP
A3.1 EXTERIOR ELEVATIONS
A3.2 EXTERIOR ELEVATIONS
A3.3 ORIGINAL HISTORIC LIBRARY ELEVATIONS
A3.4 LIBRARY ADDITIONS ELEVATIONS
A3.5 CONNECTOR ELEVATIONS
A3.6 FIREHOUSE ELEVATIONS SOUTH & WEST
A3.7 FIREHOUSE ELEVATIONS NORTH & EAST
A4.1 LIBRARY BUILDING SECTIONS
A4.2 LIBRARY BUILDING SECTIONS
A4.3 CONNECTOR BUILDING SECTIONS
A4.4 FIREHOUSE AND TOWER BUILDING SECTIONS
A5.1 WALL SECTIONS - 1994 & 1958 ADDITIONS
A5.2 WALL SECTIONS - FIREHOUSE
A5.3 WALL SECTIONS - CONNECTOR
A5.4 SECTION DETAILS - CONNECTOR
A5.5 PLAN DETAILS - CONNECTOR
A5.6 MECHANICAL SHAFT
A5.7 ROOF DETAILS - EXG LIBRARY AND GENERAL
A5.8 ROOF DETAILS - CONNECTOR
A5.9 EXTERIOR DETAILS
KENT MEMORIAL LIBRARY
Kent, Connecticut
Sheet Number Sheet Name
A6.1 ENLARGED BATHROOM PLANS
A6.1 ALT3 CERAMIC TILE
A6.2 ENLARGED BATHROOM PLANS
A6.2 ALT3 CERAMIC TILE
A6.3 ELEVATOR
A6.4 FIRE ESCAPE DETAILS
A7.1 INTERIOR ELEVATIONS - READING ROOM
A7.2 INTERIOR ELEVATIONS LOBBY & VESTIBULE
A7.3 INTERIOR ELEVATIONS CIRCULATION
A7.4 INTERIOR ELEVATIONS COMMONS & MEETING
ROOMS
A7.5 INTERIOR ELEVATIONS OFFICE AREAS
A7.6 INTERIOR ELEVATIONS CHILDRENS ROOMS
A7.7 INTERIOR ELEVATIONS FIREHOUSE LOWER
LEVEL
A7.8 INTERIOR ELEVATIONS FIREHOUSE
COMMUNITY ROOM
A8.1 INTERIOR DETAILS
A8.2 LOBBY STAIR
A8.3 LOBBY STAIR
A8.4 COMMUNITY ROOM DETAILS
A9.1 MILLWORK - CIRCULATION DESK
A9.2 MILLWORK DETAILS
A10.1 ROOM FINISH SCHEDULE
A10.2 DOOR SCHEDULE & TYPES
A10.3 WINDOW SCHEDULES
A10.5 ALUMINUM WINDOWS & WINDOW WALL
A10.7 WALL TYPES & SCHEDULE
A11.1A FIRST FLOOR DIMENSION PLAN - NORTH
A11.1B FIRST FLOOR DIMENSION PLAN - SOUTH
A11.2 SECOND FLOOR DIMENSION PLAN
Structural
S1.0 GENERAL NOTES
S1.1 FOUNDATION AND FIRST FLOOR PLAN
S1.2 SECOND FLOOR FRAMING PLAN
S1.3 ROOF FRAMING PLAN
S2.1 TYPICAL DETAILS
S2.2 TYPICAL DETAILS
S3.1 SECTIONS
S3.2 SECTIONS
S3.3 SECTIONS
S3.4 SECTIONS
Sheet Number Sheet Name
Mechanical
M0.1 FIRST FLOOR MECHANICAL DEMOLITION
PLANS
M0.2 BASEMENT AND SECOND FLOOR MECHANICAL
DEMOLITION PLANS
M1.1 FIRST FLOOR MECHANICAL PLAN
M1.2 BASEMENT AND SECOND FLOOR MECHANICAL
PLANS
M2.1 MECHANICAL DETAILS AND DIAGRAMS
M3.1 MECHANICAL SCHEDULES, NOTES, SYMBOLS
AND ABBREVIATIONS
Electrical
E0.1 FIRST FLOOR ELECTRICAL DEMOLITION PLAN
E0.2 BASEMENT / SECOND FLOOR / ATTIC SPACE
ELECTRICAL DEMOLITION PLAN
E1.1 FIRST FLOOR ELECTRICAL PLAN
E1.2 BASEMENT AND SECOND FLOOR ELECTRICAL
PLAN
E2.1 FIRST FLOOR LIGHTING PLAN
E2.2 BASEMENT AND SECOND FLOOR LIGHTING
PLANS
E3.1 FIRST FLOOR FIRE ALARM PLAN
E3.2 BASEMENT AND SECOND FLOOR FIRE ALARM
PLANS
E4.1 ELECTRICAL PANELBOARD SCHEDULES
E5.1 ELECTRICAL RISER DIAGRAMS
E6.1 ELECTRICAL DETAILS
E7.1 ELECTRICAL SCHEDULES, SYMBOLS, NOTES,
AND ABBREVIATIONS
SE1.1 ELECTRICAL SITE PLAN
Plumbing
P0.1 FIRST FLOOR PLUMBING DEMOLITION PLANS
P0.2 BASEMENT AND SECOND FLOOR PLUMBING
DEMOLITION PLANS
P1.1 FIRST FLOOR PLUMBING DOMESTIC WATER
PLAN
P1.2 BASEMENT AND SECOND FLOOR PLUMBING
AND DOMESTIC WATER PLANS
P2.1 FIRST FLOOR PLUMBING SANITARY AND VENT
PLAN
P2.2 BASEMENT AND SECOND FLOOR PLUMBING
SANINTARY AND VENT PLANS
P3.1 PLUMBING SCHEDULES, SYMBOLS, NOTES,
AND ABBREVIATIONS
Fire Protection
FP1.1 FIRST FLOOR FIRE PROTECTION PLAN
FP1.2 BASEMENT AND SECOND FLOOR FIRE
PROTECTION PLAN
FP2.1 FIRE PROTECTION NOTES AND DETAILS
No. Description Date
UP
UP
DN
DN
UP
UP
DN
DN
UP
497 SF
READING ROOM
50B 36"
36"
36"
36"
36"
36"
36"
NON-EGRESS
149 SF
CHILDREN'S DOUBLE OFFICE
150B
182 SF
YOUNG ADULT
15B
407 SF
CHILDREN'S AREA
118A
50A-3
118 SF
MTG RM 1
15B
117 SF
MTG RM 2
15B
1405 SF
ADULT STACKS
100A-3
59 SF
FAMILY BATHROOM
150B
94 SF
PROGRAM
150B
464 SF
TECH SERVICES
150B
125 SF
CIRCULATION
150B
144 SF
DIRECTOR
150B
94 SF
ADMIN ASST
150B
601 SF
LOBBY
150B
94 SF
VESTIBULE
150B
121 SF
MECHANICAL
300S-2
155 SF
MEN'S BATHROOM
150B
218 SF
WOMEN'S BATHROOM
150B
102 SF
ELEC
300S-2
363 SF
NEW MATERIALS
150B
614 SF
CHILDREN'S STACKS
118B
100A-3
344 SF
COMMON
150B
33 SF
COPY/PRINT
150B
GROSS BUSINESS
AREA 1/150=
OCCUPANCY 3
GROSS BUSINESS
AREA 1/150= 1488 gsf
@ 150 SF/OCC = 10
36"
CHILDRENS ROOM OCCUPANCY IS
CALCULATED AS PARTIAL STACK
AREA @ 100 GSF, AND PARTIAL
ASSEMBLY AREA WITH TABLES,
CHAIRS @ 15 NSF.
36"
TD: 83' - 5"
TD: 89' - 0"
MAX TD: 76'
CP TD: 33' - 5"
509 SF
EXG LOFT
150B
630 SF
COMMUNITY ROOM
7A-1
138 SF
STORAGE
300S-2
107 SF
WARMING PANTRY
300S-2
53 SF
H/C UNISEX
150B
TD = 77' - 2"
COMMUNITY ROOM IS CALCULATED
AS NET AREA OF OCCUPIABLE
SPACE AFTER WALLS, AND
REQUIRED EGRESS PATHS AND
AISLES REQUIRED TO REMAIN OPEN
ARE SUBTRACTED. MAXIMUM
OCCUPANCY FOR ASSEMBLY WILL
BE POSTED AT ENTRY.
23 SF
EXG UNISEX
150B
MAX TD = 108'
TD = 117' - 8"
EXIT TO GRADE
MAIN BUILDING ENTRANCE
BUILDING ENTRANCE
CODE PLAN LEGEND
MAXIMUM TRAVEL DISTANCE
DEAD END TRAVEL DISTANCE
MAX TD = X' - X"
COMMON PATH TRAVEL DISTANCE
1 HOUR HORIZONTAL ASSEMBLY - SEE ROOM SCHEDULE A10.1
& DOOR SCHEDULES A10.2 & 10.3
NOTE:
1. SPACES RATED FOR FIRE INCLUDES WALLS, CEILINGS,
STRUCTURE, AND FLOORS.
2. RATED OPENINGS INCLUDE COMPLETE ENCLOSURE.
DE TD = X' - X"
CP TD = X' - X"
1 HOUR RATED ASSEMBLY WITH 3/4 HOUR RATED OPENINGS
ROOM NAME
150 SF
x 0B
ROOM NUMBER
ROOM SQUARE FOOTAGE
OCCUPANT LOAD
OCCUPANT LOAD FACTOR
GROUP CLASSIFICATION
36" DOOR WIDTH
APPLICABLE CODES/STANDARDS
The subject building will be analyzed with respect to fire protection and life safety provisions of the following current codes and standards adopted in the state of Connecticut:
• International Building Code, 2021 Edition (IBC)
• As adopted and amended by the 2022 Connecticut State Building Code.
• International Existing Building Code, 2021 Edition (EBC)
• As adopted and amended by the 2022 Connecticut State Building Code.
• The International Fire Code, 2021 Edition (IFC)
• As adopted and amended by Part III of the 2022 Connecticut Fire Safety Code.
• NFPA 101, 2021 Edition
• As adopted and amended by Part IV of the 2022 Connecticut Fire Safety Code.
• Fire Code, NFPA 1, 2021 Edition
• As adopted and amended by the 2022 Connecticut Fire Prevention Code.
OCCUPANCIES AND USES
Occupant Load per Floor:
HEIGHT AND AREA
Type VB construction type as defined by IBC, Section 602.5 appears to be the existing library construction type and is used for this analysis.
Type VB construction permits 60 ft. height for fully sprinklered buildings and two-stories (Table 504.3 & 504.4).
The library has a total area of 11,320 square feet (1,272 gross sq. ft. Basement; 8,181 gross sq. ft. Ground Floor; 1,867 gross sq. ft. 2nd Floor).
FIRE-RESISTANCE RATING (INTERIOR)
The required fire-resistance ratings for specific interior elements or spaces are indicated in the table below. The separations are required to be made with fire barriers and/or horizontal assemblies complying with Sections 707 and 711, respectively.
Fire-Resistance Rating of Elements or Spaces:
PENETRATIONS
Smoke dampers are required to be Class I or II leakage rated and elevated temperature rating of not less than 250°F [BC 717.3.2.2]. Where combination fire/smoke dampers are installed, they are required to meet both requirements for smoke and fire dampers.
FIRE PROTECTION SYSTEMS
The requirements for fire protection systems are found in Chapter 9 of the BC. Sprinkler systems and fire alarm systems are required based on the occupancy.
The library will not be required to have a standpipe system, as the highest occupied floor is less than 30 ft. above the lowest point of fire department access.
FIRE ALARM AND DETECTION SYSTEMS
Fire alarm and detection to be provided through the building as required by the BC for new construction.
Manual fire alarm boxes (e.g. pull stations) are not required when the building is fully sprinklered.
System is still required one (1) manual pull station at an approved location per 907.2.
A fire alarm and emergency voice/alarm communication system is not required to be provided in the library in accordance with Section 907.2.1 and 907.5.2.2, as the occupant load is less than 1,000.
MEANS OF EGRESS
The requirements of BC Chapter 10 will be used to determine the means of egress requirements of the library.
EGRESS CAPACITY
PLUMBING FIXTURE COUNTS
Provided:
CODE INFORMATION
Occupancy Use Group Occ. Load factor Function of Space
Assembly A-1 7 net Assembly without fixed seats - Concentrated (chairs only -- not fixed)
Assembly A-1 15 net Assembly without fixed seats - Unconcentrated (tables and chairs)
Assembly A-3 100 gross Library (stack area), art gallery
Assembly A-3 50 net Library (reading room)
Business B 150 gross Offices
Business B 15 net Assembly without fixed seats (small conference rooms)
Storage S-2 300 gross Low-hazard accessory storage areas, mechanical equipment rooms
Element or Space Ratings (hr)
Enclosure of Vertical Exits [1023.2 BC] 1 (Less than 4 stories)
Hoistways and Shafts [713.4 BC] 1 (penetrating fewer than 3 stories)
Structural Members Supporting a Wall or other Same as the required fire-resistance rating of the wall/barrier supported, but not less fire-resistance construction [704.1 BC] than the rating required for the member by the construction classification.
Male WC Female WC Unisex Lavatory Drink Fount. Serv. Sink
3 3 3 9 2 1
Component Required Width Minimum Width Provided Width
Stairs 0.3 in/occupant 44 in 44" minimum
Doors 0.2 in/occupant 32 in clear 32" minimum
Corridors 0.2 in/occupant 44 in - 24 in for MEP equip
Ramps 0.2 in/occupant 36 in 51 in
Aisles 0.3 in/occupant 36 in 36 in minimum
Level Occupancy Load
Basement 4
First Floor 96
Loft 5
Second Floor 95
Total 210
540 SF
EXG MECH / ELEC
300S-2
588 SF
MECH / ELEC
300S-2
Contract Date
Drawn by
Checked by
Revisions & Notes
Code
Structural
MEP
Scale
Salamone & Associates, P.C.
116 North Plains Industrial Road Wallingford, CT 06492 P: 203 281 6895 F: 203 287 8728 W: salamoneassoc.com
Morrissey Engineering, LLC 58 Essex Street Deep River, CT 06417 P: 860 532 0312 W: morrisseyengineers.com
Sparc Fire Protection Engineering P: 203 391 6633, 212 392 5868 W: sparcfp.com
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G Issue Date
L I N E W I L L M E A S U R E 0' - 4" A T F U L L S C A L E
Civil
SLR International Corporation 99 Realty Drive Cheshire, CT 06037 P: 203 271 1773 W: slrconsulting.com
/2 /2
:3 :4
A
M
As indicated
T2
LIFE SAFETY
K e n t
M e m o ri a l L ib ra ry
11/1/21
SDH
LJW
N o rt h
M a in S tr e e t, K e n t, 10/15/25
1/16" = 1'-0" D1
CODE First Floor
1/16" = 1'-0" G1
CODE Second
1/16" = 1'-0" F5
CODE Basement
CONCRETE S
IDEWALK
X X
X X
X
X X
X
CB
#28 NORTH MAIN STREET
BUILDING
#32 NORTH MAIN STREET
BUILDING
CONC.
CONC. BITUMINOUS SIDEWALK
CB
CB
CB
CB
CONCRETE
PATIO
SLATE
PATIO
S L
A T
E P
A T
IO
BIRD
BATH
B
IT
U M
IN
O
U S
S
ID
E W
A
LK CONCRETE STEP
B
IT
U M
IN
O
U S
ID
E
W A
LK
SLATE WALK
#30 NORTH MAIN STREET
BUILDING
CONC.
C O N C.
OIL
FILLER
B
IT
. W A
LK
CONC.
CONCRETE APRON
C O
N C
R E
T E
W A
L K
B I L C O
D O O R
GRAVEL P
ARKING A
REA
ED
G
E O F B
IT
U
M
IN
O U
S
G R
A V
E L
P
A R
K
IN
G
R E
A
AC-UNIT
DOOR SILL
EL.= 399.53'
FLOOR
EL.= 398.84'
DOOR SILL
EL.= 398.13'
FLOOR
EL.= 398.83'
DOOR SILL 1ST. FLR. EL.= 399.01'
DOOR SILL 2ND FLR. EL.= 411.18'
DOOR SILL
EL.= 398.92'
DOOR SILL
EL.= 399.1'
FLAG
POLE
E
CHARGE
STATION
PLT.
PLT.
PLT.
PLT.
PLANTING
CONC.
CONC.
RIM 396.06'
INV 393.10± (6")
INV 392.52± (15")
PLT.
R C
P
6" PV
C
Contract Date
Drawn by
Checked by
No. Description Date
Revisions & Notes
Code
Structural
MEP
Scale
Salamone & Associates, P.C.
116 North Plains Industrial Road Wallingford, CT 06492 P: 203 281 6895 F: 203 287 8728 W: salamoneassoc.com
Morrissey Engineering, LLC 58 Essex Street Deep River, CT 06417 P: 860 532 0312 W: morrisseyengineers.com
Sparc Fire Protection Engineering P: 203 391 6633, 212 392 5868 W: sparcfp.com
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G Issue Date
CIVIL
SLR International Corporation 99 Realty Drive Cheshire, CT 06037 P: 203 271 1773 W: slrconsulting.com
K E
N T
M E
M O
R
IA
L
LI
B R
A R
Y
N O
R
TH
M
AI
N S
TR
EE
T
EXISTING
CONDITIONS
C-1.01 1" = 20'
TDR
DSR
October 20, 2025
September 25, 2024
Se pt em be r 2 5, NOTES:
1. BOUNDARY AND TOPOGRAPHIC INFORMATION HAVE BEEN TAKEN FROM SURVEY ENTITLED
"TOPOGRAPHIC SURVEY", PREPARED BY ROBERT L. HOCK LICENSED LAND SURVEYOR LLC,
PREPARED FOR KENT LIBRARY ASSOCIATION INC, DATED MARCH 18, 2022, SCALED 1"=10'.
2. NORTH ARROW AND BEARINGS ARE BASED UPON N.Y., N.H., AND H.R.R MONUMENTAL AZIMUTH.
3. ELEVATIONS, CONTOUR AND BENCHMARKS ARE BASED UPON NGVD 29.
4. INFORMATION REGARDING THE LOCATION OF EXISTING UTILITIES HAS BEEN BASED UPON
AVAILABLE INFORMATION AND MAY BE INCOMPLETE, AND WHERE SHOWN SHOULD BE
CONSIDERED APPROXIMATE. THE LOCATION OF ALL EXISTING UTILITIES SHOULD BE
CONFIRMED PRIOR TO BEGINNING CONSTRUCTION. CALL "CALL BEFORE YOU DIG",
1-800-922-4455. ALL UTILITY LOCATIONS THAT DO NOT MATCH THE VERTICAL OR HORIZONTAL
CONTROL SHOWN ON THE PLANS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE
ENGINEER FOR RESOLUTION.
5. SLR INTERNATIONAL CORPORATION ACCEPTS NO RESPONSIBILITY FOR THE ACCURACY OF MAPS
AND DATA WHICH HAVE BEEN SUPPLIED BY OTHERS.
S 54°10'38" E 7.00'
X X
X X
X
X X
X
CB
#28 NORTH MAIN STREET
BUILDING
#32 NORTH MAIN STREET
BUILDING
CONC.
CONC. BITUMINOUS SIDEWALK
CB
CB
CB
CB
CONCRETE
PATIO
SLATE
PATIO
S L
A T
E P
A T
IO
BIRD
BATH
B
IT
U M
IN
O
U S
S
ID
E W
A
LK CONCRETE STEP
B
IT
U M
IN
O
E
W A
LK
SLATE WALK
#30 NORTH MAIN STREET
BUILDING
CONC.
C O N C.
OIL
FILLER
B
IT
. W A
LK
CONC.
CONCRETE APRON
C O
N C
R E
T E
W A
L K
B I L C O
D O O R
GRAVEL P
ARKING A
REA
ED
G
E O F B
IT
U
M
IN
O U
S
G R
A V
R
K
E
A
S
°4
'4
" E
.9
N 31°05'52" E 32.29'
S 01°48'20" E
105.02'
S 01°03'57" E
55.06'
S 04°03'57" E
23.86'
N 31°05'23" E 108.50'
N
°2
'5
" W
.4
N 57°14'58" W 20.46'
N
°1
'3
W
.6
AC-UNIT
DOOR SILL
EL.= 399.53'
FLOOR
EL.= 398.84'
DOOR SILL
EL.= 398.13'
FLOOR
EL.= 398.83'
DOOR SILL 1ST. FLR. EL.= 399.01'
DOOR SILL 2ND FLR. EL.= 411.18'
DOOR SILL
EL.= 398.92'
DOOR SILL
EL.= 399.1'
FLAG
POLE
E
CHARGE
STATION
PLT.
PLT.
PLT.
PLT.
PLANTING
CONC.
CONC.
RIM 396.06'
INV 393.10± (6")
INV 392.52± (15")
PLT.
R C
P
6" PV
C
EXISTING
BUILDING
BUILDING
ADDITION
EXISTING
BUILDING
RAILROAD STREET (P
RIVATE ROAD)
NORTH MAIN STREET (RTE. 7)
LA
N
E S
TR
EET
15' 6.5'
2' 2'
TREE TO BE
REMOVED
6' FENCE
CONCRETE PAD
(TYP. OF 2)
4' WIDE CONCRETE
SIDEWALK
CONCRETE
LANDING
GATE
(TYP. OF 2)
FREE STANDING FIRE
DEPT. CONNECTION
TRANSFORMER PAD
(REFER TO ELECTRICAL DESIGN)
FLUSH GRANITE CURB
6' PRIVACY FENCE
PROPERTY
LINE
EXISTING FLAG
POLE TO REMAIN
EXISTING
CHARGING
STATION TO
REMAIN
EXISTING SIGNS
TO REMAIN
ROCK WITH
PLAQUE
TO REMAIN
EXISTING ELM
TREE TO REMAIN
5' WIDE
CONCRETE
SIDEWALK
5' WIDE
CONCRETE
SIDEWALK
4' WIDE
CONCRETE
SIDEWALK
5' WIDE
CONCRETE
SIDEWALK
SAWCUT EXISTING
BITUMINOUS CONCRETE
PAVEMENT
CONCRETE
LANDING
DONOR BRICKS
POLAR ENGRAVING &
TILE ENGRAVERS
COLOR: RED QUARRY
PATTERN: RUNNING
OR STACK BOND
SAWCUT CONCRETE
SIDEWALK AT EXISTING
CONSTRUCTION JOINTS
BITUMINOUS CONCRETE
SERVICE DRIVEWAY
SAWCUT EXISTING
CONCRETE SIDEWALK
REMOVE AND RESET
GRANITE CURB
CONCRETE
LANDING (TYP.)
HARDSCAPE "B"
REFER TO SHEET
AS0.1
SEAT WALL
(DESIGN BY OTHERS)
6" SAN.
INV 396.0 (V.I.F.)
INSULATE SANITARY
PIPE AND ENCASE IN
CONCRETE TO MANHOLE
INSTALL EDGE RESTRAINT ALONG CONCRETE AND BRICKPAVERS (TYP.)
END OF
SEAT WALL
PROPERTY LINE
BOLLARDS
APPROX. LOCATION
OF EXISTING SANITARY
STRUCTURE (TO BE REMOVED)
15'
R10.5'
R5'
LANDSCAPING AREA WITHIN
RAISED GRANITE CURB
END CURB
(FLUSH)
REMOVE
EXISTING
FENCE
REMOVE
EXISTING
FENCE
6" SAN.
INV 396.0 (V.I.F.)
INSULATE SANITARY
PIPE AND ENCASE IN
CONCRETE TO MANHOLE HARDSCAPE "A"
PAVING STONES
REFER TO SHEET AS0.1
HARDSCAPE "A"
REFER TO SHEET
AS0.1
REMOVE SLATE AND
BITUMINUOUS WALKWAYS
REPLACE WITH LAWN
REMOVE
CONCRETE
LANDING
REMOVE SLATE PATIO
REPLACE WITH LAWN
FIRE STAIRCASE
DETECTABLE
WARNING
STRIP
TRASH AND
RECYCLING BINS
RIVER STONE
MULCH
RIVER
STONE
MULCH
RIVER
STONE
MULCH
GRANITE CURB
(TYP.)
Contract Date
Drawn by
Checked by
No. Description Date
Revisions & Notes
Code
Structural
MEP
Scale
Salamone & Associates, P.C.
116 North Plains Industrial Road Wallingford, CT 06492 P: 203 281 6895 F: 203 287 8728 W: salamoneassoc.com
Morrissey Engineering, LLC 58 Essex Street Deep River, CT 06417 P: 860 532 0312 W: morrisseyengineers.com
Sparc Fire Protection Engineering P: 203 391 6633, 212 392 5868 W: sparcfp.com
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G Issue Date
CIVIL
SLR International Corporation 99 Realty Drive Cheshire, CT 06037 P: 203 271 1773 W: slrconsulting.com
K E
N T
M E
M O
R
IA
L
LI
B R
A R
Y
N O
R
TH
M
AI
N S
TR
EE
T
SITE LAYOUT
C-1.02 1"=20'
TDR
DSR
October 20, 2025
September 25, 2024
Se pt em be r 2 5, NOTES:
1. ALL UTILITY SERVICES ARE TO BE UNDERGROUND. THE EXACT LOCATION AND SIZE OF ELECTRIC, TELEPHONE, CABLE TELEVISION, SANITARY SEWER AND PUBLIC WATER ARE TO BE DETERMINED BY THE RESPECTIVE UTILITY COMPANIES.
2. ALL STORM PIPING SHALL BE HIGH DENSITY POLYETHYLENE PIPE (HDPE) UNLESS OTHERWISE NOTED.
3. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS INDICATE FINISHED GRADE.
4. ALL GRAVITY SANITARY SEWER PIPE SHALL BE SDR35 UNLESS OTHERWISE NOTED.
5. PROVIDE MINIMUM VERTICAL SEPARATION OF 18" BETWEEN WATER SERVICE AND SEWER SERVICE.
6. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ANY UTILITIES INCLUDING IRRIGATION PIPES PRIOR TO THE START OF
CONSTRUCTION.
7. ALL DIMENSIONS AND ELEVATIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER.
8. ALL CONSTRUCTION MATERIALS AND METHODS SHALL CONFORM TO THE TOWN OF KENT REQUIREMENTS AND TO THE APPLICABLE SECTIONS OF THE STATE OF CONNECTICUT DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROADS, BRIDGES, FACILITIES AND INCIDENTAL CONSTRUCTION, FORM 818 AND ADDENDUMS.
9. A MAXIMUM FINISHED SLOPE OF 5.0% SHALL BE PROVIDED FOR ALL WALKWAYS AND HARDSCAPE AREAS AND A MAXIMUM FINISHED SLOPE OF 2.0% SHALL BE PROVIDED FOR ALL CONCRETE LANDINGS, IN ACCORDANCE WITH ADA ACCESSIBILITY
STANDARDS.
10. A MINIMUM FINISHED SLOPE OF 1.0% SHALL BE PROVIDED IN ALL SITE AREAS TO ALLOW FOR SURFACE DRAINAGE.
11. ROOF DRAIN DOWNSPOUTS THAT ARE NOT CONNECTED TO ROOF DRAIN COLLECTOR PIPING SHALL DISCHARGE ONTO THE GROUND SURFACE WHICH HAS BEEN STABILIZED WITH CRUSHED STONE, GRAVEL OR A CONCRETE SPLASH PAD.
12. ALL WORK WITHIN THE CONNECTICUT DEPARTMENT OF TRANSPORTATION (CTDOT) ROADWAY RIGHT-OF-WAY REQUIRES THE
CONTRACTOR TO OBTAIN AN ENCROACHMENT PERMIT FROM CTDOT.
S 54°10'38" E 7.00'
X X
X X
X
X X
X
CB
#28 NORTH MAIN STREET
BUILDING
#32 NORTH MAIN STREET
BUILDING
CONC.
CONC. BITUMINOUS SIDEWALK
CB
CB
CB
CB
CONCRETE
PATIO
SLATE
PATIO
S L
A T
E P
A T
IO
BIRD
BATH
B
IT
U M
IN
O
U S
S
ID
E W
A
LK CONCRETE STEP
B
IT
U M
IN
O
E
W A
LK
SLATE WALK
#30 NORTH MAIN STREET
BUILDING
CONC.
C O N C.
OIL
FILLER
B
IT
. W A
LK
CONC.
CONCRETE APRON
C O
N C
R E
T E
W A
L K
B I L C O
D O O R
GRAVEL P
ARKING A
REA
ED
G
E O F B
IT
U
M
IN
O U
S
G R
A V
R
K
E
A
S
°4
'4
" E
.9
N 31°05'52" E 32.29'
S 01°48'20" E
105.02'
S 01°03'57" E
55.06'
S 04°03'57" E
23.86'
N 31°05'23" E 108.50'
N
°2
'5
" W
.4
N 57°14'58" W 20.46'
N
°1
'3
W
.6
AC-UNIT
DOOR SILL
EL.= 399.53'
FLOOR
EL.= 398.84'
DOOR SILL
EL.= 398.13'
FLOOR
EL.= 398.83'
DOOR SILL 1ST. FLR. EL.= 399.01'
DOOR SILL 2ND FLR. EL.= 411.18'
DOOR SILL
EL.= 398.92'
DOOR SILL
EL.= 399.1'
FLAG
POLE
E
CHARGE
STATION
PLT.
PLT.
PLT.
PLT.
PLANTING
CONC.
CONC.
RIM 396.06'
INV 393.10± (6")
INV 392.52± (15")
PLT.
R C
P
6" PV
C
E E
E
E
E
E
E
EXISTING
BUILDING
BUILDING
ADDITION
FFEL 399.0
EXISTING
BUILDING
RAILROAD STREET (P
RIVATE ROAD)
NORTH MAIN STREET (RTE. 7)
LA
N
E S
TR
EET
FREE STANDING FIRE
DEPT. CONNECTION
TRANSFORMER PAD
(REFER TO ELECTRICAL DESIGN)
PROPERTY
LINE
EXISTING ELM
TREE TO REMAIN
APPROXIMATE LOCATION OF
PROPOSED UTILITY CONDUITS
(REFER TO ELECTRICAL DESIGN)
8" HDPE DRAIN
INV 393.1
YARD DRAIN (A)
RIM 397.0
INV 393.6
EXISTING
UNDERGROUND
UTILITY SERVICE
DECOMMISSION EXISTING WATER AND
SANITARY SEWER SERVICES PER
UTILITY REQUIREMENTS
CONTRACTOR TO VERIFY SIZE,
DEPTH AND MATERIAL OF
EXISTING SANITARY SEWER MAIN
CORE DRILL EXISTING SANITARY MAIN AND
INSTALL 6" SERVICE CONNECTION WITH TAPPING
SADDLE PER WATER POLLUTION CONTROL
AUTHORITY STANDARDS
CONTRACTOR TO VERIFY SIZE,
DEPTH AND MATERIAL OF
EXISTING WATER MAIN
1 12" DOMESTIC WATER SERVICE
MAINTAIN SURFACE DRAINAGE FLOW
FROM EXISTING ROOF DRAIN
DISCHARGES ALONG NORTH SIDE OF
BUILDING ONTO LIBRARY PROPERTY
AND AWAY FROM BUILDING
YARD DRAIN (B)
RIM 398.5
INV 394.7
YARD DRAIN (A)
RIM 397.2
INV 395.2
8" HDPE
8" HDPE
8" H
D
PE
6" H
D
PE
8" H
DP
E
8" H
DP
E6"
H D
PE
6" H
D
PE
SAN. MH
RIM 398.0
INV 394.9 (2 - 6" PVC IN)
INV 394.8 (6" PVC OUT)
6" SDR35
PVC SAN.
6" SDR35 PVC SANITARY
SERVICE AT 1/4" PER FOOT MIN.
SEAT WALL
(DESIGN BY OTHERS)
TW 400.0
BW 398.0
6" SAN.
INV 396.0 (V.I.F.)
INSULATE SANITARY
PIPE AND ENCASE IN
CONCRETE TO MANHOLE
398.1 399.0
399.0
399.0
398.2
399.0 399.0
399.0
398.6
398.8399.0
399.0 398.9
398.8
398.8 399.0
399.0
398.6398.8
399.0
399.0 399.0
398.8
399.0
397.5
398.1
397.2
397.3 397.3 397.3
397.4
397.3
397.0
397.5 397.3
397.9
397.9
397.8
397.6
397.3
397.7
397.6
398.8
398.4
398.8398.8
TW 400.8
BW 398.8
PROPERTY LINE
INSTALL NEW WATER MAIN
SERVICE CONNECTIONS PER
WATER COMPANY STANDARDS
APPROX. LOCATION
OF EXISTING SANITARY
STRUCTURE (TO BE REMOVED)
10'
TC 398.2
BC 397.7
6" FIRE WATER SERVICE
TC 398.1
BC 397.6
TC 397.5
BC 397.0
TC 397.8
BC 397.8
END CURB
(FLUSH)
6" SAN.
INV 396.0 (V.I.F.)
INSULATE SANITARY
PIPE AND ENCASE IN
CONCRETE TO MANHOLE
INV 393.7 (8" HDPE DRAIN AT SANITARY PIPE CROSSING - ENCASE IN CONCRETE)
INV 395.4 (6" PVC SANITARY AT DRAIN PIPE CROSSING - ENCASE IN CONCRETE)
FLUSH GRANITE CURB
Contract Date
Drawn by
Checked by
No. Description Date
Revisions & Notes
Code
Structural
MEP
Scale
Salamone & Associates, P.C.
116 North Plains Industrial Road Wallingford, CT 06492 P: 203 281 6895 F: 203 287 8728 W: salamoneassoc.com
Morrissey Engineering, LLC 58 Essex Street Deep River, CT 06417 P: 860 532 0312 W: morrisseyengineers.com
Sparc Fire Protection Engineering P: 203 391 6633, 212 392 5868 W: sparcfp.com
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G Issue Date
CIVIL
SLR International Corporation 99 Realty Drive Cheshire, CT 06037 P: 203 271 1773 W: slrconsulting.com
K E
N T
M E
M O
R
IA
L
LI
B R
A R
Y
N O
R
TH
M
AI
N S
TR
EE
T
GRADING &
UTILITIES
C-1.03 1"=20'
TDR
DSR
October 20, 2025
September 25, 2024
Se pt em be r 2 5, NOTES:
1. ALL UTILITY SERVICES ARE TO BE UNDERGROUND. THE EXACT LOCATION AND SIZE OF ELECTRIC, TELEPHONE, CABLE TELEVISION, SANITARY SEWER AND PUBLIC WATER ARE TO BE DETERMINED BY THE RESPECTIVE UTILITY COMPANIES.
2. ALL STORM PIPING SHALL BE HIGH DENSITY POLYETHYLENE PIPE (HDPE) UNLESS OTHERWISE NOTED.
3. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS INDICATE FINISHED GRADE.
4. ALL GRAVITY SANITARY SEWER PIPE SHALL BE SDR35 UNLESS OTHERWISE NOTED.
5. PROVIDE MINIMUM VERTICAL SEPARATION OF 18" BETWEEN WATER SERVICE AND SEWER SERVICE.
6. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ANY UTILITIES INCLUDING IRRIGATION PIPES PRIOR TO THE START OF
CONSTRUCTION.
7. ALL DIMENSIONS AND ELEVATIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER.
8. ALL CONSTRUCTION MATERIALS AND METHODS SHALL CONFORM TO THE TOWN OF KENT REQUIREMENTS AND TO THE APPLICABLE SECTIONS OF THE STATE OF CONNECTICUT DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROADS, BRIDGES, FACILITIES AND INCIDENTAL CONSTRUCTION, FORM 818 AND ADDENDUMS.
9. THE PLANS REQUIRE A CONTRACTOR'S WORKING KNOWLEDGE OF LOCAL, MUNICIPAL, WATER AUTHORITY, AND STATE CODES FOR UTILITY SYSTEMS. ANY CONFLICTS BETWEEN MATERIALS AND LOCATIONS SHOWN, AND LOCAL REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE EXECUTION OF WORK. THE ENGINEER WILL NOT BE HELD LIABLE FOR COSTS
INCURRED TO IMPLEMENT OR CORRECT WORK WHICH DOES NOT CONFORM TO LOCAL CODE.
10. COMPLIANCE WITH THE PERMIT CONDITIONS IS THE RESPONSIBILITY OF BOTH THE CONTRACTOR AND PERMITEE.
11. A MAXIMUM FINISHED SLOPE OF 5.0% SHALL BE PROVIDED FOR ALL WALKWAYS AND HARDSCAPE AREAS AND A MAXIMUM FINISHED SLOPE OF 2.0% SHALL BE PROVIDED FOR ALL CONCRETE LANDINGS, IN ACCORDANCE WITH ADA ACCESSIBILITY
STANDARDS.
12. A MINIMUM FINISHED SLOPE OF 1.0% SHALL BE PROVIDED IN ALL SITE AREAS TO ALLOW FOR SURFACE DRAINAGE.
13. ROOF DRAIN DOWNSPOUTS THAT ARE NOT CONNECTED TO ROOF DRAIN COLLECTOR PIPING SHALL DISCHARGE ONTO THE GROUND SURFACE WHICH HAS BEEN STABILIZED WITH CRUSHED STONE, GRAVEL OR A CONCRETE SPLASH PAD.
14. ALL WORK WITHIN THE CONNECTICUT DEPARTMENT OF TRANSPORTATION (CTDOT) ROADWAY RIGHT-OF-WAY REQUIRES THE
CONTRACTOR TO OBTAIN AN ENCROACHMENT PERMIT FROM CTDOT.
X X
X X
X
X X
X
CB
#28 NORTH MAIN STREET
BUILDING
#32 NORTH MAIN STREET
BUILDING
CONC.
CONC. BITUMINOUS SIDEWALK
CB
CB
CB
CB
CONCRETE
PATIO
SLATE
PATIO
S L
A T
E P
A T
IO
BIRD
BATH
B
IT
U M
IN
O
U S
S
ID
E W
A
LK CONCRETE STEP
B
IT
U M
IN
O
E
W A
LK
SLATE WALK
#30 NORTH MAIN STREET
BUILDING
CONC.
C O N C.
OIL
FILLER
B
IT
. W A
LK
CONC.
CONCRETE APRON
C O
N C
R E
T E
W A
L K
B I L C O
D O O R
GRAVEL P
ARKING A
REA
ED
G
E O F B
IT
U
M
IN
O U
S
G R
A V
R
K
E
A
AC-UNIT
DOOR SILL
EL.= 399.53'
FLOOR
EL.= 398.84'
DOOR SILL
EL.= 398.13'
FLOOR
EL.= 398.83'
DOOR SILL 1ST. FLR. EL.= 399.01'
DOOR SILL 2ND FLR. EL.= 411.18'
DOOR SILL
EL.= 398.92'
DOOR SILL
EL.= 399.1'
FLAG
POLE
E
CHARGE
STATION
PLT.
PLT.
PLT.
PLT.
PLANTING
CONC.
CONC.
RIM 396.06'
INV 393.10± (6")
INV 392.52± (15")
PLT.
R C
P
6" PV
C
E E
E
E
E
E
E
EXISTING
BUILDING
BUILDING
ADDITION
EXISTING
BUILDING
RAILROAD STREET (P
RIVATE ROAD)
NORTH MAIN STREET (RTE. 7)
LA
N
E S
TR
EET
SEDIMENT AND EROSION CONTROL MEASURES AS DEPICTED ON THESE PLANS AND DESCRIBED WITHIN THE SEDIMENT AND EROSION CONTROL NARRATIVE SHALL BE IMPLEMENTED AND MAINTAINED UNTIL PERMANENT COVER AND STABILIZATION IS ESTABLISHED. ALL SEDIMENT AND EROSION CONTROL MEASURES SHALL CONFORM TO THE "GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL, CONNECTICUT - 2024" AND IN ALL CASES BEST MANAGEMENT PRACTICES SHALL PREVAIL.
1. PURPOSE AND DESCRIPTION OF PROJECT
1.1. PROPOSED PARKING LOT AND SIDEWALK MODIFICATIONS
1.2. ESTIMATED AREA OF DISTURBANCE: ±0.46 ACRES
1.3. EARTHWORK SCHEDULE: EARTHWORK ACTIVITIES TO BEGIN IN SPRING 2026 AND WILL CONTINUE UNTIL SUBSTANTIAL SITE
WORK IS COMPLETED AND STABILIZED. COMPLETION OF CONSTRUCTION PLANNED FOR 2026.
2. IDENTIFICATION OF EROSION AND SEDIMENT CONTROL CONCERNS
2.1. CUTS AND FILLS ASSOCIATED WITH EXISTING DRIVEWAY AND SIDEWALKS.
3. IDENTIFICATION OF OTHER POSSIBLE PERMITS
3.1. TOWN OF KENT PLANNING & ZONING SITE PLAN PERMIT.
4. CONSERVATION PRACTICES INCORPORATED INTO THE PROJECT ARE AS FOLLOWS:
4.1. DETAILED CONSTRUCTION SEQUENCE - SEE TITLE SHEET
4.2. DETAILED SOIL EROSION AND SEDIMENT CONTROL PLAN.
5. CONTACT PERSON
5.1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SOIL AND EROSION CONTROLS.
SOIL EROSION AND SEDIMENT CONTROL NARRATIVE:
SHEET NOTES
1. SEE DETAIL SHEETS FOR EROSION CONTROL MAINTENANCE INTERVALS.
2. ALL DEWATERING WASTE WATERS SHALL BE DISCHARGED IN A MANNER WHICH MINIMIZES THE DISCOLORATION OF THE RECEIVING
WATERS.
3. THE SITE SHOULD BE KEPT CLEAN OF LOOSE DEBRIS, LITTER, AND BUILDING MATERIALS SUCH THAT NONE OF THE ABOVE ENTER
WATERS OR WETLANDS.
4. A COPY OF ALL PLANS AND REVISIONS, AND THE SEDIMENT AND EROSION CONTROL PLAN SHALL BE MAINTAINED ON-SITE AT ALL
TIMES DURING CONSTRUCTION.
5. CHIP AND DISPOSE OF ALL CLEARED MATERIAL IF NOT USED ONSITE FOR TEMPORARY EROSION CONTROLS.
6. ALL INLETS TO HAVE SILT SACK INLET PROTECTION UNTIL SITE IS PERMANENTLY STABILIZED.
10. ALL CATCH BASINS SHALL BE INSPECTED UPON PERMANENT REMOVAL OF INLET PROTECTION. ANY SEDIMENT WILL BE REMOVED.
11. ANY AREA, INCLUDING STOCKPILES, EXPOSED FOR MORE THAN ONE MONTH AND LESS THAN TWELVE MONTHS WILL BE STABILIZED
WITH VEGETATIVE COVER.
12. SEDIMENT AND EROSION CONTROL MEASURES AS DEPICTED ON THESE PLANS AND DESCRIBED WITHIN THE SEDIMENT AND EROSION CONTROL NARRATIVE SHALL BE IMPLEMENTED AND MAINTAINED UNTIL PERMANENT COVER AND STABILIZATION IS ESTABLISHED. ALL SEDIMENT AND EROSION CONTROL MEASURES SHALL CONFORM TO THE "CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL - 2024, AS AMENDED, AND IN ALL CASES BEST MANAGEMENT PRACTICES SHALL PREVAIL.
13. THE CONTRACTOR MUST MAINTAIN (REPAIR/REPLACE WHEN NECESSARY) THE EROSION CONTROLS UNTIL ALL DEVELOPMENT ACTIVITY
IS COMPLETED AND ALL DISTURBED AREAS ARE PERMANENTLY STABILIZED.
EROSION CONTROL LEGEND
CE
IP INLET PROTECTION
CONSTRUCTION
ENTRANCE
(50 L.F. MIN.)
GSF SEDIMENT FILTER FENCE
SOIL STOCKPILE AREASTK
Contract Date
Drawn by
Checked by
No. Description Date
Revisions & Notes
Code
Structural
MEP
Scale
Salamone & Associates, P.C.
116 North Plains Industrial Road Wallingford, CT 06492 P: 203 281 6895 F: 203 287 8728 W: salamoneassoc.com
Morrissey Engineering, LLC 58 Essex Street Deep River, CT 06417 P: 860 532 0312 W: morrisseyengineers.com
Sparc Fire Protection Engineering P: 203 391 6633, 212 392 5868 W: sparcfp.com
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G Issue Date
CIVIL
SLR International Corporation 99 Realty Drive Cheshire, CT 06037 P: 203 271 1773 W: slrconsulting.com
K E
N T
M E
M O
R
IA
L
LI
B R
A R
Y
N O
R
TH
M
AI
N S
TR
EE
T
SEDIMENT &
EROSION
CONTROL
PLAN
C-1.04 1"=20'
TDR
DSR
October 20, 2025
September 25, 2024
Se pt em be r 2 5, GENERAL:
THESE GUIDELINES SHALL APPLY TO ALL WORK CONSISTING OF ANY AND ALL TEMPORARY
AND/OR PERMANENT MEASURES TO CONTROL WATER POLLUTION AND SOIL EROSION, AS
MAY BE REQUIRED, DURING THE CONSTRUCTION OF THE PROJECT.
IN GENERAL, ALL CONSTRUCTION ACTIVITIES SHALL PROCEED IN SUCH A MANNER SO AS
NOT TO POLLUTE ANY WETLANDS, WATERCOURSE, WATER BODY, AND CONDUIT CARRYING
WATER, ETC. THE CONTRACTOR SHALL LIMIT, INSOFAR AS POSSIBLE, THE SURFACE AREA
OF EARTH MATERIALS EXPOSED BY CONSTRUCTION METHODS AND IMMEDIATELY PROVIDE
PERMANENT AND TEMPORARY POLLUTION CONTROL MEASURES TO PREVENT
CONTAMINATION OF ADJACENT WETLANDS, WATERCOURSES, AND WATER BODIES, AND TO
PREVENT, INSOFAR AS POSSIBLE, EROSION ON THE SITE.
LAND GRADING:
THE RESHAPING OF THE GROUND SURFACE BY EXCAVATION AND FILLING OR A
COMBINATION OF BOTH, TO OBTAIN PLANNED GRADES, SHALL PROCEED IN ACCORDANCE
WITH THE FOLLOWING CRITERIA:
a. THE CUT FACE OF EARTH EXCAVATION SHALL NOT BE STEEPER THAN TWO HORIZONTAL
TO ONE VERTICAL (2:1).
b. THE PERMANENT EXPOSED FACES OF FILLS SHALL NOT BE STEEPER THAN TWO
HORIZONTAL TO ONE VERTICAL (2:1).
c. THE CUT FACE OF ROCK EXCAVATION SHALL NOT BE STEEPER THAN ONE HORIZONTAL
TO TWO VERTICAL (1:2).
d. PROVISIONS SHOULD BE INCLUDED TO CONVEY SURFACE WATER SAFELY TO STORM
DRAINS TO PREVENT SURFACE RUNOFF FROM DAMAGING CUT FACES AND FILL SLOPES.
e. NO FILL SHOULD BE PLACED WHERE IT WILL SLIDE OR WASH UPON THE INTO
ADJACENT WETLANDS, WATERCOURSES, OR WATER BODIES.
f. PRIOR TO ANY RE-GRADING, A STABILIZED CONSTRUCTION ENTRANCE SHALL BE
PLACED AT THE ENTRANCE TO THE WORK AREA IN ORDER TO REDUCE MUD AND OTHER
SEDIMENTS FROM LEAVING THE SITE.
TOPSOILING:
TOPSOIL SHALL BE SPREAD OVER ALL EXPOSED AREAS IN ORDER TO PROVIDE A SOIL
MEDIUM HAVING FAVORABLE CHARACTERISTICS FOR THE ESTABLISHMENT, GROWTH, AND
MAINTENANCE OF VEGETATION.
UPON ATTAINING FINAL SUBGRADES, SCARIFY SURFACE TO PROVIDE A GOOD BOND WITH
TOPSOIL.
REMOVE ALL LARGE STONES, TREE LIMBS, ROOTS AND CONSTRUCTION DEBRIS.
APPLY LIME ACCORDING TO SOIL TEST OR AT THE RATE OF TWO (2) TONS PER ACRE.
MATERIAL:
1. TOPSOIL SHOULD HAVE PHYSICAL, CHEMICAL, AND BIOLOGICAL CHARACTERISTICS
FAVORABLE TO THE GROWTH OF PLANTS.
2. TOPSOIL SHOULD HAVE A SANDY OR LOAMY TEXTURE.
3. TOPSOIL SHOULD BE RELATIVELY FREE OF SUBSOIL MATERIAL AND MUST BE FREE OF
STONES (OVER 1" IN DIAMETER), LUMPS OF SOIL, ROOTS, TREE LIMBS, TRASH, OR
CONSTRUCTION DEBRIS. IT SHOULD BE FREE OF ROOTS OR RHIZOMES SUCH AS
THISTLE, NUTGRASS, AND QUACKGRASS.
4. AN ORGANIC MATTER CONTENT OF SIX PERCENT (6%) IS REQUIRED. AVOID LIGHT
COLORED SUBSOIL MATERIAL.
5. SOLUBLE SALT CONTENT OF OVER 500 PARTS PER MILLION (PPM) IS LESS SUITABLE.
AVOID TIDAL MARSH SOILS BECAUSE OF HIGH SALT CONTENT AND SULFUR ACIDITY.
6. THE pH SHOULD BE MORE THAN 6.0. IF LESS, ADD LIME TO INCREASE pH TO AN
ACCEPTABLE LEVEL.
APPLICATION:
1. AVOID SPREADING WHEN TOPSOIL IS WET OR FROZEN.
2. SPREAD TOPSOIL UNIFORMLY TO A DEPTH OF AT LEAST SIX INCHES (6"), OR TO THE
DEPTH SHOWN ON THE PLANS.
TEMPORARY VEGETATIVE COVER:
TEMPORARY VEGETATIVE COVER SHALL BE ESTABLISHED ON ALL UNPROTECTED AREAS
THAT PRODUCE SEDIMENT, AREAS WHERE FINAL GRADING HAS BEEN COMPLETED, AND
AREAS WHERE THE ESTIMATED PERIOD OF BARE SOIL EXPOSURE IS LESS THAN 12
MONTHS. TEMPORARY VEGETATIVE COVER SHALL BE APPLIED IF AREAS WILL NOT BE
PERMANENTLY SEEDED BY SEPTEMBER 1.
SITE PREPARATION:
1. INSTALL REQUIRED SURFACE WATER CONTROL MEASURES.
2. REMOVE LOOSE ROCK, STONE, AND CONSTRUCTION DEBRIS FROM AREA.
3. APPLY LIME ACCORDING TO SOIL TEST OR AT A RATE OF ONE (1) TON OF GROUND
DOLOMITIC LIMESTONE PER ACRE (5 LBS. PER 100 SQ. FT.).
4. APPLY FERTILIZER ACCORDING TO SOIL TEST OR AT THE RATE OF 300 LBS. OF 10-10-10
PER ACRE (7 LBS. PER 1,000 SQ. FT.) AND SECOND APPLICATION OF 200 LBS. OF
10-10-10- (5 LBS. PER 1,000 SQ. FT.) WHEN GRASS IS FOUR INCHES (4") TO SIX
INCHES (6") HIGH. APPLY ONLY WHEN GRASS IS DRY.
5. UNLESS HYDROSEEDED, WORK IN LIME AND FERTILIZER TO A DEPTH OF FOUR (4")
INCHES USING A DISK OR ANY SUITABLE EQUIPMENT.
6. TILLAGE SHOULD ACHIEVE A REASONABLY UNIFORM LOOSE SEEDBED. WORK ON
CONTOUR IF SITE IS SLOPING.
ESTABLISHMENT:
1. APPLY SEED UNIFORMLY ACCORDING TO THE RATE INDICATED BY BROADCASTING,
DRILLING, OR HYDRAULIC APPLICATION.
2. UNLESS HYDROSEEDED, COVER RYEGRASS SEEDS WITH NOT MORE THAN 1/4 INCH OF
SOIL USING SUITABLE EQUIPMENT.
3. MULCH IMMEDIATELY AFTER SEEDING IF REQUIRED. (REFER TO TEMPORARY OR
PERMANENT VEGETATIVE COVER REQUIREMENTS.) APPLY STRAW MULCH AND ANCHOR
TO SLOPES GREATER THAN 3% OR WHERE CONCENTRATED FLOW WILL OCCUR.
PERMANENT VEGETATIVE COVER:
PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED AS VARIOUS SECTIONS OF THE
PROJECT ARE COMPLETED IN ORDER TO STABILIZE THE SOIL, REDUCE DOWNSTREAM
DAMAGE FROM SEDIMENT AND RUNOFF, AND TO ENHANCE THE AESTHETIC NATURE OF THE
SITE. IT WILL BE APPLIED TO ALL CONSTRUCTION AREAS SUBJECT TO EROSION WHERE
FINAL GRADING HAS BEEN COMPLETED AND A PERMANENT COVER IS NEEDED.
SITE PREPARATION:
1. INSTALL REQUIRED SURFACE WATER CONTROL MEASURES.
2. REMOVE LOOSE ROCK, STONE, AND CONSTRUCTION DEBRIS FROM AREA.
3. PERFORM ALL PLANTING OPERATIONS PARALLEL TO THE CONTOURS OF THE SLOPE.
4. APPLY TOPSOIL AS INDICATED ELSEWHERE HEREIN.
5. APPLY FERTILIZER ACCORDING TO SOIL TEST OR:
· SPRING SEEDING: WORK DEEPLY IN SOIL, BEFORE SEEDING, 300 LBS. OF 10-10-10
FERTILIZER PER ACRE (7 LBS. PER 1,000 SQ. FT.); THEN SIX (6) TO EIGHT (8)
WEEKS LATER, APPLY ON THE SURFACE AN ADDITIONAL 300LBS. OF 10-10-10
FERTILIZER PER ACRE. AFTER SEPTEMBER 1, TEMPORARY VEGETATIVE COVER
SHALL BE APPLIED.
· FALL SEEDING: WORK DEEPLY IN SOIL, BEFORE SEEDING, 600 LBS. OF 10-10-10
FERTILIZER PER ACRE (14 LBS. PER 1,000 SQ. FT.).
EROSION CHECKS:
GENERAL:
TEMPORARY PERVIOUS BARRIERS USING BALES OF STRAW, HELD IN PLACE WITH STAKES
DRIVEN THROUGH THE BALES AND INTO THE GROUND OR GEOTEXTILE FABRIC FASTENED
TO A FENCE POST AND BURIED INTO THE GROUND, SHALL BE INSTALLED AND MAINTAINED
AS REQUIRED TO CHECK EROSION AND REDUCE SEDIMENTATION.
CONSTRUCTION:
BALES SHOULD BE PLACED IN A ROW WITH ENDS TIGHTLY ABUTTING THE ADJACENT BALES.
EACH BALE SHALL BE EMBEDDED INTO THE SOIL A MINIMUM OF FOUR (4") INCHES.
BALES SHALL BE SECURELY ANCHORED IN PLACE BY WOOD STAKES OR REINFORCEMENT
BARS DRIVEN THROUGH THE BALES AND INTO THE GROUND. THE FIRST STAKE IN EACH
BALE SHALL BE ANGLED TOWARD THE PREVIOUSLY LAID BALE TO FORCE BALES TOGETHER.
GEOTEXTILE FABRIC SHALL BE SECURELY ANCHORED AT THE TOP OF A THREE FOOT (3')
HIGH FENCE AND BURIED A MINIMUM OF FOUR INCHES (4") TO THE SOIL. SEAMS BETWEEN
SECTIONS OF FILTER FABRIC SHALL OVERLAP MINIMUM OF TWO FEET (2').
INSTALLATION AND MAINTENANCE:
1. BALED STRAW EROSION BARRIERS SHALL BE INSTALLED AT ALL STORM SEWER INLETS.
2. BALED STRAW EROSION BARRIERS AND GEOTEXTILE FENCE SHALL BE INSTALLED AT
THE LOCATION INDICATED ON THE PLAN AND IN ADDITIONAL AREAS AS MAY BE
DEEMED APPROPRIATE DURING CONSTRUCTION.
3. ALL EROSION CHECKS SHALL BE MAINTAINED UNTIL ADJACENT AREAS ARE STABILIZED.
4. INSPECTION SHALL BE FREQUENT (AT MINIMUM BI-MONTHLY AND AFTER RAINFALL
EVENTS GREATER THAN ONE HALF INCH) AND REPAIR OR REPLACEMENT SHALL BE
MADE PROMPTLY AS NEEDED.
5. EROSION CHECKS SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFULNESS
SO AS NOT TO BLOCK OR IMPEDE STORM WATER FLOW OR DRAINAGE.
TEMPORARY STABILIZATION FOR
WINTER CONDITIONS:
ANY SIGNIFICANT AREAS OF EXPOSED SOIL WHICH HAVE BEEN DISTURBED AFTER
OCTOBER 15TH SHALL BE TEMPORARILY STABILIZED BY ONE OF THE FOLLOWING METHODS
UNTIL SUCH TIME THAT PERMANENT STABILIZATION MEASURES AND SEEDING CAN BE
APPLIED, TYPICALLY AFTER MAY 15TH.
1. INSTALLATION OF AN ANCHORED EROSION CONTROL BLANKET. EROSION CONTROL
BLANKETS SHOULD NOT BE INSTALLED ON SNOW OF GREATER THAN ONE INCH IN
DEPTH OR ON FROZEN GROUND.
2. APPLICATION OF STRAW MULCH AT A RATE OF FOUR (4) TONS PER ACRE.
3. APPLICATION OF WOOD CHIP MULCH AT A MINIMUM DEPTH OF THREE INCHES (3").
WOOD CHIP MULCH SHOULD NOT BE USED ON SLOPES GREATER THAN 2:1 (H:V). ALL
WOOD CHIP MULCH SHALL BE REMOVED PRIOR TO RESUMING SITE GRADING.
VEGETATIVE COVER SELECTION &
MULCHING:
TEMPORARY VEGETATIVE COVER:
PERENNIAL RYEGRASS 3 LBS./1,000 SQ.FT. (IOLUIUM PERENNE)
PERMANENT VEGETATIVE COVER:
1. TURFGRASS MIX OR EQUAL:
RECOMMENDED APPLICATION RATE: 1 POUND PER 1,750 SF
SEED MIX SPECIES: CREEPING RED FESCUE (Festuca rubra var. rubra (endophyte enchanced)) - 15%, PERENNIAL RYEGRASS (Lolium multiflorum) - 15%, KENTUCKY BLUEGRASS (Poa pratensis "KenBlue') - 35%, CHEWINGS FESCUE (Festuca rubra var.
commutate 'Tiffany') - 15%.
TEMPORARY MULCHING: STRAW AT 70-90 LBS./1,000 SQ.FT. (TEMPORARY
VEGETATIVE AREAS) WOOD FIBER IN HYDROMULCH SLURRY 25-50 LBS./1,000 SQ. FT.
2. WITHIN 100-FOOT REGULATED UPLAND AREAS FROM WETLANDS:
RECOMMENDED APPLICATION RATE: 1 POUND PER 1,250 SF
SEED MIX SPECIES: NEW ENGLAND EROSION CONTROL/RESTORATION MIX (FOR
MOIST SITES) OR 1 POUND PER 1,750 SF NEW ENGLAND CONSERVATION/WILDLIFE
MIX.
ESTABLISHMENT:
1. SMOOTH AND FIRM SEEDBED WITH CULTIPACKER OR OTHER SIMILAR EQUIPMENT
PRIOR TO SEEDING (EXCEPT WHEN HYDROSEEDING).
2. SELECT ADAPTED SEED MIXTURE FOR THE SPECIFIC SITUATION. NOTE RATES AND THE
SEEDING DATES (REFER TO TEMPORARY OR PERMANENT VEGETATIVE COVER
REQUIREMENTS).
3. APPLY SEED UNIFORMLY ACCORDING TO RATE INDICATED, BY BROADCASTING,
DRILLING, OR HYDRAULIC APPLICATION.
4. COVER GRASS AND LEGUME SEED WITH NOT MORE THAN 1/4 INCH OF SOIL WITH
SUITABLE EQUIPMENT (EXCEPT WHEN HYDROSEEDING).
5. MULCH IMMEDIATELY AFTER SEEDING, IF REQUIRED, ACCORDING TO TEMPORARY
MULCHING SPECIFICATIONS. (REFER TO TEMPORARY OR PERMANENT VEGETATIVE
COVER REQUIREMENTS).
6. USE PROPER INOCULANT ON ALL LEGUME SEEDINGS, USE FOUR (4) TIMES NORMAL
RATES WHEN HYDROSEEDING.
7. THE USE OF SOD IS AN ACCEPTABLE ALTERNATIVE WHERE THERE IS A HEAVY
CONCENTRATION OF WATER AND IN CRITICAL AREAS WHERE IT IS IMPORTANT TO GET
A QUICK VEGETATIVE COVER TO PREVENT EROSION.
MAINTENANCE:
1. TEST FOR SOIL ACIDITY EVERY THREE (3) YEARS AND LIME AS REQUIRED.
2. ON SITES WHERE GRASSES PREDOMINATE, BROADCAST ANNUALLY 500 POUNDS OF
10-10-10 FERTILIZER PER ACRE (12 LBS. PER 1,000 SQ. FT.) OR AS NEEDED
ACCORDING TO ANNUAL SOIL TESTS.
3. ON SITES WHERE LEGUMES PREDOMINATE, BROADCAST EVERY THREE (3)YEARS OR AS
INDICATED BY SOIL TEST 300 POUNDS OF 0-20-20 OR EQUIVALENT PER ACRE (8 LBS
PER 1,000 SQ. FT.).
SEDIMENT & EROSION CONTROL SPECIFICATIONS
SLOPE OR LESS2
STABILIZE ENTIRE PILE
WITH VEGETATION OR COVER
MIN. SLOPEMIN. SLOPE
OR COVERED.
INSTALLATION NOTES
2. MAXIMUM SLOPE OF STOCKPILE SHALL BE 1:2.
STRAWBALES OR SILTFENCE
1. AREA CHOSEN FOR STOCKPILING OPERATIONS SHALL BE DRY AND STABLE.
3. UPON COMPLETION OF SOIL STOCKPILING, EACH PILE SHALL BE SURROUNDED
WITH EITHER SILT FENCING OR STRAWBALES, THEN STABILIZED WITH VEGETATION
STOCKPILE PROTECTION (STK)
NOT TO SCALE
4. ALL STOCK PILES TO REMAIN IN PLACE FOR MORE THAN 30 CONSECUTIVE DAYS SHALL
BE TEMPORARILY SEEDED.
1" REBAR FOR BAG
REMOVAL FROM INLET
SILTSACK
CONDITIONS
FRAME FOR TRAFFIC
OPTIONAL METAL HANGING
DUMP STRAP
DUMP STRAP
EXPANSION RESTRAINT
(1/4" NYLON ROPE, 2"
FLAT WASHERS)
2 EACH DUMP
STRAPS
INLET PROTECTION (IP)
NOT TO SCALE
INSTALLATION DETAIL BAG DETAIL
EROSION CONTROL MAINTENANCE INTERVALS
EROSION CONTROL
MEASURE CONTROL OBJECTIVE INSPECTION/MAINTENANCE FAILURE INDICATORS REMOVAL
SILT FENCE (SF)
(RELATED: IP, STK)
- INTERCEPT, AND…