1-11-4-25-MAIN LIBRARY-01 INSP - 30-32 NORTH MAIN STREET KENT CT.pdf.crdownload

CRDOWNLOAD file 8 MB Posted

Attached to
Kent Memorial Library Expansion
Solicitation number
33247
Issued by
Litchfield County, Connecticut

About this file

This is a Limited and Directed Pre-Renovation Asbestos Survey Report prepared by Reliance Environmental, LLC for Kent Memorial Library, a Connecticut state and local property located at 30-32 North Main Street, Kent, CT. The survey was conducted on October 27, 2025, by a State of Connecticut licensed asbestos inspector to identify asbestos-containing materials (ACMs) prior to facility renovation. A total of 45 bulk samples were collected from the two-building property (Building #30, the Firehouse, and Building #32, the Library) and analyzed using Polarized Light Microscopy (PLM) according to EPA 600/R-93/116 protocol. The survey identified four locations containing asbestos at concentrations greater than or equal to 1.0 percent: vermiculite insulation in the attic of Building #30 (approximately 2,000 square feet), mastic in flooring layers on the second floor front room of Building #30 (approximately 1,500 square feet), window glazing on the exterior of Building #30 (35 windows), and 9" x 9" floor tiles on the first-floor stairs of Building #32 (approximately 100 square feet). The report notes that removal of all identified ACMs must be performed by a Connecticut State licensed asbestos abatement contractor and that abatement contractors should verify quantities and removal difficulty prior to submitting cost proposals.

The survey was performed for Ms. Sarah Marshall, Director of Kent Memorial Library, with the report prepared by Vidya N. Trivedi of Reliance Environmental, LLC, who holds current Connecticut Department of Public Health Asbestos Consultant-Project Designer certification (Certificate No. 000017, valid through March 31, 2026). The laboratory analysis was completed by Asbestos Identification Laboratory in Woburn, Massachusetts, which holds multiple state certifications and NVLAP accreditation. The report specifically notes that additional suspect materials may exist behind fixed walls, under flooring, or above ceilings, and if any such materials are discovered during renovation, all activities must cease pending sampling by a licensed inspector. The EPA recommends that vermiculite insulation not be disturbed and that any removal be performed by trained, accredited abatement contractors independent from the assessment firm to avoid conflicts of interest.

Text of this file

Reliance Environmental, LLC Asbestos, Lead, Mold, Phase 1-3, Hazmat, Soil, Indoor Air & Ground Water Quality Specialists

Limited & Directed Pre-renovation Asbestos Survey Report For Kent Memorial Library Located at

30-32 North Main Street Kent, CT 06757

Prepared for:

Ms. Sarah Marshall, Director Kent Memorial Library 30 North Main Street Danbury, CT 06810

(860) 927-3761 | smarshall@biblio.org

November 04, 2025

Reliance Project # 25-LIBRARY-01

140 Captain Thomas Blvd • Suite 201 • West Haven • CT 06516

(203) 553-9070 • Fax (203) 553-9069 • vidyatrivedi2002@yahoo.com

Reliance Environmental, LLC - S Kent Memorial Library.

Reliance #25-LIBRARY-01 1 30-32 North Main Street, Kent, CT

TABLE OF CONTENTS

Section Page

I. PROJECT NARRATIVE

OVERVIEW

SUMMARY OF RESULTS

II. SAMPLE LOG AND RESULTS TABLE

BULK SAMPLES COLLECTED ON 10-27-25

III. CHAIN OF CUSTODY & LAB ANALYSIS SHEETS FOR ASBESTOS

IV. STATE OF CT ASBESTOS INSPECTOR LICENSE

Reliance #25-LIBRARY-01 2 30-32 North Main Street, Kent, CT

I. PROJECT NARRATIVE

Overview

On October 27 of 2025, a State of Connecticut licensed asbestos inspector from Reliance Environmental, LLC performed a limited and directed pre-renovation asbestos survey for Kent Memorial Library of a property located at 30-32 North Main Street, Kent, CT. The purpose of this inspection was to determine the presence of asbestos in suspect building materials so that all issues related to asbestos containing materials could be addressed prior to renovation of the referenced facility.

Samples were collected according to 40 CFR Part 763.86 and 29 CFR Part 1926.1101 and analyzed using Polarized Light Microscopy (PLM) using EPA 600/R-93/116 protocol.

A total of Forty-Five (45) bulk samples were collected from the above noted facility.

Please refer to table in Section II for various types of building materials sampled during this asbestos survey.

Summary of Results

The Asbestos Identification Lab analyzed the bulk samples. Section III presents the complete list of analytical result for samples collected.

“MATERIALS FOUND TO CONTAIN GREATER THAN OR EQUAL TO 1.0 PERCENT ASBESTOS

(CALLED ASBESTOS CONTAINING MATRERIALS OR “ACMs”) DURING THE ASBESTOS

SURVEY”

Note: SF-Square Feet PACM-Presumed Asbestos Containing Materials Location Asbestos Containing Materials (ACM) Approximate

Quantity Attic – Firehouse (Building

#30) Vermiculite (PACM) ~ 2,000 SF

Second Floor – Front Room, Firehouse (Building #30)

Mastic (Third Layer) (Remove all layers of flooring up to substrate) ~1,500 SF

Exterior (Building #30) Glazing 35 Each (Windows)

First Floor – Stairs, Library (Building #32) 9” x 9” Floor Tiles ~ 100 SF

Specific Notes:

1. This inspection has been performed based on standard industry practices. The possibility however exists that suspect asbestos-containing materials may be located behind fixed walls, under fixed Flooring or above fixed ceilings. If additional materials are seen or become accessible, all activities shall cease and the materials shall be sampled by a licensed inspector to determine the presence of asbestos.

Reliance #25-LIBRARY-01 3 30-32 North Main Street, Kent, CT

2. Please note that certain OSHA, 29 CFR 1926.1101 regulations apply if materials containing less than 1% asbestos are disturbed.

3. The abatement contractor shall verify the quantities of asbestos containing materials indicated in the table above and degree of difficulty that will be encountered during removal prior to submitting quotes.

4. Removal of all asbestos containing materials listed in the table above shall be removed by a CT State licensed asbestos abatement contractor.

Reliance #25-LIBRARY-01 4 30-32 North Main Street, Kent, CT

II. SAMPLE LOG AND RESULTS TABLE

BULK SAMPLES COLLECTED ON 10-27-25

NAD = No Asbestos Detected NA = Not Analyzed SP/NA = Stop Positive/Not Analyzed Sample

ID

Number

Location Material Sampled Percent Asbestos

1 First Floor – Passage, Library (Building #32) Cove Base NAD

2 First Floor – Passage, Library (Building #32) Cove Base NAD

3 First Floor – Passage, Library (Building #32) Glue NAD

4 First Floor – Passage, Library (Building #32) Glue NAD

5 First Floor – Passage, Library (Building #32) Carpet Glue NAD

6 First Floor – Passage, Library (Building #32) Carpet Glue NAD

7 First Floor – Stairs Landing, Library (Building #32) Flooring Materials NAD

8 First Floor – Stairs Landing, Library (Building #32) Flooring Materials NAD

9 First Floor – Stairs Landing, Library (Building #32) Glue NAD

10 First Floor – Stairs Landing, Library (Building #32) Glue NAD

11 First Floor – Stairs, Library (Building #32) 9” x 9” Floor Tiles 2

12 First Floor – Stairs, Library (Building #32) 9” x 9” Floor Tiles SP/NA

13 First Floor – Stairs, Library (Building #32) Glue NAD

14 First Floor – Stairs, Library (Building #32) Glue NAD

15 Second Floor – Kitchen, Firehouse (Building #30) Wall Board NAD

16 Second Floor – Room by Kitchen, Firehouse (Building #30) Wall Board NAD

17 Second Floor – Front Room, Firehouse (Building #30) Joint Compound NAD

18 Second Floor – Front Room, Firehouse (Building #30) Joint Compound NAD

19 Second Floor – Front Room, Firehouse (Building #30) Textured Ceiling NAD

20 Second Floor – Front Room, Firehouse (Building #30) Textured Ceiling NAD

21 Second Floor – Front Room, Firehouse (Building #30) Textured Ceiling NAD

22 Second Floor – Front Room, Firehouse (Building #30) Carpet Glue (First Layer) SP/NA

23 Second Floor – Front Room, Firehouse (Building #30) Floor Materials (Second Layer) SP/NA

Reliance #25-LIBRARY-01 5 30-32 North Main Street, Kent, CT

NAD = No Asbestos Detected NA = Not Analyzed SP/NA = Stop Positive/Not Analyzed Sample

ID

Number

Location Material Sampled Percent Asbestos

24 Second Floor – Front Room, Firehouse (Building #30) Mastic (Third Layer) 5

25 Second Floor – Room by Kitchen, Firehouse (Building #30)

Carpet Glue (First Layer) SP/NA

26 Second Floor – Room by Kitchen, Firehouse (Building #30)

Floor Materials (Second Layer) SP/NA

27 Second Floor – Room by Kitchen, Firehouse (Building #30)

Mastic (Third Layer) SP/NA

28 Second Floor – Kitchen, Firehouse (Building #30) Formica Glue NAD

29 Second Floor – Kitchen, Firehouse (Building #30) Sink Under Coating NAD

30 Second Floor – Kitchen, Firehouse (Building #30) Cove Base NAD

31 Second Floor – Kitchen, Firehouse (Building #30) Glue NAD

32 Second Floor – Kitchen, Firehouse (Building #30) 1’x1’ Floor Tiles NAD

33 Second Floor – Kitchen, Firehouse (Building #30) 1’x1’ Floor Tiles NAD

34 Second Floor – Kitchen, Firehouse (Building #30) Mastic NAD

35 Second Floor – Kitchen, Firehouse (Building #30) Mastic NAD

36 First Floor – Bathroom, Firehouse (Building #30) Cove Base NAD

37 First Floor – Bathroom, Firehouse (Building #30) Glue NAD

38 First Floor – Bathroom, Firehouse (Building #30) 1’x1’ Floor Tiles NAD

39 First Floor – Bathroom, Firehouse (Building #30) 1’x1’ Floor Tiles NAD

40 First Floor – Bathroom, Firehouse (Building #30) Glue NAD

41 First Floor – Bathroom, Firehouse (Building #30) Glue NAD

42 First Floor – Rear Room, Firehouse (Building #30) Brick Mortar NAD

43 First Floor – Firehouse (Building #30) Breeching Grout NAD

44 Exterior (Building #30) Window Glazing 2

45 Exterior (Building #30) Window Glazing SP/NA

Reliance #25-LIBRARY-01 6 30-32 North Main Street, Kent, CT

III. CHAIN OF CUSTODY & LAB ANALYSIS SHEETS FOR ASBESTOS

Asbestos Identification Laboratory.

165 New Boston St., Ste 227

Woburn, MA 01801 781-932-9600

Web: www.asbestosidentificationlab.com Email:

mikemanning@asbestosidentificationlab.com

Batch: 144513

Dear Vidya N. Trivedi, Thank you Vidya N. Trivedi for your business.

Michael Manning Owner/Director

Asbestos Identification Laboratory has completed the analysis of the samples from your office for the above referenced project.

The Analysis Method is BULK PLM ANALYSIS, EPA/600/R-93/116The information and analysis contained in this report have been generated using the EPA /600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. Materials or products that contain more than 1% of any kind or combination of asbestos are considered an asbestos containing building material as determined by the EPA. This Polarized Light Microscope (PLM) technique may be performed either by visual estimation or point counting. Point counting provides a determination of the area percentage of asbestos in a sample. If the asbestos is estimated to be less than 10% by visual estimation of friable material, the determination may be repeated using the point counting technique. The results of the point counting supersede visual PLM results. Results in this report only relate to the items tested. This report may not be used by the customer to claim product endorsement by NVLAP or any other U.S.

Government Agency.

The EPA recommends you should assume vermiculite contains asbestos and not to disturb it. Airborne asbestos fibers present a health risk through inhalation, so the first step is to not disturb the material, which could release fibers into the air. If you disturb the insulation, you may inhale some asbestos fibers. The degree of health risk depends on how much and how often this occurred. If you choose to remove the vermiculite insulation, this work should be done by a trained and accredited asbestos abatement contractor that is separate and independent from the company that performed the assessment of the vermiculite insulation to avoid any conflict of interest. Link: "https://www.epa.gov/asbestos/my-attic-has-vermiculite-insulation-it-am-i-risk-should-i-take-it-outld I take it out? | US EPA"

Vidya N. Trivedi Reliance Environmental, LLC 11 Old Farm Road Woodbridge, CT 06525

Project Information

30-32 North Main St., Kent, CT

Method: BULK PLM ANALYSIS, EPA/600/R-93/116

• NVLAP Lab Code: 200919-0

• Massachusetts Certification License: AA000208

• State of Connecticut, Department of Public Health Approved Environmental Laboratory Registration Number: PH-0142

• State of Maine, Department of Environmental Protection Asbestos Analytical Laboratory License Number: LB-0078(Bulk) LA-0087(Air)

• State of Rhode Island and Providence Plantations. Department of Health Certification: AAL-121

• State of Vermont, Department of Health Environmental Health License AL934461

Laboratory results represent the analysis of samples as submitted by the customer. Information regarding sample location, description, area, volume, etc., was provided by the customer. Information provided by the customer can affect the validity of results. Asbestos Identification Laboratory is not responsible for sample collection activities or analytical method limitations.

Unless notified in writing to return samples, Asbestos Identification Laboratory discards customer samples after 30 days.

Samples containing subsamples or layers will be analyzed separately when applicable. Reports are kept at Asbestos Identification Laboratory for three years. All customer information will be maintained in confidentiality. This report shall not be reproduced, except in full, without the written consent of Asbestos Identification Laboratory.

Vidya N. Trivedi

11 Old Farm Road Woodbridge, CT 06525

Project Information

30-32 North Main St., Kent, CT

Method: BULK PLM ANALYSIS, EPA/600/R-93/116

Asbestos %Material Color Non-Asbestos %LocationFieldID

LabID green Non-Fibrous 100

1630721

1 1st Fl Passage, Library (Bldg #32)

Cove Base None Detected green Non-Fibrous 100

1630722

2 1st Fl Passage, Library (Bldg #32)

Cove Base None Detected gray Non-Fibrous 100

1630723

3 1st Fl Passage, Library (Bldg #32)

Glue None Detected tan Non-Fibrous 100

1630724

4 1st Fl Passage, Library (Bldg #32)

Glue None Detected tan Non-Fibrous 100

1630725

5 1st Fl Passage, Library (Bldg #32)

Carpet Glue None Detected tan Non-Fibrous 100

1630726

6 1st Fl Passage, Library (Bldg #32)

Carpet Glue None Detected blue Non-Fibrous 100

1630727

7 1st Fl Stairs Landing Library (Bldg #32)

Flooring Material None Detected blue Non-Fibrous 100

1630728

8 1st Fl Stairs Landing Library (Bldg #32)

Flooring Material None Detected tan Non-Fibrous 100

1630729

9 1st Fl Stairs Landing Library (Bldg #32)

Glue None Detected tan Non-Fibrous 100

1630730

10 1st Fl Stairs Landing Library (Bldg #32)

Glue None Detected

Detected Chrysotile 2 red Non-Fibrous 98

1630731

11 1st Fl Stairs, Library (Bldg #32)

9"x9" Floor Tiles

1630732

12 1st Fl Stairs, Library (Bldg #32)

9"x9" Floor Tiles Not Analyzed tan Non-Fibrous 100

1630733

13 1st Fl Stairs, Library (Bldg #32)

Glue None Detected tan Non-Fibrous 100

1630734

14 1st Fl Stairs, Library (Bldg #32)

Glue None Detected gray Cellulose 10 Non-Fibrous 90

1630735

15 2nd Fl Kitchen, Firehouse (Bldg #30)

Wallboard None Detected gray Cellulose 10 Non-Fibrous 90

1630736

16 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Wallboard None Detected

Sampled: Received: October 31, 2025October 29, 2025 Analyzed:October 27, 2025

Analyzed by: 144513Batch:

Saturday 01 November

11 Old Farm Road Woodbridge, CT 06525

Project Information

30-32 North Main St., Kent, CT

Method: BULK PLM ANALYSIS, EPA/600/R-93/116

Asbestos %Material Color Non-Asbestos %LocationFieldID

LabID white Non-Fibrous 100

1630737

17 2nd Fl Front Room, Firehouse (Bldg #30)

Joint Compound None Detected white Non-Fibrous 100

1630738

18 2nd Fl Front Room, Firehouse (Bldg #30)

Joint Compound None Detected white Non-Fibrous 100

1630739

19 2nd Fl Front Rm, Firehouse (Bldg #30)

Textured Ceiling None Detected white Non-Fibrous 100

1630740

20 2nd Fl Front Rm, Firehouse (Bldg #30)

Textured Ceiling None Detected white Non-Fibrous 100

1630741

21 2nd Fl Front Rm, Firehouse (Bldg #30)

Textured Ceiling None Detected

1630742

22 2nd Fl Front Rm, Firehouse (Bldg #30)

Carpet Glue 1st Layer Not Analyzed

1630743

23 2nd Fl Front Rm, Firehouse (Bldg #30)

Flr Material 2nd Layer Not Analyzed

Detected Chrysotile 5 black Non-Fibrous 95

1630744

24 2nd Fl Front Rm, Firehouse (Bldg #30)

Mastic 3rd Layer

1630745

25 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Carpet Glue 1st Layer Not Analyzed

1630746

26 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Fl Material 2nd Layer Not Analyzed

1630747

27 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Mastic 3rd Layer Not Analyzed tan Non-Fibrous 100

1630748

28 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Formica Glue None Detected tan Cellulose 20 Non-Fibrous 80

1630749

29 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Sink Under Coating None Detected brown Non-Fibrous 100

1630750

30 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Cove Base None Detected tan Non-Fibrous 100

1630751

31 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Glue None Detected tan Non-Fibrous 100

1630752

32 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

1'x1' Fl Tiles None Detected

Sampled: Received: October 31, 2025October 29, 2025 Analyzed:October 27, 2025

Analyzed by: 144513Batch:

11 Old Farm Road Woodbridge, CT 06525

Project Information

30-32 North Main St., Kent, CT

Method: BULK PLM ANALYSIS, EPA/600/R-93/116

Asbestos %Material Color Non-Asbestos %LocationFieldID

LabID tan Non-Fibrous 100

1630753

33 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

1'x1' Fl Tiles None Detected black Non-Fibrous 100

1630754

34 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Mastic None Detected black Non-Fibrous 100

1630755

35 2nd Fl Room by Kitchen, Firehouse (Bldg #30)

Mastic None Detected brown Non-Fibrous 100

1630756

36 1st Fl Bathroom, Firehouse (Bldg #30)

Cove Base None Detected tan Non-Fibrous 100

1630757

37 1st Fl Bathroom, Firehouse (Bldg #30)

Glue None Detected tan Non-Fibrous 100

1630758

38 1st Fl Bathroom, Firehouse (Bldg #30)

1'x1' Fl Tiles None Detected tan Non-Fibrous 100

1630759

39 1st Fl Bathroom, Firehouse (Bldg #30)

1'x1' Fl Tiles None Detected tan Non-Fibrous 100

1630760

40 1st Fl Bathroom, Firehouse (Bldg #30)

Glue None Detected tan Non-Fibrous 100

1630761

41 1st Fl Bathroom, Firehouse (Bldg #30)

Glue None Detected gray Non-Fibrous 100

1630762

42 1st Fl Rear Room, Firehouse (Bldg #30)

Brick Mortar None Detected gray Non-Fibrous 100

1630763

43 1st Fl Rear Room, Firehouse (Bldg #30)

Breeching Grout None Detected

Detected Chrysotile 2 gray Non-Fibrous 98

1630764

44 Exterior (Bldg #30)Window Glazing

1630765

45 Exterior (Bldg #30)Window Glazing Not Analyzed

Sampled: Received: October 31, 2025October 29, 2025 Analyzed:October 27, 2025

Analyzed by: 144513Batch:

Reliance #25-LIBRARY-01 7 30-32 North Main Street, Kent, CT

IV. STATE OF CT ASBESTOS INSPECTOR LICENSE

1000435 SP 0664 -C01-P00437-I

VIDYA N. TRIVEDI

RELIANCE ENVIRONMNET AL LLC

11 OLD FARM RD

WOODBRIDGE CT 06525-2400

Dear VIDYA N. TRIVEDI , Attached you will find your validated certificate for the coming year. Should you have any questions about your certificate renewal, please do not hesitate to write or call:

Department of Public Health P .0. Box 340308

M.S.#12MQA

(860) 509-7603 oplc.dph@ct.gov www.ct.gov/dph/license Hartford, CT 06134-0308

MANISHA JUTHANI, MD, COMMISSIONER

DEPARTMENT OF PUBLIC HEALTH

STATE OF CONNECTICUT

DEPARTMENT OF PUBLIC HEALTH

PURSUANT TO THE PROVISIONS OF THE GENERAL STATUTES OF CONNECTICUT

THE INDIVIDUAL NAMED BELOW IS CERTIFIED

BY TIIIS DEPARTMENT AS A

ASBESTOS CONSULT ANT-PROJECT DESIGNER

CERTIFICATE NO.

VIDYA N. TRIVEDI

000017

CURRENT 11-IROUGH

03/31/26

VALIDATION NO.

03-172601

EMPLOYER'S COPY

ST ATE OF CONNECTICUT

DEPARTMENT OF PUBLIC HEALTH

NAME

VIDYA N. TRIVEDI

VALIDATION NO. CERTIFICATE NO. CURRENT THROUGH

03-172601 000017 03/31/26

PROFESSION

ASBESTOS CONSULTANT-PROJECT DESIGNER

~±¥ N• r/iw M~HA ,CO~SIONER

:I• -- - _______ ..._ __ ..__..___..........._.. _..__ __ ..._ __ ...._..__ ____ ..__. __ ..._..,_..,_r_.._. _____________ _

INSTRUCTIONS:

I . Deta ch and ll i).! n eac h or th e ca rds on 1his form

2. Di~play the large ca rd in u promincnl place in ~our Mfin • or ll lun· of ht1 !1 ill r!lll.

3. The \\ Ull ct ca n.I is for ~o u to rn rry on yo ur perso n. If you do not n ill h 10 c 111-r~ 1hc \\ a lk1 c:trcl. place it in a sec ure pl :tce.

-4 . The emp loye r 's copy is fo r perso ns "ho must demonstrat e cunent liccnsure/n;rtifi ca ti on in ordc,· to r eta in employ·ment o r prhileges. The employer ·s ciu-d i,; to bl' prcscnll'd lo lhl' emp loyer and kepi by them as a part or your perso nnel fil e. O nly one copy of th is ca rd ca 11 he 'i llJlplicd to ~OIi.

WALL.Hf CARD

STATE OF CONNECTICUT

DEPARTMENT OF PUBLIC HEALTH

NAME

VIDYA N. TRIVEDI

VALIDATION NO. CERTIFICATE NO. CURRENT THROUGH

03-172601 000017 03/31/26

PROFESSION

ASBESTOS CONSUL TANT-PROJECT DESIGNER

l6& ~1

• 1~~HA .co=oNER

I. PROJECT NARRATIVE
Overview
Summary of Results
II. SAMPLE LOG AND RESULTS TABLE
BULK SAMPLES COLLECTED ON 10-27-25
III. CHAIN OF CUSTODY & LAB ANALYSIS SHEETS FOR ASBESTOS
IV. STATE OF CT ASBESTOS INSPECTOR LICENSE

Other files

File Type Posted
KML Addendum 1 - 2025-11-07.pdf PDF
33247_Jan_27_26_solicitation_doc.pdf PDF
3-11-19-25-LIBRARY-01 LEAD-XRF - 30-32 NORTH MAIN STREET KENT CT.pdf PDF
000100 Definitions and Standards.pdf PDF
000200 General Information.pdf PDF
2025-11-20 Addendum 3 drawings.pdf PDF
109990 - Tower Clock.pdf PDF
Addendum 2 - 2025-11-12.pdf PDF
KML Civil Bid Set Drwgs 10-20-25.pdf PDF
Addendum 4 - 2025-11-24.pdf PDF
003126 - EXISTING HAZARDOUS MATERIAL INFORMATION_rev1.pdf PDF
Addendum 5 - 2025-12-02.pdf PDF
Addendum 3 - 2025-11-20.pdf.crdownload CRDOWNLOAD file
088000 - GLAZING_rev1.pdf PDF
1-11-4-25-MAIN LIBRARY-01 INSP - 30-32 NORTH MAIN STREET KENT CT.pdf PDF
10-20-25-abbreviated bid ad -1.docx DOCX document
014523 - TESTING FOR INDOOR AIR QUALITY_rev1.pdf PDF
IQT-WA-32 North Main Street-Firehouse-02-04-22.pdf PDF
2025-11-20 Addendum 3 drawings.pdf.crdownload CRDOWNLOAD file
2025-11-20 KML Lead Asbestos Letter.pdf PDF
KML Arch Bid Set 10-15-25.pdf.crdownload CRDOWNLOAD file
KML Drwgs for Printing 10-15-25.pdf.crdownload CRDOWNLOAD file
000400 - BID FORM_rev1.pdf PDF
10-28-25 Bid Ad.docx DOCX document
IQT-WA-32 North Main Street-Library-02-11-22.pdf PDF
2-11-4-25-LIBRARY-01 LEAD-XRF - FIREHOUSE-MAIN STREET KENT CT.pdf PDF
Addendum 3 - 2025-11-20.pdf PDF
3-11-19-25-LIBRARY-01 LEAD-XRF - 30-32 NORTH MAIN STREET KENT CT.pdf.crdownload CRDOWNLOAD file
IQT-WA-32 North Main Street-Firehouse-02-04-22.pdf.crdownload CRDOWNLOAD file
KML MEP Bid Set Drwgs 10-15-25.pdf PDF
102800 - Toilet Bath and Custodial Accessories.pdf PDF
KML Proj Manual- Bidding 10-15-25.pdf.crdownload CRDOWNLOAD file
KML Civil Bid Set Drwgs 10-20-25.pdf.crdownload CRDOWNLOAD file
KML Arch Bid Set 10-15-25.pdf PDF
Addendum 4 drawings - 2025-11-24.pdf PDF
KML Drwgs for Printing 10-15-25.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .