MS 026 Cove Base Submittal.pdf

PDF 939 KB Posted

Attached to
Repair Maintenance Shop BLDG 8040
Solicitation number
FA4661-21-R-0001
Issued by

View the file

Other files

File Type Posted
AF Form 3065 Dyess Progress Report 42 Gov.pdf PDF
12-0053 Addendum Four - New Contractor (11-19-20) v2.doc DOC document
12-0053 Addendum Three - New Contractor (11-9-20).pdf PDF
Solicitation Amendment FA466121R00010001 SF 30.pdf PDF
12-0053 Attachment C - Contractor Pricing Breakdown 11.29.16.xlsx XLSX spreadsheet
MS 004 Staging Plan.pdf PDF
MS 039 HM Doors Frames and Hardware.pdf PDF
MS 032 Concrete Vapor Barrier.pdf PDF
MS 042A Overhead Coiling Doors.pdf PDF
MS 030 Steel Shop Drawings.pdf PDF
MS 024 MBCI Panel Roof and Color Chart.pdf PDF
MS 037 MBCI and Welding Certifications.pdf PDF
AF Form 3065 Dyess Progress Report 42 Gov.pdf PDF
MS 044 Casework.pdf PDF
MS 079 Radius Bullnose for Doorways.pdf PDF
MS 007 Mech and Plumb Consumables.pdf PDF
MS 027-028 Metal Slat Fencing - Color.pdf PDF
MS 011 Fire Alarm and Mass Notification MS 005a.pdf PDF
MS 025 VCT.pdf PDF
MS 070 Water Meter Specifications.pdf PDF
MS 073 Breakroom Sink Type and Color.pdf PDF
MS 031A Toilet Partions and Accessories.pdf PDF
MS 016 HVAC Controls.pdf PDF
MS 055 South Structural Steel.pdf PDF
MS 006 Mech and Plumb.pdf PDF
MS 008 Abatement Plan.pdf PDF
MS 069 Sidewall Sprinkler Head.pdf PDF
MS 076 Backflow Preventer.pdf PDF
MS 064 Dryvit Backstop Air Barrier.pdf PDF
MS 021 HVAC.pdf PDF
MS 050 Welder Certification.pdf PDF
MS 083 Aerospace Air Shower Substitution.pdf PDF
MS 030 Steel Shop Drawings Page 2.pdf PDF
MS 029 Anchor Rod Shop Drawings and Details.pdf PDF
MS 001 QC Plan.pdf PDF
MS 065 Concrete Test Reports.pdf PDF
MS 020A Electrical Transformer.pdf PDF
MS 041 Toilet Accessories and Fire Ext.pdf PDF
MS 022 Louvers and Color Chart.pdf PDF
MS 035 Geotech Compaction Testing.pdf PDF
MS 078 078A Overhead Doors Warranty.pdf PDF
MS 023 Metal Panels.pdf PDF
MS 047 28 Day Concrete Test Results.pdf PDF
MS 061 Masonry Sealant Substitution.pdf PDF
MS 066 Roof Flashing.pdf PDF
REF 12 0053 PR 42 Thru 09 30 2019.xlsx XLSX spreadsheet
MS 010 Insulation.pdf PDF
MS 067 Steel Building Certifications.pdf PDF
MS 052 CMU Specs and Certs.pdf PDF
MS 036 MBCI Panels.pdf PDF
Show 40 more

Latest 50 of 163 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

MATERIAL APPROVAL SUBMITTAL

(See Instructions on Reverse)

Form Approved OMB No 9000-0062

Expires May 31, 2005

Public reporting burden for this collection of information is estimated to average 20 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to the Department of Defense, Washington Headquarters Services, Directorate for Information Operations and

Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project OMB No 9000-0062, Washington DC 20503. Please DO NOT RETURN your form to either of these addresses. Send your completed form to: SAF/AQCP, 1060 Air Force Pentagon, Washington DC

TO: (Contracting Officer) FROM: (Contractor) DATE

CONTRACT NUMBER SUBMISSION NUMBER SUBMITTAL

PREVIOUS SUBMISSION NUMBER PROJECT NUMBER

TO BE COMPLETED BY CONTRACTOR FOR GOVERNMENT USE ONLY

ITEM

NO.

SPECIFICATION SECTION/

PARA NO./DRAWING NO.

DESCRIPTION OF MATERIAL

(Include Type, Model Number, Catalog Number, Mfg., etc.)

AP-

PROVED

DISAP-

PROVED

SEE

REVERSE

INITIAL

BY COMPLETING THIS FORM, THE UNDERSIGNED CONTRACTOR CERTIFIES THAT

THE MATERIAL COMPLIES WITH ALL SPECIFICATIONS OF SUBJECT CONTRACT.

DATE (YYYYMMDD) TYPE OR PRINT NAME AND GRADE SIGNATURE

FOR GOVERNMENT USE ONLY

TO: (Base Civil Engineering Officer)

For Evaluation and Action RNLT ________________ OR SOONER

TO: (AF Contracting Office)

RECOMMEND APPROVAL DISAPPROVAL AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE

TO: (Contractor)

APPROVED

DISAPROVED AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE SIDE. REQUEST

RESUBMITTAL ON DISAPPROVED ITEMS WITHIN ____ DAYS OF DATE SHOWN BELOW.

AF IMT 3000, 20030901, V1 PREVIOUS EDITION IS OBSOLETE.

New Resubmittal

COMMENTS

(Number to correspond with applicable Item Number on reverse)

INSTRUCTIONS TO CONTRACTORS

1. The term "material" is defined as articles, supplies, raw materials, equipment, parts, components, and end items that are to be incorporated into the work required by the contract.

2. This form is to be used by contractors for submitting Shop Drawings, Equipment Data, Manufacturer's Literature and Certificates and samples of Materials to the Government for approval in accordance with the provisions of this contract. Unless otherwise specified, it is to be prepared in 4 copies, signed, and provided to the contracting officer with appropriate attachments.

3. Item(s) to be approved will be clearly tabbed or identified. Data pertaining to item(s) to be approved will be clearly identified or tabbed, particularly where documents are voluminous, in order to properly evaluate the materials or articles to be incorporated in the work. Each attachment will be numbered to correspond with the item number shown on the face of this form.

4. Requests submitted shall be numbered consecutively, by contract, in the space entitled "Submission No.". This number, in addition to the Contract No., will be used to identify each Material Approval Submittal. Resubmissions will be indicated in the appropriate block and the insertion of previous submission number and data in addition to a new submission number. A single submission should be used for all work of a section of the specifications, but in NO instance should the submission include work for more than one (1) contract. Submittals requiring priority handling will be submitted by separate submittal using the form and so marked across the face of the form.

5. This Material Approval Submittal is not valid unless it is signed by the contracting officer. This approval is required as called for by the contracting officer under the terms of this contract.

AF IMT 3000, 20030901, V1 (REVERSE)

TO Contracting Officer: SrA Vitaliy Poprozhuk

FROM Contractor: FARR Builders LLC S. Gevers, San Antonio, TX 78210

DATE: 26 January 2018

CONTRACT NUMBER: FA4661-15-D-0001

SUBMISSION NUMBER: 26

PREVIOUS SUBMISSION NUMBER: 25

PROJECT NUMBER: FNWZ 12-0053

ITEM NORow1: 1

SPECIFICATION SECTION PARA NODRAWING NORow1: Per SOW

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow1: Roppe 700 Series Cove Base Color Chart

INITIALRow1: PR

ITEM NORow2: 2

SPECIFICATION SECTION PARA NODRAWING NORow2: Per SOW

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow2: Roppe 700 Series Product Speciifications

INITIALRow2: PR

ITEM NORow3: 3

SPECIFICATION SECTION PARA NODRAWING NORow3: Per SOW

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow3: Roppe 700 Series Warranty

INITIALRow3: PR

ITEM NORow4: 4

SPECIFICATION SECTION PARA NODRAWING NORow4: Per SOW

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow4: Roppe 700 Series Maitenance

INITIALRow4: PR

ITEM NORow5: 5

SPECIFICATION SECTION PARA NODRAWING NORow5: Per SOW

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow5: Roppe 700 Series Product Specs

INITIALRow5: PR

ITEM NORow6:

SPECIFICATION SECTION PARA NODRAWING NORow6:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow6:

INITIALRow6:

ITEM NORow7:

SPECIFICATION SECTION PARA NODRAWING NORow7:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow7:

INITIALRow7:

ITEM NORow8:

SPECIFICATION SECTION PARA NODRAWING NORow8:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow8:

INITIALRow8:

ITEM NORow9:

SPECIFICATION SECTION PARA NODRAWING NORow9:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow9:

INITIALRow9:

ITEM NORow10:

SPECIFICATION SECTION PARA NODRAWING NORow10:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow10:

INITIALRow10:

ITEM NORow11:

SPECIFICATION SECTION PARA NODRAWING NORow11:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow11:

INITIALRow11:

DATE YYYYMMDD: 2018/01//26

TYPE OR PRINT NAME AND GRADE: Wayne Owens, Project Supt.

TO Base Civil Engineering Officer: 502 CE

RNLT:

DATE YYYYMMDD_2: 20180131

TYPE OR PRINT NAME AND GRADE_2: A1C Yeongsoo Jeon

TO AF Contracting Office: 7 CONS

DATE YYYYMMDD_3: 20180131

TYPE OR PRINT NAME AND GRADE_3: Patrick Rolan, GS-12

TO Contractor: FARR Builders LLC

DATE YYYYMMDD_4: 20180131

TYPE OR PRINT NAME AND GRADE_4: Capt Hilary Ince

2018-01-31T16:21:08-0600

JEON.YEONGSOO.1538040130

2018-01-31T16:06:27-0600

ROLAN.PATRICK.M.1515150249

2018-01-31T16:26:06-0600

INCE.HILARY.RAE.1368173785

Text5:

Check Box6: Yes

Check Box7: Off

Check Box8: Yes

Check Box9: Yes

Check Box10: Off

Check Box11: Off

Check Box12: Yes

Check Box13: Off

Check Box14: Off

Check Box15: Yes

Check Box16: Off

Check Box17: Off

Check Box18: Yes

Check Box19: Off

Check Box20: Off

Check Box21: Off

Check Box22: Off

Check Box23: Off

Check Box24: Off

Check Box25: Off

Check Box26: Off

Check Box27: Off

Check Box28: Off

Check Box29: Off

Check Box30: Off

Check Box31: Off

Check Box32: Off

Check Box33: Off

Check Box34: Off

Check Box35: Off

Check Box36: Off

Check Box37: Off

Check Box38: Off

Check Box3: Yes

Check Box4: Yes

Check Box5: Off

Check Box40: Off

COMMENTS Number to correspond with applicable Item Number on reverseRow1: 1. color selection: 193 Black Brown

Check Box39: Yes

Check Box50: Off

07.06.2017 | Page 1

P R O D U C T S U B M I T T A L T P R W A L L B A S E

700 series

Roppe Corporation | 1602 N. Union St. - Fostoria, OH 44830 | (800) 537 - 9527

700 Series Wall Base, 6" Cove Manufacturer Roppe Corporation 1602 N. Union Street P.O. Box 1158 Fostoria, Ohio USA 44830-1158 Website - www.roppe.com t: (419) 435.8546 tf: (800) 537.9527 f: (419) 435.1056 e-mail: sales@roppe.com

Product Description Our 700 Series wall base is an outstanding selection for any installation. Easier to work with and providing more flexibility than vinyl base products, Roppe's unique blend of thermoplastic rubber and vinyl makes the 700 Series an attractive and economical choice for a variety of applications.

Features Extremely Durbale and Flexible Will not Shrink, Gap or Cup Recycleable (IMPACT Recycling Program) Qualifies for LEED® Credits FloorScore® Certified

700 Series, 6"

Technical Data LEED v2009 IEQ Credit 4.1: Qualifies ASTM F1861 - Resilient Wall Base: Type TP, Group 2, Style B ASTM E648 (NFPA 253) - Critical Radiant Flux: Class I, > 0.45 W/cm2 ASTM E662 (NFPA 258) - Smoke Density: Passes, <450 ASTM E84 - Flammability: Class A attach color submittal sample here

*For complete adhesive, installation & maintenance instructions, visit www.roppe.com

Warranty Roppe Provides a 2 year Limited Warranty on all 700 Series Wall Base. For additional information, see associated Warranty documents.

Technical Document Support Additional product resources and technical documents are available online at www.roppe.com. For additional technical support, send an e-mail to solutions@roppe.com

Availability, Cost & Samples Roppe Flooring products are sold through distribution.

To locate the nearest distributor, visit www.roppe.com. or send an email to solutions@roppe.com

Installation* (Visit our website for complete Installation instructions)

All material is to be delivered to the installation location in its original packaging with labels intact. The installation area, unboxed wall base and adhesive are to be maintained between 65° (19°C) and 85° (30°C) for at least 48 hours before installation, during installation and thereafter. Proceed with the installation only when the conditions are proper and correct. Inspect all material for proper type and color. A bond test should be performed at least 72 hours prior to the scheduled installation to ensure the surface is suitable and there should be extreme difficulty in removing the wall base from the surface.

Adhesives* (Visit our website for complete Adhesive instructions)

AW-510 Acrylic Wet-Set Adhesive Unit Size: 1 or 4 Gallon Units VOC: < 0.1 g/l Coverage Rate: 160 sq. ft. per gallon Substrate: Porous WB-600 Acrylic Wall Base Adhesive Unit Size: 30 oz. Cartridge, 1 Gallon and 4 Gallon Units VOC: < 12 g/l Trowel Coverage Rate: 180-340 lin. ft. per gallon Cartridge Coverage Rate: 30-70 lin. ft. per cartridge Substrate: Porous C-630 Contact Adhesive Unit Size: 1 Quart VOC: 0.0 g/l Coverage Rate: 20-40 sq. ft. per unit or 120-140 lin. ft.

per unit.

Substrate: Non-Porous

Maintenance* (Visit our website for complete Maintenance instructions)

700 Series wall base can be cleaned with a neutral pH cleaner and a soft wet cloth.

CAN/ULC-S102.2 - Surface Burning: FSR 10, SDS 60 Acclimation Time: 48 Hours Storage & Acclimation Temperature: 65 ° - 85 ° F

Toe Type:

Base Height:

Base Thickness:

Base Length:

Carton Quantity:

Carton Weight:

Cove 6" (152.1 mm) 1/8" (3.2 mm) 48" Sections or 120' ft. Coils 30 pieces or 1 coil 62 lbs.

Additional Accessories: Inside and outside factory corners are available to match wall base installations.

12.29.2017 | Page 1

T E C H N I C A L D A T A S H E E T T P R W A L L B A S E

• Extremely Durable

• Extremely Flexible

• Will Not Shrink, Gap or Cup

• Recycleable (IMPACT Recycling Program)

• Qualifies for LEED® Credits

• FloorScore® Certified

Product Description

Technical Data

Roppe 700 Series Wall Base is a unique thermoplastic rubber (TPR) wall base product that is as attractive as it is affordable. 700 Series wall base is incredibly durable, allowing it to stand up to a wide range of use when compared to vinyl wall base.

700 Series wall base is designed for use in both commercial and residential wall base applications.

700 Series wall base is available in various heights, from 2 1/2" to 6", and in cove or no toe to match a variety of flooring installations and application requirements.

700 Series wall base is FloorScore certified, contributes to LEED credits and meets a variety of VOC requirements. 700 Series wall base is manufactured in the USA.

Toe Styles:

Nominal Base Height:

Nominal Base Length:

Nominal Base Thickness:

LEED v2009 IEQ Credit 4.1:

ASTM F1861 – Resilient Wall Base:

ASTM E648 (NFPA 253) - Critical Radiant Flux:

ASTM E662 (NFPA 258) - Smoke Density:

ASTM E84 - Flammability:

CAN/ULC-S102.2 - Surface Burning:

Acclimation Time:

Storage & Acclimation Temperature:

Cove, No Toe

2 1/2" (63.5 mm) 4" (101.6 mm) 4 1/2" (114.3 mm)

48" Sections (1.22 m) 120' Rolls (36.58 m)

1/8" (3.2 mm)

Qualifies

Type TP, Group 2, Style A & B

Class I, > 0.45 W/cm2

Passes, <450

Class A

FSR 10, SDS 60

48 Hours

65° - 85° F

Features

Approved Adhesives AW-510 Acrylic Wet-Set Adhesive WB-600 Acrylic Wall Base Adhesive C-630 Contact Adhesive

Additional Accessories Inside and outside factory corners, are available to match wall base installations.

Custom Offerings Product color may be altered to match other colors in 12 carton increments with a minimum of 48 cartons.

Availability, Cost & Samples Roppe Flooring products are sold through distribution. To locate the nearest distributor, visit roppe.com or send an e-mail to support@roppe.

com.

Technical Documents & Support Additional product resources and technical documents are available online at roppe.com. For additional technical support, send an e-mail to solutions@rhctechnical.com.

Additional Information

T E C H N I C A L D A T A S H E E T

12.29.2017 | Page 2Roppe Corporation | 1602 N. Union St. - Fostoria, OH 44830 | (800) 537 - 9527

T P R W A L L B A S E

Base Thickness:

Base Length:

Carton Weight - 2 1/2":

Carton Weight - 4":

Carton Weight - 4 1/2":

Carton Weight - 6":

2 1/2" (63.5 mm), 4" (101.6 mm), 4 1/2" (114.3 mm), 6" (152.1 mm) 1/8" (3.2 mm) 48" (1.22 m) Sections 120' (36.58 m) Coils 30 Pieces / 1 Coil 27 lbs.

42 lbs.

45 lbs.

62 lbs.

Cove Base No Toe Base

Wall Base & Corners

Base Thickness:

Base Length:

1/8" (3.2 mm) 48" (1.22 m) Sections 120' (36.58 m) Coils 30 Pieces / 1 Coil 25 lbs.

41 lbs.

60 lbs.

Corner Type:

Corner Height:

Corner Thickness:

Corner Return Length:

Corner Carton Quantity:

Inside & Outside

6" (152.1 mm) 1/8" (3.2 mm) 3" 25 Pieces 2 lbs.

3.8 lbs.

5 lbs.

Cove Base Factory Corners

1. PRE-INSTALLATION CHECKLIST

• Consult all associated product literature concerning installation and warranty prior to installation.

• Allow all trades to complete work prior to installation.

• Deliver all materials to the installation location in its original packaging with labels intact.

• Inspect all materials to ensure there is no damage.

• Do not stack pallets to avoid damage.

• Ensure installation area and material storage temperatures are between 65º F (19º C) and 85º F (30º C) and 40% - 65% RH for at least 48 hours before, during and after installation.

• Ensure HVAC system is operational and fully functioning at normal operating conditions 48 hours prior to, during and 48 hours after installation.

• Protect installation area from extreme temperature changes, such as heat and freezing, as well as direct sunlight for at least 48 hours before, during and after installation.

• Do not proceed with installation until all conditions have been met.

2. PRODUCT LIMITATIONS

Do not install materials over existing wall base, flash-coved rubber, vinyl or linoleum flooring, cork, or asphaltic materials. Do not install wall base materials in outdoor areas and in or around commercial kitchens. Do not install in areas that may be subjected to sharp, pointed objects. Do not allow product to be directly exposed to extreme heat sources, such as radiators, ovens or other high-heat equipment.

May be susceptible to staining from harsh disinfectants, cleaning agents, dyes or other harsh chemicals – ensure all chemicals and materials that may come in contact with wall base will not stain, mar or otherwise damage the material prior to use.

3. SUBSTRATE PREPARATION

All substrates must be clean, smooth, permanently dry, flat, and structurally sound. Substrates must be free of visible water or condensation, dust, sealers, water-based / acrylic paint, residual adhesives and adhesive removers, solvents, wax, oil, grease, asphalt, gypsum compounds, visible alkaline salts or excessive efflorescence, mold, mildew and any other extraneous coating, film, material or foreign matter.

Substrate must be a structurally sound interior wall surface, such as dry plaster, cured drywall, fiber-reinforced plastic (FRP) panels, fiberglass, exterior grade plywood (Group 1, CC type), concrete, metal and masonry. Any cracks, voids, Corner Type:

Corner Height:

Corner Thickness:

Corner Return Length:

Corner Carton Quantity:

Outside Only 2 1/2" (63.5 mm), 4" (101.6 mm) 1/8" (3.2 mm) 3" 25 Pieces 2 lbs.

3.8 lbs.

No Toe Base Factory Corners

12.29.2017 | Page 3Roppe Corporation | 1602 N. Union St. - Fostoria, OH 44830 | (800) 537 - 9527 as they may telegraph through wall base material.

5. WALL BASE INSTALLATION

Prior to installation, ensure wall base material has been properly acclimated and that ambient conditions are within normal operational ranges. Ensure substrate is suitably prepared prior to installation, as manufacturer is not responsible for substrates that have not been properly prepared. Ensure adhesive is approved for use with wall base material and that proper trowel or applicator type and size is used, as manufacturer is not responsible for any and all adhesion issues related to improper adhesive selection or usage.

Cut wall base to desired length and fit tightly against corner blocks or allow for job-site formed corners detailed in section 6.

Apply adhesive to the back of the wall base per adhesive instructions, ensuring that wet-set adhesives do not come within 1/4" of the top of the wall base.

Install wall base to substrate, ensuring that wall base material is not stretched or over-compressed during installation.

Stretching material or over-compressing seams and corners may cause wall base to shrink and/or curl/delaminate, respectively.

Periodically lift material to ensure proper adhesive transfer - adhesive should cover 90% of material. Using a suitable hand roller, carefully roll material in the direction of the last piece installed with a hand roller within 30 minutes of installation.

700 Series wall base and corner blocks installations can be enhanced by using Roppe’s matching Colored Caulk to fill any voids or imperfections. Allow wall base to cure for the required period of time - do not disturb wall base installation until curing time is complete.

6. JOB-SITE FORMED CORNERS

Ensure substrate is suitably prepared prior to installation, as manufacturer is not responsible for substrates that have not been properly prepared. Ensure adhesive is approved for use with wall base material and that proper trowel or applicator type and size is used, as manufacturer is not responsible for any and all adhesion issues related to improper adhesive selection or usage.

OUTSIDE CORNERS

To create an outside corner on-site using wall base material, position wall base material firmly against the wall, allowing wall base to overhang corner in the direction that it will be installed. Use a pencil to mark the center of the corner on the back of the wall base, ensuring pencil line is straight and runs from the top of the wall base to the base of the toe.

Reposition wall base material on a flat, stable surface, backside facing up.

Use a top-set gouge to create a center groove on the long side of the pencil line, removing ~30% of the wall base material. Ensure center groove is on the side of the line that is in the direction the wall base will be installed. Remove excess material from each side of the corner groove.

Use a pencil to mark 1" from the base of the toe on the center line. From the 1" mark, mark a straight line on a 45° angle to the base of the toe on either side of the center groove. Use the top-set gouge to cut two stress relief grooves along the pencil line. Use a knife to remove all excess material between the stress relief groove and the center groove.

While rolling to toe of the wall base up, fold wall base along center groove to form the corner. The top edge of the wall base should fit tight and flush to the wall's surface, while the toe should be rounded and sit flat on the surface of the divots, grout lines and imperfections must be filled with a patch or filler suitable for the substrate.

When installing directly over a resinous products, such as an epoxy paint, ensure that coating is dry to the touch and has cured for the prescribed length of time.

Substrate must be clean, dry, sound and free of contaminates. Material to be installed over non-porous substrates, such as epoxy paint, FRP panels or fiberglass, must be installed with the Excelsior C-630 Contact Adhesive.

Metal substrates must be thoroughly sanded/ground and cleaned of any residue, oil, rust and/or oxidation.

Substrate must be smooth, flat and sound prior to installation. When installing in areas that may be subject to topical water or moisture and/or high humidity, an anti-corrosive coating must be applied to protect metal substrate.

Contact a local paint or coating supplier for coating recommendations. Install wall base within 12 hours after sanding/ grinding to prevent re-oxidation. Metal substrates are non-porous – follow all installation instructions, trowel sizes and flash times for non-porous substrates.

4. FACTORY CORNER INSTALLATION

Roppe 700 Series Factory Corners, Corner Blocks and Micro Corner Blocks must be installed prior to 700 Series Wall Base materials. Ensure substrate is suitably prepared prior to installation, as manufacturer is not responsible for substrates that have not been properly prepared. Ensure adhesive is approved for use with wall base material and that proper trowel or applicator type and size is used, as manufacturer is not responsible for any and all adhesion issues related to improper adhesive selection or usage.

Corners and corner blocks must be installed on 90° corners - do not attempt to install corner blocks over other angles, including 135° angles. Install adhesive to the back of the corner or corner block and install onto corner. Mechanically fasten the returns / wings of corner blocks with staples or brad nails to increase stability.

When fastening, ensure that staples or nail heads do not protrude from return, Outside Corner Detail

12.29.2017 | Page 4Roppe Corporation | 1602 N. Union St. - Fostoria, OH 44830 | (800) 537 - 9527 floor.

Apply adhesive to the back of the wall base per adhesive instructions, ensuring that wet-set adhesives do not come within 1/4" of the top of the wall base, and install wall base to substrate.

INSIDE CORNERS - TOE

To create an inside corner using wall base material, position wall base material firmly against the wall and into the corner. Use a pencil to mark the center of the corner on the back of the wall base and make note of wall base installation direction (from left to right or right to left).

Reposition wall base material on a flat, stable surface, backside facing up. Prior to creating an inside corner, measure the distance from the end of the last piece of base installed to the inside corner. If the distance from the last piece of base installed and the corner is within 5', draw a center line 1/16" from initial center mark in the direction the wall base will be installed. If the distance is more than 5', draw a center line 1/8" from initial center mark in the direction the wall base will be installed. Ensure pencil line is straight and runs from the top of the wall base to the base of the toe.

Use a top-set gauge to create a center groove along the center line. Remove excess material from each side of the center groove. Fold wall base along center groove to form the inside corner.

Use a utility knife to cut a "V" into the toe from the base of the toe to the end of the toe. Ensure "V" is slightly less than 45° to avoid removing too much material.

Remove material to create a triangular void so that wall base can be installed into corner without the toe overlapping.

Make any final adjustments prior to installation.

Apply adhesive to the back of the wall base per adhesive instructions, ensuring that wet-set adhesives do not come within 1/4" of the top of the wall base, and install wall base to substrate. The top edge of the wall base should fit tight and flush to the wall's surface and previously installed wall base. Once properly positioned, apply firm pressure to the corner to adhere it to the wall. Roll wall base with a hand roller in the direction the material was installed.

INSIDE CORNERS - NO TOE

To create an inside corner on-site using wall base material, install one side of the inside corner as usual, ensuring that wall base is flush with adjoining wall.

Without applying adhesive, position the next section or coil of wall base on the adjoining wall with a ~1" gap from the installed material. Set a divider to the gap and move wall base material flush with the corner.

While applying firm pressure to the adjacent wall base corner with divider, mark the wall base with the divider to determine scribe line. Use a suitable knife to trim wall base along scribe mark.

Install wall base as usual, ensuring that wet set adhesives do not come within 1/4" of the top of the wall base and do not squeeze out of wall base corner.

7. INITIAL MAINTENANCE

Ensure that adhesive has cured for recommended period of time prior to conducting initial maintenance.

Remove any protective coverings prior to cleaning. Dust or wipe base to remove any dirt, dust or debris.

Mix 2-4 ounces of Excelsior All Purpose Cleaner per gallon of clean, potable water. Use a soft, clean cloth or towel to apply cleaning solution to clean wall base.

Do not use detergents or abrasive cleaners, as they will dull the finish and sheen of the material. Avoid contact with vacuums and cleaning machines, especially those that have a beater bar, or electric brooms, especially those with hard plastic bottoms or no padding, as this may cause discoloration, scratching and loss of sheen.

For further information regarding daily or routine maintenance, please consult the product care & maintenance document or the associated product technical data sheet.

8. PAINTING PROCEDURES

700 Series wall base may be painted, if desired. Once wall base has been cleaned and wall base is free of all residues which may interfere with bonding, the wall base must be primed prior to final painting. Be sure to select a high quality primer that is recommended and compatible with rubber and vinyl, such as a 100% acrylic or a 100% acrylic latex paint primer. Test compatibility on an un-installed piece of wall base to confirm adhesion, compatibility and performance.

Once the primer has properly dried, the wall base can be painted with a high quality acrylic latex paint. Follow all primer and paint manufacturer’s recommendations and guidelines.

Confirm proper maintenance procedures for paint prior to cleaning.

9. WARRANTY

Roppe provides a 2 year limited warranty for all 700 Series wall base. For additional information, see associated warranty documents.

FOR PROFESSIONAL USE ONLY. PLEASE CONSULT ALL ASSOCIATED TECHNICAL DATA SHEETS,

SAFETY DATA SHEETS, MAINTENANCE DOCUMENTS AND WARRANTY INFORMATION PRIOR TO

INSTALLATION.

01.30.2017 | Page 1

C A R E & M A I N T E N A N C E

Maintenance Overview TPR wall base does not typically require specialized maintenance within the parameters of a maintenance program. However, these products may require occasional cleaning, which is usually consistent with the adjoining floor covering. The frequency of daily and routine maintenance will depend upon the amount and type of traffic and wear in the area.

When installing 700 Series wall base in areas where desks, chairs and or furniture with castors will be used or in areas where auto-scrubbers and/or vacuums will be used, it is extremely important to protect the base from unnecessary damage due to moving furniture or equipment. Whenever possible, prevent damage and abuse to wall base.

Always use untreated, new or thoroughly cleaned cloth when conducting daily or routine maintenance. Do not use Kerosene, Gasoline, Naphtha and/or other solvents to clean wall base. As with any maintenance program, be sure to use proper PPE (Personal Protective Equipment) per the cleaning product SDS and ensure all maintenance procedures are conducted per the cleaning products instructions.

1. POST-INSTALLATION CHECKLIST

• When moving furniture or heavy equipment, protect wall base from scuffing and scratching that may not come out during the maintenance procedures.

• DO NOT use vacuums or electric brooms which have beater bars, hard plastic bottoms, a rubber bumper or are lacking proper padding or protection, as this may cause marking, discoloration, scratching and loss of sheen.

• DO NOT use detergents, abrasive, alkaline or acidic cleaners, cleaning agents which contain oil or solvents, as well as “mop and shine” type products, as they will dull the finish and sheen and potentially damage the wall base material.

• DO NOT clean area per the adhesives traffic limits (48-72 hours) to allow proper curing of the adhesive.

• DO NOT flood the area when cleaning.

• DO NOT allow the cleaning solution or topical moisture to work its way beneath the material, as this can result in an adhesive and/or installation failure.

2. INITIAL MAINTENANCE

Ensure that adhesive has cured for recommended period of time prior to conducting initial maintenance. Remove any protective coverings prior to cleaning. Sweep, dust or wipe material to remove any dirt, dust or debris. DO NOT use vacuums or electric brooms which have beater bars, hard plastic bottoms, a rubber bumper or are lacking proper padding or protection, as this may cause marking, discoloration, scratching and loss of sheen. Do not use detergents, abrasive cleaners or “mop and shine” type products, as they will dull the finish and sheen of the material.

Additional Information Approved Cleaners

• Excelsior NC-900 Neutral Cleaner

Approved Finish Removers

• Excelsior PR-930 Performance Remover

Technical Documents & Support Additional product resources and technical documents are available online at roppe.com. For additional technical support, send an e-mail to solutions@rhctechnical.com.

Mix 2-4 ounces of Excelsior NC-900 Neutral Cleaner per gallon of clean, potable water. Use a clean towel or cloth to apply cleaner to material. If heavily soiled, an additional cleaning may be required. Use clean towel or cloth to remove any and all excess cleaning solution. Rinse area with clean, cool water and allow material to dry entirely. Ensure material is clean and that all all cleaning residue has been removed (this may require additional rinsing).

3. DAILY MAINTENANCE

Ensure that initial maintenance has been conducted prior to conducting daily maintenance. Sweep, dust mop or wipe material to remove any dirt, dust or debris.

Mix 2-4 ounces of Excelsior NC-900 per gallon of clean, potable water. Use a clean mop or cloth to clean spills, dirt buildup and other debris. Allow material to dry before allowing foot traffic.

4. MATERIAL PROTECTION

Protect newly installed material with construction grade paper or protective boards, such as Masonite or Ram Board, to protect material from damage by other trades. Limit usage and foot traffic according to the adhesive's requirements.

When moving appliances or heavy furniture, protect wall base from scuffing and tearing using temporary floor protection.

For more information regarding cleaner application or finish removal, please consult the associated Excelsior product data sheet.

Revised on 5.24.2017 | Roppe Corporation | 1602 N. Union St. - Fostoria, OH 44830 | (800) 537 – 9527 | Page 1

Rubber & Vinyl Wall Base Limited Commercial Warranty

WARRANTY TERMS: Roppe (“Manufacturer”) warrants to its original purchaser that, at the time of delivery by the Manufacturer, the flooring products described in the Manufacturer’s Catalog as Rubber (TS) Wall Base, Thermoplastic Rubber (TP/TPR) Wall Base, and Vinyl (TV) Wall Base, (“Product” or “Products”) will conform to Manufacturer’s published technical documents.

Manufacturer’s Products include the following products:

700 Series AlphaBase Contours

Pinnacle Pinnacle Plus Vinyl Base

All warranties, whether expressed or implied, are contingent on the following requirements:

1. All Guidelines Must Be Reviewed. Installation and substrate preparation must be performed in accordance with all related ACI, ASTM, NWFA and RFCI guidelines (“Guidelines”).

2. All Technical Data Must Be Reviewed. Products must be installed in accordance with Manufacturer’s published architectural specifications, technical data sheets, care and maintenance documents and other relevant technical information provided by the manufacturer for the Products (“Technical Data”). This includes technical data sheets of all associated adhesive and maintenance products, as well as proper product and adhesive selection.

Manufacturer provides the following commercial warranties to its original purchaser:

1. Manufacturer’s Warranty. Products will conform to all written specifications and will be free of any and all manufacturing defects outside of normal tolerances. Warranty does not include any and all wear. Warranty will cover material and labor for a period of two (2) years from date of purchase, per the following pro-rated schedule:

a. Year 1: 100% Material costs, 100% of Labor costs

a. Year 2: 100% Material costs, 50% of Labor costs

These warranties are specific to the Products described in the Manufacturer’s Catalog and no other products.

The warranties are only provided original purchasing authority, company, person, entity, building and/or project and are non-transferable.

Products must be selected, installed, used, maintained and cared for in accordance with the Guidelines and Technical Data. Products must be installed by a professional, licensed and experienced installer only. Any installation by anyone other than a professional installer shall void any and all expressed or implied warranties. Guidelines may be obtained from the appropriate organization. Technical Data may be obtained at www.roppe.com and are available upon request (800) 537 - 9527.

WARRANTY EXCLUSIONS: The above warranties do not apply or cover any of the following:

1. Any expressed or implied promise made by any architect, designer, representative, sales agent, distributor or installer without expressed, written consent from Manufacturer’s technical staff.

2. Normal Product shade, color or dimensional variations that are within normal tolerances.

3. Products installed with visible and obvious manufacturing defects.

4. Products installed outside of product limitations found in Technical Data.

Revised on 5.24.2017 | Roppe Corporation | 1602 N. Union St. - Fostoria, OH 44830 | (800) 537 – 9527 | Page 2

5. Discoloration or damage caused by improper or incompatible cleaning products, floor finishes or finish removal products, as well as improper maintenance procedures, tools or machinery.

6. Discoloration or damage caused by subfloor or adhesive pH levels.

7. Discoloration or damage caused by direct and/or indirect UV light exposure.

8. Products that have not been installed in strict accordance with Guidelines and Technical Data.

9. Products that have not been installed with an explicitly compatible adhesive.

10. Products that have been damaged by excessive topical water, from such causes as improper or excessive maintenance, broken or leaking plumbing, sink overflow, flooding or weather conditions.

11. Products that have been damaged by hydrostatic pressure, osmosis, excessive subfloor moisture or moisture-related issues.

12. Products that have been damaged by negligence or accident, such as tears, burns or cuts.

13. Products that have been damaged by sharp, pointed objects, such as high heels, spikes or skates.

14. Products that have been damaged by incompatible materials, such as acids, alkalis and solvents.

15. Products that have been damaged by animal or vegetable fats, oils or grease and petroleum-based hydrocarbons.

16. Products that have been damaged by circumstances beyond the reasonable control of

Manufacturer, such as ambient or substrate conditions.

17. Products that have been damaged or deformed by substrate imperfections, damage or improper substrate selection (per the Technical Data) and installation.

18. Products that have been subjected to conditions of use or maintenance not in strict conformity with the Technical Data.

19. Any products that have been sold or resold as “seconds”, “mill-run”, “non-conforming”, “as is” or otherwise denoted as non-standard quality.

20. Unreasonable costs associated with product replacement, such as labor costs outside of pro-rated schedule, overtime and loss of use or business.

WARRANTY CLAIMS: If, within the applicable warranty period identified in the Warranty Terms, the original purchaser discovers any problems or defects in Products that may be covered by this Standard Limited Warranty, the original purchaser should notify the Manufacturer’s technical department in writing within fifteen (15) days of the appearance of defects or irregularities. If the Manufacturer determines that Products are covered by this Limited Warranty, then the Manufacturer shall, at its sole option and one time only, repair or replace the non-conforming Products or refund the purchase price paid for each defective Product and an amount up to the original cost of labor and material for the affected section of the floor, per the Warranty Terms. No warranty claims will be processed if received more than thirty (30) days after the applicable warranty period has ended.

All warranty claims must be directed to:

RHC Technical ATTN: Kim Jenkins 1602 N Union St.

Fostoria, OH 44830 P: (419) 436 - 4554 F: (844) 305 - 8358 E: kim@rhctechnical.com

Revised on 5.24.2017 | Roppe Corporation | 1602 N. Union St. - Fostoria, OH 44830 | (800) 537 – 9527 | Page 3

All claims should include a completed Claim Form, along with any associated photos and independent testing reports conducted prior to installation or independent inspection reports conducted after irregularities are observed or suspected.

Manufacturer, or its designated representative, shall have the right to examine the Products and the flooring (including testing of the flooring and substrate) at the installation site with respect to any warranty claim. Any removal of the installed Products prior to such examination will void this warranty.

Manufacturer may require additional testing or verification of any such test obtained by the original purchaser.

ADDITIONAL LIMITATIONS:

EXCEPT FOR THE EXPRESSED WARRANTIES ABOVE, MANUFACTURER MAKES NO REPRESENTATIONS

REGARDING THE PRODUCTS, THEIR USE OR PERFORMANCE AND DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, EXPRESSED AND IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE PRODUCTS, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-

INFRINGEMENT.

UNDER NO CIRCUMSTANCES WILL MANUFACTURER BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT, PUNITIVE OR SPECIAL DAMAGES, INCLUDING LOST PROFITS. IN NO EVENT SHALL MANUFACTURER LIABILITY EVER EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCTS AT ISSUE AND AN AMOUNT UP TO THE

ORIGINAL COST OF LABOR AND MATERIAL FOR THE AFFECTED INSTALLATION AREA.

THE PURCHASER ACKNOWLEDGES THAT THE REMEDIES PROVIDED IN THIS LIMITED WARRANTY ARE IT‘S SOLE

AND EXCLUSIVE REMEDIES, AND MANUFACTURER’S SOLE OBLIGATION, FOR ANY BREACH OF

REPRESENTATION OR WARRANTY, IS IN LIEU OF ALL OTHER REMEDIES.

PURCHASER MUST BRING ANY LEGAL ACTION FOR BREACH OF WARRANTY WITHIN

a. ONE YEAR AFTER THE CLAIM OR CAUSE OF ACTION HAS ACCRUED OR

b. PERIOD PRESCRIBED BY THE APPLICABLE STATUES OF LIMITATION OR REPOSE, WHICHEVER COMES

FIRST.

SOME STATES DO NOT ALLOW LIMITATIONS ON THE LENGTH OF IMPLIED WARRANTIES. THOUGH THIS WARRANTY GIVES THE PURCHASER SPECIFIC LEGAL RIGHTS, THE PURCHASER MAY ALSO HAVE ADDITIONAL LEGAL RIGHTS AFFORDED THEM BY THE APPROPRIATE STATE. EXCLUSIONS OR LIMITATIONS OF INCIDENTAL

OR CONSEQUENTIAL DAMAGES MAY VARY BY STATE. FOR FURTHER INFORMATION, CONSULT THE

APPROPRIATE STATE CONSUMER AFFAIRS OFFICE OR THE STATE ATTORNEY GENERAL’S OFFICE.

File details come from the government source that posted it. Updated .