MS 016 HVAC Controls.pdf

PDF 8 MB Posted

Attached to
Repair Maintenance Shop BLDG 8040
Solicitation number
FA4661-21-R-0001
Issued by

View the file

Other files

File Type Posted
AF Form 3065 Dyess Progress Report 42 Gov.pdf PDF
12-0053 Addendum Four - New Contractor (11-19-20) v2.doc DOC document
12-0053 Addendum Three - New Contractor (11-9-20).pdf PDF
Solicitation Amendment FA466121R00010001 SF 30.pdf PDF
12-0053 Attachment C - Contractor Pricing Breakdown 11.29.16.xlsx XLSX spreadsheet
MS 004 Staging Plan.pdf PDF
MS 039 HM Doors Frames and Hardware.pdf PDF
MS 026 Cove Base Submittal.pdf PDF
MS 032 Concrete Vapor Barrier.pdf PDF
MS 042A Overhead Coiling Doors.pdf PDF
MS 030 Steel Shop Drawings.pdf PDF
MS 024 MBCI Panel Roof and Color Chart.pdf PDF
MS 037 MBCI and Welding Certifications.pdf PDF
AF Form 3065 Dyess Progress Report 42 Gov.pdf PDF
MS 044 Casework.pdf PDF
MS 079 Radius Bullnose for Doorways.pdf PDF
MS 007 Mech and Plumb Consumables.pdf PDF
MS 027-028 Metal Slat Fencing - Color.pdf PDF
MS 011 Fire Alarm and Mass Notification MS 005a.pdf PDF
MS 025 VCT.pdf PDF
MS 070 Water Meter Specifications.pdf PDF
MS 073 Breakroom Sink Type and Color.pdf PDF
MS 031A Toilet Partions and Accessories.pdf PDF
MS 055 South Structural Steel.pdf PDF
MS 006 Mech and Plumb.pdf PDF
MS 008 Abatement Plan.pdf PDF
MS 069 Sidewall Sprinkler Head.pdf PDF
MS 076 Backflow Preventer.pdf PDF
MS 064 Dryvit Backstop Air Barrier.pdf PDF
MS 021 HVAC.pdf PDF
MS 050 Welder Certification.pdf PDF
MS 083 Aerospace Air Shower Substitution.pdf PDF
MS 030 Steel Shop Drawings Page 2.pdf PDF
MS 029 Anchor Rod Shop Drawings and Details.pdf PDF
MS 001 QC Plan.pdf PDF
MS 065 Concrete Test Reports.pdf PDF
MS 020A Electrical Transformer.pdf PDF
MS 041 Toilet Accessories and Fire Ext.pdf PDF
MS 022 Louvers and Color Chart.pdf PDF
MS 035 Geotech Compaction Testing.pdf PDF
MS 078 078A Overhead Doors Warranty.pdf PDF
MS 023 Metal Panels.pdf PDF
MS 047 28 Day Concrete Test Results.pdf PDF
MS 061 Masonry Sealant Substitution.pdf PDF
MS 066 Roof Flashing.pdf PDF
REF 12 0053 PR 42 Thru 09 30 2019.xlsx XLSX spreadsheet
MS 010 Insulation.pdf PDF
MS 067 Steel Building Certifications.pdf PDF
MS 052 CMU Specs and Certs.pdf PDF
MS 036 MBCI Panels.pdf PDF
Show 40 more

Latest 50 of 163 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

BUILDING AUTOMATION SYSTEMS

Fire - Security - CCTV - HVAC Control F:\CLIENT\ENER-TEL\DOCS\21-000\21-999FIRE

Dyess AFB Building 8040

1081 2nd St.

Repair Maintenance Shop

FNWZ 12-0053

BACnet Direct Digital Control System

Section 23 09 23.13 20

Submittal

Job# 4162

BUILDING AUTOMATION SYSTEMS

Fire - Security - CCTV - HVAC Control F:\CLIENT\ENER-TEL\DOCS\21-000\21-999FIRE

Datasheets (Sorted by Device ID# of Equipment Schedule on Sheet 1 of Shop Drawings)

© 2012 Kele, Inc. All rights reserved. The Kele name and logo are registered trademarks of Kele, Inc. kele.com 888-397-5353 USA 001-901-382-6084 International 931

RELAYS & CONTACTORS

RELAYS & CO

N

TACTO

RS

January 2012

RH SERIES

RR Series

RH SERIES (UL ratings)

RR SERIES (UL ratings)

RATED

VOLTAGE

RATED CURRENT (mA) ±15% @ 20°C 60 Hz 50 Hz

INRUSH CURRENT

(mA)

AC

DC

4PDT

3PDT

DPDT

SPDT

19.5 9.8

16.4 8.2

59.7 12.9 6.5

8.6 3.7

16.5 8.3

14.2 7.1

5.5

7.5 3.2

36.9

VOLTAGE

RESISTIVE (A) INDUCTIVE (A)

cos = 0.3 MOTOR LOAD (hp)

1/3 1/6

1/6

1/6

3PDTSPDT4PDT

240 AC

120 AC

30 DC

28 DC

Rated Voltage

Rated Current (mA) ±15% @ 20°C 60 Hz 50 Hz

INRUSH CURRENT

(mA)

20.5 10.5

12.1

RJ Series

* Note: 6.5A, 20A Total

VOLTAGE RESITIVE (A) INDUCTIVE (A)

cos = 0.3

MOTOR LOAD (hp)

1/4

240 AC

120 AC

30 DC

Maximum continuous applied voltage RH, RR 110% of rated voltage RJ 140% of rated voltage Pull-in voltage RH, RR, RJ/AC 80% of rated voltage RJ, RJ/DC 70% of rated voltage Drop-out voltage AC 30% or more of rated voltage DC 10% or more of rated voltage Contact material RH Silver cadmium oxide RR Silver RJ Silver nickel alloy Contact resistance RH 50 mΩ maximum RR 30 mΩ maximum RJ 50 mΩ maximum

Operate time RH, RR 25 ms maximum RJ 15 ms maximum Release time RH, RR 25 ms maximum RJ 10 ms maximum Min load RH 24 VDC/30 mA, 5 VDC/100 mA RR 24 VDC/10 mA, 5 VDC/20 mA RJ 5 VDC/100 mA Operating temp -22° to 158°F (-30° to 70°C) Agency approvals UL-recognized component, (RH, RR): File #E66043, (RJ): File #E55996 CSA certified, File #LR35144;

CE certified (not RR blade style) Warranty 1 year

COIL RATINGS CONTACT RATINGS

RJ1S RJ2S

12A @ 250 VAC/30 VDC

12A @ 250 VAC; 6A @ 30 VDC

7.5A @ 250 VAC; 6A @ 30 VDC

7.5A @ 250 VAC; 3A @ 30 VDC

N.O.

N.C.

N.O.

N.C.

Resistive Load (Maximum)

CONTACT

8A @ 250 VAC/30 VDC

8A @ 250 VAC; 4A @ 30 VDC

4A @ 250 VAC; 4A @ 30 VDC

4A @ 250 VAC; 2A @ 30 VDC

Inductive Load (Maximum)

Nominal Current Coil Resistance

25.7 mA

41.1 mA

8.1 mA

24V

24V 120V

DC Coil

Nominal Voltage

1080Ω 243Ω

5270Ω AC Coil (60 Hz)

Coil Sensitivity

IDEC GENERAL-PURPOSE RELAYS

RH, RJ, RR SERIES

DESCRIPTION

IDEC general-purpose relays are available in the RH Series blade-style relays and the RR Series pin-style relays and the RJ Series compact relays.

The RH Series features a 10A switching capacity. They are available in SPDT, DPDT, 3PDT, and 4PDT contact confi gurations, driven by AC or DC coils, and they have blade terminals for socket mounting.The RR Series has a 10A contact rating.

The RR Series relays are available in SPDT, DPDT, and 3PDT confi gurations driven by AC or DC coils, and they have pin or blade terminals for socket mounting.

The RJ Series is compact to reduce space requirements.

They are available in a 12A SPDT version and an 8A DPDT version. They are driven by AC or DC coils and have blade terminals for socket mounting.

FEATURES

• Blade style, pin style, and compact models

• Indicator light and/or check button available

• Surface or DIN rail mount

• UL recognized, CSA certifi ed

SPECIFICATIONS

RH, RJ, RR Series

001-901-382-6084 International 888-397-5353 USA kele.com © 2012 Kele, Inc. All rights reserved. The Kele name and logo are registered trademarks of Kele, Inc.

RE

LA

YS

C O

TA

CT

IDEC GENERAL-PURPOSE RELAYS

RH, RJ, RR SERIES

1.39 (3.56) or less in (cm)

2.19 (5.55)

0.55 (1.39) 0.82 (2.1)

1.

2.

1.22 (3.1)

1.14 (2.9) 1.42 (3.6) 1.87 (4.8) or less 1.42 (3.64)

0.2 (0.5)

1.42 (3.64)

(3

.6

(3

.6

RR2P RR1BA, RR2BA, RR3B

RR Series Power Relays (blade)

RH Series Relays (blade)

RR3PA

RH2B RH3BRH1B

1.60 (4.1)

RH4B

RR Series Relays (pin)

1 5

1.06 (2.7) 0.5 (1.27)

RJ Series Relays (blade)

4 5

1 8

RR2P

3 9

2 10

1 11

RR3PA

A B

RR1BA

BA

RR2BA

BA

RR3B

13 14

RH1B

13 (-) 14(+)

RH3B

13 (-) 14(+)

RH4B

13 14(-) (+)

RH2B

1 5 1 8

RJ1S RJ2S

WIRING

DIMENSIONS

ORDERING INFORMATION

RH1B U AC24V

Example: RR2PUAC24V DPDT relay 8 pin with 24VAC coil

U Standard relay UL Indicator light ULC Indicator light and check button

AC12V 12 VAC coil voltage AC24V 24 VAC coil voltage AC120V 120 VAC coil voltage AC240V 240 VAC coil voltage DC12V 12 VDC coil voltage DC24V 24 VDC coil voltage

MODEL DESCRIPTION

RH1B Relay, SPDT, blade (use SH1B-05 socket) RH2B Relay, DPDT, blade (use SH2B-05 socket) RH3B Relay, 3PDT, blade (use SH3B-05 socket) RH4B Relay, 4PDT, blade (use SH4B-05 socket)

RJ1S C A24

C No options CL LED indicator

A24 24 VAC coil voltage A120 120 VAC coil voltage D24 24 VDC coil voltage

RJ1S Relay, SPDT (use SJ1S-05B socket) RJ2S Relay, DPDT (use SJ2S-05B socket)

RR2P U AC24V

U Standard relay UL Indicator light ULC Indicator light and check button

AC12V 12 VAC coil voltage AC24V 24 VAC coil voltage AC120V 120 VAC coil voltage AC240V 240 VAC coil voltage DC12V 12 VDC coil voltage DC24V 24 VDC coil voltage

RR2P Relay, DPDT, 8 pin (use SR2P-05 or SR2P-06) RR3PA Relay, 3PDT, 11 pin (use SR3P-06 socket) RR1BA Relay, SPDT, 11 blade (use SR3B-05 socket) RR2BA Relay, DPDT, 11 blade (use SR3B-05 socket) RR3B Relay, 3PDT, 11 blade (use SR3B-05 socket)

Legend

NC

NO

Bottom View

RELATED PRODUCTS PAGE

DINRSTL, DINRALU DIN rail 229 brian.miller

Highlight

© 2012 Kele, Inc. All rights reserved. The Kele name and logo are registered trademarks of Kele, Inc. kele.com 888-397-5353 USA 001-901-382-6084 International 933

TACTO

Model Socket Type Rated

Rated Current

Hold Down Clip or SpringWire Size Wire Size Weight Approvals

SJ1S-05B Blade, DIN rail or surface mount 250V 12A Lever: SJ9Z-C1 (provided) Two 14 AWG 0.06 lb (0.03 kg) UL recognized File #E62437, CSA certifi ed File #LR84913, CE

SJ2S-05B Blade, DIN rail or surface mount 250V 8A Lever: SJ9Z-C1 (provided) Two 14 AWG 0.07 lb (0.034 kg) UL recognized File #E62437, CSA certifi ed File #LR84913, CE

SH1B-05 Blade, DIN rail or surface mount 250V 10A Spring: SYS-02F1;

Clip: SFA-101, SFA-202 Two 12 AWG 0.06 lb (0.03 kg) UL recognized File #E62437, CSA certifi ed File #LR35144e, CE

SH2B-05 Blade, DIN rail or surface mount 300V 10A Spring: SY4S-02F1;

Clip: SFA-101, SFA-202 Two 12 AWG 0.10 lb (0.05 kg) UL recognized File #E62437, SH3B-05 Blade, DIN rail or surface mount 300V 10A Spring: SH3B05F1;

Clip: SFA-101, SFA-202 Two 12 AWG 0.13 lb (0.06 kg) UL recognized File #E62437, SH4B-05 Blade, DIN rail or surface mount 300V 10A Spring: SH4B-02F1;

Clip: SFA-101, SFA-202 Two 12 AWG 0.16 lb (0.07 kg) UL recognized File #E62437, SR2P-05 8-Pin DIN rail or surface mount 300V 10A Spring: SR2B-02F1 (RR2P only);

Clip: SFA-203 (RTE-P1 only) Two 12 AWG 0.10 lb (0.05 kg) UL recognized File #E62437, SR2P-06 8-Pin, DIN rail or surface mount 300V 10A Spring: SR2B-02F1 (RR2P only);

Clip: SFA-202 (RTE-P1 only) Two 12 AWG 0.10 lb (0.05 kg) UL recognized File #E62437, SR3P-06 11-Pin, DIN rail or surface mount 300V 10A Spring: SR3B-02F1 (RR only);

Clip: SFA-202 (RTE-P2 only) Two 12 AWG 0.13 lb (0.06 kg) UL recognized File #E62437, SR3B-05 Blade, DIN rail or surface mount 300V 10A Spring: SR3B-02F1 (RR3PA only);

Clip: SFA-202 (RTE-P2 only) Two 12 AWG 0.14 lb (0.06 kg) UL recognized File #E62437, IDEC RELAY SOCKETS

SH, SJ, SR SERIES

The SH and SR Series of IDEC relay sockets are for use with the IDEC RH / RR Series relays and RTE Series timers. The SH and SR Series include both blade and pin style sockets and are available for one, two, three and four pole relays.

The SH and SR sockets can be DIN rail or surface mounted.

The SJ Series of IDEC relay sockets are for use with the IDEC RJ1S and RJ2S Series relays. They can be DIN rail or surface mounted.

• Use with IDEC RH / RR / RJ relays and RTE timers

• Screw terminals with captive wire clamp

• Surface or DIN rail mount

• UL recognized, CSA certifi ed and CE approved

SJ1S, SJ2S SH1B-05

SH2B-05 SH3B-05

SH4B-05 SR2P-05 SR2P-06 SR3P-06 SR3B-05

001-901-382-6084 International 888-397-5353 USA kele.com © 2012 Kele, Inc. All rights reserved. The Kele name and logo are registered trademarks of Kele, Inc.

TA

CT

IDEC RELAY SOCKETS

SH, SJ, SR SERIES

SH1B-05 Relay socket, SPDT blade type, DIN/surface mount SH1B-05C SH1B-05QT20 SH2B-05 Relay socket, DPDT blade type, DIN/surface mount SH2B-05C SH2B-05QT10 SH3B-05 Relay socket, 3PDT blade type, DIN/surface mount SH4B-05 Relay socket, 4PDT blade type, DIN/surface mount SH4B-05C SJ1S-05B Relay socket, SPDT blade type, DIN/surface mount SJ2S-05B Relay socket, DPDT blade type, DIN/surface mount SR2P-05 Relay socket, DPDT pin type, DIN/surface mount SR2P-06 Relay socket, DPDT pin type, DIN/surface mount SR3B-05 Relay socket, three-pole blade type, DIN/surface mount SR3P-06 Relay socket, 3PDT pin type, DIN/surface mount

14 13

0.32 (0.8)

0.66 (1.7)

0.63 (1.6)

0.63 (1.6)

0.78 (2.0)

0.10 (0.25)

0.57 (1.5)

0.98 (2.5)

1.12 (2.85)

2.62 (6.7)

1.83 (4.8)

0.16 dia.

(0.42)

2 Mounting Holes

0.16 dia

DIN

Rail

SH1B-05

0.86 (2.2)

1.03 (2.6)

1.03 (2.6)1.17

(3.0)

0.7 (1.88)

SH2B-05

1.25 (3.2)

(3.6)

1.56 (4.0)

SH3B-05

SJ1S

SJ1S,

SJ2S

SJ2S

4 5

0.6 (1.6) 0.2 (0.4)

0.1 (0.2)

1.2 (2.9)

2.8 (7.1)

1.4 (3.5)

1.9 (4.9)

2.2 (5.6)

SJ1S, SJ2S

1.65 (4.2)

1.81 (4.6)

1.81 (4.6)

1.97 (5.0)

2 Mounting Holes

0.16 dia (0.42)

(.25)

SH4B-05

1.40

1.14 (2.9)

1.14 (2.9)

0.64 (1.7)

0.78 (2.0)

1.25

2.03 (5.2)

1.28 (3.3)

0.9

0.16 dia. (0.42)

0.12

5 4

SR2P-05

1.56 (4.0)

1.3

(1.8)

1.0 (2.55)

2.34 (6.0)

0.97

0.04

5 4 3

7 8

SR2P-06

2.3 (5.9)

2.34 (6.0)

0.12

2 31

7 6

9 1110

8 5

(1.8)

1.0 (2.55)

1.05

SR3P-06

.07 (0.2)

0.16 dia.

0.31 (0.8) M3.5

Terminal Screw

(0.42)2.9

(7.6)

1.41

1.45 (3.7)

1.69 (4.3)

2.2 (5.6)

1.45 (3.7)

9 8

B A

SR3B-05

Sw itches &

Pilot Lights Signaling Lights

Relays & Sockets

Tim ers

Contactors Term inal Blocks Circuit Breakers

799800-262-IDEC (4332) • USA & Canada

RY/RMRelays & Sockets

RY/RM Series Miniature Relays

Key features:

•RY2 (3A), RY4 (5A), RM2 (5A)
•General purpose miniature relays
•3A or 5A contact capacity
•Wide variety of terminal styles and coil voltages meet a wide range of applications
•All 4PDT types have arc barriers.

Part Number Selection Part Number

Contact Model Plug-in Terminal PC Board Terminal Coil Voltage Code

DPDT (Slim) 3A Standard RY2S-U 0 RY2V-U 0

AC6V, AC12V, AC24V, AC110V, AC120V,

AC220V, AC240V

DC6V, DC12V, D24V, DC48V, DC110V

With Indicator RY2S-UL 0 RY2V-UL 0

With Check Button RY2S-UC 0

—With Indicator and Check Button RY2S-ULC 0

Top Bracket Mounting RY2S-UT 0

With Diode (DC coil only) RY2S-UD 0 RY2V-UD 0 DC6V, DC12V, DC24V, DC48V, DC110V

DPDT (Wide) 5A

Standard RM2S-U 0 RM2V-U 0

RYAC6V, AC12V, AC24V, AC110-120V, AC220-240V

DC6V, DC12V, DC24V, DC48V, DC100-110V

With Indicator RM2S-UL 0 RM2V-UL 0

With Check Button RM2S-UC 0

With Indicator and Check Button RM2S-ULC 0

Top Bracket Mounting RM2S-UT 0

With Diode (DC coil only) RM2S-UD 0

With Indicator and Diode (DC coil only) RM2S-ULD 0

4PDT 5A

Standard RY4S-U 0 RY4V-U 0

AC6V, AC12V, AC24V, AC110-120V,

AC220-240V

With Indicator RY4S-UL 0 RY4V-UL 0

With Check Button RY4S-UC 0

With Indicator and Check Button RY4S-ULC 0

Top Bracket Mounting RY4S-UT 0

With Diode (DC coil only) RY4S-UD 0

With Indicator and Diode (DC coil only) RY4S-ULD 0

Top mount models are designed to mount directly to a panel and do not require a socket.

Ordering Information When ordering, specify the Part No. and coil voltage code:

(example) RY4S-U AC110-120V Part No. Coil Voltage Code itc he s

P ilo t L ig ht

Si gn al g

Li gh ts Re la ys

S oc ke

Ti m er

Co nt ac to rs

Te rm

B lo ck

Ci rc ui t B re ak

RY/RM Relays & Sockets

800 www.IDEC.com

Relays Standard DIN Rail Mount

Finger-safe DIN Rail Mount Through Panel Mount PCB Mount

RY2S SY2S-05 SY2S-05C SY2S-51 SY2S-61

RM2 SM2S-05 SM2S-05C SM2S-51 SY4S-61

SY4S-62RY4S SY4S-05 SY4S-05C SY4S-51

Hold Down Springs & Clips

Appearance Item Relay For DIN Mount Socket

For Through Panel & PCB Mount Socket

Pullover Wire Spring

RY2S SY2S-02F1 SY4S-51F1

RM2

SY4S-51F1 SY4S-51F1

RY4S

Leaf Spring 1 (side latch)

RY2S

SFA-202 2 SFA-302

RM2, RY4S

Leaf Spring 1 (top latch)

RY2S

SFA-101 2 SFA-301RM2

RY4S

1. Not available for PCB mount socket SY4S-62.

2. Order 2 pieces per relay.

Accessories Item Appearance Use with Part No. Remarks

Aluminum DIN Rail (1 meter length)

All DIN rail sockets BNDN1000

The BNDN1000 is designed to accommodate DIN mount sockets.

Made of durable extruded aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard length is 39” (1,000mm).

DIN Rail End Stop DIN rail BNL5 9.1 mm wide.

Replacement Hold-Down Spring Anchor

Horseshoe clip for all DIN rail sockets Y778-011 For use on DIN rail mount socket when using pullover wire hold down spring. 2 pieces included with each socket.

801800-262-IDEC (4332) • USA & Canada

Specifications

Contact Model Standard Contact

RY2 - DPDT Slim RM2 - DPDT Wide RY4 - 4PDT

Contact Material Gold-plated silver Silver Gold-plated silver

Contact Resistance 1 50 mΩ maximum 30 mΩ maximum 50 mΩ maximum

Minimum Applicable Load 24V DC, 5 mA; 5V DC, 10 mA (reference value)

24V DC, 10 mA; 5V DC, 20 mA (reference value)

24V DC, 5 mA; 5V DC, 10 mA (reference value)

Operating Time 2 20 ms maximum

Release Time 2 20 ms maximum

Power Consumption (approx.)

AC: 1.1 VA (50 Hz), 1 VA (60 Hz)

DC: 0.8W

AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz)

DC: 0.9W

AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz)

DC: 0.9W

Insulation Resistance 100 MΩ minimum (500V DC megger)

Dielectric Strength

Between live and dead parts:

1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute

Between contact and coil:

Between contacts of different poles:

Between contacts of the same pole:

1000V AC, 1 minute 1000V AC, 1 minute 1000V AC, 1 minute

Operating Frequency Electrical: 1800 operations/h maximum Mechanical: 18,000 operations/h maximum

Vibration Resistance Damage limits: 10 to 55 Hz, amplitude 0.5 mm Operating extremes: 10 to 55 Hz, amplitude 0.5 mm

Shock Resistance Damage limits: 1000 m/s2

Operating extremes: 100 m/s2 (DPDT Slim), 200 m/s2 (4PDT, DPDT Wide)

Mechanical Life 50,000,000 operations

Electrical Life 200,000 operations (220V AC, 3A) 500,000 operations (220V AC, 5A) 100,000 operations (220V AC, 5A) 200,000 operations (220V AC, 3A)

Operating Temperature 3 –25 to +55°C (no freezing) –25 to +45°C (no freezing) –25 to +55°C (no freezing) 4

Operating Humidity 45 to 85% RH (no condensation)

Weight (approx.) 23g 35g 34g

Note: Above values are initial values.

1. Measured using 5V DC, 1A voltage drop method

2. Measured at the rated voltage (at 20°C), excluding contact bouncing Release time of relays with diode: 40 ms maximum

3. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating temperature range of relays with indicator or diode is –25 to +40°C.

4. When the total current of 4 contacts is less than 15A, the operating tem-perature range is –25 to +70°C.

802 www.IDEC.com

AC Coil Ratings

Voltage (V)

Rated Current (mA) ±15% at 20°C Coil Resistance (Ω) ±10% at 20°C

Operation Characteristics (against rated values at 20ºC)AC 50Hz AC 60Hz

Slim

DPDT Wide &

Max. Continuous Applied Voltage

Pickup

Dropout

6 170 240 150 200 18.8 9.4

110% 80% maximum 30% minimum

12 86 121 75 100 76.8 39.3

24 42 60.5 37 50 300 153

110 9.6 — 8.4 — 6,950 —

110-120 — 9.4-10.8 — 8.0-9.2 — 4,290

120 8.6 — 7.5 — 8,100 —

220 4.7 — 4.1 — 25,892 —

220-240 — 4.7-5.4 — 4.0-4.6 — 18,820

240 4.9 — 4.3 — 26,710 —

DC Coil Ratings

Voltage (V)

Rated Current (mA) ±15% at 20°C

Coil Resistance (Ω) ±10% at 20°C

Operation Characteristics (against rated values at 20ºC)

DPDT Slim DPDT Wide & 4PDT DPDT Slim DPDT Wide & 4PDT Max. Continuous Applied Voltage

Pickup

Dropout

6 128 150 47 40

110% 80% maximum 10% minimum

12 64 75 188 160

24 32 36.9 750 650

48 18 18.5 2,660 2,600

100-110 — 8.2-9.0 — 12,250

110 8 — 13,800 —

Contact Ratings UL Ratings Maximum Contact Capacity

Resistive General use

Wide 4PDT DPDT

Wide 4PDT

240V AC 3A 5A 5A 0.8A 2A 5A

120V AC — — — 1.5A 2.5A —

100V DC 0.2A 0.4A 0.2A 0.2A — 0.2A

30V DC 3A 5A 5A 3A — 5A

CSA Ratings

Resistive General use

Wide 4PDT DPDT

240V AC 3A 5A 5A 0.8A 2A 5A

120V AC 3A 5A — 1.5A 2.5A —

100V DC — — — 0.2A 0.4A 0.2A

30V DC 3A 5A 5A 1.5A 2.5A 1.5A

Contact Continuous Current

Allowable Contact Power Rated Load

Resistive Load Inductive Load Voltage (V) Res. Load Ind. Load

DPDT Slim

(RY2) 3A 660 VA AC

90W DC

176 VA AC

45W DC

110V AC 3A 1.5A

220V AC 3A 0.8A

30V DC 3A 1.5A

DPDT Wide

(RM2) 5A 1100VA AC

150W DC

440VA AC

75W DC

110V AC 5A 2.5A

220V AC 5A 2A

30V DC 5A 2.5A

4PDT (RY4) 5A 1200 VA AC

150W DC

288 VA AC

60W DC

240V AC 5A 1.2A

30V DC 5A 2A

Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms

TÜV Ratings

Voltage DPDT

240V AC 3A 5A 5A

30V DC 3A 5A 5A

AC: cos ø = 1.0, DC: L/R = 0 ms

803800-262-IDEC (4332) • USA & Canada

Socket Specifications Sockets Terminal Electrical Rating Wire Size Torque

Mount

SY2S-05 M3 screws with captive wire clamp 300V, 7A Maximum up to 2–#14AWG 5.5 - 9 in•lbs

SM2S-05 M3 screw with captive wire clamp 300V, 10A Maximum up to 2–#14AWG 5.5 - 9 in•lbs

SY4S-05 M3 screw with captive wire clamp 300V, 7A* Maximum up to 2–#14AWG 5.5 - 9 in•lbs

Finger-safe

Mount

SY2S-05C M3 screws with captive wire clamp, fingersafe 300V, 7A Maximum up to 2–#14AWG 5.5 - 9 in•lbs

SM2S-05C M3 screw with captive wire clamp, fingersafe 300V, 10A Maximum up to 2–#14AWG 5.5 - 9 in•lbs

SY4S-05C M3 screw with captive wire clamp, fingersafe 300V, 7A* Maximum up to 2–#14AWG 5.5 - 9 in•lbs

Through Panel Mount Socket

SY2S-51 Solder 250V, 7A — —

SM2S-51 Solder 250V, 10A — —

SY4S-51 Solder 250V, 7A* — —

PCB Mount Socket

SY2S-61 PCB Mount 300V, 7A — —

SY4S-61 PCB Mount 300V, 7A — —

SY4S-62 PCB Mount 250V, 7A — —

* When using only 2 poles of the 4-poles, the UL recognized current is 10A.

806 www.IDEC.com

Internal Connection (View from Bottom) Standard Type

DPDT Slim (RY2) DPDT Wide (RM2) 4PDT (RY4) With Check Button

Front Pushbutton

Contacts can be operated by pressing the check button.

With Indicator (-L type) DPDT Slim (RY2) DPDT Wide (RM2) 4PDT (RY4)

Coil Below 100V

AC/DC

24V AC/

When the relay is energized, the indicator goes on.

• An LED protection diode is not contained in DPDT relays for coils below 100V

DC.

• If coil polarity is reversed LED will not light.

100V and over

Coil 24V and over

With Diode (-D type) DPDT Slim (RY2) DPDT Wide (RM2) 4PDT (RY4)

Contains a diode to absorb the back emf gener-ated when the coil is de-energized. The release time is slightly longer.

• Diode Characteristics

Reverse withstand voltage: 1,000V Forward current: 1A

With Indicator and Diode (-LD type)

DPDT Wide (RM2) 4PDT (RY4) DPDT Wide (RM2) 4PDT (RY4)

24V DC

Coil 24V DC and over

(+)1413(–)

13(–) (+)14

Contains an LED indicator and a surge absorber.

807800-262-IDEC (4332) • USA & Canada

Dimensions (mm)

RY2S RY4S RM2S

SY2S-05: 61.5 (63.5) max., SY2S-51: 39.6 (41.6) max.

35.6 max. 5.4 14

.5

0.

Total length from panel surface including relay socket

Dimensions in the ( ) include a hold-down spring.3 × ø1.2 oblong hole

1 2

35.6 max. 6.4 21

Total length from the panel surface including relay socket SY4S-05: 61.5 (63.5) max., SY4S-51: 39.6 (41.6) max.

2.2 × ø1.2 oblong hole Dimensions in the ( ) include a hold-down spring.

35.6 max. 6.4 21

Total length from the panel surface including relay socket.

SM2S-05: 61.5 (63.5) max., SM2S-51: 39.6 (41.6) max.

Dimensions in the ( ) include a hold-down spring.

2.2 × ø1.2 hole

RY2V RY4V RM2V

35.6 max. 4 14 4.4

.7

4.

6.

7.

8 2.

60.5

8-ø1 holes

35.6 max. 4 21 4.4 4.4

4.4

6.6

0.5

14-ø1 holes

35.6 max. 4 21 13.2

15 6.

60.5

8-ø1 hole

RY2S-UT RY4S-UT RM2S-UT

14.5

3.5

35.6 max. 5.4

.2

6 4.

43 ¥ ø1.2 oblong hole

21.5

35.6 max. 6.4

42.

2.2 ¥ ø1.2 oblong hole

21.5

35.6 max. 6.4

.53843

2.2 ¥ ø1.2 hole

808 www.IDEC.com

Dimensions

Standard DIN Rail Mount Sockets

SY2S-05 SM2S-05

2 20

M3 Terminal

14.5

(BNDN)

31.5

Terminal Arrangement

2-ø4.2 Mounting Holes (or M4 Tapped Holes)

5.9 max.

4 max. 4.8 min.

ø3.2 min.

(Top View)

18.5

SY4S-05

18.5

12 11 10

4 3 2

Finger-safe DIN Rail Mount Sockets

SY2S-05C SM2S-05C

ø5

18.2

17.2

20 2

35.5

Ring terminals cannot be used.

ø5.5

Ring terminals cannot be used. (Top View)

SY4S-05C

ø5.5 18

12 11 10

4 3 2

(Top View)Ring terminals cannot be used.

NEW!

NTACTO

HUGE IN-STOCK INVENTORY, AVAILABLE TO SHIP SAME DAY kele.com 877-826-9037 USASeptember 2016

MODEL FULL-LOAD AMP (FLA) LOCKED-ROTOR AMP (LRA) RESISTIVE HP, SINGLE PHASE HP, THREE PHASE

DPC24A2D30

DPC01A2D30

DPC02A2D30

30 FLA @ 240-600 VAC 180 LRA @ 240/277 VAC

150 LRA @ 480 VAC

120 LRA @ 600 VAC

40A @ 240-600 VAC 2 hp @ 120 VAC 3 hp @ 240 VAC

DPC24A2D40

DPC01A2D40

40 FLA @ 240-600 VAC 240 LRA @ 240/277 VAC

200 LRA @ 480 VAC

160 LRA @ 600 VAC

50A @ 240-600 VAC 2 hp @ 120 VAC 3 hp @ 240 VAC

DPC24A3C30

DPC01A3C30

5 hp @ 240/277 VAC

DPC24A3C40

DPC01A3C40

40 FLA @ 240-600 VAC 240 LRA @ 240/277 VAC

50A @ 240-600 VAC 3 hp @ 120 VAC

7.5 hp @ 240/277 VAC

DPC24A3B50

DPC01A3B50

50 FLA @ 240-600 VAC 300 LRA @ 240 VAC

250 LRA @ 480 VAC

200 LRA @ 600 VAC

65A @ 240-600 VAC 3 hp @ 120 VAC

7.5 hp @ 200/208 VAC 10 hp @ 240 VAC

10 hp @ 200/208 VAC 10 hp @ 240/277 VAC 15 hp @ 480 VAC 20 hp @ 600 VAC 10 hp @ 200/208 VAC 10 hp @ 240/277 VAC 20 hp @ 480 VAC 25 hp @ 600 VAC 15 hp @ 200/208 VAC 15 hp @ 240 VAC 25 hp @ 480/600 VAC

DPC24A4A30

DPC01A4A30

5 hp @ 240/277 VAC

DPC24A4A40

DPC01A4A40

40 FLA @ 240-600 VAC

DPST-N.O.

DPST-N.O.

3PST-N.O.

DPC24A3B60

DPC01A3B60

60 FLA @ 240-600 VAC 360 LRA @ 240 VAC

300 LRA @ 480 VAC

240 LRA @ 600 VAC

75A @ 240-600 VAC 3 hp @ 120 VAC

7.5 hp @ 200/208 VAC 10 hp @ 240 VAC

25 hp @ 200/208 VAC 25 hp @ 240 VAC 30 hp @ 480/600 VAC

4PST-N.O.

4PST-N.O.

240 LRA @ 240/277 VAC

50A @ 240-600 VAC 3 hp @ 120 VAC

7.5 hp @ 240/277 VAC

15 hp @ 480 VAC

10 hp @ 480 VAC

POLES

DEFINITE PURPOSE CONTACTORS

DPC SERIES

The Hecheng Electrical DPC Series is an economical line of definite-purpose contactors designed to control electrical loads such as air conditioning, refrigeration compressor, motors, and resistance heaters.

• Two-, three-, and four-pole models

• Contact ratings from 30-60 FLA

• Optional auxiliary contacts on select models

CONTACT RATINGS

Two-pole Three-pole Four-pole

IEC 60947-4-1

Line Load Terminals Box lug or dual 0.25” quick connects Coil Terminals Dual 0.25” quick connects Auxiliary Contacts 10A, 1/3 hp @ 120/250 VAC 4A @

120 VAC for lamp load Wire Size 14-4 AWG

Operating Temperature -40° to 149°F (-40° to 65°C) Approvals UL recognized, File #E246810, CE certified Weight 1.5 lbs (0.68 Kg)

MODEL COIL VOLTAGE

(VAC)

INRUSH @ 50 Hz

(VA)

SEALED @ 50 Hz

INRUSH @ 60 Hz

SEALED @ 60 Hz

PULL-IN

DROP-OUT RANGE

DPC24A2D30, 40 24 31 6 28 5 18 6-15

DPC01A2D30, 40 120 31 6 28 5 88 20-70

DPC02A2D30 208/240 35 7 32 6 177 40-140

DPC24A3C30, 40 24 65 7.5 60 6 18 6-15

DPC01A3C30, 40 120 65 7.5 60 6 88 20-70

DPC24A3B50, 60 24 140 20 132 14 18 6-15

DPC01A3B50, 60 120 140 20 132 14 93 20-70

DPC24A4A30, 40 24 68 14 60 9 19.2 6-15

DPC01A4A30, 40 120 68 14 60 9 88 20-70

COIL RATINGS

NT

TO

TRY KELE'S UL-LISTED PANEL SHOPkele.com877-826-9037 USA September 2016

DEFINITE PURPOSE CONTACTORS

DPC SERIES

RELATED PRODUCTS

CN1C Auxiliary contact, (1) SPDT

MODEL

CONTACT AMP RATING

NUMBER

OF POLES

COIL

VOLTAGE (VAC)

DIMENSIONS in (cm) APPROX.

WEIGHT

lb (Kg)

Optional Aux.

Switch Inductive Full Load

Resistive Length Width Height

DPC24A2D30 30 40 2 24 3.29 (8.36) 2.0 (5.08) 2.61 (6.63) 0.6 (0.27) No

DPC01A2D30 30 40 2 120 3.29 (8.36) 2.0 (5.08) 2.61 (6.63) 0.6 (0.27 No

DPC02A2D30 30 40 2 208/240 3.29 (8.36) 2.0 (5.08) 2.61 (6.63) 0.6 (0.27 No

DPC24A2D40 40 50 2 24 3.29 (8.36) 2.0 (5.08) 2.61 (6.63) 0.6 (0.27 No

DPC01A2D40 40 50 2 120 3.29 (8.36) 2.0 (5.08) 2.61 (6.63) 0.6 (0.27 No

DPC24A3C30 30 40 3 24 3.30 (8.38) 2.90 (7.37) 3.0 (7.62) 1.0 (0.45) Yes

DPC01A3C30 30 40 3 120 3.30 (8.38) 2.90 (7.37) 3.0 (7.62) 1.0 (0.45) Yes

DPC24A3C40 40 50 3 24 3.30 (8.38) 2.90 (7.37) 3.0 (7.62) 1.0 (0.45) Yes

DPC01A3C40 40 50 3 120 3.30 (8.38) 2.90 (7.37) 3.0 (7.62) 1.0 (0.45) Yes

DPC24A3B50 50 65 3 24 4.06 (10.3) 3.19 (8.10) 3.56 (9.04) 2.0 (0.91) No

DPC01A3B50 50 65 3 120 4.06 (10.3) 3.19 (8.10) 3.56 (9.04) 2.0 (0.91) No

DPC24A3B60 60 75 3 24 4.06 (10.3) 3.19 (8.10) 3.56 (9.04) 2.0 (0.91) No

DPC01A3B60 60 75 3 120 4.06 (10.3) 3.19 (8.10) 3.56 (9.04) 2.0 (0.91) No

DPC24A4A30 30 40 4 24 3.42 (8.69) 2.75 (7.0) 3.03 (7.7) 1.5 (0.68) Yes

DPC01A4A30 30 40 4 120 3.42 (8.69) 2.75 (7.0) 3.03 (7.7) 1.5 (0.68) Yes

DPC24A4A40 40 50 4 24 3.42 (8.69) 2.75 (7.0) 3.03 (7.7) 1.5 (0.68) Yes

DPC01A4A40 40 50 4 120 3.42 (8.69) 2.75 (7.0) 3.03 (7.7) 1.5 (0.68) Yes

POWER MONITORING & PROTECTION

PO

W

ER M

NITO

RING & PRO

TECTIO

GROWING SELECTION AVAILABLE ON KELE.COM kele.com 877-826-9037 USASeptember 2016

CURRENT-OPERATED SWITCHES & TRANSDUCERS

RIBXG, RIBXK, RIBXK420 SERIES

RIBXK, RIBXG SERIES

Monitored AC Current

RIBXKF, RIBXKTF 0.25-150A

RIBXKA, RIBXKTA 0.5-150A

RIBXGF, RIBXGTF 0.35-150A

RIBXGA, RIBXGTA 0.75-150A

Relay Trip Point RIBXKF, RIBXKTF 0.25A, fixed RIBXKA, RIBXKTA 0.5-150A, adjustable RIBXGF, RIBXGTF 0.35A, fixed RIBXGFL, RIBXGTFL 0.75A, fixed RIBXGA, RIBXGTA 0.75-150A, adjustable Relay Type Solid state, normally open Relay Rating 30 VAC/VDC, 0.4A maximum Off State Leakage <30 µA @ 30 VAC/VDC On State Voltage Drop <0.3 VAC/VDC @ 0.1A

<1.6 VAC/VDC @ 0.4A

RIBXK420 SERIES

Supply Voltage 24 VDC Output 4-20 mA @ 600Ω, 30 mA maximum Accuracy ±5% FS Linearity ±1% FS Input Range 20, 50, or 100A General Frequency Suitable for most VFD applications Maximum Sensed Voltage 600 VAC Terminations 16" (40.6 cm), 18 AWG, 600V wires or terminals for 14-22 AWG Operating Temperature -30° to 140°F (-34.4° to 60°C) Weight 0.3 lb (0.13 Kg) Approvals UL916, UL864 UL File #S7312, CE, RoHs

0.50 (1.27)

1.46 (3.7)

1.86 (4.73)

1.508 (3.83)

1.008 (2.56)

Ratcheting Cam

Clamp

Removable Mounting Tab

RIBXK420 RIBXK , RIBXG

RIBXK

(cm)

24 VDC

Power Supply

(black)

(red) BAS Input or Other

4-20 mA Load

2.52 (6.4)

2.00 (5.1)

1.10 (2.8)

1.75 (4.4)

Load Wire Opening

0.52 x 0.52 (1.3 x 1.3)

LEDs

Trip

Adjust

Wire Clamp

Removable Mounting Tab

Wh/Yel

Load Wire

Load Wire

Normally open solid-state switch is not polarity sensitive

Models with Screw Terminals

Models with Wire Leads

RIBXG

The Functional Devices RIBXK, RIBXG, RIBXK420 Series include both current-operated switches and current transducers. Solid-core and split-core current-operated switch models have a solid-state switch that operates when the current level sensed by the internal current transformer exceeds a fixed or adjustable set point. Solid-core current transducer models output a 4-20 mA signal proportional to the line current being monitored.

• Solid- and split-core switch models have fixed (go/no go) or adjustable trip points

• Solid-core transducer models have a 4-20 mA output

• Low cost

• Ratcheting cam clamp to secure switch to wire

• Removable mounting tab

RIBXKF Solid-core current-operated switch, wire leads, fixed-trip RIBXKTF Solid-core current-operated switch, terminals, fixed-trip RIBXKA Solid-core current-operated switch, wire leads, adjustable-trip RIBXKTA Solid-core current-operated switch, terminals, adjustable-trip RIBXK420-20 Solid-core current transducer, 0-20A RIBXK420-50 Solid-core current transducer, 0-50A RIBXK420-100 Solid-core current transducer, 0-100A RIBXGF Split-core current-operated switch, fixed 0.35A trip, wire leads RIBXGTF Split-core current-operated switch, fixed 0.35A trip, terminal strip RIBXGFL Split-core current-operated switch, fixed 0.75A trip, wire leads, LEDs RIBXGTFL Split-core current-operated switch, fixed 0.75A trip, terminal strip, LEDs RIBXGA Split-core current-operated switch, adjustable trip, wire leads, LEDs RIBXGTA Split-core current-operated switch, adjustable trip, terminal strip, LEDs

RIBXKF

RIBXKA

RIBXGTF

RIBXK420

RIBXKTF

RIBXKTA

Automation Server Enables StruxureWare Building Operation v1.3

A StruxureWareTM Building Operation server is the core of the system and performs key functionality, such as control logic, trend logging, and alarm supervision. The Automation Server software is pre-loaded on Schneider Electric supplied hardware that supports communication and connectivity to the I/O and field buses. The distributed intelligence of the Automation Server ensures fault tolerance in the system and provides a fully featured user interface through WorkStation and WebStation.

Make the most of your energy SM

Compatible

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings

SDS-AUTOMATIONSERVER-A4.BU.N.EN.11.2012.0.00.CC

ch ne id

E le ct ric . A ll rig se rv ed

Features

The Automation Server is a powerful device that can act as a standalone StruxureWare Building Operation server and also control I/O modules and monitor and manage field bus devices.

In a small installation, the embedded Automation Server acts as a stand-alone StruxureWare Building Operation server, mounted with its I/O modules in a small footprint. In medium and large installations, functionality is distributed over multiple Automation Servers that communicate over TCP/IP.

Communications hub Capable of coordinating traffic from above and below its location, the Automation Server can deliver data directly to you or to other servers throughout the site. The Automation Server can run multiple control programs, manage local I/O, alarms, and users, handle scheduling and logging, and communicate using a variety of protocols. Because of this, most parts of the system function autonomously and will continue to run as a whole even if communication fails or individual servers or devices go offline.

Variety of connectivity options The Automation Server has numerous ports that enable it to communicate with a wide range of protocols, devices, and servers. The Automation Server has one 10/100 Ethernet port, two RS-485 ports, and one built-in I/O bus port. Additionally, there are two USB host ports and one USB device port. The device port allows you to upgrade and interact with the Automation Server using the Device Administrator.

WorkStation/WebStation interface Through any client, the user experience is similar regardless of which StruxureWare Building Operation server the user is logged on to. The user can log directly on to an Automation Server to engineer, commission, supervise, and monitor the Automation Server as well as its attached I/O modules and field bus devices. See the WorkStation and WebStation data sheets for additional information.

Native support for open protocols One of the cornerstones of StruxureWare Building Operation is support for open standards.

Native BTL-listed BACnet support The Automation Server communicates directly to BACnet/IP and BACnet MS/ TP networks. Compliant with ASHRAE 135-2004, the Automation Server is BTL-listed as a BACnet Building Controller (B-BC)*, the most advanced BACnet Device Profile and as a BACnet Operator Workstation (B-OWS)*.

This capability provides access to the full range of BACnet devices from Schneider Electric and other vendors. The Automation Server can also serve as a BACnet Broadcast Management Device (BBMD) to facilitate BACnet systems that span multiple IP networks.

*See the BTL Product Catalog for up-to-date details on BTL listed firmware revisions: http://www.bacnetinternational.net/btl/index.php?m=20

PrOduCT AT A GLANCE

• Communications hub

• Variety of connectivity options

• WorkStation/WebStation interface

• Native support for open protocols – BACnet, LonWorks and Modbus

• Web Services support

• EcoStruxure Web Services support

• Scalable custom configurations

• Two programming options

• 4 GB of memory for data and backup

• IT friendly and secure

• Hot-connect / Hot-swap

• Patented two-piece design

• Auto-addressing

• Simple dIN-rail installation

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings

Features (continued)

Native LonWorks support The Automation Server has a built in FTT-10 port for integrated LonWorks functionality to enable access to any Schneider Electric LonWorks field controller or third-party LonWorks devices.

Lonworks networks can be commissioned, bound, and configured from the Automation Server using the built-in LonWorks Network Management Tool. No third-party tools are needed. A protocol analyzer with powerful debugging and network quality monitoring features is also included.

Native Modbus support The Automation Server natively integrates Modbus RS-485 master and slave configurations, as well as TCP client and server. This allows full access to third-party products and the range of Schneider Electric products that communicate on the Modbus protocol, such as power meters, UPS, circuit breakers, and lighting controllers.

Web Services support The Automation Server supports the use of Generic Web Services based on open standards such as SOAP and REST to consume data into StruxureWare Building Operation. Use incoming third-party data (e.g. temperature forecast, energy cost) over the Web to determine site modes, scheduling and programming.

EcoStruxure Web Services support EcoStruxure Web Services, Schneider Electric’s Web Services standard, is natively supported in the Automation Server. EcoStruxure Web Services offers extra features between compliant systems whether within Schneider Electric or authorized third-party systems, including system directory browsing, read/write of current values, alarm receipt and acknowledgement, and historical trend log data. EcoStruxure Web Services is secure.

User name and password are required to log on to the system.

Scalable custom configurations The Automation Server and its family of I/O modules were designed to meet the unique needs of each installation. Depending on the configuration, each Automation Server can control up to 464 I/O points. Because power and communications are delivered along a common bus, multiple modules can be plugged together without tools in a simple one-step process using the built-in connectors.

Two programming options Unique to the industry, the Automation Server has both Script and Function Block programming options. This flexibility ensures that the best programming method can be selected for the application.

4 GB of memory for data and backup The Automation Server has an available capacity of 4 GB of memory. This represents 2 GB for application and historical data and 2 GB dedicated for backup storage. This ensures that all data is safe from damage, loss, or unintended edits.

Users can also manually back up or restore the Automation Server to a storage location on a PC or network. Through the Enterprise Server, users have the ability to perform scheduled backups of associated Automation Servers to network storage for even greater levels of protection.

IT friendly and secure The Automation Server communicates using networking standards, such as DHCP, HTTP, and HTTPS (see sidebar for more). This makes installation easy, management simple, and transactions secure.

Hot-connect / Hot-swap Because critical applications require 24-hour operation, Schneider Electric designed the entire family of I/O modules for hot-connection of terminal bases and hot-swapping of modules to and from their bases. This design ensures continuous power and communication during many service operations.

Patented two-piece design Each module can be separated from its terminal base to allow the site to be wired prior to the installation of the electronics. The patented locking mechanism serves as handles for removing the module from its base. All critical components have a protective cover that permits natural convection cooling to occur.

Auto-addressing The auto-addressing feature eliminates the need for setting DIP switches or pressing commission buttons. With the Automation Server family, each I/O module automatically knows its order in the chain and assigns itself accordingly.

Simple DIN-rail installation Fasteners easily snap into a locked position for panel installation. The fastener has a quick-release feature for easy DIN rail removal.

Supported Protocols

• IP addressing

• TCP communications

• dHCP / dNS for rapid deployment and lookup of addresses

• HTTP/HTTPS - Internet access through firewalls, enabling for remote monitoring and control

• NTP (Network Time Protocol) for time synchronization throughout the system

• SMTP enables sending email messages

3.

3.

November 2012 gg

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings

All brand names, trademarks, and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice.

v1.3 Specifications

Specifications

AS-L

LO

-2

LO

-1

TP/FTRS-485

h ie ld

R

T

V

X

/R

Operator Panel

LON

F a c ry

1 2 3 4 5 6 7 8 9 10 11 12

The connection cable for these USB ports must not exceed 3 m (10 ft).

The connection cable for this USB port must not exceed 3 m (10 ft).

Host 10/100

Ethernet

13 15 16 19

.3

V

RS-485

Com A Com B

Add-on options

SW-EWS-1, EcoStruxure Web Services

(run-time) option – Consume only for one Automation Server, no mainte-nance

P/N: SXWSWEWSX00001

SW-EWS-2, EcoStruxure Web Services

(run-time) option – Serve & Consume for one Automation Server, no maintenance

P/N: SXWSWEWSX00002

SW-EWS-3, EcoStruxure Web Services

(run-time) option – Serve & Consume, plus Historical trend log data for one

Automation Server, no maintenance

P/N: SXWSWEWSX00003

SW-GWS-1, Web Services (Generic

Consume) option for one Automation

Server, no maintenance

P/N: SXWSWGWSX00001

Connectors

USB 1 device and 2 host ports

BACnet

BACnet/IP and MS/TP

BTL B-BC (BACnet Building Controller)*

BTL B-OWS (BACnet Operator

Workstation)*

WSPCert

*Specific firmwares versions may be required for BTL Listing status see: http:// www.bacnetinternational.net/btl/index.

php?m=20

LonWorks TP/FT-10

COM A 2-wire RS-485

COM B 2-wire RS-485 and 3.3 VDC

I/O Modules RS-485

TCP

Binary, port configurable, default 4444

HTTP

Non-binary, port configurable, default 80

HTTPS

Encrypted supporting SSL 1.0, 2.0, 3.0 and TSL 1.0, port configurable default 443

SMTP

Email sending, port configurable, default 25

CPU

Frequency 160 MHz

SDRAM 128 MB

Flash memory 4 GB

Part numbers

P/N: SXWAUTSVR10001

TB-AS-W1, Terminal Base for

(Required for each Automation

Server)

P/N: SXWTBASW110001

Electrical

DC input

Nominal voltage

24 VDC

Power consumption

Max. 7 W

Mechanical

Enclosure

Eco Friendly ABS/PC

Enclosure rating

IP 20

Plastic rating

UL94-5VB rated plastic

Dimensions (including terminal base)

90 W x 114 H x 64 D mm

(3.6 W x 4.5 H x 2.5 D in.)

Weight (including terminal base)

0.294 kg (0.65 lb)

Weight (excluding terminal base)

0.194 kg (0.43 lb)

Installation DIN-rail or panel installation

Operation environment

Ambient temperature, operating

0 °C to 50 °C (32 °F to 122 °F)

Ambient temperature, storage

–20 °C to +70 °C (–4 °F to +158 °F)

Humidity Max. 95 % RH (non-condensing)

Agency compliances

Emission

C-Tick; EN 61000-6-3;

FCC Part 15, Sub-part B, Class B

Immunity EN 61000-6-2

Safety UL 916 C-UL US Listed

Real-Time Clock backup

30 days

Communications

Ethernet LAN interface

10/100 Mbit/s; twisted pair cable with RJ-45 connector

StruxureWareTM Building Operation

AS PICS

Product Implementation Conformance Statement

Date 22 August 2012

Vendor name Schneider Electric

Vendor ID 10

Website www.Schneider-Electric.com/buildings

Range name StruxureWare Building Operation

Product name Automation Server

Product model number AS

Application software version N/A

Firmware revision 1.3

Base ASHRAE standard 135-2004-d,e,f

BACnet Protocol version 1

BACnet Protocol revision 6

Product description

The Automation Server is a native BACnet/IP protocol operator workstation and controller with a built-in web server and expandable Input/Output through the use of expansion modules. It has 2 serial ports, one of which may be used to communicate with MS/TP controller devices. The Automation Server also serves as a BACnet protocol router and BACnet/ IP Broadcast Management Device (BBMD). It performs BACnet routing functions among attached MS/TP networks.

The Automation Server also natively supports other protocols, such as LonWorks, Modbus, and Web Services, and can be used as a gateway device to exchange values between protocols.

Note: Requires StruxureWare Workstation P/N SW-STATION for user interface.

StruxureWare has been designed to • strictly comply with the ASHRAE BACnet standard.

BACnet enables integration between •

Devices designed for a wide variety of applications.

Natively supports BACnet, LonWorks, •

Modbus, and Web Services, and can serve as a gateway between protocols

This Protocol Implementation Confor-• mance Statement (PICS) document details the BACnet Interoperability

Building Blocks that are supported in

StruxureWare.

n e r ri c.

A ri r d

PP-AS-PICS-US.BU.N.EN.08.2012. August 2012 BAS

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings

All brand names, trademarks and registered marks are the property of their respective owners. Information contained within this document is subject to change without notice.

AS

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

Device Profi le Support

Controller Profi le:

BACnet Building Controller (B-BC) X

BACnet Advanced Application Controller (B-AAC)

BACnet Application Specifi c Controller (B-ASC)

BACnet Smart Actuator (B-SA)

BACnet Smart Sensor (B-SS)

Operator Profi le:

BACnet Advanced Operator Workstation (B-AWS)

BACnet Operator Workstation (B-OWS) X

BACnet Operator Display (B-OD)

Segmentation Capability

Segmentation Supported Window

Size

Able to transmit segmented messages X 1

Able to receive segmented messages X 1

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

Data Link Layer and Routing Options

Data Link Supported Data Rates Router for Data Link

BACnet/IP X Hardware dependent

Ethernet - ISO 8802_3

MS/TP master X 9600, 19200, 38400, 76800

Kbit/s

MS/TP slave

Zigbee

ARCnet - ANSI/ATA 878.1

RS-485 ANSI/ATA 878.1

LonTalk TP/FT - 10

LonTalk/IP

Point-to-Point EIA 232

Point-to-Point - modem

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

Other Networking Options

Networking Option Supported

Static Device Binding Supported

Annex H, BACnet Tunneling Router over IP

BACnet Broadcast Management Device (BBMD) X

BBMD supports registration by foreign device X

Device support registration as foreign device X

Character Sets Supported

Character Sets Supported

ANSI X3.4 X

ISO 8859-1 X

ISO 10646 (USC-2) X

ISO 10646 (UCS-4) X

IBM/Microsoft DBCS

JIS C 6226

Note: For messages received in UTF-8 encoding, responses are transmitted with the narrowest character set for optimal interoperability.

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

DS-RP-A ReadProperty-A x x x x x

DS-RP-B ReadProperty-B x x x x x x x x x

DS-RPM-A ReadPropertyMultiple-A x x x x

DS-RPM-B ReadPropertyMultiple-B x x x

DS-RPC-A ReadPropertyConditional-A

DS-RPC-B ReadPropertyConditional-B x

DS-WP-A WriteProperty-A x x x x x

DS-WP-B WriteProperty-B x x x x x

DS-WPM-A WritePropertyMultiple-A x x x

DS-WPM-B WritePropertyMultiple-B x x x

DS-COV-A COV-A x

DS-COV-B COV-B x

DS-COVP-A COVP-A

DS-COVP-B COVP-B

DS-COVU-A COV-Unsolicited-A

DS-COVU-B COV-Unsolicited-B

DS-V-A View-A x x x

DS-M-A Modify-A x x x

DS-AV-A Advanced View-A x

DS-AM-A Advanced Modify-A x

BACnet Interoperability Building Blocks (BIBBs) Support

BIBB Description

BACnet Standard ro u o fo an ce

Data Sharing

-A

-O

D

-B

-S

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

AE-N-A Notifi cation-A x x x

AE-N-I-B Notifi cation Internal-B x x x

AE-N-E-B Notifi cation External-B

AE-ACK-A ACK-A x x x

AE-ACK-B ACK-B x x x

AE-ASUM-A Summary-A x

AE-ASUM-B Alarm Summary-B

AE-ESUM-A Enrollment Summary-A x

AE-ESUM-B Enrollment Summary-B x x

AE-INFO-A Information-A x

AE-INFO-B Information-B x x x

AE-LS-A LifeSafety-A

AE-LS-B LifeSafety-B

AE-AS-A Alarm Summary-A x x x

AE-VN-A View Notifi cation-A x x x

AE-VM-A View Modify-A x x

AE-AVM-A Advanced View Modify-A x

AE-AVN-A

Advanced View Notifi cations-A x

AE-ELVM-A

Event Log View and Modify-A x1

Alarms and Events

1 Not required for devices claiming conformance to a protocol revision less than 7.

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

T-VMT-I-B

Viewing and Modifying Trends Internal-B x x

T-VMT-E-B

Viewing and Modifying Trends External-B

T-ATR-A

Automated Trend Retrieval-A

T-ATR-B

Automated Trend Retrieval-B

T-V-A View-A x x

T-A-A Archiving-A x

T-AVM-A

Advanced View and Modify-A

SCHED-I-B Scheduling - Internal-B x x

SCHED-E-B Scheduling - External-B x x

SCH-VM-A Scheduling - View Modify x x

SCH-AVM-A

Scheduling - Advanced View Modify

SCHED-WS-A

Scheduling - Weekly Schedule-A

SCHED-WS-I-B

Scheduling Weekly Schedule Internal-B

SCHED-R-B Scheduling - Readonly-B

Schedules

Trends

Note: The SCHED-A BACnet interoperability building block was removed from the BACnet Standard.

Note: The T-VMT-A BACnet interoperability building block was removed from the BACnet Standard.

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

DM-DDB-A Dynamic Device Binding-A x x x x x

DM-DDB-B Dynamic Device Binding-B x x x x x x x1 x1 x

DM-DOB-A Dynamic Object Binding-A

DM-DOB-B Dynamic Object Binding-B x x x x x x x1 x1 x

DM-DCC-A

DeviceCommunication Control-A

DM-DCC-B

DeviceCommunication Control-B x x x x

DM-PT-A Private Transfer-A

DM-PT-B Private Transfer-B

DM-TM-A Text Message-A

DM-TM-B Text Message-B

DM-TS-A TimeSynchronization-A x

DM-TS-B TimeSynchronization-B x x x x

DM-UTC-A UTCTimeSynchronization-A

DM-UTC-B UTCTimeSynchronization-B x x x

DM-RD-A ReinitializeDevice-A x x

DM-RD-B ReinitializeDevice-B x x x x

DM-BR-A Backup and Restore-A x x

DM-BR-B Backup and Restore-B x x

DM-R-A Restart-A

DM-R-B Restart-B

DM-LM-A List Manipulation-A

DM-LM-B List Manipulation-B

DM-OCD-A

Object Creation and Deletion-A

DM-OCD-B

Object Creation and Deletion-B

Device Management

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

DM-VT-A Virtual Terminal-A

DM-VT-B Virtual Terminal-B

DM-ANM-A

Automatic Network Mapping-A

DM-ADM-A

Automatic Device Mapping-A

DM-ATS-A

Automatic Time Synchronization

DM-MTS-A

Manual Time Synchronization-A x x x

Device Management (continued)

1 Not required if the device is a BACnet MS/TP Slave.

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

NM-CE-A Connection Establishment-A

NM-CE-B Connection Establishment-B

NM-RC-A Router Confi guration-A

NM-RC-B Router Confi guration-B x

Network Management

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

23 Accumulator P P P P P

0 Analog Input P P x P P

1 Analog Ouput P P x P P

2 Analog Value P P x x x

18 Averaging P P P P P

3 Binary Input P P x P P

4 Binary Output P P x P P

5 Binary Value P P x x x

6 Calendar P P x x x

7 Command P P P P P

8 Device x x x x x x x x x

9 Event Enrollment P P x x x

10 File P x P P

11 Group P

21 Life Safety Point

22 Life Safety Zone

12 Loop P P x x x

13 Multi-state Input P P x P P

14 Multi-state Output P P x P P

19 Multi-state Value P P x x x

15 Notifi cation Class P P x x x

16 Program P P x P P

24 Pulse Converter P P P P P

17 Schedule P P x x x

20 Trend Log P P x x x

30 Access Door

25 Event Log P

28 Load Control P P P P P

29 Structured View P

27 Trend Log Multiple P

32 Access Credential

Supported BACnet Object Types

ID Description C at ab el et

Product ConformanceBACnet Standard

Supported

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

33 Access Point

34 Access Rights

35 Access User

36 Access Zone

37 Credential Data Input

26 Global Group P

Supported BACnet Object Types (continued)

ID Description C at el et

Product ConformanceBACnet Standard

Supported

Note: P indicates ‘‘Proxy Only,’’ which means that the object is only supported by Workstation.

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

Accumulator

75 object-identifi er R Object ID P

77 object-name R BACnet name P P

79 object-type R BACnet type P

85 present-value R1 Value P P

28 description O Description P P

31 device-type O Device type P P

111 status-fl ags R Status fl ags P

36 event-state R Event state P

103 reliability O Reliability P

81 out-of-service R Out of service P P

186 scale R

117 units R

188 prescale O

65 max-pres-value R Maximum value P P

192 value-change-time O2 Value change time P

190 value-before-change O2, 3 Value before change P P

191 value-set O2, 3 Value set P P

184 logging-record O

183 logging-object O

186 pulse-rate O1, 4 Pulse rate P P

45 high-limit O4 Upper limit P P

59 low-limit O4 Lower limit P P

182 limit-monitoring-interval O4 Limit Monitoring interval

P P

17 notifi cation-class O4 BACnet notifi cation P P

113 time-delay O4 Time delay P P

52 limit-enable O4 Limit enable P P

35 event-enable O4 Event enable P P

ID

eq rit property name R ea da bl

Internal device property nameO pt io na l

Accumulator (proxy)

StruxureWare Device

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

0 acked-transitions O4 Acknowledged transitions

72 notify-type O4 Notify type P P

130 event-time-stamps O To-off-normal time To-fault time To-normal time

168 profi le-name O Profi le name P

1 This property is required to be writable when out-of-service is TRUE.

2 These properties are required if either Value_Before_Change or Value_Set is writable.

3 Either Value_Before_Change or Value_Set may be writable, but not both.

4 These properties are required if the object supports intrinsic reporting.

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings ©

Analog Input

2 This property is required if the object supports COV reporting.

3 These properties are required if the object supports intrinsic reporting.

75 object-identifi er R Object ID R

77 object-name R…