MS 022 Louvers and Color Chart.pdf

PDF 675 KB Posted

Attached to
Repair Maintenance Shop BLDG 8040
Solicitation number
FA4661-21-R-0001
Issued by

View the file

Other files

File Type Posted
AF Form 3065 Dyess Progress Report 42 Gov.pdf PDF
12-0053 Addendum Four - New Contractor (11-19-20) v2.doc DOC document
12-0053 Addendum Three - New Contractor (11-9-20).pdf PDF
Solicitation Amendment FA466121R00010001 SF 30.pdf PDF
12-0053 Attachment C - Contractor Pricing Breakdown 11.29.16.xlsx XLSX spreadsheet
MS 004 Staging Plan.pdf PDF
MS 039 HM Doors Frames and Hardware.pdf PDF
MS 026 Cove Base Submittal.pdf PDF
MS 032 Concrete Vapor Barrier.pdf PDF
MS 042A Overhead Coiling Doors.pdf PDF
MS 030 Steel Shop Drawings.pdf PDF
MS 024 MBCI Panel Roof and Color Chart.pdf PDF
MS 037 MBCI and Welding Certifications.pdf PDF
AF Form 3065 Dyess Progress Report 42 Gov.pdf PDF
MS 044 Casework.pdf PDF
MS 079 Radius Bullnose for Doorways.pdf PDF
MS 007 Mech and Plumb Consumables.pdf PDF
MS 027-028 Metal Slat Fencing - Color.pdf PDF
MS 011 Fire Alarm and Mass Notification MS 005a.pdf PDF
MS 025 VCT.pdf PDF
MS 070 Water Meter Specifications.pdf PDF
MS 073 Breakroom Sink Type and Color.pdf PDF
MS 031A Toilet Partions and Accessories.pdf PDF
MS 016 HVAC Controls.pdf PDF
MS 055 South Structural Steel.pdf PDF
MS 006 Mech and Plumb.pdf PDF
MS 008 Abatement Plan.pdf PDF
MS 069 Sidewall Sprinkler Head.pdf PDF
MS 076 Backflow Preventer.pdf PDF
MS 064 Dryvit Backstop Air Barrier.pdf PDF
MS 021 HVAC.pdf PDF
MS 050 Welder Certification.pdf PDF
MS 083 Aerospace Air Shower Substitution.pdf PDF
MS 030 Steel Shop Drawings Page 2.pdf PDF
MS 029 Anchor Rod Shop Drawings and Details.pdf PDF
MS 001 QC Plan.pdf PDF
MS 065 Concrete Test Reports.pdf PDF
MS 020A Electrical Transformer.pdf PDF
MS 041 Toilet Accessories and Fire Ext.pdf PDF
MS 035 Geotech Compaction Testing.pdf PDF
MS 078 078A Overhead Doors Warranty.pdf PDF
MS 023 Metal Panels.pdf PDF
MS 047 28 Day Concrete Test Results.pdf PDF
MS 061 Masonry Sealant Substitution.pdf PDF
MS 066 Roof Flashing.pdf PDF
REF 12 0053 PR 42 Thru 09 30 2019.xlsx XLSX spreadsheet
MS 010 Insulation.pdf PDF
MS 067 Steel Building Certifications.pdf PDF
MS 052 CMU Specs and Certs.pdf PDF
MS 036 MBCI Panels.pdf PDF
Show 40 more

Latest 50 of 163 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

4" deep • 45° J-Blade model SFJ-445 galvannealed steel louver

Equipment Schedule

Options

Accessories: Clip Angles Construction: 16 Gauge Galvannealed, Mechanically Fastened

Dimensions: Nominal Finish: Baked Enamel Finish Standard

Color-TBD From Chart

Frame: 1-1/2" Flange Screen: Screen 1- Bird Screen Aluminum

(1/2" x 0.063" Wire Mesh)

Rear/Interior Mount, Mill Finish

LocPosModelQty

Section Qty

W x H

Measured Opening

Louver Size

Rough Opening Size

QtyTag

Actuator

12 x 12L1 & L2 2 11.5 x 11.5 1 x 1

Project:

Addendum #:

Location:

Submitted By:

Architect:

Engineer:

Contractor:

Date: December 22, 2017

, Page 1 of 1

Dyess Bldg 8040

Note: Unless otherwise indicated, dimensions shown are in INCHES.Submitted By:

model SFJ-445 galvannealed steel louver

4" deep • 45° J-blade s s S

F J lg (0

3/

Application The SFJ-445 formed steel louver is designed for intake and exhaust application where protection against water infiltration is not critical. The SFJ-445 is available in a wide array of painted finishes including custom color matching.

Standard Construction Material: Galvannealed steel.

Frame: 4" deep 20 ga. thick (102 1) channel.

Blades: 45° 20 ga. (1) thick J-style.

Screen: 1/2" 0.063" (12.7 1.6) expanded and flattened aluminum.

Mullion: Visible.

Minimum Size: 12" 12" (305 305)

Maximum Size: Single section: 60" 120" (1524 3048) 120" 60" (3048 1524)

Multiple section: Unlimited

POTTORFF® 5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com

Information is subject to change without notice or obligation. NOTE: Dimensions in parentheses ( ) are millimeters.

Ratings Free Area: [48" 48" (1222 1222) unit]: 7.7 ft2 (0.72 m2)

48.0%

Performance @ Beginning Point of Water Penetration Free Area Velocity: 775 fpm (3.94 m/s)

Air Volume Delivered: 5,991 cfm (2.83 m3/s)

Pressure Loss: 0.13 in.wg. (32 Pa)

Velocity @ 0.15 in.wg. Pressure Loss: 840 fpm (4.26 m/s)

Design Load: 30 psf

W*

H*

4" (102)

4-5/8" (117)

Model SFJ-445 (standard)

*Louver dimensions furnished approximately 1/2" (13) undersize.

Vertical Section †Screen adds approximately

3/16" (5) to louver depth.

Horizontal Mullion

Mullion Cover (supplied loose for field installation)

Flange Frame (optional)

1-1/2" (38)

Vertical Mullion p d

S

J

(0 2/

Performance Data

POTTORFF® 5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com

Information is subject to change without notice or obligation. NOTE: Dimensions in parentheses ( ) are millimeters.

Water Penetration Beginning Point of Water Penetration = 775 fpm

Water Penetration AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48" 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions.

12 18 24 30 36 42 48 54 60 66 72 78 84 90 96

12 0.2 0.3 0.5 0.6 0.7 0.8 1.0 1.1 1.2 1.3 1.5 1.6 1.7 1.8 2.0

18 0.5 0.8 1.1 1.4 1.6 1.9 2.2 2.5 2.8 3.1 3.3 3.6 3.9 4.9 4.5

24 0.8 1.2 1.7 2.1 2.6 3.0 3.5 3.9 4.3 4.8 5.2 5.7 6.1 6.6 7.0

30 0.9 1.4 1.9 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.1 6.6 7.1 7.6 8.1

36 1.2 1.9 2.5 3.2 3.9 4.6 5.2 5.9 6.6 7.3 7.9 8.6 9.3 10.0 10.7

42 1.5 2.3 3.1 4.0 4.8 5.7 6.5 7.3 8.2 9.0 9.8 10.7 11.5 12.3 13.2

48 1.7 2.7 3.7 4.7 5.7 6.7 7.7 8.7 9.7 10.7 11.7 12.7 13.7 14.7 15.7

54 1.9 2.9 4.0 5.1 6.1 7.2 8.3 9.3 10.4 11.5 12.6 13.6 14.7 15.8 16.8

60 2.2 3.4 4.6 5.8 7.1 8.3 9.5 10.8 12.0 13.2 14.4 15.7 16.9 18.1 19.3

66 2.4 3.8 5.2 6.6 8.0 9.4 10.8 12.2 13.5 14.9 16.3 17.7 19.1 20.5 21.9

72 2.6 4.0 5.5 6.9 8.4 9.9 11.3 12.8 14.2 15.7 17.2 18.6 20.1 21.5 23.0

78 2.8 4.5 6.1 7.7 9.3 10.9 12.6 14.2 15.8 17.4 19.0 20.7 22.3 23.9 25.5

84 3.1 4.9 6.7 8.5 10.2 12.0 13.8 15.6 17.4 19.1 20.9 22.7 24.5 26.3 28.0

90 3.4 5.3 7.3 9.2 11.2 13.1 15.0 17.0 18.9 20.9 22.8 24.7 26.7 28.6 30.6

96 3.5 5.5 7.5 9.6 11.6 13.6 15.6 17.6 19.6 21.6 23.6 25.7 27.7 29.7 31.7

Free Area (ft2)

Pressure Loss

Louver Test Size = 48" 48" (1219 1219)

Width (Inches)

H ei gh t

(I nc he s)

0.01

0.10

1.00

100 1,000 10,000

Free Area Velocity (fpm)

Selection Criteria Follow the steps listed below to calculate the louver size needed to satisfy the required air volume while minimizing the adverse effects of water penetration and pressure loss.

1. Determine the Free Area Velocity (FAV) at the maximum allowable pressure loss using the Pressure Loss chart to the left. While job conditions vary, typically, the maximum allowable pressure loss should not exceed 0.15 in.wg., and the FAV for

0.15 in.wg. pressure loss is listed on the front page of this sheet.

2. Intake Applications If the FAV at the Beginning Point of Water Penetration (shown below) is less than the FAV from step 1, then use the FAV at the Beginning Point of Water Penetration in step 3, otherwise use the FAV from step 1.

Exhaust Applications Use the FAV from step 1 in step 3.

3. Calculate the total louver square footage required using the following equation.

__________ cfm ÷ __________ fpm = __________ ft2

Required FAV Required Louver (Free-Area) Air Volume Size in ft2

4. Using the Free Area chart above, select a louver width and height that yields a free area ft2 greater than or equal to the required louver size calculated in step 3.

Standard Finish colors for aluminum products and acoustical louvers

El Cajon Silver M-18155 M-19155

Champagne M-18156 M-19156

Light Bronze M-18157 M-19157

Medium Bronze M-18158 M-19158

Dark Bronze M-18159 M-19159

Sandstone M-18139 M-19139

Nantucket Dune M-18140 M-19140

Beige M-18141 M-19141

Seawolf M-18142 M-19142

Fashion Gray M-18143 M-19143

Colonial Gray M-18144 M-19144

Charcoal Gray M-18145 M-19145

Light Blue M-18146 M-19146

Interstate Blue M-18147 M-19147

Aged Copper M-18148 M-19148

Hartford Green M-18149 M-19149

Brick Red M-18150 M-19150

Burgundy M-18151 M-19151

Sage Brown M-18152 M-19152

Statuary Bronze M-18153 M-19153

Black M-18154 M-19154

The color samples shown are not the actual paint. The samples are as close as possible to actual colors offered. Actual coating samples are available upon request.

Please call us at 817-509-2300 or e-mail us at info@pottorff.com to request a sample of our color chart.

The first M number is for the standard Fluoropolymer finish and the second number is for the same color in Polyester.

Premium Pearl colors use mica pigments to simulate the appearance of anodized finishes. The first M number is for the standard Fluoropolymer finish and the second number is for the same color in Polyester.

Premium Pearl finish colors for aluminum products and acoustical louvers

Apollo White M-18136 M-19136

Bone White M-18137 M-19137

Colonial White M-18138 M-19138

Ivory M-18162 M-19162

CChart 04/15

Finishes enhance louver appearance by matching or contrasting with adjacent surfaces and extending weather resistance. Color matching is available upon request.

5101 Blue Mound Road, Fort Worth, Texas 76106 • Phone: 817-509-2300 • Fax: 817-831-3110 • www.pottorff.com • www.alllite.com

Our superior performance paint systems are available in a wide range of colors and we can also custom color match to any of your specifications. Our expertise in applying architectural coatings assures you of a high quality finish. With our color options, you get the color you need when you need it!

PRODUCT FACTS

Finish Type Description/Application Color Selection Warranty 2-coat 100% Fluoropolymer Powder Coat meets AAMA 2605. Dry film thickness 2 mil.

Equivalent to Kynar 500®/Hylar 5000®, Duranar®, Fluoropon®

2-coat Polyester Powder Coat meets AAMA 2604. Dry film thickness 2 mil. Equivalent to Baked Enamel.

Integral Color Anodize AA-M10C22A42 (>0.7 mil)

Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil)

Alkyd Prime Coat

Mill

Our premier finish for extruded aluminum. Tough, long lasting, environmentally friendly powder coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering.

Environmentally friendly powder coating has good color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering.

Electrochemically deposited inorganic color pigment which is sealed to convert an aluminum oxidation into a corrosion resistant finish. Some shade variation will occur.

Electrochemically oxidized aluminum surface for uniform clear finish. More resistant to natural oxidizing. Improved luster and less glossy than mill finish.

Preparation for field applied epoxy, vinyl, urethane, or other heavy-duty coatings. Must be finished within 6 months of application. Contamination can occur in transit and in the field;

requires field cleaning prior to painting.

Aluminum or Galvanized Steel. Normal weathering will occur.

Standard Colors: 20 standard colors plus Premium Pearl finishes. Custom colors are available. Consult factory.

20 standard colors for aluminum products and acoustical louvers, 18 colors for steel. Custom colors are available. Consult factory.

Champagne; Light, Medium or Dark Bronze; Black

Clear

N/A

5 Years (consult factory for availability of extended warranty up to 20 years).

5 Years

MATERIAL APPROVAL SUBMITTAL

(See Instructions on Reverse)

Form Approved OMB No 9000-0062

Expires May 31, 2005

Public reporting burden for this collection of information is estimated to average 20 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to the Department of Defense, Washington Headquarters Services, Directorate for Information Operations and

Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project OMB No 9000-0062, Washington DC 20503. Please DO NOT RETURN your form to either of these addresses. Send your completed form to: SAF/AQCP, 1060 Air Force Pentagon, Washington DC

TO: (Contracting Officer) FROM: (Contractor) DATE

CONTRACT NUMBER SUBMISSION NUMBER SUBMITTAL

PREVIOUS SUBMISSION NUMBER PROJECT NUMBER

TO BE COMPLETED BY CONTRACTOR FOR GOVERNMENT USE ONLY

ITEM

NO.

SPECIFICATION SECTION/

PARA NO./DRAWING NO.

DESCRIPTION OF MATERIAL

(Include Type, Model Number, Catalog Number, Mfg., etc.)

AP-

PROVED

DISAP-

PROVED

SEE

REVERSE

INITIAL

BY COMPLETING THIS FORM, THE UNDERSIGNED CONTRACTOR CERTIFIES THAT

THE MATERIAL COMPLIES WITH ALL SPECIFICATIONS OF SUBJECT CONTRACT.

DATE (YYYYMMDD) TYPE OR PRINT NAME AND GRADE SIGNATURE

FOR GOVERNMENT USE ONLY

TO: (Base Civil Engineering Officer)

For Evaluation and Action RNLT ________________ OR SOONER

TO: (AF Contracting Office)

RECOMMEND APPROVAL DISAPPROVAL AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE

TO: (Contractor)

APPROVED

DISAPROVED AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE SIDE. REQUEST

RESUBMITTAL ON DISAPPROVED ITEMS WITHIN ____ DAYS OF DATE SHOWN BELOW.

AF IMT 3000, 20030901, V1 PREVIOUS EDITION IS OBSOLETE.

New Resubmittal

COMMENTS

(Number to correspond with applicable Item Number on reverse)

INSTRUCTIONS TO CONTRACTORS

1. The term "material" is defined as articles, supplies, raw materials, equipment, parts, components, and end items that are to be incorporated into the work required by the contract.

2. This form is to be used by contractors for submitting Shop Drawings, Equipment Data, Manufacturer's Literature and Certificates and samples of Materials to the Government for approval in accordance with the provisions of this contract. Unless otherwise specified, it is to be prepared in 4 copies, signed, and provided to the contracting officer with appropriate attachments.

3. Item(s) to be approved will be clearly tabbed or identified. Data pertaining to item(s) to be approved will be clearly identified or tabbed, particularly where documents are voluminous, in order to properly evaluate the materials or articles to be incorporated in the work. Each attachment will be numbered to correspond with the item number shown on the face of this form.

4. Requests submitted shall be numbered consecutively, by contract, in the space entitled "Submission No.". This number, in addition to the Contract No., will be used to identify each Material Approval Submittal. Resubmissions will be indicated in the appropriate block and the insertion of previous submission number and data in addition to a new submission number. A single submission should be used for all work of a section of the specifications, but in NO instance should the submission include work for more than one (1) contract. Submittals requiring priority handling will be submitted by separate submittal using the form and so marked across the face of the form.

5. This Material Approval Submittal is not valid unless it is signed by the contracting officer. This approval is required as called for by the contracting officer under the terms of this contract.

AF IMT 3000, 20030901, V1 (REVERSE)

TO Contracting Officer: SrA Vitaliy Poprozhuk

FROM Contractor: FARR Builders LLC S. Gevers, San Antonio, TX 78210

DATE: 03 January 2017

CONTRACT NUMBER: FA4661-15-D-0001

SUBMISSION NUMBER: 22

PREVIOUS SUBMISSION NUMBER: 21

PROJECT NUMBER: FNWZ 12-0053

ITEM NORow1: 1

SPECIFICATION SECTION PARA NODRAWING NORow1: Per Sow

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow1: Lovers and color chart

INITIALRow1: PR

ITEM NORow2:

SPECIFICATION SECTION PARA NODRAWING NORow2:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow2: Statuary Bronze Color

INITIALRow2: PR

ITEM NORow3:

SPECIFICATION SECTION PARA NODRAWING NORow3:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow3:

INITIALRow3:

ITEM NORow4:

SPECIFICATION SECTION PARA NODRAWING NORow4:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow4:

INITIALRow4:

ITEM NORow5:

SPECIFICATION SECTION PARA NODRAWING NORow5:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow5:

INITIALRow5:

ITEM NORow6:

SPECIFICATION SECTION PARA NODRAWING NORow6:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow6:

INITIALRow6:

ITEM NORow7:

SPECIFICATION SECTION PARA NODRAWING NORow7:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow7:

INITIALRow7:

ITEM NORow8:

SPECIFICATION SECTION PARA NODRAWING NORow8:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow8:

INITIALRow8:

ITEM NORow9:

SPECIFICATION SECTION PARA NODRAWING NORow9:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow9:

INITIALRow9:

ITEM NORow10:

SPECIFICATION SECTION PARA NODRAWING NORow10:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow10:

INITIALRow10:

ITEM NORow11:

SPECIFICATION SECTION PARA NODRAWING NORow11:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow11:

INITIALRow11:

DATE YYYYMMDD: 2017-10-30

TYPE OR PRINT NAME AND GRADE: Wayne Owens, Project Supt.

TO Base Civil Engineering Officer: 502 CE

RNLT:

DATE YYYYMMDD_2: 20180109

TYPE OR PRINT NAME AND GRADE_2: Yeongsoo Jeon, A1C

TO AF Contracting Office: 7 CONS

DATE YYYYMMDD_3: 20180105

TYPE OR PRINT NAME AND GRADE_3: Patrick Rolan, GS-12

TO Contractor: FARR Builders LLC

DATE YYYYMMDD_4: 20180109

TYPE OR PRINT NAME AND GRADE_4: Capt Hilary Ince

2018-01-09T08:19:00-0600

JEON.YEONGSOO.1538040130

2018-01-05T16:19:52-0600

ROLAN.PATRICK.M.1515150249

2018-01-09T08:40:39-0600

INCE.HILARY.RAE.1368173785

Text5:

Check Box6: Yes

Check Box7: Off

Check Box8: Off

Check Box9: Yes

Check Box10: Off

Check Box11: Off

Check Box12: Off

Check Box13: Off

Check Box14: Off

Check Box15: Off

Check Box16: Off

Check Box17: Off

Check Box18: Off

Check Box19: Off

Check Box20: Off

Check Box21: Off

Check Box22: Off

Check Box23: Off

Check Box24: Off

Check Box25: Off

Check Box26: Off

Check Box27: Off

Check Box28: Off

Check Box29: Off

Check Box30: Off

Check Box31: Off

Check Box32: Off

Check Box33: Off

Check Box34: Off

Check Box35: Off

Check Box36: Off

Check Box37: Off

Check Box38: Off

Check Box3: Yes

Check Box4: Yes

Check Box5: Off

Check Box40: Off

COMMENTS Number to correspond with applicable Item Number on reverseRow1:

Check Box39: Yes

Check Box50: Off

File details come from the government source that posted it. Updated .